RW West Consultants, Inc. Property Inspection Report Inspector: Clifton Moody (Skip), RW West Consultants, Inc. Cover Page 11735 SE 78th Pl, Newcastle, WA 98056 Inspection prepared for: Faira .com Real Estate Agent: - Date of Inspection: 5/30/2019 Time: 9:00 AM Age of Home: 1989 Size: 1900 This inspection and report is exactly the same as it would be you the buyer had ordered the report directly from us. We have performed over 20,000 inspections for home buyers over 32 years. Please check out our reviews on google what buyers that we have worked for think about our services. It is the quality of inspections that has earned buyers and Fairas’ trust in providing a completely unbiased report. Faira gives us no special instructions on how we perform our inspections. These reports are exactly the same reports as we would have produced if you had hired us on that day. If you are a buyer and have questions, please call us at 425-0885-0722 and we can go over the report. Our inspectors can also revisit/reinspect the property with the prospective buyer and their agent, reinspect any repairs or update the sellers might have done, after the original inspection date for $200 reinspection fee. Front Faces North Inspector: Clifton Moody (Skip) License # 957 Email: [email protected]

Transcript of RW West Consultants, Inc....2019/05/30  · RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle,...

Page 1: RW West Consultants, Inc....2019/05/30  · RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA Page 2 of 54 Inspection Details We appreciate the opportunity to conduct this

RW West Consultants, Inc.Property Inspection Report

Inspector: Clifton Moody (Skip), RW West Consultants, Inc.

Cover Page

11735 SE 78th Pl, Newcastle, WA 98056Inspection prepared for: Faira .com

Real Estate Agent: -

Date of Inspection: 5/30/2019 Time: 9:00 AM Age of Home: 1989 Size: 1900

This inspection and report is exactly the same as it would be you the buyer had ordered the reportdirectly from us. We have performed over 20,000 inspections for home buyers over 32 years. Pleasecheck out our reviews on google what buyers that we have worked for think about our services. It is

the quality of inspections that has earned buyers and Fairas’ trust in providing a completely unbiasedreport. Faira gives us no special instructions on how we perform our inspections. These reports are

exactly the same reports as we would have produced if you had hired us on that day.If you are a buyer and have questions, please call us at 425-0885-0722 and we can go over thereport. Our inspectors can also revisit/reinspect the property with the prospective buyer and their

agent, reinspect any repairs or update the sellers might have done, after the original inspection datefor $200 reinspection fee.

Front Faces North

Inspector: Clifton Moody (Skip)License # 957

Email: [email protected]

Page 2: RW West Consultants, Inc....2019/05/30  · RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA Page 2 of 54 Inspection Details We appreciate the opportunity to conduct this

RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA

Page 3: RW West Consultants, Inc....2019/05/30  · RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA Page 2 of 54 Inspection Details We appreciate the opportunity to conduct this

RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA

Page 2 of 54

Inspection Details We appreciate the opportunity to conduct this inspection for you!   Please carefully read your entireInspection Report.  Call us after you have reviewed your report, so we can go over any questionsyou may have.  Remember, when the inspection is completed and the report is delivered, we are stillavailable to you for any questions you may have, throughout the entire closing process.Properties being inspected do not "Pass" or "Fail.” -  The following report is based on an inspectionof the visible portion of the structure; inspection may be limited by vegetation and possessions. Depending upon the age of the property, some items like GFI outlets may not be installed;For your safety and liability purposes, we recommend that licensed contractors evaluate and repairany critical concerns and defects.  Note that this report is a snapshot in time. We recommendthat you or your representative carry out a final walk-through inspection immediately beforeclosing to check the condition of the property, using this report as a guide. Items denote serious, safety or items that required further investigationItems denote minor or maintenance itemsGreen notes denote locations and shutoff valves

1. AttendanceIn Attendance: No other parties present at inspection.

2. Home TypeHome Type: Single Family Home

3. OccupancyOccupancy:• Vacant

Page 4: RW West Consultants, Inc....2019/05/30  · RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA Page 2 of 54 Inspection Details We appreciate the opportunity to conduct this

RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA

Page 3 of 54

General Exterior Note 1. Exterior NoteObservations:• North Elevation• South Elevation• East Elevation• West Elevation

North Elevation East Elevation

South Elevation West Elevation

Page 5: RW West Consultants, Inc....2019/05/30  · RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA Page 2 of 54 Inspection Details We appreciate the opportunity to conduct this

RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA

Page 4 of 54

Exterior Areas 1. Siding ConditionSiding appeared in good condition overall. • Wood siding. • Brick siding

2. GuttersGutters and downspouts appeared in good condition overall.

3. Driveway and Walkway ConditionConcrete sidewalks and/or driveways appeared in good condition overall.

Page 6: RW West Consultants, Inc....2019/05/30  · RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA Page 2 of 54 Inspection Details We appreciate the opportunity to conduct this

RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA

Page 5 of 54

4. SoffitSoffits and eaves appeared in good condition overall.

5. Door/WindowExterior doors appeared in operable condition, at time of inspection. • Window frames and sillsappeared in good condition overall.

