Download - LED...18W / 26W / 32W CFL Equivalent E361357 Ballast Compatible Type A Not Suitable for Enclosed Fixtures ... Sylvania QTP 2x26CF/UNV S PEM Sylvania QTP 2X26CF/UNV DM Sylvania QTP

Transcript
  • • SimplyPlug&Play:BallastCompatible(Check the Ballast Compatibility List on last page).NoWiringChangeNecessary.

    • FullBrightnesswithInstantOnandInstantRestrike

    • OptimalDesignforHorizontalorVerticalMountSockets

    • >80CRIforGreatVisibility

    • SuitableforDryorDampLocation

    • LowPowerConsumption

    • UniversalVoltage:100-277V,AC

    • Heat&ImpactResistant,UVProtected,Non-Yellowing,OpticalGradeLens

    • ExcellentHeatDissipationwithProprietary-DesignedHeatSink

    • CoolOperation:DoesnotaddtoHeatLoad(upto90%lessheatthan Incandescent)whileproducingBrilliantlyBrightLight

    • Non-Combustible.MadefromFlameRetardant,EngineeredPolymer, theBaseisMechanicallyStrongandHeat-Resistantupto435°F(225°C)

    • SafeandReliable:IsolatedCircuitDesign

    • Maintenance-FreeOperation:Lastsupto50timeslongerthan IncandescentBulb.LowersCostsbyReducingRelampFrequency

    •Safe:ContainNoHazardousMaterials;RoHSCompliant:NoLead, Mercury,ToxicMetalsorArsenicGases.NoDisposalRequirements. FacilitatesLEED®points

    •NoElectro-Magnetic(EMi)orRadioFrequencyInterference(RFi)

    •EnvironmentallyFriendly:98%oftheHyLiteLEDLampisRecyclable

    Page:1of3

    HighPerformance10WLEDPlug&PlayDimmablePLLamp

    TheHyLiteLEDPlug&PlayDimmablePLLampisanidealEnergy-EfficientreplacementforCFLandIncandescentBulbinstallationsinExistingandNewFixtures.The10WLEDPlug&PlayPLLampprovidesEnergy-EfficientIlluminationataWideBeamAngleof120°andreplaces18W/26W/32WCFLBulbs,effectivelyreducingEnergyConsumptionby44%-62%-69%,andasmuchas90%whenreplacing100WIncandescentBulbs.HyLiteLEDPLLampsareratedatupto50,000hoursofLampLife.Thisis50timeslongerthanatraditionalIncandescentBulb,and7timeslongerthanaCFLBulb.ThissignificantlyreducesEnergyUsageandCostsaswellasMaintenanceExpenditures.

    IdealforHigh-qualityIlluminationin:

    • DownLights • WallScones • WallPacks

    • CeilingLights • Bollards • DecorativeLighting

    • TaskLighting • AccentLighting • PedestrianTunnels

    • PendantLights • WalkwayLighting • StairwellLighting

    • CorridorLighting • CarriageLanterns

    IncreasedSustainability

    Up to50,000Hours

    Longer Life

    Reduction ofup to 90%

    Energy Costs

    Radiation-FreeNo Humming

    IRUV

    No IR/UV

    No Noise

    LM-80 TestedISTMT Tested

    Reliability

    Vibration andShock Resistant

    Solid State

    79 LpWLM-79 Tested

    Lumen Efficacy

    Reliable andLong-Lasting

    Warranty

    5years

    LowConsumption

    Power

    Zero Interference

    No EMi / RFi

    Wide andUniform

    Beam Angle

    120°

    PLUG-iN LAMP TMLED

    Lampcanbeorientedinanyposition-doesnotaffectordiminishthelifeofthelamp

    Universal Burning Positioning

    BaseDown

    BaseSideways

    BaseUp

    NOLEAD, MERCURY, HEAVY METALS

    OR TOXIC GASES

    98%RECYCLABLE

    1.75”

    (45m

    m)

    0.6”

    (15m

    m)

    6.1"

    (155

    mm

    )

    1.4” (35mm)

    10WHL-G24A-10W

    Incandescent Halogen CFL HyLite

    100W 55W 18W / 26W / 32W 10W

    90% 82% 44%-62%-69% Energy Savings (%)

    Replacewith 10WHL-G24A-10W

    350° Rotatable Base for

    Directional Lighting

    18W / 26W / 32WCFL Equivalent

    E361357

    Type ABallast Compatible

    Not Suitable for

    Enclosed Fixtures

  • • ToPreventearlyLampFailure,LampshouldonlybeinstalledinOperatingEnvironmentsrangingfromaMinimumof-20°C(-4°F)toaMaximumof+45°C(113°F)

    • Efficacy:79LpW* • CRI:>80 • BeamAngle:120º • Max.THD(%):0.9 • Protection:IP20 • RatedLife:50,000Hrs.* • Warranty:5Years

    • AmbientWorkingTemperature:-4ºF~+113ºF(-20ºC~+45ºC) • BaseType:G24 • UniversalInputVoltage

    • CCT:3500K(NeutralWhite),4000K(CoolWhite)and5000K(DayLight). 100~277V,AC50/60Hz.

