Powering schemes

Post on 12-Jan-2016

71 views 0 download

description

Serial Powering of Silicon Strip Detectors at SLHC Marc Weber, Giulio Villani, M. Tyndel (RAL) with Anu Tuonnonnen and Robert Apsimon. Could this scheme be better?. Independent powering. PS. PS. PS. PS. PS. PS. PS. PS. PS. Power in Power out. PS. PS. Powering schemes. - PowerPoint PPT Presentation

Transcript of Powering schemes

1

Serial Powering of Silicon Strip Detectors at SLHC

Marc Weber, Giulio Villani, M. Tyndel (RAL)with Anu Tuonnonnen and Robert Apsimon

2

Powering schemesIndependent powering

PS PS PS PSPS

PS PSPS

PSPS

Could this scheme be better?

Power in Power out

PS

3

How to power a SLHC tracker ?Many unknowns, but power will be a major challenge and affects cooling, material budget, packaging and more

Focus of this talk is on silicon strip sensors. There is earlier powering stuff for ATLAS pixels by Bonn university group

KnownSCT: up to 160 m long cables, cable resistance up to ~ 3.5 ΩSCT: power efficiency 50%, 25 kW module power; 50 kW total

Estimate (assuming lower voltages, similar current and cable resistance)

SLHC: power efficiency 20%, if 50 kW modules power 400 kW total

This is a power station not a tracker !

4

Why independent powering fails at SLHC ?

1. Don’t get 5 or 10 times more cables in

2. Power efficiency is too low (50% SCT 20% SLHC)

3. Material budget: 0.2% or R.L. per layer (barrel normal incidence) 1% or 2% SLHC

4. Packaging constraints

Each reason by itself is

probably sufficient for a

No-No

5

Serial powering and parallel power bus with DC-DC conversion

Note: Parallel powering without DC-DC conversion is problematic due to low power efficiency and large IR drops

Alternatives to IP

M1 M2 M3

M1 M2 M3

M1 M2 M3

IP

PP with DC-DC conversion

SP

Analog and digital voltage

Constant current for both analog and

digital power

6

Four elements

Current source

Shunt regulator and power device (digital power)

Linear regulator (analog power)

AC or opto-coupling of signals

How does SP work?

7

Regulators

8V

4V

4V

0V

Chain of modules at different voltages

Chips on a module are connected in parallel (as usual)

analog ground, digital ground and HV ground are tight together for each module (as usual) floating HV supplies

8

AC LVDS coupling

All but one module are on different potential than DAQ

LVDS buffers are at the potential of the receiving unit (DAQ power for data; module power for

clock/control)

Opto-decoupling is an alternative

Simplified AC coupling diagram

9

Power efficiency ratio (SP/IP) Vs # of modules

1

1.5

2

2.5

3

3.5

4

4.5

5

1 6 11 16 21 26

# of modules (n)

(1+

x)/(

1+x/

n)

x = 4.5 (SLHC)

x = 1.14 (LHC)

Reduce number of cables by factor 2x2n/2=2n (even more if counting sense wires)

Huge increase of power

efficiency over IP as Vdd goes

down: [1+x]/[1 + x/n]

x = cable IR/Vdd

material reduction

cost savings (cables and PS)

Same benefits for DC-DC conversion

Advantages of serial powering

M1 M2 M3 M1 M2 M3

~1+x

SLHC

Vdd=1V

“SCT”

Vdd=4V

Combining analog and digital cables

10

“ Only a physicist can be crazy enough to try this!”

Noisy; oscillations; interference between modules

probably not main difficulty

Risky; can lose all modules due to single-point failure

Much less risky than one might think

Loss of control over individual modules

important constraint that can be addressed to some extent

Grounding and shielding of densely packaged extended system

is part of stave R&D

Perceived disadvantages of SP

11

Serial powering of six ATLAS SCT modules

12

Serial powering interface board with regulator and AC coupling

Commercial components; connectors

SCT modules are untouched; standard SCT PS is not used

13

Schematic of Shunt regulator

Simple but effective design

Will be integrated in custom RDIC or dedicated ASIC in the future

(ATLAS pixel chip contains active circuitry already)

14

SP interface board in more detail

Shunt regulator and power transistor; analog regulator 3 x AC LVDS coupling (clock/control/data)

LVDS buffer circuitries

Shunt regulator circuitry Linear regulator circuitry

D

A

Q

M

O

D

U

L

E

Large area prototype for small board (see Carl’s talk)

15

We can make this much smaller 2+2 layer PCB; 38 x 9 mm2 (this is a PCB for cost reasons)

Further shrinkage if SP integrated into hybrid and if most circuits elements integrated into readout ICs

