Remote Meter Box - Nordson · Remote Meter Box 5 2020 Nordson Corporation Part 1615443-02...
Transcript of Remote Meter Box - Nordson · Remote Meter Box 5 2020 Nordson Corporation Part 1615443-02...
NORDSON CORPORATION • AMHERST, OHIO • USA
For parts and technical support, call the Industrial CoatingSystems Customer Support Center at (800) 433-9319 or
contact your local Nordson representative.
This document is subject to change without notice.Check http://emanuals.nordson.com for the latest version.
Remote Meter Box
Customer Product ManualPart 1615443-03
Issued 10/20
Part 1615443-03 � 2020 Nordson Corporation
tents
Table of ContentsSafety 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Qualified Personnel 1. . . . . . . . . . . . . . . . . . . . . . . . .Intended Use 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Regulations and Approvals 1. . . . . . . . . . . . . . . . . .Personal Safety 2. . . . . . . . . . . . . . . . . . . . . . . . . . . .
High-Pressure Fluids 2. . . . . . . . . . . . . . . . . . . . .Fire Safety 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Halogenated Hydrocarbon Solvent Hazards 4.Action in the Event of a Malfunction 4. . . . . . . . . . .Disposal 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Description 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Installation 6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
RMB and Pro-Meter® S PLC Assembly MountingInstructions 6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Accurate Mount Positioning Required 6. . . . . . .Accurate Mount Position Not Required 6. . . . . .10.80 x 11.75 Mounting Plate Dimensions 8. . .13.75 x 17.00 Mounting Plate Dimensions 9. . .Ambient/TCU RMB Connections 10. . . . . . . . . . .120 V RMB Connections 11. . . . . . . . . . . . . . . . .240 V RMB Connections 12. . . . . . . . . . . . . . . . .
Operation 13. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Replacing or Removing the RMB 14. . . . . . . . . . . . . .RMB Parts 15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Modules 15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Parts 16. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Valve, Transducer, and Mounting Parts 16. . . . . . . .Box 18. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .RMB Cables 20. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Ethernet Cables 20. . . . . . . . . . . . . . . . . . . . . . . . . . . .Coherix Vision Power Cables (if equipped) 21. . . . .Consumables 21. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Application Specific Components 21. . . . . . . . . . . . .
Pneumatic Control Schematic 22. . . . . . . . . . . . . . . .Electric Schematics 22. . . . . . . . . . . . . . . . . . . . . . . . . .
Contact UsNordson Corporation welcomes requests for information, comments, andinquiries about its products. General information about Nordson can befound on the Internet using the following address:http://www.nordson.com.Address all correspondence to:
Nordson CorporationAttn: Customer Service555 Jackson StreetAmherst, OH 44001
NoticeThis is a Nordson Corporation publication which is protected by copyright.Original copyright date 2020. No part of this document may bephotocopied, reproduced, or translated to another language without theprior written consent of Nordson Corporation. The information containedin this publication is subject to change without notice.
Trademarks
Pro-Meter, Nordson, and the Nordson logo are registered trademarks ofNordson Corporation.
Process Sentry is a trademark of the Nordson Corporation.
All other trademarks are the property of their respective owners.
Change Record i
Part 1615443-02� 2019 Nordson Corporation
Change RecordRevision Date Change
01 01/19 Initial release.
02 05/20 Cable update, 120 V RMB box update from four zones to six zones
03 10/20 Cable update, adding additional cables and lengths
Change Recordii
Part 1615443-02 � 2019 Nordson Corporation
Remote Meter Box 1
Part 1615443-02� 2020 Nordson Corporation
Remote Meter Box
Safety Read and follow these safety instructions. Task- and equipment-specificwarnings, cautions, and instructions are included in equipmentdocumentation where appropriate.
Make sure all equipment documentation, including these instructions, isaccessible to persons operating or servicing equipment.