    * Depending upon Ballast

    ** Depending upon the ambient temperature of the installation location

    Page:2of3

    HyLite PL Lamp, HL-G24A-10W

    Photometrics

    Intensity: (Unit, cd)0

    30

    60

    90

    120

    150-/+180

    -150

    -120

    -90

    -60

    -30

    Note: The Curves indicate the illuminated area and the average illumination when the luminaire is at different distance

    1 m3.3 ft.

    Height

    2 m6.5 ft.

    3 m9.8 ft.

    4 m13.1 ft.

    5 m16.4 ft.

    Angle: 112.7° DiameterCenter E (lx/fc)

    3.06 m10 ft.

    6.11 m20 ft.

    9.16 m30 ft.

    12.22 m40 ft.

    15.27 m50 ft.

    263.12 lx24.44 fc

    65.78 lx6.11 fc

    29.24 lx2.72 fc

    16.45 lx1.53 fc

    10.53 lx0.98 fc

    Ave. E (lx/fc)

    106.7 lx9.91 fc

    26.67 lx2.48 fc

    11.85 lx1.10 fc

    6.67 lx0.62 fc

    4.27 lx0.4 fc

    IlluminanceDistance Curve

    0

    53.4

    106.9

    160.3

    213.8

    267.2 Angle [50% Max.] [10% Max]C180/360 112.7° 169.2°C0/180 112.7° 169.2°C90/270 106.1° 159.0°

    OrderingforHyLite10WLEDPlug&PlayPLLampwithG24Base

    Model Suffix (CCT,ºK)

    HL-G24A-10W -35K 3500K=NeutralWhite(NW) -40K 4000K=CoolWhite(CW) -50K 5000K=DayLight(DL)

    As part of the company’s continuous product improvement program, HyLite reserves the right to change materials or modify the design of its product without notification. All Specifications subject to change without notice. All values are design and/or typical values when measured under laboratory conditions. Actual Values depend upon the ambient temperature of the installation location. Please consult factory for your specific requirements.

    Model Delivered InputLine Dimensions&Weight(each) No. Watts Lumens* Current Width Height NetWeight

    HL-G24A-10W 10 778 36mA~100mA 1.4”(35mm) 6.1”(155mm) 6oz.(170g)PLUG-iN LAMP TMLED

    Type ABallast Compatible

    WARNINGNotSuitableforTotallyEnclosedLuminairesorFullyEnclosedFixtures

    Warning:HyLiteLED10W“TypeA”Plug-inLampsaredesignedtoworkoff100V~277V,AC.HyLiteLED10W“TypeA”Plug-inLampsarecompatiblewithElectronicBallasts.SeeBallastCompatibleList.HyLiteLED10W“TypeA”Plug-inLampsareonlyDimmable ifusedwithDimmableElectronicBallasts.Itistheuser’sresponsibilitytocheckandverifywhethertheElectronicBallastisDimmableorNon-Dimmable.

    FailuretoFollowInstructionswillVOIDWarranty.ItcanalsoresultinanElectricShock,orFire.NOTFORTOTALLYENCLOSEDLUMINAIRESOREMERGENCYLIGHTING.NOTFORUSEWITHDIMMERS.

    Warning - Risk of Fire or Electric Shock• DisableallPowertotheLampbeforeInspection,Installation,orRemoval.FailuretodosowillcreateaHazardousandFatalWorkingEnvironment.TheInstallermustdetermineandverify whether120Vto277VACisbeingutilizedattheLuminairebeforeInstallation.ImproperVoltagematchingcanresultinPerformanceDegradationand/orPhysicalDamage.

    • WiringmodificationforHyLiteLEDLampInstallationrequiresknowledgeofLuminaireElectricalSystems.Ifnotqualified,DONOTattemptInstallation.ContactaQualifiedElectrician. DONOTMakeorAlteranyOpenHolesinanEnclosureforWiringorElectricalComponentsduringInstallation.

    • SuitableforuseinDryorDampLocations.DonotusewheredirectlyexposedtoLiquid,Vapor,RainorWeather.Non-Submergible(notwatertight).Lampmustbeinstalledinaccordancewith National,State,and/orLocalElectricalCodes.DoNotOpen–NoUserServiceablePartsInside.

    • TopreventearlyLampfailure,LampshouldonlybeinstalledinOperatingEnvironmentsrangingfromaminimumof-20°C(-4°F)toamaximumof+45°C(113°F).