6. GradingGrading appeared in good condition overall.

7. ElectricalExterior outlets operate overall • Exterior lights attached to the house operate overall.Observations:• GFCI outlets have been required at exterior (since 1973) No GFCI protection present at northside. strongly recommend GFCI outlets are installed as a safety precaution.

8. Cable FeedsMaterials: Primary Service is Underground Service Lateral

9. Gas ConditionMeter located at west side. Main Gas shutoff is located to the lower left of the meter.

Definition
A special device that is intended for the protection of personnel by de-energizing a circuit, capable of opening the circuit when even a small amount of current is flowing through the grounding system.
Page 7: RW West Consultants, Inc....2019/05/30  · RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA Page 2 of 54 Inspection Details We appreciate the opportunity to conduct this

RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA

Page 6 of 54

10. Exterior Faucet ConditionExterior faucets were in operable condition overall.Observations:• Hose bib at south side of house leaks.• Sometimes tightening packing nut will remedy this condition.

11. Pressure85Observations:• Water pressure is in excess of 80 PSI. Water pressure above 80 PSI can result in plumbing leaksand cause plumbing appliances to wear more quickly, recommend adjusting water pressure orinstalling pressure reducing valve.

Page 8: RW West Consultants, Inc....2019/05/30  · RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA Page 2 of 54 Inspection Details We appreciate the opportunity to conduct this

RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA

Page 7 of 54

Exterior Stairs 1. StairSteps appeared uniform.

Page 9: RW West Consultants, Inc....2019/05/30  · RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA Page 2 of 54 Inspection Details We appreciate the opportunity to conduct this

RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA

Page 8 of 54

Roof 1. Roof ConditionArchitectural Composition shingle. • Roof surface is appeared in good condition overall. • Walkedon roof surface.Type Average life span 40 years for this type surface with proper maintenance and care.

Page 10: RW West Consultants, Inc....2019/05/30  · RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA Page 2 of 54 Inspection Details We appreciate the opportunity to conduct this

RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA

Page 9 of 54

2. ChimneyMetal Chimney with siding/ enclosure • Gas B vent appeared in good condition overall, B ventheight was adequate overall.Observations:• Some corrosion to metal chimney crown, recommend painting with a rust retardant

Page 11: RW West Consultants, Inc....2019/05/30  · RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA Page 2 of 54 Inspection Details We appreciate the opportunity to conduct this

RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA

Page 10 of 54

Attic 1 1. AtticGarage is location of access.

2. FramingObservations:• Slight darkened coloration that possibly could be a fungal/mold growth in a number or areas.Conditions are generally a result of excessive moisture at some point or inadequate ventilation.Treating/remediation and correction moisture conditions will help prevent future occurrences.Testing would need to be performed to determine the presence or absence of Mold. Testing mayinclude surface sampling and air quality testing.

Page 12: RW West Consultants, Inc....2019/05/30  · RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA Page 2 of 54 Inspection Details We appreciate the opportunity to conduct this

RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA

Page 11 of 54

3. VentilationUnder eave soffit inlet vents noted. • Roof surface vents present.

4. Fan/DuctObservations:• Not All Bathroom fans exhaust completely to the exterior. Typically piping should actually connectto exterior vent, recommend correction. This condition can result in mold/fungal growth.

Page 13: RW West Consultants, Inc....2019/05/30  · RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA Page 2 of 54 Inspection Details We appreciate the opportunity to conduct this

RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA

Page 12 of 54

5. ElectricalObservations:• Electrical switch/Junction Box Covers missing or damaged, which is a potential shock is hazard,recommend cover plates are installed as a safety precaution.• Wire ends are outside of a Junction Box, taped over at light bulb connection, recommend junctionboxes with covers be installed by licensed electrical contractor. Towards east side.• Recessed lighting in contact with insulation and no visible IC contact rating. This condition is apotential fire hazard, recommend minimum 3 inch clearance is acheived.

