Metrotomography University Uppsala OPT [Kompatibilitetsläge]

40
Metrotomography A tool for optimization of business processes 10.11.2010 10.11.2010 R lfB i Ralf Benninger Product Manager

Transcript of Metrotomography University Uppsala OPT [Kompatibilitetsläge]

Page 1: Metrotomography University Uppsala OPT [Kompatibilitetsläge]

Metrotomography

A tool for optimization of business processesp

10.11.201010.11.2010

R lf B iRalf BenningerProduct Manager

Page 2: Metrotomography University Uppsala OPT [Kompatibilitetsläge]

Agenda

1 Who is Carl Zeiss1

2

3

What means Metrotomography

Accuracy

Who is Carl Zeiss

3

4

5

Accuracy

Industrial application

Summary

13.12.2010 2Carl Zeiss IMT GmbH, Ralf Benninger, IP-L

Page 3: Metrotomography University Uppsala OPT [Kompatibilitetsläge]

Agenda

1 Who is Carl Zeiss1

2

3

What means Metrotomography

Accuracy

Who is Carl Zeiss

3

4

5

Accuracy

Industrial application

Summary

13.12.2010 3Carl Zeiss IMT GmbH, Ralf Benninger, IP-L

Page 4: Metrotomography University Uppsala OPT [Kompatibilitetsläge]

Carl Zeiss Group

Carl Zeiss AG

s G

roup

s

Medical Systems Microscopy Semiconductor Technology

Industrial Metrology

Consumer Optics/Optronics Carl Zeiss Vision

Carl Zeiss AG

Busi

ness

Mar

kets Medical and Research

SolutionsLifestyle ProductsIndustrial Solutions Vision

Care

Employees worldwide approx. 24,000

13.12.2010 4Carl Zeiss IMT GmbH, Ralf Benninger, IP-L

Page 5: Metrotomography University Uppsala OPT [Kompatibilitetsläge]

Carl Zeiss Industrial Metrology

Coordinate Measurement Machines, Sensors, Software

13.12.2010 5Carl Zeiss IMT GmbH, Ralf Benninger, IP-L

Page 6: Metrotomography University Uppsala OPT [Kompatibilitetsläge]

Agenda

1 Who is Carl Zeiss1

2

3

What means Metrotomography

Accuracy

Who is Carl Zeiss

3

4

5

Accuracy

Industrial application

Summary

13.12.2010 6Carl Zeiss IMT GmbH, Ralf Benninger, IP-L

Page 7: Metrotomography University Uppsala OPT [Kompatibilitetsläge]

The METROTOM® - Family

METROTOM® 800 METROTOM® 1500

13.12.2010 7Carl Zeiss IMT GmbH, Ralf Benninger, IP-L

Page 8: Metrotomography University Uppsala OPT [Kompatibilitetsläge]

Technology

13.12.2010 8Carl Zeiss IMT GmbH, Ralf Benninger, IP-L

Page 9: Metrotomography University Uppsala OPT [Kompatibilitetsläge]

Typical applications

3D-Volume

data

Reverse Engineering

CAD-Comparison

Defectanalysis

Dimensional Metrology

3D CAD3D CAD

13.12.2010 9Carl Zeiss IMT GmbH, Ralf Benninger, IP-L

Page 10: Metrotomography University Uppsala OPT [Kompatibilitetsläge]

Agenda

1 Who is Carl Zeiss1

2

3

What means Metrotomography

Accuracy

Who is Carl Zeiss

3

4

5

Accuracy

Industrial application

Summary

13.12.2010 10Carl Zeiss IMT GmbH, Ralf Benninger, IP-L

Page 11: Metrotomography University Uppsala OPT [Kompatibilitetsläge]

Customer‘s Question

„How accurate are o r res lts?“

Focus Spot Size your results?“?

Voxel Size

Detector Resolution

Level of Details

Resolution of Scales Sub-

voxelling

13.12.2010 11Carl Zeiss IMT GmbH, Ralf Benninger, IP-L

Page 12: Metrotomography University Uppsala OPT [Kompatibilitetsläge]

Measurement Uncertainty

Tolerance

N i lNominal Value

Measurement Uncertainty

13.12.2010 12Carl Zeiss IMT GmbH, Ralf Benninger, IP-L

y

Page 13: Metrotomography University Uppsala OPT [Kompatibilitetsläge]

Measurement Performance

13.12.2010 13Carl Zeiss IMT GmbH, Ralf Benninger, IP-L

Accuracy is depending mainly on right calibration of the projection geometry!

Page 14: Metrotomography University Uppsala OPT [Kompatibilitetsläge]

Geometrical distortion

Axis calibration

Geometric calibration

Detector calibration

Wire phantom Geometry phantom

13.12.2010 14Carl Zeiss IMT GmbH, Ralf Benninger, IP-L

Page 15: Metrotomography University Uppsala OPT [Kompatibilitetsläge]

Edge localizationEdge localization

Step cylinder with one h t i lhomogeny material

Beam HardeningDifferent lengths cause different grey valuesdifferent grey values.

