PANTHER: WASTE AND CONTAMINATION MANAGEMENT Mr. Todd Richmond –Hologic Marketing

Transcript of PANTHER: WASTE AND CONTAMINATION MANAGEMENT · • Plasma: EDTA, ACD, PPT • Serum: SST, serum...

Page 1: PANTHER: WASTE AND CONTAMINATION MANAGEMENT · • Plasma: EDTA, ACD, PPT • Serum: SST, serum tubes Secondary Tube Sampling • Minimum of 700 μLplasma / serum required with HologicSpecimen

PANTHER: WASTE AND CONTAMINATION MANAGEMENT

Mr. Todd Richmond – Hologic Marketing

Page 2: PANTHER: WASTE AND CONTAMINATION MANAGEMENT · • Plasma: EDTA, ACD, PPT • Serum: SST, serum tubes Secondary Tube Sampling • Minimum of 700 μLplasma / serum required with HologicSpecimen

HOLOGIC

Women’s Health Company

Diagnostics

Cervical Health

Breast / Skeletal health

Global Access Initiative

Page 3: PANTHER: WASTE AND CONTAMINATION MANAGEMENT · • Plasma: EDTA, ACD, PPT • Serum: SST, serum tubes Secondary Tube Sampling • Minimum of 700 μLplasma / serum required with HologicSpecimen

PANTHER SYSTEM AND HIV-1 ASSAY

Page 4: PANTHER: WASTE AND CONTAMINATION MANAGEMENT · • Plasma: EDTA, ACD, PPT • Serum: SST, serum tubes Secondary Tube Sampling • Minimum of 700 μLplasma / serum required with HologicSpecimen

The Panther system provides the following advantages:

PANTHER SYSTEM

• Random and Continuous Access

• Consolidated menu that combines Viral load, Women’s Health and STI testing

• Ability to run assays simultaneously

• Proven Flexibility, Reliability and Performance

• Small footprint saves space and costs; suited for scalability and redundancy

• Panther serves as a foundation for future capabilities and content

Page 5: PANTHER: WASTE AND CONTAMINATION MANAGEMENT · • Plasma: EDTA, ACD, PPT • Serum: SST, serum tubes Secondary Tube Sampling • Minimum of 700 μLplasma / serum required with HologicSpecimen

FULL AUTOMATION FROM SAMPLE-TO-RESULT

Maximize ProductivitySample Preparation

Extraction

Amplification & Detection

ResultsAnalysis

Tota l Automat ion on a S ing le Ins t rument

Page 6: PANTHER: WASTE AND CONTAMINATION MANAGEMENT · • Plasma: EDTA, ACD, PPT • Serum: SST, serum tubes Secondary Tube Sampling • Minimum of 700 μLplasma / serum required with HologicSpecimen

REAL-TIME TMA THROUGHPUT AND CAPACITY

0 020

80

140

200

260

320

380

440

500

560

620

680

740

0

100

200

300

400

500

600

700

800

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

NU

MB

ER

OF

RESU

LTS

NU

MB

ER

OF

RESU

LTS

NU

MB

ER

OF

RESU

LTS

NU

MB

ER

OF

RESU

LTS

TIME (HOURS)TIME (HOURS)TIME (HOURS)TIME (HOURS)

Up to 320 results in 8 Up to 320 results in 8 Up to 320 results in 8 Up to 320 results in 8 hrhrhrhr shiftshiftshiftshift Additional 420 run unassisted into 2Additional 420 run unassisted into 2Additional 420 run unassisted into 2Additional 420 run unassisted into 2ndndndnd shiftshiftshiftshift

First 5 results First 5 results First 5 results First 5 results released released released released

2 2 2 2 hrhrhrhr and 41 minand 41 minand 41 minand 41 min

Up to 750 tests Up to 750 tests Up to 750 tests Up to 750 tests in approx.15 in approx.15 in approx.15 in approx.15 hrhrhrhr

Page 7: PANTHER: WASTE AND CONTAMINATION MANAGEMENT · • Plasma: EDTA, ACD, PPT • Serum: SST, serum tubes Secondary Tube Sampling • Minimum of 700 μLplasma / serum required with HologicSpecimen

Limit of Detection Limit of Detection Limit of Detection Limit of Detection (LoD)(LoD)(LoD)(LoD)

Limit of Detection Limit of Detection Limit of Detection Limit of Detection (LoD)(LoD)(LoD)(LoD)

12 copies/mL

Dynamic RangeDynamic RangeDynamic RangeDynamic RangeDynamic RangeDynamic RangeDynamic RangeDynamic Range 30 – 10 million copies/mL

Intended UseIntended UseIntended UseIntended UseIntended UseIntended UseIntended UseIntended Use Monitoring / Diagnosis ‘21 Diagnosis and monitoring

Sample RequirementSample RequirementSample RequirementSample RequirementSample RequirementSample RequirementSample RequirementSample Requirement Reaction volume 0.5 mL

Primary Tube Sampling

• Minimum of 1200 μL plasma / serum

• Plasma: EDTA, ACD, PPT

• Serum: SST, serum tubes

Secondary Tube Sampling

• Minimum of 700 μL plasma / serum required with

Hologic Specimen Aliquot Tube (SAT)

