HARTING M8 / M12 Circular Connectors · mechanical engineering, ... the automobile industry and...
Transcript of HARTING M8 / M12 Circular Connectors · mechanical engineering, ... the automobile industry and...
HARTINGM8 / M12 Circular Connectors
Transforming customer wishes into concrete solutions
The HARTING Technology Group is skilled in the fields of electrical, electronic and optical connection, transmission and networking, as well as in manufacturing, mechatronics and software creation. The Group uses these skills to develop customized solutions and products such as connectors for energy and data transmission applications including, for example, mechanical engineering, rail technology, wind energy plants, factory automation and the telecommunications sector. In addition, HARTING also produces electro-magnetic components for the automobile industry and offers solutions in the field of Enclosures and Shop Systems.The HARTING Group currently comprises 37 subsidiary companies and worldwide distributors employing a total of more than 3.800 staff.
H A R T I N G w o r l d w i d e
HARTING RepresentativesHARTING Subsidiary company
We aspire to top performance.Connectors ensure functionality. As core elements of electrical and optical wiring, connection and infrastructure technologies, they are essential in enabling the modular construction of devices, machines and systems across a very wide range of industrial applications. Their reliability is a crucial factor guaranteeing smooth functioning in the manufacturing area, in telecommunications, applications in medical technology – in fact, connectors are at work in virtually every conceivable application area. Thanks to the consistent further development of our technologies, customers enjoy investment security and benefit from durable, long term functionality.
Always at hand, wherever our customers may be.Increasing industrialization is creating growing markets characterized by widely diverging demands and requirements. The search for perfection, increasingly efficient processes and reliable technologies is a common factor in all sectors across the globe.HARTING is providing these technologies – in Europe, America and Asia. The HARTING professionals at our international subsidiaries engage in close, partnership based interaction with our customers, right from the very early product development phases, in order to realize customer demands and requirements in the best possible manner.
Our people on location form the interface to the centrally coordinated development and production departments. In this way, our customers can rely on consistently high, superior product quality – worldwide.
Our claim: Pushing Performance.HARTING provides more than optimally attuned components. In order to serve our customers with the best possible solutions, HARTING is able to contribute a great deal more and play a closely integrative role in the value creation process.From ready assembled cables through to control racks or ready-to-go control desks: Our aim is to generate the maximum benefits for our customers – without compromise!
Quality creates reliability – and warrants trust.The HARTING brand stands for superior quality and reliability – worldwide. The standards we set are the result of consistent, stringent quality management that is subject to regular certifications and audits.EN ISO 9001, the EU Eco-Audit and ISO 14001:2004 are key elements here. We take a proactive stance to new requirements, which is why HARTING ranks among the first companies worldwide to have obtained the new IRIS quality certificate for rail vehicles.
H A R T I N G w o r l d w i d e
HARTING technology creates added value for customers.Technologies by HARTING are at work worldwide. HARTING’s presence stands for smoothly functioning systems, powered by intelligent connectors, smart infrastructure solutions and mature network systems. In the course of many years of close, trust-based cooperation with its customers, the HARTING Technology Group has advanced to one of the worldwide leading specialists for connector technology. Extending beyond the basic functionalities demanded, we offer individual customers specific and innovative solutions. These tailored solutions deliver sustained effects, provide investment security and enable customers to achieve strong added value.
Opting for HARTING opens up an innovative, complex world of concepts and ideas.In order to develop connectivity and network solutions serving an exceptionally wide range of connector applications and task scopes in a professional and cost optimized manner, HARTING not only commands the full array of conventional tools and basic technologies. Over and beyond these capabilities, HARTING is constantly harnessing and refining its broad base of knowledge and experience to create new solutions that ensure continuity at the same time. In securing this know-how lead, HARTING draws on a wealth of sources from both in-house research and the world of applications alike.Salient examples of these sources of innovative knowledge include microstructure technologies, 3D design and construction technology, as well as high temperature
or ultrahigh frequency applications that are finding use in telecommunications or automation networks, in the automotive industry, or in industrial sensor and actuator applications, RFID and wireless technologies, in addition to packaging and housing made of plastics, aluminum or stainless steel.
HARTING solutions extend across technology boundaries.Drawing on the comprehensive resources of the group’s technology pool, HARTING devises practical solutions for its customers. Whether this involves industrial networks for manufacturing automation, or hybrid interface solutions for wireless telecommunication infrastructures, 3D circuit carriers with microstructures, or cable assemblies for high-temperature applications in the automotive industry – HARTING technologies offer far more than components, and represent mature, comprehensive solutions attuned to individual customer requirements and wishes. The range covers ready-to-use cable configurations, completely assembled backplanes and board system carriers, as well as fully wired and tested control panels. In order to ensure the future proof design of RF- and EMC-compatible interface solutions, the central HARTING laboratory (certified to EN 45001) provides simulation tools, as well as experimental, testing and diagnostics facilities all the way through to scanning electron microscopes. In the selection of materials and processes, lifecycle and environmental aspects play a key role, in addition to product and process capability considerations.
