Controlmatik abw M5262 - 10/04
DOSING MEASUREMENT &
REGULATION EQUIPMENT
Product information
Compact swimmingpool
measurment & regulation
unit seriesM 5262 C
General:
Compact swiimingpool measurment & regulation unit type M 5262 C is designed for
measurment and control of free chlorine, redox and pH in swimming-pools applications.
The unit consists of two electrodes (gold and copper - measurement electrodes) measure-
ment cell with mechanical cleaning and flow armature with pH and redox electrode and with three
microprocessor controlled display units with with PID regulator build in and with automatictemperature compensation which provides accurate measured signal on the output and is
shown on the graphical display.
Each control unit is equipped with PID regulator output and with two galvanically separated4-20 mA signal on the amplifiers output. Unit can control dosing pumps or motor dosing valve
User can easily communicate with control unit over graphic display and four keys.
All this guarantees accurate and continuous measurement and regulation.
on-line free chlorine, pH and redox measurement
PID regulation for free chlorine and pH included
galvanicaly separated current outputs
digital outputs for dosing pumps or motor valve reg.
Measuring and control
-
7/30/2019 new_M5262C_1
2/2
Order codes :
M 5262C/
Contro lmatik abw M5262 - 10/04
Fajfarjeva 15, 1230 Domzale, SlovenijaTel. +386 1 72 13 552, Fax + 386 1 72 19 360
E-mail: [email protected]
Measuring ranges
Cl - 0-1 mgCl2/l
pH - 2-12 pH
Redox - 0 - 1000 mV
DOSING MEASUREMENT &
REGULATION EQUIPMENT
C - Current output sensor (4 - 20 mA)
D - Communication output - Selecan
SCH00040
185
Electronics unit drawing:
A - Automatic temperature
compensation
Units drawing:
Data is subject to change without notice.
Measuring and control
Technical data :
Measuring range (M.R.) 0 - 1 mg/l, 2 -12 pH, 0 -1000 mV
Measured value resolution 0,01 mg/l, 0,1pH, 1 mV
Deviation of indication, measured value maximum 2% of M.R.
pH range 6.5...8,5
Automatic temperature compensation range 0...+50C
Electrical data :
Supply voltage 24 VAC20%
Power 3 x 5 W Maximum
Isolation voltage 500V (to analog part)
Current output connector (each electronic):
Moduls 2
Current range 4...20 mA
Load maximum 600 E
Output range adjustable to (M.R.)
Output Mode Selectable
- Free chlorine output, pH output, redox output
- Temperature
- Regulator output
Regulator connector (each electronic):
Outputs 2 x 24 VAC / 250 mAInputs 2 x 24 VAC
Mode Selectable
- Motor Control
- Pump Control
General data :
Ambient temperature -10...+50C
Relative humidity 10...95 % non-condensating
Control unit protection IP 65
Dimensions 300 x 450 x 70
Weight 5,0 kg
R - Regulator included