6. Insulation ConditionBlown in fiberglass insulation noted.Depth: Insulation averages approximately 10-12 inches in depth, estimated R value 30

Page 14: RW West Consultants, Inc....2019/05/30  · RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA Page 2 of 54 Inspection Details We appreciate the opportunity to conduct this

RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA

Page 13 of 54

7. Rodent/PestsObservations:• Bait traps present.• Droppings present.• Indications of Rodent activity. Some rodent droppings can carry disease, recommend conditionsare investigated further by licensed Pest Control Company.

Page 15: RW West Consultants, Inc....2019/05/30  · RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA Page 2 of 54 Inspection Details We appreciate the opportunity to conduct this

RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA

Page 14 of 54

General Interior Note 1. General NotesMaterials: Windows in the home are Double pane insulated glass windows. Any deficiencies arenoted in each room section for accessible windows • Accessible Doors in the home are consideredoperational unless otherwise noted in each room section • Accessible Cabinet doors and in thehome are considered operational unless otherwise noted in each room section

Page 16: RW West Consultants, Inc....2019/05/30  · RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA Page 2 of 54 Inspection Details We appreciate the opportunity to conduct this

RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA

Page 15 of 54

Entryway 1. ConditionsCeiling and walls are in good condition overall. Light fixture operates. Entry door operates andlocks overall. • Wood flooring is in good condition overall.

Page 17: RW West Consultants, Inc....2019/05/30  · RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA Page 2 of 54 Inspection Details We appreciate the opportunity to conduct this

RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA

Page 16 of 54

Living Room 1. Living RoomWalls and ceilings appear in good condition overall. Flooring is carpet. Heat register present.Accessible outlets operate.

2. FireplaceFireplace is a gas unit. • Damper is in place.Observations:• Pilot Controls are located inside access panel under glass.• Gas shutoff is located at the wall behind fireplace.• Blacken at fireplace gas can be an indication of improper air fuel mixture. recommend fireplace beserviced by licensed HVAC contractor.• Fireplace did not operate, recommend conditions are investigated further by licensed HVACcontractor.

Pilot Controls are located inside access panelunder glass.

Page 18: RW West Consultants, Inc....2019/05/30  · RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA Page 2 of 54 Inspection Details We appreciate the opportunity to conduct this

RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA

Page 17 of 54

Page 19: RW West Consultants, Inc....2019/05/30  · RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA Page 2 of 54 Inspection Details We appreciate the opportunity to conduct this

RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA

Page 18 of 54

Dining Room 1. Dining RoomWalls and ceilings appear in good condition overall. Flooring is wood. Heat register present.Accessible outlets operate.

Page 20: RW West Consultants, Inc....2019/05/30  · RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA Page 2 of 54 Inspection Details We appreciate the opportunity to conduct this

RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA

Page 19 of 54

Kitchen 1. Kitchen RoomWalls and ceilings appear in good condition overall. Flooring is wood. Accessible outlets operate.Light fixture operates. Sink and faucets are in operable condition overall. Cabinet doors anddrawers are in operable condition overall.

2. Counter ConditionStile Stone counter tops are in good condition.

3. DisposalDisposal operates overall.

4. DishwasherDishwasher was in operable condition.

5. MicrowaveObservations:• Built-in microwave ovens are tested using normal operating controls. Unit was tested andappeared to be serviceable at time of inspection. Leak and/or efficiency testing is beyond the scopeof this inspection. If concerned, client should seek further review by qualified technician prior toclosing.

6. FloorObservations:• Floor squeaks

7. Stove/OvenStove/oven were in operable condition overall.

Page 21: RW West Consultants, Inc....2019/05/30  · RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA Page 2 of 54 Inspection Details We appreciate the opportunity to conduct this

RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA

Page 20 of 54

8. RefrigeratorRefrigerator was in operable condition.

9. SinksSink was in operable condition overall.

10. ElectricalOutlets are GFCI protected at the counters.

11. Vent ConditionVent fan appears to exhaust to the exterior.

Page 22: RW West Consultants, Inc....2019/05/30  · RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA Page 2 of 54 Inspection Details We appreciate the opportunity to conduct this

RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA

Page 21 of 54

Family Room 1. Family RoomWalls and ceilings appear in good condition overall. Flooring is carpet. Heat register present.Accessible outlets operate.

