TSC measurements on n- and p-type MCz silicon diodes after irradiation

22
TSC measurements on n- and p-type MCz silicon diodes after irradiation with neutrons up to 10 15 -10 16 n/cm 2 M. Bruzzi, D. Menichelli, R. Mori, M. Scaringella INFN Firenze, Dip. Energetica “S. Stecco”, Via S. Marta 3 50139 Firenze Italy

description

TSC measurements on n- and p-type MCz silicon diodes after irradiation with neutrons up to 10 15 -10 16 n/cm 2 M. Bruzzi, D. Menichelli, R. Mori, M. Scaringella INFN Firenze, Dip. Energetica “S. Stecco”, Via S. Marta 3 50139 Firenze Italy. Samples and irradiation. - PowerPoint PPT Presentation

Transcript of TSC measurements on n- and p-type MCz silicon diodes after irradiation

Page 1: TSC measurements on n- and p-type MCz silicon diodes after irradiation

TSC measurements on n- and p-type MCz silicon diodes after irradiation

with neutrons up to 1015-1016 n/cm2

M. Bruzzi, D. Menichelli, R. Mori, M. ScaringellaINFN Firenze, Dip. Energetica “S. Stecco”, Via S. Marta 3 50139 Firenze Italy

Page 2: TSC measurements on n- and p-type MCz silicon diodes after irradiation

Samples and irradiation

-Material:n-type magnetic Czochralski silicon produced by Okmetic (Finland) with 900 cm resistivity, <100> orientation and 280m thickness. -Devices: p-on-on planar diodes 0.5x0.5cm2

-Procurement: WODEAN, Thanks to E. Fretwurst, G. Lindstroem-Irradiation: reactor neutrons at the Jozef Stefan Institute, Ljubljana-fluence: 1013-1014-1015 neq/cm2 1MeV equivalent neutron -Annealing: 1 year room temperature

-Material: p-type magnetic Czochralski silicon produced by Okmetic (Finland) with 2k cm resistivity, <100> orientation and 280m thickness-devices: n-on-op square diodes 0.5x0.5cm2

-Procurement: SMART, Thanks to D. Creanza, N. Pacifico-Irradiation: reactor neutrons at the Jozef Stefan Institute, Ljubljana-fluence: 1014-1016 1/cm2 1MeV equivalent neutron -Annealing: few days room temperature (+ 80min 80°C)

Page 3: TSC measurements on n- and p-type MCz silicon diodes after irradiation

Measurement Techniques

1. Thermally Stimulated Currents with cryogenic equipments: measurements performed on Liquid He vapors, to ensure stable temperatures down to 4.2K minimize thermal inertia and mismatch.

(a) To evidence presence of shallow donors/acceptors(b) To study annealing effects ( 80min 80°C )

2. Zero Bias Thermally Stimulated Currents measured at high fluence in the high temperature range (100-200K),

(a) to avoid background current subtraction, and increase resolution in deep levels analysis.

(b) To get information about electric field distribution

Page 4: TSC measurements on n- and p-type MCz silicon diodes after irradiation

[SD]MCz/[SD]FZ > 5

MCz n-type MeV p irradiated, =4×1014 cm-2

[D. Menichelli, RD50 Workshop, Nov..2005]

• 2005: Shallow donor generated by 24GeV proton irradiation in MCz (4x1014p/cm2)

[M. Bruzzi, Trento Workshop, Feb. 2005]

MCz n-type and p-type 24 GeV p irradiated, =4×1014 cm-2

M. Scaringella et al. NIM A 570 (2007) 322–329

Comparison between p- and n-type MCz Si in low T reveals presence of same shallow peak at 30K.

1. (a) Low Temperature measurements - Standard TSC analysis

Page 5: TSC measurements on n- and p-type MCz silicon diodes after irradiation

25 30 35 400

0.2

0.4

0.6

0.8

1

1.2

1.4

x 10-10

temperature [K]

curr

ent

[A]

Vrev=100V

Vrev=200VVrev=350V

25 30 35 400

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

x 10-10

temperature [K]

curr

ent

[A]

Vrev=100V

Vrev=200V

n- and p-MCz Si 24 GeV p irradiated 4x1014cm-2 ( =2.5*1014 neq/cm2)

n on p p on n

30 K peak - PF shift evidences its charged nature in n-type.No P-F shift observed in p-type MCz Si irradiated with same fluence.

