trauoml

176
s Outputs Transcoding and Rate Adaption Unit OML:TRAU A30808-X3247-M440-1-7619

Transcript of trauoml

Page 1: trauoml

s

Outputs Transcoding and Rate Adaption Unit

OML:TRAU

A30808-X3247-M440-1-7619

Page 2: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

2 A30808-X3247-M440-1-7619

© Copyright Siemens Mobile Communications S.p.A. 2005

Technical modifications possible. Technical specifications and features are binding only insofar as they are specifically and expressly agreed upon in a written contract.

Page 3: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 3

This document consists of a total of 176 pages. Insert the document in binder: OML:TRAU Reason for Update Chapter/Section Reason for Update 4.1.6 FEKAT DE2667

Issue History Issue Number

Date of Issue

Reason for Update

4 11/2005 New Edition for Release BR8.0

Page 4: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

4 A30808-X3247-M440-1-7619

Page 5: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 5

1 Contents

1 Contents ...................................................................................................................................................5 2 Introduction...............................................................................................................................................9 3 GSM Probable Causes...........................................................................................................................15

3.1 Equipment Failure ..........................................................................................................................15 3.1.1 1006 - PLL_FAILURE .............................................................................................................15 3.1.2 1007 - BSCI_HW_FAULT .......................................................................................................16 3.1.3 1009 - TRAC_TIMING_LOSS.................................................................................................20 3.1.4 1012 - PROTECTED_MEMORY_ILLEGAL_WRITE_ATTEMPT ...........................................21 3.1.5 1020 - PCMS_CIRCUIT_ALARM............................................................................................22 3.1.6 1021 - PCMA_CIRCUIT_ALARM............................................................................................24 3.1.7 1042 - BSMS_DIAGNOSTIC_FAILURE .................................................................................26 3.1.8 1045 - TRAC_DIAGNOSTIC_FAILURE .................................................................................27 3.1.9 1047 - TRAC_DIAGNOSTIC_ONLINE_FAILURE..................................................................28 3.1.10 1052 - TPWR_DIAGNOSTIC_FAILURE.................................................................................30 3.1.11 1059 - MSCI_HW_FAULT.......................................................................................................31 3.1.12 1074 - TPWR_FAULT .............................................................................................................32 3.1.13 1077 - TRAC_HW_FAULT......................................................................................................33 3.1.14 1078 - MSCI_SYNC_8KHZ_FAILED ......................................................................................34 3.1.15 1079 - MSCI_DIGA_FAULTED...............................................................................................35 3.1.16 1081 - TRAC_FAIL_TO_LOAD...............................................................................................36 3.1.17 1082 - FLASH_EPROM_NOT_VALID ....................................................................................37 3.1.18 1086 - TRAC_LINK_FAILURE................................................................................................39 3.1.19 1088 - TRAC_CARD_FAILURE..............................................................................................40 3.1.20 1089 - DSP_FAIL_TO_LOAD .................................................................................................41 3.1.21 1100 - BSCI_CARD_FAILURE ...............................................................................................42 3.1.22 1104 - BSCI_KEEP_ALIVE_ALARM ......................................................................................43 3.1.23 1105 - MSCI_KEEP_ALIVE_ALARM......................................................................................44 3.1.24 1106 - INCONSISTENT_STATUS..........................................................................................45

3.2 Line Interface Failure......................................................................................................................46 3.2.1 11 - LOSS_OF_SIGNAL .........................................................................................................46 3.2.2 12 - AIS_ALARM.....................................................................................................................48 3.2.3 18 - LOSS_OF_SIGNAL_ON_LINK_A ...................................................................................50 3.2.4 19 - LOSS_OF_SIGNAL_ON_LINK_B ...................................................................................52 3.2.5 20 - AIS_ALARM_ON_LINK_A...............................................................................................54 3.2.6 21 - AIS_ALARM_ON_LINK_B...............................................................................................56

3.3 Loss of Synchronisation .................................................................................................................58 3.3.1 1097 - BAD_PLL_INPUT_SYNCHRONISATION ...................................................................58

3.4 Database Inconsistency .................................................................................................................59 3.4.1 1019 - INVALID_DATABASE_WARNING ..............................................................................59 3.4.2 1023 - TRAC_DBA_REFUSED...............................................................................................60 3.4.3 1091 - DATABASE_INCONSISTENCY_BRINGUP................................................................61 3.4.4 1102 - PROBABLE_DATABASE_INCONSISTENCY.............................................................62

3.5 Input Parameter out of Range ........................................................................................................63 3.5.1 1015 - INPUT_PARAMETER_OUT_OF_RANGE_WARNING...............................................63

3.6 Invalid Pointer .................................................................................................................................64 3.6.1 1114 - INVALID_POINTER_WARNING .................................................................................64

3.7 Message not Expected...................................................................................................................65 3.7.1 1014 - UNEXPECTED_MESSAGE.........................................................................................65 3.7.2 1044 - INVALID_MESSAGE_DATA........................................................................................66 3.7.3 1048 - INVALID_RTE_HEADER_FIELD_VALUE...................................................................67 3.7.4 1060 - MSCI_SW_ERROR .....................................................................................................68 3.7.5 1080 - TRAC_UNEXPECTED_MESSAGE.............................................................................69

3.8 Message Out of Sequence.............................................................................................................70

Page 6: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

6 A30808-X3247-M440-1-7619

3.8.1 1033 - MESSAGE_OUT_OF_SEQUENCE_WARNING.........................................................70 3.9 System Call Unsuccessful ..............................................................................................................72

3.9.1 1024 - SYSTEM_CALL_UNSUCCESSFUL_WARNING........................................................72 3.9.2 1028 - FUNCTION_CALL_UNSUCCESSFUL........................................................................74 3.9.3 1066 - MESSAGE_NOT_SENT..............................................................................................77 3.9.4 1067 - INVALID_DB_CALL .....................................................................................................79 3.9.5 1096 - SYSTEM_CALL_UNSUCCESSFUL_MINOR .............................................................80

3.10 Timeout Expired .............................................................................................................................81 3.10.1 1037 - TIMEOUT_EXPIRED_WARNING ...............................................................................81 3.10.2 1075 - TRAC_KEEP_ALIVE_ALARM.....................................................................................85 3.10.3 1087 - DSP_TSYNC_EXPIRED..............................................................................................86 3.10.4 1090 - DSP_KEEP_ALIVE_ALARM .......................................................................................87

3.11 Variable Out of Range....................................................................................................................91 3.11.1 1029 - VARIABLE_OUT_OF_RANGE....................................................................................91

3.12 Watch Dog Timer Expired ..............................................................................................................92 3.12.1 1003 - TRAC_WDT_TIMEOUT...............................................................................................92 3.12.2 1004 - BSCI_WDT_TIMEOUT ................................................................................................93 3.12.3 1005 - BSCI_WDT_WARNING...............................................................................................94

3.13 FAN Failure ....................................................................................................................................95 3.13.1 5002 - FAN_ALARM................................................................................................................95

3.14 System Resources Overload..........................................................................................................96 3.14.1 1115 - UNABLE_TO_RUN_TEST...........................................................................................96

3.15 LAPD Link Protocol Failure ............................................................................................................97 3.15.1 2001 - ASUB_TRANSIENT_FAILURE ...................................................................................97 3.15.2 2003 - LPDL_LINK_DOWN.....................................................................................................98

3.16 Remote alarm indication.................................................................................................................99 3.16.1 15 - REMOTE_ALARM ...........................................................................................................99 3.16.2 26 - REMOTE_ALARM_ON_LINK_A ...................................................................................101 3.16.3 27 - REMOTE_ALARM_ON_LINK_B ...................................................................................103

3.17 Transmission Error .......................................................................................................................105 3.17.1 16 - HIGHER_BER_THRESHOLD_EXCEEDED .................................................................105 3.17.2 17 - LOWER_BER_THRESHOLD_EXCEEDED ..................................................................107 3.17.3 28 - HIGHER_BER_THRESHOLD_EXCEEDED_ON_LINK_A ...........................................109 3.17.4 29 - HIGHER_BER_THRESHOLD_EXCEEDED_ON_LINK_B ...........................................111 3.17.5 30 - LOWER_BER_THRESHOLD_EXCEEDED_ON_LINK_A ............................................113 3.17.6 31 - LOWER_BER_THRESHOLD_EXCEEDED_ON_LINK_B ............................................115

4 ITU Probable Causes ...........................................................................................................................117 4.1 Configuration Or Customization Error ..........................................................................................117

4.1.1 1010 - HW_NOT_COMPATIBLE_WITH_INTERNAL_POWER ...........................................117 4.1.2 1032 - TRAC_HW_NOT_COMPATIBLE_WITH_ACTUAL_CONFIGURATION ..................118 4.1.3 1036 - BSCI_HW_VERSION_NOT_VALID_FOR_PCM_TYPE...........................................119 4.1.4 1038 - MSCI_HW_VERSION_NOT_VALID_FOR_PCM_TYPE ..........................................120 4.1.5 1103 - TPWR_OFFREQUEST_PENDING ...........................................................................121 4.1.6 1116 - TRAC_HW_NOT_COMPATIBLE_WITH_VQE .........................................................122 4.1.7 2002 - UNEXPECTED_TEI...................................................................................................123

4.2 Congestion ...................................................................................................................................124 4.2.1 1098 - T_INTERFACE_MESSAGE_LOST ...........................................................................124

4.3 Corrupt Data .................................................................................................................................125 4.3.1 1083 - FLASH_EPROM_MUST_BE_FORMATTED.............................................................125 4.3.2 1108 - FORMATTING_FLASH_EPROM ..............................................................................127 4.3.3 1109 - INVALID_FILE_FORMAT ..........................................................................................128

4.4 Enclosure Door Open...................................................................................................................130 4.4.1 5001 - OPEN_DOOR_ALARM..............................................................................................130

4.5 Loss Of Frame..............................................................................................................................131 4.5.1 13 - LOSS_OF_FRAME_ALIGNMENT.................................................................................131 4.5.2 14 - LOSS_OF_CRC_ALIGNMENT .....................................................................................133 4.5.3 22 - LOSS_OF_FRAME_ALIGNMENT_ON_LINK_A...........................................................135

Page 7: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 7

4.5.4 23 - LOSS_OF_FRAME_ALIGNMENT_ON_LINK_B...........................................................136 4.5.5 24 - LOSS_OF_CRC_ALIGNMENT_ON_LINK_A ...............................................................137 4.5.6 25 - LOSS_OF_CRC_ALIGNMENT_ON_LINK_B ...............................................................138

4.6 Out Of Memory .............................................................................................................................139 4.6.1 1040 - MEMORY_NOT_AVAILABLE....................................................................................139 4.6.2 1041 - MAILBOX_CANNOT_BE_CREATED........................................................................140 4.6.3 1093 - EMPTY_RTE_POOL_RESTART ..............................................................................141 4.6.4 1094 - EMPTY_MESSAGE_POOL.......................................................................................142 4.6.5 1113 - MEMORY_OVERFLOW ............................................................................................143

4.7 Software Error ..............................................................................................................................144 4.7.1 1016 - AR_PROCEDURAL_ERROR....................................................................................144 4.7.2 1017 - RTE_INTERRUPT_LOOP .........................................................................................145 4.7.3 1018 - STANDBY_ALIGNMENT_FAILED ............................................................................146 4.7.4 1034 - SCHEDULER_BLOCKED..........................................................................................147 4.7.5 1035 - INITIALIZATION_UPDATED .....................................................................................148 4.7.6 1043 - INITIALIZATION_FAILURE .......................................................................................149 4.7.7 1046 - FILE_SYSTEM_ERROR............................................................................................151 4.7.8 1049 - INTERNAL_LINK_FAILURE......................................................................................154 4.7.9 1053 - BSMS_PROCEDURAL_ERROR...............................................................................155 4.7.10 1068 - TIMER_CANNOT_BE_SET.......................................................................................156 4.7.11 1084 - STANDBY_NOT_ALIGNED.......................................................................................158 4.7.12 1099 - RTE_AUDIT_ERROR................................................................................................159 4.7.13 1107 - BSCI_RESET_CAUSE ..............................................................................................160 4.7.14 1110 - PERIPHERAL_LOADING_ERROR...........................................................................162

4.8 Software Program Abnormally Terminated ..................................................................................163 4.8.1 1111 - DELETED_CURRENT_TASK ...................................................................................163 4.8.2 1112 - DELETED_CURRENT_INIT_FUNCTION .................................................................164

5 Index of Specific Problems...................................................................................................................165 6 ANNEX A..............................................................................................................................................169 7 ANNEX B..............................................................................................................................................173 8 ANNEX C..............................................................................................................................................175

Page 8: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

8 A30808-X3247-M440-1-7619

Page 9: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 9

2 Introduction This manual contains the description of all errors that the SBS/TRAU system can generate. An example of one error printout from Local Terminal is shown in Figure 1. This output manual is just a listing of all possible system messages. Output manuals can not substitute or replace maintenance manuals and are only intended for the support of experienced personnel when performing specialized fault clearance tasks.

JOB: 11 PC Time&Date: 11:05:49 01/22/2001 NE Time&Date: 11:29:31 22/01/2001 USER: LMT User SW RELEASE: 02-06-01-01-03-00_01-01-19 COMMAND RESULT: Successful FAILURE EVENT REPORT: NAME = TRAC:2 Event Type = Equipment Failure Event Event Time = 22/Jan/2001 11:29:31 Probable Cause = Equipment Failure Specific Problems = 1088 - TRAC Card Failure Severity = Minor Notification Identifier = 29 Proposed Repair Actions = 13 - Insert and test the addressed card Originator = 27 Additional Words = H'0701 H'0003 H'0000 H'0000 H'0002 H'0002 H'ffff H'ffff H'ffff H'ffff H'ffff H'ffff H'ffff H'ffff H'ffff Software Version = 02-06-01-01-03-00_01-01-19 END OF OUTPUT FOR JOB 11

Figure 1

Every fault occurrence from Local Terminal is related, at least, to one page of error description in this manual. This manual is organized according to the PROBABLE CAUSE. Failure Events are grouped by Probable Cause. For every Probable Cause, different failure events are reported according to the Specific Problem field. In Annex A, for every TRAU Specific Problem, the associated Probable Cause is provided.

Page 10: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

10 A30808-X3247-M440-1-7619

So, by taking into account these two elements the operator can determine the page of the error manual where the Failure Event being analyzed is described. 1045 - TRAC_DIAGNOSTIC_FAILURE FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: EQUIPMENT FAILURE EVENT Probable Cause: EQUIPMENT FAILURE Specific Problems: TRAC_DIAGNOSTIC_FAILURE Severity: <OPERATOR DEFINED> default: MINOR Proposed Repair Actions:

NO ACTION Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 27 TRAC Device Handler Error description: This error appears when the diagnostic performed on a TRAC without outstanding alarms fails. The TRAC is put disabled failed.

0102 (D)= for internal use only

0304 (D)= for internal use only

0507 (D)= for internal use only

0709 (D)= for internal use only

0910 (D)= for internal use only

1112 (D)= TRAC number

1314 (D)= 0xffff

1516 (D)= 0xffff

1718 (D)= 0xffff

1920 (D)= 0xffff

2122 (D)= 0xffff

2324 (D)= 0xffff

2526 (D)= 0xffff

2728 (D)= 0xffff

2930 (D)= 0xffff

Figure 2

Failure Event description example Each field that appears in Figure 2 is explained below: FAILURE EVENT REPORT: <Class> <Object> <Object Instance> <Class>: It determines unambiguously, togheter with the Error Id field the error.

Page 11: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 11

The following classes can report Failure Events: PCM_CIRCUIT 0

EQUIPMENT 1 LAPD_LINK 2 TRANSCODER 3 Presently not used TSLA 4 Presently not used ENVATRAUE 5 <Object>: PCMA 0 PCMS 1 TPWR 2 BSMS 3 TRAC 4 LAPD 5 TRAU 6 TSLA 7 ENVA 8 <Object Instance>:

Object number (e.g. BSMS copy 0 or 1). Note that this is an internal organization for Failure Events grouping and the operator does not need further information to accomplish the analysis. Probable Cause It is an abbreviated sentence that describes the probable cause of the error.

• Value for GSM12.11 specification: EQUIPMENT FAILURE 9 LINE INTERFACE FAILURE 16 LOSS OF SYNCHRONIZATION 18 DATABASE INCONSISTENCY 37 INPUT PARAMETER OUT OF RANGE 39 INVALID POINTER 41 MESSAGE NOT EXPECTED 42 MESSAGE OUT OF SEQUENCE 44 SYSTEM CALL UNSUCCESSFUL 45 TIMEOUT EXPIRED 46 VARIABLE OUT OF RANGE 47 WATCH DOG TIMER EXPIRED 48 FAN FAILURE 53 SYSTEM RESOURCES OVERLOAD 64 LAPD LINK PROTOCOL FAILURE 69 REMOTE ALARM INDICATION 71 TRANSMISSION ERROR 74 • Value for ISO X.721 specification: CONFIGURATION OR CUSTOMIZATION ERROR 7 CONGESTION 8 CORRUPT DATA 9 ENCLOSURE DOOR OPEN 14 LOSS OF FRAME 28 OUT OF MEMORY 32 SOFTWARE ERROR 46

Page 12: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

12 A30808-X3247-M440-1-7619

SW PROGRAM ABNORMALLY TERMINATED 47 (For further details see Annex A) Specific Problem This parameter identifies further refinements to the Probable Cause of the alarm according to the ITU-T Rec. X.733. In the Annex A, all the Specific Problems used by TRAU are provided with the Probable Cause of reference. Event Type This parameter defines the alarm categories. Five basic categories of alarm are specified according to CCITT X.733. There are:

COMMUNICATION FAILURE QUALITY OF SERVICE FAILURE PROCESSING FAILURE EQUIPMENT FAILURE ENVIRONMENTAL FAILURE Event Time This parameter identifies the time of detection or resolution of the fault and it is included in any Alarm Reporting notification. Severity According to CCITT X.733 the following severities can be reported - When an error occurs:

INDETERMINATE (not used in our system) CRITICAL MAJOR MINOR WARNING

- When an error ceases:

CLEARED In case of error ceased, please note that the message part that follows the Notification Identifier field is not printed by the Local Terminal. Trend Indication The following Trend Indication values can be reported:

LESS SEVERE NO CHANGE MORE SEVERE

Page 13: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 13

The LESS SEVERE trend indication is printed if the associated severity for the concerned object, is less severe of those associated to previously reported Failure Events relevant to the same object and still active (i.e. no related error ceased message was generated). The NO CHANGE trend indication is printed if the associated severity for the concerned object, is the same as the highest of those associated to previously reported Failure Events relevant to the same object and still active (i.e. no related error ceased message was generated). The MORE SEVERE trend indication is printed if the associated severity for the concerned object, is more severe of those associated to previously reported Failure Events relevant to the same object and still active (i.e. no related error ceased message was generated). When the trend indication is Not Applicable (i.e. when the alarm is the first concerning an object) it is not reported by LMT and OMC. Notification Identifier According to the ITU-T X.733 specification the Notification Identifiers is unique across all notifications of a particular managed object throughout the time that correlation is significant. Correlated Notification According to the ITU-T X.733 specification this parameter, when present, contains a set of Notification identifiers and their associated managed object instance names. This set is defined to be the set of all notifications to which this notification is considered to be correlated. Thus, this parameter, included in the FER, identifies the notifications to which this notification is considered to be correlated. The Correlated Notifications parameter is present in the Failure Event Report only when it is retransmitted during the Alarm Alignment. Proposed Repair Actions According to the ITU-T X.733 specification, the “Proposed Repair Actions” parameter suggests a solution to the operator to repair the problem reported in the notification. In Annex B, all the Proposed Repair Actions used in the TRAU FER are provided. Additional Text According to CCITT X.733 this part, when present, allows a free form text description to be reported. At present the Additional Text will contain the “associated string” if any in the environmental alarm. Originator It is an integer number that identifies the software module and the Task originating the Failure

Event. In Annex C all the TRAU Originator are provided. Additional Words 0102 ÷ 2930 are hex values that are helpful for a detailed description of the error. This part is particularly useful to the software designer for analyzing the error cause and taking proper actions to solve the problem.

Page 14: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

14 A30808-X3247-M440-1-7619

For each originator, under the Legend part of the Failure Event description, a concise description of the error and the meaning of the Additional Words are provided. VERY IMPORTANT NOTE: Anyway, if the problem persists, i.e. the system or operator actions are unsuccessful, or occur periodically, the failure events must be collected and reported to the manufacturing company for analysis.

Page 15: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 15

##1006-##1

3 GSM Probable Causes

3.1 Equipment Failure

3.1.1 1006 - PLL_FAILURE FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: EQUIPMENT FAILURE EVENT Probable Cause: Equipment Failure Specific Problems: PLL_FAILURE Severity: Major Proposed Repair Actions:

Test the addressed card(s) Test the addressed card(s) and perform the proper action according to the Test Result. Possibly, check also its (their) insertion in the frame.

Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 104 ALL1_PLL_ORIGINATOR Error description: The PLLALL1 interrupt is generated continuosly. This interrupt is originated by the arising of an hardware fault in the digital part of the PLL mounted on BSCI card. The PLL_ALL1 Interrupt Handler resets the BSCI card.

