scada1

download scada1

of 14

description

SCADA System

Transcript of scada1

Bentek SystemsSCADA & Telemetry Solutions

HomeProductsServicesApplicationsTechnotesSupportContact UsWireless SCADA / RTUThe term SCADA (Supevisory Control And Data Acquistion)

typically refers to systems where a central computer master

or PLC masters communicates to multiple remote RTUs

(Remote Terminal Units) or PLC's using RTU or PLC data

communication protocols including protocols such as Modbus,

AB-DF1, and DNP3.0. The SCADA host will perform

centralized alarm management, data trending, and operator

display and control. With a SCADA system architecture, the

host communicates to the remote sites via protocol data

communications. A SCADA architecture can easily be

expanded to handle additional remote sites and i/o points.

SCADA communications can use a range of wired

(lease line, dialup line, fiber, ADSL, cable) and wireless

media (licensed radio, spread spectrum, cellular, CDPD,

satellite) depending which is available and the most cost

effective. Frequently for remote applications, wireless

SCADA is the only feasible alternative due to availability

and cost.

Wireless SCADA systems can range from simple

Point-Multipoint systems like the 900-MB Spread Spectrum

system below using Modbus protocol:

Radio RTU

Wireless Radio based remote terminal unit basically allows transfer status, control and measurement of signals from remote site to central control room. Latest Radio based systems of today allow convenient and more reliable wireless controls far beyond the boundaries of rooms and buildings without the need of expensive cabling and site preparation work . Specially designed for harsh industrial conditions. RTU supports Digital and Analog Communications.

Types of Radio RTU

RTU 700 H FTR 700 HP8

Radio RTU Radio Modem Ethernet Hub Ethernet Modems GSM Modems GSM RTU RRC for Cranes

Radio Modem

Stand-alone radio modems are designed to provide end users with an easy - to - install wireless serial communication link.

These Radio modems come equipped with the features of our wireless OEM modules. Systems integrator will enjoy the functionality provided by the serial connection, power switch, indicator lights, high quality antenna, mounting plates and power source inputs.

380-470 Mhz (Upto 10 W RF O/p with 19200 Bps over air with RS 232 and 485 Interface)433-434 MHz (Upto 1 W RF O/p with 2400 BPS over air with RS 232/485 Interface)2.4 GHz (The 2.4GHz radio modem with 1 W RF o/p with 1 Mbps over Air with Ethernet InterfaceEthernet Hub:

The SpectraNT 2400 is powered by the MHX-2400 radio core, but provides an RJ-45 10BaseT Ethernet interface. This product is ideal forindustrial wireless Ethernet applications. SpectraNT 2400

Ethernet Modem

The Spectra 2400 is the enclosed version of the MHX-2400 specifically designed for high-performance frequency hopping spread spectrum industrial applications. The rugged extruded aluminum enclosure and wide operating voltage range ensure easy integration into most any end-user application.The interface is a standard RS-232 or an optional RS-485/RS-422 interface. Spectra 2400

TopGSM Modems

The GSM is a Hayes-compatible modem that accepts modified "AT-" commands and communicates over standard GSM radio networks. Data, faxes, email, etc., can be transmitted over existing GSM radio networks using these modems. An embedded microprocessor handles all the GSM communication functions of the GSM Modem GSM - 1000

GSM RTU

Plant, equipment, systems, and processes increasingly need reliable yet economical means of remote monitoring and control. The technology and products for this have been available for several years, but the costs and technical problems have been significant. These obstacles made it difficult in the past to implement such systems. The GSM Server System developed by Funk Electronic Piciorgros GmbH now provides a convenient and cost-effective way to meet such user requirements.

GSM-2110 Remote Alarm, Control and Data Logging Unit for GSM Cellular Networks

GSM-8110 Universal Remote Control and Alarm Monitoring System RRC for Crane

RRC is a highly durable, sophisticated and safe industrial radio remote control system. The versatile features of the RRC permit their use in many different remote control applications. The system is used to control factory cranes, monorail systems, multiple hoists, trolleys, mining equipment, automatic control systems, and many others. The system incorporates numerous redundant safety circuits that guaranty maximum security and ensure that the system is resistant to outside interference.

Intelligent RTU's and Controllers

Our Intelligent RTU's and controllers give you the innovative advanced features you want combined with the reliability, ease of use and cost-effectiveness that you need. They combine the best of traditional industrial strength RTU and PLC technology with the best of the PC and Internet revolutions.

There are three product series within this class: 1) the ScadaFlex Plus RTU/controller, 2) the EtherLogic RTU/controller and 3) the ICL-4300 RTU/controller.

They share the same application development software tools and many of the same features. See our Selection Guide to help you choose the appropriate model.

