HSVF Trouble Manual(Ver-0) 20111223

32
Hyundai Elevator Co., Ltd. HSVF SYSTEM REV.0 2011.12.23 TITLE File Name : HSVF Trouble manual HSVF Trouble manual HSVF Trouble manual HSVF Trouble manual HSVF SERIES HSVF SERIES HSVF SERIES HSVF SERIES TROUBLESHOOTING MANUAL TROUBLESHOOTING MANUAL TROUBLESHOOTING MANUAL TROUBLESHOOTING MANUAL Document Number : Rev. Commemts : HELCO-C5-003-01 -1- A4(210 ×297 ) HSVF SERIES HSVF SERIES HSVF SERIES HSVF SERIES TROUBLESHOOTING MANUAL TROUBLESHOOTING MANUAL TROUBLESHOOTING MANUAL TROUBLESHOOTING MANUAL This manual is the property of Hyundai Elevator Co., Ltd and is loaned subject to return upon demand. Contents of this publication shall not be reproduced in any form without written permission of Hyundai Elevator Co., Ltd. HYUNDAI ELEVATOR CO., LTD. HYUNDAI ELEVATOR CO., LTD. HYUNDAI ELEVATOR CO., LTD. HYUNDAI ELEVATOR CO., LTD.

description

manual de fallas elevador hYUNDAI modelo HSVF

Transcript of HSVF Trouble Manual(Ver-0) 20111223

  • Hyundai Elevator Co., Ltd. HSVF SYSTEM

    REV.0 2011.12.23TITLE File Name :HSVF Trouble manualHSVF Trouble manualHSVF Trouble manualHSVF Trouble manual

    HSVF SERIESHSVF SERIESHSVF SERIESHSVF SERIESTROUBLESHOOTING MANUALTROUBLESHOOTING MANUALTROUBLESHOOTING MANUALTROUBLESHOOTING MANUAL

    Document Number :

    Rev. Commemts :

    HELCO-C5-003-01 - 1 - A4(210 297 )

    HSVF SERIESHSVF SERIESHSVF SERIESHSVF SERIESTROUBLESHOOTING MANUALTROUBLESHOOTING MANUALTROUBLESHOOTING MANUALTROUBLESHOOTING MANUAL

    This manual is the property of Hyundai Elevator Co., Ltdand is loaned subject to return upon demand.Contents of this publication shall not be reproduced in anyform without written permission of Hyundai Elevator Co., Ltd.

    HYUNDAI ELEVATOR CO., LTD.HYUNDAI ELEVATOR CO., LTD.HYUNDAI ELEVATOR CO., LTD.HYUNDAI ELEVATOR CO., LTD.

  • Hyundai Elevator Co., Ltd. HSVF SYSTEM

    REV.0 2011.12.23TITLE File Name :HSVF Trouble manualHSVF Trouble manualHSVF Trouble manualHSVF Trouble manual

    HSVF SERIESHSVF SERIESHSVF SERIESHSVF SERIESTROUBLESHOOTING MANUALTROUBLESHOOTING MANUALTROUBLESHOOTING MANUALTROUBLESHOOTING MANUAL

    Document Number :

    Rev. Commemts :

    HELCO-C5-003-01 - 2 - A4(210 297 )

    TABLE OF CONTENTSTABLE OF CONTENTSTABLE OF CONTENTSTABLE OF CONTENTS1. INTRODUCTION1. INTRODUCTION1. INTRODUCTION1. INTRODUCTION 3333

    1-1. Main feature1-1. Main feature1-1. Main feature1-1. Main feature 3333

    2. INSTALLATION2. INSTALLATION2. INSTALLATION2. INSTALLATION 33332-1. Safety2-1. Safety2-1. Safety2-1. Safety 3333

    3. BOARDS ADJUSTMENT3. BOARDS ADJUSTMENT3. BOARDS ADJUSTMENT3. BOARDS ADJUSTMENT 55553-1. MCU Board & PIO Board Adjustment3-1. MCU Board & PIO Board Adjustment3-1. MCU Board & PIO Board Adjustment3-1. MCU Board & PIO Board Adjustment 55553-2. GIO Board Adjustment3-2. GIO Board Adjustment3-2. GIO Board Adjustment3-2. GIO Board Adjustment 66663-3. TNP Board Adjustment3-3. TNP Board Adjustment3-3. TNP Board Adjustment3-3. TNP Board Adjustment 88883-4. CCB-7 Board Adjustment3-4. CCB-7 Board Adjustment3-4. CCB-7 Board Adjustment3-4. CCB-7 Board Adjustment 101010103-5. OPB-340 Board Adjustment3-5. OPB-340 Board Adjustment3-5. OPB-340 Board Adjustment3-5. OPB-340 Board Adjustment 111111113-6. HPI/HIP CAN Board Adjustment3-6. HPI/HIP CAN Board Adjustment3-6. HPI/HIP CAN Board Adjustment3-6. HPI/HIP CAN Board Adjustment 121212123-7. Voice Synthesizer3-7. Voice Synthesizer3-7. Voice Synthesizer3-7. Voice Synthesizer 151515153-8. CPI-CAN Board Adjustment3-8. CPI-CAN Board Adjustment3-8. CPI-CAN Board Adjustment3-8. CPI-CAN Board Adjustment 161616163-9. LS Board Adjustment3-9. LS Board Adjustment3-9. LS Board Adjustment3-9. LS Board Adjustment 17171717

    4. INSPECTION OPERATION4. INSPECTION OPERATION4. INSPECTION OPERATION4. INSPECTION OPERATION 181818184-1. Brake line connection4-1. Brake line connection4-1. Brake line connection4-1. Brake line connection 181818184-2. Power line connection4-2. Power line connection4-2. Power line connection4-2. Power line connection 181818184-3. Motor line connection4-3. Motor line connection4-3. Motor line connection4-3. Motor line connection 181818184-4. Check points after turning on the power4-4. Check points after turning on the power4-4. Check points after turning on the power4-4. Check points after turning on the power 181818184-5. Operate Inspection4-5. Operate Inspection4-5. Operate Inspection4-5. Operate Inspection 19191919

    5. INITIALIZING OPERATION5. INITIALIZING OPERATION5. INITIALIZING OPERATION5. INITIALIZING OPERATION 202020205-1. Purpose5-1. Purpose5-1. Purpose5-1. Purpose 202020205-2.5-2.5-2.5-2. Check subjectsCheck subjectsCheck subjectsCheck subjects 202020205-3. Operating Procedure5-3. Operating Procedure5-3. Operating Procedure5-3. Operating Procedure 212121215-4. Cautious Subjects5-4. Cautious Subjects5-4. Cautious Subjects5-4. Cautious Subjects 212121215-5. Initialization Flow Chart5-5. Initialization Flow Chart5-5. Initialization Flow Chart5-5. Initialization Flow Chart 22222222

    6. LOAD COMPENSATING DEVICE SETUP6. LOAD COMPENSATING DEVICE SETUP6. LOAD COMPENSATING DEVICE SETUP6. LOAD COMPENSATING DEVICE SETUP 232323236666-1. Purpose-1. Purpose-1. Purpose-1. Purpose 232323236-2. Procedure6-2. Procedure6-2. Procedure6-2. Procedure 23232323

  • Hyundai Elevator Co., Ltd. HSVF SYSTEM

    REV.0 2011.12.23TITLE File Name :HSVF Trouble manualHSVF Trouble manualHSVF Trouble manualHSVF Trouble manual

    HSVF SERIESHSVF SERIESHSVF SERIESHSVF SERIESTROUBLESHOOTING MANUALTROUBLESHOOTING MANUALTROUBLESHOOTING MANUALTROUBLESHOOTING MANUAL

    Document Number :

    Rev. Commemts :

    HELCO-C5-003-01 - 3 - A4(210 297 )

    1. INTRODUCTION1. INTRODUCTION1. INTRODUCTION1. INTRODUCTION

    * The manual describes the troubleshooting method of Hyundai "HSVF" elevator system.* The manual describes the troubleshooting method of Hyundai "HSVF" elevator system.* The manual describes the troubleshooting method of Hyundai "HSVF" elevator system.* The manual describes the troubleshooting method of Hyundai "HSVF" elevator system.

    * In this manual, elevator troubles are explained in two cases i.e.* In this manual, elevator troubles are explained in two cases i.e.* In this manual, elevator troubles are explained in two cases i.e.* In this manual, elevator troubles are explained in two cases i.e.* "Condition of operation impossible" means the impossible state of starting and running of* "Condition of operation impossible" means the impossible state of starting and running of* "Condition of operation impossible" means the impossible state of starting and running of* "Condition of operation impossible" means the impossible state of starting and running ofelevator by certain causes of troubles.elevator by certain causes of troubles.elevator by certain causes of troubles.elevator by certain causes of troubles.

    * "Condition of operation possible" means the possible state of running, but normal service for* "Condition of operation possible" means the possible state of running, but normal service for* "Condition of operation possible" means the possible state of running, but normal service for* "Condition of operation possible" means the possible state of running, but normal service forpassenger's is not made by several causes of troubles.passenger's is not made by several causes of troubles.passenger's is not made by several causes of troubles.passenger's is not made by several causes of troubles.

    * As troubles are describes by trouble modes and causes of troubles and troubleshooting* As troubles are describes by trouble modes and causes of troubles and troubleshooting* As troubles are describes by trouble modes and causes of troubles and troubleshooting* As troubles are describes by trouble modes and causes of troubles and troubleshootingmethods are explained.methods are explained.methods are explained.methods are explained.

    * This manual shall be helpful for prompt and accurate troubleshooting of the troubles that* This manual shall be helpful for prompt and accurate troubleshooting of the troubles that* This manual shall be helpful for prompt and accurate troubleshooting of the troubles that* This manual shall be helpful for prompt and accurate troubleshooting of the troubles thatcould happen at jobsite.could happen at jobsite.could happen at jobsite.could happen at jobsite.

