Vela User™s Guide...NPPV SIMV NPPV AP PSV NPPV A/C olume A/C MODE SELECT APNEA MODE lume Setting...

40
Vela Users Guide

Transcript of Vela User™s Guide...NPPV SIMV NPPV AP PSV NPPV A/C olume A/C MODE SELECT APNEA MODE lume Setting...

Page 1: Vela User™s Guide...NPPV SIMV NPPV AP PSV NPPV A/C olume A/C MODE SELECT APNEA MODE lume Setting the Ventilation Breath Type and Mode 1. Touch the Mode Indicator to open the mode

Vela User�s Guide

Page 2: Vela User™s Guide...NPPV SIMV NPPV AP PSV NPPV A/C olume A/C MODE SELECT APNEA MODE lume Setting the Ventilation Breath Type and Mode 1. Touch the Mode Indicator to open the mode
Page 3: Vela User™s Guide...NPPV SIMV NPPV AP PSV NPPV A/C olume A/C MODE SELECT APNEA MODE lume Setting the Ventilation Breath Type and Mode 1. Touch the Mode Indicator to open the mode

Table of Contents

Vela Ventilator� Front Panel ................................................................................................................................1

Vela Ventilator� Rear Panel ................................................................................................................................3

Circuit Assembly....................................................................................................................................................5

Touch-Turn-Touch�/Touch-Turn-Accept�............................................................................................................9

Extended Function Testing ................................................................................................................................11

Fi02 Monitor Calibration ....................................................................................................................................13

New Patient Set-up ............................................................................................................................................15

Setting the Ventilation Breath Type and Mode ................................................................................................17

Monitored Parameters ......................................................................................................................................19

Graphics ..............................................................................................................................................................23

Synchronized Nebulizer......................................................................................................................................29

Oxygen Computer Chart ....................................................................................................................................31

Contact Information............................................................................................................................................33

Notes ..................................................................................................................................................................34

The Vela User�s Guide is not intended as a replacement for the Operator�s Manual. You must become completely familiar with the Vela Operator�s Manual before using the Vela ventilator.

Page 4: Vela User™s Guide...NPPV SIMV NPPV AP PSV NPPV A/C olume A/C MODE SELECT APNEA MODE lume Setting the Ventilation Breath Type and Mode 1. Touch the Mode Indicator to open the mode

This page intentionally left blank.

Page 5: Vela User™s Guide...NPPV SIMV NPPV AP PSV NPPV A/C olume A/C MODE SELECT APNEA MODE lume Setting the Ventilation Breath Type and Mode 1. Touch the Mode Indicator to open the mode

ACDC

DCSTATUS

CANCEL

ACCEPT

PANELLOCK

NEBULIZER 100%O2

MANUALBREATH

EXPHOLD

FREEZE INSPHOLD

ALARMSILENCE

ALARMRESET

P R E S S U R E A / C MAIN

ADVSETTINGS LIMITS SETUP

mLVti

mLVte

cmH2OPpeak

cmH2OPEEP

%FiO2

Man Brth Silence

5

PEEPcmH2O

5

Flow trigLPM

21

%O2%

22

Insp PresscmH2O

1.0

Insp TimeSec

20

RateBPM

39138028521

Lk Comp Vol Min

40

20

-208040

-40

0

0

-80

750500250

0-250

Paw (cmH O)2

V (lpm).

V (ml)

2 4 6 8 10 12

2 4 6 8 10 12

2 4 6 8 10 12

t

FROM PATIENT

TOPATIENT

PRESSURERELIEF

MONITORED PARAMETERS

MODEINDICATOR

SCREENINDICATOR

ALARM STATUSINDICATOR

DATA DIAL

PRIMARYCONTROLS

MESSAGEWINDOW

EFFORTINDICATOR

POWERINDICATORS

NEBULIZEROUTPUT

EXPIRATORYFLOW SENSOR

PRINT

1 Vela User�s Guide L1536 Rev. C

Vela Ventilator Front Panel

Vela Front Panel

Page 6: Vela User™s Guide...NPPV SIMV NPPV AP PSV NPPV A/C olume A/C MODE SELECT APNEA MODE lume Setting the Ventilation Breath Type and Mode 1. Touch the Mode Indicator to open the mode

2 Vela User�s Guide L1536 Rev. C

This page intentionally left blank.