    • LuminaireWiring,Ballast,orotherElectricalPartsmaybeDamagedwhenInstalling.AlwayscheckforenclosedWiringandComponents.DONOTBlockLightemanatingfromProductinWhole orPart,asthismayCauseanUnsafeCondition.TopreventWiringDamageorAbrasion,DONOTexposeWiringtoedgesofSheetMetalorotherSharpObjects.

    • OperateinFixturesthatprovidetheFreeFlowofAiraroundtheLampHeatSink.InEnclosedFixtures,ensuretheLamphasenoughSpaceforHeatDissipation.ThiswillensureLumen MaintenanceandextenditsWorkingLife.WhenproductsareusedinOutdoorFixtures,ensurethespaceisWaterproofandWellVentilated.

    • NotforuseonaDimmerorRemoteControls.ThisLampmustbecontrolledonlybyeitheraSwitchoranElectronicPhotosensor.DonotuseaMechanicalSensor.

    • NotintendedforusewithEmergencyExitFixturesorEmergencyExitLights.

    • InstallingSurge/LightningProtectorsisHighlyRecommendedandhelpstoEliminatePrematureDriverFailurecausedbySurgesandPowerFluctuations.

    Not Suitable for

    Enclosed Fixtures

  • Page:3of3

    TheListbelowisbasedinpartoninformationprovidedbytheBallastManufacturerandTestingwasdoneonastableACPowerSupplyunderLaboratoryConditions,whichmayormaynotberepresentativeofyourparticularEnd-useConditions.HyLiteLED10W“TypeA”Plug-inLampsareonlyDimmableifusedwithDimmableElectronicBallasts. It istheuser’sresponsibilitytocheckandverifywhethertheElectronicBallast isDimmableorNon-Dimmable.

    ApplicationsandConditionsofusearemanyandvariedandbeyondourcontrol,sopurchasersandusersshouldmaketheirowndeterminationsastothesuitabilityofaLamp-BallastcombinationfortheirownparticularApplicationandUse.CompatibilitymayalsoextendtoBallastsbeyondthislist,soperforminganOn-SiteTestbeforeInstallationisStronglyRecommended.FailuretoFollowInstructionswillVOIDWarranty.

    HyLiteLED“TypeA”Plug-inLampsandBulbsBallastCompatibleList

    HyLiteHyLiteLED“TypeA”Plug-inLampsandOmni-BulbshavebeentestedforcompatibilitytoworkflawlesslywiththeBallastsshownabove.HyLiteiscontinuallytesting“TypeA”Plug-inLampsandOmni-BulbsonvariousotherBallasts.WewillcontinuetoupdatetheBallastCompatibilityListasadditionalmodelsaretested.PleasecontactHyLiteaboutanyBallastsnotshownonthislist.

    Note:RiskofFireorElectricShock.BeforeInstallation,checkSpecificationsforthemostCurrentBallastCompatibilityList.IftheBallastmodeldoesnotappearonthisList,pleaseDONOTInstall,untilyoucheckwithHyLite.InstalllingHyLiteLED“TypeA”Plug-inLampsandOmni-BulbswithoutverifyingitagainsttheBallastCompatibleListandwithouttestingtheCompatibilitywillvoidallWarranties.Itistheuser’sresponsibilitytocheckandverifywhethertheElectronicBallastisDimmableorNon-Dimmable.ReadandUnderstandallInstallationInstructionsbeforeinstallingHyLiteLED“TypeA”Plug-inLampsandOmni-Bulbs.

    Compatible Not Compatible

    Ballast Model120V 277V 120V 277V

    Advance ICF-2S26-M1-BSAdvance ICF-2S26-H1-LDAdvance ICF-2S13-H1-LDAdvance ICF-2S18-H1-LDAdvance ICF-2S18-M1-BSAdvance IZT-2S26-M5-LDAdvance ICF-2S26-M1-BS-QSGE Proline GEC226-MVPS-BESGE Proline GEC226-MVPS-3WGE Proline GEC226-MVPS-SEGE GEC218-MVPS-3WGE GEC218-MVPS-BESGE GEC213-MVPS-3WHatch HC213PS/UV/DHatch HC226PS/UV/DHoward EP2/18CF/MV/2Howard EP2/26CF/MV/2LumaPro 4KGJ7LumaPro 16X954LumaPro 16X959LumaPro 4KGJ8Robertson PSM226CQMVDWCESylvania QTP 2x26CF/UNV S PEMSylvania QTP 2X26CF/UNV DMSylvania QTP 1/2x18CF UNV DMTriad C2642UNVSETriad C2642UNVMETriad C218UNVME

    One Lamp Two Lamp

    ©2017-2020HyLiteLED,LLC.,USA Formoreinformation,pleasevisit:https://hyliteledlighting.com/ 022820

    Not Suitable for

    Enclosed Fixtures