HARTING knowledge is practical know-how generating synergy effects.HARTING commands decades of experience with regard to the applications conditions of connectors in telecommunications, computer and network technologies and medical technologies, as well as industrial automation technologies, such as the mechanical engineering and plant engineering areas, in addition to the power generation industry or the transportation sector. HARTING is highly conversant with the specific application areas in all of these technology fields.
The key focus is on applications in every solution approach. In this context, uncompromising, superior quality is our hallmark. Every new solution found will invariably flow back into the HARTING technology pool, thereby enriching our resources. And every new solution we go on to create will draw on this wealth of resources in order to optimize each and every individual solution. In this way, HARTING is synergy in action.
Embedded Computing Systems Broadcast and Entertainment M
edical
A
utomat
ion
Mac
hine
ry &
Rob
otics
Tra
nsportation Solar Energy Wind Energy Power Generation and Distribution
Backplanes
Industrial Connectors Actuator Systems
Cable
Assem
blie
s
Tools
sof ware
Asse
mbl
y line
s
3D Micropackages Advanced Vending Systems Applications-
PCB Technologies
InformationTechnologies
ProductionTechnologies
Metal TreatmentTechnologies
Micro StructureTechnologies
NetworkTechnologies
Simulation
InterconnectTechnologies
Mechatronic
Competence in sofware development
Competence in system integration
The HARTING eCatalogue is an electronic catalogue with a part configuration and 3D components library.
Here you can choose a connector according to your requirements. Afterwards you are able to send your inquiry directly to a HARTING sales partner.
The drawings to every single part are available in PDF-format.
The parts are downloadable in 2D-format (DXF) and 3D-format (IGES, STEP).
The 3D-models can be viewed with a VRML-viewer.
You can find the HARTING eCatalogue at www.HARTING.com.
Product selection
Product overview Product combination
© HARTING Electronics GmbH, Espelkamp – All rights reserved, including those of the translation.
Product samples: Fast-track delivery to your desk, free of charge
The new free express sample service in the HARTING eCatalogue allows customers to order samples immediately, easily and completely free of charge. A broad selection from the device connectivity product portfolio is now available. If a product is unavailable, the system offers alternative products with similar features that can be requested at a mouse click.
The free samples are shipped within 24 hours at no cost to you. This service enables tremendous flexibility, especially in the design phase of projects.
Product configuration
General information
It is the customer’s responsibility to check whether the components illustrated in this catalogue also comply with different regulations from those stated in special fields of applications.
We reserve the right to modify designs or substance of content in order to improve quality, keep pace with technological advancement or meet particular requirements in production.
No part of this catalogue may be reproduced in any form (print, photocopy, microfilm or any other process) or processed, duplicated or distributed by means of electronic systems without the prior written consent of HARTING Electronics GmbH, Espelkamp. We are bound by the German version only.
HARTING eCatalogue
01
02
03
04
05
06
07
Be
M8 / M12 Circular connectors
Directory Chapter
General information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 01
M8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 02
M12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 03
har-speed M12 data connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 04
7/8“ HARAX® . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 05
HARAX® panel feed-through . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 06
INOX – Solutions for extreme demands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 07
List of part numbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Be
Addresses
Notes
0101
011. General information
1.1 Circular connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 01.02
1.2 Special series features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 01.03
1.3 Termination expertise . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 01.04
1.4 Specifications, approvals, mating faces and pin assignments . . . . . . . . . . . . . 01.05
M8 / M12 Circular connectors
Directory Page
0102
01
Circular Connectors
Standardized circular connectors with M8, M12 and 7/8“ thread are in widespread use in the installation of machines and systems. HARTING offers a portfolio of field-assembly angled and straight M8, M12 and 7/8” connectors which are attuned to meet all relevant automation requirements. The housings are available as plastic and as metal variant. In addition to the standard circular connectors for sensors/actuators, HARTING is offering standardized circular connectors such as the M12 variants to meet the special requirements of communication technology (Ethernet, Ethernet/IP, PROFINET, Profibus, Devicenet and CAN).
The HARTING product range comprises connectors, ready-to-use patch cables and corresponding accessories.The easy-to-handle HARAX® quick connection technology is available for the in situ assembly of M8 and M12 connectors and
does not require the use of special tools. The portfolio of circular connectors is rounded off by the har-speed M12 connector family. The har-speed connectors are optimized for machinery and system applications with high bandwidth as well as for the IP67 infrastructure. HARTING’s comprehensive and user-friendly circular connector range enables cost-effective and quick realization of all wiring and communication tasks in automation projects.
APPLIANCE INTEGRATION:In order to support the implementation of appliances with degree of protection IP65 / IP67, HARTING offers panel feed-through devices with ready-to use patch cables and female contact modules for direct mounting on PCBs.
0103
01
ASSEMBLED SYSTEM CABLES:HARTING offers a comprehensive range of ready-to-use M8/M12 system cables for the quick wiring of sensors and actuators. HARTING also offers ready-to-use and tested system cables for special Ethernet communication such as PROFINET and Ethernet/IP.HARTING also provides custom patch cables which are also available as overmoulded versions. The range of solutions comprises shielded and non-shielded cables with diverse structures, as required in drag chain applications, for example.