2. FireplaceFireplace is a gas unit.Observations:• Pilot Controls are located inside access panel under glass.• Gas shutoff is located at the wall adjacent to the fireplace.• Fireplace did not operate, recommend conditions are investigated further by licensed HVACcontractor.

Pilot Controls are located inside access panelunder glass.

Gas shutoff is located at the wall adjacent to the fireplace.

Page 23: RW West Consultants, Inc....2019/05/30  · RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA Page 2 of 54 Inspection Details We appreciate the opportunity to conduct this

RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA

Page 22 of 54

Hallway 1. ConditionsCeiling and walls are in good condition overall. Light fixture operates. • Wood flooring is in goodcondition overallObservations:• Ceiling cracks did not appear unusual.

Page 24: RW West Consultants, Inc....2019/05/30  · RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA Page 2 of 54 Inspection Details We appreciate the opportunity to conduct this

RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA

Page 23 of 54

Laundry 1. ConditionCeiling and walls are in good condition overall. Accessible outlets operate. • Light fixture operates.

2. ElectricalObservations:• GFCI outlets have been required for Laundry and utility sinks (since 2005)No GFCI protectionpresent,, strongly recommend GFCI outlets are installed as a safety precaution.

3. Exhaust FansVent fan operates overall.

4. DryerThere is a place for dryer to exhaust to the exterior. • 220 volt electrical service for electric dryer.

Page 25: RW West Consultants, Inc....2019/05/30  · RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA Page 2 of 54 Inspection Details We appreciate the opportunity to conduct this

RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA

Page 24 of 54

5. Floor ConditionVinyl flooring appeared in good condition overall.

6. SinkSink is in operable condition overall.

7. WasherMaterials: Washer faucets were in operable condition, no visible leakage.

Page 26: RW West Consultants, Inc....2019/05/30  · RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA Page 2 of 54 Inspection Details We appreciate the opportunity to conduct this

RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA

Page 25 of 54

Master Bedroom 1. BedroomWalls and ceilings appear in good condition overall. Flooring is carpet in good condition. Heatregister present. Accessible outlets operate.

Page 27: RW West Consultants, Inc....2019/05/30  · RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA Page 2 of 54 Inspection Details We appreciate the opportunity to conduct this

RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA

Page 26 of 54

Master Bathroom 1. RoomCeiling and walls are in good condition overall. Accessible outlets operate. Light fixture operates.

2. CountersTile counter tops are in good condition overall.

3. Exhaust FansObservations:• The bath fan is a worn unit which may be at the end of its useful life.

4. FloorsTile Flooring is in good condition overall. • Carpet floor covering is in good condition.

5. TubJetted tub was in good condition overall.Observations:• Access panel not visible for tub equipment. Normally there should be an access panel for tubequipment.

Page 28: RW West Consultants, Inc....2019/05/30  · RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA Page 2 of 54 Inspection Details We appreciate the opportunity to conduct this

RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA

Page 27 of 54

6. ShowerShower is in good condition overall. • Shower door is in operable condition overall.Observations:• Shower grout absorbs moisture when water comes in contact, recommend sealing shower grout.

7. ToiletToilet was in operable condition overall.

8. HeatingHeat register operates. • Heat lamp operates.

9. ElectricalGFI for tub located inside electrical panel.

Page 29: RW West Consultants, Inc....2019/05/30  · RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA Page 2 of 54 Inspection Details We appreciate the opportunity to conduct this

RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA

Page 28 of 54

Hall Bathroom1 1. RoomCeiling and walls are in good condition overall. Accessible outlets operate. Light fixture operates.

2. ElectricalGFI outlets within 6 feet of water sources.

3. CountersTile counter tops are in good condition overall.

4. Exhaust FansVent fan operates overall.

5. FloorsWood flooring is in good condition overall

6. TubTub was in good condition overall.

7. ShowerObservations:• Shower grout absorbs moisture when water comes in contact, recommend sealing shower grout.• Shower diverter does not fully engage, recommend correction.

Page 30: RW West Consultants, Inc....2019/05/30  · RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA Page 2 of 54 Inspection Details We appreciate the opportunity to conduct this

RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA

Page 29 of 54

8. SinksSink was in operable condition overall.

9. ToiletToilet was in operable condition overall.

Page 31: RW West Consultants, Inc....2019/05/30  · RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA Page 2 of 54 Inspection Details We appreciate the opportunity to conduct this

RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA

Page 30 of 54

Bedroom 1 1. LocationLocation 1st Left

2. Bedroom RoomWalls and ceilings appear in good condition overall. Flooring is carpet. Heat register present.Accessible outlets operate.