    * System power and Boards are explained in "HSVF INSTALLATION MANUAL AND ADJUSTMENT* System power and Boards are explained in "HSVF INSTALLATION MANUAL AND ADJUSTMENT* System power and Boards are explained in "HSVF INSTALLATION MANUAL AND ADJUSTMENT* System power and Boards are explained in "HSVF INSTALLATION MANUAL AND ADJUSTMENTMANUAL"MANUAL"MANUAL"MANUAL"

    * HHT use methods are explained in "HSVF HHT MANUAL".* HHT use methods are explained in "HSVF HHT MANUAL".* HHT use methods are explained in "HSVF HHT MANUAL".* HHT use methods are explained in "HSVF HHT MANUAL".

  • Hyundai Elevator Co., Ltd. HSVF SYSTEM

    REV.0 2011.12.23TITLE File Name :HSVF Trouble manualHSVF Trouble manualHSVF Trouble manualHSVF Trouble manual

    HSVF SERIESHSVF SERIESHSVF SERIESHSVF SERIESTROUBLESHOOTING MANUALTROUBLESHOOTING MANUALTROUBLESHOOTING MANUALTROUBLESHOOTING MANUAL

    Document Number :

    Rev. Commemts :

    HELCO-C5-003-01 - 4 - A4(210 297 )

    2. TROUBLESHOOING METHOD WITH HHT2. TROUBLESHOOING METHOD WITH HHT2. TROUBLESHOOING METHOD WITH HHT2. TROUBLESHOOING METHOD WITH HHT

    2-1. Connection and initialization of HHT2-1. Connection and initialization of HHT2-1. Connection and initialization of HHT2-1. Connection and initialization of HHT1) Connect HHT to MCU "H8" connector at elevator stopped.2) Push "ESC" and "ENTER" key for 1 seconds simultaneously.3) Then, HHT initial menu is displayed normally.4) Please refer to "STVF7 HHT MANUAL".

    IDIDIDID HHT Main MenuHHT Main MenuHHT Main MenuHHT Main Menu RemarkRemarkRemarkRemark0. EL.STATUS Total Information Mode

    1. IN/OUT PIO I/O, Car I/O, Call I/O, INVERTER I/O, RMS I/O,Group I/O, CAN STATUS, EXT I/O2. ERROR Error, Error records, Erasing records, Hall Error

    3. SETUP Spec. change, Device set up, Time set up,Initialization, Load set up4. MANAGEMENT Field test, Factory test, Count E/L running times5. INFO Version information

    [Table 1. HHT Main Menu][Table 1. HHT Main Menu][Table 1. HHT Main Menu][Table 1. HHT Main Menu]

  • Hyundai Elevator Co., Ltd. HSVF SYSTEM

    REV.0 2011.12.23TITLE File Name :HSVF Trouble manualHSVF Trouble manualHSVF Trouble manualHSVF Trouble manual

    HSVF SERIESHSVF SERIESHSVF SERIESHSVF SERIESTROUBLESHOOTING MANUALTROUBLESHOOTING MANUALTROUBLESHOOTING MANUALTROUBLESHOOTING MANUAL

    Document Number :

    Rev. Commemts :

    HELCO-C5-003-01 - 5 - A4(210 297 )

    2-2. Total Information Mode2-2. Total Information Mode2-2. Total Information Mode2-2. Total Information Mode

    C 1 3 5 6 7 8 11 15 16V1 AAAA uuuu CCCC DDDD 2222 (((( BBBB 1111 )))) //// 3333 33332 FFFF 6666 8888 [[[[ 0000 9999 :::: 2222 5555 ]]]]

    PositionPositionPositionPosition CommitCommitCommitCommit DisplayDisplayDisplayDisplay

    1verse1,2 column Elevator Status

    NoNoNoNo no mode F1F1F1F1 1st fireman op.AuAuAuAu auto F2F2F2F2 2nd fireman op.InInInIn In-Car inspection MvMvMvMv independent op.OnOnOnOn On-Car inspection EpEpEpEp Emergency op.McMcMcMc Machine roominspection ElElElEl

    EmergencyLanding op.

    FiFiFiFi Initialization EqEqEqEq Earthquake op.PkPkPkPk Parking op. RpRpRpRp Sub brake inFrFrFrFr Fireman Return ArArArAr Arrange op.

    1verse3,4 column Door Status

    OGOGOGOG Openning RGRGRGRG Rear Door OpenningOPOPOPOP Open RORORORO Rear Door OpenCGCGCGCG Closing RCRCRCRC Raer Door CloseCDCDCDCD Close

    1v 5c Direction : Up, : Stop, : Down1v 6c Door zone sensor ULA, DZ, DLA1v 7c Non-Stop Floor (Space) : Service Floor, **** : non-Service Floor1v 8,9c Absolute Floor1v 11~12c Floor display Floor display on Indicator1v 15,16c Total Floor2v 1,2,3c Error display ------------: No error, FxxFxxFxxFxx: error code2v 11~15c Current time Hour : Minute

    [Table 2. Total Information Mode][Table 2. Total Information Mode][Table 2. Total Information Mode][Table 2. Total Information Mode]

  • Hyundai Elevator Co., Ltd. HSVF SYSTEM

    REV.0 2011.12.23TITLE File Name :HSVF Trouble manualHSVF Trouble manualHSVF Trouble manualHSVF Trouble manual

    HSVF SERIESHSVF SERIESHSVF SERIESHSVF SERIESTROUBLESHOOTING MANUALTROUBLESHOOTING MANUALTROUBLESHOOTING MANUALTROUBLESHOOTING MANUAL

    Document Number :

    Rev. Commemts :

    HELCO-C5-003-01 - 6 - A4(210 297 )

    2-3. IN/OUT MODE2-3. IN/OUT MODE2-3. IN/OUT MODE2-3. IN/OUT MODE(1) Method of checking IN/OUT statusex) : 1.1 PIO input status

    PPPP IIII OOOO IIII NNNN PPPP UUUU TTTT (((( 0000 )))) PIO Input (0) modePIO Input (0) modePIO Input (0) modePIO Input (0) mode0000 XXXX 0000 0000 CCCC 2222 0000 0000 1111 7777 DATA : 32bit hex value

    (a)(a)(a)(a)(b)(b)(b)(b)(a)(a)(a)(a) (b)(b)(b)(b)(a)(a)(a)(a)(b)(b)(b)(b)(a)(a)(a)(a) (b)(b)(b)(b)

    -(b) : 7 => 29,41,40 : ON-(a) : 1 => AUTO : ON-(b) : 2 => FMR : ON-(a) : C => MCI,MC2I : ON

    * It is same as the other in/out mode.* It is same as the other in/out mode.* It is same as the other in/out mode.* It is same as the other in/out mode.(2) PIO Input (1. IN/OUT >> 1-1. PIO Input)

    HHTHHTHHTHHTSIGNAL NAMESIGNAL NAMESIGNAL NAMESIGNAL NAME

    (a)(a)(a)(a) (b)(b)(b)(b)8888 4444 2222 1111 8888 4444 2222 1111bit8bit8bit8bit8 bit7bit7bit7bit7 bit6bit6bit6bit6 bit5bit5bit5bit5 bit4bit4bit4bit4 bit3bit3bit3bit3 bit2bit2bit2bit2 bit1bit1bit1bit1

    PIO Input [0] MDN MUP MCS AUTO BKOP 40 41 29 DLS PLDL PLDH PLDM PLUM PLUH PLUL ULS MC2I MCI ELDI EQP EQS PARK FMR RBKI BKB FMR2 RDZ FDZ EMPO HOME ATS MT

    PIO Input [1] PDN PUP PHAND PAUTO RNBL WLS PDLS CTOL

    PIO Input [2] 30B BKS ZSP RUN DLD DLA DZ ULA

    [Table 3. PIO Input][Table 3. PIO Input][Table 3. PIO Input][Table 3. PIO Input]a. If elevator is in machine room inspection, check that "PIO Input[0]" iswhether - - - - - - 2 7 or not. (MCS, 40, 41, 29)

    b. If limit switches are in good condition, check that "PIO Input[0]" iswhether - - - - E 7 - - or not. (DLS, PLDL, PLDH, PLUH, PLUL, ULS)

    c. If door zone sensors are in good condition, check that "PIO Input[2]" iswhether - - - - - - - 7 or not. (DLA, DZ, ULA)

    d. If inverter is in good condition at stopped, check that "PIO Input[2]" iswhether - - - - - - A - or not. (30B, ZSP)

  • Hyundai Elevator Co., Ltd. HSVF SYSTEM

    REV.0 2011.12.23TITLE File Name :HSVF Trouble manualHSVF Trouble manualHSVF Trouble manualHSVF Trouble manual

    HSVF SERIESHSVF SERIESHSVF SERIESHSVF SERIESTROUBLESHOOTING MANUALTROUBLESHOOTING MANUALTROUBLESHOOTING MANUALTROUBLESHOOTING MANUAL

    Document Number :

    Rev. Commemts :

    HELCO-C5-003-01 - 7 - A4(210 297 )

    (3) PIO Output (1. IN/OUT >> 1-2. PIO Output)HHTHHTHHTHHT SIGNAL NAMESIGNAL NAMESIGNAL NAMESIGNAL NAME

    PIO Output [0]REV FWD MC2 MC1 RBK BRKA

    XRLY MFAN SPO2 SPO1 ELDO BRKC BRKB ALARMRST INIT

    [Table 4. PIO Output][Table 4. PIO Output][Table 4. PIO Output][Table 4. PIO Output]a. If elevator is stopped, check that "PIO Output[0]" is

    whether - - - - - - - 6 or not. (MC1, RBK)

    * SSVF7 : - - - - - - - E (MC2, MC1, RBK)b. If elevator is moving upward, check that "PIO Output[0]" is

    whether - - - - - - 1 7 or not. (FWD, MC1, RBK, BRKA)

    * SSVF7 : - - - - - - 1 F (FWD, MC2, MC1, RBK, BRKA)

    (4) Car Input (1. IN/OUT >> 1-3. Car Input)HHTHHTHHTHHT Signal NameSignal NameSignal NameSignal Name

