Page 1: R-D Herzberg The SAGE Spectrometer The next four years.

R-D Herzberg

The SAGE Spectrometer

The next four years

Page 2: R-D Herzberg The SAGE Spectrometer The next four years.

R-D Herzberg

Overview

• Brief Physics Case

• Technical description

• Work to be done

Page 3: R-D Herzberg The SAGE Spectrometer The next four years.

R-D Herzberg

Physics

• In heavy nuclei Gamma rays and conversion electrons compete.

E.g. for Z~100:

• E2: Conversion is dominant above 400 keV

• M1: Conversion is dominant above 200 keV

Page 4: R-D Herzberg The SAGE Spectrometer The next four years.

R-D Herzberg

Physics

• Any heavy (trans-)actinide nucleus must be studied twice:

gammas and electrons

• SAGE allows the simultaneous investigation of gamma rays and conversion electrons in the same experiment!

Page 5: R-D Herzberg The SAGE Spectrometer The next four years.

R-D Herzberg

Why us?

• We’ve done Juroshpere/gam• Dito SACRED• Dito GREAT• Dito TDR• Dito a lot of heavy element work

• A lot of experience and expertise is collected in this room!

Page 6: R-D Herzberg The SAGE Spectrometer The next four years.

R-D Herzberg

Ingredients

• Ge – Array John, Pete • Solenoid Paul, Juha

• Si – detector Rodi, Robert

• Electronics Ian, Jim, Patrick, Dave

• Mechanics Dave

• Software John, Simon, Vic

Page 7: R-D Herzberg The SAGE Spectrometer The next four years.

R-D Herzberg

Technical details

Page 8: R-D Herzberg The SAGE Spectrometer The next four years.

R-D Herzberg

Ge array

What shape do we want Jurogam to take in the future?

As is?

Clovers?

Page 9: R-D Herzberg The SAGE Spectrometer The next four years.

R-D Herzberg

Solenoid

• Need to efficiently transport the electrons from the target to the detector

• Must not interfere with Ge detectors

• Tricky: need optimisation

Page 10: R-D Herzberg The SAGE Spectrometer The next four years.

R-D Herzberg

Si detector

• High pixellation

• Rate distribution

• High rate capability

Page 11: R-D Herzberg The SAGE Spectrometer The next four years.

R-D Herzberg

Electronics

• DIGITAL

• TNT2 tests have been done

• Total capability up by a factor 12: 4 x segmentation, 3 x rate/pixel

• Huge data rates!

Page 12: R-D Herzberg The SAGE Spectrometer The next four years.

R-D Herzberg

Mechanics

• Target chamber• Solenoid support• Si detector chamber• Ge frame• Target wheel

• Windowless operation?

Page 13: R-D Herzberg The SAGE Spectrometer The next four years.

R-D Herzberg

2005 2006 2007 2008 2009

Q2

Q3

Q4

Q1

Q2

Q3

Q4

Q1

Q2

Q3

Q4

Q1

Q2

Q3

Q4

Q1

Q2

Q3

Conceptual and mechanical design of SAGE                  

Manufacture, testing and installation                

Electronics design and implementation                    

Support of experimental programme                                  

GREAT, JUROGAM, SACRED exploitation                                  

SAGE + GREAT exploitation                        

Data analysis and dissemination