hahsahsahsy

22
DEPARTEMEN TEKNIK KIMIA UNIVERSITAS INDONESIA 1 Termodinamika BAB I JAWABAN PEMICU 3 1. Assignment 1 (10) The Ranque-Hilsch vortex tube is a device that receives a gas stream (say at 10 bar and 295 K) and divides it into two streams with equal mass flow rates and equal pressures (say 1 bar). There is no mechanical work and heat transfer involve in the operation of this device. Show by using the first and the second law of thermodynamics, that maximum temperature difference between the outlet streams is 501 K. Hint: largest temperature difference can be obtained only if gas expansion is a reversible process. Use Cp gas of kJ/(kmol.K). JAWAB Diketahui : Ti = 295 K pi = 10 bar pc = ph = 1 bar cp = 30 kJ/kmol.K Tidak ada kerja mekanik (W= 0) dan perpindahan panas pada pengoperasiannya (Q=0) Laju alir panas dan dingin sama ( h = c) Proses reversibel Ditanya : Buktikan perbedaan suhu antara outlet stream adalah 501 K dengan menggunakan hukum pertama dan kedua termodinamika? Penyelesaian : Gambar 1. Ranque-Hilsch vortex tube

description

hsjahsjah

Transcript of hahsahsahsy

  • DEPARTEMEN TEKNIK KIMIA UNIVERSITAS INDONESIA 1

    Termodinamika

    BAB I

    JAWABAN PEMICU 3

    1. Assignment 1 (10)

    The Ranque-Hilsch vortex tube is a device that receives a gas stream (say at 10 bar and

    295 K) and divides it into two streams with equal mass flow rates and equal pressures (say 1

    bar). There is no mechanical work and heat transfer involve in the operation of this device.

    Show by using the first and the second law of thermodynamics, that maximum temperature

    difference between the outlet streams is 501 K. Hint: largest temperature difference can be

    obtained only if gas expansion is a reversible process. Use Cp gas of kJ/(kmol.K).

    JAWAB

    Diketahui :

    Ti = 295 K

    pi = 10 bar

    pc = ph = 1 bar

    cp = 30 kJ/kmol.K

    Tidak ada kerja mekanik (W= 0) dan perpindahan panas pada pengoperasiannya (Q=0)

    Laju alir panas dan dingin sama (h = c)

    Proses reversibel

    Ditanya :

    Buktikan perbedaan suhu antara outlet stream adalah 501 K dengan menggunakan

    hukum pertama dan kedua termodinamika?

    Penyelesaian :

    Gambar 1. Ranque-Hilsch vortex tube

  • DEPARTEMEN TEKNIK KIMIA UNIVERSITAS INDONESIA 2

    Termodinamika

    Berdasarkan hukum termodinamika I :

    + + =

    karena diasumsikan tidak ada perpindahan panas dan tidak terdapat kerja mekanik, maka :

    = 0

    = + = 0

    = ( ) + ( ) = 0

    Kemudian persamaan diatas dapat disederhanakan dengan = h + c,dan didapatkan

    = (1

    ) +

    Subskrip i, c, dan h menunjukkan aliran masuk, dingin, dan panas yang ditinjau berdasarkan

    perubahan entropi untuk gas ideal.

    Kemudian, berdasarkan hukum termodinamika II karena prosesnya reversibel, maka dapat

    diasumsikan () = 0

    = 1

    = 0

    = +

    =

    [ ln

    + ln

    ] +

    [ ln

    + ln

    ]

    Sehingga, dari dua penurunan persamaan hukum termodinamika I & II tersebut maka dapat

    dihitung & dibuktikan beda suhu maksimum antara gas panas dan dinginnya.

    +

    = 1

    =

    = 0,5

    = (1

    ) +

    295 = (1 0,5) + 0,5

    590 = +

    = = = +

    590 = ( + ) + = 2 +

    = 590 2

    [ ln

    + ln

    ] +

    [ ln

    + ln

    ] = 0

    [ ln

    + ln

    ] + [ ln

    + ln

    ] = 0

  • DEPARTEMEN TEKNIK KIMIA UNIVERSITAS INDONESIA 3

    Termodinamika

    [30

    28,97ln

    295

    +8,314

    28,97ln

    10

    1] + [

    30

    28,97ln

    295

    +8,314

    28,97ln

    10

    1] = 0

    = 24252

    ( + ) = 24252

    ( + (590 2)) = 24252

    590 2 = 24252

    = , 2 = 545,5

    = = (, ) =

    2. Assignment 2 (35)

    Electrical power is needed to supply electricity for constant lighting and heat for

    maintaining constant temperature environment in the greenhouse for growing a vegetable. Gas

    engines employed to produce the required electrical power are also producing waste heat that

    could be utilized further o generate additional electrical power. The thermal emergy generated

    by the gas engines is more than adequate to heat the greenhouse and utilizatio of the excess

