INTRUDER ALARMS

020 7622 5151www.banham.co.ukor visit

Page 2: INTRUDER ALARMS - Banham · PDF fileto false alarms. Grade 2 Class 2. H123 x W72 x D57 Detection area 12m x 12m ... a wireless portable panic button and wireless external self actuating

INTRUDER ALARM CONTROL EQUIPMENT

8 alarm point expansion modules incorporating a local psu.

CAC Door access control unit which fully integrates with the Xpander range of intruder control equipment. This facility provides the following options:• Connection for either internal or external readers.• Lock release facility which will accommodate most

scenarios ranging between 12v, 24 DC through to AC mechanisms.

• Key/Card fob control which is compatible with the intruder alarm system.

• Lock open timer between 0-250 seconds.• Door open timer between 0-250 seconds.• Local alarm output facility for audible warning.• Request to exit button.• On board 2.5 amp power supply facility. Grade 2 Class 2. H390 x W305 x D100

PSU/ZEM2 channel remote receiver used in conjunction with the Banham double push remote panic button transmitter. Grade 2/3 Class 2.H103 x W317 x D32

RX2External quality card/TAG reader with 2m of connection screened cable manufactured to IP66 Standard.Grade 2 Class 4.H85 x W85 x D20

ETR

1 amp power supply unithoused in a metal box to provideadditional auxiliary current, withinternal mains and battery faultindicator lamps. Grade 2/3 Class 2.H388 x W240 x D86

PS11·4 amp power supply unithoused in a metal box to provideadditional auxiliary current, withinternal mains and battery faultindicator lamps. Grade 2/3 Class 2.H335 x W363 x D90

PS1-4

Device for setting and unsetting a defined area with onboard fault indicator lights.Grade 2/3 Class 2.H100 x W40 x D24

SURDouble push portable remote panic button.Grade 2 Class 2.range approx 100msubject to environment.H166 x W46 x D30

RPBB28 wireless alarm point expansion module suitable for connecting to the G76 xpander range and above. Images of detector equipment overleaf.

ANNO HYBRID ZEM8/2 alarm point expansion module incorporating 4/1 programmable outputs. Grade 2/3 Class 2.H173 x W126 x D31

ZEM/TMZ

Control Panel Code G24 Grade 2 Class 2

G76 Grade 3 Class 2

G280 Grade 3 Class 2

Alarm Points (In Panel) 8 8 8

Max Number of Alarm Points (Fully Expanded) 24 76 280

Remote Keypads/TMZ Modules 4 9 16Alarm Point Expansion Modules (Wireless/Wired) 1 7 36

Downline Diagnostic/Maintenance Facility yes yes yes

Full Proximity/Tag/Keyswitch or Shunt Lock Setting yes yes yes

Individual Tag Users 15 100 500

Number of Door Access Controls 3 5 15

Programmable Part/Night Sets 3 7 14

Independent Area Sets 4 8 14

Event Log Memory (events) 500 2000 2500

On Board Programmable Outputs yes yes yes

On Board Power Supply 1.5 amp 2.5 amp 2.5 amp

Tag Readers in Place of Remote Keypads 3 15 15

Full Standby Battery Backup yes yes yes

*Wireless Alarm Point Expansion Modules 1 2 4Panel dimensions: G24: H297 x W250 x D82 G76/G280: H390 x W305 x D100

* = Anno Hybrid Point Expansion Modules

Banham Range of Control Equipment(with Downline Diagnostic Facility)

Standard Xpander rangekeypad (surface mounted) incorporating full English text on a 16 character LCD providing full proximity keyfob/card operation. Grade 2/3 Class 2.H100 x W145 x D35

C22KFlush or surface mounted toughened plastic Xpander range keypad incorporating full English text on a 16 character LCD providing full proximity keyfob/card operation. Available in either polished/satin, brass or chrome/ black/pearl white/copper.Grade 2/3 Class 2.H160 x W126 x D30

M22KKeyfob designed to be placed on a keyring and be programmed to enable operation of an intruder alarm keypad (3 supplied per system).Grade 2/3 Class 2. H45 x W30 x D2

E.TAG

This is flush fitting which allows the device to be mounted in a standard UK gang box, thanks to its flat face and recessed buttons. Grade 3 compliant.H85 x W85 x D1

EPA/STD SS

Page 3: INTRUDER ALARMS - Banham · PDF fileto false alarms. Grade 2 Class 2. H123 x W72 x D57 Detection area 12m x 12m ... a wireless portable panic button and wireless external self actuating

Commercial quality PIR detector with super quad logic and anti-masking technology.Grade 3 Class 2.H115 x W70 x D52.3 Detection area 15m x 15m

BAN CXPIRCombined PIR & PIR microwave detector with anti mask facility. This unit can provide a sequential confirmed signal.Grade 3 Class 2.12m x 12m (detection pattern)H180 x W75 x D40Detection area 15m x 13m

BAN TMDCeiling mounted intruder detector that features both omni-directional quad element PIR and K-band microwave sensing.Grade 2 Class 2.