Qualified Personnel Equipment owners are responsible for making sure that Nordson equipmentis installed, operated, and serviced by qualified personnel. Qualifiedpersonnel are those employees or contractors who are trained to safelyperform their assigned tasks. They are familiar with all relevant safety rulesand regulations and are physically capable of performing their assignedtasks.
Intended Use Use of Nordson equipment in ways other than those described in thedocumentation supplied with the equipment may result in injury to personsor damage to property.
Some examples of unintended use of equipment include
� using incompatible materials
� making unauthorized modifications
� removing or bypassing safety guards or interlocks
� using incompatible or damaged parts
� using unapproved auxiliary equipment
� operating equipment in excess of maximum ratings
Regulations and Approvals Make sure all equipment is rated and approved for the environment in whichit is used. Any approvals obtained for Nordson equipment will be voided ifinstructions for installation, operation, and service are not followed.
Remote Meter Box2
Part 1615443-02 � 2020 Nordson Corporation
Personal Safety To prevent injury follow, these instructions.
� Do not operate or service equipment unless you are qualified.
� Do not operate equipment unless safety guards, doors, or covers areintact and automatic interlocks are operating properly. Do not bypass ordisarm any safety devices.
� Keep clear of moving equipment. Before adjusting or servicing movingequipment, shut off the power supply and wait until the equipmentcomes to a complete stop. Lock out power and secure the equipment toprevent unexpected movement.
� Relieve (bleed off) hydraulic and pneumatic pressure before adjusting orservicing pressurized systems or components. Disconnect, lock out,and tag switches before servicing electrical equipment.
� While operating manual spray guns, make sure you are grounded.Wear electrically conductive gloves or a grounding strap connected tothe gun handle or other true earth ground. Do not wear or carry metallicobjects such as jewelry or tools.
� If you receive even a slight electrical shock, shut down all electrical orelectrostatic equipment immediately. Do not restart the equipment untilthe problem has been identified and corrected.
� Obtain and read Safety Data Sheets (SDS) for all materials used.Follow the manufacturer’s instructions for safe handling and use ofmaterials, and use recommended personal protection devices.
� Make sure the spray area is adequately ventilated.
� To prevent injury, be aware of less-obvious dangers in the workplacethat often cannot be completely eliminated, such as hot surfaces, sharpedges, energized electrical circuits, and moving parts that cannot beenclosed or otherwise guarded for practical reasons.
High-Pressure Fluids High-pressure fluids, unless they are safely contained, are extremelyhazardous. Always relieve fluid pressure before adjusting or servicing highpressure equipment. A jet of high-pressure fluid can cut like a knife andcause serious bodily injury, amputation, or death. Fluids penetrating theskin can also cause toxic poisoning.
If you suffer a fluid injection injury, seek medical care immediately. Ifpossible, provide a copy of the SDS for the injected fluid to the health careprovider.
Remote Meter Box 3
Part 1615443-02� 2020 Nordson Corporation
The National Spray Equipment Manufacturers Association has created awallet card that you should carry when you are operating high-pressurespray equipment. These cards are supplied with your equipment. Thefollowing is the text of this card:
WARNING: Any injury caused by high pressure liquid can be serious. Ifyou are injured or even suspect an injury:
� Go to an emergency room immediately.
� Tell the doctor that you suspect an injection injury.
� Show them this card
� Tell them what kind of material you were spraying
MEDICAL ALERT—AIRLESS SPRAY WOUNDS: NOTE TO PHYSICIAN
Injection in the skin is a serious traumatic injury. It is important to treat theinjury surgically as soon as possible. Do not delay treatment to researchtoxicity. Toxicity is a concern with some exotic coatings injected directly intothe bloodstream.
Consultation with a plastic surgeon or a reconstructive hand surgeon maybe advisable.
The seriousness of the wound depends on where the injury is on the body,whether the substance hit something on its way in and deflected causingmore damage, and many other variables including skin microflora residingin the paint or gun which are blasted into the wound. If the injected paintcontains acrylic latex and titanium dioxide that damage the tissue’sresistance to infection, bacterial growth will flourish. The treatment thatdoctors recommend for an injection injury to the hand includes immediatedecompression of the closed vascular compartments of the hand to releasethe underlying tissue distended by the injected paint, judicious wounddebridement, and immediate antibiotic treatment.