Page 32: RW West Consultants, Inc....2019/05/30  · RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA Page 2 of 54 Inspection Details We appreciate the opportunity to conduct this

RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA

Page 31 of 54

Bedroom 2 1. Bedroom RoomWalls and ceilings appear in good condition overall. Flooring is carpet. Heat register present.Accessible outlets operate.

Page 33: RW West Consultants, Inc....2019/05/30  · RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA Page 2 of 54 Inspection Details We appreciate the opportunity to conduct this

RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA

Page 32 of 54

Garage 1. ConditionWalls and ceilings appeared in good condition overall. Accessible outlets operate. Light fixturesoperate overall. Flooring is concrete, visible portions in good condition overall.Observations:• There is no protective bollard/pole in front of gas equipment, recommend conditions are correctedto prevent automobile from accidentally hitting.• Bait traps present.

2. Floor ConditionMaterials: Flooring is concrete, appeared in good condition overall.Observations:• Cracking at the floor does not appear unusual.

3. ElectricalObservations:• Outlet and or Switch cover plates missing, recommend correction as a safety precaution.• Blackening to west outlet. Recommend conditions are investigated further and corrected bylicensed electrical contractor.

Page 34: RW West Consultants, Inc....2019/05/30  · RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA Page 2 of 54 Inspection Details We appreciate the opportunity to conduct this

RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA

Page 33 of 54

4. DoorsObservations:• Garage door leading to interior did not self close. Recommend adjustment or installing self closinghinge for fire protection and to prevent carbon monoxide from entering the living area.

5. Garage DoorsSingle garage door operates, was on auto opener. • Photo cell safety returns operate overall. •Tension safety returns operate overall.Observations:• West garage door opener unplugged. Door also sticks. Recommend further investigation bylicensed garage repair contractor.

Page 35: RW West Consultants, Inc....2019/05/30  · RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA Page 2 of 54 Inspection Details We appreciate the opportunity to conduct this

RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA

Page 34 of 54

Page 36: RW West Consultants, Inc....2019/05/30  · RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA Page 2 of 54 Inspection Details We appreciate the opportunity to conduct this

RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA

Page 35 of 54

Heat/AC 1. Heating TypeGas forced air furnace. • There was good air flow at the heat registers and cold air returns.

2. Heater Location The furnace is located in the garageFurnace is American Standard Brand • 10 years of age approximately, average life span is 18 to 22years.

3. Heating conditionObservations:• Service does not appear to have been performed within the last year, recommend serviced bylicensed HVAC contractor.• Tape on shutoff button. Recommend removal.• There was no visible disconnect/kill switch, recommend conditions are investigated further andcorrected as required by licensed HVAC contractor

Page 37: RW West Consultants, Inc....2019/05/30  · RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA Page 2 of 54 Inspection Details We appreciate the opportunity to conduct this

RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA

Page 36 of 54

Service Record

4. Venting

5. FiltersLocation: Left side of furnace filter location

Page 38: RW West Consultants, Inc....2019/05/30  · RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA Page 2 of 54 Inspection Details We appreciate the opportunity to conduct this

RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA

Page 37 of 54

Page 39: RW West Consultants, Inc....2019/05/30  · RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA Page 2 of 54 Inspection Details We appreciate the opportunity to conduct this

RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA

Page 38 of 54

Plumbing/Water Heater1 1. PlumbingWater lines were copper • Drain and waste lines were plastic.

2. Water Heater ConditionHeater Type: Gas Water heater. • 50 gallonsLocation: The heater is located in the garage.

3. AgeObservations:• Water heater in excess of 12 years and has exceeded useful life span, recommend monitoring orreplacement.• Approximately 14 years of age, average life span is 10 to 12 years.