BAN 36ODT

Mounting height: max 3.6m x 9.3m dia

Dual technology detector integrating PIR and ultrasonic detection coverage to provide a greater degree of immunity to false alarms. Grade 2 Class 2.H123 x W72 x D57 Detection area 12m x 12m

BAN P9DT

Dual technology detector incorporating both PIR and microwave technology and anti mask technology. This device is suitable for particularly harsh environments and allows the microwave technology to be isolated when unset. Grade 3 Class 2. H128 x W65 x D45 15m x 85 deg

BAN 815DTDual technology break glass detector.Grade 3 Class 2.H98 x W62 x D21.8

BAN FLEXGUARDExternal quality infra red detector that provides a multi layered horizontal barrier that projects either side of the device(12 metres per side). Grade 2 Class 4.H232.7 x W55 x D68.7

BAN BX80

Intelligent PIR detector with quad logic.Grade 2 Class 2.H112 x W66 x D46Detection area 15m x 15m

BAN T2PIR

Flush magnetic reed contact.Grade 2/3 Class 2.20mm dia x 25mm dia flush x D1

FC

Seismic vibration detector.Grade 3 Class 2.Range: 2mH85 x W23 x D26

VIBRATION SENSORAcoustic sensor with dual technology.Grade 2 Class 2.Range: 2mH33 x W100 x D24

SHATTERSWITCHSurface magnetic reed contact. Grade 2/3 Class 2.L60 x W14 x D14

SC

Ionisation/Optical low profile smoke detector.100 dia x D55

SM

Static double push panic button (surface mounted) available in brass, stainless steel or white.Grade 2/3 Class 2.H83 x W65 x D30

PANIC BUTTON

Fixed temperature heat detector above 60º C. 100 dia x D55

TPRate of rise heat detector rapid increase in temperature. 100 dia x D55

HT

DETECTION EQUIPMENT

WARNING EQUIPMENT

Mini intra integrated strobe and self actuating siren device enclosed in a polycarbonate housing with a strobe lens including standby battery.Grade 2/3 Class 4.(115 dB at 1m) H176.5 x W112.5 xD44.9

ISASSELF-ACTUATING SIREN

On-board fire sounder designed to be mounted on to a fire detector.(86 dB at 1m) dia 106 x D25

FIRE SOUNDER

16 ohm internal sounder device.Grade 2/3 Class 2/3.(12w) H110 x W110 x D58

ER

105 dB at 1m internalwarning device.Grade 2 Class 2.H55 x W107 x D32

ISIRShield shaped self-actuating siren unit with a polycarbonate translucent cover incorporating a high powered strobe unit and twin pulsing red comfort LED’s including standby battery. Option of white or black covers.Grade 2/3 Class 4. (120dB at 1m) H285 x W295 x D65

DUALTEC - Combines passive infra red and microwave technologies, which measure temperature change along with movement.

NOTE: Please contact your security design consultant for further information if required. All measurements in mm unless otherwise stated.

PIR - Passive infra red technology, which measures temperature change.

Sequential confirmation detector with quad logic utilising two independent detection alarm points which combined provide a detection coverage area of 12m x 12m or 18m x 18m.Grade 2 Class 2.H125 x W72 x D44.5Detection area 12m x 15m

BAN SQPIRAdvanced acoustic sensor with pattern recognition technology.Grade 2 Class 2.H100 x W56 x D20

SHATTERPROHeavy duty magnetic reed contact. Grade 2/3 Class 2.L44 x W34 x D10

HC

Dual technology detector integrating a PIR detector with quad zone logic and microwave technology which combine to provide a greater degree of immunity to false alarms.Grade 2 Class 2.H125 x W70 x D48.6Detection area 12m x 12m

BAN D115BAN T1PIRStandard PIR detector with quad logic.Grade 2 Class 2.H97 x W62 x D44Detection area 12m x 12m

Twin beam infra redphotoelectric beam.H167 x W67 x D66.5100m internal 40m external

