• SimplyPlug&Play:BallastCompatible(Check the Ballast Compatibility List on last page).NoWiringChangeNecessary.
• FullBrightnesswithInstantOnandInstantRestrike
• OptimalDesignforHorizontalorVerticalMountSockets
• >80CRIforGreatVisibility
• SuitableforDryorDampLocation
• LowPowerConsumption
• UniversalVoltage:100-277V,AC
• Heat&ImpactResistant,UVProtected,Non-Yellowing,OpticalGradeLens
• ExcellentHeatDissipationwithProprietary-DesignedHeatSink
• CoolOperation:DoesnotaddtoHeatLoad(upto90%lessheatthan Incandescent)whileproducingBrilliantlyBrightLight
• Non-Combustible.MadefromFlameRetardant,EngineeredPolymer, theBaseisMechanicallyStrongandHeat-Resistantupto435°F(225°C)
• SafeandReliable:IsolatedCircuitDesign
• Maintenance-FreeOperation:Lastsupto50timeslongerthan IncandescentBulb.LowersCostsbyReducingRelampFrequency
•Safe:ContainNoHazardousMaterials;RoHSCompliant:NoLead, Mercury,ToxicMetalsorArsenicGases.NoDisposalRequirements. FacilitatesLEED®points
•NoElectro-Magnetic(EMi)orRadioFrequencyInterference(RFi)
•EnvironmentallyFriendly:98%oftheHyLiteLEDLampisRecyclable
Page:1of3
HighPerformance10WLEDPlug&PlayDimmablePLLamp
TheHyLiteLEDPlug&PlayDimmablePLLampisanidealEnergy-EfficientreplacementforCFLandIncandescentBulbinstallationsinExistingandNewFixtures.The10WLEDPlug&PlayPLLampprovidesEnergy-EfficientIlluminationataWideBeamAngleof120°andreplaces18W/26W/32WCFLBulbs,effectivelyreducingEnergyConsumptionby44%-62%-69%,andasmuchas90%whenreplacing100WIncandescentBulbs.HyLiteLEDPLLampsareratedatupto50,000hoursofLampLife.Thisis50timeslongerthanatraditionalIncandescentBulb,and7timeslongerthanaCFLBulb.ThissignificantlyreducesEnergyUsageandCostsaswellasMaintenanceExpenditures.
IdealforHigh-qualityIlluminationin:
• DownLights • WallScones • WallPacks
• CeilingLights • Bollards • DecorativeLighting
• TaskLighting • AccentLighting • PedestrianTunnels
• PendantLights • WalkwayLighting • StairwellLighting
• CorridorLighting • CarriageLanterns
IncreasedSustainability
Up to50,000Hours
Longer Life
Reduction ofup to 90%
Energy Costs
Radiation-FreeNo Humming
IRUV
No IR/UV
No Noise
LM-80 TestedISTMT Tested
Reliability
Vibration andShock Resistant
Solid State
79 LpWLM-79 Tested
Lumen Efficacy
Reliable andLong-Lasting
Warranty
5years
LowConsumption
Power
Zero Interference
No EMi / RFi
Wide andUniform
Beam Angle
120°
PLUG-iN LAMP TMLED
Lampcanbeorientedinanyposition-doesnotaffectordiminishthelifeofthelamp
Universal Burning Positioning
BaseDown
BaseSideways
BaseUp
NOLEAD, MERCURY, HEAVY METALS
OR TOXIC GASES
98%RECYCLABLE
1.75”
(45m
m)
0.6”
(15m
m)
6.1"
(155
mm
)
1.4” (35mm)
10WHL-G24A-10W
Incandescent Halogen CFL HyLite
100W 55W 18W / 26W / 32W 10W
90% 82% 44%-62%-69% Energy Savings (%)
Replacewith 10WHL-G24A-10W
350° Rotatable Base for
Directional Lighting
18W / 26W / 32WCFL Equivalent
E361357
Type ABallast Compatible
Not Suitable for
Enclosed Fixtures
-
• ToPreventearlyLampFailure,LampshouldonlybeinstalledinOperatingEnvironmentsrangingfromaMinimumof-20°C(-4°F)toaMaximumof+45°C(113°F)
• Efficacy:79LpW* • CRI:>80 • BeamAngle:120º • Max.THD(%):0.9 • Protection:IP20 • RatedLife:50,000Hrs.* • Warranty:5Years
• AmbientWorkingTemperature:-4ºF~+113ºF(-20ºC~+45ºC) • BaseType:G24 • UniversalInputVoltage
• CCT:3500K(NeutralWhite),4000K(CoolWhite)and5000K(DayLight). 100~277V,AC50/60Hz.
