  • PRE-FINISHED WOOD SIDING ON 1" STRAPPING ON TYVEK MOISTURE BARRIER ON 1

    2 " OSB SHEATHING TO WOOD STUD WALL w/ R24 BATT INSULATION 6mm POLY. VAPOR BARRIER 1

    2 " DRYWALL w/ TAPED JOINTS PAINTED FINISH INTERNALLY

    6" ALUMINIUM FASCIA TO 2"x 6" WOOD FASCIA BOARD

    VENTED ALUMINIUM SOFFIT

    6" PREFINISHED WOOD TRIM BELOW EAVES

    ICE & WATER SHIELD MEMBRANE EXTENDS FROM EAVES TO MIN 3' INSIDE LINE OF EXTERNAL WALL

    #235 ASPHALT SHINGLE ROOF ON 1

    2" PLYWOOD SHEATHING w/ H-CLIPS ON PRE-FABRICATED WOOD TRUSS

    OPAQUE WINDOW

    FIRST FLOOR LVL + 98 . 630

    ESTABLISHED GRADE + 97 . 900

    SECOND FLOOR LVL + 101 . 630

    BASEMENT LVL + 95 . 650

    RIDGE LVL (MAX) + 106 . 920

    CEILING LVL (TYP) + 104 . 070

    GENERAL NOTES

    FEATURES OF CONSTRUCTION NOT FULLY SHOWN ARE TO BE THE SAME CHARACTER AS THOSE NOTED FOR SIMILAR CONDITIONS.

    ALL DIMENSIONS AND INFORMATION SHOWN ON THESE DRAWINGS MUST BE CHECKED AND VERIFIED ON SITE PRIOR TO CONSTRUCTION AND FABRICATION OF ITS COMPONENTS. SHOULD EXISTING CONDITIONS OR SERVICES BE FOUND TO VARY FROM THOSE INDICATED ON THE ARCHITECTURAL DRAWINGS, THE DESIGN OFFICE MUST BE NOTIFIED IMMEDIATELY.

    UNLESS SPECIFICALLY NOTED OTHERWISE ON THE DRAWINGS, NO PROVISION HAS BEEN MADE ON THE DRAWINGS FOR CONDITIONS OCCURRING DURING CONSTRUCTION. THE CONTRACTOR IS TO PROVIDE ALL NECESSARY BRACING AND SHORING REQUIRED FOR STRESS AND INSTABILITY OCCURRING FROM ANY CAUSE DURING CONSTRUCTION. THE CONTRACTOR SHALL ACCEPT RESPONSIBILITY FOR ALL SUCH MEASURES. IT SHALL ALSO BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE ALL NECESSARY BRACING, SHORING, SHEET PILING OR OTHER TEMPORARY SUPPORTS TO SAFEGUARD ALL EXISTING OR ADJACENT STRUCTURES AFFECTED BY THIS WORK.

    DO NOT SCALE DRAWINGS.

    THE UNDERSIGNED HAS REVIEWED & TAKES RESPONSIBILITY FOR THIS DESIGN, HAS THE QUALIFICATIONS & MEETS THE REQUIREMENTS SET OUT IN THE ONTARIO BUILDING CODE TO BE A DESIGNER.

    QUALIFICATION INFORMATION REQUIRED UNLESS DESIGN IS EXEMPT UNDER 2.17.5.1 OF THE BUILDING CODE.

    Jonathan Sprawson 32490 _______________________________________________________

    NAME SIGNATURE BCIN

    REGISTRATION INFORMATION REQUIRED UNLESS DESIGN IS EXEMPT UNDER 2.17.4.1 OF THE BUILDING CODE.

    Design Quorum Inc. 35234 _______________________________________________________

    FIRM NAME BCIN

    REV NO. DESCRIPTION DATE BY

    DRAWING NO. REV

    DRAWN BY CHECKED BY CLIENT APPROVAL

    DRAWING TITLE

    DATE SCALE

    STATUS

    PROJECT TITLE

    CLIENT

    PROPOSED ELEVATIONS

    SB

    A - 203

    AS NOTED

    SB

    REAR (EAST) ELEVATION A-203

    1

    INGLEHART RESIDENCE 407 INGLEHART ST S, OAKVILLE, ONTARIO

    SPRAWSON REALTY LTD.