ISO 50 thresholdISO 50 threshold

Global threshold cause high deviations in surface extraction

(40 µm error)(40 µm error)

D namic thresholdDynamic threshold

High accuracy demands an efficient method for local surface detection.

13.12.2010 15Carl Zeiss IMT GmbH, Ralf Benninger, IP-L

high subvoxel accuracy!

(5 µm error)

Page 16: Metrotomography University Uppsala OPT [Kompatibilitetsläge]

Specification of Accuracy according to VDI/VDE 2630

There are VDI/VDE Standards now, the draft has already been published (July 2009)

Gages for acceptance of CMMs with CT-Sensor according to VDI/VDE 2630:

MetrotomCheck Step Cylinder

13.12.2010 16Carl Zeiss IMT GmbH, Ralf Benninger, IP-L16

Page 17: Metrotomography University Uppsala OPT [Kompatibilitetsläge]

High Number of Acceptance Tests

13.12.2010 17Carl Zeiss IMT GmbH, Ralf Benninger, IP-L

Page 18: Metrotomography University Uppsala OPT [Kompatibilitetsläge]

METROTOM Customers

RWTH Aachen,

d !

Uni Kosice (SK),

Teknologisk Institut (DK)

13.12.2010 18Carl Zeiss IMT GmbH, Ralf Benninger, IP-L

… and many more!

Page 19: Metrotomography University Uppsala OPT [Kompatibilitetsläge]

Agenda

1 Who is Carl Zeiss1

2

3

What means Metrotomography

Accuracy

Who is Carl Zeiss

3

4

5

Accuracy

Industrial application

Summary

13.12.2010 19Carl Zeiss IMT GmbH, Ralf Benninger, IP-L

Page 20: Metrotomography University Uppsala OPT [Kompatibilitetsläge]

Metrology of Carl Zeiss supports the injection molding industryg y

Mold First part A bl ProductionVerificationMold development process

First part inspection report

Assembly control

Production process control

Verification of process parameter

13.12.2010 20Carl Zeiss IMT GmbH, Ralf Benninger, IP-L

Page 21: Metrotomography University Uppsala OPT [Kompatibilitetsläge]

Example: very complex case of a plug connector

More than 500 inspection characteristic!

13.12.2010 21Carl Zeiss IMT GmbH, Ralf Benninger, IP-L

Page 22: Metrotomography University Uppsala OPT [Kompatibilitetsläge]

Previous method

Because of the high accuracy requirements it is important to measure several hundreds of features.

To reach all features the plug connector has to be sliced into pieces For a first partTo reach all features the plug connector has to be sliced into pieces. For a first partinspection report of a 4 cavity casting mold the user has to calculate with 4 weeks work.

With the help of Metrotomographyit is possible to save more than3 weeks time.

Furthermore the parts have notFurthermore the parts have notto be destroyed.

13.12.2010 22Carl Zeiss IMT GmbH, Ralf Benninger, IP-L

Page 23: Metrotomography University Uppsala OPT [Kompatibilitetsläge]

Non-destructive measuring

Example:Example:

Complete inspection of a plastic plug connector consisting of threeconsisting of three different materials.

13.12.2010 23Carl Zeiss IMT GmbH, Ralf Benninger, IP-L

Page 24: Metrotomography University Uppsala OPT [Kompatibilitetsläge]

What can be measured?

All kind of features and elements, tolerances (shape tolerances (shape and location), ….

PTB-certified

Software!

13.12.2010 24Carl Zeiss IMT GmbH, Ralf Benninger, IP-L 24

Page 25: Metrotomography University Uppsala OPT [Kompatibilitetsläge]

Inspection reports

Metrological evaluation Metrological evaluation with CalypsoThe technology is new, theevaluation environment is thesame as before. As with tactilesame as before. As with tactilemeasurements, the evaluation ismade in Calypso.

From data import of the CADmodel up to the CNC run youcan work with your familiarevaluation tools.

VDA First part inspection report Presentation protocol

13.12.2010 25Carl Zeiss IMT GmbH, Ralf Benninger, IP-L 25

VDA First part inspection report Presentation protocol

Page 26: Metrotomography University Uppsala OPT [Kompatibilitetsläge]

Graphic inspection reports

Metrological evaluation Metrological evaluation with CalypsoThe technology is new, theevaluation environment is thesame as before. As with tactilesame as before. As with tactilemeasurements, the evaluation ismade in Calypso.

From data import of the CADmodel up to the CNC run youcan work with your familiarevaluation tools.

Flatness plot Graphic protocol

13.12.2010 26Carl Zeiss IMT GmbH, Ralf Benninger, IP-L

Flatness plot Graphic protocol

Page 27: Metrotomography University Uppsala OPT [Kompatibilitetsläge]

Mold correction -Process requirementsq

The dimensions of a part needs to be in predefined tolerancesThe part should be complete filled with medium.