To find out more about our intelligent RTU's and Controllers, choose a model from the selections below:

ScadaFlex Plus RTU/controller

EtherLogic Controllers

ICL-4300 RTU/controller

All the advanced technology and features in the world don't get you anywhere, unless you can successfully configure or program the unit for your application. We have put many man-years of effort into developing the tools to make this as easy as possible for you. Many of our first-time customers have commented on how quickly they were able to get our Intelligent RTU's and controllers up and running for their application.

To help you quickly and effectively complete your task, we feature:

Accurate, concise and well-written technical manuals written by the team of engineers who created the products.

Excellent and very accessible technical support provided by competent engineers with years of experience in the industry, just a toll-free (USA) telephone call away. When you call ICL, a person answers the phone and you can normally reach a Technical Support Engineer immediately.

Several application development environments are available, so you can choose the one that best meets your needs.

We provide many sample applications as part of each application development environment. These samples can be copied and modified for your own use.

Extensive function libraries help minimize your work.

We are constantly improving our tools to help you to become more effective and efficient.

Get the details on:

Application development environments & SDKs

Internet features

Data logging

Alarm annunciation

Communications

Textual User Interface

Selection Guide

Products | Support | What's New | Company | Contact Us | Events | Home

RADIO RTU

RTU 700H :The Radio RTU is a general-purpose wireless remote I/O module, widely used in industrial monitoring and control, water and effluent treatment plants, pipeline monitoring, and other applications where long distances or other obstacles make it difficult or uneconomical to use wire communication.

FTR 700The FTR-700 Radio Terminal Unit combines the functions of a radio modem for the ISM band and on-off input/output interface unit. It is designed in accordance with LPD and CEPT-LPD ETS 300 220. It meets all national and EC requirements relating to radio equipment and its usage, and conforms to CE specifications.

Downloads for Radio RTU Manual RTU 700H FTR 700HP8 FTR 700HD2

Products Radio RTU Radio Modem Ethernet Hub Ethernet Modems GSM Modems GSM RTU RRC for Cranes

Top

Wireless Remote I/O Modules with WideApplications Capabilities Model RTU 700 H

Radio communications links used for monitoring waste watersystems, fresh water supplies, gas and oil pipeline voltage converting stations, etc., are often required to span distances up to 100 km.The TRU 700 H sends wireless I/O Modules not only combine the functions of on-of analog I/O and wireless modem but also can act as wireless repeater stations to extend communication distances.

The Basic Module has 16 on-of inputs and 8 on-of (PNP transistor), outputs ,8 counter registers, and 8 timer registers. Another version of the BasicModule additionally has 4 analog inputs.The I/O capacity of a Basic Module can be expanded by connectionExpansion Modules via a external high speed bus Port. Expansion Modules are available with a variety of on-of and analog I/O configurations.Up to 8 Expansion Modules can be connected to single Basic Module.

Distributed I/O systems can be configured with up to 240 slave stations in a single wireless network by setting distinctive stationaddresses via DIP switches.The RTU 700 His available with a choice of RF output power ratings..

RF power output limit can be set for each station and measured values of received signal strength read for each station, by remote wireless access from a central SCADA station.This allows the system to be uickly set up without the need foradditional measuring instruments.The RTU 700 H series are readily integrated with systems using third party software (SCADA applications, OPC servers, etc..)

Features of RTU - 700H High performance 500 mW or 6 W radio module 400 500 MHz operating range 64 radio channels (DIP switch selectable) DIN-Rail mounting 16 digital inputs, 8 digital outputs and 4 analogue inputs on board 8 event counter, 8 timer Isolated inputs and outputs LED I/O and radio field strength indicator Connector for expansion units (local bus) Power supply range 12-24Volt DC

Top

ISM Band RTU : model FTR 700 HP 8

The FTR-700/P8 Radio Terminal Unit combines the functions of a radio modem for the ISM band and on-off input/output interface unit. It is designed in accordance with LPD and CEPT-LPD ETS 300 220. It meets all national and EC requirements relating to radio equipment and its usage, and conforms to CE specifications.

The P 8 series includes a Basic Module with 8 potential free on off inputs and relay outputs, which can operate in a point to point link, or in a multi-station network. They can also be readily integrated into SCADA systems. The I/O capacity of the Basic Module can be expanded by connecting one or more local expansion modules , with various on-off and analog I/O configurations. Up to 8 Expansion Modules can be connected to a single basic module.