    CarSigIn [0]FC5 NDZ FC3 FR2 FR1 ONDN ONUP ONSOL FULL L70 L30 EE SE DCL DOLDCS DCB DOB INS AUTO

    ODD EVEN EACH MOVE PASS ATT PWR

    CarSigIn [1]

    CarSigIn [2] REE RSE RDCL RDOLRDCS RDCB RDOB

    CarSigIn [3]

    [Table 5. Car Input][Table 5. Car Input][Table 5. Car Input][Table 5. Car Input]a. If inspection switch on the cage is on, check that "Car Input[0]"

    is whether - - - - - - - 1 or not. (ONS)b. If door open button is pushed, check that "Car Input[0]" is

    whether - - 1 - - - - - or not. (DOB)

  • Hyundai Elevator Co., Ltd. HSVF SYSTEM

    REV.0 2011.12.23TITLE File Name :HSVF Trouble manualHSVF Trouble manualHSVF Trouble manualHSVF Trouble manual

    HSVF SERIESHSVF SERIESHSVF SERIESHSVF SERIESTROUBLESHOOTING MANUALTROUBLESHOOTING MANUALTROUBLESHOOTING MANUALTROUBLESHOOTING MANUAL

    Document Number :

    Rev. Commemts :

    HELCO-C5-003-01 - 8 - A4(210 297 )

    (5) Car Output (1. IN/OUT >> 1-4. Car Output)HHTHHTHHTHHT Signal NameSignal NameSignal NameSignal Name

    CarSigOut [0]LTR VFR UDST FST FDR FR2R CLR OPRDST DDN DUP VOL LED3 LED2 LED1 OLBZ

    VEQ DLOCK VWEL VFD VIP NUDGR

    CarSigOut [1] BN2 VCL VOP LED4 RNUGR RCLR ROPR REAR

    VCNCL RDOORFDOOR

    CarSigOut [2]

    CarSigOut [3]

    [Table 6. Car output][Table 6. Car output][Table 6. Car output][Table 6. Car output]

    (6) CAN Status (1. IN/OUT >> 1-D. CAN Status)HHTHHTHHTHHT CommitCommitCommitCommit

    CAN.Car StatusCar part CAN status register value :* normal : 0x0000000C* abnormal : 0x80000044

    CAN.Hall StatusHall part CAN status register value :* normal : 0x0000000C* abnormal : 0x80000044

    HallScan1 1-32

    Normal/Front Hall detected ID 1~32 floor(Detected Hall ID bit is displayed "1")* example 8 floor = 0x000000FF* example 15 floor = 0x00007FFF

    HallScan1 33-64 Normal/Front Hall detected ID 33~64 floorHallScan2 1-32 Handicap/Rear Hall detected ID 1~32 floorHallScan2 33-64 Handicap/Rear Hall detected ID 33~64 floor

    Car Scan

    Detected ID of OPB board :*0xHGFEDCBAH G F E D C B A-- ExIO2 ExIO1 LS OPB4 OPB3 OPB2 OPB1

    [Table 7. CAN Status][Table 7. CAN Status][Table 7. CAN Status][Table 7. CAN Status]

  • Hyundai Elevator Co., Ltd. HSVF SYSTEM

    REV.0 2011.12.23TITLE File Name :HSVF Trouble manualHSVF Trouble manualHSVF Trouble manualHSVF Trouble manual

    HSVF SERIESHSVF SERIESHSVF SERIESHSVF SERIESTROUBLESHOOTING MANUALTROUBLESHOOTING MANUALTROUBLESHOOTING MANUALTROUBLESHOOTING MANUAL

    Document Number :

    Rev. Commemts :

    HELCO-C5-003-01 - 9 - A4(210 297 )

    2-4. ERROR MENU2-4. ERROR MENU2-4. ERROR MENU2-4. ERROR MENU

    IDIDIDID HHT DisplayHHT DisplayHHT DisplayHHT Display CommitCommitCommitCommit2.1 Error List Error occurrence / cancellation list2.2 Clear Error Clear error occurrence / cancellation list2.3 Hall Error Hall board error

    [Table 8. ERROR MENU][Table 8. ERROR MENU][Table 8. ERROR MENU][Table 8. ERROR MENU]1) Error List (2.ERROR >> 2.1 Error List)- Error list is recorded with error code, occurrence time, cancellation time in regularsequence.

    - The total number of recorded lists is 64.ex 1) 2009. 2. 17 15:55:47.11 F11 occurrence

    0000 0000 2222 FFFF 1111 1111 ssss eeee tttt0000 9999 0000 2222 1111 7777 ---- 1111 5555 5555 5555 4444 7777 .... 1111 1111

    ex 2) 2009. 2. 17 15:59:58.87 F11 cancellation

    0000 0000 1111 FFFF 1111 1111 cccc llll rrrr0000 9999 0000 2222 1111 7777 ---- 1111 5555 5555 9999 5555 8888 .... 8888 7777

    2) Clear Error (2.ERROR >> 2.2 Clear Error)- Clear the total 64 error records.ex) Clear Error /Cln Error List? push ? button

    select "yes" using ? button push ? buttonCCCC llll nnnn EEEE rrrr rrrr oooo rrrr LLLL iiii ssss tttt ????

    YYYY eeee ssss

  • Hyundai Elevator Co., Ltd. HSVF SYSTEM

    REV.0 2011.12.23TITLE File Name :HSVF Trouble manualHSVF Trouble manualHSVF Trouble manualHSVF Trouble manual

    HSVF SERIESHSVF SERIESHSVF SERIESHSVF SERIESTROUBLESHOOTING MANUALTROUBLESHOOTING MANUALTROUBLESHOOTING MANUALTROUBLESHOOTING MANUAL

    Document Number :

    Rev. Commemts :

    HELCO-C5-003-01 - 10 - A4(210 297 )

    3) Hall Error (2.ERROR >> 2.3 Hall Error)- Undetected or dis-order hall board ID bit is displayed "1".- Check the hall board. Refer to "STVF7 ADJUSTMENT MANUAL".

    HHTHHTHHTHHT CommitCommitCommitCommitHallErr.1 1-32 Normal/Front Hall error 1~32 floorHallErr.1 33-64 Normal/Front Hall error 33~64 floorHallErr.2 1-32 Handicap/Rear Hall error 1~32 floorHallErr.2 33-64 Handicap/Rear Hall error 33~64 floor

    ex) Hall ID error is detected at 1, 2, 6, 8 floor

    HHHH aaaa llll llll EEEE rrrr rrrr .... 1111 1111 ---- 3333 2222 Hall Err.1 1-32 modeHall Err.1 1-32 modeHall Err.1 1-32 modeHall Err.1 1-32 modeDATA : 32bit hex value0000 XXXX 0000 0000 0000 0000 0000 0000 AAAA 3333

    25~3217~24 9~16 1~8

    0X000000A3 " ---- 8 7 6 5 4 3 2 1 floorDATA "A3 " ---- 1 0 1 0 0 0 1 1

    * If there is no hall error, DATA is displayed 0x00000000.

  • Hyundai Elevator Co., Ltd. HSVF SYSTEM

    REV.0 2011.12.23TITLE File Name :HSVF Trouble manualHSVF Trouble manualHSVF Trouble manualHSVF Trouble manual

    HSVF SERIESHSVF SERIESHSVF SERIESHSVF SERIESTROUBLESHOOTING MANUALTROUBLESHOOTING MANUALTROUBLESHOOTING MANUALTROUBLESHOOTING MANUAL

    Document Number :

    Rev. Commemts :

    HELCO-C5-003-01 - 11 - A4(210 297 )

    3. ERROR CODES3. ERROR CODES3. ERROR CODES3. ERROR CODESF11F11F11F11 Safety Line ErrorSafety Line ErrorSafety Line ErrorSafety Line Error

    StateStateStateState- Safety line error(when elevator is stopped).- Impossible to move in inspection, auto operation and etc.,

    ReferenceReferenceReferenceReference- Elec.W.diagram : COL 3A, 3B, 3C, 4A- MCU Bd HHT : 1.IN/OUT >> 1.1 PIO Input >> PIO Input [0] "29"

    CheckCheckCheckCheckPointPointPointPoint

    - Check power supply DC110V, DC24V.- Check X29 relay of TNP board.- Check switches of safety line.- Check HHT 1.IN/OUT >> 1.1 PIO Input >> PIO Input [0] 29- Check H2,H3 cable between PIO board and TNP board.

    F21F21F21F21 Running Time ErrorRunning Time ErrorRunning Time ErrorRunning Time Error

    StateStateStateState- Available running time error- stop running impossible to move in any operation

    ReferenceReferenceReferenceReference- HHT : 3.SETUP>>3.1 basic>>31b Field>>B43 ATStall Time- HHT : 3.SETUP>>3.1 basic>>31b Field>>B01 Total FL Num

    CheckCheckCheckCheckPointPointPointPoint

    - Check brake operation.- Check the signal "FWD/REV" transmission from MCU to inverter.- Check the signal "BKS, RUN" of inverter.- Check inverter HHT "MONITOR>>Floor data>>1F ~ top floor.- Check total floor data between MCU and inverter.

    F31F31F31F31 DPRAM ErrorDPRAM ErrorDPRAM ErrorDPRAM Error

    StateStateStateState - DPRAM cable error between MCU and inverter

    ReferenceReferenceReferenceReference - Elec.W.diagram : COL 1A, 1B, 1C

    CheckCheckCheckCheckPointPointPointPoint

    - Check the DPRAM cable from MCU H6 to inverter CN7.- Check the DPRAM cable shield and ground.

  • Hyundai Elevator Co., Ltd. HSVF SYSTEM

    REV.0 2011.12.23TITLE File Name :HSVF Trouble manualHSVF Trouble manualHSVF Trouble manualHSVF Trouble manual

    HSVF SERIESHSVF SERIESHSVF SERIESHSVF SERIESTROUBLESHOOTING MANUALTROUBLESHOOTING MANUALTROUBLESHOOTING MANUALTROUBLESHOOTING MANUAL

    Document Number :

    Rev. Commemts :

    HELCO-C5-003-01 - 12 - A4(210 297 )

    F41F41F41F41 FWD/REV ErrorFWD/REV ErrorFWD/REV ErrorFWD/REV Error

    StateStateStateState- (in inspection) MCU commands to stop, but FWD/REV signal outputto inverter.