4. ConditionSeismic straps are in place. • Expansion tank is in place.

5. TPRV ConditionTemperature Pressure Relief Valve (TPR Valve) present.

Definition
An expansion tank or expansion vessel is a small tank used to protect closed (not open to atmospheric pressure) water heating systems and domestic hot water systems from excessive pressure. The tank is partially filled with air, whose compressibility cushions shock caused by water hammer and absorbs excess water pressure caused by thermal expansion.
Definition
The thermostat in a water heater shuts off the heating source when the set temperature is reached. If the thermostat fails, the water heater could have a continuous rise in temperature and pressure (from expansion of the water). The temperature and pressure could continue to rise until the pressure exceeds the pressure capacity of the tank (300 psi). If this should happen, the super-heated water would boil and expand with explosive force, and the tank would burst. The super-heated water turns to steam and turns the water heater into an unguided missile. To prevent these catastrophic failures, water heaters are required to be protected for both excess temperature and pressure. Usually, the means of protection is a combination temperature- and pressure-relief valve (variously abbreviated as T&P, TPV, TPR, etc.). Most of these devices are set to operate at a water temperature above 200° F and/or a pressure above 150 psi. Do not attempt to test the TPR valve yourself! Most water heating systems should be serviced once a year as a part of an annual preventive maintenance inspection by a professional heating and cooling contractor. From Plumbing: Water Heater TPR Valves
Page 40: RW West Consultants, Inc....2019/05/30  · RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA Page 2 of 54 Inspection Details We appreciate the opportunity to conduct this

RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA

Page 39 of 54

6. Venting

Page 41: RW West Consultants, Inc....2019/05/30  · RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA Page 2 of 54 Inspection Details We appreciate the opportunity to conduct this

RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA

Page 40 of 54

Electrical 1 1. LocationMaterials: Located in the Garage

2. Electrical200 AMP service, 4/0 Aluminum service entrance wires.

3. GroundingElectrical service is bonded.Observations:• Grounding is not visible/cannot be traced to source and cannot be verified. Strongly recommendconditions investigated further are corrected by licensed electrical contractor.

4. Wiring TypeBreaker system present. Wiring sizes conform to breaker sizes overall. Smaller branch circuit wiringis copper.

Page 42: RW West Consultants, Inc....2019/05/30  · RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA Page 2 of 54 Inspection Details We appreciate the opportunity to conduct this

RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA

Page 41 of 54

Foundation/Crawlspaces 1 1. FoundationContinuous concrete foundation visible portion appeared in good condition overall.

2. DrainageCrawlspace was dry overall.

3. FramingVisible framing appeared in good condition overall.Observations:• Cardboard and or wood forms still attached to concrete piers/forms, typically this material shouldbe removed as it is a conducive condition for wood destroying organism activity.

4. VentilationVentilation appeared adequate.

Page 43: RW West Consultants, Inc....2019/05/30  · RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA Page 2 of 54 Inspection Details We appreciate the opportunity to conduct this

RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA

Page 42 of 54

5. DuctsDucts appeared securely attached and insulated overall.

6. Vapor BarrierVapor barrier was mostly in place.Observations:• Missing incomplete/vapor barrier, recommend 6 mil black plastic vapor barrier is installed withminimum 12 inch lap. This is a conducive condition for wood decay and mold growth• Clear plastic vapor barrier, newer requirements are 6 mil black plastic vapor barrier.

Page 44: RW West Consultants, Inc....2019/05/30  · RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA Page 2 of 54 Inspection Details We appreciate the opportunity to conduct this

RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA

Page 43 of 54

7. PlumbingObservations:• Water lines are not insulated or completely insulated, recommend insulating water lines to preventfreezing. Water line entering from street.

8. Insulation ConditionUnfinished fiberglass batts noted.Depth: Insulation averages approximately 6 inches in depth;estimated R value 19. Newerrequirements are R30 insulation content.Observations:• Insulation damaged/missing in areas of the crawlspace, recommend conditions are corrected.

Page 45: RW West Consultants, Inc....2019/05/30  · RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA Page 2 of 54 Inspection Details We appreciate the opportunity to conduct this

RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA

Page 44 of 54

9. Rodent/PestsObservations:• Indications of Rodent activity. Some rodent droppings can carry disease. rodents can also causedamage to insulation. Recommend conditions are investigated further by licensed Pest ControlCompany.• Droppings present.• Carcasses present.• Urine Present

Page 46: RW West Consultants, Inc....2019/05/30  · RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA Page 2 of 54 Inspection Details We appreciate the opportunity to conduct this

RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA

Page 45 of 54

Page 47: RW West Consultants, Inc....2019/05/30  · RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA Page 2 of 54 Inspection Details We appreciate the opportunity to conduct this

RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA

Page 46 of 54

Shutoffs 1. Shutoff Locations

Furnace gas shutoff is located to the left of thefurnace.

Water Heater gas shutoff is located to the right ofthe water heater.

Water heater water line shutoff is located abovethe water heater.

Main water shutoff is located on the east wall ofthe garage.

