WICONA series€¦ · Complete system advantages of the comprehensive WICLINE evo window series...
Transcript of WICONA series€¦ · Complete system advantages of the comprehensive WICLINE evo window series...
WICONA series
T E C H N O L O G Y F O R I D E A S
32
I N T R O D U C T I O N
32
Content
WICONA series
Stick system façades 4
Unitized façades 7
Integration sashes 8
Windows 9
Doors 12
Sliding systems 14
Phot
o: W
erne
r Hut
hmac
her
ADIDAS, Herzogenaurach kadawittfeldarchitektur Rupert App GmbH & Co.
T E C H N O L O G Y F O R I D E A S
54
Name / series Main advantages Applications / opening types Performance features Special functions Section drawing
■■ Basic series for individual adaptations according to the WICONA Unisys technology
■■ Sight line 50 mm■■ Profile depth 50 – 260 mm■■ Infill thickness 3 – 63 mm
■■ Curtain wall■■ Glass roof constructions■■ 3D spatial constructions
(Polygonal façades up to 45°)
■■ Uf until 1.2 W / (m2K)■■ Sound insulation until 47 dB■■ System tests according to
DIN EN 13830 for CE marking
■■ Burglar resistance in class WK1, WK2, WK3
■■ Bullet resistance in class FB4■■ Integrated sunshade
(special guide rails in external cover profiles)
Passive house curtain wall
■■ Certified passive house component (ift)
■■ Profile depth 50 – 260 mm■■ Infill thickness 24 – 51 mm■■ WICTEC 50 with complementary
special insulation profile
■■ Curtain wall■■ Polygonal façades up to 5°
■■ Uf until 0.74 W / (m2K)■■ Uw Passive house < 0.8 W / (m2K)■■ System tests according to
DIN EN 13830 for CE marking
■■ Burglar resistance in class WK1, WK2
Structural glazing curtain wall
■■ SG structural glazing technology■■ On the basis of WICTEC 50■■ With European Approval ETA
■■ Curtain wall■■ Glass roof constructions■■ Semi façades
(combined with pressure profiles)
■■ Uf until 1.5 W / (m2K)■■ System tests according to
DIN EN 13830 for CE marking
■■ Opening units in all-glass design: see integration sashes
SG Design with integrated pressure profile
■■ Integrated pressure profiles, overlying or flush to glass
■■ No SG-approval required■■ Profile width 43 or 51 mm
■■ Curtain wall with optical characteristics of a Structural glazing SG façade
■■ System tests according to DIN EN 13830 for CE marking
■■ Burglar resistance in class WK1
S T I C K S Y S T E M F A Ç A D E S
54
Name / series Main advantages Applications / opening types Performance features Special functions Section drawing
Add-on construction for steel or wood
■■ System for direct glazing on structures made from customary steel of wood profiles
■■ Sight line 50 mm■■ Sealing and tightness assured
by a continuous gasket
■■ Curtain wall■■ Glass roof constructions
■■ Uf until 1.2 W / (m2K)■■ System tests according to
DIN EN 13830 for CE marking
■■ Burglar resistance in class WK1, WK2
Mullion / mullion curtain wall
■■ Stick system with identical profiles for mullion and transom
■■ Straight profile cut, no notching required
■■ Sealing and tightness assured by a continuous gasket
■■ Curtain wall ■■ Uf until 1.2 W / (m2K)■■ System tests according to
DIN EN 13830 for CE marking
■■ Burglar resistance in class WK1, WK2
Fire protection
■■ Fire protection curtain wall■■ For glazing or panels up to
1.8 x 3.0 m or 2.4 x 1.4 m■■ With several national
general approvals
■■ Curtain wall■■ Overhead glazing until 0° slope■■ Polygonal constructions up to 5°