    (waste) heat is desireable. The waste heat is available at around 100C and at this relatively

    low temperature a Rankine cycle with an organic compound as the working fluid known as

    Organic Rankine Cycle (ORC) shown above will be the most suitable option for heat reovery.

    The following picture shows a typical waste heat recovery system.

    The working fluid used ini the ORC is ammonia. Superheated ammonia vapor enters the turbine

    at 95C. Ammonia exits the condensor as saturated liquid at 25C and leaves the pump at 5

    Mpa. Based on the following assumptions:

  • DEPARTEMEN TEKNIK KIMIA UNIVERSITAS INDONESIA 4

    Termodinamika

    Thermal energy in the amount of 1575 kW can be transferred from the gas engine to

    the working fluid

    Water pressure at stream 5 and 6 is 1 bar

    The expander and the pump have adiabatic efficiency of 75%

    Temperature of stream 5 and 6 are 15 and 20C, respectively

    There is no pressure drop in the boiler and in the condensor

    Determine the following:

    a. The electrical output of the expander

    b. As in part a) but use 6 Mpa for the pressure of stream 4

    c. The efficiency of the ORC cycle based on your answer in part a) and b). Why are they

    different

    d. The water mass flow rate circulating between the ORC and the aquifer based on answer

    for part a)

    e. Fill in the following table :

    For P4 = 5 MPa and P4 = 6 MPa

    Stream 1 2 3 4 5 6

    Vapor fraction

    T (C)

    P (bar)

    Mass flow rate (ton/h)

    Dont forget to include your calculation sheet in your report.

    JAWAB

    Penyelesaian:

    Diketahui:

    Superheated vapor

    T1 = 95oC P1 = 5 MPa

    P2 = P3

    P5 = 1 bar

    T5 = 15oC

    P6 = 1 bar

    T6 = 20oC

    P4 = 5 Mpa

    Saturated liquid

    T1 = 25oC

    Qin = 1575 kW

  • DEPARTEMEN TEKNIK KIMIA UNIVERSITAS INDONESIA 5

    Termodinamika

    sistem ORC (Organic Rankine Cycle) dengan fluida kerja amonia

    suhu uap amonia superheated masuk expander (T1) pada 95C

    suhu cairan amonia jenuh keluar kondensor (T3) pada 25C dan meninggalkan pompa

    dengan P4 = 5 MPa

    pompa= expander= 75%

    Qin= 1575 kW

    1 = 2 = 3 = 4 = 7 = 8 = NH3

    5 = 6 = H2O

    Ditanya :

    a. W pada expander (WE)?

    b. W pada expander (WE) jika aliran pompa (4) adalah 6 MPa?

    c. ORC dari aliran pompa 5 MPa dan 6 MPa? Mengapa keduanya berbeda?

    d. air yang bersirkulasi pada ORC dan greenhouse pada bagian a) ?

    Asumsi :

    Steady state

    Sistem terbuka

    Energi kinetik dan energi potensial diabaikan

    a. Menghitung kerja keluaran expander

    Expander

    Neraca Energi Expander

    = +

    ( +

    2

    2+ )

    ( +

    2

    2+ )

    0 = + 11 22

    = 1 2

    Aliran 1

    Superheated Vapor P = 5 Mpa dan T = 95oC, sehingga dari stem table didapatkan nilai

    1 = 1494,5 /

    1 = 4,7252

    .

    Aliran 2

    Suhu pada aliran 2 sama dengan suhu pada aliran 3 yang masuk dari kondensor. Namun

    pada saat memsuki kondensor fasa nya adalah cair jenuh, sedangkan pada aliran 3

  • DEPARTEMEN TEKNIK KIMIA UNIVERSITAS INDONESIA 6

    Termodinamika

    fasanya adalah campuran uap-air. Untuk T = 25oC , besar entropi yang didapatkan dari

    steam table

    = 1,121

    .

    = 5,0293

    .