    - stop running "MC1" contactor off (turning inverter off)

    ReferenceReferenceReferenceReference- Elec.W.diagram : COL 1A, 1B, 1C- MCU HHT : 1.IN/OUT>>1.2 PIO Output>>PIO Output[0] "FWD","REV"- MCU HHT : 1.IN/OUT>>1.1 PIO Input>>PIO Input[2] "ZSP","RUN"

    CheckCheckCheckCheckPointPointPointPoint

    - Check "FWD","REV" signal of HHT and relay of PIO board.- Check inverter HHT "MONITOR>>I/O>>Y1,2,3".

    F51F51F51F51 "MC1" Contactor Error"MC1" Contactor Error"MC1" Contactor Error"MC1" Contactor Error

    StateStateStateState- MCU commands "MCX1" on, but "MC1" contactor is not on.- Impossible to move in any operation.

    ReferenceReferenceReferenceReference- Elec.W.diagram : COL 4A- MCU HHT : 1.IN/OUT>>1.1 PIO Input>>PIO Input[0] "MCI"- MCU HHT : 1.IN/OUT>>1.2 PIO Output>>PIO Output[0] "MC1"

    CheckCheckCheckCheckPointPointPointPoint

    - Check "MCX1" relay of TNP board.- Check PIO board.- Check "MC1" contactor connection.

    F61F61F61F61 "MC2" Contactor Stuck Error"MC2" Contactor Stuck Error"MC2" Contactor Stuck Error"MC2" Contactor Stuck Error

    StateStateStateState- MCU commands "MCX2" off, but "MC2" contactor is not off.- Impossible to move in any operation.

    ReferenceReferenceReferenceReference- Elec.W.diagram : COL 1C, 3C, 4A- MCU HHT : 1.IN/OUT>>1.1 PIO Input>>PIO Input[0] "MC2I"- MCU HHT : 1.IN/OUT>>1.2 PIO Output>>PIO Output[0] "MC2"

    CheckCheckCheckCheckPointPointPointPoint

    - Check "MC2" contacts have welded or not- Check "MC2" contactor connection.- Check "MCX2" relay of TNP board.- Check PIO board.

  • Hyundai Elevator Co., Ltd. HSVF SYSTEM

    REV.0 2011.12.23TITLE File Name :HSVF Trouble manualHSVF Trouble manualHSVF Trouble manualHSVF Trouble manual

    HSVF SERIESHSVF SERIESHSVF SERIESHSVF SERIESTROUBLESHOOTING MANUALTROUBLESHOOTING MANUALTROUBLESHOOTING MANUALTROUBLESHOOTING MANUAL

    Document Number :

    Rev. Commemts :

    HELCO-C5-003-01 - 13 - A4(210 297 )

    F71F71F71F71 Safety Line Error (While Running)Safety Line Error (While Running)Safety Line Error (While Running)Safety Line Error (While Running)

    StateStateStateState- Safety line error (when elevator is running).- Impossible to move in inspection, auto operation and etc.,

    ReferenceReferenceReferenceReference- Elec.W.diagram : COL 3A, 3B, 3C, 4A- MCU HHT : 1.IN/OUT>>1.1 PIO Input>>PIO Input[0] "29"

    CheckCheckCheckCheckPointPointPointPoint

    - Check power supply DC110V, DC24V.- Check X29 Relay of TNP board.- Check switches of safety line.- Check HHT 1.IN/OUT >> 1.1 PIO Input >> PIO Input [0] 29- Check H2,H3 cable between PIO board and TNP board.

    F81F81F81F81 Watchdog ErrorWatchdog ErrorWatchdog ErrorWatchdog Error

    StateStateStateState- MCU board fault- Impossible to move in inspection, auto operation and etc.,

    ReferenceReferenceReferenceReference - MCU "WDOG" LED

    CheckCheckCheckCheckPointPointPointPoint - Repair the MCU board

    F91F91F91F91 MCU Board ResetMCU Board ResetMCU Board ResetMCU Board Reset

    StateStateStateState - Displayed at that time of booting the MCU board

    ReferenceReferenceReferenceReference - None

    CheckCheckCheckCheckPointPointPointPoint

    - Check power supply AC 220V.- Check power input connector "CM1" of MCU board. (DC 5V)- Check the push button "RESET"

  • Hyundai Elevator Co., Ltd. HSVF SYSTEM

    REV.0 2011.12.23TITLE File Name :HSVF Trouble manualHSVF Trouble manualHSVF Trouble manualHSVF Trouble manual

    HSVF SERIESHSVF SERIESHSVF SERIESHSVF SERIESTROUBLESHOOTING MANUALTROUBLESHOOTING MANUALTROUBLESHOOTING MANUALTROUBLESHOOTING MANUAL

    Document Number :

    Rev. Commemts :

    HELCO-C5-003-01 - 14 - A4(210 297 )

    F12F12F12F12 MT_Thermal / CCS Switch ErrorMT_Thermal / CCS Switch ErrorMT_Thermal / CCS Switch ErrorMT_Thermal / CCS Switch Error

    StateStateStateState

    - Motor thermal activates in running F12 move to near door zone - Compensation chain switch activates in running F12 occurs

    move to near door zone- Possible to move in inspection.

    ReferenceReferenceReferenceReference- Elec.W.diagram : COL 4A (CCS/MT)- MCU HHT : 1.IN/OUT >> 1.1 PIO Input >> PIO Input [0] MT

    CheckCheckCheckCheckPointPointPointPoint

    - Check TH1,THC with tester.- Check MT relay.- Check CCS switch.

    F22F22F22F22 Floor data ErrorFloor data ErrorFloor data ErrorFloor data Error

    StateStateStateState- Floor data error in auto operation.- Impossible to move in auto operation.- Floor data error between MCU and inverter

    ReferenceReferenceReferenceReference- Elec.W.diagram : COL 1A, 1B, 1C- MCU HHT : 3.SETUP>>3.1Basic>>31b Field>>B01 Total FL Num- inverter HHT : PROGRAM>>CONTROL>>MAX FLOOR

    CheckCheckCheckCheckPointPointPointPoint

    - Check floor data between MCU and inverter.- Check DPRAM cable, shield and ground.

    F42F42F42F42 Initialization ErrorInitialization ErrorInitialization ErrorInitialization Error

    StateStateStateState - After initialization, inverter don't output high operation signal to MCU.

    ReferenceReferenceReferenceReference

    - Elec.W.diagram : COL 3A, 3B- MCU HHT : 1.IN/OUT >> 1.1 PIO Input >> PIO Input [0] ULS, DLS- Inverter HHT : MONITOR>>BASIC>>INIT OK

    : PROGRAM>>CONTROL>>MAX FLOOR

    CheckCheckCheckCheckPointPointPointPoint

    - Check the door zone sensor input.- Check the floor data of inverter "MAX FLOOR".- Check the limit switch position.

  • Hyundai Elevator Co., Ltd. HSVF SYSTEM

    REV.0 2011.12.23TITLE File Name :HSVF Trouble manualHSVF Trouble manualHSVF Trouble manualHSVF Trouble manual

    HSVF SERIESHSVF SERIESHSVF SERIESHSVF SERIESTROUBLESHOOTING MANUALTROUBLESHOOTING MANUALTROUBLESHOOTING MANUALTROUBLESHOOTING MANUAL

    Document Number :

    Rev. Commemts :

    HELCO-C5-003-01 - 15 - A4(210 297 )

    F52F52F52F52 Pulse ErrorPulse ErrorPulse ErrorPulse Error

    StateStateStateState- Pulse compensation error (500mm) in auto operation.- F42 move to near door zone

    ReferenceReferenceReferenceReference- Elec.W.diagram : COL 4A- MCU HHT : 1.IN/OUT >> 1.1 PIO Input >> PIO Input [2] ULA, DLA- Inverter HHT : MONITOR>>FLOOR DATA>>CURRENT POSITION

    CheckCheckCheckCheckPointPointPointPoint

    - Check the door zone sensor input.- Check the floor data of inverter "MAX FLOOR". ?- Check the limit switch position.

    F62F62F62F62 Vane Count ErrorVane Count ErrorVane Count ErrorVane Count Error

    StateStateStateState- In initialization, the number of door vane is different from total floor data.- Possible to move in inspection.

    ReferenceReferenceReferenceReference- Elec.W.diagram : COL 3A, 3B, 4A- MCU HHT : 1.IN/OUT >> 1.1 PIO Input >> PIO Input [0] ULS, DLS- MCU HHT : 1.IN/OUT >> 1.1 PIO Input >> PIO Input [2] DLA,DZ,ULA

    CheckCheckCheckCheckPointPointPointPoint

    - Check the door vane and sensor input.- Check the floor data of inverter "MAX FLOOR".- Check the limit switch position.

    F72F72F72F72 Long Creeping ErrorLong Creeping ErrorLong Creeping ErrorLong Creeping Error

    StateStateStateState - Creeping time is over 15 seconds in auto operation

    ReferenceReferenceReferenceReference- Elec.W.diagram : COL 3A, 3B- MCU HHT : 1.IN/OUT >> 1.1 PIO Input >> PIO Input [0]PLUH, PLDH, PLUM, PLDM

    CheckCheckCheckCheckPointPointPointPoint

    - Check the limit switch position.- Check the limit switch signal.- Redo the initialization

  • Hyundai Elevator Co., Ltd. HSVF SYSTEM

    REV.0 2011.12.23TITLE File Name :HSVF Trouble manualHSVF Trouble manualHSVF Trouble manualHSVF Trouble manual

    HSVF SERIESHSVF SERIESHSVF SERIESHSVF SERIESTROUBLESHOOTING MANUALTROUBLESHOOTING MANUALTROUBLESHOOTING MANUALTROUBLESHOOTING MANUAL

    Document Number :

    Rev. Commemts :

    HELCO-C5-003-01 - 16 - A4(210 297 )

    F13F13F13F13 OPB Line disconnection ErrorOPB Line disconnection ErrorOPB Line disconnection ErrorOPB Line disconnection Error

    StateStateStateState- OPB line disconnection error- Possible to move in inspection.