M12 FEMALE SOCKETS FOR PCB MOUNTING:Straight and angled contact inserts are available for direct soldering on PCBs. HARTING has developed special shielded contact inserts category 5 to ISO/IEC 11801 for Ethernet technology which meet the stringent requirements for railway applications.
QUICK CONNECTION WITH HARAX®:The HARTING HARAX® quick connection technology is an ideal solution for the in situ assembly of M8/M12 connectors.Users only have to strip the cable insulation, insert the conductors, and screw the connector together in order to produce a gas-proof and vibration resistant connection.HARAX® is a universal technology deployed in diverse connector series to wire data, signal and power lines and represents the current standard connection for Fieldbus and Fast Ethernet.
Special series features
0104
01
Termination expertise
WIRE TERmINATION ExPERTIsE
1. IdC INsuLATION dIsPLACEmENT TERmINALsIDC (insulation displacement contact) technology facilitates the simple and safe termination of solid and flexible conductors. With IDC technology, a blade cuts through the wire insulation and produces an elastic termination in a single pass. This gas-proof connection provides maximum safety even for the lowest currents and voltages. HARAX® Fast termination technology is a special feature offered by HARTING which combines the insulation displacement connector with a wire guide element for conveniently producing on-site field installation without special tools. Technical requirements for IDC technology are standardized in IEC 60 352-3.
2. CRImP TERmINALsGas-proof and the miniaturized contact technology are synonymous with crimp technology. The flexible conductor is inserted into the crimp contact and is retained by controlled deformation. This technology is similar to a cold welding process and provides maximum aging resistance and mechanical resistance to shock and vibration. Crimp machines facilitate the efficient, streamlined production of system cable assemblies, and crimp technology can also be deployed for field assemblies using the corresponding hand crimp tools. The technical requirements for crimp technology are standardized in IEC 60 352-2.
PCB TERmINATION ExPERTIsE
7. THT sOLdERING TECHNOLOGy
Proven over decades, standard soldering technologies deliver maximum stability and process reliability.
The soldering pins of the connectors are inserted into the through-plated PCB holes and can then be soldered simultaneously with other components in a wave soldering process.
8. smC sOLdERING TECHNOLOGy
The connector is inserted into through-plated PCB holes similar to standard component assembly for processing with SMC (Surface Mount Compatible) soldering technology. Insertion of these SMT components can be automated by means of Pick & Place assembly in preparation for a reflow soldering process together with the surface-mounted component.
This connection technology is characterized by high mechanical strength and is facilitated by a design that is specially adapted to the reflow soldering process (high-temperature materials).
9. smT sOLdERING TECHNOLOGy
By contrast to through-plated assembly, the SMT (Surface Mounted Technology) connectors are soldered directly onto the PCB surface by means of soldering pads.
This process represents a uniform connection technology for PCB assembly and offers the advantage of SMT connectors that do not require separate wave soldering.
0105
01
Specifications, approvals, mating faces and pin assignments
SpecificationsIEC 60 352-4, IEC 61076-2-104, IEC 61076-2-101, IEC 61076-2-109, ,
M8 circular connectors, mating face acc. to IEC 61076-2-104
Male, 3 poles Male, 4 poles Female, 3 poles Female, 4 poles
M12 circular connectors, mating face acc. to IEC 61076-2-101
A-coding
Male, 4 poles Male, 5 poles Male, 8 poles Female, 4 poles Female, 5 poles Female, 8 poles
B-coding
Male, 5 poles Female, 5 poles
D-coding
Male, 4 poles Female, 4 poles
X-coding, mating face acc. to IEC 61076-2-109
Male, 8 poles Female, 8 poles
7/8“
Male, 5 poles Female, 5 poles
0106
01
Pin assignment
X-coding, mating face acc. to IEC 61076-2-109
Adapter M12/RJ45
8 poles pin assignment
Signals Pin assignment Cable
1/10Gbit 10/100 Mbit RJ45 M12
D-codedM12
X-coded 4-wire 568A 568B
BI_DA+ TxData+ 1 1 1 yellow white/green white/orange
BI_DA- TxData- 2 3 2 orange green orange
BI_DB+ RxData+ 3 2 3 white white/orange white/green
BI_DC+ - 4 - 8 blue blue
BI_DC- - 5 - 7 white/blue white/blue
BI_DB- RxData- 6 4 4 blue orange green
BI_DD+ - 7 - 5 white/brown white/brown
BI_DD- - 8 - 6 brown brown
4 poles pin assignment
10/100 Mbit RJ45 M12
D-coded 4-wire
TxData+ 1 1 yellow
