Survivair Panther SCBA - Lakeside Fire Protection · PDF fileSurvivair Survivair Panther SCBA...

Click here to load reader

  • date post

    04-Jun-2018
  • Category

    Documents

  • view

    224
  • download

    2

Embed Size (px)

Transcript of Survivair Panther SCBA - Lakeside Fire Protection · PDF fileSurvivair Survivair Panther SCBA...

  • SurvivairSurvivair Panther SCBAPanther SCBAOpenOpen--Circuit, PressureCircuit, Pressure--DemandDemandIntegrated PASSIntegrated PASSAir GaugeAir GaugeBuddy BreatherBuddy BreatherFullFull--Wrap Carbon CylinderWrap Carbon CylinderUniversal Air Connection (UAC)Universal Air Connection (UAC)

  • SurvivairSurvivair Panther SCBAPanther SCBAMightyLightMightyLight BackpackBackpack

    Lightweight polymer frame with carrying Lightweight polymer frame with carrying handleshandles

    Kevlar/Kevlar/NomexNomex strapsstrapsCylinder attached with webbingCylinder attached with webbing--style bandstyle band

  • SurvivairSurvivair Panther SCBAPanther SCBACYLINDER (CYLINDER (LuxferLuxfer))

    Composite construction with aluminum inner Composite construction with aluminum inner liner liner overwrappedoverwrapped with carbonwith carbon

    4500 psig, 45 4500 psig, 45 cu.ftcu.ft. capacity, 30 min.. capacity, 30 min.55--year Hydro requirementyear Hydro requirement

  • SurvivairSurvivair Panther SCBAPanther SCBACylinder Valve AssemblyCylinder Valve Assembly

    Valve assembly has rubberValve assembly has rubber--coated wheel and coated wheel and locking collarlocking collar

    Frangible disc (7500 Frangible disc (7500 psipsi) (5/3 working pressure)) (5/3 working pressure)

  • SurvivairSurvivair Panther SCBAPanther SCBAFIRSTFIRST--STAGE REGULATORSTAGE REGULATOR

    Pressure Reducer, Audible Alarm, Pressure Reducer, Audible Alarm, Intermediate Pressure HoseIntermediate Pressure Hose

    Reduces cylinder pressure to approx. 100psigReduces cylinder pressure to approx. 100psigAudible alarm activates @ 1215 to 1035 psigAudible alarm activates @ 1215 to 1035 psigAlarm sounds until below 200 psigAlarm sounds until below 200 psig

  • SurvivairSurvivair Panther SCBAPanther SCBAUNIVERSAL AIR CONNECTION (UAC)UNIVERSAL AIR CONNECTION (UAC)

    Means for filling SCBA during a rescueMeans for filling SCBA during a rescueDust plugDust plugRelief valve prevents Relief valve prevents overpressurizationoverpressurization

  • SurvivairSurvivair Panther SCBAPanther SCBASECONDSECOND--STAGE REGULATORSTAGE REGULATOR

    PressurePressure--demand (approx .5psi)demand (approx .5psi)AIR KLIC AIR KLIC locking systemlocking systemFirstFirst--BreathBreath--On On oror manual override buttonmanual override buttonBypass valve (counterclockwise for airflow)Bypass valve (counterclockwise for airflow)ShutShut--off buttonoff button

  • SurvivairSurvivair Panther SCBAPanther SCBAHEADSHEADS--UP DISPLAY (HUD)UP DISPLAY (HUD)Mounted on Second stage regulatorMounted on Second stage regulatorFour green Four green LEDsLEDs: full, : full, , , , , Below 50% capacity, Below 50% capacity, LED flashesLED flashesBelow 25% capacity, Below 25% capacity, LED turns red andLED turns red and

    flashes (1215 to 1035 psig)flashes (1215 to 1035 psig)External red LED on front of HUD flashes whenExternal red LED on front of HUD flashes when

    LED flashesLED flashesExternal LED flashes noticeably faster at 10%External LED flashes noticeably faster at 10%

    capacitycapacityPhoto diode on HUD adjusts intensity of Photo diode on HUD adjusts intensity of LEDsLEDs

  • SurvivairSurvivair Panther SCBAPanther SCBATRANSDUCER MODULETRANSDUCER MODULE

    BatteryBattery--poweredpoweredSenses cylinder pressure and generates Senses cylinder pressure and generates

    electronic signal to HUD moduleelectronic signal to HUD moduleAmber LED battery indicator flashes once everyAmber LED battery indicator flashes once every

    10 10 secssecs. to indicate usable battery condition. to indicate usable battery conditionLED flashing every 2 LED flashing every 2 secssecs. indicates low battery. indicates low batteryNo flashing indicates dead batteryNo flashing indicates dead battery