• Dilution for low volume samples with

automated software calculation to neat

concentration

APTIMA HIV-1 QUANT DX ASSAY

7

Monitoring

4.8 IU/mL (Plasma)5.9 IU/mL (Serum)

10 – 9 log10 IU/mL

Reaction volume 0.5 mL

Dual target, multiple probes: pol & LTR

Aptima HIVAptima HIVAptima HIVAptima HIV----1 Quant1 Quant1 Quant1 Quant

Page 8: PANTHER: WASTE AND CONTAMINATION MANAGEMENT · • Plasma: EDTA, ACD, PPT • Serum: SST, serum tubes Secondary Tube Sampling • Minimum of 700 μLplasma / serum required with HologicSpecimen

CLINICAL PERFORMACE FROM 3RD PARTY INVESTIGATORS

Weismann et al., Journal of Clinical Microbiology (2018) Oct;56(10)

The Aptima HIV-1 assay provides consistent, trusted results for viral load monitoring with full subtype coverage

50 copies / mL 200 copies / mL

Page 9: PANTHER: WASTE AND CONTAMINATION MANAGEMENT · • Plasma: EDTA, ACD, PPT • Serum: SST, serum tubes Secondary Tube Sampling • Minimum of 700 μLplasma / serum required with HologicSpecimen

CLINICAL PERFORMACE FROM 3RD PARTY INVESTIGATORS

0 2 4 6 80

2

4

6

8

RealTime HIV log copies/mL

Aptima HIV log copies/mL N=158

R=0.98

Y = 1,071*X - 0,04817

Reproducibility

Clin

ical

Corr

elat

ion

The Aptima HIV-1 assay provides consistent, trusted results for viral load monitoring with full subtype coverage

Page 10: PANTHER: WASTE AND CONTAMINATION MANAGEMENT · • Plasma: EDTA, ACD, PPT • Serum: SST, serum tubes Secondary Tube Sampling • Minimum of 700 μLplasma / serum required with HologicSpecimen

WASTE AND CONTAMINATIONMANAGEMENT

Page 11: PANTHER: WASTE AND CONTAMINATION MANAGEMENT · • Plasma: EDTA, ACD, PPT • Serum: SST, serum tubes Secondary Tube Sampling • Minimum of 700 μLplasma / serum required with HologicSpecimen

WASTE MANAGEMENT AND CONTAMINATION

CONTROL

Deactivation Queue

Waste Deflector

Solid Waste Container

Liquid Waste Bottle

Page 12: PANTHER: WASTE AND CONTAMINATION MANAGEMENT · • Plasma: EDTA, ACD, PPT • Serum: SST, serum tubes Secondary Tube Sampling • Minimum of 700 μLplasma / serum required with HologicSpecimen

LIQUID WASTE COMPOSITION

MaterialMaterialMaterialMaterial % by volume% by volume% by volume% by volume

TCRTCRTCRTCR 12.20%

SampleSampleSampleSample 9.76%

WashWashWashWash 24.39%

OilOilOilOil 2.44%

AmpAmpAmpAmp 1.22%

EnzymeEnzymeEnzymeEnzyme 0.61%

PromotorPromotorPromotorPromotor 0.61%

DeactivationDeactivationDeactivationDeactivation 48.78%

pHpHpHpH 9

Reportable ComponentReportable ComponentReportable ComponentReportable Component::::MgCl, KCl, Trizma HCl, Trizma Base, Zinc Acetate, Glycerol

Reportable ComponentReportable ComponentReportable ComponentReportable Component::::Triton X, EDTA, Trelahose, HEPES, N-Acetyl-L-Cysteine, KCl, Glycerol

Reportable ComponentReportable ComponentReportable ComponentReportable Component::::Lithium Hydroxide, HEPES, Lauryl Sulfate, Succinic Acid

Reportable ComponentReportable ComponentReportable ComponentReportable Component::::NaOH, Sodium Hypochlorite, Sodium Bicarbonate

Reportable ComponentReportable ComponentReportable ComponentReportable Component::::NaOH, Lauryl Sulfate Sodium, EDTA

Reportable ComponentReportable ComponentReportable ComponentReportable Component::::Polydimethylsiloxane

Page 13: PANTHER: WASTE AND CONTAMINATION MANAGEMENT · • Plasma: EDTA, ACD, PPT • Serum: SST, serum tubes Secondary Tube Sampling • Minimum of 700 μLplasma / serum required with HologicSpecimen

DEACTIVATION OF REACTIONS

• BleachBleachBleachBleach

• Denatures nucleic acid

• Effective at low concentrations

• Universally employed as disinfectant

• Guanidinium thiocyanate (GTC)Guanidinium thiocyanate (GTC)Guanidinium thiocyanate (GTC)Guanidinium thiocyanate (GTC)

• Used as a general protein denaturant

• Toxic reagent; requires Hazardous Waste Management

• Traditional method for reaction inactivation

Page 14: PANTHER: WASTE AND CONTAMINATION MANAGEMENT · • Plasma: EDTA, ACD, PPT • Serum: SST, serum tubes Secondary Tube Sampling • Minimum of 700 μLplasma / serum required with HologicSpecimen