■■ Uf until 1.4 W / (m2K)■■ System tests according to
DIN EN 13830 for CE marking
■■ Fire resistance in class G30 / F30
S T I C K S Y S T E M F A Ç A D E S
76
S T I C K S Y S T E M F A Ç A D E S
Name / series Main advantages Applications / opening types Performance features Special functions Section drawing
■■ Basic series for individual adaptations according to the WICONA Unisys technology
■■ Sight line 60 mm■■ Profile depth 70 – 170 mm■■ Infill thickness 3 – 51 mm
■■ Curtain wall■■ Glass roof constructions■■ 3D spatial constructions
■■ Uf until 1.2 W / (m2K)■■ Sound insulation until 47 dB■■ System tests according to
DIN EN 13830 for CE marking
■■ Burglar resistance in class WK1, WK2, WK3
■■ Bullet resistance in class FB4
Fire protection
■■ Fire protection curtain wall■■ For glazing or panels up to
1.8 x 3.0 m or 2.4 x 1.4 m■■ With several national
general approvals
■■ Curtain wall■■ Overhead glazing until 0° slope
■■ Uf until 1.4 W / (m2K)■■ System tests according to
DIN EN 13830 for CE marking
■■ Fire resistance in class G30 / F30
Fire protection parapet
■■ Fire protection class W90■■ Exterior layer in glass
or aluminium
■■ Integration in stick curtain walls to prevent flash over of fire from storey to storey
76
U N I T I Z E D F A Ç A D E S
Name / series Main advantages Applications / opening types Performance features Special functions Section drawing
■■ Unitized curtain wall on stick system base
■■ Exterior glazing beads with mitre cut, leading to a picture frame design
■■ Sight lines 50 / 65 mm
■■ Unitized curtain wall for complete pre-assembly in the workshop, including glazing and parapet elements
■■ Unit size until 3.5 m height and 3.0 m width (storey height)
■■ Uf until 1.4 W / (m2K)■■ System tests according to
DIN EN 13830 for CE marking
■■ Exterior glazing beads with mitre cut, leading to a picture frame design
■■ Sight line 60 mm
■■ Unitized curtain wall for complete pre-assembly in the workshop, including glazing and parapet elements
■■ Unit size until 3.5 m height and 2.8 m width (storey height)
■■ Uf until 1.6 W / (m2K)■■ System tests according to
DIN EN 13830 for CE marking
98
I N T E G R A T I O N S A S H E S
Name / series Main advantages Applications / opening types Performance features Special functions Section drawing
Roof light vent sash
■■ Sight line 81 mm■■ Concealed hinges with
opening angle 90°■■ Glass level offset only 36 mm
■■ Application in WICTEC 50 / 60 glass roof constructions until 10° slope
■■ Sash size until 1.4 x 1.8 m or 1.8 x 1.4 m
■■ System tests according to DIN EN 14351-1 for CE marking
■■ NSHE (Natural smoke and heat exhaust ventilators)
■■ Glazing with pressure profile or spot holder
Lowering and projecting top-hung window SG Parallel outward opening window SG
■■ Outward opening sashes in Structural Glazing SG Design
■■ For manual or motorized operation
■■ Lowering and projecting top-hung window size until 1.5 x 2.5 m or 2.0 x 1.5 m
■■ Parallel outward opening sash size until 1.5 x 3.0 m or 2.0 x 1.5 m
■■ Uf until 1.6 W / (m2K)■■ System tests according to
DIN EN 14351-1 for CE marking
■■ Application in WICTEC 50SG Structural glazing curtain wall or in WICTEC 50 curtain wall with pressure profiles
See windows
■■ Complete system advantages of the comprehensive WICLINE evo window series
■■ Inward opening: Turn-tilt, turn, tilt, tilt-first, double casement