    JS INCORPORATED

    SB- '16.09.30COMMITTEE OF ADJUSTMENT APPLICATION

    SITE PLAN APPROVAL

    '16.11.23 SBA PRE-CONSULTATION MEETING REQUEST

    '17.05.25 SBB REVISIONS FOLLOWING PRE-CONSULTATIONMEETING 2017.01.25

    PROPOSED - No. 407

    © 24 JULY 2017

    C

    '17.07.24 SBC SITE PLAN APPROVAL APPLICATION

    AutoCAD SHX Text 0

    AutoCAD SHX Text 1

    AutoCAD SHX Text 2

    AutoCAD SHX Text SCALE 1 : 100

    AutoCAD SHX Text 4

    AutoCAD SHX Text 3

    AutoCAD SHX Text 5

    AutoCAD SHX Text 6

    AutoCAD SHX Text 7

    AutoCAD SHX Text METERS

    AutoCAD SHX Text 8

    AutoCAD SHX Text 9

    AutoCAD SHX Text 10

  • FIRST FLOOR LVL + 98 . 630

    ESTABLISHED GRADE + 97 . 900

    SECOND FLOOR LVL + 101 . 630

    BASEMENT LVL + 95 . 650

    RIDGE LVL (MAX) + 106 . 920

    CEILING LVL (TYP) + 104 . 070

    CA B

    ESTABLISHED GRADE + 97 . 900

    RIDGE LEVEL + 101 . 900

    EAVES LEVEL + 100 . 380

    RIDGE LEVEL + 101 . 540

    ICE & WATER SHIELD MEMBRANE EXTENDS FROM EAVES TO MIN 3' INSIDE LINE OF EXTERNAL WALL

    6" ALUMINIUM FASCIA TO 2"x 6" WOOD FASCIA BOARD

    VENTED ALUMINIUM SOFFIT

    6" PREFINISHED WOOD TRIM BELOW EAVES

    #235 ASPHALT SHINGLE ROOF ON 1

    2" PLYWOOD SHEATHING w/ H-CLIPS ON PRE-FABRICATED WOOD TRUSS

    6" PREFINISHED WOOD TRIM

    ICE & WATER SHIELD MEMBRANE EXTENDS FROM EAVES TO MIN 3' INSIDE LINE OF EXTERNAL WALL

    PRE-FINISHED WOOD SIDING ON 1" STRAPPING ON TYVEK MOISTURE BARRIER ON 1

    2 " OSB SHEATHING TO WOOD STUD WALL w/ R24 BATT INSULATION 6mm POLY. VAPOR BARRIER 1

    2 " DRYWALL w/ TAPED JOINTS , PAINTED FINISH INTERNALLY

    #235 ASPHALT SHINGLE ROOF ON 1

    2" PLYWOOD SHEATHING w/ H-CLIPS ON PRE-FABRICATED WOOD TRUSS

    GENERAL NOTES

    FEATURES OF CONSTRUCTION NOT FULLY SHOWN ARE TO BE THE SAME CHARACTER AS THOSE NOTED FOR SIMILAR CONDITIONS.

    ALL DIMENSIONS AND INFORMATION SHOWN ON THESE DRAWINGS MUST BE CHECKED AND VERIFIED ON SITE PRIOR TO CONSTRUCTION AND FABRICATION OF ITS COMPONENTS. SHOULD EXISTING CONDITIONS OR SERVICES BE FOUND TO VARY FROM THOSE INDICATED ON THE ARCHITECTURAL DRAWINGS, THE DESIGN OFFICE MUST BE NOTIFIED IMMEDIATELY.

    UNLESS SPECIFICALLY NOTED OTHERWISE ON THE DRAWINGS, NO PROVISION HAS BEEN MADE ON THE DRAWINGS FOR CONDITIONS OCCURRING DURING CONSTRUCTION. THE CONTRACTOR IS TO PROVIDE ALL NECESSARY BRACING AND SHORING REQUIRED FOR STRESS AND INSTABILITY OCCURRING FROM ANY CAUSE DURING CONSTRUCTION. THE CONTRACTOR SHALL ACCEPT RESPONSIBILITY FOR ALL SUCH MEASURES. IT SHALL ALSO BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE ALL NECESSARY BRACING, SHORING, SHEET PILING OR OTHER TEMPORARY SUPPORTS TO SAFEGUARD ALL EXISTING OR ADJACENT STRUCTURES AFFECTED BY THIS WORK.

    DO NOT SCALE DRAWINGS.

    THE UNDERSIGNED HAS REVIEWED & TAKES RESPONSIBILITY FOR THIS DESIGN, HAS THE QUALIFICATIONS & MEETS THE REQUIREMENTS SET OUT IN THE ONTARIO BUILDING CODE TO BE A DESIGNER.

    QUALIFICATION INFORMATION REQUIRED UNLESS DESIGN IS EXEMPT UNDER 2.17.5.1 OF THE BUILDING CODE.

    Jonathan Sprawson 32490 _______________________________________________________

    NAME SIGNATURE BCIN

    REGISTRATION INFORMATION REQUIRED UNLESS DESIGN IS EXEMPT UNDER 2.17.4.1 OF THE BUILDING CODE.