Estimated extra hybrid floor area due to SP: ~10%

Hybrid

SSPPCB

ABCD3TV2

16

Hybrid noise with and without SP boardDistribution of ENC for IP and SP for hybrid 19

0

10

20

30

40

50

60

70

80

90

500 550 600 650 700 750 800

ENC

# o

f ch

ann

els

IP

SP

This is “serial powering” of one hybrid (4-chip LBNL hybrid)

Bare hybrid measurements are most sensitive

SP noise performance is excellent regulators work fine

LBNL IPRAL SP

17

Noise performance of 6 SCT modules

<ENC> Vs module number for IP and SP with 6 modules

1420

1440

1460

1480

1500

1520

1540

1560

1580

1600

755 663 159 628 662 006

Module #

<E

NC

> IP

SP

Precise measurements; noise performance of SP is excellent

18

A closer look at the same data

ENC against channel number for IP and SP for module 663

0

500

1000

1500

2000

2500

0 200 400 600 800 1000 1200 1400

Channel #

EN

C IP

SP

Gain against channel number for IP and SP for module 663

0

10

20

30

40

50

60

70

0 200 400 600 800 1000 1200 1400

Channel #

Gai

n IP

SP

Combining two data streams (link0 and link1) saves space don’t read out chip 7

SP and IP noise and gain are very similar

The same is true for the other 5 modules (not shown)

Channel Channel

ENC Gain

19

Noise distribution of one of the 6 SCT modules

Distribution of ENC for IP and SP for module 662

0

20

40

60

80

100

120

140

1000 1100 1200 1300 1400 1500 1600 1700 1800

ENC

# o

f ch

ann

els

IP

SP

Noise performance of SP is excellent

20

Noise injectionPrinciple: superimpose a current modulation of 15 mA to 1.6 A current;

scan through a frequency range from Hz to 40 MHz;

measure module noise

21

Noise injection: SP with 6 SCT modulesENC against frequency of injected noise

1350

1400

1450

1500

1550

1600

1650

1 100 10000 1000000 100000000

Frequency (Hz)

EN

C

Module 662

Module 006

Module 159

Module 663

Module 755

Module 628

No significant increase in noise

Note that coupling of noise between modules through power line is not possible conservation of charge/current!

Frequency [Hz]

<ENC>

22

Is serial powering to risky?

Risk of module loss due to single-point failures for IP and SP

Over current protection through shunt regulator design

Protection by operating SR in parallel

Risk = (# of power connections) x (probability of a failure) x (# of modules lost per failure)

I am sure there are other ways to define risk, but this is instructive

23

Risk comparison: IP vs SPDistribution Board

Module 1

Module 2

Module n

Digital PS 1

Digital PS 2

Digital PS n

Analog PS 1

Analog PS 2

Analog PS n

Independent Powering

Wirebonds

CablesType 1

CablesType 2

Connections (analog + digital)

4n + 4n

4n + 4n

4n + 4n

Probability of a failure

aIP bIP cIP

Lost modules 1 1 1

Distribution Board

Module 1 Module 2

Power supply

Module n

SP: one broken connection loses n modules

however, much less cables less connections

Serial Powering

Wirebonds

CablesType 1

CablesType 2

connections (analog + digital)

2 (n+1)

4 4

Probability of a failure

aSP bSP cSP

Lost modules

n n n

IP

SP

24

Risk comparison Risk ratio against number of modules in SP chain

0

1

2

3

4

5

6

7

8

9

10

0 5 10 15 20 25 30 35

# of modules

Ris

k ra

tio

(S

P/I

P)

Case 1

Case 2

Case 3

Case 4

Risk due to breaking bonds/connections is larger for SP, but less than one might think

Risk increases ~ number of modules/4 Build in increased redundancy

Risk ratio (SP/IP)

IPIPIP

SPSPSP

cba

cbna

4

221

# of modules

Make your own choices for values of

a,b, and c

Mine are here …

25

Architecture choices: single vs. multi- SR arrangement

Single SR and LR for 2 chips 2 parallel SR and LR for 2 chips

Remember, in SP you have to fight opens! (in PP, shorts)

Parallel SR and LR arrangement is safer (SR and LR are part of RDIC)

Failure of one power transistor does not kill all modules

Can also use register to set voltages on chip

RDIC RDICRDIC RDIC

26

Overcurrent protectionPower transistor is weakest point of SR regulator

It has to stand full current in case of a module open risk of burn out

Protect against this by automatically reducing SR voltage in case of overcurrent condition

Simplified diagram for illustration of overcurrent protection

27

AC LVDS couplingWe use two different schematics

Command/data signal: feed-back resistor between input and output of LVDS buffer (value should be high enough to allow for multi-drop configurations)