■■ Outward opening: Top-hung, Italian, pivot (horizontal / vertical)
■■ Uf until 1.4 W / (m2K)■■ Uw until 1.2 W / (m2K)■■ System tests according to
DIN EN 14351-1 for CE marking
■■ Burglar resistance in class WK1, WK2, WK3
■■ Concealed sash■■ Classic design
Ventilation flap
■■ Slim opening sash for manual ventilation
■■ Width 250 mm■■ Height until 2.25 m
■■ Turn sash made of only one thermally broken aluminium profile
■■ Uf until 1.6 W / (m2K)■■ Sound insulation until 41 dB
■■ Sound insulation in open position until 21 dB resp. 26 dB depending on the ventilation type
Example shown: concealed sash
98
W I N D O W S
Name / series Main advantages Applications / opening types Performance features Special functions Section drawing
■■ Basic series for individual adaptations according to the WICONA Unisys technology
■■ Profile depth 65 mm■■ Infill thickness 3 – 60 mm■■ Fittings concealed or visible,
until 160 kg sash weight
■■ Inward opening: Turn-tilt, turn, tilt, tilt-first, double casement, fanlight, parallel sliding / tilt, French window (window-door)
■■ Outward opening: Top-hung, Italian, French, pivot (horizontal / vertical)
■■ Uf until 1.4 W / (m2K)■■ Uw until 1.2 W / (m2K)■■ System tests according to
DIN EN 14351-1 for CE marking
■■ Burglar resistance in class WK1, WK2, WK3 and RC1, RC2, RC3
■■ Bullet resistance*■■ Integration in stick system
curtain walls■■ Minergie window (according to
Swiss Minergie standard)
■■ Basic series for individual adaptations according to the WICONA Unisys technology
■■ Profile depth 65 mm■■ Infill thickness 6 – 70 mm■■ Fittings concealed or visible,
until 160 kg sash weight
■■ Inward opening: Turn-tilt, turn, tilt, tilt-first, double casement, fanlight, parallel sliding / tilt, French window (window-door)
■■ Outward opening: Top-hung, Italian, French, pivot (horizontal / vertical)
■■ Uf until 1.2 W / (m2K)■■ Uw until 0.9 W / (m2K)■■ System tests according to
DIN EN 14351-1 for CE marking
■■ Burglar resistance in class WK1, WK2, WK3 and RC1, RC2, RC3
■■ Bullet resistance*■■ Integration in stick system
curtain walls
Minergie-P Module window
■■ Certified according to the Swiss Minergie-P Standard
■■ Profile depth 85 mm
■■ Double Casement turn window■■ Turn-tilt, with overlapping sash
■■ Uw according to Minergie-P specification < 0,8 W / (m2K)
Concealed sash
■■ Slim frame construction, no visible sash frame
■■ Profile depth 75 / 85 mm
■■ Inward opening: Turn-tilt, turn, tilt-first, double casement, fanlight
■■ Uf until 1.8 W / (m2K)■■ Uw until 1.0 W / (m2K)■■ System tests according to
DIN EN 14351-1 for CE marking
■■ Burglar resistance in class WK1, WK2, WK3 and RC1, RC2, RC3
■■ Integration in stick system curtain walls
* In preparation
10
Name / series Main advantages Applications / opening types Performance features Special functions Section drawing
Classic design
■■ 30° bevelled profiles with overlapping sash
■■ Profile depth 75 / 85 mm■■ Fittings concealed or visible,
until 160 kg sash weight
■■ Turn■■ Turn-tilt■■ Double casement■■ Tilt-first■■ Fanlight
■■ Uf until 1.2 W / (m2K)■■ Uw until 0.9 W / (m2K)■■ System tests according to
DIN EN 14351-1 for CE marking
■■ Burglar resistance in class WK1, WK2, WK3 and RC1, RC2, RC3
■■ Integration in stick system curtain walls
French window (window-door), barrier free
■■ Opening inward or outward■■ With barrier free threshold■■ Sash size until 1.70 x 2.50 m■■ Lockable