In practice for complex plastic parts mostly there are multiple iteration cycle needed to getIn practice for complex plastic parts mostly there are multiple iteration cycle needed to get the final mold.Correction data's has to be determined and integrated into the Mold CAD-design

Form Correction datadata

BauteilPart

13.12.2010 27Carl Zeiss IMT GmbH, Ralf Benninger, IP-L

Page 28: Metrotomography University Uppsala OPT [Kompatibilitetsläge]

An injection mold development process

CAD 3D NominalNominal

Injection process

CAD mold 3D nominal Mold making Molded part Deviation of

size, shape and position First part

Mold manufacturing

position pinspection reportMold

measurement

Measurement report

M ld CAD mold actual

13.12.2010 28Carl Zeiss IMT GmbH, Ralf Benninger, IP-L

Mold correction

CAD mold actual + correction

Multiple Iteration cycle!

Page 29: Metrotomography University Uppsala OPT [Kompatibilitetsläge]

Optimized injection mold development processp

CAD 3D NominalNominal

Injection process

CAD mold 3D nominal Mold

makingMolded part Deviation of

size, shape and position First part

Mold manufacturing

position pinspection reportMold

measurement

C ti l

M ld CAD 3D mold Calypso mold

Required correction points

Correction values

13.12.2010 29Carl Zeiss IMT GmbH, Ralf Benninger, IP-L

Mold correction

CAD 3D mold actual +

correction

ypcorrection

30-70% saving of time

Page 30: Metrotomography University Uppsala OPT [Kompatibilitetsläge]

Defect Analysis

NDT technology Defect analysis is often usedfor the first check of the

tcomponent.

13.12.2010 30Carl Zeiss IMT GmbH, Ralf Benninger, IP-L

Page 31: Metrotomography University Uppsala OPT [Kompatibilitetsläge]

Quantitative und Qualitative Porosity Analysis

axial frontal

The Porosity Analysis helps to find defects and to optimize process parameter

13.12.2010 31Carl Zeiss IMT GmbH, Ralf Benninger, IP-L

The Porosity Analysis helps to find defects and to optimize process parameter

If the product process is solid there is always the same shrinking hole picture

Page 32: Metrotomography University Uppsala OPT [Kompatibilitetsläge]

Assembly Control

Assembly Control takes place at different stations in the value chain.It can be measured non-destructively.

DevelopmentDevelopmentDo all party fit together, clearances, …?Are the breeches consolidated, do the O-Ring sit right?

ProductionAre all components installed?Do all components sit like required?

Quality assuranceEnvironmental checks, temperature cycle, vibrations checks, drop tests,…Geometry modification before and after use

Complaint managementNon-destructive analysis of the components

13.12.2010 32Carl Zeiss IMT GmbH, Ralf Benninger, IP-L

Page 33: Metrotomography University Uppsala OPT [Kompatibilitetsläge]

Assembly control of a insulin pen

13.12.2010 33Carl Zeiss IMT GmbH, Ralf Benninger, IP-L

Page 34: Metrotomography University Uppsala OPT [Kompatibilitetsläge]

Assembly control of a insulin pen

13.12.2010 34Carl Zeiss IMT GmbH, Ralf Benninger, IP-L

Page 35: Metrotomography University Uppsala OPT [Kompatibilitetsläge]

Assembly control of a insulin pen

13.12.2010 35Carl Zeiss IMT GmbH, Ralf Benninger, IP-L

Page 36: Metrotomography University Uppsala OPT [Kompatibilitetsläge]

Assembly control of a insulin pen

13.12.2010 36Carl Zeiss IMT GmbH, Ralf Benninger, IP-L

Page 37: Metrotomography University Uppsala OPT [Kompatibilitetsläge]

Assembly control of a insulin pen

13.12.2010 37Carl Zeiss IMT GmbH, Ralf Benninger, IP-L

Page 38: Metrotomography University Uppsala OPT [Kompatibilitetsläge]

Agenda

1 Who is Carl Zeiss1

2

3

What means Metrotomography

Accuracy

Who is Carl Zeiss

3

4

5

Accuracy

Industrial application

Summary

13.12.2010 38Carl Zeiss IMT GmbH, Ralf Benninger, IP-L

Page 39: Metrotomography University Uppsala OPT [Kompatibilitetsläge]

Summary

Metrotomography is the fusion of metrology and tomography.

Accuracy is depending mainly on right calibration of the projection geometryAccuracy is depending mainly on right calibration of the projection geometry

The Metrotomography supports important processes in the injection molding industry

First part inspection reports in shorter time

Decrease the number of iteration cycle in the mold development process

Non-destructive assembly control

13.12.2010 39Carl Zeiss IMT GmbH, Ralf Benninger, IP-L

Page 40: Metrotomography University Uppsala OPT [Kompatibilitetsläge]

13.12.2010 40Carl Zeiss IMT GmbH, Ralf Benninger, IP-L