AX130T

Infra red photoelectric beam (surface). H196 x W78 x D83Flush version. H114 x W70 x D30 Range: 60m internal 30m external

AX100S

Page 4: INTRUDER ALARMS - Banham · PDF fileto false alarms. Grade 2 Class 2. H123 x W72 x D57 Detection area 12m x 12m ... a wireless portable panic button and wireless external self actuating

ANNO 85 WIRELESS & HYBRID (WIRELESS & WIRED) INTRUDER ALARM SYSTEMS

If you are concerned about the detrimental effect a hard-wired security alarm could have on the aesthetics of your property then our wireless burglar alarm could provide the ideal solution. It also allows for additional alarms to be added to out-buildings such as garages and sheds.

For those looking for a wireless alarm system, our wireless range provides a number of advantages, including a wireless portable panic button and wireless external self actuating siren.

We can supply shock sensors, movement detectors and even acoustic detectors to provide a complete security package. We can also implement an individual key fob system to improve the level of access control you have over your property.

For clients who have existing systems that need to be taken over, we can also provide a hybrid solution of wired and wireless equipment.

All of our security alarm systems can be designed with your specific requirements in mind, while we will also liaise with your insurers to ensure you comply with their expectations. We also put particular emphasis on meeting the current NPCC and European Standards, and the quality of our service has been recognised with the Metropolitan Gold Award for Alarm Performance & by the NSI.

Control Panel with Built-In SounderPanel Dimensions: H160 mm x W220 mm x D55mm

MC1/Shock-WE 2 Way Wireless Magnetic Contact and Shock Sensor

H115 mm x W30 mm x D35mm (wireless)

Wireless Shock Sensor

H115 mm x W30 mm x D35mm (wireless)

Wireless Optical Smoke Detector with Built-In Sounder

120mm Dia x D53mm (wireless)

Wireless Optical Carbon Monoxide Detector with Built-In Sounder

120mm Dia x D53mm (wireless)

Remote Keypad with Blue LCD Display

H100 mm x W145 mm x D35mm (always hardwired)

Keyfob

H45 mm x W30 mm x D2mm

External Wireless Self-Actuating Siren with Flashing StrobeH285mm x W282mm x D63mm

Grade 2 Wireless Digital Passive Infra Red Movement Detector

H117 mm x W69 mm x D50mm (wireless)

Grade 2 Wireless Dual Technology Detector

H117 mm x W69 mm x D59mm (wireless)

KF4-WE Two Way Wireless Keyfob

H60 mm x W40 mm x D15mm

Handheld Remote Digital Setting Device

H60 mm x W40 mm x D15mm

Page 5: INTRUDER ALARMS - Banham · PDF fileto false alarms. Grade 2 Class 2. H123 x W72 x D57 Detection area 12m x 12m ... a wireless portable panic button and wireless external self actuating

BANHAM AFTER SALES SERVICE

Monitoring Options

Banham provides 24 hour monitoring for all types of alarm systems through our own in-house Alarm Receiving Centre (ARC). We monitor systems including Intruder, Fire, CCTV, Panic, Freezer, Medical, Power Failure, Vaults, Opening and Closing Management, Flood Warning, Access Control, Ambient Temperature, Humidity Level, Machinery monitoring, Controlled Environment Monitoring. You can choose your own level of response:

1) Fully Monitored System with keyholder and 24 hour Police response:

If your alarm system is activated and a confirmed signal is received by our ARC (subject to the response level), the Police will be automatically notified and will respond. A confirmed signal means that the system must generate two independent alarm activations before the call can be passed on for a Police Response. Our ARC controllers will contact the premises to verify the activation. If the private passcode for the premises cannot be confirmed within a set time, the Police response will be confirmed to continue. The ARC will also contact keyholders nominated by the client to advise of an alarm activation of any kind.

2) Keyholder Response only:

Clients who do not require Police response but would like the added security of either themselves or their nominated keyholders being contacted following an alarm activation, can have the system more-or-less designed to meet their own requirements, subject to insurer’s approval if necessary. Temporary monitoring is also an option, but is only available through a digital communicator connection. If you are unable to provide private keyholders, Banham can undertake this service through their own professional keyholding company CMS Keyholding. Our team of keyholders on motorbikes are available 24 hours a day, 365 days a year and are ready to respond to any emergency situation.