Fire Safety To avoid a fire or explosion, follow these instructions.
� Ground all conductive equipment. Use only grounded air and fluidhoses. Check equipment and workpiece grounding devices regularly.Resistance to ground must not exceed one megohm.
� Shut down all equipment immediately if you notice static sparking orarcing. Do not restart the equipment until the cause has been identifiedand corrected.
� Do not smoke, weld, grind, or use open flames where flammablematerials are being used or stored.
� Do not heat materials to temperatures above those recommended bythe manufacturer. Make sure heat monitoring and limiting devices areworking properly.
Remote Meter Box4
Part 1615443-02 � 2020 Nordson Corporation
Fire Safety (contd)
� Provide adequate ventilation to prevent dangerous concentrations ofvolatile particles or vapors. Refer to local codes or your material SDSfor guidance.
� Do not disconnect live electrical circuits when working with flammablematerials. Shut off power at a disconnect switch first to preventsparking.
� Know where emergency stop buttons, shutoff valves, and fireextinguishers are located. If a fire starts in a spray booth, immediatelyshut off the spray system and exhaust fans.
� Shut off electrostatic power and ground the charging system beforeadjusting, cleaning, or repairing electrostatic equipment.
� Clean, maintain, test, and repair equipment according to the instructionsin your equipment documentation.
� Use only replacement parts that are designed for use with originalequipment. Contact your Nordson representative for parts informationand advice.
Halogenated Hydrocarbon Solvent Hazards Do not use halogenated hydrocarbon solvents in a pressurized system thatcontains aluminum components. Under pressure, these solvents can reactwith aluminum and explode, causing injury, death, or property damage.Halogenated hydrocarbon solvents contain one or more of the followingelements:
Element Symbol Prefix
Fluorine F “Fluoro-”
Chlorine Cl “Chloro-”
Bromine Br “Bromo-”
Iodine I “Iodo-”
Check your material SDS or contact your material supplier for moreinformation. If you must use halogenated hydrocarbon solvents, contactyour Nordson representative for information about compatible Nordsoncomponents.
Action in the Event of a Malfunction If a system or any equipment in a system malfunctions, shut off the systemimmediately and perform the following steps:
� Disconnect and lock out system electrical power. Close hydraulic andpneumatic shutoff valves and relieve pressures.
� Identify the reason for the malfunction and correct it before restarting thesystem.
Disposal Dispose of equipment and materials used in operation and servicingaccording to local codes.
Remote Meter Box 5
Part 1615443-02� 2020 Nordson Corporation
Description See Figure 1.
The Remote Meter Box (RMB) is designed to provide communicationbetween the Pro−Meter® S PLC System and the Process Sentry� PLCController.
The RMB Module is used with a Process Sentry PLC controller.Adjustments at the system controller enclosure can be used to change themotor speed and affect the desired pump flow rate. For information on thesystem controller, refer to the Process Sentry PLC Controller manual.
Ambient/TCU
120 V
240 V
Figure 1 Remote Meter Box
Remote Meter Box6
Part 1615443-02 � 2020 Nordson Corporation
Installation
RMB and Pro-Meter� S PLC Assembly Mounting InstructionsMount the RMB and Pro-Meter® S PLC dispenser to the robot/pedestalusing mounting plate on the bottom of the assembly.
The 10.80 in. x 11.25 in. plate is used for configurations using the S15, S35,and S100 Pro-Meter® S PLC dispensers while the S165 and S300configurations use the 13.75 in. x 15.50 in. mounting plate.
There are two sets of mounting holes on each of the mounting plates.
Accurate Mount Positioning RequiredThe first set is used when an accurate positioning of the assembly isrequired. This mounting set includes four threaded inserts and two dowelpins to maintain positive positioning even during maintenance and repair.
