North Elevation - Oakville planning/sp-17290410201-elevat… · msai C7009 Jan. 2017 Proposed...

2
Retail Sign Retail Sign Retail Sign Retail Sign Retail Sign Retail Sign Ground Floor Second Floor Third Floor Fourth Floor P1 5400 3200 3200 1 2 3 4 5 6 7 8 9 H G F E D C B A Ground Floor Second Floor Third Floor Fourth Floor P1 5400 3200 3200 Roof 3200 15000 Roof 3200 15000 North Elevation East Elevation MASONRY FEATURES DESCRIPTION GRAY STONE VENEER (ROUGH) LIGHT GRAY STONE VENEER (SMOOTH) REDDISH BROWN BRICK VENEER WHITE COMPOSITE BOARD TRIM COMPOSITE BOARD SIDING ALUMINUM STOREFRONT WINDOW ALUMINUM STOREFRONT DOOR TRADITIONAL WINDOW TRADITIONAL DOOR ALUMINUM RAIL WITH GLASS GOOSE NECK LIGHT SCONCE LIGHT FABRIC CANOPY WHITE COMPOSITE CORNICE STANDING SEEM METAL ROOFING INSULATED OVERHEAD DOOR ** 'SP' DENOTES SPANDREL WINDOW 4 3 6 7 2 1 8 5 11 2 8 7 3 9 10 11 12 13 14 15 16 16 15 14 13 12 2 1 10 9 4 5 15 SP SP SP SP SP SP SP SP SP SP SP SP SP SP SP SP SP SP All New Mech Units to be Less than 2m in height. All New Units to be Screened as Outlined in Zoning By-Law with Prefinished Metal Screens. Screen Colour to Match Cap Flashing. Parapets Height Approx 450mm (not to exceed 2m) Mech Penthouse Beyond Mech Penthouse Beyond 2 1 4 3 10 9 14 8 Limiting Distance: 3.8m Permitted %: 28.4% EBF: 301 sm Permitted Area of UO: 85.5sm Proposed Area of UO:` 85.5sm Proposed % of UO: 28.4% Limiting Distance: 2.8m Permitted %: 21.2% EBF: 80 sm Permitted Area of UO: 16.96 sm Proposed Area of UO:` 16.5sm Proposed % of UO: 20.6% 1:250 A201 FILE NO. SHEET NO: DATE: SHEET TITLE: CHECKED: PROJECT NO. DRAWN: SCALE: PROJECT: CLIENT: Succession Development Corporation Oakville, Ontario C7009 _____ msai C7009 Jan. 2017 Proposed Retirement Residence 2380 Lakeshore Road West Oakville, Ont. Proposed Elevations

Transcript of North Elevation - Oakville planning/sp-17290410201-elevat… · msai C7009 Jan. 2017 Proposed...

Page 1: North Elevation - Oakville planning/sp-17290410201-elevat… · msai C7009 Jan. 2017 Proposed Retirement Residence 2380 Lakeshore Road West Oakville, Ont. Proposed Elevations. ISSUED:

Retail Sign Retail Sign Retail Sign Retail SignRetail SignRetail Sign

Ground Floor

Second Floor

Third Floor

Fourth Floor

P1

54

00

32

00

32

00

123456789

HGFEDCBA

Ground Floor

Second Floor

Third Floor

Fourth Floor

P1

54

00

32

00

32

00

Roof

32

00

15

00

0

Roof

32

00

15

00

0

North Elevation

East Elevation

MASONRY FEATURESDESCRIPTION

GRAY STONE VENEER (ROUGH)

LIGHT GRAY STONE VENEER (SMOOTH)

REDDISH BROWN BRICK VENEER

WHITE COMPOSITE BOARD TRIM

COMPOSITE BOARD SIDING

ALUMINUM STOREFRONT WINDOW

ALUMINUM STOREFRONT DOOR

TRADITIONAL WINDOW

TRADITIONAL DOOR

ALUMINUM RAIL WITH GLASS

GOOSE NECK LIGHT

SCONCE LIGHT

FABRIC CANOPY

WHITE COMPOSITE CORNICE

STANDING SEEM METAL ROOFING

INSULATED OVERHEAD DOOR

** 'SP' DENOTES SPANDREL WINDOW

4

3

6

7

2

1

8

5

11

2

8

7

3

9

10

11

12

13

14

15

16

16

15

14

13

12

2

1

10

9

4

5

15

SP SP SP SP SP SP

SP SP SP SP SP SP

SP SP SP SP SP SP

All New Mech Units to be Less than 2m in height. All New Units to

be Screened as Outlined in Zoning By-Law with Prefinished Metal

Screens. Screen Colour to Match Cap Flashing.

Parapets Height Approx 450mm (not to exceed 2m)

Mech Penthouse Beyond

Mech Penthouse Beyond

2

1

4

3

10

9

14

8

Limiting Distance: 3.8m

Permitted %: 28.4%

EBF: 301 sm

Permitted Area of UO: 85.5sm

Proposed Area of UO:` 85.5sm

Proposed % of UO: 28.4%

Limiting Distance: 2.8m

Permitted %: 21.2%

EBF: 80 sm

Permitted Area of UO: 16.96 sm

Proposed Area of UO:` 16.5sm

Proposed % of UO: 20.6%

1:250

A201

FILE NO.

SHEET NO:

DATE:

SHEET TITLE:

CHECKED:

PROJECT NO.

