Eco Material
www.pentens.com
Energy Saving Thermal Insulation Wall
Eco Material Spray Thermal Insulation System
Eco Construction Chemicals
In line with the latest world trend and Taiwan
Government policy of Green Building Materials
development, PENTENS continues to promote
its product orientation:
� Ecology
� Energy Saving
� Waste Reduction
� Health
Eco Material Spray Thermal Insulation System
Eco Construction Chemicals
Energy
Saving
Material
ES-Coat Energy Saving Coating
Thermal Insulation Wall
Spray Polyurethane Insulation Foam
ES Coat Spray Thermal Insulation System
Eco Construction Chemicals
• High performance energy saving coatingsystem
• High reflectivity • Low thermal conductivity• Low emissivity • Block heat and radiation
• Free from corrosion, toxicity & carcinogenicity
• Water-based, without emanate any pollutant
• Frost-proof and dew-proof
• Air-conditioning saving
• High mechanical strength
Heat Transfer Methods Spray Thermal Insulation System
Eco Construction Chemicals
Heat transfers in three ways:
1.Conduction
2.Convection
3.Radiation
Heat travels through a “material”
� Conduction
Heat travels through
a “liquid” or a “gas”
particle
� Convection
Radiation requires NO particles to travel
Conductor
Insulator
Convection
Radiation
Conduction
Heat Transfer Methods Spray Thermal Insulation System
Eco Construction Chemicals
Indoor/Outdoor heat source in Summer
Ground 8.2%
Negative side
window 1.5%
Wall 18.2%
Roof/Ceiling 22.8%
Positive side
window 23%
Adequately
ventilated 13%
Heat source
from indoor 13.3%
So, how does heat energy reach the
Earth from the Sun?
There are no particles between the
Sun and the Earth so it CANNOT
travel by conduction or by convection.
?
� Radiation
Energy Saving Coating System Spray Thermal Insulation System
Eco Construction Chemicals
•Water-based
•Single component
•Low thermal
conductivity (“K”
value)
•Aerogel added
•Paintable, rollable
•Anti-corrosion
•Non-flammable
•Non metallic type
•High heat reflectivity
•Shinny white color
•Excellent weather
resistance
•No oxidation
•Low emissivity
•Metallic sheen
•Radiant barrier
•Save significant
energy in buildings
•Water-based
•Low VOC
Hi-R Lo-K Lo-E
How does it work?
Hi-R - High Reflective Coating Spray Thermal Insulation System
Eco Construction Chemicals
Q1: Which is the best surface for reflecting heat
radiation?
Shiny white Dull white Dull black Shiny black
Q2: Which is the best surface for absorbing heat
radiation?
Q1 Q2
That’s why houses are painted white in hot countries...
White reflects heat radiation and keeps the house cooler.
This is a list of approximate
values of thermal conductivity,
“K” value, for some common
materials.
The lower the K-
value the better the
thermal insulating
properties.
Material Thermal conductivity
W/(m·K)
Silica Aero Gel 0.004~0.03
Air 0.025
Wood 0.04~0.4
Water (liquid) 0.6
Glass 1.1
Soil 1.5
Concrete 1.7
Ice 2
Stainless steel 12.11~45.0
Aluminum 237
Gold 318
Copper 401
Silver 429
Diamond 900~2320
Aero gel 航空凝胶
Spray Thermal Insulation System
Eco Construction ChemicalsLo-K- Aerogel Insulating Coating
Lo-E - Aluminum Coating Spray Thermal Insulation System
Eco Construction Chemicals
Which is the best surface for reflecting heat
radiation and has lower emittance?
That’s why shiny foil blankets are wrapped around marathon
runners at the end of a race...
The shiny metal reflects the heat radiation from the runner
back in, this stops the runner getting cold.
Shiny white Dull white Dull metal Shiny metal
Energy Saving Coating System Spray Thermal Insulation System
Eco Construction Chemicals
1mm High SRI Ceramic Coating
1.5mm Waterproofing Layer
Primer: Water-based Aluminum Coating
Features & Benefits:
• Hi-R, Lo-K & Lo-E system,
promotes energy
efficiency.
