    ADDENDUM 1 Granite Springs PROJECT NO.: 17.107

    Addendum #: 1 DATE OF ISSUANCE: September 11, 2017

    Please make the following clarification and modifications to your construction documents. GENERAL PROJECT ITEMS

    1) The project requires Energy Star Certification per the Owner promises to WCDA. Therefore, the project will undergo inspection and blower door testing for each dwelling unit. Below are the expectations and requirements of the HERS rater to inspect and blower door test. The project must adhere to all drawing sheets indicating air sealing and caulking in the construction set. CONSTRUCTION ADMIN PROCEDURE & REQUIRED VERIFICATIONS: Oakwood Construction will notify Home Energy Services in writing, 1-1/2 weeks ahead of time when the following can be reviewed:

    1) Post framing inspections “before insulation install” HES Review will consist of looking at complete exterior air barrier installation. HES will review and provide a report and identify if corrections are needed.

    2) Pre-drywall inspections “Insulation is installed to proper levels and at Grade I quality” HES will review and provide a report and identify if corrections are needed.

    3) Final performance testing, at substantial completion, including:

    -Air barrier leakage testing (blower door each dwelling unit) -Total duct leakage testing (duct blaster) -Duct leakage to the outside (3rd floor units)

    -Zonal Pressure Balance Tests -Exhaust Ventilation Rate Verification Tests -HVAC supply and return static pressure tests -HERS modeling, documentation and submittal of final ratings.

    GENERAL ARCHITECTURAL ITEMS None CLARIFICATIONS and REQUESTS FOR SUBSTITUTIONS TO SPECIFICATIONS: None CLARIFICATIONS TO ARCHITECTURAL DRAWINGS:

  •  encompass v2 llc 

     1535 liberty lane suite 110b missoula mt 59808 & 1 east main street suite 204 bozeman mt 59715   office 406.540.4437 

    None STRUCTURAL ITEMS CLARIFICATIONS TO STRUCTURAL DRAWINGS: None CIVIL ITEMS CLARIFICATIONS TO CIVIL DRAWINGS: None MECHANICAL & PLUMBING ITEMS CLARIFICATIONS TO MECHANICAL DRAWINGS: See attached Mechanical Addendum #1 from Western Montana Engineering, Inc. CLARIFICATIONS TO PLUMBING DRAWINGS: See Attached. ELECTRICAL ITEMS CLARIFICATIONS TO ELECTRICAL DRAWINGS: None Attachments: Addendum #1 from Western Montana Engineering, Inc., Provided for the requirements for SUB Contractor required checklist completion: National Program Requirements Energy Star Certified Homes Version 3 – revision 8, HVAC Commissioning Checklist Energy Star Certified Homes Version 3 – revision 8, HVAC Design Report Energy Star Certified Homes Version 3 – revision 8, Provided for Contractor Clarification: Rater Design Checklist Energy Star Certified Homes Version 3 – revision 8 and Rater Field Checklist Energy Star Certified Homes Version 3 – revision 8 and Water Management System Builder Requirements). END ADDENDUM #1 ----------------------------------------------------------------------

  • Page 1 of 1 

    Fussell Engineering           Electrical Phone: 406‐721‐6996  2453 Dixon              Mechanical Phone: 406‐214‐2702  Missoula MT  59801     

    Addendum #1        Date:  September 11, 2017      Project:   Granite Springs Apartments      E. Jefferson and Avenue C, Cheyenne, Wyoming 

        1. Mechanical Drawings: 

    a. MP0.1, Cooling Equipment Schedule – Change CU‐1 from a Goodman GSX16‐018 to a Goodman  GSX13‐018. Change E‐1 from a Goodman CAPF1824B6 to a Goodman CAPF3636B6. 

    b. M2.1, General Notes – Delete Note 19. Duct‐mounted branch balance dampers are not  required. 

    c. 1/M2.1 – Add transfer grilles from bedrooms as indicated. See also MSK‐001.  d. 2/M2.1 – Add transfer grilles from bedrooms as indicated. See also MSK‐001.  e. 4/M2.1 – Provide larger E‐1 as indicated. See also Item 1.a. 

      2. Mechanical Specifications: 

    a. Section 233100 – Change Paragraph 2.07 to read the following:      2.07  DUCT PRESSURE TESTING   

    A.  Ductwork will be pressure tested by an independent consultant. Ductwork must not  leak in excess of 4 cfm per 100 square foot of surface area at 25 Pascals.  Contractor shall work with independent consultant and provide additional  ductwork sealing, if necessary, to meet the above requirement. 

      Attachments: 

    Sheet M2.1 with revisions  MSK‐001 

       

    END OF ADDENDUM   

  • C H

    E Y

    E N

    N E

    , W

    Y O

    M I N

    G

    M U

    L T

    I F

    A M

    I L Y

    A

    P A

    R T

    M E

    N T

    C

    O M

    P L E

    X F

    O R

    :

    G R

    A N

    I T

    E S

    P R

    I N

    G S

    A

    P A

    R T

    M E

    N T

    S

    16.120ev2 Job #:

    1535 liberty lane

    Phone: 406.540.4437

    missoula, montana

    59808

    suite 110b

    v2

    PERMIT SET: 08.04.17

    E . J E

    F F

    E R

    S O

    N a n d A

    V E

    N U

    E C

    2435 Dixon

    Missoula, MT 59801

    Fussell

    Engineering

    Phone: (406) 721-6996

    M2.1

    UNIT

    PLANS

    HVAC

    ACRYLICSHOWERSFREEWILLK-12100-C ACRYLICSHOWERSFREEWILLK-12100-C

    BEDROOM

    10

    BEDROOM

    9

    LIVING

    1

    BEDROOM

    8

    HALL

    5

    LAUNDRY

    6

    STORAGE

    13

    PATIO (1ST FLR)

