PROPOSED RESIDENCE FOR: DAWODU & AKINSHOLA

5
PROPOSED NEW RESIDENCE FOR AT COPYRIGHT HOTONDO PTY LTD Rev Amendment Date A 23/09/21 DATE ........./.........../................. BUILDER ....................................... DATE ........./.........../................. CLIENT ....................................... PRELIMINARY DRAWINGS Drawn VN-EM THIS DRAWING REMAINS THE PROPERTY OF HOTONDO PTY LTD AND IS PROVIDED FOR THE USE AS DESCRIBED AND MAY NOT BE USED OR REPRODUCED IN WHOLE OR IN PART WITHOUT WRITTEN CONSENT DAWODU & AKINSHOLA LOT 78 DP 1274510 NO. 16 MOUNTAIN VISTA ORANGE, NSW 2800 SCALE DATE DRAWN DWG No. JOB No. 00 13/10/21 VN-GB SHEET SIZE A3 000224 PRELIMINARY MODIFIED KALARA 253 BASIX CERT. No. PLAN TITLE FACADE TRADITIONAL B 07/10/21 WORKING DRAWINGS VN-EM C 13/10/21 VO1 VN-GB COVER SHEET SPECIFICATIONS GENERAL - IT IS RESPONSIBILITY OF BUILDER TO VERIFY ALL DOCUMENTS AS TO THEIR ACCURACY AND SUITABILITY - PLANS TO BE READ IN CONJUNCTION WITH ENGINEER'S DETAILS WHERE APPLICABLE - NCC - NATIONAL CONSTRUCTION CODE - VOLUME 2 - HOUSING PROVISIONS STATUTORY REQUIREMENTS - ALL WORK TO BE CARRIED OUT IN ACCORDANCE WITH THE NCC CONDITIONS IMPOSED BY LOCAL AUTHORITY, & COMMITMENTS NOTED IN RELEVANT BASIX CERTIFICATE - THE BUILDER IS TO COMPLY WITH REQUIREMENTS OF ALL LEGALLY CONSTITUTED AUTHORITIES HAVING JURISDICTION OVER BUILDING WORKS AND PROVISIONS OF THE HOME BUILDING ACT. - BUILDER SHALL PROVIDE TEMPORARY TOILET FACILITIES FOR THE USE OF THE SUBCONTRACTORS NCC REQUIREMENTS - ALL EARTHWORKS SHALL BE IN ACCORDANCE WITH ENGINEER'S DETAILS & PART 3.1.1 OF NCC. ALL EXCAVATIONS & UNDERFLOOR FILL SHALL BE IN ACCORDANCE WITH ENGINEER'S DETAILS & PART 3.2.2 OF NCC - PRIMARY BUILDING ELEMENTS TO BE PROTECTED FROM SUBTERRENEAN TERMITES IN ACCORDANCE WITH PART 3.1.4 OF NCC - PROVIDE ADEQUATE CROSS VENTILATION TO SPACE UNDER SUSPENDED GROUND FLOORS IN ACCORDANCE WITH PART 3.4.1 OF NCC - STORMWATER DRAINAGE SHALL BE CARRIED OUT IN ACCORDANCE WITH PART 3.1.3 OF NCC - ALL TIMBER FRAMEWORK SHALL COMPLY WITH PART 3.4.1 OF NCC OR AS1684 - ROOF TRUSSES SHALL BE DESIGNED IN ACCORDANCE WITH AS1720 & INSTALLED IN ACCORDANCE TO MANUFACTURER'S SPECIFICATIONS - STRIP & SHEET FLOORING SHALL BE INSTALLED IN ACCORDANCE WITH AS1684 - STEEL FRAMING SHALL BE IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS & PART 3.4.2 OF NCC - ALL ROOF CLADDING SHALL COMPLY WITH PART 3.5.1 OF NCC, & INSTALLED IN ACCORDANCE TO MANUFACTURER'S SPECIFICATIONS - GUTTERS & DOWNPIPES SHALL BE IN ACCORDANCE WITH PART 3.5.3 OF NCC - SARKING SHALL COMPLY WITH AS/NZS4200.1 & 2 - FLASHING SHALL COMPLY WITH EITHER AS4773 OR AS3700 - CLAY BRICK WORK SHALL COMPLY WITH EITHER AS4773 OR AS3700 - CONCRETE BLOCK WORK SHALL BE CONSTRUCTED IN ACCORDANCE WITH EITHER AS4773 OR AS3700 - AUTOCLAVED AERATED CONCRETE PRODUCTS SHALL E INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS AS 5416.1 - DAMP PROOF COURSES & CAVITY VENTILATION SHALL COMPLY WITH EITHER AS4773 OR AS3700 - MORTAR & JOINT TOLERANCES SHALL BE IN ACCORDANCE WITH EITHER AS4773 OR AS3700 - MASONRY ACCESSORIES SHALL COMPLY WITH EITHER AS4773 OR AS3700 APPROPRIATE TIES SHALL BE PROVIDED TO ARTICULATED MASONRY JOINTS - LINTELS USED TO SUPPORT BRICKWORK OVER OPENINGS & BE PROTECTED FROM CORROSION SHALL COMPLY WITH EITHER AS4773 OR AS3700 - MASONRY VENEER SHALL COMPLY WITH PART 3.3.5 OF NCC - ENGAGED PIERS IN SINGLE LEAF MASONRY WALLS SHALL BE CONSTRUCTED IN ACCORDAANCE WITH EITHER AS4773 OR AS3700 - INTERNAL WET AREAS & BALCONIES OVER HABITABLE ROOMS TO BE WATERPROOFED IN ACCORDANCE WITH PART 3.8.1 OF NCC. WET AREA WALL LINING TO BE FIXED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS - ALL TIMBER DOOR & DOOR SETS SHALL BE MANUFACTURED IN ACCORDANCE WITH AS2688 & AS2689 UNLESS NOTED OTHERWISE IN THE SCHEDULE OF WORKS - WINDOWS & DOORS SHALL BE MANUFACTURED & INSTALLED IN ACCORDANCE WITH AS 2047 - ALL GLAZING SHALL COMPLY WITH PART 3.6 OF NCC - STAIR & RAMP CONSTRUCTION SHALL BE IN ACCORDANCE WITH PART 3.9.1 OF NCC - BALUSTRADES SHALL BE IN ACCORDANCE WITH PART 3.9.2 OF NCC - ALL PLUMBING SHALL COMPLY WITH REQUIREMENTS OF RELEVANT SUPPLY AUTHORITY & AS3500, & BE CARRIED OUT BY A LICENSED PLUMBER - ALL ELECTRICAL WORK SHALL COMPLY WITH REQUIREMENTS OF RELEVANT SUPPLY AUTHORITY & AS3000 & BE CARRIED OUT BY LICENSED ELECTRICIAN - ALL GAS INSTALLATIONS SHALL COMPLY WITH REQUIREMENTS OF RELEVANT SUPPLY AUTHORITY, & BE CARRIED OUT BY A LICENSED GAS FITTER - PROVIDE & INSTALL HARD WIRED SMOKE ALRAMS IN ACCORDANCE WITH AS3786 & PART 3.7.5 OF NCC - INSTALLATION OF WALL & FLOOR TILES SHALL BE IN ACCORDANCE WITH AS3958.1 - BUILDING TO BE SEALED TO THE REQUIREMENTS OF PART 3.12.3 OF NCC, INCLUDING CHIMNEY'S, FLUES, ROOF LIGHTS, EXTERNAL WINDOWS & DOORS, EXHAUST FANS, ROOF, WALLS, & FLOORS. - SERVICES ARE TO BE INSTALLED TO THE REQUIREMENTS OF NSW PART 3.12.5 OF BCA, INCLUDING HOT WATER SUPPLY, INSULATION OF SERVICES, CENTRAL HEATING WATER PIPING, HEATING & COOLING DUCTWORK - MECHANICAL VENTILATION IS TO BE INSTALLED IN ACCORDANCE WITH PART 3.8.5 OF NCC - INWARD SWINGING WC DOORS ARE TO BE FITTED WITH LIFT OFF HINGES TO COMPLY WITH PART 3.8.3.3 OF NCC - CONDENSATION MANAGEMENT TO COMPLY WITH PART 3.8.7 OF NCC - FIRE HAZARD PROPERTIES TO COMPLY WITH PART 3.7.1.2 OF NCC - WALL CLADDING TO COMPLY WITH PART 3.5.4 OF NCC Drawing List Sheet No. 00 01-1 01-2 01-3 02-1 02-2 02-3 03-1 03-2 04 05-1 05-2 05-3 06 07-1 07-2 07-3 08 09-1 09-2 09-3 Sheet Name COVER SHEET SITE PLAN SHADOW DIAGRAM SHADOW DIAGRAM GROUND FLOOR PLAN FIRST FLOOR PLAN ROOF PLAN ELEVATIONS ELEVATIONS PERSPECTIVES SECTION SECTION DETAILS STAIRS LAYOUT SLAB LAYOUT REDACTED PLAN BRICKWORK SETOUT KITCHEN DETAILS WET AREA DETAILS WET AREA DETAILS FITOUT AREA DETAILS PROPOSED RESIDENCE FOR: DAWODU & AKINSHOLA LOT 78 DP 1274510 NO. 16 MOUNTAIN VISTA ORANGE, NSW 2800