    Karena expander bersifat isentropik sehingga s1 = s2

    1 = 2

    1 = () + (1 )

    4,7252 = (5,0293) + (1 )1,121

    4,7252 = 5,0293 + 1,121 1,121

    3,6047 = 3,9083

    = 0,9223

    Sehingga nilai h2s dapat diketahui

    2 = () + (1 )

    2 = 0,9223(1463,5) + (1 0,9223)298,25

    2 = 1372,97 /

    Diketahui efisiensi expander adalah 0,75

    =(/)

    (/)=

    12

    12

    0,75 =1494,5 2

    1494,5 1372,97

    1494,5 2 = 91,1475

    2 = 1403,35 /

    Pompa

    Neraca energi pada pompa

    = +

    ( +

    2

    2+ )

    ( +

    2

    2+ )

    = (3 4)

    = (4 3)

  • DEPARTEMEN TEKNIK KIMIA UNIVERSITAS INDONESIA 7

    Termodinamika

    Aliran 3

    Suhu pada aliran 3 T = 25oC, dari steam tabel didapatkan nilai entalpi, tekanan, dan

    volume spesifik

    3 = 0,00165 3

    3 = 1,00438

    3 = 298,25 /

    Aliran 4

    Pompa bersifat isentropik sehingga s3 = s4, dan besar entalpi pada aliran 4 dapat

    dihitung dengan menggunakan nilai efisiensi

    =(/)

    (/)=

    43

    43

    (

    )

    = 3(4 3)

    =3(4 3)

    4 3

    0,75 =0,00165 3 (5 1,00438) 106/2

    (4 298,25 )

    0,754 223,6875 / = 6592,77 . /

    0,754 223,6875 / = 6,59277 /

    4 = 307,04 /

    Boiler

    Neraca energi pada boiler

    = +

    ( +

    2

    2+ )

    ( +

    2

    2+ )

    = (4 1)

    = (1 4)

    1575 = (1494,5 307,04)

    = 1,326 /

    Dengan mengetahui laju air massa NH3, maka besar kerja expander dan besar kerja pompa

    dapat diketahui

    Kerja expander

    = 1 2

    = 1,326(1494,5 1403,35)

  • DEPARTEMEN TEKNIK KIMIA UNIVERSITAS INDONESIA 8

    Termodinamika

    = , /

    Kerja pompa

    = (4 3)

    = 1,326(307,04 298,25)

    = , /

    b. Menghitung kerja keluaran expander jika p4 = 6 Mpa

    Expander

    = +

    ( +

    2

    2+ )

    ( +

    2

    2+ )

    0 = + 11 22

    = 1 2

    Aliran 1

    Superheated Vapor P = 5 Mpa dan T = 95oC, sehingga dari stem table didapatkan nilai

    1 = 688,85 /

    1 = 2,49325

    .

    Pada boiler dan expander tidak terdapat pressure drop, sehingga tekanan pada aliran 4 dan

    aliran 1 sama. Pada saat aliran 1 mempunyai tekanan 6 Mpa dan suhu 95oC ammonia berada

    pada kondisi subcooled liquid, sehingga tidak dapat memasuki expander. Ketika memsuki

    expander fasa harus dalam kondisi superheated. Karena tidak dapat memasuki expander

    sehingga tidak ada kerja yang dihasilkan.

    c. Menghitung efisiensi siklus ORC

    Untuk P4 = 5 Mpa

    =

    100% =

    120,86 11,66

    1575 100% = 6,93%

    d. Menghitung mass flow rate air

    Laju alir air dapat dihitung dengan meninjau sistem pada kondensor

    Kondensor

    = +

    ( +

    2

    2+ )

    ( +

    2

    2+ )

    = 3 (2 3) = 2(6 5)

  • DEPARTEMEN TEKNIK KIMIA UNIVERSITAS INDONESIA 9

    Termodinamika

    Aliran 5

    Aliran 5 merupakan saturated liquid P = 1 bar dan T = 15oC

    5 = 62,99 /

    Aliran 6

    Aliran 5 merupakan saturated liquid P = 1 bar dan T = 20oC

    5 = 83,96 /

    Untuk P4 = 5 Mpa

    1,326(1403,35 298,25) = 2(83,96 62,99)