Evidence of Poole Frenkelno Poole Frenkel

Page 6: TSC measurements on n- and p-type MCz silicon diodes after irradiation

20 30 40 50 60 70 80

10-13

10-12

10-11

10-10

temperature [K]

curr

ent

[A]

d32, TSC

Vrev=10V

Vrev=100V

Vrev=200V

=1014n/cm2

N-on-p MCz SiNo annealing

p-type MCz Si after neutron irradiation. Different reverse voltages (10-300V) to evidence Pool Frenkel effects and thus visualize the existence of charged defects. Confirmed that peak at 30K has no appreciable Poole Frenkel shift.

2009 measurements

Page 7: TSC measurements on n- and p-type MCz silicon diodes after irradiation

Only peak at 25K is observed to shift in temperature, but this peak always present (in irradiated and non-irradiated samples, independent of material type and kind, irradiation fluence and annealing time up to 110 min at 150 ◦C).

D.MENICHELLI et al. Appl. Phys. A 84, 449–453 (2006)

P-F on D(25K) peak

Page 8: TSC measurements on n- and p-type MCz silicon diodes after irradiation

2. (b) Annealing studies: Standard TSC

Up to now the study has been performed on p-type MCz Si

Irradiated with reactor neutrons up to = 1015n/cm2

Annealing: 80min 80°C

Measurements carried out: Standard TSC

-Peaks studied for temperatures up to 170K because at higher T too low resolution due to background current subtraction

Page 9: TSC measurements on n- and p-type MCz silicon diodes after irradiation

60 80 100 120 140 160 180 2000

0.5

1

1.5

2

2.5

3

x 10-10

temperature [K]

curr

ent

[A]

before annealing

annealed 80 min @80°C

60 80 100 120 140 160 180 2000

0.5

1

1.5

2

2.5

3

x 10-10

temperature [K]

curr

ent

[A]

before annealing

annealed 80 min @80°C

Ea (eV) (cm2) type

0.36 1.2x10-15 H(Pintilie)

0.36 2.5x10-15 H (CiOi)

0.41 1x10-15 E (V2)

0.42 23x10-15 H(Pintilie)

We evidence an increase of peak components at 140K and 150K, as found in MCz material n-type, (1MeVn)= 5x1013cm-2 (I.Pintilie et al. Appl. Phys. Lett. 92, 024101 2008)

F=1015n/cm2

n-on-p MCz SiFit before ann.

F=1015n/cm2

n-on-p MCz SiFit after ann.

Page 10: TSC measurements on n- and p-type MCz silicon diodes after irradiation

1. Priming provide an injection of carriers which are trapped at energy levels, according to an asymmetrical distribution induced by external polarization (Vrev).

2. At low temperature electrodes are short-circuited: the carriers at electrodes and in bulk redistribute themselves in order to establish zero voltage and zero field boundary conditions. Charge frozen at low temperature → non-uniform electric field and non-monotonous potential distribution with minima and maxima corresponding to zero electric-field planes settle.

ZBTSC: Method and Experimental procedure

3. ZBTSC scan (heating): system brought back to the fundamental equilibrium state. Charge redistribute into the volume and charge injection occurs at the electrodes, giving rise to current detected in the external circuit. Charge relaxation during heating scan can be discussed in terms of motion of the zero electric-field planes along the sample thickness.

Example: double junction in irradiated p-on-n Si ( Voltages measured at n+ respect to p+). Charge distribution not shown.

A

D

n+p+

Fp

Fn

eVrevNeff > 0

Neff < 0

Zero-field planes

A

D

p+

Fp=Fn

n+

0dxdV

Page 11: TSC measurements on n- and p-type MCz silicon diodes after irradiation

TSC ZB-TSC

TSCSample reverse-biased: electric field always with same sign. As a consequence, emitted electrons and holes, regardless of the region from which they are emitted, produce always a positive current.