Transcript of PROPOSED RESIDENCE FOR: DAWODU & AKINSHOLA

PROPOSED NEW RESIDENCE FOR

AT

COPYRIGHT HOTONDO PTY LTDRev Amendment DateA 23/09/21

DATE ........./.........../.................

BUILDER .......................................

DATE ........./.........../.................

CLIENT .......................................

PRELIMINARY DRAWINGS

DrawnVN-EM

THIS DRAWING REMAINS THE PROPERTY OF HOTONDO PTY LTD AND IS PROVIDEDFOR THE USE AS DESCRIBED AND MAY NOT BE USED OR REPRODUCED IN WHOLE

OR IN PART WITHOUT WRITTEN CONSENT

DAWODU & AKINSHOLA

LOT 78 DP 1274510NO. 16 MOUNTAIN VISTAORANGE, NSW 2800

SCALE

DATEDRAWN

DWG No.JOB No.00

13/10/21VN-GB

SHEET SIZE A3

000224

PRELIMINARY

MODIFIED KALARA 253BASIX CERT. No.

PLAN

TITLE

FACADE

TRADITIONALB 07/10/21WORKING DRAWINGS VN-EMC 13/10/21VO1 VN-GB

COVER SHEET

SPECIFICATIONSGENERAL- IT IS RESPONSIBILITY OF BUILDER TO VERIFY ALL DOCUMENTS AS TO THEIR ACCURACY AND SUITABILITY- PLANS TO BE READ IN CONJUNCTION WITH ENGINEER'S DETAILS WHERE APPLICABLE- NCC - NATIONAL CONSTRUCTION CODE - VOLUME 2 - HOUSING PROVISIONSSTATUTORY REQUIREMENTS- ALL WORK TO BE CARRIED OUT IN ACCORDANCE WITH THE NCC CONDITIONS IMPOSED BY LOCAL AUTHORITY, & COMMITMENTS NOTED IN RELEVANT BASIX CERTIFICATE- THE BUILDER IS TO COMPLY WITH REQUIREMENTS OF ALL LEGALLY CONSTITUTED AUTHORITIES HAVING JURISDICTION OVER BUILDING WORKS AND PROVISIONS OF THE HOME BUILDING ACT.- BUILDER SHALL PROVIDE TEMPORARY TOILET FACILITIES FOR THE USE OF THE SUBCONTRACTORSNCC REQUIREMENTS- ALL EARTHWORKS SHALL BE IN ACCORDANCE WITH ENGINEER'S DETAILS & PART 3.1.1 OF NCC. ALL EXCAVATIONS & UNDERFLOOR FILL SHALL BE IN ACCORDANCE WITH ENGINEER'S DETAILS & PART 3.2.2 OF NCC- PRIMARY BUILDING ELEMENTS TO BE PROTECTED FROM SUBTERRENEAN TERMITES IN ACCORDANCE WITH PART 3.1.4 OF NCC- PROVIDE ADEQUATE CROSS VENTILATION TO SPACE UNDER SUSPENDED GROUND FLOORS IN ACCORDANCE WITH PART 3.4.1 OF NCC- STORMWATER DRAINAGE SHALL BE CARRIED OUT IN ACCORDANCE WITH PART 3.1.3 OF NCC- ALL TIMBER FRAMEWORK SHALL COMPLY WITH PART 3.4.1 OF NCC OR AS1684- ROOF TRUSSES SHALL BE DESIGNED IN ACCORDANCE WITH AS1720 & INSTALLED IN ACCORDANCE TO MANUFACTURER'S SPECIFICATIONS- STRIP & SHEET FLOORING SHALL BE INSTALLED IN ACCORDANCE WITH AS1684- STEEL FRAMING SHALL BE IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS & PART 3.4.2 OF NCC- ALL ROOF CLADDING SHALL COMPLY WITH PART 3.5.1 OF NCC, & INSTALLED IN ACCORDANCE TO MANUFACTURER'S SPECIFICATIONS- GUTTERS & DOWNPIPES SHALL BE IN ACCORDANCE WITH PART 3.5.3 OF NCC- SARKING SHALL COMPLY WITH AS/NZS4200.1 & 2- FLASHING SHALL COMPLY WITH EITHER AS4773 OR AS3700- CLAY BRICK WORK SHALL COMPLY WITH EITHER AS4773 OR AS3700- CONCRETE BLOCK WORK SHALL BE CONSTRUCTED IN ACCORDANCE WITH EITHER AS4773 OR AS3700- AUTOCLAVED AERATED CONCRETE PRODUCTS SHALL E INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS AS 5416.1- DAMP PROOF COURSES & CAVITY VENTILATION SHALL COMPLY WITH EITHER AS4773 OR AS3700- MORTAR & JOINT TOLERANCES SHALL BE IN ACCORDANCE WITH EITHER AS4773 OR AS3700- MASONRY ACCESSORIES SHALL COMPLY WITH EITHER AS4773 OR AS3700 APPROPRIATE TIES SHALL BE PROVIDED TO ARTICULATED MASONRY JOINTS- LINTELS USED TO SUPPORT BRICKWORK OVER OPENINGS & BE PROTECTED FROM CORROSION SHALL COMPLY WITH EITHER AS4773 OR AS3700- MASONRY VENEER SHALL COMPLY WITH PART 3.3.5 OF NCC- ENGAGED PIERS IN SINGLE LEAF MASONRY WALLS SHALL BE CONSTRUCTED IN ACCORDAANCE WITH EITHER AS4773 OR AS3700- INTERNAL WET AREAS & BALCONIES OVER HABITABLE ROOMS TO BE WATERPROOFED IN ACCORDANCE WITH PART 3.8.1 OF NCC. WET AREA WALL LINING TO BE FIXED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS- ALL TIMBER DOOR & DOOR SETS SHALL BE MANUFACTURED IN ACCORDANCE WITH AS2688 & AS2689 UNLESS NOTED OTHERWISE IN THE SCHEDULE OF WORKS- WINDOWS & DOORS SHALL BE MANUFACTURED & INSTALLED IN ACCORDANCE WITH AS 2047- ALL GLAZING SHALL COMPLY WITH PART 3.6 OF NCC- STAIR & RAMP CONSTRUCTION SHALL BE IN ACCORDANCE WITH PART 3.9.1 OF NCC- BALUSTRADES SHALL BE IN ACCORDANCE WITH PART 3.9.2 OF NCC- ALL PLUMBING SHALL COMPLY WITH REQUIREMENTS OF RELEVANT SUPPLY AUTHORITY & AS3500, & BE CARRIED OUT BY A LICENSED PLUMBER- ALL ELECTRICAL WORK SHALL COMPLY WITH REQUIREMENTS OF RELEVANT SUPPLY AUTHORITY & AS3000 & BE CARRIED OUT BY LICENSED ELECTRICIAN- ALL GAS INSTALLATIONS SHALL COMPLY WITH REQUIREMENTS OF RELEVANT SUPPLY AUTHORITY, & BE CARRIED OUT BY A LICENSED GAS FITTER- PROVIDE & INSTALL HARD WIRED SMOKE ALRAMS IN ACCORDANCE WITH AS3786 & PART 3.7.5 OF NCC- INSTALLATION OF WALL & FLOOR TILES SHALL BE IN ACCORDANCE WITH AS3958.1- BUILDING TO BE SEALED TO THE REQUIREMENTS OF PART 3.12.3 OF NCC, INCLUDING CHIMNEY'S, FLUES, ROOF LIGHTS, EXTERNAL WINDOWS & DOORS, EXHAUST FANS, ROOF, WALLS, & FLOORS.- SERVICES ARE TO BE INSTALLED TO THE REQUIREMENTS OF NSW PART 3.12.5 OF BCA, INCLUDING HOT WATER SUPPLY, INSULATION OF SERVICES, CENTRAL HEATING WATER PIPING, HEATING & COOLING DUCTWORK- MECHANICAL VENTILATION IS TO BE INSTALLED IN ACCORDANCE WITH PART 3.8.5 OF NCC- INWARD SWINGING WC DOORS ARE TO BE FITTED WITH LIFT OFF HINGES TO COMPLY WITH PART 3.8.3.3 OF NCC- CONDENSATION MANAGEMENT TO COMPLY WITH PART 3.8.7 OF NCC- FIRE HAZARD PROPERTIES TO COMPLY WITH PART 3.7.1.2 OF NCC- WALL CLADDING TO COMPLY WITH PART 3.5.4 OF NCC

Drawing List

Sheet No.