Page 7: Vela User™s Guide...NPPV SIMV NPPV AP PSV NPPV A/C olume A/C MODE SELECT APNEA MODE lume Setting the Ventilation Breath Type and Mode 1. Touch the Mode Indicator to open the mode

3 Vela User�s Guide L1536 Rev. C

Vela Ventilator Rear Panel

A - Power Switch

B - Fan and Fan Filter

C - Printer Port

D - VGA Port

E - Non-Operational Port

F - High Pressure Oxygen Fitting

G - Low Pressure Oxygen Fitting

H - Nurse Call System Connection

I - Alarm Speaker

J - Power Cord

K - Fuses

L - Ground

M - Alarm Volume Adjustment

N - Fiber Optic Output Port

A

B

C

D

E

F

G

H

I

J

K

L

MN

Vela Rear Panel

Page 8: Vela User™s Guide...NPPV SIMV NPPV AP PSV NPPV A/C olume A/C MODE SELECT APNEA MODE lume Setting the Ventilation Breath Type and Mode 1. Touch the Mode Indicator to open the mode

4 Vela User�s Guide L1536 Rev. C

This page intentionally left blank.

Page 9: Vela User™s Guide...NPPV SIMV NPPV AP PSV NPPV A/C olume A/C MODE SELECT APNEA MODE lume Setting the Ventilation Breath Type and Mode 1. Touch the Mode Indicator to open the mode

5 Vela User�s Guide L1536 Rev. C

Circuit Assembly

1. Install the diaphragm on the exhalation valve.Carefully seat the rim of the diaphragm on theexhalation valve and gently press around the rimto ensure it is seated evenly as shown.

2. Line up the fins on the exhalation valve bodywith the exhalation valve housing.

Circuit Assembly

Page 10: Vela User™s Guide...NPPV SIMV NPPV AP PSV NPPV A/C olume A/C MODE SELECT APNEA MODE lume Setting the Ventilation Breath Type and Mode 1. Touch the Mode Indicator to open the mode

6 Vela User�s Guide L1536 Rev. C

Circuit Assembly

3. Rotate clockwise until it clicks into place. 4. Attach the flow sensor with the flow tubes in anupright position.

Page 11: Vela User™s Guide...NPPV SIMV NPPV AP PSV NPPV A/C olume A/C MODE SELECT APNEA MODE lume Setting the Ventilation Breath Type and Mode 1. Touch the Mode Indicator to open the mode

7 Vela User�s Guide L1536 Rev. C

Circuit Assembly

5. To connect the smart connector for the variable orifice flow sensor, pull back the lockingsleeve. Push into the receptacle and slide thelocking sleeve forward to secure. To remove,repeat these steps in reverse order.

Page 12: Vela User™s Guide...NPPV SIMV NPPV AP PSV NPPV A/C olume A/C MODE SELECT APNEA MODE lume Setting the Ventilation Breath Type and Mode 1. Touch the Mode Indicator to open the mode

8 Vela User�s Guide L1536 Rev. C

FROM PATIENT

NEBULIZEROUTPUT

EXPIRATORY LIMB OF PATIENT CIRCUIT

INSPIRATORY LIMB OF PATIENT CIRCUIT

TOPATIENT PRESSURE

RELIEF

EXPIRATORYFLOW SENSOR

Circuit Assembly

Complete Patient Circuit Assembly

Page 13: Vela User™s Guide...NPPV SIMV NPPV AP PSV NPPV A/C olume A/C MODE SELECT APNEA MODE lume Setting the Ventilation Breath Type and Mode 1. Touch the Mode Indicator to open the mode

9 Vela User�s Guide L1536 Rev. C

Touch-Turn-Touch� / Touch-Turn-Accept�

Changes to controls and displays are accomplished with a three-step technique.

1. Touch the control or display to be changed. 2. Turn the data dial to reach the desired setting.

3. Touch the control again OR press "ACCEPT" toconfirm the change.

Changes not accepted by either method within 15 seconds revertto previous settings. Press "CANCEL" prior to accepting proposedchanges to return to previous settings.

BPMRate

15ml

Volume

500

Touch-Turn-Touch� /Touch-Turn-Accept�

Page 14: Vela User™s Guide...NPPV SIMV NPPV AP PSV NPPV A/C olume A/C MODE SELECT APNEA MODE lume Setting the Ventilation Breath Type and Mode 1. Touch the Mode Indicator to open the mode

10 Vela User�s Guide L1536 Rev. C

This page intentionally left blank.