• Waterproof, durable
• Water-based, Eco Friendly
(block invisible light – far-infrared heat)
(reflect > 95% sunlight)
Energy Saving Coating System Spray Thermal Insulation System
Eco Construction Chemicals
Case study 1
Uncoated 46.40C Coated 36.40C (Surface temp. drops 100C)
Energy Saving Coating System Spray Thermal Insulation System
Eco Construction Chemicals
Case study 2
Uncoated 53.30C Coated 43.70C (Surface temp. drops 9.60C)
Spray Polyurethane Insulation Foam
� High Level of R-Value
� Lightweight & High
Strength
� Excellent Insulating
Abilities
� Improve Energy
Efficiency
� Deadens Sound Travel
& Noise
� Control Moisture &
Condensation
Spray Thermal Insulation System
Eco Construction Chemicals
� Flat Roof
� External &
Internal Walls
� Basement Soffit
� Pitched roofs
�Internal Soffit
Insulation
� Internal
industrial roofing
Spray Thermal Insulation System
Eco Construction ChemicalsSpray Polyurethane Insulation Foam
Spray Thermal Insulation System
Eco Construction ChemicalsSection Drawings – Flat Roof
K-Value, R-Value & U-Value Spray Thermal Insulation System
Eco Construction Chemicals
1. Thermal Conductivity (K-Value)
The ability of a material to transmit heat is measured by its
thermal conductivity or K-value. It is expressed in W/(m°K)
K-value = 0.0272 W/(m°K)
2. Thermal Resistance (R-Value)
The thermal resistance of a material or construction is the
reciprocal of its thermal conductance. It is expressed in
m2°K/W and is given by:
R =
Where L is the thickness of the material.
L
K
K-Value, R-Value & U-Value Spray Thermal Insulation System
Eco Construction Chemicals
3. Thermal Transmittance (U-Value)
The thermal transmittance or U-value of a construction is
defined as the quantity of heat that flows through a unit
area of a building section under steady-state conditions in
unit time per temperature difference of the air on either
side of the section. It is expressed in W/(m2°K) and is
given by:
U =
Where RT is the total thermal resistance.
The higher the R, the lower the U, the better.
1
RT
GBI Requirement of Roof U-Value
Roof Weight
Group
Maximum U-Value
(W/m2K)
Light (Under 50
kg/m2)
0.4
Heavy (Above 50
kg/m2)
0.6
MS1525:2007 Clause 5.5.1The roof of a conditioned space shall not have a thermal
transmittance (U-value) greater than that tabulated in Table 9.
Spray Thermal Insulation System
Eco Construction Chemicals
Table 9. Maximum U-value for roof (W/m2K)
R.C Roof WITHOUT insulation THERMAL
CONDUCTIVITY
(W.mK)
R - THERMAL
RESISTANCE
(m2 K/W)
1 External surface - 0.040
2 Cement screed, 50mm thk 0.41 0.122
3 Waterproof membrane 0.23 0.004
4 R.C Slab, 150mm thk 2.30 0.065
5 Internal surface - 0.130
0.362Total R
Before, U-Value =
=
= 2.762 W/m2k
Spray Thermal Insulation System
Eco Construction ChemicalsRoof U-value (Before)
Note: System compared based on same material (as refer to GBI). Variant on different material using.
1
R
1
0.362
THERMAL
CONDUCTIVITY
(W.mK)
R - THERMAL
RESISTANCE
(m2 K/W)
1 External surface - 0.040
2 Cement screed, 50mm thk 0.41 0.122
3 Waterproof membrane 0.23 0.004
4 50mm thk Pentens PU-130 0.0272 1.838
5 R.C Slab, 150mm thk 2.30 0.065
6 Internal surface - 0.130
2.199
R.C Roof WITH insulation
Improved U-Value =
=
= 0.455 W/m2k
Total R
Spray Thermal Insulation System
Eco Construction ChemicalsRoof U-value (Improved)
4
Note: System compared based on same material (as refer to GBI). Variant on different material using.
1
R
1
2.199
Winter Summer
Cool Air Warm Air
Reflection Reflection
Reflection
Reflection
Reflection
Reflection
ReflectionReflection
Earthy Air Earthy Air
Warm Air Cool Air
Spray Thermal Insulation System
Eco Construction ChemicalsSpray Polyurethane Insulation Foam
Thermal Insulation Wall Spray Thermal Insulation System
Eco Construction Chemicals
This thermal
Insulation wall is a
lightweight thermal
insulation material
which made of
vitrified material,
mixed with
cementitious powder,
anti cracking
additives and other
ingredients,
produced in a ready-
Thermal Insulation Wall
� Low thermal
conductivity
(0.070 W/(m°K)
� Lightweight & High
Strength
� Good Insulating
Abilities
� Energy Saving
� Easy application
� Durable & Non-
flammable
Spray Thermal Insulation System
Eco Construction Chemicals
Thermal Insulation Wall
A simple simulation have carried out to study what
benefits the thermal plaster will bring to the
customers with respect to annual energy savings and
improvement of thermal comfort.
Spray Thermal Insulation System
Eco Construction Chemicals
Case study 1:
Plan View Elevation View
Thermal Insulation Wall
Shading Device:
- External shading
device has been
assumed for all three
rooms.
- Internal roller blind has
been provided.