0001-101-201-302-102-202-303-103-20405-105-205-30607-107-207-30809-109-209-3

Sheet Name

COVER SHEETSITE PLANSHADOW DIAGRAMSHADOW DIAGRAMGROUND FLOOR PLANFIRST FLOOR PLANROOF PLANELEVATIONSELEVATIONSPERSPECTIVESSECTIONSECTIONDETAILSSTAIRS LAYOUTSLAB LAYOUTREDACTED PLANBRICKWORK SETOUTKITCHEN DETAILSWET AREA DETAILSWET AREA DETAILSFITOUT AREA DETAILS

PROPOSED RESIDENCE FOR:DAWODU & AKINSHOLALOT 78 DP 1274510NO. 16 MOUNTAIN VISTAORANGE, NSW 2800

PROPOSED NEW RESIDENCE FOR

AT

COPYRIGHT HOTONDO PTY LTDRev

AmendmentDate

A23/09/21

DATE ........./.........../.................

BUILDER .......................................

DATE ........./.........../.................

CLIENT .......................................

PRELIMINARY DRAWINGS

DrawnVN-EM

THIS DRAWING REMAINS THE PROPERTY OF HOTONDO PTY LTD AND IS PROVIDED

FOR THE USE AS DESCRIBED AND MAY NOT BE USED OR REPRODUCED IN WHOLE

OR IN PART WITHOUT W

RITTEN CONSENT

DAWODU & AKINSHOLA

LOT 78 DP 1274510NO. 16 MOUNTAIN VISTAORANGE, NSW

2800

SCALE

DATEDRAW

NDW

G No.JOB No.

01-1

13/10/21VN-GB

SHEET SIZEA3 1:200

000224

PRELIMINARY

MODIFIED KALARA 253BASIX CERT. No.

PLAN

TITLE

FACADETRADITIONALB

07/10/21W

ORKING DRAWINGS

VN-EMC

13/10/21VO1

VN-GB

SITE PLAN 20m MAXIMUM(UNLESS STATED OTHERW

ISE ON PROJECT PLAN)

MINIMUM1.5m

1500 STAR PICKETS

500 MINIMUM 500-600

SEDIM

ENT FEN

CE

SECTION A-A

A

A

ELEVATION

PLAN

FLOW

STAR PICKETS AT MAXIMUM3.0m SPACINGS

SELF SUPPORTINGGEOTEXTILE

DIRECTION OF FLOW

ON SOIL - 150x100 TRENCHW

ITH COMPACTED BACKFILLON ROCK - SET INTOSURFACE CONCRETE

DISTURBED AREA

UNDISTURBED AREA

SD6-8

1.5m STAR PICKETS ATMAXIMUM 3.0m SPACINGS

Construction N

otes1. Construct sediment fence as close as possible to parallel with the contours of the site.2. Drive 1.5m long star pickets into ground, 3.0m apart.3. Dig a 150mm deep trench along the upslope line of the fence for the bottom of the fabric to be

entrenched.4. Backfill trench over base of fabric.5. Fix self-supporting geotextile to upslope side of posts with wire ties or as recommended by

geotextile manufacturer.6. Join sections of fabric at support posts with a 150mm overlap.

NOTE:-ALL LEVELS SHOW

N ARE NOMINAL-FINAL LEVELS ARE TO BE DETERMINED ON-SITE TO BEST SUIT GRADE & FALLS

STANDARD NOTES1. ALL W

RITTEN DIMENSION TAKEPRECEDENCE OVER SCALE.2. ALL ROOF BEAMS. LINTELS ANDBRICKW

ORK ANGLES TO TRUSS/WALL

FRAME MANUFACTURER'SSPECIFICATIONS AND ENGINEERSVERIFICATION.3. W

C DOORS TO COMPLY WITH NCC VOL 2

PT 3.8.3.3.4. ALL W

ET AREAS TO BE COMPLETED INACCORDANCE W

ITH NCC VOL 2 PT 3.8.1.5. ENGINEER DESIGNED - PREFABRICATEDTIMBER ROOF TRUSSES AS PERMANUFACTURER'S SPECIFICATIONS. (600CTS UNLESS NOTED OTHERW

ISE).6. 90mm PREFABRICATED TIMBER W

ALLFRAMES AS PER MANUFACTURER'SSPECIFICATIONS, U.N.O.7. BUILDER & TRADES ARE TO CONFIRMALL MEASUREMENTS, DETAILS &SPECIFICATIONS PRIOR TO SET-OUT BEORDERING OF MATERIALS.8. REPORT ANY ERRORS FORCLARIFICATION/CORRECTION AS NORESPONSIBILITY W

ILL BE TAKEN AFTERCONSTRUCTION HAS COMMENCED.9. ALL ELECTRICAL APPLIANCE &PLUMBING SYMBOLS ARE DIAGRAMMATICONLY. REFER TO BUILDERSSPECIFICATION FOR DETAILS OF ALLFIXTURES.10. SIZE AND LOCATION OF DOW

NPIPES TOBE CONFIRMED ON SITE BY BUILDER.11. ALL W

ORK TO BE CONSTRUCTED INACCORDANCE W

ITH THE BUILDING CODEOF AUSTRALIA AND RELEVANT TRADE ANDTECHNICAL MANUALS.