0102 (D)= not used

0304 (D)= not used

0506 (D)= not used

0708 (D)= not used

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##1006-##2

Page 16: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

16 A30808-X3247-M440-1-7619

##1007-##1

3.1.2 1007 - BSCI_HW_FAULT FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: EQUIPMENT FAILURE EVENT Probable Cause: Equipment Failure Specific Problems: BSCI_HW_FAULT Severity: Major Proposed Repair Actions:

See the automatic diagnostic test result Wait for the end of the Automatic Diagnostic and then perform the proper action according to the Test Result.

Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 111 BSMS Fault Detection Error description: An hardware fault occurred on BSCI Card. The BSMS is put in disabled failed state. The System starts the Automatic Diagnostic.

0102 (D)= Copy Number

0304 (D)= Identifier of the problem:

BSCI_RAM_PARITY_ERROR = 2

BSCI_TIMING_LOSS = 8

FORCE_ALLPLL2_FAILED = 55

FORCE_RAM_PARITY_FAILED = 57

FORCE_RAM_PROTECTION_FAILED = 58

BSCI_RAM_CORRUPTED = 85

0506 (D)= Internal Originator:

NMI_HANDLER_ORIGINATOR = 101

ALM_SPON_ORIGINATOR = 102

FAULT_DETECTION_BSMS = 111

TSK_TEST_BSMS = 120

0708 (D)= If Internal Originator (0506 ) = NMI_HANDLER_ORIGINATOR

Task Entry Point (FP_SEG)

If Internal Originator (0506 ) = ALM_SPON_ORIGINATOR

alarms

Internal Originator (0506 ) = FAULT_DETECTION_BSMS

page# checksum error

Internal Originator (0506 ) = TSK_TEST_BSMS

error info1

Page 17: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 17

0910 (D)= If Internal Originator (0506 ) = NMI_HANDLER_ORIGINATOR

Task Entry Point (FP_OFF)

If Internal Originator (0506 ) = ALM_SPON_ORIGINATOR

Not Used

Internal Originator (0506 ) = FAULT_DETECTION_BSMS

Not Used

Internal Originator (0506 ) = TSK_TEST_BSMS

error info2

1112 (D)= If Internal Originator (0506 ) = NMI_HANDLER_ORIGINATOR

Task Logic Name

If Internal Originator (0506 ) = ALM_SPON_ORIGINATOR

Not Used

Internal Originator (0506 ) = FAULT_DETECTION_BSMS

Not Used

Internal Originator (0506 ) = TSK_TEST_BSMS

0

1314 (D)= If Internal Originator (0506 ) = NMI_HANDLER_ORIGINATOR

InterruptStatusSaveArea.SavedRegs._CS

If Internal Originator (0506 ) = ALM_SPON_ORIGINATOR

Not Used

Internal Originator (0506 ) = FAULT_DETECTION_BSMS

Not Used

Internal Originator (0506 ) = TSK_TEST_BSMS

Not Used

1516 (D)= If Internal Originator (0506 ) = NMI_HANDLER_ORIGINATOR

InterruptStatusSaveArea.SavedRegs._IP

If Internal Originator (0506 ) = ALM_SPON_ORIGINATOR

Not Used

Internal Originator (0506 ) = FAULT_DETECTION_BSMS

Not Used

Internal Originator (0506 ) = TSK_TEST_BSMS

Not Used

1718 (D)= If Internal Originator (0506 ) = NMI_HANDLER_ORIGINATOR

InterruptStatusSaveArea.SavedRegs._ES

Page 18: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

18 A30808-X3247-M440-1-7619

If Internal Originator (0506 ) = ALM_SPON_ORIGINATOR

Not Used

Internal Originator (0506 ) = FAULT_DETECTION_BSMS

Not Used

Internal Originator (0506 ) = TSK_TEST_BSMS

Not Used

1920 (D)= If Internal Originator (0506 ) = NMI_HANDLER_ORIGINATOR

InterruptStatusSaveArea.SavedRegs._DS

If Internal Originator (0506 ) = ALM_SPON_ORIGINATOR

Not Used

Internal Originator (0506 ) = FAULT_DETECTION_BSMS

Not Used

Internal Originator (0506 ) = TSK_TEST_BSMS

Not Used

2122 (D)= If Internal Originator (0506 ) = NMI_HANDLER_ORIGINATOR

InterruptStatusSaveArea.SavedRegs._SI

If Internal Originator (0506 ) = ALM_SPON_ORIGINATOR

Not Used

Internal Originator (0506 ) = FAULT_DETECTION_BSMS

Not Used

Internal Originator (0506 ) = TSK_TEST_BSMS

Not Used

2324 (D)= If Internal Originator (0506 ) = NMI_HANDLER_ORIGINATOR

InterruptStatusSaveArea.SavedRegs._AX

If Internal Originator (0506 ) = ALM_SPON_ORIGINATOR

Not Used

Internal Originator (0506 ) = FAULT_DETECTION_BSMS

Not Used

Internal Originator (0506 ) = TSK_TEST_BSMS

Not Used

2526 (D)= If Internal Originator (0506 ) = NMI_HANDLER_ORIGINATOR

InterruptStatusSaveArea.SavedRegs._CX

If Internal Originator (0506 ) = ALM_SPON_ORIGINATOR

Not Used

Page 19: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 19

Internal Originator (0506 ) = FAULT_DETECTION_BSMS

Not Used

Internal Originator (0506 ) = TSK_TEST_BSMS

Not Used

2728 (D)= not used

2930 (D)= not used ##1007-##2

Page 20: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

20 A30808-X3247-M440-1-7619

##1009-##1

3.1.3 1009 - TRAC_TIMING_LOSS FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: EQUIPMENT FAILURE EVENT Probable Cause: Equipment Failure Specific Problems: TRAC_TIMING_LOSS Severity: Minor Proposed Repair Actions:

See the automatic diagnostic test result Wait for the end of the Automatic Diagnostic and then perform the proper action according to the Test Result.

Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 27 TRAC Device Handler Error description: The TRAC card synchronization sources are not valid, and therefore the TRAC card is not able to perform its operations. The TRAC is put in disabled state.The System starts the Automatic Diagnostic procedure.

0102 (D)= not used

0304 (D)= not used

0506 (D)= not used

0708 (D)= not used

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##1009-##2

Page 21: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 21

##1012-##1

3.1.4 1012 - PROTECTED_MEMORY_ILLEGAL_WRITE_ATTEMPT FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: EQUIPMENT FAILURE EVENT Probable Cause: Equipment Failure Specific Problems: PROTECTED_MEMORY_ILLEGAL_WRITE_ATTEMPT Severity: Major Proposed Repair Actions:

See the automatic diagnostic test result Wait for the end of the Automatic Diagnostic and then perform the proper action according to the Test Result.

Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 108 PROTECT_MEM_ORIGINATOR Error description: An illegal write attempt on a protected memory address has been trapped by the hardware. The protected memory regions include both the processor code area and the DBA data area. After the third illegal write attempt, the BSMS is set to disabled failed; the processor is put in halt mode and it does not restart by itself. The System starts the Automatic Diagnostic.

0102 (D)= Task Entry Point (FP_SEG)

0304 (D)= Task Entry Point (FP_OFF)

0506 (D)= Task Logic Name

0708 (D)= InterruptStatusSaveArea.SavedRegs._CS

0910 (D)= InterruptStatusSaveArea.SavedRegs._IP

1112 (D)= InterruptStatusSaveArea.SavedRegs._SS

1314 (D)= InterruptStatusSaveArea.SavedRegs._DS

1516 (D)= InterruptStatusSaveArea.SavedRegs._ES

1718 (D)= InterruptStatusSaveArea.SavedRegs._SP

1920 (D)= InterruptStatusSaveArea.SavedRegs._BP

2122 (D)= InterruptStatusSaveArea.SavedRegs._AX

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##1012-##2

Page 22: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

22 A30808-X3247-M440-1-7619

##1020-##1

3.1.5 1020 - PCMS_CIRCUIT_ALARM FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: EQUIPMENT FAILURE EVENT Probable Cause: Equipment Failure Specific Problems: PCMS_CIRCUIT_ALARM Severity: Major Proposed Repair Actions:

See the automatic diagnostic test result Wait for the end of the Automatic Diagnostic and then perform the proper action according to the Test Result.

Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 39 PCM Device Controller Task Error description: An Alarm on the circuit that manages the PCMS trunk on the BSCI card has arisen when either the trunk is NOT EQUIPPED or the BSCI belongs to the standby BSMS. It represents a BSCI HW fault. The PCM Device Controller Task informs BSMS Device Controller Task that reset the BSCI card. The BSCI remains in Firmware State. The BSMS is put disabled failed.The System starts the Automatic Diagnostic procedure.

0102 (D)= PCMS trunk alarmed:

PCMS TRUNK A ='A'

PCMS TRUNK B ='B'

0304 (D)= PCMS Alarm Type Identifier:

ALM_INTERNAL 0x01

ALM_LINE 0x02

ALM_ERATE 0x03

0506 (D)= PCMS Alarm Identifier:

BSCI V3 (DTIM-DTOM gate array(D))

mP address parity alarm = 01

mP data parity alarm = 02

DTIM clock slip alarm = 04

Timing Alarm = 08

RX Parity Alarm = 10

TX Parity Alarm = 40

BSCI V4 (FALC 54):

AIS ALARM = 01

MLF ALARM = 02

RAI ALARM = 04

LFA ALARM = 10

LOS ALARM = 20

Page 23: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 23

SYN ALARM = 40

SLIP ALARM = 80

0708 (D)= If Alarm type (0304) is ALM_LINE:

persisten alarm cause 0xaa

microinterruption alarm cause 0xcc

Otherwise:

0xffff

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##1020-##2

Page 24: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

24 A30808-X3247-M440-1-7619

##1021-##1

3.1.6 1021 - PCMA_CIRCUIT_ALARM FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: EQUIPMENT FAILURE EVENT Probable Cause: Equipment Failure Specific Problems: PCMA_CIRCUIT_ALARM Severity: Major Proposed Repair Actions:

See the automatic diagnostic test result Wait for the end of the Automatic Diagnostic and then perform the proper action according to the Test Result.

Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 39 PCM Device Controller Task Error description: An Alarm on the circuit that manage the PCMA trunk on the MSCI card has occurred when either the PCMA is NOT EQUIPPED or the MSCI belongs to the standby BSMS. It represents a MSCI HW fault. The PCM Device Controller Task informs BSMS Device Controller Task that reset the MSCI card. The MSCI remains in Firmware State. The BSMS is put disabled failed. The System starts the Automatic Diagnostic procedure.

0102 (D)= PCMA line alarmed:

PCMA Line 0 = 0

PCMA Line 1 = 01

PCMA Line 2 = 02

PCMA Line 3 = 03

0304 (D)= PCMA Alarm Type Identifier::

ALM_INTERNAL 0x01

ALM_LINE 0x02

ALM_ERATE 0x03

0506 (D)= PCMA Alarm Identifier:

mP address parity alarm = 01

mP data parity alarm = 02

DTIM clock slip alarm = 04

Timing Alarm = 08

RX Parity Alarm = 10

TX Parity Alarm = 40

0708 (D)= If Alarm type Identifier (0304) is ALM_LINE

0xaa

Otherwise:

0xffff

0910 (D)= not used

Page 25: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 25

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##1021-##2

Page 26: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

26 A30808-X3247-M440-1-7619

##1042-##1

3.1.7 1042 - BSMS_DIAGNOSTIC_FAILURE FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: EQUIPMENT FAILURE EVENT Probable Cause: Equipment Failure Specific Problems: BSMS_DIAGNOSTIC_FAILURE Severity: Major Proposed Repair Actions:

No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 26 BSMS Device Handler Error description: This error appears when the diagnostic performed on the Standby BSMS without outstanding alarms fails. The BSMS is put disabled failed.

0102 (D)= not used

0304 (D)= not used

0506 (D)= not used

0708 (D)= not used

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##1042-##2

Page 27: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 27

##1045-##1

3.1.8 1045 - TRAC_DIAGNOSTIC_FAILURE FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: EQUIPMENT FAILURE EVENT Probable Cause: Equipment Failure Specific Problems: TRAC_DIAGNOSTIC_FAILURE Severity: Minor Proposed Repair Actions:

No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 27 TRAC Device Handler Error description: This error appears when the diagnostic performed on a TRAC without outstanding alarms fails. The TRAC is put disabled failed.

0102 (D)= for internal use only

0304 (D)= for internal use only

0506 (D)= for internal use only

0708 (D)= for internal use only

0910 (D)= for internal use only

1112 (D)= TRAC number

1314 (D)= 0xffff

1516 (D)= 0xffff

1718 (D)= 0xffff

1920 (D)= 0xffff

2122 (D)= 0xffff

2324 (D)= 0xffff

2526 (D)= 0xffff

2728 (D)= 0xffff

2930 (D)= 0xffff ##1045-##2

Page 28: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

28 A30808-X3247-M440-1-7619

##1047-##1

3.1.9 1047 - TRAC_DIAGNOSTIC_ONLINE_FAILURE FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: EQUIPMENT FAILURE EVENT Probable Cause: Equipment Failure Specific Problems: TRAC_DIAGNOSTIC_ONLINE_FAILURE Severity: Minor Proposed Repair Actions:

See the automatic diagnostic test result Wait for the end of the Automatic Diagnostic and then perform the proper action according to the Test Result.

Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 27 TRAC Device Handler Error description: When this alarm occours, an automatic diagnostic starts. If diagnostic ends successfully, the TRAC card is put enabled. Vice versa, if diagnostic fails, the TRAC is put disabled failed.

0102 (D)= for internal use only

0304 (D)= for internal use only

0506 (D)= for internal use only

0708 (D)= for internal use only

0910 (D)= for internal use only

1112 (D)= TRAC number

1314 (D)= 0xffff

1516 (D)= On line diagnostic: card version: 0003 : TRACV3

0005 : TRACV5

1718 (D)= On line diagnostic:

If TRACV3 board:

Binary form: XXXX XXXX XXXX XXXX

where X=0 DSP(i) Asub Loop OK

X=1 DSP(i) Asub Loop Fault

If TRACV5 board:

Binary form: XXXX XXXX XXXX XXXX

where X=0 DSP Controller(i) Asub Loop OK

X=1 DSP Controller(i) Asub Loop Fault

1920 (D)= On Line diagnostic:

If TRACV3 board:

Binary form: 1111 1111 XXXX XXXX

where X=0 DSP(i) Asub Loop OK

X=1 DSP(i) Asub Loop Fault

Page 29: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 29

If TRACV5 board:

Binary form: 1111 1111 XXXX XXXX

where X=0 DSP Controller(i) Asub Loop OK

X=1 DSP Controller(i) Asub Loop Fault

2122 (D)= On Line diagnostic:

If TRACV3 board:

Binary form: XXXX XXXX XXXX XXXX

where X=0 DSP(i) A Loop OK

X=1 DSP(i) A Loop Fault

If TRACV5 board:

Binary form: XXXX XXXX XXXX XXXX

where X=0 DSP Algorithmic(i) A Loop OK

X=1 DSP Algorithmic(i) A Loop Fault

2324 (D)= On Line diagnostic:

If TRACV3 board:

Binary form: 1111 1111 XXXX XXXX

where X=0 DSP(i) A Loop OK

X=1 DSP(i) A Loop Fault

If TRACV5 board:

Binary form: 1111 1111 XXXX XXXX

where X=0 DSP Algorithmic(i) A Loop OK

X=1 DSP Algorithmic(i) A Loop Fault

2526 (D)= 0xffff

2728 (D)= 0xffff

2930 (D)= 0xffff ##1047-##2

Page 30: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

30 A30808-X3247-M440-1-7619

##1052-##1

3.1.10 1052 - TPWR_DIAGNOSTIC_FAILURE FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: EQUIPMENT FAILURE EVENT Probable Cause: Equipment Failure Specific Problems: TPWR_DIAGNOSTIC_FAILURE Severity: Major Proposed Repair Actions:

No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 16 Power Supply Device Controller Error description: This error appears when the diagnostic performed on a TPWR without outstanding alarms fails. The TPWR is put disabled failed.

0102 (D)= not used

0304 (D)= not used

0506 (D)= not used

0708 (D)= not used

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##1052-##2

Page 31: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 31

##1059-##1

3.1.11 1059 - MSCI_HW_FAULT FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: EQUIPMENT FAILURE EVENT Probable Cause: Equipment Failure Specific Problems: MSCI_HW_FAULT Severity: Major Proposed Repair Actions:

See the automatic diagnostic test result Wait for the end of the Automatic Diagnostic and then perform the proper action according to the Test Result.

Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 26 BSMS Device Handler Error description: The MSCI has a hardware problem which is detailed in the Additional Info. If the error concerns the providing service BSMS a copy switch is performed. The BSMS copy related to the faulty MSCI is put disabled failed. The System starts the Automatic Diagnostic.

0102 (D)= signal type

0304 (D)= signal subtype

0506 (D)= not used

0708 (D)= error code

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##1059-##2

Page 32: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

32 A30808-X3247-M440-1-7619

##1074-##1

3.1.12 1074 - TPWR_FAULT FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: EQUIPMENT FAILURE EVENT Probable Cause: Equipment Failure Specific Problems: TPWR_FAULT Severity: Major Proposed Repair Actions:

Test the addressed card(s) Test the addressed card(s) and perform the proper action according to the Test Result. Possibly, check also its (their) insertion in the frame.

Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 16 Power Supply Device Controller Error description: The TPWR has an hardware failure, or the TPWR internal fault detection circuitry is faulty. If the fault is such that the active BSMS does not receive the power supply, a BSMS copy switch is performed.

0102 (D)= not used

0304 (D)= not used

0506 (D)= not used

0708 (D)= not used

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##1074-##2

Page 33: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 33

##1077-##1

3.1.13 1077 - TRAC_HW_FAULT FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: EQUIPMENT FAILURE EVENT Probable Cause: Equipment Failure Specific Problems: TRAC_HW_FAULT Severity: Minor Proposed Repair Actions:

See the automatic diagnostic test result Wait for the end of the Automatic Diagnostic and then perform the proper action according to the Test Result.

Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 27 TRAC Device Handler Error description: The local TRAC fault detector test (WDT and TIMING) has failed. The TRAC state is set to disabled failed.The System starts the Automatic Diagnostic procedure.

0102 (D)= not used

0304 (D)= not used

0506 (D)= not used

0708 (D)= not used

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##1077-##2

Page 34: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

34 A30808-X3247-M440-1-7619

##1078-##1

3.1.14 1078 - MSCI_SYNC_8KHZ_FAILED FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: EQUIPMENT FAILURE EVENT Probable Cause: Equipment Failure Specific Problems: MSCI_SYNC_8KHZ_FAILED Severity: Major Proposed Repair Actions:

See the automatic diagnostic test result Wait for the end of the Automatic Diagnostic and then perform the proper action according to the Test Result.

Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 39 PCM Device Controller Task Error description: The 8KHz clock on MSCI card fails. This is the result of the MSCI Hardware fault related to this synchronism signal. The PCM device controller informs BSMS device controller that resets the BSCI and MSCI cards and puts the BSMS to disabled failed. The System starts the Automatic Diagnostic procedure.

0102 (D)= not used

0304 (D)= not used

0506 (D)= not used

0708 (D)= not used

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##1078-##2

Page 35: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 35

##1079-##1

3.1.15 1079 - MSCI_DIGA_FAULTED FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: EQUIPMENT FAILURE EVENT Probable Cause: Equipment Failure Specific Problems: MSCI_DIGA_FAULTED Severity: Major Proposed Repair Actions:

See the automatic diagnostic test result Wait for the end of the Automatic Diagnostic and then perform the proper action according to the Test Result.

Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 39 PCM Device Controller Task Error description: The gate array DIGA mounted on MSCI card has an internal hardware fault. The PCM device controller informs BSMS device controller that resets the BSCI and MSCI cards and puts the BSMS to disabled failed. The System starts the Automatic Diagnostic procedure.

0102 (D)= PCMA number (0-3)

0304 (D)= PCMA channel (1-31)

0506 (D)= loopback test inserted pattern

0708 (D)= fault cause

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##1079-##2

Page 36: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

36 A30808-X3247-M440-1-7619

##1081-##1

3.1.16 1081 - TRAC_FAIL_TO_LOAD FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: EQUIPMENT FAILURE EVENT Probable Cause: Equipment Failure Specific Problems: TRAC_FAIL_TO_LOAD Severity: Minor Proposed Repair Actions:

Test the addressed card(s) Test the addressed card(s) and perform the proper action according to the Test Result. Possibly, check also its (their) insertion in the frame.

Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 27 TRAC Device Handler Error description: It was not possible to load the TRAC card after 5 attempts. This is due to an hardware failure. The TRAC is put disabled failed.

0102 (D)= not used

0304 (D)= not used

0506 (D)= not used

0708 (D)= not used

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##1081-##2

Page 37: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 37

##1082-##1

3.1.17 1082 - FLASH_EPROM_NOT_VALID FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: EQUIPMENT FAILURE EVENT Probable Cause: Equipment Failure Specific Problems: FLASH_EPROM_NOT_VALID Severity: Major Proposed Repair Actions:

See the automatic diagnostic test result Wait for the end of the Automatic Diagnostic and then perform the proper action according to the Test Result.

Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 23 Data Base, 28 DOWNLOAD_TSK, 29 PERIPH_LOAD_TSK, 40 CROSSCOPY_TSK, 48 RI Task

Error description: An attempt to access to the Flash Eprom was failed, the Flash is damaged or in an inconsistent state. The System starts the Automatic Diagnostic procedure.

0102 (D)= kind of File system used:

FAFS = 1

SLFS = 2

0304 (D)= File system function called:

OPEN = 1

READ = 2

WRITE = 3

CLOSE = 4

ERASE = 5

SWCOMPL = 6

SWSTATUS = 7

FORMAT = 8

DIR = 9

DBREN = 10

0506 (D)= File System error number:

WRITE ERROR = 100 (byte write,read back failed)

VPP = 101 (VPP missing status reg. error)

BWS = 102 (byte write status reg. error)

VPP and BWS = 103ES = 104 (erase status reg. error)

VPP and ES = 105ES and BWS = 106

VPP, BWS and ES = 107

OPERATION TIMEOUT = 200

ERASE ERROR = 300

COMMAND SEQUENCE ERROR = 400

Page 38: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

38 A30808-X3247-M440-1-7619

0708 (D)= file name first letter (ASCII code)

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##1082-##2

Page 39: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 39

##1086-##1

3.1.18 1086 - TRAC_LINK_FAILURE FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: EQUIPMENT FAILURE EVENT Probable Cause: Equipment Failure Specific Problems: TRAC_LINK_FAILURE Severity: Minor Proposed Repair Actions:

See the automatic diagnostic test result Wait for the end of the Automatic Diagnostic and then perform the proper action according to the Test Result.

Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 27 TRAC Device Handler Error description: The link to the TRAC card could not be established, therefore it is not possible to send or receive messages from the given TRAC. This is probably due to a hardware failure on the TRAC card. The System starts the Automatic Diagnostic procedure.

0102 (D)= not used

0304 (D)= not used

0506 (D)= not used

0708 (D)= not used

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##1086-##2

Page 40: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

40 A30808-X3247-M440-1-7619

##1088-##1

3.1.19 1088 - TRAC_CARD_FAILURE FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: EQUIPMENT FAILURE EVENT Probable Cause: Equipment Failure Specific Problems: TRAC_CARD_FAILURE Severity: Minor Proposed Repair Actions:

Insert and test the addressed card Insert the addressed card in the frame. Then, test it. Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 27 TRAC Device Handler Error description: The TRAC card is extracted from the TRAU shelf.

0102 (D)= not used

0304 (D)= not used

0506 (D)= not used

0708 (D)= not used

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##1088-##2

Page 41: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 41

##1089-##1

3.1.20 1089 - DSP_FAIL_TO_LOAD FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: EQUIPMENT FAILURE EVENT Probable Cause: Equipment Failure Specific Problems: DSP_FAIL_TO_LOAD Severity: Minor Proposed Repair Actions:

Test the addressed card(s) Test the addressed card(s) and perform the proper action according to the Test Result. Possibly, check also its (their) insertion in the frame.

Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 27 TRAC Device Handler Error description: After 5 attempts to load the TRAC controller software and the DSP software, one or more DSPs has never answered to the TRAC controller. The traffic channels of the DSPs which failed the keepalive are probably failed. The error can be caused DSP code or by an hardware failure on the DSPs. The System set the TRAC State to faulty.

0102 (D)= not used

0304 (D)= not used

0506 (D)= not used

0708 (D)= not used

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##1089-##2

Page 42: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

42 A30808-X3247-M440-1-7619

##1100-##1

3.1.21 1100 - BSCI_CARD_FAILURE FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: EQUIPMENT FAILURE EVENT Probable Cause: Equipment Failure Specific Problems: BSCI_CARD_FAILURE Severity: Major Proposed Repair Actions:

Insert and test the addressed card Insert the addressed card in the frame. Then, test it. Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 122 BSCI Audit Error description: A BSCI card without outstanding alarms has been extracted.

0102 (D)= not used

0304 (D)= not used

0506 (D)= not used

0708 (D)= not used

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##1100-##2

Page 43: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 43

##1104-##1

3.1.22 1104 - BSCI_KEEP_ALIVE_ALARM FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: EQUIPMENT FAILURE EVENT Probable Cause: Equipment Failure Specific Problems: BSCI_KEEP_ALIVE_ALARM Severity: Major Proposed Repair Actions:

Test the addressed card(s) Test the addressed card(s) and perform the proper action according to the Test Result. Possibly, check also its (their) insertion in the frame.

Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 26 BSMS Device Handler, 38 Status Manager Notify Handler Error description: The BSCI card of the standby BSMS does not respond to the providing service BSMS keepalive requests. The BSMS copy is considered disabled.

0102 (D)= signal type

0304 (D)= signal subtype

0506 (D)= not used

0708 (D)= not used

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##1104-##2

Page 44: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

44 A30808-X3247-M440-1-7619

##1105-##1

3.1.23 1105 - MSCI_KEEP_ALIVE_ALARM FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: EQUIPMENT FAILURE EVENT Probable Cause: Equipment Failure Specific Problems: MSCI_KEEP_ALIVE_ALARM Severity: Major Proposed Repair Actions:

Test the addressed card(s) Test the addressed card(s) and perform the proper action according to the Test Result. Possibly, check also its (their) insertion in the frame.

Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 26 BSMS Device Handler Error description: The MSCI card of the indicated BSMS does not respond to the BSCI keepalive requests. If the error concerns the providing service BSMS a copy switch is performed. The related BSMS goes to disabled failed state.

0102 (D)= signal type

0304 (D)= signal subtype

0506 (D)= not used

0708 (D)= not used

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##1105-##2

Page 45: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 45

##1106-##1

3.1.24 1106 - INCONSISTENT_STATUS FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: EQUIPMENT FAILURE EVENT Probable Cause: Equipment Failure Specific Problems: INCONSISTENT_STATUS Severity: Major Proposed Repair Actions:

See the automatic diagnostic test result Wait for the end of the Automatic Diagnostic and then perform the proper action according to the Test Result.

Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 26 BSMS Device Handler Error description: The BSCI is not properly configured. If the error concerns the providing services BSMS a copy switch is performed. The related BSMS goes to disabled failed state . The System starts the Automatic Diagnostic procedure.

0102 (D)= Wrong polling configuration = 0

Wrong FPGA configuration = 1

0304 (D)= If 0102 = 1

Register G value

0506 (D)= not used

0708 (D)= not used

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##1106-##2

Page 46: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

46 A30808-X3247-M440-1-7619

##11-##1

3.2 Line Interface Failure

3.2.1 11 - LOSS_OF_SIGNAL FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: COMMUNICATION FAILURE EVENT Probable Cause: Line Interface Failure Specific Problems: LOSS_OF_SIGNAL Severity: Major Proposed Repair Actions:

Check cables, connections, line quality Check the related cables, connections and line quality.

Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 39 PCM Device Controller Task Error description: The line interface component (DTOM or FALC) does not receive the signal on a PCMS trunk without redundancy (the other trunk is NOT EQUIPPED or FAULTED) or on a PCMT line. PCM Device Controller informs Status Manager Task about trunk faulted. The PCM line is put in disable state.

0102 (S)= PCM line alarmed:

PCMT line 0 = 0

PCMT line 1 = 0x0001

PCMT line 2 = 0x0002

PCMT line 3 = 0x0003

PCMS trunk A = 0x000a

PCMS trunk B = 0x000b

0304 (D)= Alarm Type Identifier = 0x0002 (Line Alarm)

0506 (D)= Alarm value: it can be the OR of the following values:

AIS = 0x01

LCA = 0x02

RAI = 0x04

DTOM_EER = 0x08

LFA = 0x10

LOS = 0x20

0708 (D)= Persistent Alarm = 0x00aa

Alarm due to microinterruptions = 0x00cc

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

Page 47: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 47

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##11-##2

Page 48: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

48 A30808-X3247-M440-1-7619

##12-##1

3.2.2 12 - AIS_ALARM FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: COMMUNICATION FAILURE EVENT Probable Cause: Line Interface Failure Specific Problems: AIS_ALARM Severity: Major Proposed Repair Actions:

Check cables, connections, line quality Check the related cables, connections and line quality.

Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 39 PCM Device Controller Task Error description: An Ais alarm has occurred on a PCMS trunk without redundancy (the other trunk is NOT EQUIPPED or FAULTED) or on a PCMT line. This means that PCM stream is composed by bits that are all 1. PCM Device Controller informs Status Manager Task about trunk faulted. The PCM line is put in disable state.

0102 (S)= PCM line alarmed:

PCMT line 0 = 0

PCMT line 1 = 0x0001

PCMT line 2 = 0x0002

PCMT line 3 = 0x0003

PCMS trunk A = 0x000a

PCMS trunk B = 0x000b

0304 (D)= Alarm Type Identifier = 0x0002 (Line Alarm)

0506 (D)= Alarm value: it can be the OR of the following values:

AIS = 0x01

LCA = 0x02

RAI = 0x04

DTOM_EER = 0x08

LFA = 0x10

LOS = 0x20

0708 (D)= Persistent Alarm = 0x00aa

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

Page 49: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 49

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##12-##2

Page 50: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

50 A30808-X3247-M440-1-7619

##18-##1

3.2.3 18 - LOSS_OF_SIGNAL_ON_LINK_A FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: COMMUNICATION FAILURE EVENT Probable Cause: Line Interface Failure Specific Problems: LOSS_OF_SIGNAL_ON_LINK_A Severity: Minor Proposed Repair Actions:

Check cables, connections, line quality Check the related cables, connections and line quality.

Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 39 PCM Device Controller Task Error description: The line interface component (DTOM or FALC) does not receive the signal on a PCMS trunk with redundancy (the other trunk is ENABLED or DEGRADED). PCM Device Controller informs Status Manager Task about trunk faulted. If the trunk faulted was the active one, PCM Device Controller triggers the trunk switch: it enables the other PCMS trunk towards TRAC.

0102 (S)= PCM line alarmed:

PCMS trunk A = 0x000a

0304 (D)= Alarm Type Identifier = 0x0002 (Line Alarm)

0506 (D)= Alarm value: it can be the OR of the following values:

AIS = 0x01

LCA = 0x02

RAI = 0x04

DTOM_EER = 0x08

LFA = 0x10

LOS = 0x20

0708 (D)= Persistent Alarm = 0x00aa

Alarm due to microinterruptions = 0x00cc

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

Page 51: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 51

2930 (D)= not used ##18-##2

Page 52: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

52 A30808-X3247-M440-1-7619

##19-##1

3.2.4 19 - LOSS_OF_SIGNAL_ON_LINK_B FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: COMMUNICATION FAILURE EVENT Probable Cause: Line Interface Failure Specific Problems: LOSS_OF_SIGNAL_ON_LINK_B Severity: Minor Proposed Repair Actions:

Check cables, connections, line quality Check the related cables, connections and line quality.

Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 39 PCM Device Controller Task Error description: The line interface component (DTOM or FALC) does not receive the signal on a PCMS trunk with redundancy (the other trunk is ENABLED or DEGRADED). PCM Device Controller informs Status Manager Task about trunk faulted. If the trunk faulted was the active one, PCM Device Controller triggers the trunk switch: it enables the other PCMS trunk towards TRAC.

0102 (S)= PCM line alarmed:

PCMS trunk B = 0x000b

0304 (D)= Alarm Type Identifier = 0x0002 (Line Alarm)

0506 (D)= Alarm value: it can be the OR of the following values:

AIS = 0x01

LCA = 0x02

RAI = 0x04

DTOM_EER = 0x08

LFA = 0x10

LOS = 0x20

0708 (D)= Persistent Alarm = 0x00aa

Alarm due to microinterruptions = 0x00cc

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

Page 53: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 53

2930 (D)= not used ##19-##2

Page 54: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

54 A30808-X3247-M440-1-7619

##20-##1

3.2.5 20 - AIS_ALARM_ON_LINK_A FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: COMMUNICATION FAILURE EVENT Probable Cause: Line Interface Failure Specific Problems: AIS_ALARM_ON_LINK_A Severity: Minor Proposed Repair Actions:

Check cables, connections, line quality Check the related cables, connections and line quality.

Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 39 PCM Device Controller Task Error description: A Ais alarm has occurred on a PCMS trunk with redundancy (the other trunk is ENABLED or DEGRADED). This means that PCM stream is composed by bits that are all 1. PCM Device Controller informs Status Manager Task about trunk faulted. If the trunk faulted was the active one, PCM Device Controller triggers the trunk switch: it enables the other PCMS trunk towards TRAC.

0102 (S)= PCM line alarmed:

PCMS trunk A = 0x000a

0304 (D)= Alarm Type Identifier = 0x0002 (Line Alarm)

0506 (D)= Alarm value: it can be the OR of the following values:

AIS = 0x01

LCA = 0x02

RAI = 0x04

DTOM_EER = 0x08

LFA = 0x10

LOS = 0x20

0708 (D)= Persistent Alarm = 0x00aa

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

Page 55: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 55

2930 (D)= not used ##20-##2

Page 56: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

56 A30808-X3247-M440-1-7619

##21-##1

3.2.6 21 - AIS_ALARM_ON_LINK_B FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: COMMUNICATION FAILURE EVENT Probable Cause: Line Interface Failure Specific Problems: AIS_ALARM_ON_LINK_B Severity: Minor Proposed Repair Actions:

Check cables, connections, line quality Check the related cables, connections and line quality.

Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 39 PCM Device Controller Task Error description: An Ais alarm has occurred on a PCMS trunk with redundancy (the other trunk is ENABLED or DEGRADED). This means that PCM stream is composed by bits that are all 1. PCM Device Controller informs Status Manager Task about trunk faulted. If the trunk faulted was the active one, PCM Device Controller triggers the trunk switch: it enables the other PCMS trunk towards TRAC.

0102 (S)= PCM line alarmed:

PCMS trunk B = 0x000b

0304 (D)= Alarm Type Identifier = 0x0002 (Line Alarm)

0506 (D)= Alarm value: it can be the OR of the following values:

AIS = 0x01

LCA = 0x02

RAI = 0x04

DTOM_EER = 0x08

LFA = 0x10

LOS = 0x20

0708 (D)= Persistent Alarm = 0x00aa

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

Page 57: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 57

2930 (D)= not used ##21-##2

Page 58: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

58 A30808-X3247-M440-1-7619

##1097-##1

3.3 Loss of Synchronisation

3.3.1 1097 - BAD_PLL_INPUT_SYNCHRONISATION FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: COMMUNICATION FAILURE EVENT Probable Cause: Loss of Synchronisation Specific Problems: BAD_PLL_INPUT_SYNCHRONISATION Severity: Warning Proposed Repair Actions:

No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 107 ALL2_PLL Interrupt Handler Error description: This alarm arises when the PLL circuit is not able to lock itself to the input PCM synchronizing line because this line has a frequency deviation or excessive Jitter. The PCM synchronizing line has changed if other PCM (PCMA or PCMS) is available. Otherwise the PLL is forced into FREE_RUNNING state.

0102 (D)= not used

0304 (D)= not used

0506 (D)= not used

0708 (D)= not used

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##1097-##2

Page 59: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 59

##1019-##1

3.4 Database Inconsistency

3.4.1 1019 - INVALID_DATABASE_WARNING FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Database Inconsistency Specific Problems: INVALID_DATABASE_WARNING Severity: Warning Proposed Repair Actions:

No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 27 TRAC Device Handler, 48 RI Task Error description: A call to a Database Services function has failed.

0102 (D)= Source code line

0304 (D)= trac staus

0506 (D)= waiting

0708 (D)= flag

0910 (D)= diag state

1112 (D)= trac instance

1314 (D)= trac:0 subtable

1516 (D)= trac:1 subtable

1718 (D)= trac:2 subtable

1920 (D)= trac:3 subtable

2122 (D)= trac:4 subtable

2324 (D)= trac:5 subtable

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##1019-##2

Page 60: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

60 A30808-X3247-M440-1-7619

##1023-##1

3.4.2 1023 - TRAC_DBA_REFUSED FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: COMMUNICATION FAILURE EVENT Probable Cause: Database Inconsistency Specific Problems: TRAC_DBA_REFUSED Severity: Minor Proposed Repair Actions:

Test the addressed card(s) Test the addressed card(s) and perform the proper action according to the Test Result. Possibly, check also its (their) insertion in the frame.

Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 27 TRAC Device Handler Error description: The TRAC software has not accepted the transcoder matrix sent by the BSCI after a bringup or reloading. The cause can be a transcoder matrix with a wrong format. The TRAC card is put disabled failed.

0102 (D)= for internal use only

0304 (D)= for internal use only

0506 (D)= for internal use only

0708 (D)= for internal use only

0910 (D)= for internal use only

1112 (D)= transcoder matrix index [0..5, FF]

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##1023-##2

Page 61: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 61

##1091-##1

3.4.3 1091 - DATABASE_INCONSISTENCY_BRINGUP FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Database Inconsistency Specific Problems: DATABASE_INCONSISTENCY_BRINGUP Severity: Major Proposed Repair Actions:

No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 26 BSMS Device Handler Error description: A database inconsistency or corruption has been discovered. The system automatically restores a default database going temporarily out of service.

0102 (D)= signal type

0304 (D)= signal subtype

0506 (D)= bsms current state

0708 (D)= not used

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##1091-##2

Page 62: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

62 A30808-X3247-M440-1-7619

##1102-##1

3.4.4 1102 - PROBABLE_DATABASE_INCONSISTENCY FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Database Inconsistency Specific Problems: PROBABLE_DATABASE_INCONSISTENCY Severity: Warning Proposed Repair Actions:

No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 26 BSMS Device Handler Error description: A probable database inconsistency or corruption has been found on the standby BSMS. The involved BSMS copy is reset and reloaded. Its database is retrieved, through a crosscopy procedure, from the providing service BSMS.

0102 (D)= signal type

0304 (D)= signal subtype

0506 (D)= bsms curr state

0708 (D)= not used

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##1102-##2

Page 63: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 63

##1015-##1

3.5 Input Parameter out of Range

3.5.1 1015 - INPUT_PARAMETER_OUT_OF_RANGE_WARNING FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Input Parameter out of Range Specific Problems: INPUT_PARAMETER_OUT_OF_RANGE_WARNING Severity: Warning Proposed Repair Actions:

No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 18 IPC_COLLECTOR_TSK, 23 Data Base, 24 SM_COMM_TSK, 28 DOWNLOAD_TSK, 29 PERIPH_LOAD_TSK, 38 Status Manager Notify Handler, 40 CROSSCOPY_TSK, 42 BDGDMPEPR_TSK

Error description: A call with wrong parameters was issued. Case of originator 29

0102 (D)= code statement number

0304 (D)= error type or parameter value

0506 (D)= link (card) identifier: 00-05 TRAC 0-5

0708 (D)= processor identifier(meaningful for TRAC cards):

00 Trac controller

01 Dsp

0910 (D)= last transmitted packet

1112 (D)= FSM state value

1314 (D)= source system of received message

1516 (D)= signal type of received message

1718 (D)= signal subtype of received message

1920 (D)= transmitted bytes

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##1015-##2

Page 64: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

64 A30808-X3247-M440-1-7619

##1114-##1

3.6 Invalid Pointer

3.6.1 1114 - INVALID_POINTER_WARNING FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Invalid Pointer Specific Problems: INVALID_POINTER_WARNING Severity: Warning Proposed Repair Actions:

No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 123 RTE_ORIGINATOR Error description: An invalid pointer has been detected by the RTE+ operating system.

0102 (D)= 000e: a bad timing cell pointer has been detected

000f: a bad suspended link pointer address has been detected

0010: an undeclared function pointer has been detected

0015: a null pointer has been detected

0016: a scheduler error has been detected

0304 (D)= not used

0506 (D)= not used

0708 (D)= not used

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##1114-##2

Page 65: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 65

##1014-##1

3.7 Message not Expected

3.7.1 1014 - UNEXPECTED_MESSAGE FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Message not Expected Specific Problems: UNEXPECTED_MESSAGE Severity: Warning Proposed Repair Actions:

No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 16 Power Supply Device Controller, 19 IPC Dispatcher, 21 LMT_IO_DLM_TSK, 23 Data Base, 24 SM_COMM_TSK, 25 Alarm Reporting, 26 BSMS Device Handler, 27 TRAC Device Handler, 28 DOWNLOAD_TSK, 38 Status Manager Notify Handler, 39 PCM Device Controller Task, 40 CROSSCOPY_TSK, 42 BDGDMPEPR_TSK, 47 DC ENVA TSK, 48 RI Task, 134 TDGDM_PI_PROCESS, 135 TDGDMPI_STBY, 145 FDGDM_OUTPUT

Error description: This error is displayed when an Area receives a message not admitted. The possible additional information are not relevant.

0102 (D)= not used

0304 (D)= not used

0506 (D)= not used

0708 (D)= not used

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##1014-##2

Page 66: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

66 A30808-X3247-M440-1-7619

##1044-##1

3.7.2 1044 - INVALID_MESSAGE_DATA FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Message not Expected Specific Problems: INVALID_MESSAGE_DATA Severity: Warning Proposed Repair Actions:

No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 18 IPC_COLLECTOR_TSK, 19 IPC Dispatcher, 20 IPC Link Maneger, 23 Data Base, 25 Alarm Reporting, 28 DOWNLOAD_TSK, 29 PERIPH_LOAD_TSK, 32 BSC_LINKMNGR_TSK, 38 Status Manager Notify Handler

Error description: In case of Originator 29,this error is displayed when an Area receives a message with wrong data.