Spray Thermal Insulation System
Eco Construction Chemicals
Thermal Insulation Wall Spray Thermal Insulation System
Eco Construction Chemicals
Intermittent AC Scenario - West Room ( Monday)
(Air Conditioning Hour : 9pm – 7am)
34
33
32
31
30
29
28
27
26
25
24
23
OperativeTemperature
(degC)
S1_No insulation S2_20mm Thermal Plaster S3_40mm Thermal Plaster
S4_60mm Thermal Plaster Outdoor Temperature
Figure 1: Operative Temperature for West room on Monday (Overcast sky)
Thermal Insulation Wall Spray Thermal Insulation System
Eco Construction Chemicals
OperativeTemperature(degC)
35
34
33
32
31
30
29
28
27
26
25
24
S1_No insulation S2_20mm Thermal Plaster S3_40mm Thermal Plaster
S4_60mm Thermal Plaster Outdoor Temperature
Intermittent AC Scenario - West Room ( Monday)
(Air Conditioning Hour : 9pm – 7am)
Figure 2: Operative temperature for West room on Monday (Sunny Day)
Thermal Insulation Wall Spray Thermal Insulation System
Eco Construction Chemicals
Non AC Scenario - West Room ( Monday)
Figure 3: Operative temperature for West room on Monday (Overcast Day)
OperativeTemperature
(degC) 34
33
32
31
30
29
28
27
26
25
24
23
S1_No insulation S2_20mm Thermal Plaster S3_40mm Thermal Plaster
S4_60mm Thermal Plaster Outdoor Temperature
Thermal Insulation Wall Spray Thermal Insulation System
Eco Construction Chemicals
Non AC Scenario - West Room ( Monday)
Figure 4: Operative temperature for West room on Monday (Sunny Day)
OperativeTemperature(degC)
35
34
33
32
31
30
29
28
27
26
25
24
S1_No insulation S2_20mm Thermal Plaster S3_40mm Thermal Plaster
S4_60mm Thermal Plaster Outdoor Temperature
Thermal Insulation Wall Spray Thermal Insulation System
Eco Construction Chemicals
Simulation Scenarios Total AnnualEnergy
Consumption(kWh)
Annualenergysaving
compared toBase( kWh)
AnnualEnergysaving
( kWh/m2
of wall)
AnnualEnergy
Cost (RM)
AnnualMonetarysavings
( RM/m2 ofexternal wall)
Annual EnergySavings for
Typical House
floor area of100m2 (RM)
S1: No Insulation (Base) 6,045 - - 2188 -
S2:20mm Thermal
Plaster
5,919 126 2.33 2120 1.26 126
S3:40mm Thermal
Plaster
5,874 171 3.16 2098 1.66 166
S4: 60mm ThermalPlaster
5,854 191 3.54 2089 1.83 183
Table 10: Total Annual Energy Consumption and energy saving
Thermal Insulation Wall Spray Thermal Insulation System
Eco Construction Chemicals
OTTV FORMULA – For Fenestration at each given orientation
Heat gain from
conductance
through walls
Heat gain from
conductance
through windows
Solar heat gain
through the
glazing
Where,
WWR is the window-to-gross exterior wall area ratio for the orientation under consideration;
α is the solar absorptivity of the opaque wall;
UW is the thermal transmittance of opaque wall (W/m2 K);
Uf is the thermal transmittance of fenestration system (W/m2 K);
CF is the solar correction factor; as in Table 1; and
SC is the shading coefficient of the fenestration system
Plastered Brick Wall THERMAL
CONDUCTIVITY
(W.mK)
R - THERMAL
RESISTANCE
(m2 K/W)
1 External surface - 0.550
2 External plaster, 13mm 0.57 0.023
3 Brick 0.77 0.130
4 Indoor plaster, 13mm thk 0.57 0.023
5 Internal surface - 0.130
0.360Total R
Before, U-Value =
=
= 2.774 W/m2k
Spray Thermal Insulation System
Eco Construction ChemicalsWall U-value (Before)
Note: System compared based on same material (as refer to GBI). Variant on different material using.
1
R
1
0.360
Thermal Plastered Brick Wall
Improved U-Value =
=
= 1.604 W/m2k
Spray Thermal Insulation System
Eco Construction ChemicalsWall U-value (Improved)
Note: System compared based on same material (as refer to GBI). Variant on different material using.
1
R
1
0.623
THERMAL
CONDUCTIVITY
(W.mK)
R - THERMAL
RESISTANCE
(m2 K/W)
1 External surface - 0.550
2 Thermal plaster, 13mm 0.07 0.286
3 Brick 0.77 0.130
4 Indoor plaster, 13mm thk 0.57 0.023
5 Internal surface - 0.130
0.623Total R2
Thermal Plastered Wall
Spray Thermal Insulation System
Eco Construction ChemicalsWall U-value
U-Values
(W/m2.K)
Percent
Improvement
1 Base 2.774 -
2 Thermal plaster, 20mm 1.604 42%
3 Thermal plaster, 40mm 1.100 60%
4 Thermal plaster, 60mm 0.837 70%
www.pentens.com
Hand in Hand, Together We Growth!