DP

DPDPDP

DPDP

DP

DP

6,078

5,309 5,161

4,9924,550

58,969

3,0006,000

51.33 m2

PORCHFFL @

874.21

METERBOXINST.HW

S

872 .6 38 72 .8 3 8 73 .1 0 8 73 .3 8

8 73 .6 5

8 72 .3 48 72 .4 8

8 72 .8 1

8 73 .6 8

8 74 .5 8

8 75 .5 2

8 76 .4 9

8 77 .4 8

8 78 .4 5

8 79 .3 6

8 80 .2 4

8 79 .6 4

8 78 .8 6

8 77 .9 1

8 77 .0 2

8 76 .1 7

8 75 .3 2

8 74 .4 8

8 73 .6 6

8 73 .11 8 73 .4 4

8 74 .2 1

8 74 .8 9

8 75 .7 4

8 76 .5 4

8 77 .3 7

8 78 .3 3

8 79 .0 38 78 .9 6

8 78 .1 3

8 77 .2 4

8 76 .4 1

8 75 .5 8

8 74 .8 5

8 74 .1 8

8 73 .6 3

8 7 3 .7 8

874 .3 7

8 75 .11

8 75 .7 7

8 76 .6 3

8 77 .4 8

8 78 .2 6

8 79 .0 0

R 57.62A 17.19

C 1 7 .1 2 5 1 8 °0 6 '2 5 "

279 °13 '50 "81.615

99 °13 '50 "78 .95

875.00 875.00

876.00 876.00

877.00 877.00

878.00878.00

879.00

879.00

880.00

9°48 '10 "3 .08RL 8 7 2 .6 2

D H & W I N G

B E N C H M A R K

(S M )(S M )(S M )

V A C A N T 21 6 1 6 mV A C A N T

7 880

VISTAMOUNTAIN

C O N C R E T ED R I V E W A Y

C O N C R E T ED R I V E W A Y

N B N P I TE L E C T R I C I T Y P I L L A R

S E W E R M A N H O L EW A T E R S U P P L Y

S E W E R J U N C T I O N

S E W E R M A N H O L ES E W E R J U N C T I O N

S T R E E T L I G H TW A T E R S U P P L Y

U P R I G H T 1 5 0 m m C O N C R E T EK E R B & G U T T E R

K E R BI N L E T P I T

GARAGEFFL @

874.13

CROSSOVER TOCOUNCIL

REQUIREMENTSDRIVEW

AY BYBUILDER

FFL @ 874.30

LOT 78PROPOSEDDW

ELLINGFFL @

875.67

SETOUT

SETBACK

SETBACK SETBACK

SETBACK

SETBACK

SETBACK TO B 'DRY

SETBACK

-570+202

+628-570

AREASLocation

GROUND FLOORGARAGEPORCHUPPER FLOOR

Area139.8836.542.8474.53253.79 m

2

AREA [m2 ON THE FLAT]124.07

AREA [m2 ON THE RAKE]134.60

ROOF AREAS (COLORBOND)

Site Area

Name

AreaPercentage Of

Area UsedBuilt Area (Garage,House, Alfresco & Porch)

179.26m²11.09%

Site Remaining1407.2m²

87.08%Driveway

29.54m²1.83%

Grand total: 31616 m

²100%

MOUNTAIN

1SITE PLAN1:200

PROPOSED NEW RESIDENCE FOR

AT

COPYRIGHT HOTONDO PTY LTDRev Amendment DateA 23/09/21

DATE ........./.........../.................

BUILDER .......................................

DATE ........./.........../.................

CLIENT .......................................

PRELIMINARY DRAWINGS

DrawnVN-EM

THIS DRAWING REMAINS THE PROPERTY OF HOTONDO PTY LTD AND IS PROVIDEDFOR THE USE AS DESCRIBED AND MAY NOT BE USED OR REPRODUCED IN WHOLE

OR IN PART WITHOUT WRITTEN CONSENT

DAWODU & AKINSHOLA

LOT 78 DP 1274510NO. 16 MOUNTAIN VISTAORANGE, NSW 2800

SCALE

DATEDRAWN

DWG No.JOB No.03-2

13/10/21VN-GB

SHEET SIZE A31:100

000224

PRELIMINARY

MODIFIED KALARA 253BASIX CERT. No.

PLAN

TITLE

FACADE

TRADITIONALB 07/10/21WORKING DRAWINGS VN-EMC 13/10/21VO1 VN-GB

ELEVATIONS

FLF2

CL

FLF1

876.000

875.005

CLFLF3

CL

3493

2636

4c

25c

13c

25c

2,400

2,400

300

2,440

6,614

450

450

450450

JAMES HARDIEHARDIPLANKSMOOTH 230

SELECTED COLORBONDROOF @ 22.5º PITCH

SELECTED FASCIAAND GUTTER

FLASHING

FACEBRICK

FACEBRICK

EAVES

EAVES

EAVESEAVES

1:100NORTH ELEVATION

874.210

873.780

874.370

BRICK PIER

ALUMINUM FRAMEDWINDOWS AND DOORS

FLF2

GFL

CL

8c

FL

25c

0c 4c

11c

25c

4c

11c

25c

-17c

2,486

2,440

450

450

450

450

JAMES HARDIEHARDIPLANKSMOOTH 230

SELECTED COLORBONDROOF @ 22.5º PITCH

SELECTED FASCIAAND GUTTER

FLASHING

FLASHING

FACE

BRIC

K

EAVES

EAVES

EAVES

EAVES

EAVES

1:100EAST ELEVATION

876.170

ALUMINUM FRAMEDWINDOWS AND DOORS

PROTECTION OF OPENABLE WINDOWS AS PER B.C.ACONDITION 3.9.2.5A WINDOW OPENING MUST BE PROVIDED WITH PROTECTION IF THE FLOOR BELOWTHE WINDOW IN A BEDROOM IS 2m OR MORE ABOVE THE SURFACE BENEATH.WHERE THE LOWEST LEVEL OF A WINDOW OPENING IS LESS THAN 1.7m ABOVE THEFLOOR, A KEYED LOCK MUST BE FITTED SO AS TO RESTRICT THE WINDOW OPENINGTO A MAX 125mm

PROPOSED NEW RESIDENCE FOR

AT

COPYRIGHT HOTONDO PTY LTDRev Amendment DateA 23/09/21

DATE ........./.........../.................

