Mark Vagins Kavli IPMU/UC Irvine

30
Mark Vagins Kavli IPMU/UC Irvine AAP2012, Manoa October 4, 2012 GADZOOKS! Status: Making World-class Water

description

GADZOOKS! Status: Making World-class Water. Mark Vagins Kavli IPMU/UC Irvine. AAP2012, Manoa October 4, 2012. גדוליניום. “Gadol” = Great. !. Theorist John Beacom and I wrote the original GADZOOKS! ( G adolinium A ntineutrino D etector Z ealously - PowerPoint PPT Presentation

Transcript of Mark Vagins Kavli IPMU/UC Irvine

Page 1: Mark Vagins Kavli IPMU/UC Irvine

Mark VaginsKavli IPMU/UC IrvineAAP2012, ManoaOctober 4, 2012

GADZOOKS! Status:Making World-class Water

Page 2: Mark Vagins Kavli IPMU/UC Irvine

Theorist John Beacom and I wrote the original GADZOOKS! (Gadolinium Antineutrino Detector Zealously

Outperforming Old Kamiokande, Super!) paper in 2003.

It proposed loading big WC detectors, specifically Super-K, with water soluble gadolinium, and evaluated the physics potential and backgrounds of a giant antineutrino detector. [Beacom and Vagins, Phys. Rev. Lett., 93:171101, 2004]

גדוליניום

“Gadol” = Great!

Page 3: Mark Vagins Kavli IPMU/UC Irvine

e can be identified by delayed coincidence.

e

e+

2.2 MeV -rayp

nPossibility 1: 10% or less

n+Gd →~8MeV T = ~30 sec

Possibility 2: 90% or more

Positron and gamma ray vertices are within ~50cm.

n+p→d +

p

Gd

Basically, we said, “Let’s add 0.2% of a water soluble gadolinium compound to Super-K!”

Page 4: Mark Vagins Kavli IPMU/UC Irvine

Here’s what the coincident signals in Super-K with GdCl3 or Gd2(SO4)3 will look like

(energy resolution is applied):

Most modernDSNB range

e + p e+ + n spatial and

temporal separation between prompt e+

Cherenkov light and delayed Gd neutron

capture gamma cascade:

=~4cm, =~30s A few clean events/yr

in Super-K with Gd

Page 5: Mark Vagins Kavli IPMU/UC Irvine

In a nutshell: adding 100 tons of soluble Gd to Super-K would provide at least two brand-new signals:

1) Discovery of the diffuse supernova neutrino background [DSNB],

also known as the “relic” supernova neutrinos

(up to 5 events per year)

2) Precision measurements of the neutrinos from all of

Japan’s power reactors(thousand[s of] events per year)

Will improve world average precision of m2

12

Page 6: Mark Vagins Kavli IPMU/UC Irvine

Now, Beacom and I never wanted to merely propose a new technique – we wanted to make it work!

Suggesting a major modification of one of the world’s leading neutrino detectors may not be

the easiest route…

[Snowbird photo by A. Kusenko]

Page 7: Mark Vagins Kavli IPMU/UC Irvine

…and so to avoid wiping out, some careful hardware studies are needed.

• What does gadolinium do the Super-K tank materials?• Will the resulting water transparency be acceptable?• Any strange Gd chemistry we need to know about?• How will we filter the SK water but retain dissolved Gd?

Page 8: Mark Vagins Kavli IPMU/UC Irvine

Over the last eight years there have been a large number ofGd-related R&D studies carried out in the US and Japan:

Page 9: Mark Vagins Kavli IPMU/UC Irvine

The Essential Magic Trick→ We must keep the water in any Gd-loaded detector perfectly clean… without removing the dissolved Gd.

→ I’ve developed a new technology: “Molecular Band-Pass Filtration” Staged nanofiltration selectively retains Gd while removing impurities.

Amazingly, the darn thing works!

This technology will support a variety of applications, such as:

→ Supernova neutrino and proton decay searches

→ Remote detection of clandestine fissile material production

→ Efficient generation of clean drinking water without electricity

Page 10: Mark Vagins Kavli IPMU/UC Irvine

Electrical Band-Pass Filter

Page 11: Mark Vagins Kavli IPMU/UC Irvine

Molecular Band-Pass Filter

Ultrafilter Nanofilter

Reverse Osmosis

Larger and smallerimpurities to drain

(UF Flush + RO Reject)

Pure water (RO product) plus Gd2(SO4)3

Pure waterplus Gd2(SO4)3

Gd2(SO4)3 (NF Reject)

Gd2(SO4)3 plus smaller impurities (UF Product)

Impurities smaller than Gd2(SO4)3 (NF Product)

Impurities larger than Gd2(SO4)3 (UF Reject

flushed periodically )