    Design Quorum Inc. 35234 _______________________________________________________

    FIRM NAME BCIN

    REV NO. DESCRIPTION DATE BY

    DRAWING NO. REV

    DRAWN BY CHECKED BY CLIENT APPROVAL

    DRAWING TITLE

    DATE SCALE

    STATUS

    PROJECT TITLE

    CLIENT

    PROPOSED ELEVATIONS

    SB

    A - 204

    AS NOTED

    SB

    SIDE (NORTH) ELEVATION A-204

    1 INGLEHART RESIDENCE

    407 INGLEHART ST S, OAKVILLE, ONTARIO

    SPRAWSON REALTY LTD.

    JS INCORPORATED

    SB-

    PROPOSED - No. 407

    '16.09.30COMMITTEE OF ADJUSTMENT APPLICATION

    SITE PLAN APPROVAL

    '16.11.23 SBA PRE-CONSULTATION MEETING REQUEST

    '17.05.25 SBB REVISIONS FOLLOWING PRE-CONSULTATIONMEETING 2017.01.25

    '17.06.13 SBC GARAGE HEIGHT ADJUSTED

    © 24 JULY 2017

    C

    '17.07.24 SBD SITE PLAN APPROVAL APPLICATION

    AutoCAD SHX Text 0

    AutoCAD SHX Text 1

    AutoCAD SHX Text 2

    AutoCAD SHX Text SCALE 1 : 100

    AutoCAD SHX Text 4

    AutoCAD SHX Text 3

    AutoCAD SHX Text 5

    AutoCAD SHX Text 6

    AutoCAD SHX Text 7

    AutoCAD SHX Text METERS

    AutoCAD SHX Text 8

    AutoCAD SHX Text 9

    AutoCAD SHX Text 10

  • FIRST FLOOR LVL + 98 . 630

    ESTABLISHED GRADE + 97 . 900

    SECOND FLOOR LVL + 101 . 630

    BASEMENT LVL + 95 . 650

    RIDGE LVL (MAX) + 106 . 920

    CEILING LVL (TYP) + 104 . 070

    C AB

    UNPROTECTED OPENINGS CALCULATION AS PER O.B.C. 2012; 9.10.14

    WALL AREA: 87.15 sq m = 938.08 sq ft LIMITING DISTANCE: 1. 20 m (1. 20 m ACTUAL DISTANCE)

    MAX. ALLOWABLE OPENINGS: 7. 0% = 6. 10 sq m = 65.65 sq ft TOTAL OPENINGS PROVIDED: 3. 60% = 3. 145sq m = 33.85 sq ft

    ESTABLISHED GRADE + 97 . 900

    RIDGE LEVEL + 101 . 900

    EAVES LEVEL + 100 . 380

    RIDGE LEVEL + 101 . 540

    ICE & WATER SHIELD MEMBRANE EXTENDS FROM EAVES TO MIN 3' INSIDE LINE OF EXTERNAL WALL

    6" ALUMINIUM FASCIA TO 2"x 6" WOOD FASCIA BOARD

    VENTED ALUMINIUM SOFFIT

    6" PREFINISHED WOOD TRIM BELOW EAVES

    #235 ASPHALT SHINGLE ROOF ON 1

    2" PLYWOOD SHEATHING w/ H-CLIPS ON PRE-FABRICATED WOOD TRUSS

    6" PREFINISHED WOOD TRIM

    ICE & WATER SHIELD MEMBRANE EXTENDS FROM EAVES TO MIN 3' INSIDE LINE OF EXTERNAL WALL

    PRE-FINISHED WOOD SIDING ON 1" STRAPPING ON TYVEK MOISTURE BARRIER ON 1

    2 " OSB SHEATHING TO WOOD STUD WALL w/ R24 BATT INSULATION 6mm POLY. VAPOR BARRIER 1

    2 " DRYWALL w/ TAPED JOINTS , PAINTED FINISH INTERNALLY

    #235 ASPHALT SHINGLE ROOF ON 1

    2" PLYWOOD SHEATHING w/ H-CLIPS ON PRE-FABRICATED WOOD TRUSS

    ESTABLISHED GRADE + 97 . 900

    RIDGE LEVEL + 101 . 900

    EAVES LEVEL + 100 . 380

    RIDGE LEVEL + 101 . 540

    ESTABLISHED GRADE + 97 . 900

    RIDGE LEVEL + 101 . 900

    EAVES LEVEL + 100 . 380

    RIDGE LEVEL + 101 . 540

    GENERAL NOTES

    FEATURES OF CONSTRUCTION NOT FULLY SHOWN ARE TO BE THE SAME CHARACTER AS THOSE NOTED FOR SIMILAR CONDITIONS.

    ALL DIMENSIONS AND INFORMATION SHOWN ON THESE DRAWINGS M