TxData- 2 3 orange
RxData+ 3 2 white
RxData- 6 4 blue
0107
01M12 RJ45
1 1
2 2
3 3
4 6
5 7
6 8
7 5
8 4
Pin assignment
Adapter M12/RJ45
8 poles pin assignment
Gender changer
4 poles 8 poles
0108
01
Notes
0201
02
M8 Circular connectors
Directory Page
2. M8
2.1 A-coded – Solutions for actor and sensor applications
o Technical characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 02.02
Cableconnectors • HARAX ® M8-XS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 02.05 • HARAX ® M8-S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 02.06 • Systemcables. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 02.08
o Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 02.12
0202
02
Technical characteristics M8 HARAX®
Specifications IEC 60 352-4
Approval
M8 HARAX® cable connector
Type M8 HARAX ® M8-XS HARAX ® M8-S
General data
Conductor cross section 0.1 - 0.14 mm² AWG 27-26
0.14 - 0.34 mm² AWG 26-22
Diameter of individual strands ≥0.05mm ≥0.1mm
Conductor insulation material PVC / PP / TPE PVC / PP / TPE
Conductor diameter 0.6 - 1.0 mm 1.0 - 1.6 mm
Cable diameter 1.9 - 2.5 mm 2.5 - 3.5 mm 2.5 - 5.1 mm
Temperature range -40 °C … +85 °C -40 °C … +85 °C
Temperature during connection -5 °C … +50 °C -5 °C … +50 °C
Degree of protection IP67 IP67
Mating cycles 100 100
Recommended tightening torque / Hexagonal wrench 0.4 Nm / SW 9 0.4 Nm / SW 9
Electrical characteristics
Rated current 2 A 4 A
Rated voltage 32 V 32 V
Rated impulse voltage 1.5 kV 1.5 kV
Contact resistance 10mΩ 10mΩ
Insulation resistance 108Ω 108Ω
Pollution degree 3 3
Overvoltage category 3 3
Isolation group 1 1
Materials
Contact material Copper alloy Copper alloy
Contact plating Gold Gold
Contact carrier material PA PA
Housing material PA, zinc die-cast PA, zinc die-cast
Mating face
A-coding Mating face
acc. to IEC 61 076-2-101
Further information and data sheets see www.HARTING.com
0203
02
Á
À
Further information and data sheets see www.HARTING.com
M8 HARAX® cable connector
Technical characteristics – System cablesM8 Circular connectors, without PE
Rated voltage max. 60 V AC / DC
Rated current / contact max. 4 A
Locking Screw locking M8x1, self securing
Recommended torque 0.4 Nm
Temperature range -25 °C … +85 °C (dependant on connected conductor)
Degree of protection IP67
Number of wires / wire gauge 3 x 0.25 mm²
Conductor insulation PP (bn, bu, bk)
Arrangement of insulated strands 32 x 0.1 mm
Sheath PUR (UL, CSA)
Outer diameter appr. 4.2 - 5.5 mm
Bending radius 10 x outer diameter
Temperature range (working and storage) -5 °C … + 80 °C
Technical characteristics M8Current carrying capacity The current carrying capacity is limited by maximum temperature of materials for inserts and contacts
including terminals. The current capacity-curve is valid for continuous, not interruptet current-loaded contacts of connectors when simultaneous power on all contacts is given, without exceeding the maximum temperature.
Control and test procedures according to DIN IEC 60 512-5.
Rat
ed c
urre
nt [A
]
Ambient temperature [oC]
M8-S, 4 poles 1 = Wire gauge 0.25 mm² 2 = Wire gauge 0.34 mm²
Rat
ed c
urre
nt [A
]
Ambient temperature [oC]
M8-XS, 3 poles 1 = Wire gauge 0.1 mm² M8-S, 3 poles 2 = Wire gauge 0.14 mm²
0204
02
Notes
0205
02
21 02 159 1305
Further information and data sheets see www.HARTING.com
M8 HARAX ®
Identification Part No. Drawing Dimensions in mm
HARAX ® M8-XS
Male straight version, 3 poles for 0.1 - 0.14 mm²
•Actorandsensorapplications
•Unshieldedversions
•HARAX ® rapid termination
•Overmouldedsystemcablesinvariouslengths
•Robustdesign,quickassembly
Applications / Advantages
Mating face
A-coding Mating face
acc. to IEC 61 076-2-101
0206
02
21 02 151 1305
21 02 151 1405
Further information and data sheets see www.HARTING.com
M8 HARAX ®
Identification Part No. Drawing Dimensions in mm
Male straight version, 3 poles for 0.14 - 0.34 mm²
Male straight version, 4 poles for 0.14 - 0.34 mm²
Mating face
A-coding Mating face
acc. to IEC 61 076-2-101
HARAX ® M8-S
View mating side: 3 poles, male
View mating side: 4 poles, male
0207
02
21 02 151 2305
21 02 151 2405
Further information and data sheets see www.HARTING.com
M8 HARAX ®
Identification Part No. Drawing Dimensions in mm
Female straight version, 3 poles for 0.14 - 0.34 mm²
Female straight version, 4 poles for 0.14 - 0.34 mm²
Mating face
A-coding Mating face
acc. to IEC 61 076-2-101
HARAX ® M8-S
0208
02
M8 System cables
Technical characteristicsM8 Circular connector, without PERated voltage max. 60 V AC/DC
Rated current/contact max. 4 A
Locking Screw locking M8x1, self securing
Recommended torque 0.4 Nm
