DAX 10 THE HIGHEST POWERED DAX FOR A · PDF fileDAX 10 THE HIGHEST POWERED DAX FOR A...

4
www.brush.eu DAX 10 THE HIGHEST POWERED DAX FOR A GENERATION —— Offering solutions up to 200 MW —— Suitable for a variety of locations in a variety of environments —— Viable alternative to hydrogen-cooled generators

Transcript of DAX 10 THE HIGHEST POWERED DAX FOR A · PDF fileDAX 10 THE HIGHEST POWERED DAX FOR A...

Page 1: DAX 10 THE HIGHEST POWERED DAX FOR A · PDF fileDAX 10 THE HIGHEST POWERED DAX FOR A GENERATION ... —— Viable alternative to hydrogen-cooled generators. DAX 10 ... Cooling methodology

www.brush.eu

DAX 10 THE HIGHEST POWERED DAXFOR A GENERATION—— Offering solutions up to 200 MW—— Suitable for a variety of locations in a variety of environments—— Viable alternative to hydrogen-cooled generators

Page 2: DAX 10 THE HIGHEST POWERED DAX FOR A · PDF fileDAX 10 THE HIGHEST POWERED DAX FOR A GENERATION ... —— Viable alternative to hydrogen-cooled generators. DAX 10 ... Cooling methodology

DAX 10 AIR-COOlED GENERATOR

BRUSH has built on its extensive knowledge of supplying generators to both the gas and steam turbine market to offer a new and exciting range of air-cooled generators.

Building on over 130 years’ experience, the best design practices and manufacturing techniques have been utilized to extend the current range of air-cooled generators to 200 MW, for both 50 and 60 Hz applications.

The first of this new generation of DAX 10 generators has just completed its second year of successful operation.

The DAX 10 range of air-cooled generators offers a real alternative to the hydrogen-cooled generator, offering simpler maintenance and operation as well as lower auxiliary costs, whilst maintaining project-specific output and efficiency requirements.

The DAX 10 range of air-cooled generators is versatile for a number of different applications and a variety of different environments, available to operate in a range of local environmental conditions.

The DAX 10 range of air-cooled generators is fully compliant with the requirements of the relevant international standard specifications, including IEC and IEEE.

Based on real-build experience, the new DAX 10 range of generators will continue and contribute to BRUSH’s ability to meet demanding interface requirements of the turbine manufacturer, coupled with competitive prices and deliveries.

Principles of stator design

—— Sprung core to minimize vibrations onto foundations

—— Pressed endwindings for optimal heat dissipation

—— Radially ventilated corepack construction

—— Upgraded resin rich insulation utilizing new flat glass technology

Principles of rotor design

—— Directly-cooled, ensuring uniform flow and temperature along the length of the rotor

Cooling methodology

—— Cooled by air, either open air-cooled circuit or closed water: air circuit configuration

—— Cooling air is forced around the generator by means of two axial fans

—— Integral, multi-chamber cooling system to ensure uniform temperature profile throughout the length of the generator

Excitation system

—— Brushless or static options available

—— Excitation systems based on proven systems

Bearing arrangement

—— Endframe or pedestal arrangement available, depending on the active core length required for the application

Versatile to surroundings

—— Housing suitable for outdoor installation

—— Applicable for 50 & 60 Hz applications, both gas and steam turbine arrangements

OUTPUT VOLTAGE SPEED POwEr FACTOr

EFFiCiEnCy

50 Hz 200 MW Up to 17 kV 3000 rpm 0.8 Up to 99.1%

60 Hz 200 MW Up to 19 kV 3600 rpm 0.85 Up to 99.0%

rEASOnS TO ChOOSE BrUSh DAX 10 rAnGE OF Air-COOLED GEnErATOrS

—— BRUSH tried and tested design and manufacturing principles used throughout

—— Each generator designed to effectively meet project-specific requirements

—— Viable alternative to hydrogen-cooled generators, eliminating the risks of using hydrogen as the primary coolant

—— Technology based on proven generator designs working out in the field

—— The first of this new generation of DAX 10 generators has just completed its second year of successful operation

—— Suitable for a variety of turbine applications, frequency requirements and environmental conditions

Page 3: DAX 10 THE HIGHEST POWERED DAX FOR A · PDF fileDAX 10 THE HIGHEST POWERED DAX FOR A GENERATION ... —— Viable alternative to hydrogen-cooled generators. DAX 10 ... Cooling methodology

DAX 10 REFERENCE lIST

ACERRA, ITAly WASTE TO ENERGy PlANTPRODuCT —— 9H 664872/2Equivalent to —— DAX 10-305OuTPuT —— 120 MW, 141 MVAVOlTAGE —— 10.5 kV POWER FACTOR —— 0.85SPEED —— 3000 rpmEXCITATION —— Brushless excitationCOOlING —— TEWAC arrangementCOMMISSIONED —— In operation since 2009

KATOWICE, POlAND COMBINED HEAT & POWER PlANTPRODuCT —— 91H 664831/2Equivalent to —— DAX 10-390OuTPuT —— 120 MW, 150 MVAVOlTAGE —— 15.75 kV POWER FACTOR —— 0.80SPEED —— 3000 rpmEXCITATION —— Static excitationCOOlING —— TEWAC arrangementCOMMISSIONED —— In operation since 2000

RIGA, lATVIA COMBINED CyClE PlANTPRODuCT —— DAX 10-455OuTPuT —— 150 MW. 187.5 MVAVOlTAGE —— 15.75 kV POWER FACTOR —— 0.80SPEED —— 3000 rpmEXCITATION —— Static excitationCOOlING —— TEWAC arrangementCOMMISSIONED —— In operation since 2008

Page 4: DAX 10 THE HIGHEST POWERED DAX FOR A · PDF fileDAX 10 THE HIGHEST POWERED DAX FOR A GENERATION ... —— Viable alternative to hydrogen-cooled generators. DAX 10 ... Cooling methodology

TuRBOGENERATORS PRODuCT MAP

Mw

4-POlE GEARED STEAM AND GAS TuRBINE 10-60

2-POlE AIR-COOlED 10-200

2-POlE HyDROGEN-COOlED 200-375

2-POlE HyDROGEN AND WATER COOlED 250-1000

SERVED MARKETS

—— Utility

—— Power Generation

—— Oil & Gas

—— Aftermarket Support

BrUSh TUrBOGEnErATOrS Nottingham Road, Loughborough, Leicestershire, LE11 1EX, United Kingdom

T + 44 (0) 1509 611511 F + 44 (0) 1509 612436 E [email protected]

For more information about BRUSH Turbogenerators, please call us direct, email or visit our website.

SM00

0030

9