BUILDER .......................................

DATE ........./.........../.................

CLIENT .......................................

PRELIMINARY DRAWINGS

DrawnVN-EM

THIS DRAWING REMAINS THE PROPERTY OF HOTONDO PTY LTD AND IS PROVIDEDFOR THE USE AS DESCRIBED AND MAY NOT BE USED OR REPRODUCED IN WHOLE

OR IN PART WITHOUT WRITTEN CONSENT

DAWODU & AKINSHOLA

LOT 78 DP 1274510NO. 16 MOUNTAIN VISTAORANGE, NSW 2800

SCALE

DATEDRAWN

DWG No.JOB No.03-1

13/10/21VN-GB

SHEET SIZE A31:100

000224

PRELIMINARY

MODIFIED KALARA 253BASIX CERT. No.

PLAN

TITLE

FACADE

TRADITIONALB 07/10/21WORKING DRAWINGS VN-EMC 13/10/21VO1 VN-GB

ELEVATIONS

FLF1

CL

GFL

FLF3

CL

3493

9c

CL

1693

2293 2293

3493

1693

2293

3493

1693

-5c-12c

2,400

300

2,400

2,572

6,614

450 450

JAMES HARDIEHARDIPLANKSMOOTH 230

SELECTED COLORBONDROOF @ 22.5º PITCH

SELECTED FASCIAAND GUTTER

BARGE & CAPPING

BARGE & CAPPING

FACEBRICK

EAVES EAVES

1:100WEST ELEVATION

873.880873.780

873.680

ALUMINUM FRAMEDWINDOWS AND DOORS

REMOTE CONTROLSECTIONAL DOOR

(PANEL-LIFT)

FLF1

CL

FLF2

CL

FLF3

CL

3493

2636 2293

3493

9c

-12c

0c

25c

17c 10c

876.000

873.000

2,400

300

2,400

2,400

6,634

450450

450

900

JAMES HARDIEHARDIPLANKSMOOTH 230

SELECTED COLORBONDROOF @ 22.5º PITCH

SELECTED FASCIAAND GUTTER

METERBOX

INST.HWS

EAVESEAVES

EAVES

FACEBRICK

FACEBRICK

1:100SOUTH ELEVATION

875.000

874.000

875.6801,3

70

ALUMINUM FRAMEDWINDOWS AND DOORS

PROTECTION OF OPENABLE WINDOWS AS PER B.C.ACONDITION 3.9.2.5A WINDOW OPENING MUST BE PROVIDED WITH PROTECTION IF THE FLOOR BELOWTHE WINDOW IN A BEDROOM IS 2m OR MORE ABOVE THE SURFACE BENEATH.WHERE THE LOWEST LEVEL OF A WINDOW OPENING IS LESS THAN 1.7m ABOVE THEFLOOR, A KEYED LOCK MUST BE FITTED SO AS TO RESTRICT THE WINDOW OPENINGTO A MAX 125mm

PROPOSED NEW RESIDENCE FOR

AT

COPYRIGHT HOTONDO PTY LTDRev Amendment DateA 23/09/21

DATE ........./.........../.................

BUILDER .......................................

DATE ........./.........../.................

CLIENT .......................................

PRELIMINARY DRAWINGS

DrawnVN-EM

THIS DRAWING REMAINS THE PROPERTY OF HOTONDO PTY LTD AND IS PROVIDEDFOR THE USE AS DESCRIBED AND MAY NOT BE USED OR REPRODUCED IN WHOLE

OR IN PART WITHOUT WRITTEN CONSENT

DAWODU & AKINSHOLA

LOT 78 DP 1274510NO. 16 MOUNTAIN VISTAORANGE, NSW 2800

SCALE

DATEDRAWN

DWG No.JOB No.01-2

25/10/21VN-GB

SHEET SIZE A31:800

000224

PRELIMINARY

MODIFIED KALARA 253BASIX CERT. No.

PLAN

TITLE

FACADE

TRADITIONALB 07/10/21WORKING DRAWINGS VN-EMC 13/10/21VO1 VN-GB

SHADOW DIAGRAM

8 7 2 .6 38 7 2 .8 3

8 7 3 .1 08 7 3 .3 8

8 7 3 .6 5

8 7 2 .3 48 7 2 .4 8

8 7 2 .8 1

8 7 3 .6 8

8 7 4 .5 8

8 7 5 .5 2

8 7 6 .4 9

8 7 7 .4 8

8 7 8 .4 5

8 7 9 .3 6

8 8 0 .2 4

8 8 0 .7 4

8 8 1 .1 8

8 8 1 .5 9

8 8 1 .9 7

8 8 2 .1 48 8 2 .2 0

8 8 1 .9 9

8 8 1 .6 9

8 8 1 .3 3

8 8 0 .9 8

8 8 0 .3 0

8 7 9 .6 4

8 7 8 .8 6

8 7 7 .9 1

8 7 7 .0 2

8 7 6 .1 7

8 7 5 .3 2

8 7 4 .4 8

8 7 3 .6 68 7 3 .1 18 7 3 .4 4

8 7 4 .2 1

8 7 4 .8 9

8 7 5 .7 4

8 7 6 .5 4

8 7 7 .3 7

8 7 8 .3 3

8 7 9 .0 3

8 7 9 .8 2

8 8 0 .5 7

8 8 1 .0 9

8 8 1 .4 6

8 8 1 .7 9

8 8 2 .0 98 8 2 .1 8

8 8 1 .8 4

8 8 1 .5 2

8 8 1 .0 5

8 8 0 .4 6

8 7 9 .6 4

8 7 8 .9 6

8 7 8 .1 3

8 7 7 .2 4

8 7 6 .4 1

8 7 5 .5 8

8 7 4 .8 5

8 7 4 .1 8

8 7 3 .6 3

873 .7

8

8 7 4 .3 7

8 7 5 .1 1

8 7 5 .7 7

8 7 6 .6 3

8 7 7 .4 8

8 7 8 .2 6

8 7 9 .0 0

8 7 9 .7 7

8 8 0 .5 5

8 8 1 .1 6

8 8 1 .6 8

8 8 1 .9 3

8 8 2 .2 38 8 2 .1 5

189°

1 3'3 0

"4.5

6 5

R 57

.62A

17.19

C 17

.125 1 8

°06 '2

5 "2 7 9 °1 3 '5 0 "

81.615

189°

16'25

"15

.4 35

9 9 °1 3 '5 0 " 7 8 .9 5

875.