Temperature range -25 °C … +85 °C (dependant on connected conductor)
Degree of protection IP67
Number of wires / wire gauge 3 x 0.25 mm²
Conductor insulation PP (br, bl, sw)
Arrangement of insulated strands 32 x 0.1 mm
Sheath PUR (UL, CSA)
Outer diameter appr. 4.2 - 5.5 mm
Bending radius 10 x outer diameter
Temperature range (working and storage) -5 °C … + 80 °C
Mating face
A-coding Mating face
acc. to IEC 61 076-2-101
0209
02
Mating face
A-coding Mating face
acc. to IEC 61 076-2-101
M8 System cables
Overview system cables M8Male M8 straight
Female M8 angled
Number of contacts
Cable material PUR
Cable material PUR
Fem
ale
M8
angl
ed
0.3 m 21 02 454 5301 xxx0.6 m 21 02 454 5302 xxx1.0 m 21 02 454 5303 xxx1.5 m 21 02 454 5304 xxx2.0 m 21 02 454 5305 xxx
0.3 m 21 02 454 7301 with LED xxx0.6 m 21 02 454 7302 with LED xxx1.0 m 21 02 454 7303 with LED xxx1.5 m 21 02 454 7304 with LED xxx2.0 m 21 02 454 7305 with LED xxx
Ope
n en
d
xxx 1.5 m 21 02 554 4301xxx 3.0 m 21 02 554 4302xxx 5.0 m 21 02 554 4303xxx 7.5 m 21 02 554 4304xxx 10.0 m 21 02 554 4305
xxx 1.5 m 21 02 554 7301 with LEDxxx 3.0 m 21 02 554 7302 with LEDxxx 5.0 m 21 02 554 7303 with LEDxxx 7.5 m 21 02 554 7304 with LEDxxx 10.0 m 21 02 554 7305 with LED
0210
02
21 02 454 530121 02 454 530221 02 454 530321 02 454 530421 02 454 5305
21 02 454 730121 02 454 730221 02 454 730321 02 454 730421 02 454 7305
Identification PartNo. Drawing Dimensionsinmm
M8 Circular connectors Female angled, male straight
Length: 0.3 m0.6 m1.0 m1.5 m2.0 m
M8 Circular connectors Female angled, with LED Male straight
Length: 0.3 m0.6 m1.0 m1.5 m2.0 m
M8 System cables
Schematic diagram
View mating side
Schematic diagram
View mating side
Cable sleeve Cable imprint
Cable sleeve Cable imprint
Further information and data sheets see www.HARTING.com
Mating face
A-coding Mating face
acc. to IEC 61 076-2-101
0211
02
21 02 554 430121 02 554 430221 02 554 430321 02 554 430421 02 554 4305
21 02 554 730121 02 554 730221 02 554 730321 02 554 730421 02 554 7305
M8 System cables
Identification PartNo. Drawing Dimensionsinmm
M8 Circular connectors Female angled pre-assembled on one end
Length: 1.5 m3.0 m5.0 m7.5 m
10.0 m
Length: 1.5 m3.0 m5.0 m7.5 m
10.0 m
M8 Circular connectors Female angled, with LED pre-assembled on one end
Cable sleeve Cable imprint
Schematic diagram View mating side
Schematic diagram View mating side
Cable sleeve Cable imprint
Further information and data sheets see www.HARTING.com
Mating face
A-coding Mating face
acc. to IEC 61 076-2-101
0212
02
21 01 010 201621 01 010 200821 01 010 2005
21 01 010 2013
09 99 000 0380
M8 Accessories
Identification Part No. Drawing Dimensions in mm
for 1.9 - 2.5 mm cable Ø for 2.5 - 3.5 mm cable Ø for 4.2 - 5.4 mm cable Ø
Seal M8
for 2.5 - 3.2 mm cable Øfor 3.2 - 4.0 mm cable Øfor 4.0 - 5.1 mm cable Ø
Set of seals for HARAX ® M8-S
M8 dynamometric screwdriver
Tightening torque 0.4 Nm
Further information and data sheets see www.HARTING.com
SW 9
0301
03
M12 Circular connectors
Directory Page
3. M12
3.1 A-coded – Solutions for actor and sensor applications
o Technical characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 03.04
Cableconnectors • HARAX ® M12-S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 03.08 • HARAX ® M12 angled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 03.10 • HARAX ® M12-L unshielded . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 03.12 • HARAX ® M12-L shielded . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 03.14 • M12Crimp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 03.16 • System cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 03.20
Device connectors • Panelfeed-through . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 03.26 • PCBadapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 03.32
o Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 03.36
3.2 B-coded – Solutions for Profibus applications
o Technical characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 03.40
Cable connectors • HARAX ® M12 L shielded . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 03.42 • M12 Crimp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 03.44 • Systemcables. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 03.46
Deviceconnectors • Panel feed-through . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 03.50 • PCBadapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 03.56
o Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 03.60
3.3 D-coded – Solutions for Ethernet applications
o Technical characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 03.64
