P600Vet Infusion Pump P600Vet Pumping mechanism Dimensions Weight Water proof classification Curvilinear peristaltic 174 x 126 x215 mm (W×D×H) approximately 2.5Kg IPX3 IV set selection IV set VTBI range 6 kinds of IV set data selectable and storable Compatible with other major brands, HANACO H-06APD IV set is recommended 0.1-9999ml 0.1 ~ 1500ml/h (0.1ml/h increments) 1-20ml/h(1ml increments) 100-1500 ml/h(0.1 ml increments) Flow rate Purge rate Drop/min Time-based Easy mode 0.1-5ml/h(0.1ml/h increments) Infused volume Pressure release automatically when pump get preset occlusion value IInfusion mode KVO rate Anti-bolus 9 kinds: Occlusion, air-in-line, Pump door open, infusion completion, low battery, drop rate abnormal, flow rate abnormal, KVO, unattended Occlusion Sensitivity ≤40μL, Ultrasonic detector Audial and visual alarm Power supply(AC) 220±22/110V(optional), 50/60Hz Battery(DC) 9.6±1.6V, Ni-MH, rechargeable Battery /operation/charging Ni-MH/ 5 hours (at 30ml/h) / more than 8 hours Power consumption ≤20VA Safety classification Class II, Type CF Operation temperature Working relative humidity Atmospheric pressure Storage temperature Storage relative humidity 10~4030~75% (no condensation) 700-1060 hpa -20~+50≤93% RH (no condensation) Built-in thermostat 30-45adjustable Standard configured consumables Comprehensive system management with other medical equipment by wireless connection Packed with pump 1 set IV set Optional IV pole Infusion accuracy ±3% ml/h 3 levels: High/ Medium/ Low Sensitivity of air in line P500-1805-1 Guangdong Biolight Meditech co., Ltd. Add: NO.2 Innovation First Road, Technical Innovation Coast, Hi-tech Zone, Zhuhai, P. R. China, Postcode: 519085 Tel: +86-756-3399935 Fax: +86-756-3399911 E-Mail: [email protected] www.blt.com.cn Mechanical Parameter IV set & Accuracy Alarms Power & Environment Extended function Wireless management(optional) Technical Specifications

Transcript of Veterinary Infusion Pump - Veterinary Equipment & Servicing

Page 1: Veterinary Infusion Pump - Veterinary Equipment & Servicing

P600Vet Infusion PumpP600Vet

Pumping mechanismDimensionsWeightWater proof classification

Curvilinear peristaltic174 x 126 x215 mm (W×D×H)approximately 2.5KgIPX3

IV set selectionIV setVTBI range

6 kinds of IV set data selectable and storableCompatible with other major brands, HANACO H-06APD IV set is recommended0.1-9999ml0.1 ~ 1500ml/h (0.1ml/h increments)

1-20ml/h(1ml increments)100-1500 ml/h(0.1 ml increments)

Flow ratePurge rate

Drop/minTime-basedEasy mode0.1-5ml/h(0.1ml/h increments)

Infused volume

Pressure release automatically when pump get preset occlusion value

IInfusion mode

KVO rateAnti-bolus

9 kinds: Occlusion, air-in-line, Pump door open, infusion completion, low battery, drop rate abnormal, flow rate abnormal, KVO, unattended

Occlusion Sensitivity

≤40μL, Ultrasonic detector

Audial and visual alarm

Power supply(AC) 220±22/110V(optional), 50/60HzBattery(DC) 9.6±1.6V, Ni-MH, rechargeableBattery /operation/charging Ni-MH/ 5 hours (at 30ml/h) / more than 8 hoursPower consumption ≤20VASafety classification Class II, Type CFOperation temperatureWorking relative humidityAtmospheric pressureStorage temperatureStorage relative humidity

10~40℃ 30~75% (no condensation)700-1060 hpa-20~+50℃≤93% RH (no condensation)

Built-in thermostat 30-45℃ adjustable

Standard configured consumablesComprehensive system management with other medical equipment by wireless connection

Packed with pump 1 set IV setOptional IV pole

Infusion accuracy ±3% ml/h

3 levels: High/ Medium/ Low

Sensitivity of air in line

P500-1805-1Guangdong Biolight Meditech co., Ltd. Add: NO.2 Innovation First Road, Technical Innovation Coast, Hi-tech Zone, Zhuhai, P. R. China, Postcode: 519085Tel: +86-756-3399935 Fax: +86-756-3399911 E-Mail: [email protected] www.blt.com.cn

Mechanical Parameter

IV set & Accuracy

Alarms

Power & Environment

Extended function

Wireless management(optional)

Technical Specifications

Page 2: Veterinary Infusion Pump - Veterinary Equipment & Servicing

Double infusion mode: volumetric and drop rate

Anti-bolus

Automatically switch to KVO speed operation upon preset goal is completed

Rechargeable Ni-MH battery 30ml at 5 hours

Memory of last operation setting parameters

Extensive injection rate range, from 0.1ml/h to 1500ml/h, 0.1ml increments

9 kinds audio-visual alarm insure safety

Automatically switch among drop/min, time-based and ml/h

Change flow rate without stopping the pump

Key locker

Abnormal infusion flow rate audial prompt function guarantee error free operation

Fuse

Double fuse design with

back-up fuse (0.25AL 205V)

Sensitive air bubble detector

Built-in thermostat

30-45℃ adjustable

Pressure sensor

Specially designed to sensitively detect occlusion

Pressure in I.V. set

Handle

DECR and SET key

Change mode easily

Pump door

Durable metal design avoid breakage

Anti-slip plastic feet

4.2” high definition LCD color screen

Audio-visual alarm

Easy to recognize alarm types