    ReferenceReferenceReferenceReference - MCU HHT : 1.IN/OUT>>1.D CAN Status>>CAN.Car Status

    CheckCheckCheckCheckPointPointPointPoint

    - Check the OPB line and OPB board.- HHT "CAN.Car Status" : 0x000000** (normal)

    : 0x800000** (abnormal)

    F23F23F23F23 OPB bus off ErrorOPB bus off ErrorOPB bus off ErrorOPB bus off Error

    StateStateStateState- MCU commands to stop communication as noise.- Possible to move in inspection.

    ReferenceReferenceReferenceReference - MCU HHT : 1.IN/OUT>>1.D CAN Status>>CAN.Car StatusCheckCheckCheckCheckPointPointPointPoint

    - Check line noise and OPB board.- Check ground condition of machine room.

    F43F43F43F43 PCB WatchDog ErrorPCB WatchDog ErrorPCB WatchDog ErrorPCB WatchDog Error

    StateStateStateState- In stopping condition, F43 set. impossible to move in auto operation.- Possible to move in inspection.

    ReferenceReferenceReferenceReference - NoneCheckCheckCheckCheckPointPointPointPoint - Repair or update the OPB-340 board,

    F63F63F63F63 OPB Communication ErrorOPB Communication ErrorOPB Communication ErrorOPB Communication Error

    StateStateStateState- OPB line is correct, but communication data error occurs.- Possible to move in inspection.

    ReferenceReferenceReferenceReference - MCU HHT : 1.IN/OUT>>1.D CAN Status>>CAN.Car StatusCheckCheckCheckCheckPointPointPointPoint

    - Check communication line and OPB board.- Check OPB board dip switch. (all dip switches must be off)

  • Hyundai Elevator Co., Ltd. HSVF SYSTEM

    REV.0 2011.12.23TITLE File Name :HSVF Trouble manualHSVF Trouble manualHSVF Trouble manualHSVF Trouble manual

    HSVF SERIESHSVF SERIESHSVF SERIESHSVF SERIESTROUBLESHOOTING MANUALTROUBLESHOOTING MANUALTROUBLESHOOTING MANUALTROUBLESHOOTING MANUAL

    Document Number :

    Rev. Commemts :

    HELCO-C5-003-01 - 17 - A4(210 297 )

    F83F83F83F83 OPB Communication Error (Penetration Type)OPB Communication Error (Penetration Type)OPB Communication Error (Penetration Type)OPB Communication Error (Penetration Type)

    StateStateStateState - all communication signal of rear OPB are none

    ReferenceReferenceReferenceReference - MCU Bd HHT : 5. REAR/INFO >> 5.1 Version >> 51f OPB.2

    CheckCheckCheckCheckPointPointPointPoint

    - Check rear OPB ID (DIP Switch 4 on, 3~1 off)- Check rear OPB LD1 (LED flickering) and LD2 (DC 24V)- MCU Bd HHT : 3. SETUP >> 3.2 Device >> 32a OPB2. USE

  • Hyundai Elevator Co., Ltd. HSVF SYSTEM

    REV.0 2011.12.23TITLE File Name :HSVF Trouble manualHSVF Trouble manualHSVF Trouble manualHSVF Trouble manual

    HSVF SERIESHSVF SERIESHSVF SERIESHSVF SERIESTROUBLESHOOTING MANUALTROUBLESHOOTING MANUALTROUBLESHOOTING MANUALTROUBLESHOOTING MANUAL

    Document Number :

    Rev. Commemts :

    HELCO-C5-003-01 - 18 - A4(210 297 )

    F14F14F14F14 Door Error (In running)Door Error (In running)Door Error (In running)Door Error (In running)

    StateStateStateState- Interlock switch or gate switch is not on while elevator running.- F14 impossible to move in any operation.

    ReferenceReferenceReferenceReference- Elec.W.diagram : COL 3A, 3B, 3C, 4A- MCU HHT : 1.IN/OUT >> 1.1 PIO Input >> PIO Input [0] 40, 41

    CheckCheckCheckCheckPointPointPointPoint

    - Check hatch door interlock switch and gate switch.- Check "CT4", "CT5" connectors status of TNP board.- Check "X40", "X41" relays status of TNP board.

    F24F24F24F24 Door Jumper ErrorDoor Jumper ErrorDoor Jumper ErrorDoor Jumper Error

    StateStateStateState - Interlock or gate switch jumper when car door is open fully.

    ReferenceReferenceReferenceReference- Elec.W.diagram : COL 3A, 3B, 3C, 4A- MCU HHT : 1.IN/OUT >> 1.1 PIO Input >> PIO Input [0] 40, 41- MCU HHT : 1.IN/OUT >> 1.3 Car Input >> CarSigIn [0] DOL, DCL

    CheckCheckCheckCheckPointPointPointPoint

    - Check hatch door interlock switch and gate switch.- Check "CT4", "CT5" connectors status of TNP board.- Check "X40", "X41" relays status of TNP board.

    F34F34F34F34 DCL ErrorDCL ErrorDCL ErrorDCL Error

    StateStateStateState - No "DCL" signal input after trying to close 3 times.

    ReferenceReferenceReferenceReference- Elec.W.diagram : COL 6A, 6B, 6C- MCU HHT : 1.IN/OUT >> 1.3 Car Input >> CarSigIn [0] DCL

    CheckCheckCheckCheckPointPointPointPoint

    - Check "DCL" signal and sensor state.- Check door sill and obstacles.- Check "CC13" connector of CCB-7 board.

  • Hyundai Elevator Co., Ltd. HSVF SYSTEM

    REV.0 2011.12.23TITLE File Name :HSVF Trouble manualHSVF Trouble manualHSVF Trouble manualHSVF Trouble manual

    HSVF SERIESHSVF SERIESHSVF SERIESHSVF SERIESTROUBLESHOOTING MANUALTROUBLESHOOTING MANUALTROUBLESHOOTING MANUALTROUBLESHOOTING MANUAL

    Document Number :

    Rev. Commemts :

    HELCO-C5-003-01 - 19 - A4(210 297 )

    F44F44F44F44 Door Open ErrorDoor Open ErrorDoor Open ErrorDoor Open Error

    StateStateStateState

    - After trying to open 3 times, MCU commands to move E/L for next floor.- And if E/L can't open the door again, MCU commands to move E/Lfor lobby.

    - Then F44 error occurs.

    ReferenceReferenceReferenceReference- Elec.W.diagram : COL 6A, 6B, 6C- MCU HHT : 1.IN/OUT >> 1.3 Car Input >> CarSigIn [0] DOL

    CheckCheckCheckCheckPointPointPointPoint

    - Check "DOL" signal and sensor state.- Check door sill and obstacles.- Check "CC13" connector of CCB-7 board.

    F54F54F54F54 Door Close Error (before E/L start to move)Door Close Error (before E/L start to move)Door Close Error (before E/L start to move)Door Close Error (before E/L start to move)

    StateStateStateState- Interlock, gate, DCL signal fault before E/L start to move- F54 cancel calls open, close

    ReferenceReferenceReferenceReference- Elec.W.diagram : COL 3A, 3B, 3C, 4A, 6A, 6B, 6C- MCU HHT : 1.IN/OUT >> 1.1 PIO Input >> PIO Input [0] 40,41- MCU HHT : 1.IN/OUT >> 1.3 Car Input >> CarSigIn [0] DCL

    CheckCheckCheckCheckPointPointPointPoint

    - Check "DCL" signal and sensor state.- Check "CT4", "CT5" connectors status of TNP board.- Check "X40", "X41" relays status of TNP board.

    F64F64F64F64 Door Open Error (Penetration Type)Door Open Error (Penetration Type)Door Open Error (Penetration Type)Door Open Error (Penetration Type)

    StateStateStateState- Front door opened at rear door zone in condition of arrange mode- Rear door opened at front door zone in condition of arrange mode

    ReferenceReferenceReferenceReference

    - Elec.W.diagram : COL 6C- MCU HHT : 1.IN/OUT >> 1.1 PIO Input >> PIO Input [0] FDZ,RDZ- MCU HHT : 1.IN/OUT >> 1.3 Car Input >> CarSigIn [0] DCL- MCU HHT : 1.IN/OUT >> 1.3 Car Input >> CarSigIn [2] RDCL

    CheckCheckCheckCheckPointPointPointPoint

    - Check "DCL,RDCL" signal and sensor state.- Check "FDZ, RDZ" signal and door zone sensor state.- MCU Bd HHT : 3.SETUP >> 3.1 Basic >> 31c Nonstop >> C03,C04FronNonStp

    - MCU Bd HHT : 3.SETUP >> 3.1 Basic >> 31c Nonstop >> C05,C06RearNonStp

  • Hyundai Elevator Co., Ltd. HSVF SYSTEM

    REV.0 2011.12.23TITLE File Name :HSVF Trouble manualHSVF Trouble manualHSVF Trouble manualHSVF Trouble manual

    HSVF SERIESHSVF SERIESHSVF SERIESHSVF SERIESTROUBLESHOOTING MANUALTROUBLESHOOTING MANUALTROUBLESHOOTING MANUALTROUBLESHOOTING MANUAL

    Document Number :

    Rev. Commemts :

    HELCO-C5-003-01 - 20 - A4(210 297 )

    F74F74F74F74 Abnormal Running Error (in a state of door open)Abnormal Running Error (in a state of door open)Abnormal Running Error (in a state of door open)Abnormal Running Error (in a state of door open)

    StateStateStateState- E/L moves to a out of door zone without "FWD,REV" signal.- F74 sub brake activated (RBK off) stop - Impossible to move in any operation

    ReferenceReferenceReferenceReference- Elec.W.diagram : COL 3A, 3B, 4B, 4C- MCU HHT : 1.IN/OUT >> 1.1 PIO Input >> PIO Input [0] RBKI- MCU HHT : 4.MANAGEMENT >> 4.3 FieldTest >> 43b RopeBrkReset

    CheckCheckCheckCheckPointPointPointPoint

    - Check the lining state of brake.- Check the brake spring setting.- Check the gate and hatch interlock switch while E/L is running.- Check "CT51" connector of TNP board. (RBKIN)- Cancel F74 : MCU HHT "43b RopeBrkReset" 0x00

    F84F84F84F84 MC1 Contactor Stuck (After F74 Error)MC1 Contactor Stuck (After F74 Error)MC1 Contactor Stuck (After F74 Error)MC1 Contactor Stuck (After F74 Error)

    StateStateStateState- Though F74 Error happened, "MCI" signal is not off as MC1 contactorstuck.