Cableconnectors • HARAX ® M12 L shielded . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 03.66 • M12Crimp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 03.68 • M12 preLink® . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 03.71 • Systemcables. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 03.73
Deviceconnectors • Panel feed-through . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 03.78 • PCBadapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 03.86
o Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 03.91
0302
03
Notes
0303
03
M12 Circular connectors
Directory Page
3.1 A-coded – Solutions for actor and sensor applications
o Technical characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 03.04
Cableconnectors
• HARAX ® M12-S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 03.08
• HARAX ® M12 angled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 03.10
• HARAX ® M12-L unshielded . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 03.12
• HARAX ® M12-L shielded . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 03.14
• M12Crimp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 03.16
• Systemcables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 03.20
Device connectors
• Panelfeed-through . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 03.26
• PCB adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 03.32
o Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 03.36
0304
03Technical characteristics M12 – A-coding
Specifications IEC 60 352-4
Approval
M12 A-coding
Type M12 A-coded HARAX ® M12-S HARAX ® M12 angled
HARAX ® M12 L 3 poles, 4 poles
General data
Conductor cross section 0.14 - 0.34 mm²AWG 26-22
0.25 - 0.5 mm²AWG 24/7-20
0.34 - 0.75 mm²AWG 22-18
Diameter of individual strands ≥0.1mm ≥0.1mm ≥0.1mm
Conductor insulation material PVC / PP / TPE PVC PVC
Conductor diameter 1.0 - 1.6 mm 1.2 - 1.6 mm 1.6 - 2.0 mm 2.0 - 2.6 mm
Cable diameter 2.9 - 4.0 mm 4.0 - 5.1 mm 4 - 5.1 mm 6 - 8 mm
Temperature range -40 °C … +85 °C -40 °C … +85 °C -40 °C … +85 °C
Temperature during connection -5° C … +50 °C -5 °C … +50 °C -5 °C … +50 °C
Degree of protection IP67 IP67 IP65 / IP67
Mating cycles 100 100 100
Tightening torque connector / hexagonal wrench 0.6 Nm / SW 13 0.6 Nm / SW 13 0.6 Nm / SW 17
Electrical characteristics
Rated current 4 A 4 A 6 A
Rated voltage 32 V 32 V 50 V
Rated impulse voltage 1.5 kV 1.5 kV 1.5 kV
Contact resistance 10mΩ 10mΩ 10mΩ
Insulation resistance 108Ω 108Ω 108Ω
Pollution degree 3 3 3
Overvoltage category 3 3 3
Isolation group 1 1 1
Materials
Contact material Brass Brass Brass
Contact plating Gold Gold Gold
Contact carrier material PA reinforced PA PA unreinforced
Housing material PA reinforced PA PA unreinforced
Mating face
A-coding Mating face
acc. to IEC 61 076-2-101
Further information and data sheets see www.HARTING.com
0305
03Technical characteristics M12 – A-coding
Specifications IEC 60 352-4
Approval
M12 A-coding
Type M12 A-coded HARAX ® M12-L 5 poles
HARAX ® M12 L shielded M12 Crimp
General data
Conductor cross section 0.34 - 0.5 mm² AWG 22-20
0.14 - 0.34 mm² AWG 26-22
0.14 - 0.75 mm² AWG 26-18
Diameter of individual strands ≥0.1mm ≥0.1mm X
Conductor insulation material PVC PVC X
Conductor diameter 1.2 - 2.0 mm 1.2 - 1.6 mm 2.0 - 2.3 mm
Cable diameter 6 - 8 mm 4.5 - 8.8 mm 4.5 - 8.8 mm
Temperature range -40 °C … +85 °C -40 °C … +85 °C -40 °C … +85 °C
Temperature during connection -5 °C … +50 °C -5 °C … +50 °C -5 °C … +50 °C
Degree of protection IP65 / IP67 IP65 / IP67 IP67
Mating cycles 100 100 500
Tightening torque connector / hexagonal wrench 0.6 Nm / SW 17 0.6 Nm / SW 17 0.5 Nm / SW 17
Electrical characteristics
Rated current 4 A 4 A 4 A
Rated voltage 50 V 50 V 250 V
Rated impulse voltage 1.5 kV 1.5 kV 1.5 kV
Contact resistance 10mΩ 10mΩ 10mΩ
Insulation resistance 108Ω 108Ω 108Ω
Pollution degree 3 3 3
Overvoltage category 3 3 3
Isolation group 1 1 1
Materials
Contact material Brass Brass Brass
Contact plating Gold Gold Gold
Contact carrier material PA unreinforced PA unreinforced PA
Housing material PA unreinforced PA unreinforced PA
Mating face
A-coding Mating face
acc. to IEC 61 076-2-101
Further information and data sheets see www.HARTING.com
0306
03
Technical characteristics M12 – A-codingCurrent carrying capacity The current carrying capacity is limited by maximum temperature of materials for inserts and contacts
including terminals. The current capacity-curve is valid for continuous, not interruptet current-loaded contacts of connectors when simultaneous power on all contacts is given, without exceeding the maximum temperature.
Control and test procedures according to DIN IEC 60 512-5.