DRAWN:

SCALE:

PROJECT:

CLIENT:

Succession

Development

Corporation

Oakville, Ontario

C7009

_____

msai

C7009

Jan. 2017

Proposed

Retirement Residence

2380 Lakeshore Road West

Oakville, Ont.

Proposed

Elevations

AutoCAD SHX Text
ISSUED:
AutoCAD SHX Text
REVISIONS:
AutoCAD SHX Text
This drawing is the property of the Architect
AutoCAD SHX Text
and may not be reproduced or used without the
AutoCAD SHX Text
project and to report any discrepancies to the
AutoCAD SHX Text
Architect prior to commencing work. These drawings
AutoCAD SHX Text
are not to be used for construction purposes unless
AutoCAD SHX Text
indicated as "issued for construction".
AutoCAD SHX Text
is to verify all dimensions and conditions on the
AutoCAD SHX Text
expressed consent of the Architect. The contractor
AutoCAD SHX Text
NO:
AutoCAD SHX Text
NOTE:
AutoCAD SHX Text
1
AutoCAD SHX Text
Issued for Submission
AutoCAD SHX Text
July 5, '18
AutoCAD SHX Text
2
AutoCAD SHX Text
3
Page 2: North Elevation - Oakville planning/sp-17290410201-elevat… · msai C7009 Jan. 2017 Proposed Retirement Residence 2380 Lakeshore Road West Oakville, Ont. Proposed Elevations. ISSUED:

Ground Floor

Second Floor

Third Floor

Fourth Floor

P1

54

00

32

00

32

00

H G F E D C B A

Ground Floor

Second Floor

Third Floor

Fourth Floor

P1

54

00

32

00

32

00

2a 3a 4a 4b 5a 6a 7a

15

00

0

Roof

32

00

15

00

0

Roof

32

00

South Elevation

West Elevation

15

14

4

6

5

3

2

1

6

10

15

14

4

10

3

8

1

2

6

SP SPSP SP SPSP

SP SP SP SP SP SP

SP SP SP SP SP SP

SP SP SP SP SP SP

MASONRY FEATURESDESCRIPTION

GRAY STONE VENEER (ROUGH)

LIGHT GRAY STONE VENEER (SMOOTH)

REDDISH BROWN BRICK VENEER

WHITE COMPOSITE BOARD TRIM

COMPOSITE BOARD SIDING

ALUMINUM STOREFRONT WINDOW

ALUMINUM STOREFRONT DOOR

TRADITIONAL WINDOW

TRADITIONAL DOOR

ALUMINUM RAIL WITH GLASS

GOOSE NECK LIGHT

SCONCE LIGHT

FABRIC CANOPY

WHITE COMPOSITE CORNICE

STANDING SEEM METAL ROOFING

INSULATED OVERHEAD DOOR

** 'SP' DENOTES SPANDREL WINDOW

4

3

6

7

2

1

8

5

9

10

11

12

13

14

15

16

All New Mech Units to be Less than 2m in height. All New Units to

be Screened as Outlined in Zoning By-Law with Prefinished Metal

Screens. Screen Colour to Match Cap Flashing.

Parapets Height Approx 450mm (not to exceed 2m)

Mech Penthouse Beyond

Mech Penthouse Beyond

Limiting Distance: 5.7m

Permitted %: 40.0%

EBF: 486 sm

Permitted Area of UO: 194.4sm

Proposed Area of UO:` 172.5sm

Proposed % of UO: 35.3%

Limiting Distance: 4.9m

Permitted %: 39.0%

EBF: 137 sm

Permitted Area of UO: 53.4sm

Proposed Area of UO:` 46.5sm

Proposed % of UO: 34%

Limiting Distance: 4.0m

Permitted %: 30%

EBF: 317 sm

Permitted Area of UO: 95 sm

Proposed Area of UO:` 93 sm

Proposed % of UO: 29%

Limiting Distance: 5.5m

Permitted %: 40%

EBF: 460 sm

Permitted Area of UO: 184 sm

Proposed Area of UO:` 157.6 sm

Proposed % of UO: 34.2%

1:250

A202

FILE NO.

SHEET NO:

DATE:

SHEET TITLE:

CHECKED:

PROJECT NO.

DRAWN:

SCALE:

PROJECT:

CLIENT:

Succession

Development

Corporation

Oakville, Ontario

C7009

_____

msai

C7009

Jan. 2017

Proposed

Retirement Residence

2380 Lakeshore Road West

Oakville, Ont.

Proposed

Elevations

AutoCAD SHX Text
ISSUED:
AutoCAD SHX Text
REVISIONS:
AutoCAD SHX Text
This drawing is the property of the Architect
AutoCAD SHX Text
and may not be reproduced or used without the
AutoCAD SHX Text
project and to report any discrepancies to the
AutoCAD SHX Text
Architect prior to commencing work. These drawings
AutoCAD SHX Text
are not to be used for construction purposes unless
AutoCAD SHX Text
indicated as "issued for construction".
AutoCAD SHX Text
is to verify all dimensions and conditions on the
AutoCAD SHX Text
expressed consent of the Architect. The contractor
AutoCAD SHX Text
NO:
AutoCAD SHX Text
NOTE:
AutoCAD SHX Text
1
AutoCAD SHX Text
Issued for Submission
AutoCAD SHX Text
July 5, '18
AutoCAD SHX Text
2
AutoCAD SHX Text
3