    DECK (UPPER FLRS)

    14

    DINING

    2

    KITCHEN

    3

    MECH

    15

    BATH

    7

    BATH

    12

    PANTRY

    4

    STORAGE

    13

    PATIO (1ST FLR)

    DECK (UPPER FLRS)

    14

    MECH

    15

    LIVING

    1

    DINING

    2

    KITCHEN

    3

    HALL

    5

    LAUNDRY

    6

    PANTRY

    4

    BATH

    12

    BATH

    7

    BEDROOM

    9

    BEDROOM

    8

    TWO BEDROOM HVAC PLAN

    1/4" = 1'0"

    1

    M2.1 1/4" = 1'0"

    2

    M2.1

    THREE BEDROOM HVAC PLAN

    CONSTRUCTION NOTES GENERAL NOTES

    TYPICAL FURNACE ELEVATION

    1/2" = 1'0"

    4

    M2.1

    OFFICE

    O101

    MECH ROOM

    M103

    OFFICE HVAC PLAN

    1/4" = 1'0"

    3

    M2.1

    8-8-17

    0 1' 5' 10' 0 1' 5' 10'

    TRANSFER GRILLES

    Addendum #1 09.11.171

    1

    1

    1

    1

    1

    1

    1

    AutoCAD SHX Text 1

    AutoCAD SHX Text 2

    AutoCAD SHX Text MAINTAIN MINIMUM 3' DISTANCE FROM ANY OPERABLE BUILDING OPENINGS.

    AutoCAD SHX Text 3

    AutoCAD SHX Text FINAL TEN FEET (MAX) TO AIR DEVICE BOOT MAY BE FLEX DUCT, TYPICAL.

    AutoCAD SHX Text 5

    AutoCAD SHX Text 6

    AutoCAD SHX Text COORDINATE DUCT AND AIR DEVICE INSTALLATION WITH OTHER ITEMS SUCH AS PLUMBING, LIGHTS, ELECTRICAL, ETC.

    AutoCAD SHX Text 1.

    AutoCAD SHX Text DO NOT RUN DUCTWORK ABOVE ELECTRICAL PANELS OR IN ELECTRICAL SERVICE CLEARANCES.

    AutoCAD SHX Text 2.

    AutoCAD SHX Text PIPE CONDENSATE FROM COOLING COILS AND FURNACES TO FD-1 IN MECHANICAL ROOM.

    AutoCAD SHX Text 3.

    AutoCAD SHX Text PROVIDE FLEX CONNECTORS AT SUPPLY AND RETURN DUCT CONNECTIONS TO FURNACES.

    AutoCAD SHX Text 4.

    AutoCAD SHX Text DRYER VENT CAPS SHALL HAVE BACKDRAFT DAMPER AND NO SCREEN. CAPS SHALL BE BROWN OR DARK BRONZE COLOR.

    AutoCAD SHX Text 5.

    AutoCAD SHX Text RANGE HOOD AND BATHROOM EXHAUST FAN VENT CAPS SHALL HAVE BACKDRAFT DAMPER AND BIRDSCREEN. CAPS SHALL BE BROWN OR DARK BRONZE COLOR.

    AutoCAD SHX Text 6.

    AutoCAD SHX Text MAINTAIN ALL CODE REQUIRED SERVICE AND REMOVAL CLEARANCES FOR FURNACES AND WATER HEATERS.

    AutoCAD SHX Text 10.

    AutoCAD SHX Text 12.

    AutoCAD SHX Text RANGE HOODS AND COMBINATION MICROWAVE/HOODS ARE SPECIFIED AND PROVIDED BY OTHER DIVISIONS. MECHANICAL CONTRACTOR TO PROVIDE AND INSTALL EXHAUST DUCTWORK AND WALL/ROOF CAPS. IN TYPE A UNITS, A RANGE HOOD RATHER THAN A MICROWAVE/HOOD WILL BE INSTALLED.

    AutoCAD SHX Text MAINTAIN MINIMUM OF 10' SEPARATION BETWEEN ALL VENTS - FURNACE VENTS, EXHAUST FAN DISCHARGES, PLUMBING VENTS, ETC. - AND ALL FRESH AIR INTAKES.

    AutoCAD SHX Text 14.

    AutoCAD SHX Text 15.

    AutoCAD SHX Text RUN FURNACE AND WATER HEATER VENTS HORIZONTALLY THROUGH MECHANICAL ROOMS AND ADJACENT STORAGE ROOMS AND THEN OUT THROUGH SIDEWALL. DO NOT USE CONCENTRIC TERMINATION KITS. PAINT EXPOSED PORTIONS OF VENT/INTAKE TO MATCH WALL COLOR.

    AutoCAD SHX Text 16.

    AutoCAD SHX Text DOORS SHALL BE UNDERCUT 1" TO ALLOW FOR RETURN OF AIR TO FURNACE.

    AutoCAD SHX Text DRYER VENT SHALL BE RIGID. DO NOT USE FLEXIBLE DUCTING.

    AutoCAD SHX Text 11.

    AutoCAD SHX Text 13.

    AutoCAD SHX Text MOUNT THERMOSTAT IN ALL UNITS AT 48" AFF TO TOP OF THERMOSTAT.

    AutoCAD SHX Text 7.

    AutoCAD SHX Text SEE