Accurate Mount Position Not RequiredThe second set of mounting holes is used when accurate positioning of theassembly is not required, typically when the assembly is mounted on thearm of a robot or on a pedestal and the dispensing gun is mounted on therobot wrist. This mounting set includes six holes; three at each end of themounting plate.
Choose the proper mounting set-up and refer to the applicable mountingplate and applicable mounting holes in Figure 2 for mounting locations.
Remote Meter Box 7
Part 1615443-02� 2020 Nordson Corporation
11.25 in.
13.75 in.
10.80 in.
15.50 in.
11.25 in.
13.75 in.
10.80 in.
15.50 in.
Accurate Position Required
Accurate Position Not Required
= Mounting holes = Dowel Pins
Figure 2 RMB and Pro−Meter® PLC Assembly Mounting Instructions
Remote Meter Box8
Part 1615443-02 � 2020 Nordson Corporation
10.80 x 11.75 Mounting Plate Dimensions
C
A
B
G
H
B
.750
5.625
10.875
.626
9.750
4.079
9.361
4 X .413 THRU2 X M10 X 1.5 - 6H THRU ALL
2 X .250
1.781
1.3001.300
3.250
2 X (0.2503 / .2501 DOWEL PIN)
4 X M8 X 1.25 X 12MM LG INSERT
G
.012
E
CBA
A.015 H
.012 CAM B
.005 A B C
.001 A
Remote Meter Box 9
Part 1615443-02� 2020 Nordson Corporation
13.75 x 17.00 Mounting Plate Dimensions
B
C
E
F
A
2X.3937
.3932 THRU
(Ø.3939 / .3943 DOWEL PIN)
4 X .413 THRU
2.500
15.500
1.250
11.000
1.060
7.040
13.020
2 X M10 X 1.5 - 6H THRU ALL
.750
4.500
2.000
2X .431
C4 X M12 X 1.75 X 16MM LG INSERT
A
B
.001
.012 A CBM
.005 A
.012 M A B C
.015 A E F
Ø
Ø
Remote Meter Box10
Part 1615443-02 � 2020 Nordson Corporation
Ambient/TCU RMB Connections See Figure 3 and refer to the following table.