    - Impossible to move in any operation.

    ReferenceReferenceReferenceReference- Elec.W.diagram : COL2A, COL2B, COL3C, COL4A- MCU Bd HHT : IN/OUT / PIO Input / PIO Input [0] "MCI"- MCU Bd HHT : IN/OUT / PIO Output / PIO Output [0] "MC1"

    CheckCheckCheckCheckPointPointPointPoint

    - Check MC1 contactor condition- Check PIO Output [0] "MC1" signal off- Check PIO Input [0] "MCI" signal off

    F94F94F94F94 Impossible To Move After Door Error (In running)Impossible To Move After Door Error (In running)Impossible To Move After Door Error (In running)Impossible To Move After Door Error (In running)

    StateStateStateState- Interlock switch or gate switch is not on while elevator running.- F94 impossible to move in any operation. (Russian national code)

    ReferenceReferenceReferenceReference

    - Elec.W.diagram : COL 3A, 3B, 3C, 4A- MCU HHT : 1.IN/OUT >> 1.1 PIO Input >> PIO Input [0] 40, 41- MCU HHT : 3.SETUP >> 3.1 Basic >> 31b Field >> B46 BuzzerOption >>

    F94 Enable

    CheckCheckCheckCheckPointPointPointPoint

    - Check hatch door interlock switch and gate switch.- Check "CT4", "CT5" connectors status of TNP board.- Check "X40", "X41" relays status of TNP board.

  • Hyundai Elevator Co., Ltd. HSVF SYSTEM

    REV.0 2011.12.23TITLE File Name :HSVF Trouble manualHSVF Trouble manualHSVF Trouble manualHSVF Trouble manual

    HSVF SERIESHSVF SERIESHSVF SERIESHSVF SERIESTROUBLESHOOTING MANUALTROUBLESHOOTING MANUALTROUBLESHOOTING MANUALTROUBLESHOOTING MANUAL

    Document Number :

    Rev. Commemts :

    HELCO-C5-003-01 - 21 - A4(210 297 )

    F15F15F15F15 Inverter Error (30B)Inverter Error (30B)Inverter Error (30B)Inverter Error (30B)

    StateStateStateState- Abnormal state of inverter (30B off) in spite of MCU output reset signal5 times at 2 second interval.

    - F15 MC1 off impossible to move in any operation.

    ReferenceReferenceReferenceReference- Elec.W.diagram : COL 1A, 1B, 1C- MCU HHT : 1.IN/OUT >> 1.1 PIO Input >> PIO Input [2] 30B

    CheckCheckCheckCheckPointPointPointPoint

    - Connect HHT to inverter and check inverter error.- Check "H9" connector of TNP board.- Check the 3-phase power. (R,S,T)

    F25F25F25F25 Dynamic Braking ErrorDynamic Braking ErrorDynamic Braking ErrorDynamic Braking Error

    StateStateStateState- Despite no command, E/L moves upward or downward

    MCU commands to brake off continuouslyAnd dynamic braking (output "FWD" for 1 second) F25

    ReferenceReferenceReferenceReference- Elec.W.diagram : COL 1A, 1B, 1C, 2A, 2B, 2C- MCU HHT : 1.IN/OUT >> 1.1 PIO Input >> PIO Input [2] ZSP

    CheckCheckCheckCheckPointPointPointPoint

    - Check the lining state of brake.- Check the brake spring setting.- Check the obstacles in brake.- Check the noise in the motor encoder.

    F35F35F35F35 Inverter Setting ErrorInverter Setting ErrorInverter Setting ErrorInverter Setting Error

    StateStateStateState- Despite no command, "RUN" or "BKS" signal of inverter is turned on .- Impossible to move in any operation.

    ReferenceReferenceReferenceReference- Elec.W.diagram : COL 1A, 1B, 1C- MCU HHT : 1.IN/OUT >> 1.1 PIO Input >> PIO Input [2] ZSP,BKS,30B

    CheckCheckCheckCheckPointPointPointPoint

    - Check the all data of inverter.- Check "CN12" of Inverter and "H9" connector of TNP board.

  • Hyundai Elevator Co., Ltd. HSVF SYSTEM

    REV.0 2011.12.23TITLE File Name :HSVF Trouble manualHSVF Trouble manualHSVF Trouble manualHSVF Trouble manual

    HSVF SERIESHSVF SERIESHSVF SERIESHSVF SERIESTROUBLESHOOTING MANUALTROUBLESHOOTING MANUALTROUBLESHOOTING MANUALTROUBLESHOOTING MANUAL

    Document Number :

    Rev. Commemts :

    HELCO-C5-003-01 - 22 - A4(210 297 )

    F45F45F45F45 Inverter Run Signal ErrorInverter Run Signal ErrorInverter Run Signal ErrorInverter Run Signal Error

    StateStateStateState- At the time to start, there is no "RUN" signal of inverter F45 occurs- Impossible to move in any operation.

    ReferenceReferenceReferenceReference- Elec.W.diagram : COL 1A, 1B, 1C- MCU HHT : 1.IN/OUT>>1.2 PIO Output>>PIO Output [0] FWD,REV- MCU HHT : 1.IN/OUT>>1.1 PIO Input>>PIO Input [2] RUN

    CheckCheckCheckCheckPointPointPointPoint

    - Check "H9" connector of TNP board and "CN12" connector of inverter.- Check "FWD,REV" in MCU HHT- Check "F,R" in inverter HHT "MONITOR >> I/O"

    F55F55F55F55 Speed Disagreement ErrorSpeed Disagreement ErrorSpeed Disagreement ErrorSpeed Disagreement Error

    StateStateStateState - Inverter output speed disagreement error while E/L is running.

    ReferenceReferenceReferenceReference - Elec.W.diagram : COL 1A, 1B, 1C

    CheckCheckCheckCheckPointPointPointPoint

    - Check the motor encoder and encoder line noise.- Check the data of inverter HHT.- Check the connection of U,V,W between inverter and motor.- Check the balance between cage and counter weight.- Check another errors of MCU and inverter.

    F65F65F65F65 Inverter ZSP ErrorInverter ZSP ErrorInverter ZSP ErrorInverter ZSP Error

    StateStateStateState- At the time to start, "ZSP" signal is turned on and E/L can't movefor 5 seconds.

    - F65 occurs Possible to move in any operation.

    ReferenceReferenceReferenceReference- Elec.W.diagram : COL 1A, 1B, 1C- MCU HHT : 1.IN/OUT >> 1.1 PIO Input >> PIO Input [2] ZSP

    CheckCheckCheckCheckPointPointPointPoint

    - Check the motor encoder and encoder line.- Check "H9" connector of TNP board and "CN12" connector of inverter.- Check inverter HHT "MONITOR >> I/O".- Check inverter HHT "PROGRAM >> INTERFACE >> Zero Speed Level"

  • Hyundai Elevator Co., Ltd. HSVF SYSTEM

    REV.0 2011.12.23TITLE File Name :HSVF Trouble manualHSVF Trouble manualHSVF Trouble manualHSVF Trouble manual

    HSVF SERIESHSVF SERIESHSVF SERIESHSVF SERIESTROUBLESHOOTING MANUALTROUBLESHOOTING MANUALTROUBLESHOOTING MANUALTROUBLESHOOTING MANUAL

    Document Number :

    Rev. Commemts :

    HELCO-C5-003-01 - 23 - A4(210 297 )

    F75F75F75F75 Inverter Error (In running)Inverter Error (In running)Inverter Error (In running)Inverter Error (In running)

    StateStateStateState - Abnormal state of inverter (30B off) while E/L is running.

    ReferenceReferenceReferenceReference- Elec.W.diagram : COL 1A, 1B, 1C- MCU HHT : 1.IN/OUT >> 1.1 PIO Input >> PIO Input [2] 30B

    CheckCheckCheckCheckPointPointPointPoint

    - Check the inverter HHT "MONITOR >> ERROR"- Check "H9" connector of TNP board and "CN12" connector of inverter.

    F16F16F16F16 Brake Open Error (F26 twice)Brake Open Error (F26 twice)Brake Open Error (F26 twice)Brake Open Error (F26 twice)

    StateStateStateState

    - MCU commands to open brake, but brake can't be operated."BKOP(Brake confirm switch)" isn't activated."RBKIN(sub brake confirm signal)" isn't activated.

    - F26 twice F16 occurs

    ReferenceReferenceReferenceReference- Elec.W.diagram : COL 2A, 2B, 2C, 3A, 3B, 4B, 4C- MCU HHT : 1.IN/OUT >> 1.1 PIO Input >> PIO Input [0] BKOP,RBKI

    CheckCheckCheckCheckPointPointPointPoint

    - Check the brake line power and connection.- Check the "BKOP" switch and connection with MCU HHT.- Check the "CT3B" connector of TNP board.- Check the "RBKIN" line and connection in case of appling sub brake.- Check the "CT51" connector of TNP board.