    = , /

    e. Untuk P4 = 5 MPa

    Stream 1 2 3 4 5 6

    Vapor fraction 1 0,9223 0 0 0 0

    T (C) 95 25 25 25 15 20

    P (bar) 50 10.0438 10,0438 50 1 1

    Mass flow rate (ton/h) 4,7736 4,7736 4,7736 4,7736 251,568 251,568

    3. Assignment 3 (35)

    A refrigeration system employing a two-stage compression with intercooling between the

    stages is shown in Figure 1 including the fluidpath in the T-S diagram. A central role is played

    by a liquid-vapor separator, called a flash chamber. Refrigerant exiting the condenser at state

    5 expands through a valve and enters the flash chamber at state 6 as a two-phase liquid-vapor

    mixture with quality x. In the flash chamber, the liquid and vapor components separate into

    two streams. Saturated vapor exiting the flash chamber enters the heat exchanger at state 9,

    where intercooling is achieved by means of a direct contact heat exchanger. Relatively low-

    temperature saturated vapor enters the heat exchanger at state 9, where it mixes with higher-

    temperature refrigerant leaving the first compression stage at state 2. A single mixed stream

    exits the heat exchanger at an intermediate temperature at state 3 and is compressed in the

    second compressor stage to the condenser pressure at state 4. Saturated liquid exiting the flash

    chamber at state 7 expands through a second valve into the evaporator. On the basis of a unit

    of mass flowing through the condenser, the fraction of the vapor formed in the flash chamber

    equals the quality xof the refrigerant at state 6.

  • DEPARTEMEN TEKNIK KIMIA UNIVERSITAS INDONESIA 10

    Termodinamika

    Data:

    Refrigerant 134a is the working fluid. Saturated vapor at -30C enters the compressor

    operating at lower pressure, condenser pressure is 12 bar, compressor(s) operates

    isentropically, and the refrigeration capacity of the system is 10 tons. The flash chamber and

    direct contact heat exchanger operate at 4 bar. Saturated liquid streams at 12 and 4 bar enter

    the high- and low-pressure expansion valves, respectively.

    Determine:

    For the two-stage system shown in Figure 1: (a) The power input the first and the second

    compressor (in kW), (b) The coefficient of performance for this system.

    For the simple one stage system shown in Figure 2: (a) The power input to the compressor (in

    kW), (b) The coefficient of performance for this system, (c) Which system has the higher

    coefficient of performance? Explain.

    Use the properties table of R-134a is given in the attachment and the following assumptions:

    Isentropic compression of the refrigerant to the condenser pressure.

    Heat transfer fom the refrigerant as it flows at constant pressure through the condenser.

    Throttling procss to a two-phase liquid-vapor mixture.

    Heat transfer to the refrigerant as it flows at constant pressure through the evaporator.

    12 bar

    4 bar

    12 bar

    4 bar 4 bar

    T1= -30C 1

    2

  • DEPARTEMEN TEKNIK KIMIA UNIVERSITAS INDONESIA 11

    Termodinamika

    Gambar 2.

    Gambar 3.

    JAWAB

    Diketahui :

    refrigerant 134a merupakan fluida kerja pada sistem refrigerasi kompresi dua tingkat

    dengan intercooling.

    Suhu uap jenuh saat memasuki kompresor (T1) =-30C

    Tekanan kondensor (P5) = 12 bar

    Kapasitas refrigerasi () = 10 ton = 35,17 kW

    Flash chamber dan heat exchanger bekerja pada tekanan (P7 dan P9) = 4 bar

    Asumsi:

    steady state

    perubahan energi kinetik dan energi potensial diabaikan (EK=EP=0)

    tidak ada pressure drop pada heat exchanger dan flash chamber

    Flash chamber dan heat exchanger bekerja secara adiabatis

    Kompresor bekerja secara isentropik

    Pada expansion valve terjadi proses throttling

    Ditanya :

    Pada gambar 1: (a) Kerja yang dilakukan pada tiap kompresor dalam kW, (b) Koefisien kinerja

    pada sistem.

    Pada gambar 2: (a) Kerja yang dilakukan pada kompresor dalam kW, (b) Koefisien kinerja

    pada sistem, (c) Sistem yang memiliki koefisien kinerja lebih baik, jelaskan.