0102 (D)= code statement number

0304 (D)= error type or parameter value

0506 (D)= not meaningful

0708 (D)= not meaningful

0910 (D)= not meaningful

1112 (D)= not meaningful

1314 (D)= source system of received message

1516 (D)= signal type of received message

1718 (D)= signal subtype of received message

1920 (D)= not meaningful

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##1044-##2

Page 67: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 67

##1048-##1

3.7.3 1048 - INVALID_RTE_HEADER_FIELD_VALUE FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Message not Expected Specific Problems: INVALID_RTE_HEADER_FIELD_VALUE Severity: Warning Proposed Repair Actions:

No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 28 DOWNLOAD_TSK, 32 BSC_LINKMNGR_TSK, 41 Sync Device Handler Error description: A message with an incorrect/unexpected RTE header field value has been received. In case of Originator = 28, the Download is aborted. Case of Originator = 32

0102 (D)= Source mailbox of received message

0304 (D)= Signal type of received message

0506 (D)= Signal subtype of received message

0708 (D)= Data lenght of received message

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##1048-##2

Page 68: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

68 A30808-X3247-M440-1-7619

##1060-##1

3.7.4 1060 - MSCI_SW_ERROR FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Message not Expected Specific Problems: MSCI_SW_ERROR Severity: Warning Proposed Repair Actions:

No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 26 BSMS Device Handler Error description: MSCI has received an invalid message.

0102 (D)= signal type

0304 (D)= signal subtype

0506 (D)= 0xff

0708 (D)= type of error

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##1060-##2

Page 69: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 69

##1080-##1

3.7.5 1080 - TRAC_UNEXPECTED_MESSAGE FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Message not Expected Specific Problems: TRAC_UNEXPECTED_MESSAGE Severity: Warning Proposed Repair Actions:

No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 27 TRAC Device Handler Error description: An unexpected message has been received from the TRAC card.

0102 (D)= Trac card number

0304 (D)= Source system

0506 (D)= Destination system

0708 (D)= signal type

0910 (D)= signal subtype

1112 (D)= datalen

1314 (D)= TRAC D.H. internal state

1516 (D)= message data

1718 (D)= message data

1920 (D)= message data

2122 (D)= message data

2324 (D)= message data

2526 (D)= message data

2728 (D)= message data

2930 (D)= message data ##1080-##2

Page 70: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

70 A30808-X3247-M440-1-7619

##1033-##1

3.8 Message Out of Sequence

3.8.1 1033 - MESSAGE_OUT_OF_SEQUENCE_WARNING FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Message Out of Sequence Specific Problems: MESSAGE_OUT_OF_SEQUENCE_WARNING Severity: Warning Proposed Repair Actions:

No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 32 BSC_LINKMNGR_TSK, 35 Alignment Service Task, 38 Status Manager Notify Handler Error description: The message received is not the expected one

0102 (D)= Originator 32: for internal use only

Originator 35 : for internal use only ('C' statement number)

Originator 38: object class

- possible values: 0x84 = sAsubEquipment

0x86 = sAsub_trauSyncronization

the other possible values are for internal use only

0304 (D)= Originator 32: for internal use only

Originator 35: for internal use only (internal FSM state)

Originator 38: meaningfull only if 0102 = 0x84

- possible value: 0x01 = TRAC.

0506 (D)= Originator 32: for internal use only

Originator 35: for internal use only (source system of received message)

Originator 38: meaningfull only if 0102 = 0x84

- possible values : TRAC instance.

0708 (D)= Originator 32: for internal use only

Originator 35: for internal use only (source mailbox of received message)

Originator 38: for internal use only (internal FSM state).

0910 (D)= Originator 32: for internal use only

Originator 35: for internal use only (signal type of received message)

Originator 38: for internal use only (internal FSM event).

1112 (D)= Originator 32 for internal use only

Originator 35: for internal use only (signal subtype of received message)

1314 (D)= Originator 35: for internal use only (data length of received message)

1516 (D)= not used

1718 (D)= not used

Page 71: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 71

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used

Originator: 28 DOWNLOAD_TSK

Error description: The packet received is not the expected one. The Download is aborted.

0102 (D)= Expected LDS packet number

0304 (D)= Received LDS packet number

0506 (D)= not used

0708 (D)= not used

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##1033-##2

Page 72: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

72 A30808-X3247-M440-1-7619

##1024-##1

3.9 System Call Unsuccessful

3.9.1 1024 - SYSTEM_CALL_UNSUCCESSFUL_WARNING FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: System Call Unsuccessful Specific Problems: SYSTEM_CALL_UNSUCCESSFUL_WARNING Severity: Warning Proposed Repair Actions:

No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 35 Alignment Service Task Error description:

0102 (D)= code statement number

0304 (D)= FSM state value

0506 (D)= not used

0708 (D)= not used

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used

Originator: 16 Power Supply Device Controller, 18 IPC_COLLECTOR_TSK, 19 IPC Dispatcher, 20

IPC Link Maneger, 23 Data Base, 24 SM_COMM_TSK, 25 Alarm Reporting, 26 BSMS Device Handler, 27 TRAC Device Handler, 28 DOWNLOAD_TSK, 29 PERIPH_LOAD_TSK, 32 BSC_LINKMNGR_TSK, 34 RAM CRC, 35 Alignment Service Task, 38 Status Manager Notify Handler, 39 PCM Device Controller Task, 40 CROSSCOPY_TSK, 41 Sync Device Handler, 42 BDGDMPEPR_TSK, 48 RI Task, 100 Error Collector, 102 Spontaneous Alarm, 111 BSMS Fault Detection, 116 WDT Fault Detection, 120 Test BSMS, 130 FDGDM_DIAG_ACTIVATION0, 131 FDGDM_DIAG_ACTIVATION1, 132 SEND_TEST_IN_PROGRESS, 133 SEND_PHASE_RESULT, 138 FDGDM_SYNC_DEVICE0, 139 FDGDM_SYNC_DEVICE1, 140 STOP_TEST_RUNNING, 141 SEND_DSC_TO_SM, 142 UPDATE_BSCI_STBY, 143 SEND_OUTPUT_RESULT, 144 SEND_DUMMY_RESULT, 146 FDGHD_BSMS, 147

Page 73: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 73

FDGHD_TRAC, 148 FDGHD_TPWR, 149 MSCI_DIAG_CONTROLLER, 150 TDGHD_BSMS_STBY

Error description: A system call was issued without success. Following Additional Words are not always used. Case of Originator = 29

0102 (D)= code statement number

0304 (D)= error type or parameter value

0506 (D)= link (card) identifier: 00 - 05 TRAC 0-5

06 MSCI

0708 (D)= processor identifier (meaningful for TRAC cards)

00 Trac controller

01 Dsp

0910 (D)= last transmitted packet

1112 (D)= FSM state value

1314 (D)= source system of received message

1516 (D)= signal type of received message

1718 (D)= signal subtype of received message

1920 (D)= transmitted bytes

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used

Originator: 46 EVENT_LOG_TSK

Error description: This error occours when Event Log task tries to flush the log buffer.The log is however appended and the log is flushed the next time the task runs.

0102 (D)= error code line

0304 (D)= signal subtype

0506 (D)= not used

0708 (D)= not used

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##1024-##2

Page 74: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

74 A30808-X3247-M440-1-7619

##1028-##1

3.9.2 1028 - FUNCTION_CALL_UNSUCCESSFUL FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: System Call Unsuccessful Specific Problems: FUNCTION_CALL_UNSUCCESSFUL Severity: Warning Proposed Repair Actions:

No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 19 IPC Dispatcher Error description: Interprocessor Communication internal error (dl_receive() failure)

0102 (D)= not used

0304 (D)= not used

0506 (D)= not used

0708 (D)= not used

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used

Originator: 24 SM_COMM_TSK

Error description: Unable to get an attribute value from the system, that refueses the Get Attribute command.

0102 (D)= attribute identifier:

E_AI_DIRECTORY_LIST = 0x85

E_AI_RUNNING_FILES = 0x8D

E_AI_TRAU_SW_LOAD_HEADER = 0x94

E_AI_LMT_SESSION = 0xC6

E_AI_LMT_LOGON_TIME = 0xC7

Page 75: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 75

E_AI_LMT_USR_ACCESS_LEVEL = 0xC8

E_AI_LMT_USR_NAME = 0xC9

0304 (D)= not used

0506 (D)= not used

0708 (D)= not used

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used

Originator: 39 PCM Device Controller Task

Error description: Unable to get information from database (fomdb_read_table() failure)

0102 (D)= signal_type

INTRAPROCESSOR = 0xFFFF

0304 (D)= signal_subtype

COMDB_DH_SET_PCMS = 0x0715

0506 (D)= not used

0708 (D)= not used

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used

Originator: 23 Data Base, 48 RI Task

Error description:

Page 76: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

76 A30808-X3247-M440-1-7619

Unable to send an internal message. In the following cases: 0102 = INTRAPROCESSOR 0xffff 0304 = COMDB_LOAD_MSCI_DB 0x712 COMDB_DH_SET_PCMS 0x715 the system reset is performed.

0102 (D)= signal_type

0304 (D)= signal_subtype

0506 (D)= not used

0708 (D)= not used

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##1028-##2

Page 77: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 77

##1066-##1

3.9.3 1066 - MESSAGE_NOT_SENT FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: System Call Unsuccessful Specific Problems: MESSAGE_NOT_SENT Severity: Warning Proposed Repair Actions:

No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 21 LMT_IO_DLM_TSK, 32 BSC_LINKMNGR_TSK Error description: One or more messages hasn't been sent. In general a previous system call was failed.

0102 (D)= RTE Header field, Operating System Pool Type Memory .

0304 (D)= RTE Header field, Source System.

0506 (D)= RTE Header field, Destination System.

0708 (D)= RTE Header field, Source Mailbox.

0910 (D)= RTE Header field, Destination Mailbox.

1112 (D)= RTE Header field, Signal Type.

1314 (D)= RTE Header field, Signal SubType.

1516 (D)= RTE Header field, Data Length.

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used

Originator: 24 SM_COMM_TSK, 38 Status Manager Notify Handler

Error description: One or more messages hasn't been sent. In general a previous system call was failed.

0102 (D)= Sygnal Subtype of the MSG Lost

0304 (D)= Object Type.

0506 (D)= Object Instance.

0708 (D)= not used

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

Page 78: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

78 A30808-X3247-M440-1-7619

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##1066-##2

Page 79: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 79

##1067-##1

3.9.4 1067 - INVALID_DB_CALL FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: System Call Unsuccessful Specific Problems: INVALID_DB_CALL Severity: Warning Proposed Repair Actions:

No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 23 Data Base Error description: A wrong access to TRAU Database has been performed. The access to Database is refused.

0102 (D)= not used

0304 (D)= not used

0506 (D)= not used

0708 (D)= not used

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##1067-##2

Page 80: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

80 A30808-X3247-M440-1-7619

##1096-##1

3.9.5 1096 - SYSTEM_CALL_UNSUCCESSFUL_MINOR FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: System Call Unsuccessful Specific Problems: SYSTEM_CALL_UNSUCCESSFUL_MINOR Severity: Major Proposed Repair Actions:

Test the card if it is a standby one If the addressed card is the StandBy one, test it. Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 26 BSMS Device Handler Error description: Unsuccessful function call. This error implies a serious system malfunction. The BSMS is put in disabled failed state by the system.

0102 (D)= error code

0304 (D)= signal type

0506 (D)= signal subtype

0708 (D)= not used

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##1096-##2

Page 81: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 81

##1037-##1

3.10 Timeout Expired

3.10.1 1037 - TIMEOUT_EXPIRED_WARNING FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Timeout Expired Specific Problems: TIMEOUT_EXPIRED_WARNING Severity: Warning Proposed Repair Actions:

No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 151 BSCI FW Error description: BSCI FW notifies that BSCI flash memory eeprom is empty or the stand-by card is extracted. SW version is not avaiable because FW doesn't have the acknowledge.

0102 (D)= not used

0304 (D)= not used

0506 (D)= not used

0708 (D)= not used

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used

Originator: 23 Data Base, 26 BSMS Device Handler, 28 DOWNLOAD_TSK, 29 PERIPH_LOAD_TSK,

38 Status Manager Notify Handler, 40 CROSSCOPY_TSK, 46 EVENT_LOG_TSK, 151 BSCI FW

Error description: Case of Originator = 23 Timeout expiring while waiting a message.

0102 (D)= not used

Page 82: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

82 A30808-X3247-M440-1-7619

0304 (D)= not used

0506 (D)= not used

0708 (D)= not used

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used

Originator: 26 BSMS Device Handler

Error description: Timeout expiring while waiting a message.

0102 (D)= signal type

0304 (D)= signal subtype

0506 (D)= not used

0708 (D)= not used

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used

Originator: 38 Status Manager Notify Handler

Error description: Timeout expiring while waiting a message.

0102 (D)= message Id.

0304 (D)= FSM state

0506 (D)= not used

0708 (D)= not used

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

Page 83: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 83

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used

Originator: 46 EVENT_LOG_TSK

Error description: Timeout expiring while waiting a message.

0102 (D)= not used

0304 (D)= not used

0506 (D)= not used

0708 (D)= not used

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used

Originator: 40 CROSSCOPY_TSK

Error description: Timeout expiring while waiting a message. Crosscopy aborted by the system.

0102 (D)= not used

0304 (D)= not used

0506 (D)= not used

0708 (D)= not used

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

Page 84: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

84 A30808-X3247-M440-1-7619

2930 (D)= not used

Originator: 28 DOWNLOAD_TSK

Error description: Timeout expiring while waiting a message. Downloading aborted by the system.

0102 (D)= not used

0304 (D)= not used

0506 (D)= not used

0708 (D)= not used

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used

Originator: 29 PERIPH_LOAD_TSK

Error description: Timeout expiring while waiting a message. Peripheral loading aborted by the system.

0102 (D)= code statement number

0304 (D)= error type or parameter value

0506 (D)= link (card) identifier: 00-05 TRAC 0-5

06 MSCI

0708 (D)= processor identifier(meaningful for TRAC cards):

00 Trac controller

01 Dsp

0910 (D)= last transmitted packet

1112 (D)= FSM state value

1314 (D)= source system of received message

1516 (D)= signal type of received message

1718 (D)= signal subtype of received message

1920 (D)= transmitted bytes

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##1037-##2

Page 85: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 85

##1075-##1

3.10.2 1075 - TRAC_KEEP_ALIVE_ALARM FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: COMMUNICATION FAILURE EVENT Probable Cause: Timeout Expired Specific Problems: TRAC_KEEP_ALIVE_ALARM Severity: Minor Proposed Repair Actions:

Test the addressed card(s) Test the addressed card(s) and perform the proper action according to the Test Result. Possibly, check also its (their) insertion in the frame.

Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 27 TRAC Device Handler Error description: The TRAC card has not answered within the answer time to a previsouly sent message. The TRAC is put in disabled failed state.

0102 (D)= not used

0304 (D)= not used

0506 (D)= not used

0708 (D)= not used

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##1075-##2

Page 86: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

86 A30808-X3247-M440-1-7619

##1087-##1

3.10.3 1087 - DSP_TSYNC_EXPIRED FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Timeout Expired Specific Problems: DSP_TSYNC_EXPIRED Severity: Warning Proposed Repair Actions:

No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 27 TRAC Device Handler Error description: A TSYNC timer expired for one ASUB time slot. This means that, for a time interval equal or greater than the TSYNC (or TTRAU) value, on the specified ASUB subtimeslot no idle pattern neither TRAU frames have been detected. This happens when the ASUB line is disconnected or in case of network or BTS failure. The notification comes from the DSPs on the TRAC cards. When the error arises on the same Asub time slot with a frequency of about 4 minutes two cases are possible: - the Asub line is disconnected or unstable; - a fault of one or more receivers of the TRAC board is detected.

0102 (D)= for internal use only

0304 (D)= for internal use only

0506 (D)= for internal use only

0708 (D)= for internal use only

0910 (D)= for internal use only

1112 (D)= The subtimeslot number (in the range 0..127) on the ASUB on which the TSYNC expired.

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##1087-##2

Page 87: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 87

##1090-##1

3.10.4 1090 - DSP_KEEP_ALIVE_ALARM FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: COMMUNICATION FAILURE EVENT Probable Cause: Timeout Expired Specific Problems: DSP_KEEP_ALIVE_ALARM Severity: Minor Proposed Repair Actions:

Replace the addressed card Replace the addressed card. Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 27 TRAC Device Handler Error description: As a result of the continous keepalive polling of the DSPs status on the TRAC card, one or more DSPs has ceased answering to the TRAC controller. The traffic channels of the DSPs which failed the keepalive are probably failed. The error can be caused by a software error on the DSP code or by an hardware failure on the DSPs; the exact cause can be found only after reloading the TRAC. When this error occurs, two cases must be distinguish: 1) If BSMS Standby copy has Operational State equal to ENABLE and Administrative State equal to UNLOCKED the behavior is as follow: An automatic diagnostic starts, if it ends successful the TRAC is put in Operational State ENABLE, vice versa, if the diagnostic fails, the TRAC is put in Operational State DISABLE. 2) If BSMS Standby copy has Operational State equal to DISABLE and/or Administrative State equal to LOCKED, the behavior is as follow: An automatic diagnostic starts, and the test phase "BSCILoopTest" is skipped; for this reason it isn't possible to detect the alarm. If further DSP_KEEPALIVE_ALARM occurs within 15 minutes, another automatic diagnostic starts; If the last diagnostic ends successful the TRAC is put in Operational State ENABLE, vice versa, if the second diagnostic ends unsuccessful, the alarm 'DSP_FAIL_TO_LOAD' is sent and the TRAC is put in Operational State DISABLE. Note: the following additional words are meaningful only if the trac is Enabled.

0102 (D)= If TRACV1 board:

Binary form: 1111 1111 XXXX XXXX

where X=0 DSP(i) general failure

X=1 DSP(i) OK

If TRACV3 board:Binary form: XXXX XXXX XXXX XXXX

where X=0 DSP(i) general failure

Page 88: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

88 A30808-X3247-M440-1-7619

X=1 DSP(i) OK

If TRACV5 board: Binary form: XXXY XXXY XXXY XXXY

where Y=0 DSP Controller(j) general failure

Y=1 DSP Controller(j) OK

X=0 DSP Algorithmic(i) general failure

X=1 DSP Algorithmic(i) OK

and (0<=j<=3, 0<=i<=11)

If TRACV7 board: Binary form:1111 1111 1111 11XX

where X=0 DSP(i) general failure

X=1 DSP(i) OK

0<=i<=1

0304 (D)= If TRACV1 board:

Binary form: 1111 1111 1111 1111

If TRACV3 board:

Binary form: 1111 1111 XXXX XXXX

where X=0 DSP(i) general failure

X=1 DSP(i) OK

If TRACV5 board:

Binary form: 1111 1111 1111 1111

If TRACV7 board:

Binary form: 1111 1111 1111 1111

0506 (D)= card version: 0001 : TRACV1

0003 : TRACV3

0005 : TRACV5

0007: TRACV7

0708 (D)= If TRACV1 board:

Binary form: 1111 1111 XXXX XXXX

where X=0 DSP(i) Keep_Alive response failure

X=1 DSP(i) Keep_Alive response OK

If TRACV3 board:

Binary form: XXXX XXXX XXXX XXXX

where X=0 DSP(i) Keep_Alive response failure

X=1 DSP(i) Keep_Alive response OK

If TRACV5 board:

Binary form: XXXY XXXY XXXY XXXY

where Y=0 DSP Controller(j) Keep_Alive response failure

Y=1 DSP Controller(j) Keep_Alive response OK

X=0 DSP Algorithmic(i) Communication failure

X=1 DSP Algorithmic(i) Communication OK

and (0<=j<=3, 0<=i<=11)

If TRACV7 board:

Page 89: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 89

Binary form: 1111 1111 1111 11XX

where X=0 DSP(i) response failure (no response received from DSP)

X=1 DSP(i) DSP OK

and 0<=i<=1

0910 (D)= If TRACV1 board:

Binary form: 1111 1111 1111 1111

If TRACV3 board:Binary form: 1111 1111 XXXX XXXX

where X=0 DSP(i) Keep_Alive response failure

X=1 DSP(i) Keep_Alive response OK

If TRACV5 board:

Binary form: 1111 1111 1111 1111

If TRACV7 board:

Binary form: 1111 1111 1111 1111

1112 (D)= If TRACV1 board:

Binary form: 1111 1111 XXXX XXXX

where X=1 DSP(i) Check_sum failure

X=0 DSP(i) Check_sum OK

If TRACV3 board:

Binary form: XXXX XXXX XXXX XXXX

where X=1 DSP(i) Check_sum failure

X=0 DSP(i) Check_sum OK

If TRACV5 board:Binary form: XXXY XXXY XXXY XXXY

where Y=1 DSP Controller(j) Check_sum failure

Y=0 DSP Controller(j) Check_sum OK

X=1 DSP Algorithmic(i) Check_sum failure

X=0 DSP Algorithmic(i) Check_sum OK

and (0<=j<=3, 0<=i<=11)

If TRACV7 board:Binary form: 0000 0000 0000 XYXY

where Y=0 DSP(i) Data Memory Checksum OK

Y=1 DSP(i) Data Memory Checksum Error

X=0 DSP(i) Code Memory Checksum OK

X=1 DSP(i) Code Memory Checksum Error

1314 (D)= If TRACV1 board:

Binary form: 1111 1111 1111 1111

If TRACV3 board:

Binary form: 1111 1111 XXXX XXXX

where X=1 DSP(i) Check_sum failure

X=0 DSP(i) Check_sum OK

If TRACV5 board:

Binary form: 1111 1111 1111 1111

Page 90: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

90 A30808-X3247-M440-1-7619

If TRACV7 board:

Binary form: 0000 0000 0000 0000

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##1090-##2

Page 91: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 91

##1029-##1

3.11 Variable Out of Range

3.11.1 1029 - VARIABLE_OUT_OF_RANGE FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Variable Out of Range Specific Problems: VARIABLE_OUT_OF_RANGE Severity: Warning Proposed Repair Actions:

No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 27 TRAC Device Handler, 48 RI Task, 136 FDGDM_IRAS Error description: Case 27: A message containing an invalid field value was received by the TRAC Device Controller, or an inconsistent internal TRAC Device Controller state has been detected. Case 48, 136: A message containing an invalid field value was received.