Clock: LVDS buffer input is pulled to buffer ground ( non-standard common mode level)

Clock

Command

28

AC LVDS couplingTested AC LVDS coupling with dedicated test circuits for large range of duty cycles and frequencies ; this is work in progress

This works just fine in practice; conventional wisdom is that you should not do it this way

(no DC balanced protocol; no 0V common-mode)

We will find out why it works…

120 MHz

1 MHz

1 MHz 40 MHz

29

Future R&D program on powering schemes

Goal: be ready for implementation of advanced SP and DC-DC conversion PP systems in a realistic module assembly in ~ 3 years

Can distinguish three phases:

Generic studies (as presented here and in Carl’s talk) to identify crucial features and challenges “easy”, affordable, “fun”

Develop radiation-hard custom electronics (ABC_Next chip); build and test systems with large number of modules significant effort, serious engineering

Implemention of power distribution schemes on advanced supermodule prototypes “service”, crucial to establish supermodule electrical performance

30

What we have learnt so far Noise performance is excellent; expect SP systems to be less noisy than alternatives; IR drops don’t matter for one

Risk of failure is bigger than for IP but much smaller than naively expected; SP/IP risk ~ n/4; can use fraction of space gains to buy robustness; protect power transistor

Power efficiency is hugely improved (depending on x=IR/V); 20% (IP) -> 80% (SP) can save >100 kW of cable losses easily; power consumption of SP circuitry is small, dominated by excess current in power transistor

Need to emphasize voltage adjustment and feed-back from individual modules (slow control)

31

Outlook

It unusual to gain such significant factors in a technology as mature as silicon detectors

SP is challenging but I believe we can make it work

If you are sceptical about these concepts, remember that we need to innovate. Without new powering schemes, we will

simply not get any SLHC tracking detectors

Last, but not least:

this not only of interest for SLHC. ILC tracker or non-silicon detectors might benefit as well

32

Appendix

33

Same board used with bare hybrid

HybridS P P C B

DAQ support card

34

A closer look using a single hybrid<ENC> against frequency of injected noise for hybrid 24

614

615

616

617

618

619

620

621

1 10 100 1000 10000 100000 1000000 10000000 1E+08

Frequency (Hz)

<E

NC

>

35

No more cables please

36

First simulation results

Vout

Iin

Comp Vcout

Comparator Vin+

Comparator Vin-

37

38

A look at material issues

naively extrapolating from an SCT to an SLHC layer assuming 5 times more channels, we get (one layer, barrel, normal impact):

Material budget will explode at SLHC without innovations in powering, packaging, and cooling

Component R.L. for SCT

Scaling factor*

R.L. for

SLHC

Cable 0.2 % x 5 1 %

Hybrid 0.3 % x 5 1.5 %

Sensor 0.6 % x 1 0.6 %

Cooling; CF cylinders; module baseboard; etc.

0.4; 0.3;

0.2 %

x 3; x 1; x 1

1.7 %

Total 2 % 5 %

Silicon fraction 30 % 12 %

too big !

*crude estimate; no innovation

39

A look at material issues

services in ATLAS SLHC tracker would still run in gap between barrel and end cap detectors

in current SCT, particles cross (0.1 to 0.45%) x √2 of R.L. of cables in gap alone (dep. on polar angle)

a 5 or 10-fold increase of these numbers is prohibitive

DiscsBarrelInteraction point

Cables Generic ATLAS SLHC

Tracker Configuration

40

Let’s look at 4 different powering set-ups for a stave with n modules

1. Each module is independently powered (IP scheme)

2. Power busses on stave serve modules in parallel (PP)

3. Parallel, but with DC-DC conversion (DCP) …

4. Modules are chained in series (SP)

Definitions: Module current and voltage: I, V Cable resistance (including return): R

power consumed by stave with n modules is always: n I V power wasted in the cable varies with powering scheme

Power efficiency

M1 M2 M3

M1 M2 M3

M1 M2 M3

41

Power efficiency

Ignoring effects of regulators and other complications, get easy dependencies

Efficiency decreases with increasing R, I and decreasing V

Significant advantage for serial powering and DC-DC, even for small numbers of modules n and small gain g

Istave Vdrop Vstave Pcable PstaveEfficiency: Pstave/Ptotal

IP n I I R V n I2R n I V 1/[1 + IR/V]

PP n I n I R V n2 I2R n I V 1/[1 + nIR/V]

SP I I R nV I2R n I V 1/[1 + IR/nV]

DCP (n/g) I

(n/g) I R

gV (n/g)2

I2R

n I V 1/[1 + nIR/g2V]