    Penyelesaian :

  • DEPARTEMEN TEKNIK KIMIA UNIVERSITAS INDONESIA 12

    Termodinamika

    (a) Siklus refrijerasi dengan dua tingkat (b) Diagram T-s

    Kompresi dan intercooling kilat

    Gambar 4. (Moran dkk., 2015)

    Analisis :

    keadaan 1 :

    T1 = -30C (uap jenuh)

    h1 = 229,14 kJ/kg (steam table)

    s1 = 0.9434 kJ/kg.K (steam table)

    keadaan 2 :

    P2 = 4 bar

    s2s = s1

    h2 = 260,62 kJ/kg (superheated table)

    keadaan 5 :

    P5 = 12 bar (cairan jenuh)

    h5 = 115,76 kJ/kg (steam table)

    keadaan 6 :

    12 bar

    4 bar

    12 bar

    4 bar 4 bar

    T1= -30C 1

    2

    4 bar

  • DEPARTEMEN TEKNIK KIMIA UNIVERSITAS INDONESIA 13

    Termodinamika

    proses throttling, isentalpik

    h6 = h5 = 115,76 kJ/kg

    kualitas 6 dihitung saat tekanan P6= 4 bar yang didapat dari steam table, dengan nilai

    hf= 62,00 kJ/kg dan hg= 252,32 kJ/kg, didapatkan nilai:

    6 = + 6( )

    115,76 / = 62,00 / + 6(252,32 / 62,00 /)

    6 = 0,2825

    keadaan 7 :

    P7 = 4 bar (cairan jenuh)

    h7 = 62,00 kJ/kg (steam table)

    keadaan 8 :

    proses throttling, isentalpik

    h8 = h7 = 62,00 kJ/kg

    keadaan 9:

    P9 = 4 bar (uap jenuh)

    H9 = 252,32 kJ/kg (steam table)

    keadaan 3 :

    keadaan pada heat exchanger: fraksi aliran menuju flash chamber pada keadaan 6 yang

    keluar berupa uap jenuh pada keadaan 9 memiliki kualitas yang sama pada keadaan 6.

    Fraksi cairan yang meninggalkan flash chamber pada keadaan 7 adalah 1 6.

    (1 6)2 + 69 = 1. 3

    3 = (1 6)2 + 69

    3 = (1 0,2825)(260,62 /) + (0,2825)(252,32 /) = 258,28 /

    3 = 0,935 (superheated table dengan P3= 4 bar)

    keadaan 4 :

    P4 = 12 bar

    s4 =s3

    h4 = 281,63 kJ/kg (superheated table)

    a) Menentukan laju alir massa. Neraca energi evaporator :

    + 18 = 11

    = 1(1 8)

    1 =

    (1 8)=

    35,17 /

    229,14 / 62,00 /= 0,21 /

  • DEPARTEMEN TEKNIK KIMIA UNIVERSITAS INDONESIA 14

    Termodinamika

    Karena 1 6 merupakan jumlah fraksi dari total aliran yang melewati evaporator, maka:

    13

    = 1 6 3 =1

    1 6=

    0,21 /

    1 0,2825= 0,293 /

    maka, neraca energi pada kompresor 1 (kesetimbangan massa: 1 = 2)

    1 + 11 = 22

    = ( ) = , /(, / , /) = , /

    dan, neraca energi pada kompresor 2 (kesetimbangan massa: 3 = 4)

    2 + 33 = 44

    = ( ) = , /(, / , /) = , /

    b) Nilai koefisien kinerja / Coefficient Of Performance (COP):

    =

    + =

    , /

    , / + , /= ,

    Satu Sistem :

    (a) Siklus refrigerasi kompresi uap ideal (b) Diagram T-s

    Gambar 5. (Anonim, 2015)

    Siklus refrigerasi kompresi uap ideal dapat digambarkan pada gambar 5(a). Proses yang terjadi

    pada diagram T-s yang ditunjukkan pada gambar 5(b) :

    1-2 : Kompresi isentropis dalam kompresor

    2-3 : Pembuangan kalor secara isobaris dalam kondenser

    3-4 : Throttling dalam katup ekspansi atau tabung kapiler

    4-1 : Penyerapan kalor secara isobaris dalam evaporator

    Analisis :

    keadaan 1 :

    P=C

    T=C

    S=C

    P=C

    h=C

  • DEPARTEMEN TEKNIK KIMIA UNIVERSITAS INDONESIA 15

    Termodinamika

    T1 = -30C (uap jenuh)

    h1 = 229,14 kJ/kg (steam table)

    s1 = 0.9434 kJ/kg.K (steam table)

    keadaan 2s :

    P2 = 12 bar

    s2s = s1

    h2 = 284,39 kJ/kg (superheated table)

    keadaan 3 :