Rat
ed c
urre
nt [A
]
Ambient temperature [oC]
M12-S, 4 poles 1 = Wire gauge 0.25 mm² 2 = Wire gauge 0.34 mm²
Rat
ed c
urre
nt [A
]
Ambient temperature [oC]
M12, 4 poles, 1 = Wire gauge 0.25 mm² angled 2 = Wire gauge 0.5 mm²
Rat
ed c
urre
nt [A
]
Ambient temperature [oC]
M12-L 1 = Wire gauge 0.34 mm² 3 poles, 4 poles 2 = Wire gauge 0.75 mm²
Rat
ed c
urre
nt [A
]
Ambient temperature [oC]
M12L, 5 poles 1 = Wire gauge 0.25 mm² 2 = Wire gauge 0.34 mm²
Rat
ed c
urre
nt [A
]
Ambient temperature [oC]
M12, Crimp 1 = Wire gauge 0.34 mm² / 0.5 mm²
Further information and data sheets see www.HARTING.com
M12 A-coding
0307
03
Technical characteristics M12 – A-coding, PCB adapter
Further information and data sheets see www.HARTING.com
M12 A-coding
Rat
ed c
urre
nt [A
]
Rat
ed c
urre
nt [A
]
Ambient temperature [oC] Ambient temperature [oC]
M12, A-coding, straight, male, 4 poles Wire gauge 0.5 mm²
M12, A-coding, straight, female, 4 poles Wire gauge 0.75 mm²
Rat
ed c
urre
nt [A
]
Rat
ed c
urre
nt [A
]
Ambient temperature [oC] Ambient temperature [oC]
M12, A-coding, straight, female, 5 poles Wire gauge 0.5 mm²
M12, A-coding, straight, male, 5 poles Wire gauge 0.5 mm²
0308
03
21 03 111 1405
21 03 112 1405
Further information and data sheets see www.HARTING.com
M12 HARAX ® A-coded
Identification Part No. Drawing Dimensions in mm
HARAX ® M12-S
Male straight version 4 poles, 0.14 - 0.34 mm²
Male straight version 4 poles, 0.25 - 0.5 mm²
•Actorandsensorapplications
•Shieldedandunshieldedversions
•Availablewithcrimpresp.HARAX ® rapid termination, or as overmoulded system cable in various lengths
•Robustdesign,quickassembly
Applications / Advantages
Mating face
A-coding Mating face
acc. to IEC 61 076-2-101
0309
03
21 03 111 2405
21 03 112 2405
Further information and data sheets see www.HARTING.com
M12 HARAX ® A-coded
Identification Part No. Drawing Dimensions in mm
HARAX ® M12-S
Female straight version 4 poles, 0.14 - 0.34 mm²
Female straight version 4 poles, 0.25 - 0.5 mm²
Mating face
A-coding Mating face
acc. to IEC 61 076-2-101
0310
03
21 01 140 5081
Further information and data sheets see www.HARTING.com
M12 HARAX ® A-coded
Identification Part No. Drawing Dimensions in mm
Male angled version 4 poles
Mating face
A-coding Mating face
acc. to IEC 61 076-2-101
HARAX ® M12
0311
03
21 01 140 5091
Further information and data sheets see www.HARTING.com
M12 HARAX ® A-coded
Identification Part No. Drawing Dimensions in mm
Female angled version 4 poles
Mating face
A-coding Mating face
acc. to IEC 61 076-2-101
HARAX ® M12
0312
03
21 03 212 1400
21 03 212 1306
21 03 212 1305
21 03 212 1407
21 03 272 1505
Further information and data sheets see www.HARTING.com
M12 HARAX ® A-coded
Identification Part No. Drawing Dimensions in mm
HARAX ® M12-L, unshielded
Mating face
A-coding Mating face
acc. to IEC 61 076-2-101
Male 3 poles, A-coding, with pre-leading contact (assignment 3, 4, 5)
3 poles, A-coding (assignment 1, 3, 4)
4 poles, A-coding (assignment 1, 2, 3, 4)
4 poles, A-coding, to 2.6 mm core diameter (assignment 1, 2, 3, 4)
0.34 - 0.75 mm² AWG 22 - 18 Cable diameter: 6 - 8 mm
Male 5 poles, A-coding 0.34 - 0.5 mm² AWG 22 - 20 Cable diameter: 6 - 8 mm
HARAX ® M12-L, unshielded
0313
03
21 03 212 2400
21 03 212 2306
21 03 212 2305
21 03 212 2407
21 03 272 2505
Further information and data sheets see www.HARTING.com
M12 HARAX ® A-coded
Identification Part No. Drawing Dimensions in mm
HARAX ® M12-L, unshielded
Mating face
A-coding Mating face
acc. to IEC 61 076-2-101
Female 3 poles, A-coding (assignment 3, 4, 5)
3 poles, A-coding (assignment 1, 3, 4)
4 poles, A-coding (assignment 1, 2, 3, 4)
4 poles, A-coding, to 2.6 mm core diameter (assignment 1, 2, 3, 4)
0.34 - 0.75 mm² AWG 22 - 18 Cable diameter: 6 - 8 mm
Female 5 poles, A-coding 0.34 - 0.5 mm² AWG 22 - 20 Cable diameter: 6 - 8 mm