REMOTE MONITORING AND CONTROL

SCADA OVERVIEW

Home

Products

User Profiles

Application Families

Advantage Newsletter

What's New

Corporate

Contact

Site Map

Search

Radio Dispatch Consoles

Dispatch Telephony

Trunked Radio Systems

Paging Systems

Monitoring and Control Systems

Private Radio Components

Custom Solutions

From the cold of Siberia to the heat, salt and moisture of offshore oil platforms, Zetrons SCADA (Supervisory Control and Data) systems are proven performers in a wide variety of industries and applications. Day and night, Zetron wireless SCADA systems reliably perform such vital tasks as:

Closed loop process control Equipment monitoring Malfunction detection and correction Maintenance record logging

Modern technology has allowed the evolution of SCADA to include greater data accuracy, complex analysis, automatic intelligent control, sophisticated data manipulation, and tighter security. As communities grow, as coverage areas expand, and as operations become more complex, the need to enhance existing SCADA systems or to install new systems is inevitable.

SCADA SYSTEM

SCADA Components

A SCADA system automates and centralizes the monitoring, control, and alarming of remote equipment. Zetron Remote Terminal Units (RTUs), located at multiple sites, collect data from electronic devices, and forward the data to a central control center. The Zetron Controller, as a front-end processor, manages the flow of data between the remote RTUs and the Control Program in the central host management system. The Control Program displays and analyzes data from reporting sites, issues alarms, reports on abnormal events, and initiates corrective actions as directed by an operator or automated instructions.

SCADA Benefits

The ability of a SCADA system to not only monitor the status of equipment, but to control the remote equipment from a central location, allows more efficient and cost-effective management of remote sites. Routine adjustments to levels, power, pressure, temperature, etc. improve system performance while reducing maintenance costs. Response time to emergencies is significantly reduced.

Benefits of Zetron SCADA Systems and Components

Wireless Communications

To reduce operating expenses, minimize installation costs, and maximize efficiencies, applications with widely-dispersed sites benefit significantly from wireless connections between the control center and remote sites. Zetron SCADA is compatible with conventional and most popular trunked radio systems. RTUs can also use licenseless spread spectrum or data radios for direct connection to host systems.

Cellular, Dial-up, or Lease-line Telephone Communications

Because telephone dial-up and leased-line data transfer between the Control Program and RTUs are supported, the best type of communications option can be selected for each site.

Polling, Report-on-Alarm, or Both

RTUs can report when alarm conditions are detected, when polled by the central controller, or both.

Alarm Reporting

Operators are notified of alarm conditions. Alerts and reports ensure that malfunctions and abnormalities are corrected. Logs are archived for trend analysis and regulatory compliance.

Compatible and Flexible

Wireless SCADA components can work together as a complete Zetron system or can be integrated into systems comprised of multiple vendor components.

Wide Selection

Zetron offers a range of SCADA components based on the size and complexity of the application. Each remote site can be equipped with an RTU correctly sized and configured. The control center can have the right Controller to manage communications between the Control Program and multiple RTUs.

Last modified April 1, 2001

Mission-Critical Operations

REMOTE MONITORING AND CONTROL

APPLICATION FAMILIES

Home

Products

User Profiles

APPLICATION FAMILIES

Advantage Newsletter

What's New

Corporate

Contact

Site Map

Search

Radio Dispatch Consoles

Dispatch Telephony

Trunked Radio Systems

Paging Systems

Monitoring and Control Systems

Private Radio Components

Custom Solutions

SCADA SystemsWireless SCADA integrates a central control computer with remote units to provide economical monitoring and control of remote sites using reliable cellular or radio connections. The remote system can open and close valves, take measurements, and turn switches on or off using standard devices. The user sets parameters for the control program to automatically direct the remote system to take appropriate action.Zetron's Remote Terminal Units and System Controller can communicate with and be controlled by other vendor's Control Programs, process control applications, and with programmable logic controllers (PLC) via the MODBUS communications protocol.Upgrade an existing SCADA system with Zetron's wireless RTUs and Controller.To meet the demand for SCADA systems that range from a small system that monitors several remote sites to a large systems that handles 200 remote sites, Zetron combined the flexibility of the Zetron RTUs with the power of National Instruments "Lookout" Control Program.Zetron Wireless SCADA SystemScalable to any Size OperationZetron can provide a SCADA system, comprised of Zetron RTUs, Controller and Lookout Control Program, that is ideal for any size system. The Lookout SCADA system can monitor over 150 sites with 10,000 input/output points.

Lookout is a powerful, Windows based Control Program manufactured by National Instruments, a leading supplier of computer-based measurement and automation products.

Lookout features user-designed control panels, graphic system diagrams, trend charts, activity reports, alarms screens, and programmable control logic in an easy-to-use format. Example Screens from Lookout

SCADA System Components for Multi-Vendor SystemZetron Remote Terminal Units (RTUs) can be integrated into SCADA systems comprised of multiple-vendor RTUs and a third-party Control Program. By integrating Zetrons wireless SCADA controller and remote units into an existing SCADA system, the coverage area of the SCADA system can be economically expanded. Remote sites, previously impossible or impractical to monitor and control from a central location can now be incorporated into a SCADA system with minimal investment.