5
6
4b
6
7
5
8
7
9
4a/4b4a
3
3
1
2
Figure 3 Ambient/TCU RMB Connections
Item Description
1 Transducer Connection
2 TCU RTD
3 Vision Connections (If equipped)
4a Refill Valve Connection
4b Dispense Valve Connection
5 AC Motor Power
6 DC Motor Power
7 Ethernet Connection
8 Controller Connection
9 Nozzle Detect Connection (if equipped)
Remote Meter Box 11
Part 1615443-02� 2020 Nordson Corporation
120 V RMB Connections See Figure 4 and refer to the following table.
9
10
12
7b
9
10
8
7a
2
8
7a/7b
6 5
11
4
4
21
3
Figure 4 120 V RMB Connections
Item Description
1 Transducer Connection
2 Meter/Heat Zone 2
3 Aux Heat Zone 1 (if equipped)
4 Vision Connections (if equipped)
5 Whip Hose and Gun/Heat Zone 3 and 4 (if equipped)
6 Supply Hose/Heat Zone 5 and 6 (if equipped)
7a Refill Valve Connection
7b Dispense Valve Connection
8 AC Motor Power
9 DC Motor Power
10 Ethernet Connection
11 Controller Connection
12 Nozzle Detect Connection (if equipped)
Remote Meter Box12
Part 1615443-02 � 2020 Nordson Corporation
240 V RMB Connections See Figure 5 and refer to the following table.
9
8 11
7a/7b
6 5
8
10
12
7a7b
9
10
2
4
4
1
2
3
Figure 5 240 V RMB Connections
Item Description
1 Transducer Connection
2 Meter/Heat Zone 2
3 Aux Heat Zone 1 (if equipped)
4 Vision Connections (if equipped)
5 Whip Hose and Gun/Heat Zone 3 and 4 (if equipped)
6 Supply Hose/Heat Zone 5 and 6 (if equipped)
7a Refill Valve Connection
7b Dispense Valve Connection
8 AC Motor Power
9 DC Motor Power
10 Ethernet Connection
11 Controller Connection
12 Nozzle Detect Connection (if equipped)
Remote Meter Box 13
Part 1615443-02� 2020 Nordson Corporation
OperationOperation of the remote meter box is dependant on the system it is usedwith. Refer to the applicable manuals of these system parts for operationinstructions.
Remote Meter Box14
Part 1615443-02 � 2020 Nordson Corporation
Replacing or Removing the RMBSee Figure 6.
1
2
34
5
Figure 6 Remote Meter Box removal/replacement.
1. Power down the system control and remove all the connections.
2. Remove the 14 M5 button-head screws (1) securing the side panel (2)to the RMB.
3. Remove the four M8 x 20 socket screws (5), four M8 nylon sealingwashers (4) and four M8 nylock nuts (3).
4. Remove the RMB Module from the mounting plate.
5. Replace the RMB module by reversing steps 1-4.
Remote Meter Box 15
Part 1615443-02� 2020 Nordson Corporation
RMB PartsTo order parts, call the Nordson Industrial Coating Systems CustomerSupport Center at (800) 433-9319 or contact your local Nordsonrepresentative.
Modules Replacement Box
Part NumberRMB Module Types
1614740MODULE, RMB-M, 15-100 cc, ambient heat/TCU
MODULE, RMB-IM, 165-300 cc, ambient heat/TCU
1614741MODULE, RMB-IM, 15-00 cc, ambient heat/TCU, Vision
MODULE, RMB-IM, 165-300 cc, ambient heat/TCU, Vision
1614736
MODULE, RMB-IM, 15 cc, electric heat, 120 V
MODULE, RMB-M, 35-100 cc, electric heat, 120 V
MODULE, RMB-IM, 165-300 cc, electric heat, 120 V
1614737
MODULE, RMB-IM, 15 cc, electric heat, 120 V, Vision
MODULE, RMB-IM, 35-100 cc, electric heat, 120 V, Vision
MODULE, RMB-IM, 165-300 cc, electric heat, 120 V, Vision
1614738
MODULE, RMB-IM, 15 cc, electric heat, 240 V
MODULE, RMB-IM, 35-100 cc, electric heat, 240 V
MODULE, RMB-IM, 165-300 cc, electric heat, 240 V
1614739
MODULE, RMB-IM, 15 cc, electric heat, 240 V, Vision
MODULE, RMB-IM, 35-100 cc, electric heat, 240 V, Vision
MODULE, RMB-IM, 165-300 cc, electric heat, 240 V, Vision
Remote Meter Box16
Part 1615443-02 � 2020 Nordson Corporation
Parts
Valve, Transducer, and Mounting PartsSee Figure 7 and refer to the following table.
1 23
4 5
6
7
8
9
1011
11
Figure 7 Valve, Transducer, and Mounting Parts
Remote Meter Box 17
Part 1615443-02� 2020 Nordson Corporation
Item Part Description Qty Note
1 1612817 SOLENOID COIL, valve, M12 connector, 24 VDC 2
2 320841 ELBOW, male, extended, ¼ T x ¼ NPT 2
3 971266 ELBOW, male, 0.25 tube x 0.25 NPT 2
4 1611530 ASSEMBLY, valve, air, 5/2, 24 VDC 2
5 973411 PLUG, pipe socket, flush, ¼ zinc 3
6 1034396 MUFFLER, exhaust, ¼ NPT male 2
7 105815SCREW, socket, head, M4 x 0.7 x 30 ISO 4762, class 12.9zinc
4
8 982006 SCREW, socket, M8 x 1.25 x 20 ISO 4762, class 12.9 zinc 4 B
8 982382 SCREW, socket, M8 x 1.25 x 40 ISO 4762, class 12.9 zinc 4 A
8 1027235 SCREW, socket, M12 x 1.75 x 30 ISO 4762, class 12.9 zinc 4 C
9 1611703 TRANSDUCER, pressure, 3000 psi., 4-20 mA 1
10 1615332 SPACER, 3.480 x 0.750 x 1 in. thick, Pro-Meter, S15 2 A
11 1001849 GREASE, Mobil™, synthetic, SHC, 100 12.5 oz. AR
NOTE A: 15 cc electric RMB only
B: All 15, 35, and 100 cc RMB except 15 cc electric
C: All 165 and 300 cc RMB
AR: As Required
Remote Meter Box18
Part 1615443-02 � 2020 Nordson Corporation
BoxSee Figure 8 and refer to the following table.