  • SurvivairSurvivair Panther SCBAPanther SCBAFACEPIECEFACEPIECETwenty Twenty TwentyTwenty Plus Plus

    HeadnetHeadnet HarnessHarnessSiliconeSiliconeNose CupNose CupSpeaking DiaphragmSpeaking DiaphragmExhalation valveExhalation valveAIR KLICAIR KLIC

    AbrasionAbrasion--resistant lens coatingresistant lens coating

  • SurvivairSurvivair Panther SCBAPanther SCBASmallTalkSmallTalk Plus Plus Voice Projection System (VPS)Voice Projection System (VPS)Two Operational Modes:Two Operational Modes:Constant On ModeConstant On Mode

    Push button on top of amplifier twice w/in 2 Push button on top of amplifier twice w/in 2 secssecs.;.;The LED will light; speak into the The LED will light; speak into the facepiecefacepiece..Push button twice w/in 2 Push button twice w/in 2 secssecs. to turn off VPS.. to turn off VPS.If no voice input detected in 20 If no voice input detected in 20 minsmins., VPS ., VPS

    automatically shuts off.automatically shuts off.

  • SurvivairSurvivair Panther SCBAPanther SCBASmallTalkSmallTalk Plus Plus Voice Projection System (VPS)Voice Projection System (VPS)PushPush--toto--talk Modetalk Mode

    Push down button on top of amplifier until LED Push down button on top of amplifier until LED lights; speak into lights; speak into facepiecefacepiece..Release button to turn off amplifier.Release button to turn off amplifier.

    If LED does not light, verify battery is installed correctly otherwise replace battery (9v).

    If LED flashes, VPS battery is low and should be replaced.

  • SurvivairSurvivair Panther SCBAPanther SCBACHEST MOUNTED GAUGE &CHEST MOUNTED GAUGE &BUDDY BREATHERBUDDY BREATHER

    Mounted on R shoulder strapMounted on R shoulder strapFemale and male quick disconnect fittings withFemale and male quick disconnect fittings with

    dust capsdust caps

  • SurvivairSurvivair Panther SCBAPanther SCBACOMPASSCOMPASS INTEGRATED PASSINTEGRATED PASSConnected to First stage regulatorConnected to First stage regulatorAutomatic pneumatic activation when SCBA is Automatic pneumatic activation when SCBA is

    pressurizedpressurized

    ACTIVATION:ACTIVATION:Auto Auto when SCBA is pressurizedwhen SCBA is pressurizedManual Manual when SCBA not pressurized, press when SCBA not pressurized, press

    manual switch oncemanual switch once

  • SurvivairSurvivair Panther SCBAPanther SCBACOMPASSCOMPASS INTEGRATED PASSINTEGRATED PASS

    DEACTIVATION:DEACTIVATION:Cylinder valve closed, pressure bled to 0 Cylinder valve closed, pressure bled to 0 psipsi;;

    manual switch pressed two distinct times w/inmanual switch pressed two distinct times w/intwo secondstwo seconds

    OPERATIONAL MODES:OPERATIONAL MODES:Sensing Sensing motion sensor activates premotion sensor activates pre--alarm alarm

    when no motion detected for 30when no motion detected for 30--35 35 secssecs..PrePre--Alarm Alarm sounds 10sounds 10--13 13 secssecs. before alarm;. before alarm;

    will reset to sensing mode with motionwill reset to sensing mode with motionAlarm Alarm repeating tone (95dBA)repeating tone (95dBA)

  • SurvivairSurvivair Panther SCBAPanther SCBACOMPASSCOMPASS INTEGRATED PASSINTEGRATED PASS

    ALARMS & SIGNALSALARMS & SIGNALSCombination of sounds and Combination of sounds and LEDsLEDsActuation (tones & Actuation (tones & LEDsLEDs))Sensing mode (Sensing mode (LEDsLEDs))PrePre--Alarm (dual tone & Alarm (dual tone & LEDsLEDs))Alarm (continuous repeating tone & Alarm (continuous repeating tone & LEDsLEDs))Low Battery (single tone every 20 Low Battery (single tone every 20 secssecs. w/ . w/

    amber low battery LED)amber low battery LED)

    Survivair Panther SCBASurvivair Panther SCBASurvivair Panther SCBASurvivair Panther SCBASurvivair Panther SCBASurvivair Panther SCBASurvivair Panther SCBASurvivair Panther SCBASurvivair Panther SCBASurvivair Panther SCBASurvivair Panther SCBASurvivair Panther SCBASurvivair Panther SCBASurvivair Panther SCBASurvivair Panther SCBASurvivair Panther SCBA