3) Keyholder Response with PAB to Police:

Clients who do not want their system fully connected to the Police but who want the extra peace of mind of being able to reach the Police in an absolute emergency can opt to have just their Panic Button connected for a Police response - this option is only available through a Digital Communicator connection. (Note: Banham can also provide ‘bells only systems’ with a Panic Button only to the Police, subject to a telephone line being connected).

AN IMPORTANT FEATURE OF THE INSPECTION IS THE CHECKING OF THE BATTERIES, AND CONTACTS WITHIN THE SYSTEM, WHICH ARE REPLACED AS NECESSARY FREE OF CHARGE.

(EXCLUDING WIRELESS).

THE BANHAM GUARANTEE:Lifetime Guarantee: We offer a lifetime guarantee on any system connected to the Alarm Receiving Centre on a full police monitored contract.

Charges: None of our communication devices utilise premium rate lines.

Technical Support: Technical phone support and remote resets are free for maintained customers.

Annual Routine Maintenance Inspection

All Banham Intruder alarms can be designed to comply with BS 8243:2010, EN50131-1/PD 6662/BS 8263:2010 and the requirements laid down by the National Security Inspectorate (NSI). It may be a requirement of your insurance policy that your system is covered by a routine maintenance contract, for which you may be eligible for a discount on your contents insurance cover. Depending on your requirements, we offer a number of contract options:

1 maintenance visit a year:Systems without remote signalling (bells only) require just one visit.

2 maintenance visits a year:If your system in connected to the Alarm Receiving Centre (ARC) for Police response, it is a Police and NSI requirement that the system must be subject to two inspection visits per annum. (One can be remote providing the system is not Grade 3).

Automatic Remote Maintenance (ARM)

Using ARM Banham can verify that your entire security system is fully functional providing complete peace of mind in your security arrangements. You can choose one of your two annual inspections to be carried out using ARM. This option is operated in accordance with DD263:2010.

Secure and Convenient ARM enhances your security by constantly checking on the electrical status and functional capability of the alarm system.

Formal reportingAt a preset time, the control panel will call the host server and upload a full report on the status of your system. This report may be printed and copied to you, if required. Regular reporting by your alarm system to Banham takes the inconvenience out of service visits, and ensures the system is always operating at its peak performance level.

Full Signalling and Warning AnalysisThe correct operation of signalling equipment to the Alarm Receiving Centre is reassured along with a full test of the external sounders, initiated by the user.

Latest TechnologyARM software incorporates both BS 8243:2010 and EN 50131-1:2010 PD 6662/ BS 8243:2010 to conform with the current Police and European requirements on false alarm reduction and system design.

Detector performance analysisAll detectors are regularly checked to ensure your complete protection. Regular reminders to walk-test the system are given, which includes an automated system health check.

is available 24 hours a day with attendance within 4 hours if required. All our engineers are equipped with on-board portable computers, which relay real-time information relating to your service requirements. Details of the visit are then instantly relayed back to our control centre.

Optional extended warranty:This contract provides free service for the maintenance of intruder alarm system 24 hours a day, to include parts and labour, and a lifetime guarantee on systems connected to the ARC on a full Police monitored contract (subject to conditions).

What is involved in your maintenance inspection?:Calls are pre-booked by Banham and notified well in advance to give clients the opportunity to contact us, if the pre-arranged date is inconvenient. During the maintenance visit, the intruder alarm is tested to ensure that it is functioning correctly. Any developing fault found would be rectified accordingly at no charge other than for replacement components which areoutside the 12 month guarantee period. Our emergency service department

Page 6: INTRUDER ALARMS - Banham · PDF fileto false alarms. Grade 2 Class 2. H123 x W72 x D57 Detection area 12m x 12m ... a wireless portable panic button and wireless external self actuating

ALARM RECEIVING CENTRE (ARC)

Communication DevicesChoose what type of communication link your alarm system has to our ARC.Banham provides 24 hour monitoring for all types of alarm systems.

DUV/G Dualcom Vodafone is a dual path communication link between your property and the ARC. The normal landline (any analogue service provider) and also the Vodafone/PAKNET/GPRS radio network combine to provide an increased level ofsecurity. This is actively promoted by both Crime Prevention Officers and insurance companies alike. The unit requires an aerial, the location of which is subject to an engineer site environment test.

DIGIAIR An advanced auto dialling digital communication device for secure alarm reporting. It is supplied as a single path alarm transmission system (ATS) supplied with a world sim card. It eliminates the requirement for a telephone line subject to signal strength.