    P3 = 12 bar (Cairan jenuh)

    s4 =s3

    h3 = 115,76 kJ/kg (steam table)

    keadaan 4 :

    proses throttling, isentalpik

    h4 =h3 = 115,76 kJ/kg

    a) Menentukan laju alir massa. Neraca energi evaporator :

    + 14 = 11

    = 1(1 4)

    =

    =

    ,

    , / , /= , /

    maka, neraca energi pada kompresor (kesetimbangan massa: 1 = 2)

    + 11 = 22

    = ( ) = , /(, / , /) = ,

    b) Nilai koefisien kinerja /Coefficient Of Performance (COP) :

    =

    =35,17

    17,13 = 2,05

    c) Sistem yang memiliki kinerja yang lebih baik adalah sistem refrigerasi dengan dua

    kompresor, karena memiliki nilai coefficient of performance lebih tinggi daripada sistem

    refrigerasi kompresor tunggal.

    4. Assignment 4 (20)

    Superheated steam at 40 bar and 360C with mass flow rate of 11 kg/s is divided into two

    streams. The first stream enters a 90% efficient steam turbine which produces 2,24 MW of shaft

  • DEPARTEMEN TEKNIK KIMIA UNIVERSITAS INDONESIA 16

    Termodinamika

    work and the second stream enters a throttling valve. The streams exiting the valve and the

    turbine mix in a mixing chamber and flows into a condensor where steam becomes saturated

    liquid at 198,3C.

    Determine:

    (a) the temperature of the stream leaving the mixing chamber.

    (b) the mass flow rate through the valve, in kg/s

    (c) locate the four numbered states on an h-s diagram

    Neglect heat transfer with the surroundings, changes in kinetic and potential energy, and

    pressure drop in mixing chamber and condensor.

    JAWAB

    Gambar 6. Skema Sistem

    Asumsi :

    1. Proses sistem secara menyeluruh berlangsang secara Steady State

    2. Pada unit throttling valve proses berlangsung secara adiabatik sehingga tidak terjadi

    pertukaran kalor antara sistem dan lingkungan.

    3. Turbin bekerja pada keadaan isentropik.

    4. Perubahan energi kinetik, energi potensial, transfer kalor pada semua sistem dapat

    diabaikan.

    5. Perubahan tekanan pada mixing chamber dan condenser dapat diabaikan, sehingga P2

    = P3 = P4 = P5

    Tinjau dari aliran masuk pada titik 1 :

    Penentuan dan pada aliran 1 (meliputi 1a dan 1b)

  • DEPARTEMEN TEKNIK KIMIA UNIVERSITAS INDONESIA 17

    Termodinamika

    Dari steam tables pada buku Moran Saphiro diperoleh:

    1(40 bar, 360 C) = 3117,2 kJ/kg

    1(40 bar, 360 C) = 6,6215 kJ/kg. K

    Neraca massa pada splitter

    = 1 + 1

    11 = 1 + 1

    Splitter hanya membagi laju alir massa tanpa menimbulkan perubahan pada T, P, ,

    dan . Sehingga aliran 1a dan 1b hanya berbeda pada laju alir massanya.

    Tinjau dari aliran keluar pada titik 5

    Penentuan dan pada aliran 5

    Dari steam tables pada buku Moran Saphiro diperoleh:

    5(saturated liquid, 198,3 C) = 844,829 kJ/kg

    S5(saturated liquid, 198,3 C) = 2,3148 kJ/kg. K

    P5 (saturated liquid, 198,3 C) = 15 bar

    Sehingga P2 = P3 = P4 = P5 = 15 bar

    Tinjau neraca massa dan energi dari tiap sistem :

    Pada Turbin

    Neraca Massa

    1 = 2

    Neraca energi

    1= 1 2

    2240

    1= 3117,2 2

    Dengan mengasumsikan bahwa turbin bekerja pada kondisi isentropik, sehingga :

    =1 21 2

    Untuk memperoleh nilai 2 maka dicari dahulu 2 yang merupakan entalpi keluaran

    turbin apabila turbin bekerja secara reversibel (isentropik).