0102 (D)= not used

0304 (D)= not used

0506 (D)= not used

0708 (D)= not used

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##1029-##2

Page 92: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

92 A30808-X3247-M440-1-7619

##1003-##1

3.12 Watch Dog Timer Expired

3.12.1 1003 - TRAC_WDT_TIMEOUT FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Watch Dog Timer Expired Specific Problems: TRAC_WDT_TIMEOUT Severity: Minor Proposed Repair Actions:

Test the addressed card(s) Test the addressed card(s) and perform the proper action according to the Test Result. Possibly, check also its (their) insertion in the frame.

Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 27 TRAC Device Handler Error description: The TRAC card watchdog timer has expired, probably due to a software error on the TRAC controller software. The TRAC Device Controller attempts to reset the TRAC card which caused the error, then tries to reload it with software. The TRAC card goes to disabled faulty state until the link toward it is established again.

0102 (D)= not used

0304 (D)= not used

0506 (D)= not used

0708 (D)= not used

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##1003-##2

Page 93: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 93

##1004-##1

3.12.2 1004 - BSCI_WDT_TIMEOUT FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Watch Dog Timer Expired Specific Problems: BSCI_WDT_TIMEOUT Severity: Major Proposed Repair Actions:

No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 101 NMI Interrupt Handler Error description: A Watch Dog Timer has expired on BSCI card. When the observed value is 3 the NMI Interrupt Handler resets the BSCI card.

0102 (D)= Object Instance

BSMS copy: 0 = 00

BSMS copy: 1 = 01

0304 (D)= Error Id (BSCI_WDT_TIMEOUT)

0506 (D)= Originator Id (NMI Interrupt Handler)

0708 (D)= wdt occurrence counter

0910 (D)= Task Entry Point Segment value

1112 (D)= Task Entry Point Offset value

1314 (D)= Task Logic Name value

1516 (D)= Code Segment value

1718 (D)= Instruction Ponter value

1920 (D)= Stack Segment value

2122 (D)= Data Segment value

2324 (D)= Extra Segment value

2526 (D)= Stack Pointer value

2728 (D)= Base Pointer value

2930 (D)= AX ##1004-##2

Page 94: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

94 A30808-X3247-M440-1-7619

##1005-##1

3.12.3 1005 - BSCI_WDT_WARNING FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Watch Dog Timer Expired Specific Problems: BSCI_WDT_WARNING Severity: Warning Proposed Repair Actions:

No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 101 NMI Interrupt Handler Error description: A Watch Dog Timer has expired on BSCI card.

0102 (D)= Object Instance

BSMS copy: 0 = 00

BSMS copy: 1 = 01

0304 (D)= Error Id (BSCI_WDT_WARNING)

0506 (D)= Originator Id (NMI Interrupt Handler)

0708 (D)= wdt occurrence counter

0910 (D)= Task Entry Point Segment value

1112 (D)= Task Entry Point Offset value

1314 (D)= Task Logic Name value

1516 (D)= Code Segment value

1718 (D)= Instruction Pointer value

1920 (D)= Stack Segment value

2122 (D)= Data Segment value

2324 (D)= Extra Segment value

2526 (D)= Stack Pointer value

2728 (D)= Base Pointer valu

2930 (D)= AX ##1005-##2

Page 95: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 95

##5002-##1

3.13 FAN Failure

3.13.1 5002 - FAN_ALARM FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: ENVIRONMENTAL FAILURE EVENT Probable Cause: FAN Failure Specific Problems: FAN_ALARM Severity: Critical Proposed Repair Actions:

See the foreseen operating company repair action Environmental alarm. The repair action is defined by the operating company.

Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 47 DC ENVA TSK Error description: The alarm persistency sensed by the Scan Work Function which polls the ENVA sense point on the BSCI card has reached the threshold fixed by the operator.

0102 (D)= for internal use only

0304 (D)= for internal use only

0506 (D)= ENVA instance = 0

0708 (D)= Threshold

0910 (D)= Counter

1112 (D)= Name of ENVA

1314 (D)= Scan Work Function FLAG:

Disabled = 0

Enabled = 1

1516 (D)= Interface logic

Negative logic = 0

Positive logic = 1

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##5002-##2

Page 96: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

96 A30808-X3247-M440-1-7619

##1115-##1

3.14 System Resources Overload

3.14.1 1115 - UNABLE_TO_RUN_TEST FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: System Resources Overload Specific Problems: UNABLE_TO_RUN_TEST Severity: Warning Proposed Repair Actions:

No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 137 Activate Test Error description: The test cannot be performed due to insufficient system resources. That particular test ends without result.

0102 (D)= Test instance

0304 (D)= Nack cause.

Possible values:

0x1E = E_NC_PHISICAL_CONFIGURATION_CANNOT_BE_PERFORMED

0X1F = E_NC_TEST_NOT_INITIATED

0X97 = E_NC_MOT_NOT_LOCKED

0XC7 = E_NC_INVALID_WORKING_PHASE

0506 (D)= MOT mnemonic

0708 (D)= MOT address[0]

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##1115-##2

Page 97: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 97

##2001-##1

3.15 LAPD Link Protocol Failure

3.15.1 2001 - ASUB_TRANSIENT_FAILURE FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: COMMUNICATION FAILURE EVENT Probable Cause: LAPD Link Protocol Failure Specific Problems: ASUB_TRANSIENT_FAILURE Severity: Warning Proposed Repair Actions:

No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 32 BSC_LINKMNGR_TSK Error description: LAPD layer 2 manager on TRAU side has found and recovered a failure. There is the possibility of messages loss in the link between TRAU and BSC.

0102 (D)= not used

0304 (D)= not used

0506 (D)= not used

0708 (D)= not used

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##2001-##2

Page 98: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

98 A30808-X3247-M440-1-7619

##2003-##1

3.15.2 2003 - LPDL_LINK_DOWN FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: COMMUNICATION FAILURE EVENT Probable Cause: LAPD Link Protocol Failure Specific Problems: LPDL_LINK_DOWN Severity: Critical Proposed Repair Actions:

Check the LAPD parameters on both side Check on both sides the LAPD parameters (TEI, LAPD timeslot) and correct them, if necessary.

Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 32 BSC_LINKMNGR_TSK Error description: This error is generated in the following cases: - The timeslot used for LAPD on TRAU is not the same set on BSC - TRAU becames free running due to the loss of the syncronism coming from BSC - reception of a Layer 3 release indication - reception of a Layer 3 error The LAPD goes to disabled.

0102 (D)= Link status : 1 = established

0 = not established

0304 (D)= for internal use only

0506 (D)= TEI number

0708 (D)= Retry connection : 1 = LAPD connection request has been performed

0910 (D)= for internal use only

1112 (D)= 1 = TEI mismatch

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##2003-##2

Page 99: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 99

##15-##1

3.16 Remote alarm indication

3.16.1 15 - REMOTE_ALARM FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: COMMUNICATION FAILURE EVENT Probable Cause: Remote alarm indication Specific Problems: REMOTE_ALARM Severity: Major Proposed Repair Actions:

Check cables, connections, line quality Check the related cables, connections and line quality.

Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 39 PCM Device Controller Task Error description: A Remote alarm indication has been detected on a PCMS trunk without redundancy (the other trunk is NOT EQUIPPED or FAULTED) or on a PCMT line. This means that the other Network Entity (BSC/MSC) has decided to disable the line for some alarm on the PCM stream provided by TRAU. PCM Device Controller informs Status Manager Task about trunk faulted. The PCM line is put in disabled state.

0102 (S)= PCM line alarmed:

PCMT line 0 = 0

PCMT line 1 = 0x0001

PCMT line 2 = 0x0002

PCMT line 3 = 0x0003

PCMS trunk A = 0x000a

PCMS trunk B = 0x000b

0304 (D)= Alarm Type Identifier = 0x0002 (Line Alarm)

0506 (D)= Alarm value: it can be the OR of the following values:

AIS = 0x01

LCA = 0x02

RAI = 0x04

DTOM_EER = 0x08

LFA = 0x10

LOS = 0x20

0708 (D)= Persistent Alarm = 0x00aa

Alarm due to microinterruptions = 0x00cc

0910 (D)= not used

1112 (D)= not used

Page 100: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

100 A30808-X3247-M440-1-7619

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##15-##2

Page 101: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 101

##26-##1

3.16.2 26 - REMOTE_ALARM_ON_LINK_A FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: COMMUNICATION FAILURE EVENT Probable Cause: Remote alarm indication Specific Problems: REMOTE_ALARM_ON_LINK_A Severity: Minor Proposed Repair Actions:

Check cables, connections, line quality Check the related cables, connections and line quality.

Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 39 PCM Device Controller Task Error description: A Remote alarm indication has been detected on a PCMS trunk with redundancy (the other trunk is ENABLED or DEGRADED). This means that the other Network Entity (BSC/MSC) has decided to disable the line for some alarm on the PCM stream provided by TRAU. PCM Device Controller informs Status Manager Task about trunk faulted. If the trunk faulted was the active one, PCM Device Controller triggers the trunk switch: it enables the other PCMS trunk towards TRAC.

0102 (S)= PCM line alarmed:

PCMS trunk A = 0x000a

0304 (D)= Alarm Type Identifier = 0x0002 (Line Alarm)

0506 (D)= Alarm value: it can be the OR of the following values:

AIS = 0x01

LCA = 0x02

RAI = 0x04

DTOM_EER = 0x08

LFA = 0x10

LOS = 0x20

0708 (D)= Persistent Alarm = 0x00aa

Alarm due to microinterruptions = 0x00cc

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

Page 102: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

102 A30808-X3247-M440-1-7619

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##26-##2

Page 103: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 103

##27-##1

3.16.3 27 - REMOTE_ALARM_ON_LINK_B FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: COMMUNICATION FAILURE EVENT Probable Cause: Remote alarm indication Specific Problems: REMOTE_ALARM_ON_LINK_B Severity: Minor Proposed Repair Actions:

Check cables, connections, line quality Check the related cables, connections and line quality.

Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 39 PCM Device Controller Task Error description: A Remote alarm indication has been detected on a PCMS trunk with redundancy (the other trunk is ENABLED or DEGRADED). This means that the other Network Entity (BSC/MSC) has decided to disable the line for some alarm on the PCM stream provided by TRAU. PCM Device Controller informs Status Manager Task about trunk faulted. If the trunk faulted was the active one, PCM Device Controller triggers the trunk switch: it enables the other PCMS trunk towards TRAC.

0102 (S)= PCM line alarmed:

PCMS trunk B = 0x000b

0304 (D)= Alarm Type Identifier = 0x0002 (Line Alarm)

0506 (D)= Alarm value: it can be the OR of the following values:

AIS = 0x01

LCA = 0x02

RAI = 0x04

DTOM_EER = 0x08

LFA = 0x10

LOS = 0x20

0708 (D)= Persistent Alarm = 0x00aa

Alarm due to microinterruptions = 0x00cc

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

Page 104: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

104 A30808-X3247-M440-1-7619

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##27-##2

Page 105: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 105

##16-##1

3.17 Transmission Error

3.17.1 16 - HIGHER_BER_THRESHOLD_EXCEEDED FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: EQUIPMENT FAILURE EVENT Probable Cause: Transmission Error Specific Problems: HIGHER_BER_THRESHOLD_EXCEEDED Severity: Major Proposed Repair Actions:

Check cables, connections, line quality Check the related cables, connections and line quality.

Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 39 PCM Device Controller Task Error description: The Bit Error Rate has exceeded the higher threshold on a PCMS trunk without redundancy (the other trunk is NOT EQUIPPED or FAULTED) or on a PCMT line. PCM Device Controller informs Status Manager Task about trunk faulted. The PCM line is put in disable state.

0102 (S)= PCM line alarmed:

PCMT line 0 = 0

PCMT line 1 = 0x0001

PCMT line 2 = 0x0002

PCMT line 3 = 0x0003

PCMS trunk A = 0x000a

PCMS trunk B = 0x000b

0304 (D)= Alarm Type Identifier = 0x0003 (Error Rate Alarm)

0506 (D)= BER Value:10exp(-3) = 0xff

10exp(-4) = 0xdf

10exp(-5) = 0x9f

10exp(-6) = 0x1f

10exp(-7) = 0x1e

10exp(-8) = 0x1c

10exp(-9) = 0x18

0708 (D)= not used

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

Page 106: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

106 A30808-X3247-M440-1-7619

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##16-##2

Page 107: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 107

##17-##1

3.17.2 17 - LOWER_BER_THRESHOLD_EXCEEDED FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: QUALITY OF SERVICE FAILURE EVENT Probable Cause: Transmission Error Specific Problems: LOWER_BER_THRESHOLD_EXCEEDED Severity: Minor Proposed Repair Actions:

Check cables, connections, line quality Check the related cables, connections and line quality.

Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 39 PCM Device Controller Task Error description: It is valid for MSCI V2 only. The Bit Error Rate has gone beyond the threshold fixed by the operator on a PCMT line.PCM Device Controller informs Status Manager Task about trunk faulted. PCMT object is put in enabled/degraded state.

0102 (S)= PCM line alarmed:

PCMT line 0 = 0

PCMT line 1 = 0x0001

PCMT line 2 = 0x0002

PCMT line 3 = 0x0003

0304 (D)= Alarm Type Identifier = 0x0003 (Error Rate Alarm)

0506 (D)= BER Value (MSCI V2 only):

10exp(-3) = 0xff

10exp(-4) = 0xdf

10exp(-5) = 0x9f

10exp(-6) = 0x1f

10exp(-7) = 0x1e

10exp(-8) = 0x1c

10exp(-9) = 0x18

0708 (D)= not used

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

Page 108: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

108 A30808-X3247-M440-1-7619

2728 (D)= not used

2930 (D)= not used ##17-##2

Page 109: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 109

##28-##1

3.17.3 28 - HIGHER_BER_THRESHOLD_EXCEEDED_ON_LINK_A FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: COMMUNICATION FAILURE EVENT Probable Cause: Transmission Error Specific Problems: HIGHER_BER_THRESHOLD_EXCEEDED_ON_LINK_A Severity: Minor Proposed Repair Actions:

Check cables, connections, line quality Check the related cables, connections and line quality.

Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 39 PCM Device Controller Task Error description: A Higher BER Threshold Exceeded alarm has occurred on a PCMS trunk with redundancy (the other trunk is ENABLED or DEGRADED). PCM Device Controller informs Status Manager Task about trunk faulted. If the trunk faulted was the active one, PCM Device Controller triggers the trunk switch:it enables the others PCMS trunk towards TRAC.

0102 (S)= PCM line alarmed:

PCMS trunk A = 0x000a

0304 (D)= Alarm Type Identifier = 0x0003 (Error Rate Alarm)

0506 (D)= BER Value:

10exp(-3) = 0xff

10exp(-4) = 0xdf

10exp(-5) = 0x9f

10exp(-6) = 0x1f

10exp(-7) = 0x1e

10exp(-8) = 0x1c

10exp(-9) = 0x18

0708 (D)= not used

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used

Page 110: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

110 A30808-X3247-M440-1-7619

##28-##2

Page 111: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 111

##29-##1

3.17.4 29 - HIGHER_BER_THRESHOLD_EXCEEDED_ON_LINK_B FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: COMMUNICATION FAILURE EVENT Probable Cause: Transmission Error Specific Problems: HIGHER_BER_THRESHOLD_EXCEEDED_ON_LINK_B Severity: Minor Proposed Repair Actions:

Check cables, connections, line quality Check the related cables, connections and line quality.

Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 39 PCM Device Controller Task Error description: A Higher BER Threshold Exceeded alarm has occurred on a PCMS trunk with redundancy (the other trunk is ENABLED or DEGRADED). PCM Device Controller informs Status Manager Task about trunk faulted. If the trunk faulted was the active one, PCM Device Controller triggers the trunk switch:it enables the others PCMS trunk towards TRAC.

0102 (S)= PCM line alarmed:

PCMS trunk B = 0x000b

0304 (D)= Alarm Type Identifier = 0x0003 (Error Rate Alarm)

0506 (D)= BER Value:

10exp(-3) = 0xff

10exp(-4) = 0xdf

10exp(-5) = 0x9f

10exp(-6) = 0x1f

10exp(-7) = 0x1e

10exp(-8) = 0x1c

10exp(-9) = 0x18

0708 (D)= not used

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used

Page 112: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

112 A30808-X3247-M440-1-7619

##29-##2

Page 113: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 113

##30-##1

3.17.5 30 - LOWER_BER_THRESHOLD_EXCEEDED_ON_LINK_A FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: COMMUNICATION FAILURE EVENT Probable Cause: Transmission Error Specific Problems: LOWER_BER_THRESHOLD_EXCEEDED_ON_LINK_A Severity: Minor Proposed Repair Actions:

Check cables, connections, line quality Check the related cables, connections and line quality.

Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 39 PCM Device Controller Task Error description: It is valid for BSCI V4 only. A Lower BER Threshold Exceeded alarm has occurred on a PCMS trunk. PCM Device Controller informs Status Manager Task about trunk faulted. PCMS object is put in enabled/degraded state.

0102 (S)= PCM line alarmed:

PCMS trunk A = 0x000a

0304 (D)= Alarm Type Identifier = 0x0003 (Error Rate Alarm)

0506 (D)= BER Value: (BSCI V4 only)

10exp(-3) = 0xff

10exp(-4) = 0xdf

10exp(-5) = 0x9f

10exp(-6) = 0x1f

10exp(-7) = 0x1e

10exp(-8) = 0x1c

10exp(-9) = 0x18

0708 (D)= not used

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used

Page 114: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

114 A30808-X3247-M440-1-7619

##30-##2

Page 115: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 115

##31-##1

3.17.6 31 - LOWER_BER_THRESHOLD_EXCEEDED_ON_LINK_B FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: COMMUNICATION FAILURE EVENT Probable Cause: Transmission Error Specific Problems: LOWER_BER_THRESHOLD_EXCEEDED_ON_LINK_B Severity: Minor Proposed Repair Actions:

Check cables, connections, line quality Check the related cables, connections and line quality.

Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 39 PCM Device Controller Task Error description: It is valid for BSCI V4 only. A Lower BER Threshold Exceeded alarm has occurred on a PCMS trunk. PCM Device Controller informs Status Manager Task about trunk faulted. PCMS object is put in enabled/degraded state.

0102 (S)= PCM line alarmed:

PCMS trunk B = 0x000b

0304 (D)= Alarm Type Identifier = 0x0003 (Error Rate Alarm)

0506 (D)= BER Value: (BSCI V2 only)

10exp(-3) = 0xff

10exp(-4) = 0xdf

10exp(-5) = 0x9f

10exp(-6) = 0x1f

10exp(-7) = 0x1e

10exp(-8) = 0x1c

10exp(-9) = 0x18

0708 (D)= not used

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used

Page 116: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

116 A30808-X3247-M440-1-7619

##31-##2

Page 117: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 117

##1010-##1

4 ITU Probable Causes

4.1 Configuration Or Customization Error

4.1.1 1010 - HW_NOT_COMPATIBLE_WITH_INTERNAL_POWER FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Configuration Or Customization Error Specific Problems: HW_NOT_COMPATIBLE_WITH_INTERNAL_POWER Severity: Warning Proposed Repair Actions:

Check the configuration/HW compatibility Correct the configuration attribute value(s) for the addressed card(s) or replace the Hardware with one compatible with the configuration.

Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 38 Status Manager Notify Handler Error description: The card version is not compatible with the TRAU configuration (TypeOfTraue is WITHOUT_TPWR).

0102 (D)= not used

0304 (D)= not used

0506 (D)= not used

0708 (D)= not used

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##1010-##2

Page 118: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

118 A30808-X3247-M440-1-7619

##1032-##1

4.1.2 1032 - TRAC_HW_NOT_COMPATIBLE_WITH_ACTUAL_CONFIGURATION FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: COMMUNICATION FAILURE EVENT Probable Cause: Configuration Or Customization Error Specific Problems: TRAC_HW_NOT_COMPATIBLE_WITH_ACTUAL_CONFIGURATION Severity: Minor Proposed Repair Actions:

Check the configuration/HW compatibility Correct the configuration attribute value(s) for the addressed card(s) or replace the Hardware with one compatible with the configuration.

Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 27 TRAC Device Handler Error description: This error is generated when the TRAC HW is not able to manage a circuit pool required for a certain TSLA. Moreover, this failure is emitted when CTM service is enabled and the TRAC card have hardware version different from V7. TRAC card is put in disabled/failed state

0102 (D)= .code line number

0304 (D)= staus.

0506 (D)= waiting.

0708 (D)= flag.

0910 (D)= diag

1112 (D)= AAAA - fixed

1314 (S)= Trac instance

1516 (S)= Trac Hardware Version

1718 (D)= SWLoadHeader_file_version.

1920 (S)= Trau Type:

0xB: NO_AMR.

0xC: AMR

0xD: MIX AMR & NO_AMR

2122 (S)= VQE Status: 0=Disabled; 1=Enabled

2324 (S)= CTM Status: 0=Disabled; 1=Enabled

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##1032-##2

Page 119: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 119

##1036-##1

4.1.3 1036 - BSCI_HW_VERSION_NOT_VALID_FOR_PCM_TYPE FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: EQUIPMENT FAILURE EVENT Probable Cause: Configuration Or Customization Error Specific Problems: BSCI_HW_VERSION_NOT_VALID_FOR_PCM_TYPE Severity: Major Proposed Repair Actions:

Check the configuration/HW compatibility Correct the configuration attribute value(s) for the addressed card(s) or replace the Hardware with one compatible with the configuration.

Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 23 Data Base, 26 BSMS Device Handler Error description: The BSCI card doesn't allow the PCMTYPE attribute value. If the BSCI is active the BSMS restart using the default setting for the PCMTYPE attribute. If the BSCI is standby the BSMS goes into disabled failed state.

0102 (D)= not used

0304 (D)= not used

0506 (D)= not used

0708 (D)= not used

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##1036-##2

Page 120: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

120 A30808-X3247-M440-1-7619

##1038-##1

4.1.4 1038 - MSCI_HW_VERSION_NOT_VALID_FOR_PCM_TYPE FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: EQUIPMENT FAILURE EVENT Probable Cause: Configuration Or Customization Error Specific Problems: MSCI_HW_VERSION_NOT_VALID_FOR_PCM_TYPE Severity: Major Proposed Repair Actions:

Check the configuration/HW compatibility Correct the configuration attribute value(s) for the addressed card(s) or replace the Hardware with one compatible with the configuration.

Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 23 Data Base, 26 BSMS Device Handler Error description: The MSCI card doesn't allow the PCMTYPE attribute value. If the MSCI is active the BSMS restart using the default setting for the PCMTYPE attribute. If the MSCI is standby the BSMS goes into disabled failed state.

0102 (D)= error code:

COMDH_ER_PCM24MSCIHW_INCONS 123

0304 (D)= signal type

0506 (D)= signal subtype

0708 (D)= not used

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##1038-##2

Page 121: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 121

##1103-##1

4.1.5 1103 - TPWR_OFFREQUEST_PENDING FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Configuration Or Customization Error Specific Problems: TPWR_OFFREQUEST_PENDING Severity: Warning Proposed Repair Actions:

Lock the related equipment Lock the related equipment. Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 38 Status Manager Notify Handler Error description: A power off request is pending. The TPWR will be switched off when it will be locked.

0102 (D)= Object Class.

0304 (D)= Object mnemonic.

0506 (D)= Object instance.

0708 (D)= 0xffff

0910 (D)= Case discriminator.

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##1103-##2

Page 122: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

122 A30808-X3247-M440-1-7619

##1116-##1

4.1.6 1116 - TRAC_HW_NOT_COMPATIBLE_WITH_VQE FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Configuration Or Customization Error Specific Problems: TRAC_HW_NOT_COMPATIBLE_WITH_VQE Severity: Warning Proposed Repair Actions:

Check the configuration/HW compatibility Correct the configuration attribute value(s) for the addressed card(s) or replace the Hardware with one compatible with the configuration.

Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 27 TRAC Device Handler Error description: This warning is emitted to inform operator that VQE service isn't avaible for those TRACs with HW version different from V7. Note: The FER TRAC_HW_NOT_COMPATIBLE_WITH_VQE is emitted on local TRAU LMT only. The severity is WARNING, and then there isn't any alarm enqueuing. On BSC side, the information about compability between VQE service and TRAC hw version is available using GETINFO TRAU command.

0102 (D)= line code

0304 (D)= staus..

0506 (D)= waiting.

0708 (D)= flag.

0910 (D)= diag

1112 (S)= TRAC instance

1314 (S)= TRAC Hardware Version.

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##1116-##2

Page 123: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 123

##2002-##1

4.1.7 2002 - UNEXPECTED_TEI FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: COMMUNICATION FAILURE EVENT Probable Cause: Configuration Or Customization Error Specific Problems: UNEXPECTED_TEI Severity: Critical Proposed Repair Actions:

Check the LAPD parameters on both side Check on both sides the LAPD parameters (TEI, LAPD timeslot) and correct them, if necessary.

Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 32 BSC_LINKMNGR_TSK Error description: TRAU has been configured with wrong TEI: PPLD has accepted the LAPD establishment but, from TDPC viewpoint, a LAPD with TEI X has been established on PCMS Y (X != Y). This LAPD can't be used for O&M purposes, BSC sends periodically on it an "unexpected TEI id" message. The LAPD goes to disabled state.

0102 (D)= not used

0304 (D)= not used

0506 (D)= not used

0708 (D)= not used

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##2002-##2

Page 124: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

124 A30808-X3247-M440-1-7619

##1098-##1

4.2 Congestion

4.2.1 1098 - T_INTERFACE_MESSAGE_LOST FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Congestion Specific Problems: T_INTERFACE_MESSAGE_LOST Severity: Warning Proposed Repair Actions:

No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 22 LMT_IO_COLL_TSK Error description: LMT layer 2 software on TRAU isn't able to send further messages toward LMT (output buffer full or "RNR" frame received from LMT). Output section of LMT layer 2 tx software is re-started (buffer is flushed, transmission task is deleted by LMT layer 3 collector task and re-created by abort handler). A certain number of messages toward LMT are lost.

0102 (D)= not used

0304 (D)= not used

0506 (D)= not used

0708 (D)= not used

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##1098-##2

Page 125: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 125

##1083-##1

4.3 Corrupt Data

4.3.1 1083 - FLASH_EPROM_MUST_BE_FORMATTED FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Corrupt Data Specific Problems: FLASH_EPROM_MUST_BE_FORMATTED Severity: Major Proposed Repair Actions:

Format the BSCI Flash EPROM Format the Flash EPROM of the concerned BSCI card. Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 23 Data Base, 28 DOWNLOAD_TSK, 29 PERIPH_LOAD_TSK, 40 CROSSCOPY_TSK Error description: The Flash Eprom is corrupted. The BSMS is put in disabled failed state. System action: Originator = 23 Operation refused Originator = 28 Downloading aborted. If the error occurs during the System initialization, the Flash Eprom is formatted. Originator = 29 Peripheral loading aborted Originator = 40 Crosscopying aborted

0102 (D)= kind of File system used:

FAFS = 1

SLFS = 2

0304 (D)= File system function called:

OPEN = 1

READ = 2

WRITE = 3

CLOSE = 4

ERASE = 5

SWCOMPL = 6

SWSTATUS = 7

FORMAT = 8

DIR = 9

DBREN = 10

Page 126: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

126 A30808-X3247-M440-1-7619

0506 (D)= File System error:

FLASH MUST BE FORMATTED = 14

0708 (D)= file name first letter (ASCII code)

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##1083-##2

Page 127: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 127

##1108-##1

4.3.2 1108 - FORMATTING_FLASH_EPROM FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Corrupt Data Specific Problems: FORMATTING_FLASH_EPROM Severity: Major Proposed Repair Actions:

No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 26 BSMS Device Handler Error description: A previously Locked BSMS is formatting its Flash Eprom. The BSMS copy remains in disabled state.

0102 (D)= signal type

0304 (D)= signal subtype

0506 (D)= not used

0708 (D)= not used

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##1108-##2

Page 128: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

128 A30808-X3247-M440-1-7619

##1109-##1

4.3.3 1109 - INVALID_FILE_FORMAT FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Corrupt Data Specific Problems: INVALID_FILE_FORMAT Severity: Warning Proposed Repair Actions:

No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 29 PERIPH_LOAD_TSK Error description: The loading of a MSCI/TRAC card has been aborted because of a wrong record format. The loading abort of MSCI active card causes the switch of the BSMS configuration or the reset of the BSMS active, if the standby is not available. The loading abort of MSCI standby card cuses the reset of the BSMS standby. The loading abort of a TRAC card reinitializes the procedure; if the maximum attempts number is reached, the card is disabled.

0102 (D)= code statement number(the module is identified)

0304 (D)= error type or parameter value

0506 (D)= link (card) identifier: 00-05 TRAC 0-5

06 MSCI

0708 (D)= processor identifier(meaningful for TRAC cards):

00 Trac controller

01 Dsp

0910 (D)= last transmitted packet

1112 (D)= FSM state value

1314 (D)= Source system of received message

1516 (D)= Signal type of received message

1718 (D)= Signal subtype of received message

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used

Originator: 48 RI Task

Error description:

Page 129: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 129

The nob-RIU file has an invalid size. The sum of the ob-RIU part and of the nob-RIU part cannot exceed 4K. The nob-RIU part is trunkated.

0102 (D)= code statement number(the module is identified)

0304 (D)= not used

0506 (D)= not used

0708 (D)= not used

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##1109-##2

Page 130: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

130 A30808-X3247-M440-1-7619

##5001-##1

4.4 Enclosure Door Open

4.4.1 5001 - OPEN_DOOR_ALARM FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: ENVIRONMENTAL FAILURE EVENT Probable Cause: Enclosure Door Open Specific Problems: OPEN_DOOR_ALARM Severity: Critical Proposed Repair Actions:

See the foreseen operating company repair action Environmental alarm. The repair action is defined by the operating company.

Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 47 DC ENVA TSK Error description: The alarm persistency sensed by the Scan Work Function which polls the ENVA sense point on the BSCI card has reached the threshold fixed by the operator.

0102 (D)= for internal use only

0304 (D)= for internal use only

0506 (D)= ENVA instance = 0

0708 (D)= Threshold

0910 (D)= Counter

1112 (D)= Name of the ENVA

1314 (D)= Scan Work Function FLAG:

Disabled = 0

Enabled = 1

1516 (D)= Interface logic

Negative Logic = 0

Positive Logic = 1

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##5001-##2

Page 131: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 131

##13-##1

4.5 Loss Of Frame

4.5.1 13 - LOSS_OF_FRAME_ALIGNMENT FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: COMMUNICATION FAILURE EVENT Probable Cause: Loss Of Frame Specific Problems: LOSS_OF_FRAME_ALIGNMENT Severity: Major Proposed Repair Actions:

Check cables, connections, line quality Check the related cables, connections and line quality.

Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 39 PCM Device Controller Task Error description: The Frame Alignment has been lost on a PCMS trunk without redundancy (the other trunk is NOT EQUIPPED or FAULTED) or on a PCMT line. PCM Device Controller informs Status Manager Task about trunk faulted. The PCM line is put in disabled state.

0102 (S)= PCM line alarmed:

PCMT line 0 = 0

PCMT line 1 = 0x0001

PCMT line 2 = 0x0002

PCMT line 3 = 0x0003

PCMS trunk A = 0x000a

PCMS trunk B = 0x000b

0304 (D)= Alarm Type Identifier = 0x0002 (Line Alarm)

0506 (D)= Alarm value: it can be the OR of the following values:

AIS = 0x01

LCA = 0x02

RAI = 0x04

DTOM_EER = 0x08

LFA = 0x10

LOS = 0x20

0708 (D)= Persistent Alarm = 0x00aa

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

Page 132: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

132 A30808-X3247-M440-1-7619

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##13-##2

Page 133: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 133

##14-##1

4.5.2 14 - LOSS_OF_CRC_ALIGNMENT FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: COMMUNICATION FAILURE EVENT Probable Cause: Loss Of Frame Specific Problems: LOSS_OF_CRC_ALIGNMENT Severity: Major Proposed Repair Actions:

Check cables, connections, line quality Check the related cables, connections and line quality.

Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 39 PCM Device Controller Task Error description: A Loss of CRC Alignment alarm has occurred on a PCMS trunk without redundancy (the other trunk is NOT EQUIPPED or FAULTED) or on a PCMT line. PCM Device Controller informs Status Manager Task about trunk faulted. The PCM line is put in disabled state.

0102 (S)= PCM line alarmed:

PCMT line 0 = 0

PCMT line 1 = 0x0001

PCMT line 2 = 0x0002

PCMT line 3 = 0x0003

PCMS trunk A = 0x000a

PCMS trunk B = 0x000b

0304 (D)= Alarm Type Identifier = 0x0002 (Line Alarm)

0506 (D)= Alarm value: it can be the OR of the following values:

AIS = 0x01

LCA = 0x02

RAI = 0x04

DTOM_EER = 0x08

LFA = 0x10

LOS = 0x20

0708 (D)= Persistent Alarm = 0x00aa

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

Page 134: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

134 A30808-X3247-M440-1-7619

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##14-##2

Page 135: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 135

##22-##1

4.5.3 22 - LOSS_OF_FRAME_ALIGNMENT_ON_LINK_A FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: COMMUNICATION FAILURE EVENT Probable Cause: Loss Of Frame Specific Problems: LOSS_OF_FRAME_ALIGNMENT_ON_LINK_A Severity: Minor Proposed Repair Actions:

Check cables, connections, line quality Check the related cables, connections and line quality.

Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 39 PCM Device Controller Task Error description: The frame Alignment has been lost on a PCMS trunk with redundancy (the other trunk is ENABLED or DEGRADED). PCM Device Controller informs Status Manager Task about trunk faulted. If the trunk faulted is the active one, PCM Device Controller triggers the trunk switch: it enables the oter PCMS trunk towards TRAC.

0102 (S)= PCM line alarmed:

PCMS trunk A = 0x000a

0304 (D)= Alarm Type Identifier = 0x0002 (Line Alarm)

0506 (D)= Alarm value: it can be the OR of the following values:

AIS = 0x01

LCA = 0x02

RAI = 0x04

DTOM_EER = 0x08

LFA = 0x10

LOS = 0x20

0708 (D)= Persistent Alarm = 0x00aa

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##22-##2

Page 136: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

136 A30808-X3247-M440-1-7619

##23-##1

4.5.4 23 - LOSS_OF_FRAME_ALIGNMENT_ON_LINK_B FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: COMMUNICATION FAILURE EVENT Probable Cause: Loss Of Frame Specific Problems: LOSS_OF_FRAME_ALIGNMENT_ON_LINK_B Severity: Minor Proposed Repair Actions:

Check cables, connections, line quality Check the related cables, connections and line quality.

Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 39 PCM Device Controller Task Error description: The frame Alignment has been lost on a PCMS trunk with redundancy (the other trunk is ENABLED or DEGRADED). PCM Device Controller informs Status Manager Task about trunk faulted. If the trunk faulted is the active one, PCM Device Controller triggers the trunk switch: it enables the oter PCMS trunk towards TRAC.

0102 (S)= PCM line alarmed:

PCMS trunk B = 0x000b

0304 (D)= Alarm Type Identifier = 0x0002 (Line Alarm)

0506 (D)= Alarm value: it can be the OR of the following values:

AIS = 0x01

LCA = 0x02

RAI = 0x04

DTOM_EER = 0x08

LFA = 0x10

LOS = 0x20

0708 (D)= Persistent Alarm = 0x00aa

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##23-##2

Page 137: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 137

##24-##1

4.5.5 24 - LOSS_OF_CRC_ALIGNMENT_ON_LINK_A FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: COMMUNICATION FAILURE EVENT Probable Cause: Loss Of Frame Specific Problems: LOSS_OF_CRC_ALIGNMENT_ON_LINK_A Severity: Minor Proposed Repair Actions:

Check cables, connections, line quality Check the related cables, connections and line quality.

Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 39 PCM Device Controller Task Error description: A Loss of CRC Alignment alarm has occurred on a PCMS trunk with redundancy (the other trunk is ENABLED or DEGRADED). PCM Device Controller informs Status Manager Task about trunk faulted. If the trunk faulted is the active one, PCM Device Controller triggers the trunk switch: it enables the oter PCMS trunk towards TRAC.

0102 (S)= PCM line alarmed:

PCMS trunk A = 0x000a

0304 (D)= Alarm Type Identifier = 0x0002 (Line Alarm)

0506 (D)= Alarm value: it can be the OR of the following values:

AIS = 0x01

LCA = 0x02

RAI = 0x04

DTOM_EER = 0x08

LFA = 0x10

LOS = 0x20

0708 (D)= Persistent Alarm = 0x00aa

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##24-##2

Page 138: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

138 A30808-X3247-M440-1-7619

##25-##1

4.5.6 25 - LOSS_OF_CRC_ALIGNMENT_ON_LINK_B FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: COMMUNICATION FAILURE EVENT Probable Cause: Loss Of Frame Specific Problems: LOSS_OF_CRC_ALIGNMENT_ON_LINK_B Severity: Minor Proposed Repair Actions:

Check cables, connections, line quality Check the related cables, connections and line quality.

Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 39 PCM Device Controller Task Error description: A Loss of CRC Alignment has occurred on a PCMS trunk with redundancy (the other trunk is ENABLED or DEGRADED). PCM Device Controller informs Status Manager Task about trunk faulted. If the trunk faulted is the active one, PCM Device Controller triggers the trunk switch: it enables the oter PCMS trunk towards TRAC.

0102 (S)= PCM line alarmed:

PCMS trunk B = 0x000b

0304 (D)= Alarm Type Identifier = 0x0002 (Line Alarm)

0506 (D)= Alarm value: it can be the OR of the following val:

AIS = 0x01

LCA = 0x02

RAI = 0x04

DTOM_EER = 0x08

LFA = 0x10

LOS = 0x20

0708 (D)= Persistent Alarm = 0x00aa

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##25-##2

Page 139: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 139

##1040-##1

4.6 Out Of Memory

4.6.1 1040 - MEMORY_NOT_AVAILABLE FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Out Of Memory Specific Problems: MEMORY_NOT_AVAILABLE Severity: Warning Proposed Repair Actions:

No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 16 Power Supply Device Controller, 19 IPC Dispatcher, 20 IPC Link Maneger, 21 LMT_IO_DLM_TSK, 22 LMT_IO_COLL_TSK, 27 TRAC Device Handler, 28 DOWNLOAD_TSK, 32 BSC_LINKMNGR_TSK, 40 CROSSCOPY_TSK, 114 TRAC fault detection

Error description: No memory was available as a result of the buffer allocation request Case of originator: 21, 22 and 32

0102 (D)= RTE message pool number [7..10]

0304 (D)= not used

0506 (D)= not used

0708 (D)= not used

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##1040-##2

Page 140: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

140 A30808-X3247-M440-1-7619

##1041-##1

4.6.2 1041 - MAILBOX_CANNOT_BE_CREATED FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Out Of Memory Specific Problems: MAILBOX_CANNOT_BE_CREATED Severity: Warning Proposed Repair Actions:

No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 18 IPC_COLLECTOR_TSK, 23 Data Base, 24 SM_COMM_TSK Error description: The Operating System limit has been reached. If the Originator is Database (23) a system reset will be executed. This means that if the BSMS is in duplex configuration a copy switch occurs, otherwise a Bring Up is performed.

0102 (D)= not used

0304 (D)= not used

0506 (D)= not used

0708 (D)= not used

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##1041-##2

Page 141: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 141

##1093-##1

4.6.3 1093 - EMPTY_RTE_POOL_RESTART FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Out Of Memory Specific Problems: EMPTY_RTE_POOL_RESTART Severity: Warning Proposed Repair Actions:

No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 123 RTE_ORIGINATOR Error description: One or more RTE+ operating system pools has been found empty. The Number of overflow events for that pool has exceeded the corresponding value in THRESHOLD_TAB.

0102 (D)= RTE+ pool number

0304 (D)= not used

0506 (D)= not used

0708 (D)= not used

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##1093-##2

Page 142: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

142 A30808-X3247-M440-1-7619

##1094-##1

4.6.4 1094 - EMPTY_MESSAGE_POOL FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Out Of Memory Specific Problems: EMPTY_MESSAGE_POOL Severity: Warning Proposed Repair Actions:

No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 23 Data Base Error description: A message cannot be allocated. When not even the error notification message can be allocated, a system reset is performed.

0102 (D)= not used

0304 (D)= not used

0506 (D)= not used

0708 (D)= not used

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##1094-##2

Page 143: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 143

##1113-##1

4.6.5 1113 - MEMORY_OVERFLOW FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Out Of Memory Specific Problems: MEMORY_OVERFLOW Severity: Warning Proposed Repair Actions:

No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 123 RTE_ORIGINATOR Error description: A memory management error has been detected by the RTE+ operating system.

0102 (D)= 000b: a memory overflow has been detected

000c: a bad memory address has been detected

000d: a message overflow has been detected

0304 (D)= not used

0506 (D)= not used

0708 (D)= not used

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##1113-##2

Page 144: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

144 A30808-X3247-M440-1-7619

##1016-##1

4.7 Software Error

4.7.1 1016 - AR_PROCEDURAL_ERROR FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Software Error Specific Problems: AR_PROCEDURAL_ERROR Severity: Warning Proposed Repair Actions:

No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 25 Alarm Reporting Error description: In the Alarm Reporting area an error occoured due to internal data mismatch or system call with the wrong return value. Tipically this error arises after receiving the Get Alarm Event Condition message. The running procedure will be aborted.