EM2 EMIZON IP is a dual path alarm signallingservice utilising a broadband connection. EMIZON IP continuously monitors the connection between the intruder alarm and the Alarm Receiving Centre. In the event of the IP network path being compromised either accidentally or deliberately, then signalling will be sent via the wireless GPRS Network.

GPRS Single Path GPRS Communicator utilising a world sim for improved network coverage. Ideal for locations where a PSTN or IP wired infrastructure is not available.

SIA 3

As standard at installation all communications systems are installed with SIA 3 communication protocol which provides an itemised audit trail of events following an activation. This service is free for the first year with continuation subject to client approval thereafter.

DC Digital Communicator is a single pathcommunication link between your property and the ARC, which can utilise any network provider, either an existing standard analogue broadband line or an exclusive dedicated out going only linefor increased security.

CA BT Redcare offers the same features as Digital Communicator but if a line fault occurs, a warning will be displayed in our ARC, which is then subject to Keyholder response only unless preceded by an intruder activation. Please note however that this option can only be used with a BT analogue line.

Clients who do not require Police response but would like the added security and peace of mind of either themselves or their nominated keyholder being contacted following an alarm activation, can have the system more-or-less designed to meet their own requirements, subject to insurer’s approval if necessary. Temporary monitoring is also an option. The Police policy described opposite is therefore not a requirement. For further details of the available options, our security surveyors will be able to advise you.

With monitored systems, the ARC will contact keyholders nominated by the client to advise of an alarm activation of any kind. If you are unable to provide private keyholders, Banham can undertake this service through their wholly owned subsidiary, CMS Keyholding (Tel: 020 7627 0344). CMS provide a team of professional keyholders on motorbikes available 24 hours a day, 365 days a year ready to respond to any emergency situation.

Keyholding / Alarm Response

Monitored Alarms with Keyholder Response Only

Tel: 020 7627 0344

Alarm Triggered

Emergency ServicesCan be noti�ed if required

Keyholder Response OnlyWe will notify keyholder/s which

can be CMS Keyholding (a Banham Group Company)

Keyholder Response with PAB to PoliceWe will notify your keyholder/s

and the Police if your panic button is triggered

(mobile panic buttons are also available) Alarm Veri�edBy our in-house Alarm Receiving Centre

24HR MONITORING7 DAYS A WEEK

SignalSent

Page 7: INTRUDER ALARMS - Banham · PDF fileto false alarms. Grade 2 Class 2. H123 x W72 x D57 Detection area 12m x 12m ... a wireless portable panic button and wireless external self actuating

INFORMATION RELATING TO THE DESIGN ANDINSTALLATION OF YOUR INTRUDER ALARM SYSTEM

In an effort to reduce the number of wasted Police visits to sites following false alarms, the National Police Chiefs Council (NPCC) have introduced certain design and operational requirements in order to help relieve Police resources.

In brief, these requirements cover three separate aspects of the intruder alarm, which are as follows:-

Alarm Unsetting

Statistics suggest that 94% of Police visits to site are generated by incorrect operation of the alarm keypad. In order to combat this problem NPCC insist that all systems must be unset via a single action method, such as a keyfob or keyswitch. We recommend the proximity keyfob as being the most user friendly and efficient of the available options. Clients who are unconvinced that this requirement is workable for them and who at point of survey insist upon designing the system for code number operation must understand that:-

A Where an intrusion occurs via a final exit, all means of alarm confirmation will be isolated. This means that the whole property will be vulnerable with the only action available being that of keyholder response.

B Systems of a similar design, but with keyfob operation, will only have entry/exit routes devices disabled. All other devices are then available to provide the first and second activation necessary to support the confirmed alarm signal.

Confirmed Alarm Signals

Since the introduction of the October 2001 NPCC Policy all new intruder alarm systems connected to the ARC must be designed to provide a confirmed alarm signal before the Police will respond.

This means that the system must generate two independent alarm activations before the call can be passed to the Police as a confirmed alarm. Banham achieve a confirmed alarm signal by using a sequential format i.e. two devices activating in sequence. We find this to be the most user friendly means of conforming with the NPCC Policy BS 8243:2010.

Compliance with the NPCC Policy BS 8243:2010

Police Response to Intruder Alarms

NPCC categorise all monitored intruder alarms into the following response levels:-

Immediate Response.

The Police will attend on the assumption that an offence is taking place, but against a background of competing urgent calls and available Police resources.

No Police attendance.

Following two false Hold up / Panic Alarms or three false confirmed Intruder Alarms within a 12 month period, the occupier will be advised by the Police that the system will have response withdrawn to this particular signal (Hold up / Panic or Intruder Alarm). Response will be reinstated once the following conditions have been met.