    F26F26F26F26 Brake Open ErrorBrake Open ErrorBrake Open ErrorBrake Open Error

    StateStateStateState- Same as F16- F26 twice F16 occurs

    ReferenceReferenceReferenceReference- Elec.W.diagram : COL 2A, 2B, 2C, 3A, 3B, 4B, 4C- MCU HHT : 1.IN/OUT >> 1.1 PIO Input >> PIO Input [0] BKOP,RBKI

    CheckCheckCheckCheckPointPointPointPoint - Same as F16

  • Hyundai Elevator Co., Ltd. HSVF SYSTEM

    REV.0 2011.12.23TITLE File Name :HSVF Trouble manualHSVF Trouble manualHSVF Trouble manualHSVF Trouble manual

    HSVF SERIESHSVF SERIESHSVF SERIESHSVF SERIESTROUBLESHOOTING MANUALTROUBLESHOOTING MANUALTROUBLESHOOTING MANUALTROUBLESHOOTING MANUAL

    Document Number :

    Rev. Commemts :

    HELCO-C5-003-01 - 24 - A4(210 297 )

    F36F36F36F36 Brake activation ErrorBrake activation ErrorBrake activation ErrorBrake activation Error

    StateStateStateState- Despite no command, "BKOP(Brake confirm switch)" is activated- F36 occurs buzzer on

    ReferenceReferenceReferenceReference- Elec.W.diagram : COL 3A, 3B- MCU HHT : 1.IN/OUT >> 1.1 PIO Input >> PIO Input [0] BKOP

    CheckCheckCheckCheckPointPointPointPoint

    - Check the "BKOP" switch setting.- Check the obstacles in brake.- Check the "BKOP" line and connection.

    F46F46F46F46 Brake Contactor Stuck ErrorBrake Contactor Stuck ErrorBrake Contactor Stuck ErrorBrake Contactor Stuck Error

    StateStateStateState- In spite of MCU commands to turn brake off, brake contact can't be off.- Impossible to move in any operation.

    ReferenceReferenceReferenceReference- Elec.W.diagram : COL 4A- MCU HHT : 1.IN/OUT >> 1.1 PIO Input >> PIO Input [0] BKB

    CheckCheckCheckCheckPointPointPointPoint

    - Check "BKB" contacts have welded or not- Check brake contactor(BKB) and its connection.- Check "BRB" relay of TNP board.

    F56F56F56F56 Car Brake Input ErrorCar Brake Input ErrorCar Brake Input ErrorCar Brake Input Error

    StateStateStateState - No car brake input in inspection or auto operation.

    ReferenceReferenceReferenceReference- Elec.W.diagram : COL 3A, 3B, 4B- MCU HHT : 1.IN/OUT >> 1.1 PIO Input >> PIO Input [0] RBKI

    CheckCheckCheckCheckPointPointPointPoint

    - Check the car brake state.- Check the "CT51" connector fo TNP board.

    F66F66F66F66 MC2 Contactor Off Error (In running)MC2 Contactor Off Error (In running)MC2 Contactor Off Error (In running)MC2 Contactor Off Error (In running)

    StateStateStateState- No "MC2" contactor input in inspection or auto operation.- Possible to move in any operation.

    ReferenceReferenceReferenceReference- Elec.W.diagram : COL 4A- MCU HHT : 1.IN/OUT >> 1.1 PIO Input >> PIO Input [0] MC2I

    CheckCheckCheckCheckPointPointPointPoint

    - Check the "MCX2" relay of TNP board.- Check the MC2 contactor and its connection.- Check the "CT55" connector of TNP board.

  • Hyundai Elevator Co., Ltd. HSVF SYSTEM

    REV.0 2011.12.23TITLE File Name :HSVF Trouble manualHSVF Trouble manualHSVF Trouble manualHSVF Trouble manual

    HSVF SERIESHSVF SERIESHSVF SERIESHSVF SERIESTROUBLESHOOTING MANUALTROUBLESHOOTING MANUALTROUBLESHOOTING MANUALTROUBLESHOOTING MANUAL

    Document Number :

    Rev. Commemts :

    HELCO-C5-003-01 - 25 - A4(210 297 )

    F76F76F76F76 PDLS ErrorPDLS ErrorPDLS ErrorPDLS Error

    StateStateStateState- "PDLS" signal of CT54 in TNP board is always on.- Impossible to move in any operation.

    ReferenceReferenceReferenceReference- Elec.W.diagram : COL.3B

    - MCU Bd HHT : IN/OUT / PIO Input / PIO Input [1] PDLS"

    CheckCheckCheckCheckPointPointPointPoint - Remove the jumper connector of CT54 in TNP board

    F17F17F17F17 ULS/DLS Off ErrorULS/DLS Off ErrorULS/DLS Off ErrorULS/DLS Off Error

    StateStateStateState- No "ULS/DLS" signal input at the same time- Impossible to move in any operation.

    ReferenceReferenceReferenceReference- Elec.W.diagram : COL 3A, 3B- MCU HHT : 1.IN/OUT >> 1.1 PIO Input >> PIO Input [0] ULS, DLS

    CheckCheckCheckCheckPointPointPointPoint

    - Check the limit switch "ULS, DLS" and its connection.- Check "CT1", "CT2" connector of TNP board.- Check the MCU HHT data "PIO Input[0]>>ULS,DLS".

    F27F27F27F27 PLU/PLD Off ErrorPLU/PLD Off ErrorPLU/PLD Off ErrorPLU/PLD Off Error

    StateStateStateState- No "PLU/PLD" signal input at the same time- Impossible to move in any operation.

    ReferenceReferenceReferenceReference- Elec.W.diagram : COL 3A, 3B, 10A, 10B- MCU HHT : 1.IN/OUT >> 1.1 PIO Input >> PIO Input [0]

    PLUL, PLUH, (PLUM), (PLDM), PLDH, PLDL

    CheckCheckCheckCheckPointPointPointPoint

    - Check the limit switch "PLUL, PLUH, (PLUM), (PLDM), PLDH, PLDL"and its connection.

    - Check "CT1", "CT2" connector of TNP board.

  • Hyundai Elevator Co., Ltd. HSVF SYSTEM

    REV.0 2011.12.23TITLE File Name :HSVF Trouble manualHSVF Trouble manualHSVF Trouble manualHSVF Trouble manual

    HSVF SERIESHSVF SERIESHSVF SERIESHSVF SERIESTROUBLESHOOTING MANUALTROUBLESHOOTING MANUALTROUBLESHOOTING MANUALTROUBLESHOOTING MANUAL

    Document Number :

    Rev. Commemts :

    HELCO-C5-003-01 - 26 - A4(210 297 )

    F37F37F37F37 Door Zone Sensor ErrorDoor Zone Sensor ErrorDoor Zone Sensor ErrorDoor Zone Sensor Error

    StateStateStateStateE/L can't be arrived to door zone for 15 seconds after deceleration.ULA/DLA on, DZ offULA/DLA off, DZ on

    ReferenceReferenceReferenceReference- Elec.W.diagram : COL 4A, 7A- MCU HHT : 1.IN/OUT >> 1.1 PIO Input >> PIO Input [2] "ULA, DZ, DLA"

    CheckCheckCheckCheckPointPointPointPoint

    - Check the door zone sensor input "ULA, DZ, DLA" and its connection.- Check the "T1" harness of TNP board and CCB-7 board.- Check the door zone vane state.- Check the inverter errors and HHT floor data.- Check the "DZ" connection of EPB-100 board. (in case of SSVF7)

    F47F47F47F47 Relevel Landing ErrorRelevel Landing ErrorRelevel Landing ErrorRelevel Landing Error

    StateStateStateState - Out of door zone in door open relevel landing operation

    ReferenceReferenceReferenceReference- Elec.W.diagram : COL 4A- MCU HHT : 1.IN/OUT >> 1.1 PIO Input >> PIO Input [2] "ULA, DLA"

    CheckCheckCheckCheckPointPointPointPoint

    - Check the door zone sensor input "ULA, DZ, DLA" and its connection.- Check the "T1" harness of TNP board and CCB-7 board.- Check the gap between door zone sensors. (135mm)- Check the door zone vane and its length. (300mm)- Check inverter data "PROGRAM>>CONTROL>>RELEVEL RPM".

    F57F57F57F57 ULS/DLS Error (In running)ULS/DLS Error (In running)ULS/DLS Error (In running)ULS/DLS Error (In running)

    StateStateStateState - "ULS" or "DLS" limit switch activated in running.

    ReferenceReferenceReferenceReference- Elec.W.diagram : COL 3A, 3B, 10A, 10B- MCU HHT : 1.IN/OUT >> 1.1 PIO Input >> PIO Input [0] "ULS, DLS"

    CheckCheckCheckCheckPointPointPointPoint

    - Check the limit switch "ULS, DLS", its connection and position.- Check "CT1", "CT2" connector of TNP board.- Check the MCU HHT data "PIO Input[0]>>ULS,DLS".

  • Hyundai Elevator Co., Ltd. HSVF SYSTEM

    REV.0 2011.12.23TITLE File Name :HSVF Trouble manualHSVF Trouble manualHSVF Trouble manualHSVF Trouble manual

    HSVF SERIESHSVF SERIESHSVF SERIESHSVF SERIESTROUBLESHOOTING MANUALTROUBLESHOOTING MANUALTROUBLESHOOTING MANUALTROUBLESHOOTING MANUAL

    Document Number :

    Rev. Commemts :

    HELCO-C5-003-01 - 27 - A4(210 297 )

    F67F67F67F67 PLU/PLD Error (Deceleration Fault)PLU/PLD Error (Deceleration Fault)PLU/PLD Error (Deceleration Fault)PLU/PLD Error (Deceleration Fault)

    StateStateStateState- "PLUL" or "PLDL" limit switch activated in auto operationwithout deceleration.

    ReferenceReferenceReferenceReference- Elec.W.diagram : COL 3A, 3B, 10A, 10B- MCU HHT : 1.IN/OUT >> 1.1 PIO Input >> PIO Input [0] "PLUL, PLDL"

    CheckCheckCheckCheckPointPointPointPoint

    - Check the limit switch "PLUL, PLDL" and its position.- Check "CT1", "CT2" connector of TNP board.- Check the inverter errors and floor data. (MONITOR>>FLOOR DATA)- Do Initializating operation again.

    F77F77F77F77 PLUL/PLDL Error (Floor Confirm Error)PLUL/PLDL Error (Floor Confirm Error)PLUL/PLDL Error (Floor Confirm Error)PLUL/PLDL Error (Floor Confirm Error)

    StateStateStateState- No PLUL switch input at top floor in auto operation.- No PLDL switch input at bottom floor in auto operation.

