TERI Water Bath Heaters for the Energy Industry

26
Now available from Linc Energy Systems.

Transcript of TERI Water Bath Heaters for the Energy Industry

Now available from Linc Energy Systems.

Visit us at www.LincEnergySystems.com

Indirect fired water bath heaters for the utility, processing, and upstream oil & gas industry.

Water bath heaters are commonly used in applications where bath process temperature does not exceed 170°F.

Overview

Hundreds of successful installations

Visit us at www.LincEnergySystems.com

Applications

Heating natural gas prior to pressure reduction to eliminate hydrate formation downstream of expansion valving.

Heating well stream fluids prior to phase separation.

Heating process streams to maintain fluid viscosity at a minimum to reduce HP pumping requirements.

Heating critical feed stocks that require tightly controlled film to bulk temperature differentials.

Heating turbine fuel gases to maintain a given dew point temperature.

Heating natural gas for upstream pressure regulation stations to prevent condensation due to Joule – Thompson effect.

Visit us at www.LincEnergySystems.com

Types of Heaters

Natural Draft: Burner relies on a stack to create negative pressure at the burner inlet.

Forced Draft: Heaters utilize small bore fire tubes plus a combustion air fan. High velocities reduce the “dead gas film” region, allowing reduced tube area compared to large bore tubes.

Vertical: Less industrial appearance, smaller footprint and totally enclosed to reduce burner noise and protect controls from environment.

Horizontal: Most commonly seen today.

Horizontal Forced Draft HeaterHorizontal Natural Draft Heater Vertical Heater

Visit us at www.LincEnergySystems.com

Heater Components

Heater Shell: Atmospheric vessel designed in accordance with API-12K requirements containing the process coil, fire tube (combustion chamber) and heat media.

Process Coil: Pressure-containing part commonly designed in accordance with API-12K or ASME Section VIII Division 1 code.

Flue Gas Stack: Provides positive flue gas flow (draft) constructed of stainless steel with a clean-out tee at the bottom and a secure bird cage cover bolted to the top.

Fire Tube: Commonly U-tube configuration. Removable tube designed to efficiently transfer heat into surrounding heat media and minimize flue gas friction losses.

Flame Arrestor: Prevents transmission of flame within combustion chamber when exposed to external fuel source. Reduces temperature of fuel to withstand the internal forces of explosion.

Visit us at www.LincEnergySystems.com

Heater Components (cont.)

Expansion Tank: Reduces corrosion in the heater shell by keeping it liquid-packed and moving the wet-dry interface of the expanding bath media into the expansion tank.

Gas Train: Built to API-12K, with larger heaters using NFPA 87 as guideline.

Burner: The Eclipse Burner is a TERI standard, and uses an eductor to draw in combustion air and push combustion gasses through fire tube.

Pilot in a Drawer: Eliminates nuisance pilot outages with a dedicated combustion air pilot assembly. Allows all air required for proper combustion of the pilot gases to be pulled directly from outside of the main flame arrestor. Allows easy access to the pilot components for maintenance and inspection, and eliminates pilot outages due to a rich combustion chamber environment.

Header: Where cold processed gas enters the heater coil and heated processed gas exits the heater coil.

Visit us at www.LincEnergySystems.com

Heater Shell

Atmospheric vessel designed in accordance with API-12K requirements

containing the process coil, fire tube (combustion chamber) and heat media.

Visit us at www.LincEnergySystems.com

Process Coil

Pressure-containing part commonly designed in accordance with API-12K or ASME Section VIII Division 1 code.

Visit us at www.LincEnergySystems.com

Flue Gas Stack

Provides positive flue gas flow (draft) constructed of stainless steel with a clean-out tee at the bottom and a secure bird cage cover bolted to the top.

Visit us at www.LincEnergySystems.com

Fire Tube

Commonly U-tube configuration. Removable tube designed to efficiently transfer heat into surrounding heat media and minimize flue gas friction losses.

Visit us at www.LincEnergySystems.com

Flame Arrestor

Prevents transmission of flame within combustion chamber when exposed to external fuel source. Reduces temperature of fuel to withstand the internal forces of explosion.

Visit us at www.LincEnergySystems.com

Expansion Tank

Reduces corrosion in the heater shell by keeping it liquid-packed and moving the wet-dry interface of the expanding bath media into the expansion tank.

Visit us at www.LincEnergySystems.com

Gas Train

Built to API-12K, with larger heaters using NFPA 87 as guideline.

Visit us at www.LincEnergySystems.com

Burner

The Eclipse Burner is a TERI standard, and uses an eductor to draw in combustion air and

push combustion gasses through fire tube.

Visit us at www.LincEnergySystems.com

Pilot in a Drawer

TERI’s Pilot in a Drawermounting box

Special dedicatedpilot air fuel to airmixer assembly

Pilot flamearrestor housing

Visit us at www.LincEnergySystems.com

Pilot in a Drawer

Pilot arrestorconnection

Pilot gas filterregulator

Johnson Controls “Baso” pilot guardand thermocouple assembly

Visit us at www.LincEnergySystems.com

Complete TERI Pilot in a Drawer Assembly

Visit us at www.LincEnergySystems.com

Header

Where cold processed gas enters the heater coil and heated processed gas

exits the heater coil.

Visit us at www.LincEnergySystems.com

Engineered Solutions

Plasma-cut shop fabricated components

Individually removable fire tubes

304 SS Flue gas stacks

Stack clean out tee

Flue gas stack anti reverse-draft diverters with rain cap and bird screens

“Pilot in a Drawer” assemblies for easy maintenance and inspections

Basic electric & pneumatic in addition to PLC control systems

Multi-mitered fire tube bends (no single miter cut to greater than 22.5 degrees)

Positive seal flange design

Standard Features Include:

Visit us at www.LincEnergySystems.com

Engineered Solutions

Bath liquid expansion reservoir designed to hold 7% of the total bath media

Bath liquid level gauge and temp indicator

Shell designed to API-12K

Coil designed and stamped ASME-8-1

100% radiography on process coil welds

Process coil, national board stamped in accordance with ASME – 8-1

Basic electric and pneumatic controls

Sophisticated PLC control systems that allow for heater remote monitoring and operation

Standard Features Include (cont):

Visit us at www.LincEnergySystems.com

Engineered Solutions

Pneumatic-controlled equipment operation

Electrical-controlled equipment operation

Combination pneumatic- and electrical-controlled equipment operation

Flame safeguard assemblies including pneumatic 120VAC and 12VDC or solar power

Manual or automatic pilot ignition designs

Optional Control-Enhanced Designs

Visit us at www.LincEnergySystems.com

TERI Indirect Fired Natural Draft Water Bath Heaters feature custom designedand manufactured and removable expansion tanks.

Visit us at www.LincEnergySystems.com

TERI Forced Draft Triple Burner Heater being loaded for transport.

Visit us at www.LincEnergySystems.com

Forced Draft Dual Burner Heater

Visit us at www.LincEnergySystems.com

These custom engineered and manufactured TERI brand Glycol Dehydration Skids,each capable of up to 20 GPM TEG, were designed to replace older equipmentat this midwest installation – without reconfiguring existing structures or piping.

Visit us at www.LincEnergySystems.com

Contact your TERI Representative

Address: 11919 W. I-70 Frontage Rd. North Unit #109Wheat Ridge, Colorado 80033

Phone: 303-697-6701

Fax: 303-697-6744

Email: [email protected]