1
5
6
8
9
10
6
7
1
10
165-300 ccConfiguration
15-100 ccConfiguration
2
3
4
Figure 8 Box Parts
Remote Meter Box 19
Part 1615443-02� 2020 Nordson Corporation
Item Part Description 15-100 cc 165-300 cc Note
1 1615820 CABLE, 4-pin micro, 0.5 M, male/female 2 1
2 −−−−−−SCREW, button-head, M5 x 0.8 x 10 , ISO 7380, class10.9 zinc 14 14
3 1612844 NUT, hex lock, nylon, insert, flanged, M8, steel, zinc 4 4
4 1612845WASHER, flat, 8.4 mm ID x 18.0 mm OD x 2 mm thick,nylon 4 4
5 982006SCREW, socket, M8 x 1.25 x 20, ISO 4762, class 12.9zinc 4 4
6 1615819 CABLE, Y, 4-pin micro, 1 male/2 female, 0.3 M 1 1
7
1615854 CABLE, 3-pin mini, 16 AWG, 600 V, 0.5 M 1 —
A1617857 CABLE, 3-pin mini, 16 AWG, 600 V, 2 M 1 —
1618987 CABLE, 3-pin mini, 16 AWG, 600 V, 4 M 1 —
8 1615855 CABLE, 3-pin mini, 16 AWG, 600 V, 1 M — 1
91615821 CABLE, 4-pin micro, 1 m, male/female
— 1 A1619872 CABLE, 4-pin micro, 30 m, male/female
101615843 CABLE, 4-pin, M12, ethernet, 0.5 M, black 1 —
1615844 CABLE, 4-pin, M12, ethernet, 1 M, black — 1NOTE A: Cable length is dependant on system configuration.
Remote Meter Box20
Part 1615443-02 � 2020 Nordson Corporation
RMB Cables
Item Description1614314 CABLE, Pro-Meter S, RMB, main, 4 m1614315 CABLE, Pro-Meter S, RMB, main, 6 m1614316 CABLE, Pro-Meter S, RMB, main, 8 m1614317 CABLE, Pro-Meter S, RMB, main, 10 m1614318 CABLE, Pro-Meter S, RMB, main, 12 m1614319 CABLE, Pro-Meter S, RMB, main, 15 m1614320 CABLE, Pro-Meter S, RMB, main, 18 m1612754 CABLE, Pro-Meter S, RMB, main, 22 m1619354 CABLE, Pro-Meter S, RMB, main, 23 m1619355 CABLE, Pro-Meter S, RMB, main, 25 m1619356 CABLE, Pro-Meter S, RMB, main, 27 m1619357 CABLE, Pro-Meter S, RMB, main, 30 m1619358 CABLE, Pro-Meter S, RMB, main, 32 m1619359 CABLE, Pro-Meter S, RMB, main, 35 m1619360 CABLE, Pro-Meter S, RMB, main, 40 m1614322 CABLE, Pro-Meter S, RMB, robot cables (sacrificial), 3 m1614323 CABLE, Pro-Meter S, RMB, robot cables (sacrificial), 4 m1614324 CABLE, Pro-Meter S, RMB, robot cables (sacrificial), 6 m1612755 CABLE, Pro-Meter S, RMB, robot cables (sacrificial), 8 m
Ethernet CablesItem Description