Electric field changes sign inside the bulk. Traps emitting close to p+ or n+ interfaces give rise to a positive current; those emitting in the bulk will produce a negative current. These two contributions, whose intensity is related to electric field rearrangement during emission, are summed up in the overall measured current. Current sign depends on which components dominate.

Why negative currents?

Example: double junction in irradiated p-on-n Si (Voltages measured at n+ respect to p+, currents positive when flowing from n+ to p+) ; X hole trap Y electron trap.

Page 12: TSC measurements on n- and p-type MCz silicon diodes after irradiation

Advantages of ZB-TSC

1. Better resolution and reliability in detecting deep traps. In a standard TSC, deep level emissions can be analyzed as long as they are clearly distinguishable from the background current irev. This becomes a problem with heavily irradiated silicon. In fact irev increases linearly with fluence and exponentially with temperature.

In our n-on-p samples:

1013n/cm2 Tmax ~ 195K 1014n/cm2 Tmax ~ 185K 1015n/cm2 Tmax ~ 150K

Deep levels with activation energies close to midgap, important because are believed to be related to extended defects, give TSC signal in the range 180-220K → No reliable evidence for such defects, usually with energies >0.4eV, at high fluences.

Page 13: TSC measurements on n- and p-type MCz silicon diodes after irradiation

50 100 150 200 250 3001E-14

1E-13

1E-12

1E-11

1E-10

1E-9

1E-8

1E-7

1E-6

1E-5

1E-4

1E-3

n-on-p

f=1015 n/cm2

annealing 80 min 80°C

TSC ZBTSC Background

Abs

olut

e C

urre

nt [

A]

Temperature [K]

In ZBTSC background current is heavily suppressed and a wider temperature range can be explored.

-5.E-10

-3.E-10

-1.E-10

1.E-10

3.E-10

5.E-10

7.E-10

9.E-10

100 120 140 160 180 200 220

Temperature [K]

Cu

rre

nt

[A]

subtracted

TSC

BackgroundCumbersome subtractions of background current from TSC produces big uncertainties and can give rise to artifacts.

Advantages of ZB-TSC

Page 14: TSC measurements on n- and p-type MCz silicon diodes after irradiation

160 180 2000.0

0.2

0.4

0.6

0.8

1.0

1.2

rela

tive

ZB

TS

C

Temperature [K]

n-on-p no annealing

f =1015 neq

/cm2

f =1016 neq

/cm2

N-on-p MCz Si diodeNo annealing

p-on-n MCz Si diode1 year at Room Temperature

As ZB-TSC cannot give trap concentration, we compare directly the relative signals.

Preliminary measurements: Comparison with different fluences, same material, similar annealing

160 180 200 2200.0

0.2

0.4

0.6

0.8

1.0

1.2

rela

tive

ZB

TS

C

Temperature [K]

p-on-n 1 year RT annealing

1e14 neq

/cm2

1e15 neq

/cm2

Tendency to increase the high T part of the spectrum rising the fluence

Page 15: TSC measurements on n- and p-type MCz silicon diodes after irradiation

Preliminary: analysis on ZBTSC n-on-p MCz Sifluence = 1015 and 1016 n/cm2

140 160 180 2000

5

10

15

20f=1015 n/cm2

n-on-p MCz Si

E=[0.427 0.500 ] eV

s=[0.1 4]*1e-15 cm2

Amp=[12 5 ] pA;

Y A

xis

Titl

e

X Axis Title

exp fit peak 1 peak 2

160 180 2000

1

2

3

4

5

E=[0.427 0.508 ] eV

s=[0.1 4 ]*1e-15 cm2

Amp=[1.95 2.25 ] pA;

f=1016 n/cm2

n-on-p MCz Si

Cur

rent

[pA

]Temperature [K]

exp fit peak 1 peak 2

-Two components:-Tmax= 170K;176K; -Et ~ 0.4;0.5eVDeepest level increases relative amplitude with fluence.

Results must be confirmed with more investigations on priming procedure and electric field structure evaluation during measurements.