Page 15: Vela User™s Guide...NPPV SIMV NPPV AP PSV NPPV A/C olume A/C MODE SELECT APNEA MODE lume Setting the Ventilation Breath Type and Mode 1. Touch the Mode Indicator to open the mode

11 Vela User�s Guide L1536 Rev. C

Extended Functions Testing

The extended functions menu allows access to stored data, performance calibrations and customization of the frontpanel. Touch the screen indicator to access the extended functions menu. When the screen select menu appears,press the Extended Functions button.

Extended Functions Menu

Extended Functions Testing

Page 16: Vela User™s Guide...NPPV SIMV NPPV AP PSV NPPV A/C olume A/C MODE SELECT APNEA MODE lume Setting the Ventilation Breath Type and Mode 1. Touch the Mode Indicator to open the mode

12 Vela User�s Guide L1536 Rev. C

Extended Functions Testing

Events Stores data events for Service evaluation & troubleshooting. *

Transducer Data Allows setting of transducer analog outputs for Service. *

Transducer Test Allows Service testing of transducer function. *

Version Info Displays software version information and turbine serial number.

Date/Time Displays total hours of ventilator operation and date/time configuration.

Fi02 Monitor Calibration Allows calibration of internal oxygen sensor.

(Comprehensive & Standard models only).

Vent Set-up: Allows setting of these functions:

Low Min Vol OFF Enable or disable an "OFF" setting

Panel Lock Enable or disable the front panel lock switch.

Fi02 Monitor Turns the Fi02 monitor on or off. (Comprehensive & Standard models only).

Altitude units of measure Toggles between feet and meters for the altitude setting.

Altitude setting Allows setting of altitude for accurate volume measurement.

Language buttons Select the desired language for the front panel.

Video Normal/Inverse Reverses the color configuration of the graphic interface.

For a complete explanation of each function, refer to the Vela Service Manual (P/N L1534).

* Denotes function for use by trained Service technician.

Page 17: Vela User™s Guide...NPPV SIMV NPPV AP PSV NPPV A/C olume A/C MODE SELECT APNEA MODE lume Setting the Ventilation Breath Type and Mode 1. Touch the Mode Indicator to open the mode

13 Vela User�s Guide L1536 Rev. C

Fi02 Monitor Calibration

When the Fi02 Mon Calibration button is touched, the calibration menu appears. You have a choice of doing an ambi-ent air calibration or a 100% oxygen calibration. Either can be done on or off a patient; however, be certain that thepatient can tolerate room air or 100% oxygen for the calibration procedure, which takes approximately 4 minutes tocomplete.

To exit the Fi02 Calibration screen, touch the EXIT button.

Fi02 Monitor Calibration

Page 18: Vela User™s Guide...NPPV SIMV NPPV AP PSV NPPV A/C olume A/C MODE SELECT APNEA MODE lume Setting the Ventilation Breath Type and Mode 1. Touch the Mode Indicator to open the mode

14 Vela User�s Guide L1536 Rev. C

This page intentionally left blank.

Page 19: Vela User™s Guide...NPPV SIMV NPPV AP PSV NPPV A/C olume A/C MODE SELECT APNEA MODE lume Setting the Ventilation Breath Type and Mode 1. Touch the Mode Indicator to open the mode

15 Vela User�s Guide L1536 Rev. C

New Patient Set-Up

1. Power on the ventilator and perform operational verification testing asdescribed in Chapter 2 of your Operator's Manual.

2. Select "NEW PATIENT". Touch "PATIENT ACCEPT"

3. Select Active or Passive Humidification.

4. Enter patient ID if desired.

5. Select �LEAK COMP� ON/OFF. Note: Default for NPPV A/C, NPPV SIMV; NPPV CPAP PSV; �LEAK COMPON�

6. Touch "SETUP ACCEPT"

The Set-up screen can be accessed at any time by pressing the "Setup" button on the bottom right corner of the touch screen.

PATIENT ACCEPT

NEWPATIENT

RESUMECURRENT

PATIENT SELECT

PATIENT

SETUP ACCEPT

IDENTIFICATION

ACTIVE

ONLEAK COMP

ON

HUMIDIFIER

Selecting "NEW PATIENT" clears all trends and saved loops, and sets all controls todefault values. Selecting "RESUME CURRENT" resumes ventilation at previous con-trol settings.