■■ Turn■■ Turn-tilt■■ Double casement■■ Tilt-first
■■ Uf until 1.3 W / (m2K)■■ Uw until 0.9 W / (m2K)■■ System tests according to
DIN EN 14351-1 for CE marking
Industry design
■■ Profile contours of classical steel window profiles
■■ Ideal for renovations■■ Profile depth 77 mm
■■ Turn■■ Turn-tilt■■ Double casement■■ Tilt-first■■ Fanlight
■■ System tests according to DIN EN 14351-1 for CE marking
■■ Burglar resistance in class WK1, WK2, WK3
Non-insulated
■■ Non-insulated profiles for interior application
■■ Profile depth 65 mm
■■ Turn■■ Turn-tilt■■ Double casement■■ Tilt-first■■ Fanlight■■ French window (window-door)
W I N D O W S
11
Name / series Main advantages Applications / opening types Performance features Special functions Section drawing
Classic design
■■ 30° bevelled profiles with overlapping sash
■■ Profile depth 75 / 85 mm■■ Fittings concealed or visible,
until 160 kg sash weight
■■ Turn■■ Turn-tilt■■ Double casement■■ Tilt-first■■ Fanlight
■■ Uf until 1.2 W / (m2K)■■ Uw until 0.9 W / (m2K)■■ System tests according to
DIN EN 14351-1 for CE marking
■■ Burglar resistance in class WK1, WK2, WK3 and RC1, RC2, RC3
■■ Integration in stick system curtain walls
French window (window-door), barrier free
■■ Opening inward or outward■■ With barrier free threshold■■ Sash size until 1.70 x 2.50 m■■ Lockable
■■ Turn■■ Turn-tilt■■ Double casement■■ Tilt-first
■■ Uf until 1.3 W / (m2K)■■ Uw until 0.9 W / (m2K)■■ System tests according to
DIN EN 14351-1 for CE marking
Industry design
■■ Profile contours of classical steel window profiles
■■ Ideal for renovations■■ Profile depth 77 mm
■■ Turn■■ Turn-tilt■■ Double casement■■ Tilt-first■■ Fanlight
■■ System tests according to DIN EN 14351-1 for CE marking
■■ Burglar resistance in class WK1, WK2, WK3
Non-insulated
■■ Non-insulated profiles for interior application
■■ Profile depth 65 mm
■■ Turn■■ Turn-tilt■■ Double casement■■ Tilt-first■■ Fanlight■■ French window (window-door)
Name / series Main advantages Applications / opening types Performance features Special functions Section drawing
Coupled window
■■ Coupled window with additional connected sash
■■ Improved thermal and sound insulation
■■ Profile depth 125 mm
■■ Turn■■ Turn-tilt
■■ Uw until 0.9 W / (m2K)■■ Sound insulation until
48 (-2 / -5) dB■■ System tests according to
DIN EN 14351-1 for CE marking
■■ Burglar resistance in class WK1, WK2, WK3
■■ Exterior sash can be with single or double glazing, concealed, with industry design or in SG structural glazing technology
■■ Sun protection device can be integrated between the sashes
Hybrid window
■■ Window with Hybrid technology■■ Double skin design with
2 sash types■■ Improved thermal and
acoustic insulation■■ Profile depth 215 mm■■ Optimized user comfort
■■ Interior sash: turn, turn-tilt
■■ Exterior sash: Parallel outward opening with motor operation
■■ Uw until 0.65 W / (m2K)■■ Sound insulation until 57 dB
■■ Sun protection device can be integrated between the sashes
■■ Automatic operation for night cooling
W I N D O W S
1312
D O O R S
Name / series Main advantages Applications / opening types Performance features Special functions Section drawing
■■ Basic series for individual adaptations according to the WICONA Unisys technology
■■ Profile depth 65 mm■■ Infill thickness 2 – 50 mm■■ Sash weight until 200 kg■■ Possible in Classic design with