    ReferenceReferenceReferenceReference- Elec.W.diagram : COL 3A, 3B, 10A, 10B- MCU HHT : 1.IN/OUT >> 1.1 PIO Input >> PIO Input [0] "PLUL, PLDL"

    CheckCheckCheckCheckPointPointPointPoint

    - Check the limit switch "PLUL, PLDL" and its position.- Check "CT1", "CT2" connector of TNP board.- Check the inverter errors and floor data. (MONITOR>>FLOOR DATA)

    F87F87F87F87 Door Sensor Detected Error (UPDOOR + 1BC + E/L for Car)Door Sensor Detected Error (UPDOOR + 1BC + E/L for Car)Door Sensor Detected Error (UPDOOR + 1BC + E/L for Car)Door Sensor Detected Error (UPDOOR + 1BC + E/L for Car)

    StateStateStateState- Detected door sensor "SE, RSE" in auto running.- Impossible to move in any operation.

    ReferenceReferenceReferenceReference- Elec.W.diagram : COL 4A-. MCU Bd HHT : IN/OUT / Car Input / Car Input [0] SE"-. MCU Bd HHT : IN/OUT / Car Input / Car Input [2] RSE"

    CheckCheckCheckCheckPointPointPointPoint - Check door sensor signal and line of "SE, RSE".

  • Hyundai Elevator Co., Ltd. HSVF SYSTEM

    REV.0 2011.12.23TITLE File Name :HSVF Trouble manualHSVF Trouble manualHSVF Trouble manualHSVF Trouble manual

    HSVF SERIESHSVF SERIESHSVF SERIESHSVF SERIESTROUBLESHOOTING MANUALTROUBLESHOOTING MANUALTROUBLESHOOTING MANUALTROUBLESHOOTING MANUAL

    Document Number :

    Rev. Commemts :

    HELCO-C5-003-01 - 28 - A4(210 297 )

    F18F18F18F18 Group Communication ErrorGroup Communication ErrorGroup Communication ErrorGroup Communication Error

    StateStateStateStatecommunication error in ring groupGIO board error in duplex group

    - both , are possible to move in auto single operation.

    ReferenceReferenceReferenceReference

    - Elec.W.diagram : COL 18A, 18B- MCU HHT :

    3.SETUP>>3.1 Basic>>31b Field>>B23 Group Mode1.IN/OUT >> 1.C Group Output >>C24 GOFLAG[7]>>"0x81"

    CheckCheckCheckCheckPointPointPointPoint

    - Check MCU HHT data.- Check the state whether in auto operation or not.- Check GIO board connection of MCU board.- Check GIO board LED state. (refer to "STVF7 ADJUSTMENT MANUAL")

    F28F28F28F28 RMS Communication ErrorRMS Communication ErrorRMS Communication ErrorRMS Communication Error

    StateStateStateState- RMS(Remote Monitoring System) communication error- Possible to move in any operation.

    ReferenceReferenceReferenceReference- Elec.W.diagram : COL 7B- MCU HHT : 3.SETUP>>3.1 Basic>>31b Field>>B22 RMS use>>"Enable"

    CheckCheckCheckCheckPointPointPointPoint

    - Check "H1" connector of MCU board.- Check the power supply of RMS board.

    F38F38F38F38 RNBL ErrorRNBL ErrorRNBL ErrorRNBL Error

    StateStateStateState- "RNBL(Run-By-Limit)" switch is activated while E/L is running.- F38 occurs buzzer on- Possible to move in any operation

    ReferenceReferenceReferenceReference- Elec.W.diagram : COL 3B- MCU HHT : 1.IN/OUT >> 1.1 PIO Input >> PIO Input [1] "RNBL"

    CheckCheckCheckCheckPointPointPointPoint

    - Check the "RNBL" switch connection.- Check the main rope tension.

  • Hyundai Elevator Co., Ltd. HSVF SYSTEM

    REV.0 2011.12.23TITLE File Name :HSVF Trouble manualHSVF Trouble manualHSVF Trouble manualHSVF Trouble manual

    HSVF SERIESHSVF SERIESHSVF SERIESHSVF SERIESTROUBLESHOOTING MANUALTROUBLESHOOTING MANUALTROUBLESHOOTING MANUALTROUBLESHOOTING MANUAL

    Document Number :

    Rev. Commemts :

    HELCO-C5-003-01 - 29 - A4(210 297 )

    F48F48F48F48 Water Over ErrorWater Over ErrorWater Over ErrorWater Over Error

    StateStateStateState - Detected water sensor "WLS" in the pit.(for Lower-Driven MRL)

    ReferenceReferenceReferenceReference- Elec.W.diagram : COL 3B- MCU Bd HHT : IN/OUT /PIO Input /PIO Input [1] "WLS

    CheckCheckCheckCheckPointPointPointPoint - Check the water sensor "WLS" signal and its lines.

    F58F58F58F58 LS Board Communication ErrorLS Board Communication ErrorLS Board Communication ErrorLS Board Communication Error

    StateStateStateState- LS board communication error in case of "LXVF7, SSVF7"- Possible to move in any operation

    ReferenceReferenceReferenceReference- Elec.W.diagram : COL 7A- MCU HHT : 3.SETUP>>3.1 Basic>>31a General>>A20 Load Sensor

    CheckCheckCheckCheckPointPointPointPoint

    - Check the LS board connection.- Check the CAN communication line between OPB and LS board.- Check the "JU1" jumper pin of OPB board. (short)

    F68F68F68F68 Hall Communication ErrorHall Communication ErrorHall Communication ErrorHall Communication Error

    StateStateStateState- Hall-CAN board communication error- Possible to move in any operation

    ReferenceReferenceReferenceReference- Elec.W.diagram : COL 8A, 11A, 11B- MCU HHT : 2.ERROR>>2.3Hall Error>> HallErr.1, HallErr.2

    CheckCheckCheckCheckPointPointPointPoint

    - Check MCU HHT : 2.ERROR>>2.3Hall Error>> HallErr.1, HallErr.2- Check the communication line.- Check the Hall-CAN board state and dip switch adjustment.(refer to "STVF7 ADJUSTMENT MANUAL)

  • Hyundai Elevator Co., Ltd. HSVF SYSTEM

    REV.0 2011.12.23TITLE File Name :HSVF Trouble manualHSVF Trouble manualHSVF Trouble manualHSVF Trouble manual

    HSVF SERIESHSVF SERIESHSVF SERIESHSVF SERIESTROUBLESHOOTING MANUALTROUBLESHOOTING MANUALTROUBLESHOOTING MANUALTROUBLESHOOTING MANUAL

    Document Number :

    Rev. Commemts :

    HELCO-C5-003-01 - 30 - A4(210 297 )

    F78F78F78F78 MC2 Contactor Error (At starting)MC2 Contactor Error (At starting)MC2 Contactor Error (At starting)MC2 Contactor Error (At starting)

    StateStateStateState- No "MC2" contactor input at starting in case of SSVF7- Impossible to move in any operation

    ReferenceReferenceReferenceReference- Elec.W.diagram : COL 1C, 3C, 4A- MCU HHT : 1.IN/OUT >> 1.1 PIO Input >> PIO Input [0] "MC2I"- MCU HHT : 1.IN/OUT >> 1.2 PIO Output >> PIO Output [0] "MC2"

    CheckCheckCheckCheckPointPointPointPoint

    - Check the "MCX2" relay of TNP board.- Check "MC2" contactor connection.- Check "CT55" connector of TNP board.

    F59F59F59F59 LS Setting ErrorLS Setting ErrorLS Setting ErrorLS Setting Error

    StateStateStateState- No LS setting in case of LXVF7 and SSVF7- Possible to move in any operation

    ReferenceReferenceReferenceReference- Elec.W.diagram : COL 7A- MCU HHT : 3.SETUP>>3.1 Basic>>31a General>>A20 Load Sensor

    CheckCheckCheckCheckPointPointPointPoint

    - Do LS board setting according to "STVF7 ADJUSTMENT MANUAL"HHT : 20a LS Use "Enable" 20c Sensing Data 9000~10000 (check LS sensor position) load 0% in cageHHT : 20b Load Setting>>0% "settable"(check in door zone and inspection switch in Machine room)HHT : 0% >> "YES" enter "waiting" 0% setting end (buzzer)load 50% in cageHHT : 50% >> "settable" "YES" enter "waiting" 50% setting end (buzzer twice)

  • Hyundai Elevator Co., Ltd. HSVF SYSTEM

    REV.0 2011.12.23TITLE File Name :HSVF Trouble manualHSVF Trouble manualHSVF Trouble manualHSVF Trouble manual

    HSVF SERIESHSVF SERIESHSVF SERIESHSVF SERIESTROUBLESHOOTING MANUALTROUBLESHOOTING MANUALTROUBLESHOOTING MANUALTROUBLESHOOTING MANUAL

    Document Number :

    Rev. Commemts :

    HELCO-C5-003-01 - 31 - A4(210 297 )

    F69F69F69F69 RTC ErrorRTC ErrorRTC ErrorRTC Error

    StateStateStateState - Time Setting fault or time chip fault of MCU board

    ReferenceReferenceReferenceReference- MCU Bd HHT : 3. SETUP >> 3.3 Time & Date >> 33a Time set- MCU Bd HHT : 3. SETUP >> 3.3 Time & Date >> 33b Date set

    CheckCheckCheckCheckPointPointPointPoint

    - Check the mercury cell voltage (DC 3V).- Set the time and date with HHT.

  • Hyundai Elevator Co., Ltd. HSVF SYSTEM

    REV.0 2011.12.23TITLE File Name :HSVF Trouble manualHSVF Trouble manualHSVF Trouble manualHSVF Trouble manual

    HSVF SERIESHSVF SERIESHSVF SERIESHSVF SERIESTROUBLESHOOTING MANUALTROUBLESHOOTING MANUALTROUBLESHOOTING MANUALTROUBLESHOOTING MANUAL

    Document Number :

    Rev. Commemts :

    HELCO-C5-003-01 - 32 - A4(210 297 )