* Depending upon Ballast
** Depending upon the ambient temperature of the installation location
Page:2of3
HyLite PL Lamp, HL-G24A-10W
Photometrics
Intensity: (Unit, cd)0
30
60
90
120
150-/+180
-150
-120
-90
-60
-30
Note: The Curves indicate the illuminated area and the average illumination when the luminaire is at different distance
1 m3.3 ft.
Height
2 m6.5 ft.
3 m9.8 ft.
4 m13.1 ft.
5 m16.4 ft.
Angle: 112.7° DiameterCenter E (lx/fc)
3.06 m10 ft.
6.11 m20 ft.
9.16 m30 ft.
12.22 m40 ft.
15.27 m50 ft.
263.12 lx24.44 fc
65.78 lx6.11 fc
29.24 lx2.72 fc
16.45 lx1.53 fc
10.53 lx0.98 fc
Ave. E (lx/fc)
106.7 lx9.91 fc
26.67 lx2.48 fc
11.85 lx1.10 fc
6.67 lx0.62 fc
4.27 lx0.4 fc
IlluminanceDistance Curve
0
53.4
106.9
160.3
213.8
267.2 Angle [50% Max.] [10% Max]C180/360 112.7° 169.2°C0/180 112.7° 169.2°C90/270 106.1° 159.0°
OrderingforHyLite10WLEDPlug&PlayPLLampwithG24Base
Model Suffix (CCT,ºK)
HL-G24A-10W -35K 3500K=NeutralWhite(NW) -40K 4000K=CoolWhite(CW) -50K 5000K=DayLight(DL)
As part of the company’s continuous product improvement program, HyLite reserves the right to change materials or modify the design of its product without notification. All Specifications subject to change without notice. All values are design and/or typical values when measured under laboratory conditions. Actual Values depend upon the ambient temperature of the installation location. Please consult factory for your specific requirements.
Model Delivered InputLine Dimensions&Weight(each) No. Watts Lumens* Current Width Height NetWeight
HL-G24A-10W 10 778 36mA~100mA 1.4”(35mm) 6.1”(155mm) 6oz.(170g)PLUG-iN LAMP TMLED
Type ABallast Compatible
WARNINGNotSuitableforTotallyEnclosedLuminairesorFullyEnclosedFixtures
Warning:HyLiteLED10W“TypeA”Plug-inLampsaredesignedtoworkoff100V~277V,AC.HyLiteLED10W“TypeA”Plug-inLampsarecompatiblewithElectronicBallasts.SeeBallastCompatibleList.HyLiteLED10W“TypeA”Plug-inLampsareonlyDimmable ifusedwithDimmableElectronicBallasts.Itistheuser’sresponsibilitytocheckandverifywhethertheElectronicBallastisDimmableorNon-Dimmable.
FailuretoFollowInstructionswillVOIDWarranty.ItcanalsoresultinanElectricShock,orFire.NOTFORTOTALLYENCLOSEDLUMINAIRESOREMERGENCYLIGHTING.NOTFORUSEWITHDIMMERS.
Warning - Risk of Fire or Electric Shock• DisableallPowertotheLampbeforeInspection,Installation,orRemoval.FailuretodosowillcreateaHazardousandFatalWorkingEnvironment.TheInstallermustdetermineandverify whether120Vto277VACisbeingutilizedattheLuminairebeforeInstallation.ImproperVoltagematchingcanresultinPerformanceDegradationand/orPhysicalDamage.
• WiringmodificationforHyLiteLEDLampInstallationrequiresknowledgeofLuminaireElectricalSystems.Ifnotqualified,DONOTattemptInstallation.ContactaQualifiedElectrician. DONOTMakeorAlteranyOpenHolesinanEnclosureforWiringorElectricalComponentsduringInstallation.
• SuitableforuseinDryorDampLocations.DonotusewheredirectlyexposedtoLiquid,Vapor,RainorWeather.Non-Submergible(notwatertight).Lampmustbeinstalledinaccordancewith National,State,and/orLocalElectricalCodes.DoNotOpen–NoUserServiceablePartsInside.
• TopreventearlyLampfailure,LampshouldonlybeinstalledinOperatingEnvironmentsrangingfromaminimumof-20°C(-4°F)toamaximumof+45°C(113°F).
