3 IGNITION PROTECTION CATEGORIES Ignition Protection Categories I.D. Can Be Used In Safety Principle Increased safety Ex e Zone 1 No arcs, sparks or hot surfaces Non-sparking equipment Ex nA Zone 2 Pressurized encapsulation Ex d Zone 1 Controls an internal explosion and extinguishes the flame Junction Box Motor 6 CONDITIONS & SUBDIVISIONS Flammable Materials Temporary Behavior of Explosive Atmosphere Classification of Hazardous Areas Group as Defined in Directive 94/9/EC Equipment Category as Defined in Directive 94/9/EC Equipment Group as Defined in EN 60079-O Equipment Protection Level (EPL) as Defined in EN 60079-O Gases/ Vapors is present continuously or for long periods or frequently Zone 0 II 1G II Ga arises in normal operation occasionally Zone 1 II 2G or 1G II Gb or Ga is not likely to arise in normal operation, or if it does, will persist for a short time only Zone 2 II 3G or 2G or 1G II Gc or Gb or Ga 5 TEMPERATURE CLASSES Class T1 T2 T3 T4 T5 T6 MAXIMUM SURFACE TEMPERATURE 450ºC 300ºC 200ºC 135ºC 100ºC 85ºC IIA Acetone Ammoniac Benzene Acetic Acid Ethane Ethyl Acetate Ethyl Chloride Methane Methanol Naphthalene Phenol Propane i-Amylacetate n-Butane n-Butyl Alcohol Gasolines Diesel Fuels Heating Oils n-Hexane Acetyl- dehyde IIB Town gas (lighting gas) Ethylene Ethylene Oxide Hydrogen Sulfide Ethylether Gas Group IIB, Class t6 includes all specifications for Gas Group IIA, Class T1-T6 and Gas Group IIB, T1-T6 Hazardous Workplace Safety Manufacturer of RAMFAN Portable Ventilators Portable Ventilation Solutions for Dangerous Environments USA / Luxembourg / China / UAE [email protected] www.EuramcoSafety.com Toll Free (800) 472-6372 USA +1 (619) 670-9590 Luxembourg +352-26008055 Highlighted areas in chart apply to Euramco Safety’s ATEX certification © 2016 Euramco Safety, Inc. CERTIFICATIONS IECEx UL Certificate #: 13.0062X EC-Type Examination Certificate #: DEMKO 09 ATEX 0926969X INMETRO Certificate #: UL-BR 13.0593X CE Hazardous Location Marking: CE0539 Ingress Protection: IP55 Zone 1 Zone 2 Zone 0 Zone 1 Zone 2 Zone 0 Zone 0 020116 ATEX EXPLAINED I Ex de T6 S II 2 G Ex de IIB T6 Gb Ignition Protection Category Gas Group IIB Temperature Class Conditions & Subdivisions Gb Equipment Group II Equipment Category 2 Hazard G ATEX TR NG 1 1 2 3 4 6 5 Gas Group IIB includes all gases for Group IIA 4 GAS GROUPS Gas Group Representative Test Gas IIA Propane IIB Ethylene EQUIPMENT GROUP & CATEGORY Equipment Equipment Protection Hazard Group Category Level Gas Dust Use II - Industrial 1 Very high G Zones 0, 1, 2 (non-Mining) protection D Zones 20, 21, 22 2 High G Zones 1, 2 protection 1 CLASSIFICATION OF HAZARDOUS AREAS Area Classification Gases Dusts Zone Criteria (based on frequency and duration) Zone 0 Potentially Explosive substance present Zone 20 continuously or for long periods >1000hrs/yr Zone 1 Potentially Explosive substance likely to be Zone 21 present in normal operation >10hrs <1000hrs/yr Zone 2 Potentially Explosive substance unlikely to be Zone 22 present in normal operation, if it does will only be for short periods <10hrs/yr 2

Transcript of ATEX EXPLAINED - Krop

Page 1: ATEX EXPLAINED - Krop

3 IGNITION PROTECTION CATEGORIES

Ignition Protection Categories I.D. Can Be Used In Safety Principle

Increased safety Ex e Zone 1 No arcs, sparks or hot surfacesNon-sparking equipment Ex nA Zone 2

Pressurized encapsulation Ex d Zone 1 Controls an internal explosion and extinguishes the flame