Page 48: RW West Consultants, Inc....2019/05/30  · RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA Page 2 of 54 Inspection Details We appreciate the opportunity to conduct this

RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA

Page 47 of 54

Pressure regulator located left of water shutoff.

Page 49: RW West Consultants, Inc....2019/05/30  · RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA Page 2 of 54 Inspection Details We appreciate the opportunity to conduct this

RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA

Page 48 of 54

Equipment 1. Appliances/EquipmentObservations:• Oven• Refrigerator• Dishwasher• Microwave• Disposal• Water Heater• Furnace• Alarm control panel, testing of this system is not within the scope of this inspection.

Water heater Furnace

Alarm Microwave

Page 50: RW West Consultants, Inc....2019/05/30  · RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA Page 2 of 54 Inspection Details We appreciate the opportunity to conduct this

RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA

Page 49 of 54

Oven Refrigerator

Dishwasher

Page 51: RW West Consultants, Inc....2019/05/30  · RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA Page 2 of 54 Inspection Details We appreciate the opportunity to conduct this

RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA

Page 50 of 54

Carbon Monoxide Detectors 1. Carbon MonoxideObservations:• As of April 1st 2012 it is required that Carbon monoxide detectors are installed on each level andoutside of bedroom areas. Recommend conditions are corrected.

Page 52: RW West Consultants, Inc....2019/05/30  · RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA Page 2 of 54 Inspection Details We appreciate the opportunity to conduct this

RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA

Page 51 of 54

GlossaryGlossary

Term Definition

Expansion Tank An expansion tank or expansion vessel is a small tank used toprotect closed (not open to atmospheric pressure) water heatingsystems and domestic hot water systems from excessivepressure. The tank is partially filled with air, whosecompressibility cushions shock caused by water hammer andabsorbs excess water pressure caused by thermal expansion.

GFCI A special device that is intended for the protection of personnelby de-energizing a circuit, capable of opening the circuit wheneven a small amount of current is flowing through the groundingsystem.

TPR Valve The thermostat in a water heater shuts off the heating sourcewhen the set temperature is reached. If the thermostat fails, thewater heater could have a continuous rise in temperature andpressure (from expansion of the water). The temperature andpressure could continue to rise until the pressure exceeds thepressure capacity of the tank (300 psi). If this should happen, thesuper-heated water would boil and expand with explosive force,and the tank would burst. The super-heated water turns to steamand turns the water heater into an unguided missile. To preventthese catastrophic failures, water heaters are required to beprotected for both excess temperature and pressure. Usually, themeans of protection is a combination temperature- and pressure-relief valve (variously abbreviated as T&P, TPV, TPR, etc.). Mostof these devices are set to operate at a water temperature above200° F and/or a pressure above 150 psi. Do not attempt to testthe TPR valve yourself! Most water heating systems should beserviced once a year as a part of an annual preventivemaintenance inspection by a professional heating and coolingcontractor. From Plumbing: Water Heater TPR Valves

Page 53: RW West Consultants, Inc....2019/05/30  · RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA Page 2 of 54 Inspection Details We appreciate the opportunity to conduct this

RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA

Page 52 of 54

Report SummaryReport Summary

This is a visual inspection. No destructive testing is performed.  This is not a soil inspection nor dowe inspect for formaldehyde, radon, asbestos, Chinese drywall, lead paint, mold, hazardousmaterials/substances, landscape lighting, sprinkler systems, septic systems/drain fields, smokealarms or recreational equipment such as Jacuzzis etc.. It is recommended that noted deficienciesbe investigated further by licensed companies specializing in those disciplines. Inspection is subjectto conditions at the time of inspection. Appliances are checked to see if they're in operable condition.This is not a code inspection as codes change frequently and vary between municipalities. We makeno guarantees for expected life. It is impossible to verify conditions of places inaccessible in wallsunder and in between floors, behind furniture appliances etc., and we assume no responsibility forthose items as such. Estimates for repairs are approximations and we do not guarantee theiraccuracy. Possible solutions for problems are solely opinions based on conditions at the time of theinspection and are not to be assumed as being totally conclusiveThe summary below consists of potentially significant findings. These findings can be a safetyhazard, a deficiency requiring a major expenses or further investigation to correct or items I wouldlike to draw extra attention to. The summary is not a complete listing of all the findings in the report,and reflects the opinion of the inspector. Please review all of the pages of the report as the summaryalone does not explain all the issues. We recommend repairs should be done by licensed &bondedcontractors. We also recommend obtaining a copy of all receipts, warranties and permits for the workdone. Exterior AreasPage 5 Item: 7 Electrical • GFCI outlets have been required at exterior (since 1973) No

GFCI protection present at north side. strongly recommendGFCI outlets are installed as a safety precaution.