Platform CompatibilityZetron Controllers and RTUs can communicate with and be controlled by National Instruments Lookout Control Program or by a wide-range of third-party Control Program software packages that support MODBUS. Control Programs, such as In-Touch by Wonderware, Fix by Intellusions, and Genesis by Iconics, are compatible with Zetron RTUs and Controllers.Zetron offers three levels of RTUs to allow each equipment site to be equipped with an RTU with the appropriate input/output capacity. All Zetron RTUs offer a full range of inputs and outputs, including digital inputs/outputs, analog inputs/outputs, pulse counters, and accumulators.

RTUs can store and forward data sent between the Controller and other RTUs, allowing communication with RTUs beyond the range of the central station.

All of Zetron RTUs support the MODBUS protocol which allows direct interface with data or spread spectrum radios.

Communication InterfacesInterfaces are available with Zetron SCADA products to provide the flexibility to communicate with different media. A radio interface is available for most popular conventional and trunked radio systems. All transmissions are error checked and acknowledged.

A Telephone Interface (Model 1732 only) uses the industry standard AT command set and works with standard dialup and cellular telephones.

The spread spectrum radio interface is an option that features a 1-Watt, 902-928 MHz transceiver. No license is required in most areas when a spread spectrum radio is used. Repeater configuration provides a wider coverage area.

The controller manages the transfer of data between remote RTUs and the control program via conventional or trunked radio systems in licensed and unlicensed spectrums.

A Zetron controller can transfer data to the Lookout control program or third-party control programs that support MODBUS protocol.

The number of RTUs a controller can handle is determined by the control program, capacity of the radio channel, and polling response time. Remote Terminal UnitsRTU CAPABILITIES MODEL M1708M1716 M1732Max No. Digital Inputs816264Max No. Digital Outputs816261Max No. Analog Inputs48196Max No. Analog Outputs-

464Max. No. Relay Outputs-

-

97

Economical Solution Model 1708 and Model 1716 Remote Terminal Unit

Models 1708 and 1716 RTUs provide high-performance monitoring at a great value for small or simple applications, such as pump control, door open/closed, temperature status, or water level measurement.Even in a complex system that requires M1732 RTUs to handle larger sites, the M1708 and M1716 can monitor sites with minimal I/O. The M1708 provides 8 digital inputs, 8 control outputs, and 4 analog inputs. The M1716 provides 16 digital inputs, 16 control outputs, 8 analog inputs, and 4 analog outputs.

Expandable Solution Model 1732Remote Terminal Unit

The Model 1732 is Zetrons most powerful RTU. It is typically used for large or complex sites. Communication between the M1732 RTUs and the Control Program can be via cellular phone, PSTN, radio, or wireline.The Model 1732 has expandable inputs and outputs with up to 16 of any one type Analog I/O, Digital I/O, and Relay Output. This modular architecture ensures that the M1732 can handle current input/output requirements with an upgrade path to a maximum of 445 I/O points. The Model 1732 includes user-programmable control logic for PLC functionality. Control logic gives M1732 RTUs ladder logic functionality for pump rotation, emergency comm fail procedures, and other operations based on local inputs and outputs. In the event of a communications failure, the M1732 can operate in a failsafe mode and execute predefined local control.

A Windows-based configuration utility simplifies RTU setup. Configurations are uploaded directly, by telephone, or over-the-air.ControllersCONTROLLER CAPABILITIES MODEL M1700M1730Max No. Input/Outputs4 Digital Outputs455 Digital and AnalogInputs/Outputs No. RTU"s SupportedUp to 250Up to 150*Controls M1708 & M1716 RTU"sYesYesControls Model 1732 RTU-Yes*Limited with MODBUS option.The Controller manages the transfer of data between remote RTUs and the Control Program via conventional or trunked radio systems in licensed and unlicensed spectrums. A Zetron Controller transfers data to the Lookout Control Program or third-part control programs that support MODBUS protocol. The number of RTUs a Controller can handle is determined by the Control Program, capacity of the radio channel, and polling response time. Controls Low-end RTUsModel 1700 Controller

The Model 1700 is an economical System Controller used in Wireless SCADA systems. The controller manages the transfer of data between Remote Terminal Units (RTUs) and the Control Program via conventional or trunked radio systems. The Model 1700 is ideal for small SCADA systems that include Zetrons Model 1708 and Model 1716 RTUs. It provides 4 digital outputs and supports up to 250 RTUs. RTU & Controller in OneModel 1730 Controller

The Model 1730 Controller manages communications for a medium to high-end SCADA system that includes any mix of Zetron RTUs, including the M1732, M1716, and M1708. The Model 1730 provides 455 digital and analog inputs/outputs and supports up to 150 RTUs. With the power to serve dual functions as Controller and local terminal unit, the Model 1730 can be configured to monitor co-located equipment.

Last modified January 2003

_1172499252.unknown