30° bevelled profile contour
■■ Single and double leaf hinged door■■ Inward and outward opening■■ Push-pull door*■■ Finger protection door*■■ All-glass door*■■ Single action doors*■■ Fixed and movable lateral parts■■ Fanlight
■■ Uf until 1.8 W / (m2K)■■ Sound insulation until 43 dB■■ System tests according to
DIN EN 14351-1 for CE marking
■■ Burglar resistance in class WK1, WK2, WK3
■■ Integration in stick system curtain walls
■■ Panic function according to DIN EN 179 / 1125
■■ Leaf overlapping infill (single or double side) on demand
■■ Basic series for individual adaptations according to the WICONA Unisys technology
■■ Profile depth 75 mm■■ Infill thickness 3 – 60 mm■■ Sash weight until 200 kg■■ Possible in Classic design with
30° bevelled profile contour
■■ Single and double leaf hinged door
■■ Inward and outward opening■■ Push-pull door■■ Finger protection door■■ Push-pull doors■■ Fixed and movable lateral parts■■ Fanlight
■■ Uf until 1.6 W / (m2K)■■ Uw until below 0.8 W / (m2K)■■ Sound insulation until 43 dB■■ System tests according to
DIN EN 14351-1 for CE marking
■■ Burglar resistance in class WK1, WK2, WK3
■■ Integration in stick system curtain walls
■■ Leaf overlapping infill (single or double side) on demand
■■ Entrance door system with individual execution options
■■ Profile depth 88 mm
■■ Single and double leaf hinged door
■■ Inward and outward opening■■ Fixed and movable lateral parts■■ Fanlight
■■ Uf until 2.1 W / (m2K)■■ Sound insulation until 42 dB■■ System tests according to
DIN EN 14351-1 for CE marking
■■ Burglar resistance in class WK1, WK2, WK3
Non-insulated
■■ Non-insulated profiles for interior application
■■ Profile depth 50 mm
■■ Single and double leaf hinged door
■■ Inward and outward opening■■ Fixed and movable lateral parts■■ Fanlight
* In preparation
1312
D O O R S
Name / series Main advantages Applications / opening types Performance features Special functions Section drawing
■■ Basic series for individual adaptations according to the WICONA Unisys technology
■■ Profile depth 65 mm■■ Infill thickness 2 – 50 mm■■ Sash weight until 200 kg■■ Possible in Classic design with
30° bevelled profile contour
■■ Single and double leaf hinged door■■ Inward and outward opening■■ Push-pull door*■■ Finger protection door*■■ All-glass door*■■ Single action doors*■■ Fixed and movable lateral parts■■ Fanlight
■■ Uf until 1.8 W / (m2K)■■ Sound insulation until 43 dB■■ System tests according to
DIN EN 14351-1 for CE marking
■■ Burglar resistance in class WK1, WK2, WK3
■■ Integration in stick system curtain walls
■■ Panic function according to DIN EN 179 / 1125
■■ Leaf overlapping infill (single or double side) on demand
■■ Basic series for individual adaptations according to the WICONA Unisys technology
■■ Profile depth 75 mm■■ Infill thickness 3 – 60 mm■■ Sash weight until 200 kg■■ Possible in Classic design with
30° bevelled profile contour
■■ Single and double leaf hinged door
■■ Inward and outward opening■■ Push-pull door■■ Finger protection door■■ Push-pull doors■■ Fixed and movable lateral parts■■ Fanlight
■■ Uf until 1.6 W / (m2K)■■ Uw until below 0.8 W / (m2K)■■ Sound insulation until 43 dB■■ System tests according to
DIN EN 14351-1 for CE marking
■■ Burglar resistance in class WK1, WK2, WK3
■■ Integration in stick system curtain walls