Touch the Patient ID box to open a virtual keyboard and use Touch-Turn-TouchTM/Touch-Turn-AcceptTM to enter alphanumeric characters.

New Patient Set-up

Page 20: Vela User™s Guide...NPPV SIMV NPPV AP PSV NPPV A/C olume A/C MODE SELECT APNEA MODE lume Setting the Ventilation Breath Type and Mode 1. Touch the Mode Indicator to open the mode

16 Vela User�s Guide L1536 Rev. C

This page intentionally left blank.

Page 21: Vela User™s Guide...NPPV SIMV NPPV AP PSV NPPV A/C olume A/C MODE SELECT APNEA MODE lume Setting the Ventilation Breath Type and Mode 1. Touch the Mode Indicator to open the mode

17 Vela User�s Guide L1536 Rev. C

MODE ACCEPT

CPAP PSV

APRV BiPhasic

APNEA SETTINGS

Pressure

PressureSIMV

VolumeSIMV

PressureA/C

PRVC SIMV

PRVCA/C

NPPV SIMV

NPPV CPAP PSV

NPPVA/C

VolumeA/C

MODE SELECT

APNEA MODE

Volume

Setting the Ventilation Breath Type and Mode1. Touch the Mode Indicator to open the mode window.

2. Select the desired mode and set the primary controls.

3. Touch "MODE ACCEPT" to accept the new mode and control settings.

4. Advanced settings and alarm limits may also be adjusted at this time. The buttons that open the advanced settingand alarm limits windows are located in the lower right hand corner of the touch screen.

Setting the VentilationBreath Type and Mode

Page 22: Vela User™s Guide...NPPV SIMV NPPV AP PSV NPPV A/C olume A/C MODE SELECT APNEA MODE lume Setting the Ventilation Breath Type and Mode 1. Touch the Mode Indicator to open the mode

18 Vela User�s Guide L1536 Rev. C

This page intentionally left blank.

Page 23: Vela User™s Guide...NPPV SIMV NPPV AP PSV NPPV A/C olume A/C MODE SELECT APNEA MODE lume Setting the Ventilation Breath Type and Mode 1. Touch the Mode Indicator to open the mode

19 Vela User�s Guide L1536 Rev. C

Monitored Parameters

Set Main Screen Monitored Parameters by using theTouch-Turn-TouchTM/Touch-Turn-AcceptTM technique.

Main Screen MonitorsFive monitored parameters are continuously

displayed to the left of the graphics display.Selections are made from a scrolling menu. Monitored parameters appearing on the

main screen may be different from those that appear on the optional loops screen.

Monitored Parameters

Page 24: Vela User™s Guide...NPPV SIMV NPPV AP PSV NPPV A/C olume A/C MODE SELECT APNEA MODE lume Setting the Ventilation Breath Type and Mode 1. Touch the Mode Indicator to open the mode

20 Vela User�s Guide L1536 Rev. C

Monitored ParametersTo configure an extended display for easy charting,

LOOP

MANEUVER

SCREEN SELECT

MONITOR

EXTENDEDFUNCTIONS

MAIN

TRENDS

1. Touch the Screen Indicator in the top center of the Main Screen display.

2. The Screen Select box will display.

3. Select MONITOR from the selection box that appears.

Page 25: Vela User™s Guide...NPPV SIMV NPPV AP PSV NPPV A/C olume A/C MODE SELECT APNEA MODE lume Setting the Ventilation Breath Type and Mode 1. Touch the Mode Indicator to open the mode

21 Vela User�s Guide L1536 Rev. C

Monitored Parameters

18.5mLVte

0.0L

Spon Ve

0cmH20

Ppeak

0mLVti

0.0bmpRate

0.00cmH20

Pmean

26.7mL

Spon Vt

0.0bmp

Spon Rate

0cmH20PEEP

0.0mL

Mand Vt

0secTi

8PSIG

02 Regulated

0.0L

Ve

0.00secTe

0%

Fi02

A 15-window display is configurable from a scrolling menu. Use the Touch-Turn-TouchTM/Touch-Turn-AcceptTM

technique to configure this display.