1615832 CABLE, 4-Pin M12, ethernet, 0.5 m, teal1615833 CABLE, 4-Pin M12, ethernet, 1 m, teal1615834 CABLE, 4-Pin M12, ethernet, 2 m, teal1615835 CABLE, 4-Pin M12, ethernet, 3 m, teal1615836 CABLE, 4-Pin M12, ethernet, 4 m, teal1615837 CABLE, 4-Pin M12, ethernet, 6 m, teal1615838 CABLE, 4-Pin M12, ethernet, 8 m, teal1615839 CABLE, 4-Pin M12, ethernet, 10 m, teal1615840 CABLE, 4-Pin M12, ethernet, 12 m, teal1615841 CABLE, 4-Pin M12, ethernet, 15 m, teal1615842 CABLE, 4-Pin M12, ethernet, 18 m, teal1615845 CABLE, 4-Pin M12, ethernet, 2 m, blue1615846 CABLE, 4-Pin M12, ethernet, 3 m, blue1615847 CABLE, 4-Pin M12, ethernet, 4 m, blue1615848 CABLE, 4-Pin M12, ethernet, 6 m, blue1615849 CABLE, 4-Pin M12, ethernet, 8 m, blue1615850 CABLE, 4-Pin M12, ethernet, 10 m, blue1615851 CABLE, 4-Pin M12, ethernet, 12 m, blue1615852 CABLE, 4-Pin M12, ethernet, 15 m, blue1615853 CABLE, 4-Pin M12, ethernet, 18 m, blue
Remote Meter Box 21
Part 1615443-02� 2020 Nordson Corporation
Coherix Vision Power Cables (if equipped)Item Description
1615856 CABLE, 12-Pin M12, 24 AWG, 0.3 m, male/female1615857 CABLE, 12-Pin M12, 24 AWG, 0.5 m, male/female1615858 CABLE, 12-Pin M12, 24 AWG, 1 m, male/female1615859 CABLE, 12-Pin M12, 24 AWG, 2 m, male/female1615860 CABLE, 12-Pin M12, 24 AWG, 3 m, male/female1615861 CABLE, 12-Pin M12, 24 AWG, 4 m, male/female1615862 CABLE, 12-Pin M12, 24 AWG, 5 m, male/female1615863 CABLE, 12-Pin M12, 24 AWG, 6 m, male/female
ConsumablesAdhesives and lubricants to use where instructed on the Remote Meter Box.
Part Description900464 ADHESIVE, Loctite 242�, blue, removable, 50 mm1001849 GREASE, Mobil�, synthetic, SHC100, 12.5 oz900481 ADHESIVE, pipe/thread/hydraulic sealant (PST)
Application Specific Components
Part Description1612891 SPACER, 3.00 in. square, 1 in. thick (used for mounting RMB/Pro−Meter to pedestal arm)982160 SCREW, socket, M8 x 1.25 x 25, ISO 4762, class 12.9 zinc
Remote Meter Box22
Part 1615443-02 � 2020 Nordson Corporation
Pneumatic Control Schematic See Figure 9.
12
REGULAR AUTO-FLO
ANTI-DROOL AUTO-FLO
12
42
DISPENSE VALVE
OPEN
CLO
SE
3
CLO
SE
SUPPLY PRESSURE
4
5
OPEN
2
1
REFILL VALVE
1
2
OPEN
DISPENSESOLENOIDVALVE5
4
SUPPLY PRESSURE
CLO
SE
3
CLO
SEO
PEN
DISPENSE VALVE
24
REFILLSOLENOIDVALVE 12 12
DISPENSESOLENOIDVALVE
REFILLSOLENOIDVALVE
REFILL VALVE
Figure 10 Pneumatic Control Schematic
Electric SchematicsThe electric schematics are available with the system documentation.