■■ Leaf overlapping infill (single or double side) on demand
■■ Entrance door system with individual execution options
■■ Profile depth 88 mm
■■ Single and double leaf hinged door
■■ Inward and outward opening■■ Fixed and movable lateral parts■■ Fanlight
■■ Uf until 2.1 W / (m2K)■■ Sound insulation until 42 dB■■ System tests according to
DIN EN 14351-1 for CE marking
■■ Burglar resistance in class WK1, WK2, WK3
Non-insulated
■■ Non-insulated profiles for interior application
■■ Profile depth 50 mm
■■ Single and double leaf hinged door
■■ Inward and outward opening■■ Fixed and movable lateral parts■■ Fanlight
Name / series Main advantages Applications / opening types Performance features Special functions Section drawing
Non-insulated
■■ Non-insulated profiles for interior application
■■ Profile depth 65 mm
■■ Single and double leaf hinged door■■ Inward and outward opening■■ Fixed and movable lateral parts■■ Fanlight■■ Single action door■■ Finger protection door■■ All-glass door
■■ System tests according to DIN EN 14351-1 for CE marking
■■ Burglar resistance in class WK1, WK2
■■ Bullet resistance in class FB4■■ Panic function according to
DIN EN 179 / 1125■■ Smoke protection in
Class RS1, RS2
Fire protection door
■■ Fire protection door■■ Profile depth 77 mm
■■ Single and double leaf hinged door■■ Inward and outward opening■■ Fixed and movable lateral parts■■ Fanlight
■■ System tests according to DIN EN 14351-1 for CE marking
■■ Fire protection in class EI30 / T30 / F30
■■ With additional insertion strips in class EI60 / T60
■■ Panic function according to DIN EN 179 / 1125
■■ Smoke protection■■ Special functions depending
on national regulations
Fire protection door
■■ Fire protection system ready-to-install
■■ For interior application■■ Profile depth 100 mm
■■ Single and double leaf hinged door■■ Inward and outward opening
■■ Fire protection in class T90 / F90
Automatic sliding door
■■ Tested as complete system (with drive unit) according to DIN EN 14351-1
■■ Sash size until 2.0 x 3.0 m
■■ Single and double leaf sliding door■■ Fixed and movable lateral parts■■ Fanlight
■■ Ud until below 1.5 W/m2K■■ System tests according to
DIN EN 14351-1 for CE marking
■■ Multiple fittings and lock options
14
S L I D I N G S Y S T E M S
Name / series Main advantages Applications / opening types Performance features Special functions Section drawing
■■ Circumferential outer frame■■ Construction depth 160 mm
(double track)■■ Sash size until 3.24 x 3.4 m
■■ Lifting sliding door■■ Double track■■ Sliding or fixed sash
■■ Uw < 1.0 W / (m2K)■■ System tests according to
DIN EN 14351-1 for CE marking
■■ Integration in stick system constructions
■■ Construction depth 160 mm (double track) or 240 mm (triple track)
■■ Sash depth 60 mm■■ Sash size until 2.41 x 2.5 m
■■ Lifting sliding door / window, sliding door / window
■■ Double or triple track■■ Fixed sash■■ 2 to 6 leaves
■■ Uw < 1.3 W / (m2K)■■ System tests according to
DIN EN 14351-1 for CE marking
■■ Burglar resistance in class WK1, WK2
■■ Integration in stick system constructions
■■ Construction depth 105 mm (double track) or 160 mm (triple track)
■■ Sash depth 40 mm■■ Sash size until 2.1 x 2.45 m
■■ Lifting sliding door / window, sliding door / window
■■ Double or triple track■■ Fixed sash■■ 2 to 6 leaves
■■ Uw < 1.6 W / (m2K)■■ System tests according to