Page 26: Vela User™s Guide...NPPV SIMV NPPV AP PSV NPPV A/C olume A/C MODE SELECT APNEA MODE lume Setting the Ventilation Breath Type and Mode 1. Touch the Mode Indicator to open the mode

22 Vela User�s Guide L1536 Rev. C

This page intentionally left blank.

Page 27: Vela User™s Guide...NPPV SIMV NPPV AP PSV NPPV A/C olume A/C MODE SELECT APNEA MODE lume Setting the Ventilation Breath Type and Mode 1. Touch the Mode Indicator to open the mode

23 Vela User�s Guide L1536 Rev. C

GraphicsConfigure main screen graphics for scale and sweep speed.

1. Touch the vertical or horizontal axis to highlight. 2. Turn the data dial to adjust scale or sweep speed.

3. Touch the axis again or press accept to confirm the change.

Graphics

Page 28: Vela User™s Guide...NPPV SIMV NPPV AP PSV NPPV A/C olume A/C MODE SELECT APNEA MODE lume Setting the Ventilation Breath Type and Mode 1. Touch the Mode Indicator to open the mode

24 Vela User�s Guide L1536 Rev. C

GraphicsConfigure the optional Loops Screen

1. Touch the vertical or horizontal axis to highlight. 2. Turn the data dial to adjust the scale.

3. Touch the axis again or press accept to confirm

the change.

250 500 750

Page 29: Vela User™s Guide...NPPV SIMV NPPV AP PSV NPPV A/C olume A/C MODE SELECT APNEA MODE lume Setting the Ventilation Breath Type and Mode 1. Touch the Mode Indicator to open the mode

25 Vela User�s Guide L1536 Rev. C

Graphics

The FREEZE button freezes the current screenuntil pressed again. When the screen is frozenyou can scroll through displayed waveforms orloops using the Data Dial to move the cursor.

250 500 750

Cursor, currentlyoverlays the "X"axis at Zero

Flag showing Xand Y values atvarious pointsalong the looptracingDashed

Cursor Line

Flow/VolumeLoop Tracing

270

0.0

A flow/volume loop in "freeze" mode is depictedbelow. As the dotted line cursor traces the "frozen"loop curve, flags display the values along the curveof the loop.

Page 30: Vela User™s Guide...NPPV SIMV NPPV AP PSV NPPV A/C olume A/C MODE SELECT APNEA MODE lume Setting the Ventilation Breath Type and Mode 1. Touch the Mode Indicator to open the mode

26 Vela User�s Guide L1536 Rev. C

GraphicsSaving loops

1. Press the "Freeze" button to freeze the graphics display. 2. Press "Save Loop"

3. Saved loops will appear with a time reference. A total of 4 loops can be saved at any time. The oldest loop is discarded when the 5th loop is saved.

250

270

500 750

0.0

Page 31: Vela User™s Guide...NPPV SIMV NPPV AP PSV NPPV A/C olume A/C MODE SELECT APNEA MODE lume Setting the Ventilation Breath Type and Mode 1. Touch the Mode Indicator to open the mode

27 Vela User�s Guide L1536 Rev. C

GraphicsCreate Reference Loops

1. Press the "Freeze" button to freeze the graphics display.

2. Touch the saved loop you want as a reference.

4. Press the "Freeze" button to return to live loops display over the reference loop.

Discontinue Reference Loops

To discontinue the reference, press the "Freeze" button to freeze thegraphics display and press the "Ref Loop On" button to turn off the refer-ence loop. Press "Freeze" again to return to a live loop screen.

3. Press the "Ref Loop Off" button to toggle the reference loop on.

Page 32: Vela User™s Guide...NPPV SIMV NPPV AP PSV NPPV A/C olume A/C MODE SELECT APNEA MODE lume Setting the Ventilation Breath Type and Mode 1. Touch the Mode Indicator to open the mode

28 Vela User�s Guide L1536 Rev. C

This page intentionally left blank.

Page 33: Vela User™s Guide...NPPV SIMV NPPV AP PSV NPPV A/C olume A/C MODE SELECT APNEA MODE lume Setting the Ventilation Breath Type and Mode 1. Touch the Mode Indicator to open the mode

29 Vela User�s Guide L1536 Rev. C

Synchronized Nebulizer

A high pressure oxygen source gas connection is required to power the in-line nebulizer. Nebulizer flow delivery is synchronized with inspiration.Nebulization lasts for up to 60 minutes and is user adjustable in incrementsof one minute. Pressing the nebulizer button again ends nebulization.