    =1 21 2

  • DEPARTEMEN TEKNIK KIMIA UNIVERSITAS INDONESIA 18

    Termodinamika

    0,9 =3117,2 23117,2 2

    Karena isentropik maka :

    2 = 1 = 6,6215 kJ/kg. K

    P2 = P5 = 15 bar

    Dengan menggunakan data 2 dan P2 dapat digunakan untuk menentukan 2

    dengan bantuan steam table, sehingga diperoleh:

    2 = 2878,967 /

    Karena turbin memiliki efisiensi maka turbin bekerja secara irreversibel sehingga:

    =1 21 2

    0,9 =3117,2 2

    3117,2 2878,967

    2 = 2902,79 /

    Setelah 2 dapat ditentukan dari steam table dengan interpolasi pada data 2 dan P2

    sehingga diperoleh

    2 = 241,49

    Dari persamaan neraca massa pada turbin diperoleh persamaan:

    2240

    1= 3117,2 2

    2240

    1= 3117,2 2902,79

    1 = 10,45 /

    Sehingga,

    1 = 11 1 = 11 10,45 = 0,55 /

    Pada Trottling Valve

    Neraca Massa Throttling Valve

    1 = 3

    + + =

    Asumsi pada Throttling Valve :

    Perubahan energi potensial diabaikan ( = 0)

    Perubahan energi kinetik diabaikan ( = 0)

  • DEPARTEMEN TEKNIK KIMIA UNIVERSITAS INDONESIA 19

    Termodinamika

    Berlangsung secara adiabatik ( = 0)

    Tidak ada kerja ( = 0)

    Maka persamaannya menjadi :

    = 0

    3 1 = 0

    3 = 1

    3. 3 = 1. 1

    Karena 3 = 1 maka,

    3 = 1

    3 = 3117,2 /

    P3 = 15 bar

    Dengan diketahuinya nilai 3 pada tekanan P3, dilakukanlah interpolasi untuk

    menentukan T3 sehingga didapat

    3 = 347,15

    Setelah itu dari T3 dan P3 dilakukan interpolasi untuk menentukan 3 sehingga

    diperoleh

    3 = 7,0905

    .

    Pada Mixing Chamber

    Neraca Massa

    4 = 2 + 3

    4 = 1 + 1

    Sehingga

    4 = 1 = 11 /

    Neraca Energi

    + + =

    Asumsi pada Mixing Chamber :

    Perubahan energi potensial diabaikan ( = 0)

    Perubahan energi kinetik diabaikan ( = 0)

    Berlangsung secara adiabatik ( = 0)

    Tidak ada kerja ( = 0)

  • DEPARTEMEN TEKNIK KIMIA UNIVERSITAS INDONESIA 20

    Termodinamika

    Maka persamaan neraca energinya menjadi:

    = 0

    4 (2 + 3) = 0

    4 = 2 + 3

    44 = 2. 2 + 3. 3

    44 = (10,45 2902,79) + (0,55 3117,2)

    4 = 2913,51 /

    P4 = 15 bar

    Dengan diketahuinya nilai 4 pada tekanan P4, dapat ditentukan nilai T4 dengan

    menggunakan steam table pada data 4 dan P4, sehingga didapat :

    T4 = 246,09 C

    Setelah itu dari T4 dan P4 dilakukan interpolasi untuk menentukan 4 sehingga

    diperoleh 4 = 6,6895

    .

    Titik T (C) P (bar) H (kJ/kg) S (kJ/kg.K)

    1 360 40 3117,2 6,6215

    2 241,49 15 2902,79 6,6215

    3 347,15 15 3117,2 7,0905

    4 246,09 15 2913,51 6,6895

    5 198,3 15 844,289 2,3147

  • DEPARTEMEN TEKNIK KIMIA UNIVERSITAS INDONESIA 21

    Termodinamika

    GRAFIK H-S

    1

    2

    4

    3

    5

    Critical

    Point

  • DEPARTEMEN TEKNIK KIMIA UNIVERSITAS INDONESIA 22

    Termodinamika

    DAFTAR PUSTAKA

    Anonim, http://www.chegg.com/homework-help/questions-and-answers/consider-vapor-

    compression-refrigeration-cycle-shown-figure-cycle-operates-steady-state-re-

    q3412734. Diakses pada 22 Maret 2015

    Moran, Michael J, Shapiro, Howard N, Boettner, Daisie D, & Bailey, Margaret B. (2010).

    Fundamentals of Engineering Thermodynamics. United States of America: John

    Wiley & Sons Inc.

    Smith, J. M., Van Ness, H. C., & Abbott, M. M. (2001). Introduction to Chemical

    Engineering Thermodynamics (6th ed.). U.S.A.: McGraw Hill.