• LuminaireWiring,Ballast,orotherElectricalPartsmaybeDamagedwhenInstalling.AlwayscheckforenclosedWiringandComponents.DONOTBlockLightemanatingfromProductinWhole orPart,asthismayCauseanUnsafeCondition.TopreventWiringDamageorAbrasion,DONOTexposeWiringtoedgesofSheetMetalorotherSharpObjects.
• OperateinFixturesthatprovidetheFreeFlowofAiraroundtheLampHeatSink.InEnclosedFixtures,ensuretheLamphasenoughSpaceforHeatDissipation.ThiswillensureLumen MaintenanceandextenditsWorkingLife.WhenproductsareusedinOutdoorFixtures,ensurethespaceisWaterproofandWellVentilated.
• NotforuseonaDimmerorRemoteControls.ThisLampmustbecontrolledonlybyeitheraSwitchoranElectronicPhotosensor.DonotuseaMechanicalSensor.
• NotintendedforusewithEmergencyExitFixturesorEmergencyExitLights.
• InstallingSurge/LightningProtectorsisHighlyRecommendedandhelpstoEliminatePrematureDriverFailurecausedbySurgesandPowerFluctuations.
Not Suitable for
Enclosed Fixtures
-
Page:3of3
TheListbelowisbasedinpartoninformationprovidedbytheBallastManufacturerandTestingwasdoneonastableACPowerSupplyunderLaboratoryConditions,whichmayormaynotberepresentativeofyourparticularEnd-useConditions.HyLiteLED10W“TypeA”Plug-inLampsareonlyDimmableifusedwithDimmableElectronicBallasts. It istheuser’sresponsibilitytocheckandverifywhethertheElectronicBallast isDimmableorNon-Dimmable.
ApplicationsandConditionsofusearemanyandvariedandbeyondourcontrol,sopurchasersandusersshouldmaketheirowndeterminationsastothesuitabilityofaLamp-BallastcombinationfortheirownparticularApplicationandUse.CompatibilitymayalsoextendtoBallastsbeyondthislist,soperforminganOn-SiteTestbeforeInstallationisStronglyRecommended.FailuretoFollowInstructionswillVOIDWarranty.
HyLiteLED“TypeA”Plug-inLampsandBulbsBallastCompatibleList
HyLiteHyLiteLED“TypeA”Plug-inLampsandOmni-BulbshavebeentestedforcompatibilitytoworkflawlesslywiththeBallastsshownabove.HyLiteiscontinuallytesting“TypeA”Plug-inLampsandOmni-BulbsonvariousotherBallasts.WewillcontinuetoupdatetheBallastCompatibilityListasadditionalmodelsaretested.PleasecontactHyLiteaboutanyBallastsnotshownonthislist.
Note:RiskofFireorElectricShock.BeforeInstallation,checkSpecificationsforthemostCurrentBallastCompatibilityList.IftheBallastmodeldoesnotappearonthisList,pleaseDONOTInstall,untilyoucheckwithHyLite.InstalllingHyLiteLED“TypeA”Plug-inLampsandOmni-BulbswithoutverifyingitagainsttheBallastCompatibleListandwithouttestingtheCompatibilitywillvoidallWarranties.Itistheuser’sresponsibilitytocheckandverifywhethertheElectronicBallastisDimmableorNon-Dimmable.ReadandUnderstandallInstallationInstructionsbeforeinstallingHyLiteLED“TypeA”Plug-inLampsandOmni-Bulbs.
Compatible Not Compatible
Ballast Model120V 277V 120V 277V
Advance ICF-2S26-M1-BSAdvance ICF-2S26-H1-LDAdvance ICF-2S13-H1-LDAdvance ICF-2S18-H1-LDAdvance ICF-2S18-M1-BSAdvance IZT-2S26-M5-LDAdvance ICF-2S26-M1-BS-QSGE Proline GEC226-MVPS-BESGE Proline GEC226-MVPS-3WGE Proline GEC226-MVPS-SEGE GEC218-MVPS-3WGE GEC218-MVPS-BESGE GEC213-MVPS-3WHatch HC213PS/UV/DHatch HC226PS/UV/DHoward EP2/18CF/MV/2Howard EP2/26CF/MV/2LumaPro 4KGJ7LumaPro 16X954LumaPro 16X959LumaPro 4KGJ8Robertson PSM226CQMVDWCESylvania QTP 2x26CF/UNV S PEMSylvania QTP 2X26CF/UNV DMSylvania QTP 1/2x18CF UNV DMTriad C2642UNVSETriad C2642UNVMETriad C218UNVME
One Lamp Two Lamp
©2017-2020HyLiteLED,LLC.,USA Formoreinformation,pleasevisit:https://hyliteledlighting.com/ 022820