0087

5.00

876.

0087

6.00

877.

0087

7.00

878.

0087

8.00

879.

00

879.

00

880.

00

880.

00

881.00

881.

00

882.

00

882.00

9°4 8

'1 0"

3.08

R L 8 7 2 .6 2

D H & WI N G

B E N C H M A R K

(SM

) - P

ROPO

SED

EASE

MEN

T TO

D

RAIN

SEW

AGE

2.5

WID

E

& V

ARIA

BLE

WID

TH

(SM

)

(SM

)

(SM

)(S

M)(S

M)

NOT E

: BO U

NDAR

I ES

A RE

NOT

F ENC

ED U

N LE S

SS H

OWN

O TH E

RWI S

E

NOT E

: BO U

NDAR

I ES

S HOW

NHE

REON

ARE

PRO

V IS I

O NA L

ONL Y

A ND

S UB J

ECT

TO I N

VEST

IGAT

ION A

NDRE

G IS T

RAT I

ON B

Y T H

EL A

ND R

EGI S

TRY

S ERV

I CES

MET

ALFE

NCE

VACA

NT

VACA

NTVA

CANT

VACA

NT2

1 61 6

mVA

CANT

UN

REG

ISTE

RED

P

LAN

79

7677

7880

DP

125

931826

2757

56

VIST

AM

OUN

TAIN

CONC

RETE

DRIV

EWAY

CONC

RETE

DRIV

EWAY

NBN

PIT

ELEC

TRIC

ITY

PILL

AR

SEW

ER M

ANHO

LEW

ATER

SUP

PLY

SEW

ER JU

NCTI

ON

SEW

ER M

ANHO

LESE

WER

JUNC

TIO

N

STRE

ET L

IGHT

WAT

ER S

UPPL

Y

UPRI

GHT

150

mm

CO

NCRE

TEKE

RB &

GUT

TER

KERB

INLE

T PI

T

DATE

OF S

URVE

Y 21/0

4/21

IN R

EPLY

PLE

ASE

QU

OTE

:

3522

1

8 7 2 .6 38 7 2 .8 3

8 7 3 .1 08 7 3 .3 8

8 7 3 .6 5

8 7 2 .3 48 7 2 .4 8

8 7 2 .8 1

8 7 3 .6 8

8 7 4 .5 8

8 7 5 .5 2

8 7 6 .4 9

8 7 7 .4 8

8 7 8 .4 5

8 7 9 .3 6

8 8 0 .2 4

8 8 0 .7 4

8 8 1 .1 8

8 8 1 .5 9

8 8 1 .9 7

8 8 2 .1 48 8 2 .2 0

8 8 1 .9 9

8 8 1 .6 9

8 8 1 .3 3

8 8 0 .9 8

8 8 0 .3 0

8 7 9 .6 4

8 7 8 .8 6

8 7 7 .9 1

8 7 7 .0 2

8 7 6 .1 7

8 7 5 .3 2

8 7 4 .4 8

8 7 3 .6 68 7 3 .1 18 7 3 .4 4

8 7 4 .2 1

8 7 4 .8 9

8 7 5 .7 4

8 7 6 .5 4

8 7 7 .3 7

8 7 8 .3 3

8 7 9 .0 3

8 7 9 .8 2

8 8 0 .5 7

8 8 1 .0 9

8 8 1 .4 6

8 8 1 .7 9

8 8 2 .0 98 8 2 .1 8

8 8 1 .8 4

8 8 1 .5 2

8 8 1 .0 5

8 8 0 .4 6

8 7 9 .6 4

8 7 8 .9 6

8 7 8 .1 3

8 7 7 .2 4

8 7 6 .4 1

8 7 5 .5 8

8 7 4 .8 5

8 7 4 .1 8

8 7 3 .6 3

873 .7

8

8 7 4 .3 7

8 7 5 .1 1

8 7 5 .7 7

8 7 6 .6 3

8 7 7 .4 8

8 7 8 .2 6

8 7 9 .0 0

8 7 9 .7 7

8 8 0 .5 5

8 8 1 .1 6

8 8 1 .6 8

8 8 1 .9 3

8 8 2 .2 38 8 2 .1 5

1 89°

1 3'3 0

"4.5

6 5

R 57

.62A

17.19

C 17

.125 1 8

°06 '2

5 "

2 7 9 °1 3 '5 0 "81.615

189°

16'25

"15

.4 35

9 9 °1 3 '5 0 " 7 8 .9 5

875.

0087

5.00

876.

0087

6.00

877.

0087

7.00

878.

0087

8.00

879.

00

879.

00

880.

00

880.

00

881.00

881.

00

882.