DIN EN 14351-1 for CE marking
■■ Burglar resistance in class WK1, WK2
■■ Integration in stick system constructions
■■ Construction depth 50 mm (double track) or 92 mm (triple track)
■■ Sash depth 34 mm
■■ Sliding door / window ■■ Double or triple track■■ Fixed sash■■ 2 to 6 leaves
15
S L I D I N G S Y S T E M S
Name / series Main advantages Applications / opening types Performance features Special functions Section drawing
■■ Non-insulated profiles for interior application
■■ Construction depth 50 mm (double track) or 92 mm (triple track)
■■ Sash 34 mm
■■ Sliding door / window ■■ Double or triple track■■ Fixed sash■■ 2 to 6 leaves
■■ Folding sliding system with partition to the right or to the left
■■ Inward and outward opening
■■ Folding sliding door■■ With single or double
casement sash■■ Turn or turn-tilt opening■■ 2 to 7 leaves
■■ Uw until 1.3 W / (m2K)■■ System tests according to
DIN EN 14351-1 for CE marking
■■ Low threshold for barrier free access
WICONA series
2510/01112120
T E C H N O L O G Y F O R I D E A S
Germany: Hydro Building Systems GmbHSöflinger Straße 70 D-89077 Ulm Phone +49 731 3984-0 Telefax +49 731 3984-241 www.wicona.de
Switzerland: Hydro Building Systems AGGewerbepark Postfach 30 CH-5506 Mägenwil Phone +41 62 88741-41 Telefax +41 62 88741-11 www.wicona.ch
Sweden: Hydro Building Systems ABBox 120 SE-360 70 Åseda Phone +46 474 48080 Telefax +46 474 10215 www.wicona.se
Norway: Hydro Building Systems ABDrammensveien 260 NO-0283 Oslo Phone +47 22 422200 Telefax +47 94 771222 www.wicona.no
Denmark: Salgskontor Danmark Hydro Building SystemsErhvervsparken 6 DK-8400 Ebeltoft Phone + 45 7020 2048 Telefax + 45 7020 2049 www.wicona.dk
Estonia / Latvia / Lithuania: Hydro Building Systems OÜPärnu mnt. 139 f EST-11317, Tallinn Phone +37 2657 6635 Telefax +37 2657 6602 www.wicona.com
Poland: Hydro Building Systems Sp. z o.o.ul. Mińska 63A PL - 03-828 Warszawa Phone +48 22 3308170 Telefax +48 22 3308171 www.wicona.com
Russia:ООО Гидро Билдинг СистемсRUS- 123317, Россия, Москва ул. Тестовская, д. 10 «Москва-Сити» БЦ «Северная башня» Тел. +7 917 5659559 www.wicona.ru
Austria: Hydro Building Systems GmbHWallerseestrasse 49 A-5201 Seekirchen Phone +43 (0) 6212 2000 Fax +43 (0) 6212 20236 www.wicona.at
Czech Republic: Hydro Building Systems spol. s r.o.Spielberk Office Centre Holandská 8 CZ-63900 Brno Phone +420 (0) 543 422030 Fax +420 (0) 543 250168 www.wicona.cz
Hungary: Hydro Building Systems Kft.Graphisoft Park, Záhony u 7 H-1031 Budapest Phone +36 (1) 4533457 Fax +36 (1) 4533459 www.wicona.at
Bulgaria:Hydro Building Systems EOOD“Bellissimo”, 102 Bulgaria Boulevard Et. 8, Ap. 10, P.O. Box 3 BG-1680 Sofia Phone +359 (2) 4903019 Fax +359 (2) 4903018 www.wicona.at
Slovenia: Hydro Building Systems GmbHKozjak nad Pesnico 34b SLO-2201 Zg. Kungota Phone +386 (0) 26 209970 Fax +386 (0) 26 209218 www.wicona.at
Serbia: Hydro Building Systems d.o.o.Bulevar Zorana Đindića 105/4 RS-11070 Novi Beograd Phone +381 (0) 11 3130695 Fax +381 (0) 11 3130695 www.wicona.at
Romania: Hydro Building Systems S.R.L.Str. Nerva Traian nr. 1 Bloc K6, sc.1, et.1, ap.2, sector 3 RO-031041 Bucuresti Phone +40 (0) 21 3260045 Fax +40 (0) 21 3264175 www.wicona.at
Croatia: Hydro Building Systems d.o.o.Ljudevita Posavskog 29 HR-10360 Sesvete Phone +385 (0) 12014800 Fax +385 (0) 12014801 www.wicona.at
WICONA is a Hydro brand