0102 (D)= Source code line executed after calling error collector

0304 (D)= System error or internal error

1 = System error

2 = Memory not available

3 = Internal error

0506 (D)= When filled the last source lines executed are shown

0708 (D)= When filled the last source lines executed are shown

0910 (D)= When filled the last source lines executed are shown

1112 (D)= When filled the last source lines executed are shown

1314 (D)= When filled the last source lines executed are shown

1516 (D)= When filled the last source lines executed are shown

1718 (D)= When filled the last source lines executed are shown

1920 (D)= When filled the last source lines executed are shown

2122 (D)= When filled the last source lines executed are shown

2324 (D)= When filled the last source lines executed are shown

2526 (D)= When filled the last source lines executed are shown

2728 (D)= When filled the last source lines executed are shown

2930 (D)= When filled the last source lines executed are shown ##1016-##2

Page 145: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 145

##1017-##1

4.7.2 1017 - RTE_INTERRUPT_LOOP FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Software Error Specific Problems: RTE_INTERRUPT_LOOP Severity: Warning Proposed Repair Actions:

No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 123 RTE_ORIGINATOR Error description: An interrupt handler is called continously as a result of a persistent interrupt, without releasing CPU control to the RTE+ operating system scheduler. After 4 interrupt loops, the RTE+ operating system performs a system initialization (with copy switch).

0102 (D)= not used

0304 (D)= not used

0506 (D)= not used

0708 (D)= not used

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##1017-##2

Page 146: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

146 A30808-X3247-M440-1-7619

##1018-##1

4.7.3 1018 - STANDBY_ALIGNMENT_FAILED FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Software Error Specific Problems: STANDBY_ALIGNMENT_FAILED Severity: Warning Proposed Repair Actions:

No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 35 Alignment Service Task Error description: The alignment of the stand-by BSCI has failed

0102 (D)= 'C' statement number

0304 (D)= FSM state value

0506 (D)= source system of received message

0708 (D)= source mailbox of received message

0910 (D)= signal type of received message

1112 (D)= signal subtype of received message

1314 (D)= data length of received message

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##1018-##2

Page 147: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 147

##1034-##1

4.7.4 1034 - SCHEDULER_BLOCKED FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Software Error Specific Problems: SCHEDULER_BLOCKED Severity: Warning Proposed Repair Actions:

No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 123 RTE_ORIGINATOR Error description: The internal scheduler audit has found that a task is consuming real time in such a way to prevent other task from running. The additional info specify which scheduling queue is blocked.

0102 (D)= 37, prime time queue

0304 (D)= 38, spare time queue

0506 (D)= not used

0708 (D)= not used

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##1034-##2

Page 148: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

148 A30808-X3247-M440-1-7619

##1035-##1

4.7.5 1035 - INITIALIZATION_UPDATED FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Software Error Specific Problems: INITIALIZATION_UPDATED Severity: Warning Proposed Repair Actions:

No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 123 RTE_ORIGINATOR Error description: The internal scheduler audit has found too many initialization of the same time and has changed the initialization level according to the additional info values:

0102 (D)= 34, from full init to spare task init

0304 (D)= 35, from prime task to full init

0506 (D)= 36, from spare task to prime task init

0708 (D)= not used

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##1035-##2

Page 149: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 149

##1043-##1

4.7.6 1043 - INITIALIZATION_FAILURE FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Software Error Specific Problems: INITIALIZATION_FAILURE Severity: Warning Proposed Repair Actions:

No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 28 DOWNLOAD_TSK Error description: Download task initialization in dedicated time failure.

0102 (D)= kind of error:

FILE SYSTEM ERROR = 1

FLASH MUST BE FORMATTED = 2

MEMORY ALLOCATION ERROR = 3

UNEXPECTED FILE ERROR = 4

MESSAGE SENDING ERROR = 5

0304 (D)= not used

0506 (D)= not used

0708 (D)= not used

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used

Originator: 121 HSCX Init Handler

Error description: It was not possible to initialize the BSCI card IPC services at initialization time, which may cause more severe errors.

0102 (D)= not used

Page 150: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

150 A30808-X3247-M440-1-7619

0304 (D)= not used

0506 (D)= not used

0708 (D)= not used

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##1043-##2

Page 151: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 151

##1046-##1

4.7.7 1046 - FILE_SYSTEM_ERROR FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Software Error Specific Problems: FILE_SYSTEM_ERROR Severity: Warning Proposed Repair Actions:

No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 23 Data Base, 28 DOWNLOAD_TSK, 29 PERIPH_LOAD_TSK, 36 FAFS_COMPACTION_TASK, 40 CROSSCOPY_TSK, 48 RI Task

Error description: An attempt to access to the Flash Eprom was failed. System action: Originator = 23 Operation refused Originator = 28 Downloading aborted Originator = 29 Peripheral loading aborted Originator = 23 Crosscopy aborted Originator = 36 Compaction procedure problems

0102 (D)= kind of File system used:

FAFS = 1

SLFS = 2

if originator is 36,

this word means :module line where the error occurred.

0304 (D)= File system function called:

OPEN = 1

READ = 2

WRITE = 3

CLOSE = 4

ERASE = 5

SWCOMPL = 6

SWSTATUS = 7

FORMAT = 8

DIR = 9

DBREN = 10

Page 152: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

152 A30808-X3247-M440-1-7619

if originator is = 36,

this word means:

FLASH_NOT_VALID 1

NOT_ENOUGH_ROOM 2

NOT_ENOUGH_DESCRIPTOR 3

CRC_NOT_VALID 4

FILE_DOES_NOT_EXIST 5

FILE_SYSTEM_BUSY 6

FILE_ALREADY_CLOSED 7

FILE_NOT_OPENED_FOR_WRITE_OR_APPEND 8

FILE_NOT_OPENED_FOR_READ 9

FLASH_ALREADY_FULL 10

WRONG_OPEN_MODE 11

WRONG_FILE_VERSION 12

WRONG_PARAMETER 13

FLASH_MUST_BE_FORMATTED 14

NOT_OWNER 15

SLFS_MALLOC_FAILED 16

FAFS_MALLOC_FAILED 20

FAFS_WRONG_FILE_NAME 21

FAFS_COMPACT_IN_PRG 22

FAFS_FILE_IN_USE 23

FAFS_FILE_CORRUPTED 24

FAFS_INTERNAL_ERR 25

FAFS_FILE_TOO_LARGE 26

0506 (D)= File system error number:

FLASH NOT VALID = 1

NOT ENOUGH ROOM = 2

NOT ENOUGH DESCRIPTOR = 3

CRC NOT VALID = 4

FILE DOES NOT EXIST = 5

FILE SYSTEM BUSY = 6

FILE CLOSED = 7

FILE NOT OPENED = 8

FILE NOT OPENED FOR READ = 9

FLASH FULL = 10

WRONG OPEN MODE = 11

WRONG FILE VERSION = 12

WRONG PARAMETER = 13

FLASH MUST BE FORMATTED = 14

NOT OWNER = 15

FAFS MALLOC FAILED = 20

FAFS WRONG FILE NAME = 21

FAFS COMPACT IN PROGRESS = 22

FAFS FILE_IN USE = 23

FAFS FILE CORRUPTED = 24

Page 153: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 153

FAFS INTERNAL ERROR = 25

FILE TOO LARGE = 26

GENERIC WRITE ERROR = 0x0100

FLASH EPROM FSM TIMEOUT = 0x0200

UNSUCCESSFUL ERASING FLASH EPROM BLOCK = 0x0300

WRONG OPERATION SEQUENCE IN FLASH ACCESSING = 0x0400

FLASH EPROM INTERNAL WRITE ERROR = 0x1000

MAX ATTEMPT OF WRITING RETRY = 0x2000

WRITE ERROR DATA MISMATCH = 0x3000

WRITE ERROR CELL ALREADY WRITTEN = 0x4000

0708 (D)= file name first letter (ASCII code)

0910 (D)= COMPACT IN PROGRESS = 1 (for internal use only)

COMPACT NOT IN PROGRESS = 0 (for internal use only)

1112 (D)= WRITE LOCKED = 1 (for internal use only)

NOT WRITE LOCKED = 0 (for internal use only)

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##1046-##2

Page 154: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

154 A30808-X3247-M440-1-7619

##1049-##1

4.7.8 1049 - INTERNAL_LINK_FAILURE FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: COMMUNICATION FAILURE EVENT Probable Cause: Software Error Specific Problems: INTERNAL_LINK_FAILURE Severity: Warning Proposed Repair Actions:

No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 18 IPC_COLLECTOR_TSK Error description: An error occurred while trying to dispatch a message from the BSCI card toward another card (BSCI, TRAC or MSCI) using the internal link IPC. This error means that one message has been discarded as a result of: - link not established - no buffer available for sending after a requeuing retry - internal errors The exact cause can be determined according to the additional info values

0102 (D)= Source line of the file osiccl.c where the error occurred

0304 (D)= Internal link number (0..5 TRAC, 6 MSCI, 7 BSCI other copy)

0506 (D)= Internal link manager error code

0708 (D)= not used

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##1049-##2

Page 155: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 155

##1053-##1

4.7.9 1053 - BSMS_PROCEDURAL_ERROR FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Software Error Specific Problems: BSMS_PROCEDURAL_ERROR Severity: Major Proposed Repair Actions:

Test the addressed card(s) Test the addressed card(s) and perform the proper action according to the Test Result. Possibly, check also its (their) insertion in the frame.

Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 26 BSMS Device Handler Error description: A BSMS reconfiguration procedure has failed. The BSMS is put disabled failed.

0102 (D)= error code

0304 (D)= signal type

0506 (D)= signal subtype

0708 (D)= shutdowned tasks - high part (meaningless if = FFFF)

0910 (D)= shutdowned tasks - low part (meaningless if = FFFF)

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##1053-##2

Page 156: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

156 A30808-X3247-M440-1-7619

##1068-##1

4.7.10 1068 - TIMER_CANNOT_BE_SET FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Software Error Specific Problems: TIMER_CANNOT_BE_SET Severity: Warning Proposed Repair Actions:

No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 24 SM_COMM_TSK, 32 BSC_LINKMNGR_TSK Error description: Error calling the RTE System Call 'd_timer'. An error in the parameter passed at the System Call has occurred.

0102 (D)= Timer Number.

0304 (D)= Timer Value.

0506 (D)= Timer Unit.

0708 (D)= not used

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used

Originator: 23 Data Base

Error description: Error calling the RTE System Call 'd_timer'. An error in the parameter passed at the System Call has occurred. A system reset will be executed. This means that: - if the BSMS is in duplex configuration a copy switch occurs, otherwise a Bring Up is performed

0102 (D)= not used

0304 (D)= not used

Page 157: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 157

0506 (D)= not used

0708 (D)= not used

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##1068-##2

Page 158: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

158 A30808-X3247-M440-1-7619

##1084-##1

4.7.11 1084 - STANDBY_NOT_ALIGNED FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Software Error Specific Problems: STANDBY_NOT_ALIGNED Severity: Warning Proposed Repair Actions:

No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 23 Data Base, 38 Status Manager Notify Handler Error description: An updating or an alignment procedure is failed: the standby BSMS is not aligned; the standby status remains COLD STANDBY. An alignment procedure is attemptedup to three times. The alignment procedure is successful when the standby status becomes HOT STANDBY.

0102 (D)= line code

0304 (D)= not used

0506 (D)= not used

0708 (D)= not used

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##1084-##2

Page 159: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 159

##1099-##1

4.7.12 1099 - RTE_AUDIT_ERROR FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Software Error Specific Problems: RTE_AUDIT_ERROR Severity: Warning Proposed Repair Actions:

No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 123 RTE_ORIGINATOR Error description: An internal RTE+ operating system audit has reported some problems

0102 (D)= 0018: a message audit error has occurred, the error reports the lost messages or the bad

messages found by the internal audit

0019: a mailbox audit error has occurred, in this case 0304 = the number of bad mailboxes

found (HEX)

001A: a task audit error has occurred, in this case 0304 = the number of bad TCBs found

(HEX)

001B: a scheduler audit error has occurred

0020: an interrupt looop error has occurred. One interrupt has been served multiple times

without releasing CPU control to the scheduler

0304 (D)= the number of bad mailboxes found (HEX) or the number of bad TCBs found (HEX)

0506 (D)= not used

0708 (D)= not used

0910 (D)= not used

1112 (D)= not used

1314 (D)= not used

1516 (D)= not used

1718 (D)= not used

1920 (D)= not used

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##1099-##2

Page 160: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

160 A30808-X3247-M440-1-7619

##1107-##1

4.7.13 1107 - BSCI_RESET_CAUSE FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Software Error Specific Problems: BSCI_RESET_CAUSE Severity: Warning Proposed Repair Actions:

No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 111 BSMS Fault Detection Error description: The BSCI has been reset and initialized.

0102 (D)= object class identifier see Asub coding

0304 (D)= mnemonic see Asub coding

0506 (D)= object instance

0708 (D)= error identifier

0910 (D)= reset originator

1112 (D)= reserved to reset originator

1314 (D)= reserved to reset originator

1516 (D)= reserved to reset originator

1718 (D)= reserved to reset originator

1920 (D)= reserved to reset originator

2122 (D)= reserved to reset originator

2324 (D)= reserved to reset originator

2526 (D)= reserved to reset originator

2728 (D)= reserved to reset originator

2930 (D)= reserved to reset originator

Notes: if 0102 = FFFF, the error identifier is proprietary to the originator

if all additional info are 0000, the cause is the power off

if all additional info are F0F0, the cause is the hw reset

if 0910 = BLOADER ORIGINATOR (7C) 0708 can be:

BSCI WDT TIMEOUT = 4

FILE SYSTEM ERROR = 46

if 0708 = FILE_SYSTEM_ERROR 1112 can be:

FLASH NOT VALID = 1

NOT ENOUGH ROOM = 2

NOT ENOUGH DESCRIPTOR = 3

Page 161: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 161

CRC NOT VALID = 4

FILE DOES NOT EXIST = 5

FILE SYSTEM BUSY = 6

FILE CLOSED = 7

FILE NOT OPENED = 8

FILE NOT OPENED FOR READ = 9

FLASH FULL = 10

WRONG OPEN MODE = 11

WRONG FILE VERSION = 12

WRONG PARAMETER = 13

FLASH MUST BE FORMATTED = 14

if FLASH MUST BE FORMATTED 1314 can be:

FLASH NOT VALID = 1

FILE_SYSTEM_BUSY = 6

FLASH HAS BEEN FORMATTED = 83

BSCI NOT FOUND in FLASH = 84

NOT OWNER = 15

WRITE ERROR = 100 (byte write,read back failed)

VPP = 101 (VPP missing status reg. error)

BWS = 102 (byte write status reg. error)

VPP and BWS = 103

ES = 104 (erase status reg. error)

VPP and ES = 105

ES and BWS = 106

VPP, BWS and ES = 107

OPERATION TIMEOUT = 200

ERASE ERROR = 300

COMMAND SEQUENCE ERROR = 400

EOF_WITHOUT_END_RECORD = 80

BAD_RECORD_CHECKSUM = 81

BAD_RECORD_FORMAT = 82 ##1107-##2

Page 162: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

162 A30808-X3247-M440-1-7619

##1110-##1

4.7.14 1110 - PERIPHERAL_LOADING_ERROR FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Software Error Specific Problems: PERIPHERAL_LOADING_ERROR Severity: Warning Proposed Repair Actions:

No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 29 PERIPH_LOAD_TSK Error description: The loading of a MSCI/TRAC card has been aborted because of an unrecoverable file transfer protocol error. Th loading abort of MSCI active card causes the switch of the BSMS configuration or the reset of the BSMS active, if the standby is not available. The loading abort of MSCI standby card causes the reset of the BSMS standby. The loading abort of a TRAC card reinitializes the procedure; if the maximum attempts number is reached, the card is disabled.

0102 (D)= code statement number

0304 (D)= error type or parameter value

0506 (D)= link (card) identifier:

00-05 TRAC 0-5

06 MSCI

0708 (D)= processor identifier (meaningful for TRAC cards):

00 Trac controller

01 Dsp

0910 (D)= last transmitted packet

1112 (D)= FSM state value

1314 (D)= source system of received message

1516 (D)= signal type of received message

1718 (D)= signal subtype of received message

1920 (D)= transmitted bytes

2122 (D)= not used

2324 (D)= not used

2526 (D)= not used

2728 (D)= not used

2930 (D)= not used ##1110-##2

Page 163: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 163

##1111-##1

4.8 Software Program Abnormally Terminated

4.8.1 1111 - DELETED_CURRENT_TASK FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Software Program Abnormally Terminated Specific Problems: DELETED_CURRENT_TASK Severity: Warning Proposed Repair Actions:

No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 123 RTE_ORIGINATOR Error description: The RTE+ operating system has deleted the current task or aborted the current scan work function.

0102 (D)= Task logical name

0304 (D)= not used

0506 (D)= If greater than 0, interrupt which caused the task to be deleted together with the processor

register values

0708 (D)= segment of the task executing during the interrupt

0910 (D)= offset of the task executing during the interrupt

1112 (D)= CS register value

1314 (D)= IP register value

1516 (D)= SS register value

1718 (D)= SP register value

1920 (D)= BP register value

2122 (D)= DS register value

2324 (D)= ES register value

2526 (D)= SI register value

2728 (D)= AX register value

2930 (D)= BX register value ##1111-##2

Page 164: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

164 A30808-X3247-M440-1-7619

##1112-##1

4.8.2 1112 - DELETED_CURRENT_INIT_FUNCTION FAILURE EVENT REPORT:

Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Software Program Abnormally Terminated Specific Problems: DELETED_CURRENT_INIT_FUNCTION Severity: Warning Proposed Repair Actions:

No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words:

0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930

Originator: 123 RTE_ORIGINATOR Error description: The RTE+ operating system has deleted the current task or aborted the current scan work function

0102 (D)= Last initialization index

0304 (D)= Initialization function index

0506 (D)= If greater than 0, interrupt which caused the task to be deleted together with the processor

register values

0708 (D)= segment of the task executing during the interrupt

0910 (D)= offset of the task executing during the interrupt

1112 (D)= CS register value

1314 (D)= IP register value

1516 (D)= SS register value

1718 (D)= SP register value

1920 (D)= BP register value

2122 (D)= DS register value

2324 (D)= ES register value

2526 (D)= SI register value

2728 (D)= AX register value

2930 (D)= BX register value ##1112-##2

Page 165: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 165

5 Index of Specific Problems 11 - LOSS_OF_SIGNAL.................................................................................................................................. 46 12 - AIS_ALARM ............................................................................................................................................. 48 13 - LOSS_OF_FRAME_ALIGNMENT ......................................................................................................... 131 14 - LOSS_OF_CRC_ALIGNMENT.............................................................................................................. 133 15 - REMOTE_ALARM.................................................................................................................................... 99 16 - HIGHER_BER_THRESHOLD_EXCEEDED.......................................................................................... 105 17 - LOWER_BER_THRESHOLD_EXCEEDED .......................................................................................... 107 18 - LOSS_OF_SIGNAL_ON_LINK_A............................................................................................................ 50 19 - LOSS_OF_SIGNAL_ON_LINK_B............................................................................................................ 52 20 - AIS_ALARM_ON_LINK_A ....................................................................................................................... 54 21 - AIS_ALARM_ON_LINK_B ....................................................................................................................... 56 22 - LOSS_OF_FRAME_ALIGNMENT_ON_LINK_A ................................................................................... 135 23 - LOSS_OF_FRAME_ALIGNMENT_ON_LINK_B ................................................................................... 136 24 - LOSS_OF_CRC_ALIGNMENT_ON_LINK_A........................................................................................ 137 25 - LOSS_OF_CRC_ALIGNMENT_ON_LINK_B........................................................................................ 138 26 - REMOTE_ALARM_ON_LINK_A............................................................................................................ 101 27 - REMOTE_ALARM_ON_LINK_B............................................................................................................ 103 28 - HIGHER_BER_THRESHOLD_EXCEEDED_ON_LINK_A.................................................................... 109 29 - HIGHER_BER_THRESHOLD_EXCEEDED_ON_LINK_B.................................................................... 111 30 - LOWER_BER_THRESHOLD_EXCEEDED_ON_LINK_A .................................................................... 113 31 - LOWER_BER_THRESHOLD_EXCEEDED_ON_LINK_B .................................................................... 115 1003 - TRAC_WDT_TIMEOUT ....................................................................................................................... 92 1004 - BSCI_WDT_TIMEOUT......................................................................................................................... 93 1005 - BSCI_WDT_WARNING ....................................................................................................................... 94 1006 - PLL_FAILURE...................................................................................................................................... 15 1007 - BSCI_HW_FAULT................................................................................................................................ 16 1009 - TRAC_TIMING_LOSS ......................................................................................................................... 20 1010 - HW_NOT_COMPATIBLE_WITH_INTERNAL_POWER ................................................................... 117 1012 - PROTECTED_MEMORY_ILLEGAL_WRITE_ATTEMPT.................................................................... 21 1014 - UNEXPECTED_MESSAGE................................................................................................................. 65 1015 - INPUT_PARAMETER_OUT_OF_RANGE_WARNING....................................................................... 63 1016 - AR_PROCEDURAL_ERROR ............................................................................................................ 144 1017 - RTE_INTERRUPT_LOOP ................................................................................................................. 145 1018 - STANDBY_ALIGNMENT_FAILED..................................................................................................... 146 1019 - INVALID_DATABASE_WARNING....................................................................................................... 59 1020 - PCMS_CIRCUIT_ALARM.................................................................................................................... 22 1021 - PCMA_CIRCUIT_ALARM.................................................................................................................... 24 1023 - TRAC_DBA_REFUSED....................................................................................................................... 60 1024 - SYSTEM_CALL_UNSUCCESSFUL_WARNING ................................................................................ 72 1028 - FUNCTION_CALL_UNSUCCESSFUL ................................................................................................ 74 1029 - VARIABLE_OUT_OF_RANGE ............................................................................................................ 91 1032 - TRAC_HW_NOT_COMPATIBLE_WITH_ACTUAL_CONFIGURATION .......................................... 118 1033 - MESSAGE_OUT_OF_SEQUENCE_WARNING................................................................................. 70 1034 - SCHEDULER_BLOCKED.................................................................................................................. 147 1035 - INITIALIZATION_UPDATED.............................................................................................................. 148 1036 - BSCI_HW_VERSION_NOT_VALID_FOR_PCM_TYPE ................................................................... 119 1037 - TIMEOUT_EXPIRED_WARNING........................................................................................................ 81 1038 - MSCI_HW_VERSION_NOT_VALID_FOR_PCM_TYPE................................................................... 120 1040 - MEMORY_NOT_AVAILABLE ............................................................................................................ 139 1041 - MAILBOX_CANNOT_BE_CREATED................................................................................................ 140 1042 - BSMS_DIAGNOSTIC_FAILURE ......................................................................................................... 26