Caution: Nebulizer output is not volume compensated during volume controlbreaths. Delivered volumes and peak inspiratory pressures will increase dur-ing nebulization. To ensure consistent tidal volume delivery, tidal volumeshould be reduced for the duration of the treatment. Nebulizer output isapproximately 50 ml per half second of inspiratory time. Tidal volume is unaf-fected during pressure control breaths.

Fi02 will increase slightly during nebulization. Delivered Fi02 during nebulization can be estimated using the following calculation;

New Fi02 = [(Vt x Fi02) + (0.1 x Ti)][Vt + (0.1 x Ti)]

NEBULIZER100%

O2

MANUALBREATH

EXPHOLD

FREEZE INSPHOLD

ALARMSILENCE

ALARMRESET

2

2

Synchronized Nebulizer

Page 34: Vela User™s Guide...NPPV SIMV NPPV AP PSV NPPV A/C olume A/C MODE SELECT APNEA MODE lume Setting the Ventilation Breath Type and Mode 1. Touch the Mode Indicator to open the mode

30 Vela User�s Guide L1536 Rev. C

This page intentionally left blank.

Page 35: Vela User™s Guide...NPPV SIMV NPPV AP PSV NPPV A/C olume A/C MODE SELECT APNEA MODE lume Setting the Ventilation Breath Type and Mode 1. Touch the Mode Indicator to open the mode

31 Vela User�s Guide L1536 Rev. C

Oxygen Computer Chart

To Find O2 Input Flow:

1. Select desired FiO2 on horizontal axis.

2. Project up to current minute volume (Ve from monitor display).

3. Project horizontally to left vertical axis andread oxygen flow.

To Find O2 Concentration:

1. Select current O2 input flow on vertical axis.

2. Project horizontally right to current minutevolume (Ve from monitor display).

3. Project vertically down to horizontal axisand read oxygen concentration.

30

25

20

15

10

5

0.21 .30 .40 .50 .60 .70 .80 .90 1.0

FiO2

1234

6

10

14

18Ve = 20

Oxy

gen

Inpu

t flo

w (

L/m

in)

12

8

16

Oxygen Computer Chart

Page 36: Vela User™s Guide...NPPV SIMV NPPV AP PSV NPPV A/C olume A/C MODE SELECT APNEA MODE lume Setting the Ventilation Breath Type and Mode 1. Touch the Mode Indicator to open the mode

32 Vela User�s Guide L1536 Rev. C

This page intentionally left blank.

Page 37: Vela User™s Guide...NPPV SIMV NPPV AP PSV NPPV A/C olume A/C MODE SELECT APNEA MODE lume Setting the Ventilation Breath Type and Mode 1. Touch the Mode Indicator to open the mode

33 Vela User�s Guide L1536 Rev. C

Contact Information

VIASYS Healthcare Customer Care-Technical ServiceHours: 7:30 AM to 4:30 PM (PST) M-FPhone: (760) 778-7200Fax: (760) 778-7377

VIASYS Healthcare Customer Care HelplineHours: 24 Hours, 7 days a weekPhone: (800) 934-2473Fax: (760) 778-7377

VIASYS Healthcare- Critical Care Division1100 Bird Center DrivePalm Springs, CA 92262-8099 U.S.A.Phone: (760) 778-7200, (800) 328-4139Fax: (760) 778-7274

www.ViasysCriticalCare.com

Contact Information

Page 38: Vela User™s Guide...NPPV SIMV NPPV AP PSV NPPV A/C olume A/C MODE SELECT APNEA MODE lume Setting the Ventilation Breath Type and Mode 1. Touch the Mode Indicator to open the mode

34 Vela User�s Guide L1536 Rev. C

Notes

Page 39: Vela User™s Guide...NPPV SIMV NPPV AP PSV NPPV A/C olume A/C MODE SELECT APNEA MODE lume Setting the Ventilation Breath Type and Mode 1. Touch the Mode Indicator to open the mode

35 Vela User�s Guide L1536 Rev. C

Notes

Page 40: Vela User™s Guide...NPPV SIMV NPPV AP PSV NPPV A/C olume A/C MODE SELECT APNEA MODE lume Setting the Ventilation Breath Type and Mode 1. Touch the Mode Indicator to open the mode

L15

36

Rev. C