Page 12: Mark Vagins Kavli IPMU/UC Irvine

NFReject

UFProduct

Page 13: Mark Vagins Kavli IPMU/UC Irvine

Band PassWindow

Page 14: Mark Vagins Kavli IPMU/UC Irvine

Prototype Selective Filtration Setup @ UCI

UltrafilterNanofilter #2 Reverse Osmosis

Nanofilter #1

MembranePre-Flush

Page 15: Mark Vagins Kavli IPMU/UC Irvine

Ultrafilter Nanofilter #1

RO #1 Impurities to drain

(UF Flush) Pure water (RO product) plus Gd2(SO4)3 back to tank

waterplus Gd2(SO4)3 from maintank

Gd2(SO4)3 (NF#1 Reject)

Gd2(SO4)3 plus smaller impurities (UF Product)

Impurities larger than Gd2(SO4)3

trapped in UF (UF Reject

flushed periodically )

Nanofilter #2DI

August 2009 “Band-pass Filter”

RO Reject to small tank

RejectTank DI RO #2

Gd2(SO4)3 (NF#2 Reject)

TOC

Page 16: Mark Vagins Kavli IPMU/UC Irvine

Ultrafilter Nanofilter #1

RO #1 Impurities to drain

(UF Flush) Pure water (RO product) plus Gd2(SO4)3 back to tank

waterplus Gd2(SO4)3 from maintank

Gd2(SO4)3 (NF#1 Reject)

Gd2(SO4)3 plus smaller impurities (UF Product)

Impurities larger than Gd2(SO4)3

trapped in UF (UF Reject

flushed periodically )

Nanofilter #2DI

August 2009 “Band-pass Filter”

RO Reject to small tank

RejectTank DI RO #2

Gd2(SO4)3 (NF#2 Reject)

TOC

This design works well. It is the world’s first operational selective filtration system.

Water quality is indefinitelymaintained/improved,

with or without gadolinium.

There is <60 ppb loss of Gd per cycle.

However, the prototype system at UCI processes just 0.2 tons of water per hour.

It must be industrialized tobe of use in SK…

Page 17: Mark Vagins Kavli IPMU/UC Irvine

A dedicated Gd test facility has been built in the Kamioka mine, complete with its own water filtration system, 50-cm PMT’s,

and DAQ electronics.

This 200 ton-scale R&D project is called EGADS – Evaluating Gadolinium’s Action on Detector Systems.

Super-K Water system

50m

EGADS Hall(2500 m^3)

Super-Kamiokande

Page 18: Mark Vagins Kavli IPMU/UC Irvine

200 ton (6.5 m X 6.5 m)water tank (SUS304)

240 50-cm PMT’s

Selective Water+Gd Filtration System Transparency

Measurement

EGADS Facility

[graphic byA. Kibayashi]

In June of 2009 we receivedfull funding

(~$4,300,000)for this effort.

Gd Pretreatment System

Page 19: Mark Vagins Kavli IPMU/UC Irvine

EGADS Cavern as of December 14, 2009

6.5 meters

Page 20: Mark Vagins Kavli IPMU/UC Irvine

EGADS Cavern as of February 27, 2010

Page 21: Mark Vagins Kavli IPMU/UC Irvine

EGADS Cavern as of April 16, 2010

Page 22: Mark Vagins Kavli IPMU/UC Irvine

EGADS Cavern as of April 28, 2010

Page 23: Mark Vagins Kavli IPMU/UC Irvine

EGADS Cavern as of June 8, 2010

Page 24: Mark Vagins Kavli IPMU/UC Irvine

EGADS Cavern as of December 10, 2010

Page 25: Mark Vagins Kavli IPMU/UC Irvine

Just another Thanksgiving weekend; Nov. 25th, 2011

Page 26: Mark Vagins Kavli IPMU/UC Irvine

;.

11/2011 200-ton WaterCherenkov Detector (240 50-cm PMT’s)

Selective Water+Gd Filtration System

15-ton GadoliniumPre-treatment Mixing Tank

Page 27: Mark Vagins Kavli IPMU/UC Irvine

Cherenkov Light Remaining at 20 m (200-ton tank)

Within a few months of turning on the system our pure

“band-pass” water was as good as Super-K's ultrapure water after

15 years of tuning and adjustments!

We then introduced gadolinium into the system…

Page 28: Mark Vagins Kavli IPMU/UC Irvine

Stable running

~66% light @ 1900 ppmwith Amberjet4400,

~63% without

Studies continue, but we have already achieved

stable light levels of 66% at 20 meters with fully

Gd-loaded water.

This should be compared to a range of 71%79% for “perfect”

pure water in SK-IV.

No detected Gd loss after >100 complete

turnovers.

Page 29: Mark Vagins Kavli IPMU/UC Irvine

29

Newly funded: Multi-messenger Supernova AstronomyX-ray, -ray,

Optical, Infrared,GW, andNeutrino

Approved - June 2012~$1.6M for EGADS/IPMU

Page 30: Mark Vagins Kavli IPMU/UC Irvine

By 2015 we expect to be ready to detect supernova neutrinos with EGADS from anywhere in our galaxy,

and produce immediate alerts to the world. No politics!

By 2016 it is likely we will be adding Gd to Super-K.