Page 166: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

166 A30808-X3247-M440-1-7619

1043 - INITIALIZATION_FAILURE................................................................................................................ 149 1044 - INVALID_MESSAGE_DATA................................................................................................................ 66 1045 - TRAC_DIAGNOSTIC_FAILURE.......................................................................................................... 27 1046 - FILE_SYSTEM_ERROR.................................................................................................................... 151 1047 - TRAC_DIAGNOSTIC_ONLINE_FAILURE .......................................................................................... 28 1048 - INVALID_RTE_HEADER_FIELD_VALUE........................................................................................... 67 1049 - INTERNAL_LINK_FAILURE .............................................................................................................. 154 1052 - TPWR_DIAGNOSTIC_FAILURE......................................................................................................... 30 1053 - BSMS_PROCEDURAL_ERROR....................................................................................................... 155 1059 - MSCI_HW_FAULT............................................................................................................................... 31 1060 - MSCI_SW_ERROR.............................................................................................................................. 68 1066 - MESSAGE_NOT_SENT ...................................................................................................................... 77 1067 - INVALID_DB_CALL ............................................................................................................................. 79 1068 - TIMER_CANNOT_BE_SET ............................................................................................................... 156 1074 - TPWR_FAULT ..................................................................................................................................... 32 1075 - TRAC_KEEP_ALIVE_ALARM ............................................................................................................. 85 1077 - TRAC_HW_FAULT .............................................................................................................................. 33 1078 - MSCI_SYNC_8KHZ_FAILED .............................................................................................................. 34 1079 - MSCI_DIGA_FAULTED ....................................................................................................................... 35 1080 - TRAC_UNEXPECTED_MESSAGE..................................................................................................... 69 1081 - TRAC_FAIL_TO_LOAD ....................................................................................................................... 36 1082 - FLASH_EPROM_NOT_VALID ............................................................................................................ 37 1083 - FLASH_EPROM_MUST_BE_FORMATTED..................................................................................... 125 1084 - STANDBY_NOT_ALIGNED............................................................................................................... 158 1086 - TRAC_LINK_FAILURE ........................................................................................................................ 39 1087 - DSP_TSYNC_EXPIRED...................................................................................................................... 86 1088 - TRAC_CARD_FAILURE ...................................................................................................................... 40 1089 - DSP_FAIL_TO_LOAD.......................................................................................................................... 41 1090 - DSP_KEEP_ALIVE_ALARM................................................................................................................ 87 1091 - DATABASE_INCONSISTENCY_BRINGUP........................................................................................ 61 1093 - EMPTY_RTE_POOL_RESTART....................................................................................................... 141 1094 - EMPTY_MESSAGE_POOL ............................................................................................................... 142 1096 - SYSTEM_CALL_UNSUCCESSFUL_MINOR...................................................................................... 80 1097 - BAD_PLL_INPUT_SYNCHRONISATION ........................................................................................... 58 1098 - T_INTERFACE_MESSAGE_LOST ................................................................................................... 124 1099 - RTE_AUDIT_ERROR ........................................................................................................................ 159 1100 - BSCI_CARD_FAILURE........................................................................................................................ 42 1102 - PROBABLE_DATABASE_INCONSISTENCY..................................................................................... 62 1103 - TPWR_OFFREQUEST_PENDING.................................................................................................... 121 1104 - BSCI_KEEP_ALIVE_ALARM............................................................................................................... 43 1105 - MSCI_KEEP_ALIVE_ALARM .............................................................................................................. 44 1106 - INCONSISTENT_STATUS .................................................................................................................. 45 1107 - BSCI_RESET_CAUSE....................................................................................................................... 160 1108 - FORMATTING_FLASH_EPROM....................................................................................................... 127 1109 - INVALID_FILE_FORMAT................................................................................................................... 128 1110 - PERIPHERAL_LOADING_ERROR ................................................................................................... 162 1111 - DELETED_CURRENT_TASK............................................................................................................ 163 1112 - DELETED_CURRENT_INIT_FUNCTION ......................................................................................... 164 1113 - MEMORY_OVERFLOW..................................................................................................................... 143 1114 - INVALID_POINTER_WARNING.......................................................................................................... 64 1115 - UNABLE_TO_RUN_TEST................................................................................................................... 96 1116 - TRAC_HW_NOT_COMPATIBLE_WITH_VQE.................................................................................. 122 2001 - ASUB_TRANSIENT_FAILURE............................................................................................................ 97 2002 - UNEXPECTED_TEI ........................................................................................................................... 123 2003 - LPDL_LINK_DOWN............................................................................................................................. 98 5001 - OPEN_DOOR_ALARM...................................................................................................................... 130 5002 - FAN_ALARM........................................................................................................................................ 95

Page 167: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 167

Page 168: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

168 A30808-X3247-M440-1-7619

Page 169: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 169

6 ANNEX A TRAU SPECIFIC PROBLEM

Specific Problems

Probable Cause

Name Value Name Item Loss Of Signal 0011 LineInterfaceFailure GSM 16AIS Alarm 0012 LineInterfaceFailure GSM 16Loss Of Frame Alignment 0013 LossOfFrame ISO

28

Loss Of CRC Alignment 0014 LossOfFrame ISO

28

Remote Alarm 0015 RemoteAlarmIndication GSM 71Higher BER Threshold Exceeded 0016 TransmissionError ° GSM 74Lower BER Threshold Exceeded 0017 TransmissionError ° GSM 74Loss Of Signal On Link A 0018 LineInterfaceFailure GSM 16Loss Of Signal On Link B 0019 LineInterfaceFailure GSM 16AIS Alarm On Link A 0020 LineInterfaceFailure GSM 16AIS Alarm On Link B 0021 LineInterfaceFailure GSM 16Loss Of Frame Alignment On Link A 0022 LossOfFrame ISO

28

Loss Of Frame Alignment On Link B 0023 LossOfFrame ISO

28

Loss Of CRC Alignment On Link A 0024 LossOfFrame ISO

28

Loss Of CRC Alignment On Link B 0025 LossOfFrame ISO

28

Remote Alarm On Link A 0026 RemoteAlarmIndication GSM 71Remote Alarm On Link B 0027 RemoteAlarmIndication GSM 71Higher BER Threshold Exceeded On Link A

0028 TransmissionError GSM 74

Higher BER Threshold Exceeded On Link B

0029 TransmissionError GSM 74

Lower BER Threshold Exceeded On Link A

0030 TransmissionError GSM 74

Lower BER Threshold Exceeded On Link B

0031 TransmissionError GSM 74

TRAC WDT Timeout 1003 WatchDogTimerExpired GSM 48BSCI WDT Timeout 1004 WatchDogTimerExpired GSM 48BSCI WDT Warning 1005 WatchDogTimerExpired GSM 48PLL Failure 1006 EquipmentFailure GSM 09BSCI HW Fault 1007 EquipmentFailure GSM 09TRAC Timing Loss 1009 EquipmentFailure GSM 09HW Not Compatible With Internal Power 1010 ConfigurationOrCustomizationError ISO

07

Protected Memory Illegal Write Attempt 1012 EquipmentFailure GSM 09

Page 170: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

170 A30808-X3247-M440-1-7619

Unexpected Message 1014 MessageNotExpected GSM 42Input Parameter Out Of Range Warning 1015 InputParameterOutOfRange GSM 39AR Procedural Error 1016 SoftwareError ° ISO

46

RTE Interrupt Loop 1017 SoftwareError ° ISO

46

Standby Alignment Failed 1018 SoftwareError ° ISO

46

Invalid Database Warning 1019 DatabaseInconsistency GSM 37PCMS Circuit Alarm 1020 EquipmentFailure GSM 09PCMA Circuit Alarm 1021 EquipmentFailure GSM 09TRAC DBA Refused 1023 DatabaseInconsistency GSM 37System Call Unsuccessful Warning 1024 SystemCallUnsuccessful GSM 45Function Call Unsuccessful 1028 SystemCallUnsuccessful GSM 45Variable Out Of Range 1029 VariableOutOfRange GSM 47TRAC HW Not Compatible With Actual Conf.

1032 ConfigurationOrCustomizationError ISO

07

Message Out Of Sequence Warning 1033 MessageOutOfSequence GSM 44Scheduler Blocked 1034 SoftwareError ° ISO

46

Initialization Updated 1035 SoftwareError ° ISO

46

BSCI HW Version Not Valid For PCM Type

1036 ConfigurationOrCustomizationError ISO

07

Timeout Expired Warning 1037 TimeoutExpired ° GSM 46MSCI HW Version Not Valid For PCM Type

1038 ConfigurationOrCustomizationError ISO

07

Memory Not Available 1040 OutOfMemory ISO

32

Mailbox Cannot Be Created 1041 OutOfMemory ISO

32

BSMS Diagnostic Failure 1042 EquipmentFailure GSM 09Initialization Failure 1043 SoftwareError ° ISO

46

Invalid Message Data 1044 MessageNotExpected GSM 42TRAC Diagnostic Failure 1045 EquipmentFailure GSM 09File System Error 1046 SoftwareError ° ISO

46

TRAC Diagnostic Online Failure 1047 EquipmentFailure GSM 09Invalid RTE Header Field Value 1048 MessageNotExpected GSM 42Internal Link Failure 1049 SoftwareError ° ISO

46

TPWR Diagnostic Failure 1052 EquipmentFailure GSM 09BSMS Procedural Error 1053 SoftwareError ° ISO

46

MSCI HW Fault 1059 EquipmentFailure GSM 09MSCI SW Error 1060 MessageNotExpected GSM 42Message Not Sent 1066 SystemCallUnsuccessful GSM 45Invalid DB Call 1067 SystemCallUnsuccessful GSM 45Timer Cannot Be Set 1068 SoftwareError ISO

46

TPWR Fault 1074 EquipmentFailure GSM 09

Page 171: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 171

TRAC Keep Alive Alarm 1075 TimeoutExpired GSM 46TRAC HW Fault 1077 EquipmentFailure GSM 09MSCI SYNC 8KHz Failed 1078 EquipmentFailure GSM 09MSCI DIGA Faulted 1079 EquipmentFailure GSM 09TRAC Unexpected Message 1080 MessageNotExpected GSM 42TRAC Fail To Load 1081 EquipmentFailure GSM 09Flash EPROM Not Valid 1082 EquipmentFailure GSM 09Flash EPROM Must Be Formatted 1083 CorruptData ISO

09

StandBy Not Aligned 1084 SoftwareError ISO

46

TRAC Link Failure 1086 EquipmentFailure GSM 09DSP TSYNC Expired 1087 TimeoutExpired GSM 46TRAC Card Failure 1088 EquipmentFailure GSM 09DSP Fail To Load 1089 EquipmentFailure GSM 09DSP Keep Alive Alarm 1090 TimeoutExpired GSM 46Database Inconsistency BringUp 1091 DatabaseInconsistency GSM 37Empty RTE Pool Restart 1093 OutOfMemory ISO

32

Empty Message Pool 1094 OutOfMemory ISO

32

System Call Unsuccessful Minor 1096 SystemCallUnsuccessful GSM 45Bad PLL Input Synchronisation 1097 LossOfSynchronization GSM 18T Interface Message Lost 1098 Congestion ISO

08

RTE Audit Error 1099 SoftwareError ° ISO

46

BSCI Card Failure 1100 EquipmentFailure GSM 09Probable Database Inconsistency 1102 DatabaseInconsistency GSM 37TPWR Offrequest Pending 1103 ConfigurationOrCustomizationError ISO

07

BSCI Keep Alive Alarm 1104 EquipmentFailure GSM 09MSCI Keep Alive Alarm 1105 EquipmentFailure GSM 09Inconsistent Status 1106 EquipmentFailure GSM 09BSCI Reset Cause 1107 SoftwareError ° ISO

46

Formatting Flash EPROM 1108 CorruptData ISO

09

Invalid File Format 1109 CorruptData ISO

09

Peripheral Loading Error 1110 SoftwareError ° ISO

46

Deleted Current Task 1111 SoftwareProgramAbnormallyTerminated

ISO

47

Deleted Current Init Function 1112 SoftwareProgramAbnormallyTerminated

ISO

47

Memory Overflow 1113 OutOfMemory ISO

32

Invalid Pointer Warning 1114 InvalidPointer GSM 41Unable To Run Test 1115 SystemResourcesOverload GSM 64Asub Transient Failure 2001 LAPDLinkProtocolFailure GSM 69

Page 172: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

172 A30808-X3247-M440-1-7619

Unexpected TEI 2002 ConfigurationOrCustomizationError ISO

07

LPDL Link Down 2003 LAPDLinkProtocolFailure GSM 69Open Door Alarm 5001 EnclosureDoorOpen ISO

14

Fan Alarm 5002 Fan Failure GSM 53

Page 173: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 173

7 ANNEX B TRAU FER PROPOSED REPAIR ACTION

1 NoAction (Standard value). 2 RepairActionRequired (Standard value - not used). 3 Replace the addressed card. 4 Test the addressed card(s) and perform the proper action according to the Test Result. Possibly,

check also its (their) insertion in the frame. 5 Alarm with warning severity. Refer to the manual for the proposed action. 6 Environmental alarm. The repair action is defined by the operating company. 7 Wait for the end of the Automatic Diagnostic and then perform the proper action according to the

Test Result. 8 Check on both sides the parameters of the line connecting the BSC and the faced Network Entity.

Then, if it is all right, replace the line interface cards with the correct FW/HW edition. 9 Check on both sides the parameters of the line connecting the BSC and the faced Network Entity.

Then, check the line interface card state including the FW/HW editions. If it is all right, test the line interface cards. Finally, check the PCM cables and the HW of the faced Network Element.

10 Check the PCM cable connected to the LICD and, possibly, tune the related BER. 11 Check the signal emitted by the faced Network Element. Then, check the devices on the path

between the BSC and the Network Element (CrossConnect, ..). 12 Correct the configuration attribute value(s) for the addressed card(s) or replace the Hardware with

one compatible with the configuration. 13 Insert the addressed card in the frame. Then, test it. 14 If the addressed card is the StandBy one, test it. 15 Check the related cables, connections and line quality. 16 Lock the related equipment. 17 Provide information on the state of the BSC card versions (LICD, PLLH, SN) and speech quality to

the customer service. 18 Wait for the PLLH warm up (about 15 minutes). 19 Check on both sides the LAPD parameters (TEI, LAPD timeslot) and correct them, if necessary. 20 Format the Flash EPROM of the concerned BSCI card. 21 If there are no more SYNC (SYNE) Managed Objects available to be automatically chosen as a new

synchronization source, create a new one. 22 Check the insertion of the LICD in the frame, then test it. If the Test Report is good, replace the

UBEX. 23 Replace the LICD and, if after re-entering in service, the problem is already present, call the

customer assistance (problem of PLLH, active SN, Rack or Flat cable connecting base and extended modules).

24 If the BSC is synchronized to the MSC, it is a problem of bad external source. If the BSC is free running, it is a problem of bad PLLH signal. Then, tune the PLLH.

25 Test the related MPCC and perform the proper action according to the Test Result. 26 Check the TRAU Network Entity. 27 Check the BTS HW. 28 Check the barring information and the BTS HW. 29 Check the TRX HW.

Page 174: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

174 A30808-X3247-M440-1-7619

List of strings to be displayed on the OMC/LMT

1 No Action 2 Repair action required 3 Replace the addressed card 4 Test the addressed card(s) 5 See the proposed action in the manual. 6 See the foreseen operating company repair action 7 See the automatic diagnostic test result 8 Check line configuration on both side 9 Check line configuration/HW on both side 10 Check the LICD PCM cable, tune the BER 11 Check the received signal 12 Check the configuration/HW compatibility 13 Insert and test the addressed card 14 Test the card if it is a standby one 15 Check cables, connections, line quality 16 Lock the related equipment 17 Collect info for Assistance (see manual) 18 Wait for the PLLH warm up (15 minutes) 19 Check the LAPD parameters on both side 20 Format the BSCI Flash EPROM 21 Create a new SYNC (SYNE). 22 Test the LICD. If ok, replace the UBEX 23 NWK,LICD,Flat Cable problem (see manual) 24 Change sync source or tune the PLLH 25 Test the related MPCC 26 Check the TRAU 27 Check the BTS HW. 28 Check barring information and BTS HW 29 Check the TRX HW.

Page 175: trauoml

Transcoding and Rate Adaption Unit Outputs OML:TRAU

A30808-X3247-M440-1-7619 175

8 ANNEX C TRAU ORIGINATOR

DEFINE

VALUE

Power Supply Device Controller 16 IPC_LAYER2_TSK 17 IPC_COLLECTOR_TSK 18 IPC Dispatcher 19 IPC Link Maneger 20 LMT_IO_DLM_TSK 21 LMT_IO_COLL_TSK 22 Data Base 23 SM_COMM_TSK 24 Alarm Reporting 25 BSMS Device Handler 26 TRAC Device Handler 27 DOWNLOAD_TSK 28 PERIPH_LOAD_TSK 29 BIFRAMETX_TSK 30 BUFRAMETX_TSK 31 BSC_LINKMNGR_TSK 32 LMT_LINKCTRL_TSK 33 RAM CRC 34 Alignment Service Task 35 FAFS_COMPACTION_TASK 36 SPARE_3_TSK 37 Status Manager Notify Handler 38 PCM Device Controller Task 39 CROSSCOPY_TSK 40 Sync Device Handler 41 BDGDMPEPR_TSK 42 BDGDMPIPR_TSK 43 STBY_DIAG_TSK 44 BSMS_STBY_DIAG_AGENT_TSK 45 EVENT_LOG_TSK 46 DC ENVA TSK 47 RI Task 48 Error Collector 100 NMI Interrupt Handler 101 Spontaneous Alarm 102 ALARM_TILT_ORIGINATOR 103 ALL1_PLL_ORIGINATOR 104 MIR_PLL_ORIGINATOR 105 OTH_CARD_WDT_ORIGINATOR 106 ALL2_PLL Interrupt Handler 107 PROTECT_MEM_ORIGINATOR 108 ALM_SPON_ORIGINATOR 109

Page 176: trauoml

Outputs Transcoding and Rate Adaption Unit OML:TRAU

176 A30808-X3247-M440-1-7619

SM_COMM_ORIGINAT 110 BSMS Fault Detection 111 INT_TILT_ORIGINATOR 112 TEST_BSMS_ORIGINATOR 113 TRAC fault detection 114 FAULT_DETECTION_TPWR 115 WDT Fault Detection 116 FOMDH_FLASH_CHECK_TSK 117 FOMDH_RAM_CHECK_TSK 118 TPWR_TEST_TSK 119 Test BSMS 120 HSCX Init Handler 121 BSCI Audit 122 RTE_ORIGINATOR 123 BLOADER_ORIGINATOR 124 NACK_ACK_ANSWER 129 FDGDM_DIAG_ACTIVATION0 130 FDGDM_DIAG_ACTIVATION1 131 SEND_TEST_IN_PROGRESS 132 SEND_PHASE_RESULT 133 TDGDM_PI_PROCESS 134 TDGDMPI_STBY 135 FDGDM_IRAS 136 Activate Test 137 FDGDM_SYNC_DEVICE0 138 FDGDM_SYNC_DEVICE1 139 STOP_TEST_RUNNING 140 SEND_DSC_TO_SM 141 UPDATE_BSCI_STBY 142 SEND_OUTPUT_RESULT 143 SEND_DUMMY_RESULT 144 FDGDM_OUTPUT 145 FDGHD_BSMS 146 FDGHD_TRAC 147 FDGHD_TPWR 148 MSCI_DIAG_CONTROLLER 149 TDGHD_BSMS_STBY 150 BSCI FW 151