00

882.00

9°4 8

'1 0"

3.08

R L 8 7 2 .6 2

D H & WI N G

B E N C H M A R K

(SM

) - P

ROPO

SED

EASE

MEN

T TO

D

RAIN

SEW

AGE

2.5

WID

E

& V

ARIA

BLE

WID

TH

(SM

)

(SM

)

(SM

)(S

M)(S

M)

NOT E

: BOU

NDAR

I ES

A RE

NOT

F ENC

ED U

N LE S

SS H

OWN

O TH E

RWI S

E

NOT E

: BO U

NDAR

I ES

S HOW

NHE

REON

ARE

PRO

V IS I

ONA L

ONLY

A ND

SUB J

ECT

TO I N

V ES T

I GA T

I ON A

NDRE

G IS T

RAT I

ON B

Y TH

ELA

ND R

EGI S

TRY

S ERV

I CE S

MET

ALFE

NCE

VACA

NT

VACA

NTVA

CANT

VACA

NT2

1 61 6

mVA

CANT

UN

REG

ISTE

RED

P

LAN

79

7677

7880

DP

125

931826

2757

56

VIST

AM

OUN

TAIN

CONC

RETE

DRIV

EWAY

CONC

RETE

DRIV

EWAY

NBN

PIT

ELEC

TRIC

ITY

PILL

AR

SEW

ER M

ANHO

LEW

ATER

SUP

PLY

SEW

ER JU

NCTI

ON

SEW

ER M

ANHO

LESE

WER

JUNC

TIO

N

STRE

ET L

IGHT

WAT

ER S

UPPL

Y

UPRI

GHT

150

mm

CO

NCRE

TEKE

RB &

GUT

TER

KERB

INLE

T PI

T

DATE

OF S

URVE

Y 21/0

4/21

IN R

EPLY

PLE

ASE

QU

OTE

:

3522

1

8 7 2 .6 38 7 2 .8 3

8 7 3 .1 08 7 3 .3 8

8 7 3 .6 5

8 7 2 .3 48 7 2 .4 8

8 7 2 .8 1

8 7 3 .6 8

8 7 4 .5 8

8 7 5 .5 2

8 7 6 .4 9

8 7 7 .4 8

8 7 8 .4 5

8 7 9 .3 6

8 8 0 .2 4

8 8 0 .7 4

8 8 1 .1 8

8 8 1 .5 9

8 8 1 .9 7

8 8 2 .1 48 8 2 .2 0

8 8 1 .9 9

8 8 1 .6 9

8 8 1 .3 3

8 8 0 .9 8

8 8 0 .3 0

8 7 9 .6 4

8 7 8 .8 6

8 7 7 .9 1

8 7 7 .0 2

8 7 6 .1 7

8 7 5 .3 2

8 7 4 .4 8

8 7 3 .6 68 7 3 .1 18 7 3 .4 4

8 7 4 .2 1

8 7 4 .8 9

8 7 5 .7 4

8 7 6 .5 4

8 7 7 .3 7

8 7 8 .3 3

8 7 9 .0 3

8 7 9 .8 2

8 8 0 .5 7

8 8 1 .0 9

8 8 1 .4 6

8 8 1 .7 9

8 8 2 .0 98 8 2 .1 8

8 8 1 .8 4

8 8 1 .5 2

8 8 1 .0 5

8 8 0 .4 6

8 7 9 .6 4

8 7 8 .9 6

8 7 8 .1 3

8 7 7 .2 4

8 7 6 .4 1

8 7 5 .5 8

8 7 4 .8 5

8 7 4 .1 8

8 7 3 .6 3

873 .7

8

8 7 4 .3 7

8 7 5 .1 1

8 7 5 .7 7

8 7 6 .6 3

8 7 7 .4 8

8 7 8 .2 6

8 7 9 .0 0

8 7 9 .7 7

8 8 0 .5 5

8 8 1 .1 6

8 8 1 .6 8

8 8 1 .9 3

8 8 2 .2 38 8 2 .1 5

189°

1 3'3 0

"4.5

6 5

R 57

.62A

17.19

C 17

.125 1 8

°06 '2

5 "

2 7 9 °1 3 '5 0 "81.615

189°

16'25

"15

.4 35

9 9 °1 3 '5 0 " 7 8 .9 5

875.

0087

5.00

876.

0087

6.00

877.

0087

7.00

878.

0087

8.00

879.

00

879.

00

880.

00

880.

00

881.00

881.

00

882.

00

882.00

9°4 8

'1 0"

3.08

R L 8 7 2 .6 2

D H & WI N G

B E N C H M A R K

(SM

) - P

ROPO

SED

EASE

MEN

T TO

D

RAIN

SEW

AGE

2.5

WID

E

& V

ARIA

BLE

WID

TH

(SM

)

(SM

)

(SM

)(S

M)(S

M)

NOT E

: BOU

NDAR

I ES

A RE

NOT

F ENC

ED U

N LE S

SS H

OWN

O TH E

RWI S

E

NOT E

: BO U

NDAR

I ES

S HOW

NHE

REON

ARE

PRO

V IS I

ONA L

ONL Y

AND

SUB J

ECT

TO I N

VEST

IGAT

ION A

NDRE

G IS T

RAT I

ON B

Y TH

ELA

ND R

EGI S

TRY

S ERV

I CES

MET

ALFE

NCE

VACA

NT

VACA

NTVA

CANT

VACA

NT2

1 61 6

mVA

CANT

UN

REG

ISTE

RED

P

LAN

79

7677

7880

DP

125

931826

2757

56

VIST

AM

OUN

TAIN

CONC

RETE

DRIV

EWAY

CONC

RETE

DRIV

EWAY

NBN

PIT

ELEC

TRIC

ITY

PILL

AR

SEW

ER M

ANHO

LEW

ATER

SUP

PLY

SEW

ER JU

NCTI

ON

SEW

ER M

ANHO

LESE

WER

JUNC

TIO

N

STRE

ET L

IGHT

WAT

ER S

UPPL

Y

UPRI

GHT

150

mm

CO

NCRE

TEKE

RB &

GUT

TER

KERB

INLE

T PI

T

DATE

OF S

URVE

Y 21/0

4/21

IN R

EPLY

PLE

ASE

QU

OTE

:

3522

1

SCALE 1:800

SHADOW DIAGRAMJUNE 21 - 9AM

SCALE 1:800

SHADOW DIAGRAMJUNE 21 - 12NN

N N

SCALE 1:800

SHADOW DIAGRAMJUNE 21 - 3PM

N