Page 16: TSC measurements on n- and p-type MCz silicon diodes after irradiation

-Three components in the high T range (T>160K): -Tmax=170K, 176K,185K , Et = 0.4-0.5eV

120 130 140 150 160 170 180 190 2000

10

20

30

40

50p-on-n MCz Si

f=1015 n/cm2

1 year self annealing

Cur

rent

[pA

]Temperature [K]

exp fit 185K 176K 170K 152K 144K

140 160 180 2000

5

10

15

20

p-on-n MCz Si

f = 1014 n/cm2

Cur

rent

[pA

]

Temperature [K]

exp 185K 176K 170K 152K 144K

Preliminary: analysis on ZBTSC p-on-n MCz Sifluence = 1014 and 1015 n/cm2

Results must be confirmed with more investigations on priming procedure and electric field structure evaluation during measurements.

Page 17: TSC measurements on n- and p-type MCz silicon diodes after irradiation

We performed an evaluation of radiation-induced defects in p- and n-type MCz Si after irradiation with reactor neutrons up to 1015-1016cm-2.

-Low Temperature TSC was carried out to inspect shallow defects. No Poole Frenkel effect on 30K-peak in p-type MCz. Shallow peak at 30K does not contribute to space charge in p-type?

-After 1015n/cm2 irradiation and annealing of 80min at 80°C two peaks at H(140K) and H(150K) increase amplitude in p-type MCz Si. Same effect as in n-type MCz (observed for lower fluence by Pintilie et al.).

-Defects analyses carried out up to 1015-1016cm-2 with ZB-TSC, to avoid background current. Preliminary analysis comparing relative amplitudes as a function of fluence and conductivity type: (a) increase of the high T components increasing the fuence (b) presence of one more component peak in n-type at higher T with respect to p-type. Results must be confirmed with more investigations on priming procedure and electric field structure evaluation during measurements.

Summary

Page 18: TSC measurements on n- and p-type MCz silicon diodes after irradiation

spares

Page 19: TSC measurements on n- and p-type MCz silicon diodes after irradiation

Electric field contributions in ZBTSC:

a) built-in at electrodes; b) intrinsic at traps ionized in the bulk; c) offset due to faible potential differences remaining at electrodes

during short-circuit. d) Intentional offset applied to counteract or support emission (quasi-

ZBTSC).

Best conditions to observe trap emission must be determined experimentally, by evaluating these components and evaluate their effect on trap emission.

Page 20: TSC measurements on n- and p-type MCz silicon diodes after irradiation

Typically, but non-necessarily, the ZBTSC will flow in the opposite direction of the current that has established the charge distribution during the priming, but the initial direction can be reversed during the thermal scan.

100 125 150 175 200 225-20

-10

0

10

20

30

40 TSC V=-100V ZBTSC (x15) V=0

p-on-n SMW46Vcool=-100V, Vfill=+100V

Cur

rent

[pA

]

Temperature [K]

Here signal due to trap emission change sign when changing from TSC to ZBTSC, while current background, due to offset voltage, is always positive.

Page 21: TSC measurements on n- and p-type MCz silicon diodes after irradiation

Offset effect on current

100 125 150 175 200 225 250 275

-10

0

10

20

30

40

MCz Si

I [p

A]

Temperature [K]

n-on-p 1e15 n/cm2 n-on-p 1e16 n/cm2 p-on-n 1e14 n/cm2 p-on-n 1e15 n/cm2150 175 200

-10

0

10

20

30

40

MCz Si

I [p

A]

Temperature [K]

n-on-p 1e15 n/cm2 n-on-p 1e16 n/cm2 p-on-n 1e14 n/cm2 p-on-n 1e15 n/cm2

Page 22: TSC measurements on n- and p-type MCz silicon diodes after irradiation

n-on-p irradiated Si

ZB-TSC measurements performed at different fluences. Thick lines indicate measurements carried out in the following reference conditions: V=Vcool=100V during the cooling from room temperature to T0, V=Vfill=-100V to inject carriers at T0.

At the lowest fluence a positive signal is observed in the range 130-160K. At the intermediate fluence the signal extends up to 190K and its zero-crossings reveal the presence of regions with opposite electric field. At the highest fluence the spectrum is completely dominated by negative components from the bulk.

2. Inspection of intrinsic electric field due to charged defects