Junc

tio

nB

oxM

oto

r

6 CONDITIONS & SUBDIVISIONS

FlammableMaterials

Temporary Behaviorof Explosive Atmosphere

Classificationof HazardousAreas

Group as Defined in Directive 94/9/EC

Equipment Category as Defined in Directive 94/9/EC

EquipmentGroup as Defined in EN 60079-O

Equipment Protection Level (EPL) as Defined in EN 60079-O

Gases/ Vapors

is present continuously orfor long periods or frequently

Zone 0 II 1G II Ga

arises in normaloperation occasionally

Zone 1 II 2G or 1G II Gb or Ga

is not likely to arise in normal operation, or if it does, will persist for a short time only

Zone 2 II 3G or2G or 1G

II Gc orGb or Ga

5 TEMPERATURE CLASSESClass T1 T2 T3 T4 T5 T6

MAXIMUM SURFACE TEMPERATURE

450ºC 300ºC 200ºC 135ºC 100ºC 85ºCIIA Acetone

Ammoniac Benzene Acetic Acid Ethane Ethyl Acetate Ethyl Chloride Methane Methanol Naphthalene Phenol Propane

i-Amylacetate n-Butane n-Butyl Alcohol

Gasolines Diesel Fuels Heating Oils n-Hexane

Acetyl-dehyde

– –

IIB Town gas (lighting gas)

Ethylene Ethylene Oxide

Hydrogen Sulfide

Ethylether – –

Gas Group IIB, Class t6 includes all specifications for Gas Group IIA, Class T1-T6 and Gas Group IIB, T1-T6

Hazardous Workplace Safety

Manufacturer of RAMFAN Portable Ventilators

Portable Ventilation Solutions for Dangerous Environments

USA / Luxembourg / China / [email protected]

Toll Free (800) 472-6372USA +1 (619) 670-9590 Luxembourg +352-26008055

Highlighted areas in chart apply to Euramco Safety’s ATEX certification

© 2

016

Eura

mco

Saf

ety,

Inc.

CERTIFICATIONSIECEx UL Certificate #: 13.0062XEC-Type Examination Certificate #: DEMKO 09 ATEX 0926969XINMETRO Certificate #: UL-BR 13.0593XCE Hazardous Location Marking: CE0539Ingress Protection: IP55

Highlighted areas in charts apply to Euramco Safety’s ATEX Certification String

Zone 1

Zone 2

Zone 0Zone 1Zone 2

Zone 0

Zone 0

0201

16

ATEX EXPLAINED

I

Ex de T6

S II 2 G Ex de IIB T6 GbIgnition Protection

Category

Gas GroupIIB

TemperatureClass

Conditions &Subdivisions

Gb

Equipment Group IIEquipment Category 2

Hazard G

ATEXTR NG

1

12

3

46

5

Gas Group IIB includes all gases for Group IIA

4 GAS GROUPS

Gas Group Representative Test Gas IIA PropaneIIB Ethylene

EQUIPMENT GROUP & CATEGORY

Equipment Equipment Protection HazardGroup Category Level Gas Dust UseII - Industrial 1 Very high G – Zones 0, 1, 2(non-Mining) protection – D Zones 20, 21, 22

2 High G – Zones 1, 2protection

1 CLASSIFICATION OF HAZARDOUS AREAS

Area Classification Gases Dusts Zone Criteria (based on frequency and duration)Zone 0 – Potentially Explosive substance present

– Zone 20 continuously or for long periods >1000hrs/yrZone 1 – Potentially Explosive substance likely to be

– Zone 21 present in normal operation >10hrs <1000hrs/yrZone 2 – Potentially Explosive substance unlikely to be

– Zone 22 present in normal operation, if it does will onlybe for short periods <10hrs/yr

2

Page 2: ATEX EXPLAINED - Krop

ELECTRIC BLOWERS

UB20xx 8" (20 cm) Blower/Exhauster

Worldwide Certified Explosion-Proof Ventilators

Some units don’t include plugs. Please inquire for options.

RAMFAN Hazardous location fans are used in many different industries including: Petrochemical, chemical, marine, pharmaceutical, wastewater, natural gas utility, aircraft maintenance and confined space entry in hazardous locations.

AIR DRIVEN BLOWERS

UB20xx M.E.D.™Manhole Entry Device

The explosion-proof UB20xxSystem utilizes high strengthpolymers with an anti-statichousing designed to dischargestatic build-up safely. The M.E.D.™allows workers to enter and exitsmall man-size openings whilemaintaining continuous ventilation. Without such a device, duct fills the manhole opening, preventing rapid entry and exit. Tightly integrated into the UB-line of confined space ventilation equipment, the RAMFAN M.E.D.™ is quick to assemble and the new swiveling elbow makes duct alignment easy.