Attic 1Page 10 Item: 2 Framing • Slight darkened coloration that possibly could be a

fungal/mold growth in a number or areas. Conditions aregenerally a result of excessive moisture at some point orinadequate ventilation. Treating/remediation and correctionmoisture conditions will help prevent future occurrences.Testing would need to be performed to determine thepresence or absence of Mold. Testing may include surfacesampling and air quality testing.

Page 11 Item: 4 Fan/Duct • Not All Bathroom fans exhaust completely to the exterior.Typically piping should actually connect to exterior vent,recommend correction. This condition can result inmold/fungal growth.

Page 12 Item: 5 Electrical • Electrical switch/Junction Box Covers missing or damaged,which is a potential shock is hazard, recommend cover platesare installed as a safety precaution.• Wire ends are outside of a Junction Box, taped over at lightbulb connection, recommend junction boxes with covers beinstalled by licensed electrical contractor. Towards east side.• Recessed lighting in contact with insulation and no visible ICcontact rating. This condition is a potential fire hazard,recommend minimum 3 inch clearance is acheived.

Page 13 Item: 7 Rodent/Pests • Bait traps present.• Droppings present.• Indications of Rodent activity. Some rodent droppings cancarry disease, recommend conditions are investigated furtherby licensed Pest Control Company.

Definition
A special device that is intended for the protection of personnel by de-energizing a circuit, capable of opening the circuit when even a small amount of current is flowing through the grounding system.
Page 54: RW West Consultants, Inc....2019/05/30  · RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA Page 2 of 54 Inspection Details We appreciate the opportunity to conduct this

RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA

Page 53 of 54

Living RoomPage 16 Item: 2 Fireplace • Blacken at fireplace gas can be an indication of improper air

fuel mixture. recommend fireplace be serviced by licensedHVAC contractor.• Fireplace did not operate, recommend conditions areinvestigated further by licensed HVAC contractor.

Family RoomPage 21 Item: 2 Fireplace • Fireplace did not operate, recommend conditions are

investigated further by licensed HVAC contractor.LaundryPage 23 Item: 2 Electrical • GFCI outlets have been required for Laundry and utility sinks

(since 2005)No GFCI protection present,, stronglyrecommend GFCI outlets are installed as a safety precaution.

GaragePage 32 Item: 1 Condition • There is no protective bollard/pole in front of gas equipment,

recommend conditions are corrected to prevent automobilefrom accidentally hitting.• Bait traps present.

Page 33 Item: 3 Electrical • Outlet and or Switch cover plates missing, recommendcorrection as a safety precaution.• Blackening to west outlet. Recommend conditions areinvestigated further and corrected by licensed electricalcontractor.

Page 33 Item: 4 Doors • Garage door leading to interior did not self close.Recommend adjustment or installing self closing hinge for fireprotection and to prevent carbon monoxide from entering theliving area.

Heat/ACPage 35 Item: 3 Heating condition • There was no visible disconnect/kill switch, recommend

conditions are investigated further and corrected as requiredby licensed HVAC contractor

Plumbing/Water Heater1Page 38 Item: 3 Age • Water heater in excess of 12 years and has exceeded useful

life span, recommend monitoring or replacement.• Approximately 14 years of age, average life span is 10 to 12years.

Electrical 1Page 40 Item: 3 Grounding • Grounding is not visible/cannot be traced to source and

cannot be verified. Strongly recommend conditionsinvestigated further are corrected by licensed electricalcontractor.

Foundation/Crawlspaces 1Page 44 Item: 9 Rodent/Pests • Indications of Rodent activity. Some rodent droppings can

carry disease. rodents can also cause damage to insulation.Recommend conditions are investigated further by licensedPest Control Company.• Droppings present.• Carcasses present.• Urine Present

Carbon Monoxide Detectors

Page 55: RW West Consultants, Inc....2019/05/30  · RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA Page 2 of 54 Inspection Details We appreciate the opportunity to conduct this

RW West Consultants, Inc. 11735 SE 78th Pl, Newcastle, WA

Page 54 of 54

Page 50 Item: 1 Carbon Monoxide • As of April 1st 2012 it is required that Carbon monoxidedetectors are installed on each level and outside of bedroomareas. Recommend conditions are corrected.