The Police will require a written application from Banham Alarms supported by evidence that the system has been free of false alarms for three (3) months, and the cause of the false alarms has been rectified.

As an alternative to the lack of Police response and subject to approval by insurers, it is possible to employ a professional keyholding company in the event of alarm activations and in the absence of Police response. For further details please contact our subsidiary company, CMS Keyholding on 020 7627 0344. They can offer a guaranteed response with the added peace of mind that whatever the circumstances on site, their Key Guard will co-ordinate matters and ensure the continued security of the premises.

NPCC demand that a site safety hazard letter is signed and returned by the client advising them of any known or potential site hazards which may endanger the safety of any officers who attend site. Application for a Unique Reference Number (URN) will begin once this has been received together with payment of the Police charge.

From 1st June 2012, systems that require NSI Certification must be designed and installed to comply with

BS 8243:2010 EN 50131-1:2010/PD 6662. This will include the requirement for an insurance risk assessment to be

undertaken, which will assist in determining the grade of the system and equipment required for the premises.

Compliance with European Standards EN 50131-1:2010/PD 6662

(BS 8243:2010) (DD263:2010)

(BS 8243:2010 Released 2010 implemented in July 2012)

For 8 consecutive years Banham have been awarded the coveted Metropolitan Police Gold & Silver Awards for the low number of false Police activations, highlighting the quality of our installations.

ENVIRONMENTAL RESPONSIBILITIES:The Banham Group understand the importance of sustainability & protecting the environment. All Banham Group companies are committed to

ensuring that their operational and business responsibilities are in compliance with current British & EU legislation, including the safe dismantling & disposal of equipment such as batteries.

Page 8: INTRUDER ALARMS - Banham · PDF fileto false alarms. Grade 2 Class 2. H123 x W72 x D57 Detection area 12m x 12m ... a wireless portable panic button and wireless external self actuating

EMERGENCY LOCKSMITHS•

REGISTERED KEY DOOR LOCKS•

WINDOW LOCKS•

SECURITY GRILLES•

COLLAPSIBLE GATES•

ROLLER SHUTTERS / GARAGE DOORS•

SAFES AND GUN CABINETS•

SECURITY DOORS•

FIRE & ASPIRATION SYSTEMS•

AUDIO ENTRY SYSTEMS•

VIDEO ENTRY SYSTEMS•

ACCESS CONTROL & BARRIER SYSTEMS•

CCTV SYSTEMS WITH DIGITAL RECORDING / ARC MONITORING / REMOTE VIEWING•

KEYHOLDING / ALARM RESPONSE SERVICE•

KEY DELIVERY SERVICE•

CLOSE PROTECTION AND SURVEILLANCE•

RAID CONTROL SYSTEMS•

DNA DETECTION SYSTEMS•

CONCIERGE SERVICES•

FOGGING SYSTEMS

BANHAM ALSO PROVIDE THE FOLLOWING SERVICES & PRODUCTS

Head Office & Administration20 Thornsett Road, London SW18 4EF Tel: 020 7622 5151 Fax: 020 7101 7707

Web: www.banham.co.uk Email: [email protected]

Central London Showroom233/235 Kensington High Street, London W8 6SF

Tel: 020 7622 5151 Fax: 020 7376 1232

North London Showroom51 Golders Green Road, Golders Green NW11 8EL

Tel: 020 8905 5405 Fax: 020 8209 0042

Thames Valley Showroom36 High Street, Maidenhead, Berks SL6 1QE

Tel: 01628 784151 Fax: 01628 784926

South of England Showroom20 Chertsey Street, Guildford, Surrey GU1 4HD

Tel: 01483 301400 Fax: 01483 302323

Security 201 Showroom332 Goring Road, Goring-by-Sea, West Sussex BN12 4PE

Tel: 01903 242902 Fax: 01903 242618Web: www.security201.co.uk

Email: [email protected]

Bridger Security1st Floor Offices, Wessenden Business Centre,

Prospect Road, Alresford, Hampshire SO24 9QF Tel: 01962 733231

Web: www.bridgersecurity.co.uk Email: [email protected]

* CMS Keyholding Ltd, part of the Banham Group, are an SIA Approved Contractor

Modular SchemeSP203 – Part 1

CAMESAFECOMPANY

Banham Security #1956

Confirm my ID: CAMESAFE.com

Also at: Brighton Tel: 01273 818311