DUCTED AIRFLOW (cfm)/(m³/hr)

AIRFLOW (cfm)/(m³/hr)

Euramco Safety has designed and manufactured a line of fans specifically for use in hazardous atmospheres to meet the standards specified by the ATEX Directive 94/9/EC, IECEx, CE, INMETRO and UL. Our certifications cover the whole unit: the motor, terminal box, power cable, fan blade and labeling.

These Standards apply to all electrical equipment to prevent or minimize potential source of ignition in hazardous gas, or vapor atmospheres, to the extent defined in the charts on back page.

The chart on the back cover explains the ATEX Identification Numbering System. Look for the whole-unit ATEX Certification string on RAMFAN Products.

EF7015 115V Blower w/ Canister, 15' (4.6m) duct 789/1341 666/1132

EF7025 115V Blower w/ Canister, 25' (7.6m) duct 722/1227 614/1044

EF8015 230V Blower w/ Canister, 15' (4.6m) duct 659/1120 557/947

EF8025 230V Blower w/ Canister, 25' (7.6m) duct 603/1025 510/867

Order# Description(1) 90˚

Duct Band(2) 90˚

Duct Band

AB7000 12" (30cm) Blower/Exhauster 39/18 2042/3471@80psi

40/68

Order# DescriptionShip Wt. (Ibs/kg)

Free Air (cfm) (m³/hr)

Air Consumption (cfm) (m³/hr)

EA8000XX** (EFi50xx)

16" (40cm) Blower/Exhauster115V, 50/60Hz

0.5 51/233200/5440

@60Hz

EA8120XX* (EFi120xx)

16" (40cm) Blower/Exhauster240V, 50/60Hz

1.2 58/263750/6375

@50Hz

EG8200XX* (EFi150xx)

16" (40cm) Blower/Exhauster115V, 50/60Hz

1.5 62/284459/7580

@60Hz

EG8200XX-230* (EFi150xx)

16" (40cm) Blower/Exhauster230V, 50/60Hz

1.5 62/284459/7580

@60Hz

Order# Description HpShip Wt. (Ib/kg)

Free Air (cfm) (m³/hr)

RV760S Venturi 3" (76mm) Cone (short) 6/3

RV760 Venturi 3" (76mm) Cone 7/3

RV760S Venturi 6" (152mm) Cone 17/8

AZ-RAC-10 Grounding Clamp 2/1

Order# Description Ship Weight (Ibs/kg)

AA7000 16" (40cm) Blower/Exhauster 48/22 3200/5440 @80psi

40/68

Ship Wt. (Ibs/kg)Order# Description

Free Air (cfm) (m³/hr)

Air Consumption (cfm) (m³/hr)

Order# Description HpShip Wt. (Ibs/kg)

Free Air (cfm) (m³/hr)

EF7002* 8" (20cm) Blower/Exhauster115V, 50/60Hz

1/3 25/11980/1,666

@60Hz

EF8002* 8" (20cm) Blower/Exhauster230V, 50/60Hz

1/4 25/11819/1,392

@50Hz

*Whole unit certification: See back page for certification string

EB7201XX* 12" (30cm) Blower/ Exhauster 115V, 50/60Hz

3/4 58/262500/4250

@60Hz

EB7201XX-230* 12" (30cm) Blower/ Exhauster 230V, 50/60Hz

3/4 58/262500/4250

@60Hz

Order# Description HpShip Wt. (Ibs/kg)

Free Air (cfm) (m³/hr)

*Whole unit certification: See back page for cert string

*Whole Unit Certification see back page for certification string. **Motor Certfication No. UL E312535, CSA LR66789EA8120XX Motor NO. 1223007401EG8200XX/EG8200-230 Motor NO. 1133007417

DescriptionShip Wt. (Ibs/kg)

Conductive DuctingReinforced, anti-static duct safely conducts static electricity to the ground circuit of the blower. All duct materials are flame retardant.

Order#

FDT-0815CBB 8" (20cm) reinforced duct 15' (4.6m ) + bag 10/5

FDT-0825CBB 8" (20cm) reinforced duct 25' (4.6m ) + bag 14/6

FDT-1215CBB 12" (30cm) reinforced duct 15' (4.6m ) + bag 14/6

FDT-1225CBB 12" (30cm) reinforced duct 25' (7.6m ) + bag 19/9

FDT-1615CBR 16" (40cm) reinforced duct 15' (4.6m ) + bag 26/12

FDT-1625CBR 16" (40cm) reinforced duct 25' (4.6m ) + bag 33/15

BG8 8" (20cm) duct bag 2/1

BG12 12" (30cm) duct bag 2/1

BG16 16" (40cm) duct bag 2/1

EF7015-MEDXX

8" (20cm) 115V Blower/Exhauster, Quick-CoupleTM

Canister w/ 15' (4.6m) & 5' (1.5m) of duct, Manhole Entry Device, 90° Swivel Elbow & Universal Mount

51/23

EF8015-MEDXX

8" (20cm) 230V Blower/Exhauster, Quick-CoupleTM

Canister w/ 15’ (4.6m) & 5' (1.5m) of duct, Manhole Entry Device, 90° Swivel Elbow & Universal Mount

51/23

Order# DescriptionShip Wt. (Ibs/kg)

Free Air Consumption

Air Consumption

Free Air Consumption

Air Consumption

RV760S 22/37 58/99 810/1377 1180/2006

RV760 22/37 58/99 1001/1702 1439/2446

RV1500 59/100 124/211 2740/4658 3329/5659

Order#

40sig Inlet Pressure 80psig Inlet Pressure

EFi50xx /EFi120xx/EFi150xx16" (40 cm) Blower/ExhausterRugged and Reliable

Motor is totally enclosed for use in hazardous locations. Supply and exhaust hazardous/explosive gases safely. High strength, anti-static glass reinforced ABS housing is lightweight, corrosion-proof

and chemical resistant. IP55 splash tested switch enclosure and integral duct adapters. Stackable for ventilation of larger areas and easy storage.

LR66789

EFi50XX

Powerful, Compact Size and Lightweight

Hazardous location blower with totally enclosed motor is safe for use in a variety of adverse atmospheres. Super compact and lightweight while deliv-ering the highest CFM available in its class. Tough, chemical resistant, anti-static housing for hazardous conditions. Ultra-quiet operation at 74 dB. Power cable is 25' (7.6 m) long.

Optional anti-static Quick-CoupleTM Can-ister stores and protects duct from rips and tears. Intergrated into the UB20xx blower for fast and convenient set-up. Use with fan for exhaust or suction. Available with either 15' (4.6 m) or 25' (7.6 cm) of duct.

RV760S/RV760/RV1500Venturi ConesAir or Saturated Steam Driven

Pneumatic (compressed air)or saturated steampowered venturi conesfor safe use in adverse orexplosive atmosphereswhen used with optionalstatic grounding cord. Cones arecrush and dent resistant. Cylindricalmixing chamber delivers higherinduction ratios and fits standard API 3" (7 cm)and 6" (15 cm) openings. Requires minimum maintenance.

AFi50xx 16" (40 cm)Blower/ExhausterStackable Air Driven Ventilator

High Strength, anti-static ABS housing with two integral 16" (40 cm) duct adapters is lightweight, corrosion proof and chemical resistant. Exhausts outside of duct, compressed air not in airstream. Comes complete with filter, motor lubricator, exhaust muffler, air control valve and static grounding cord.

AFi75xx 12" (30 cm)Blower/ExhausterCompact, Air Driven Ventilator

Hazardous location blower for use in adverse atmospheres. Pneumatic Motor exhausts outside of duct, compressed air is not in airstream. Complete with filter, motor lubricator, exhaust muffler, air control valve, static grounding cord and 12" (30 cm) duct adapters.

EFi75xx 12" (30 cm) Blower/ExhausterDual Voltage, Dual Frequency

Supply and exhaust hazardous/explo-sive gases safely. Flame-proof motor, 100% duty cycle TEAO. Tough, chemical resistant ABS housing is carbon-filled

to conduct static charges to ground. IP55 splash tested switch enclosure “watertight” and integral 12" (30 cm) duct adapters. Reliable, rugged and versatile.

PipelineRepair / Replacement

Ventilation & Fume Displacement

Cleaning & Ventilation

TransportationCleaning / Maintenance

Equipment Cooling Ship HullCleaning / Repair / Maintenance

Tank ResurfacingRepair / Maintenance Tank Cleaning

Offshore

Onshore

Ventilation Scenarios