HARAX ® M12-L, unshielded
0314
03
21 03 221 1405
21 03 121 1801
Further information and data sheets see www.HARTING.com
M12 HARAX ® A-coded
Identification Part No. Drawing Dimensions in mm
Mating face
A-coding Mating face
acc. to IEC 61 076-2-101
Male 4 poles, A-coding 0.14 - 0.34 mm² / AWG 26 - 22
HARAX ® M12-L, shielded
Male with IDC termination, 8 poles 0.14 - 0.34 mm² / AWG 26 - 22
M12 Circular connector
0315
03
21 03 221 2405
21 03 121 2801
Further information and data sheets see www.HARTING.com
M12 HARAX ® A-coded
Identification Part No. Drawing Dimensions in mm
Mating face
A-coding Mating face
acc. to IEC 61 076-2-101
Female 4 poles, A-coding 0.14 - 0.34 mm² / AWG 26 - 22
HARAX ® M12-L, shielded
Female with IDC termination technology, 8 poles 0.14 - 0.34 mm² / AWG 26 - 22
M12 Circular connectors
0316
03
21 03 812 1405
21 03 812 1505*
21 03 821 1505*
Further information and data sheets see www.HARTING.com* UL approval is in preparation
M12 Crimp A-coded
Identification Part No. Drawing Dimensions in mm
Mating face
A-coding Mating face
acc. to IEC 61 076-2-101
Male 4 poles, A-coding
Male 5 poles, A-coding
Male 5 poles, A-coding Cable diameter: 4.5 - 8.8 mm
M12 Crimp
M12 Crimp
M12 Crimp Slim design
0317
03
21 03 822 3505*
Further information and data sheets see www.HARTING.com* UL approval is in preparation
M12 Crimp A-coded
Identification Part No. Drawing Dimensions in mm
M12 Crimp, angled
Mating face
A-coding Mating face
acc. to IEC 61 076-2-101
Male 5 poles, A-coding
0318
03
21 03 812 2405
21 03 812 2505*
M12 Crimp A-coded
Identification Part No. Drawing Dimensions in mm
M12 Crimp
Mating face
A-coding Mating face
acc. to IEC 61 076-2-101
Female 4 poles, A-coding
Female 5 poles, A-coding
M12 Crimp
Further information and data sheets see www.HARTING.com* UL approval is in preparation
0319
03
21 03 822 4505*
M12 Crimp A-coded
Identification Part No. Drawing Dimensions in mm
M12 Crimp, angled
Mating face
A-coding Mating face
acc. to IEC 61 076-2-101
Female 5 poles, A-coding
Further information and data sheets see www.HARTING.com* UL approval is in preparation
0320
03
M12 System cables, A-coded
Technical characteristicsM12 Circular connectors, without PE
Rated voltage max. 250 V AC/DC, max. 30 V DC (with LED)
Rated current / contact max. 4 A
Locking Screw locking M12x1, self securing
Recommended torque 0.6 Nm
Temperature range -25 °C … +85 °C (dependant on connected conductor)
Degree of protection IP67
Number of wires / wire gauge 4 x 0.34 mm²
Conductor insulation PP (bn, wh, bu, bk)
Arrangement of insulated strands 42 x 0.1 mm
Sheath PUR (UL, CSA)
Outer diameter appr. 4.7 mm
Bending radius 10 x outer diameter
Temperature range (working and storage) -25 °C … + 80 °C
Further information and data sheets see www.HARTING.com
Mating face
A-coding Mating face
acc. to IEC 61 076-2-101
0321
03
M12 System cables, A-codedMating face
A-coding Mating face
acc. to IEC 61 076-2-101
Overview system cables M12Male M12 A-coding, straight Female M12 A-coding, angled
Number of contacts
Cable material: PUR Cable material: PUR
Fem
ale
M12
stra
ight
0.3 m 21 03 415 2401 xxx0.6 m 21 03 415 2402 xxx1.0 m 21 03 415 2403 xxx1.5 m 21 03 415 2404 xxx2.0 m 21 03 415 2405 xxx
angl
ed
0.3 m 21 03 415 5401 xxx0.6 m 21 03 415 5402 xxx1.0 m 21 03 415 5403 xxx1.5 m 21 03 415 5404 xxx2.0 m 21 03 415 5405 xxx
0.3 m 21 03 415 7401 with LED xxx0.6 m 21 03 415 7402 with LED xxx1.0 m 21 03 415 7403 with LED xxx1.5 m 21 03 415 7404 with LED xxx2.0 m 21 03 415 7405 with LED xxx
Ope
n en
d
xxx 1.5 m 21 03 515 4401xxx 3.0 m 21 03 515 4402xxx 5.0 m 21 03 515 4403xxx 7.5 m 21 03 515 4404xxx 10.0 m 21 03 515 4405
xxx 1.5 m 21 03 515 7401 with LEDxxx 3.0 m 21 03 515 7402 with LEDxxx 5.0 m 21 03 515 7403 with LEDxxx 7.5 m 21 03 515 7404 with LEDxxx 10.0 m 21 03 515 7405 with LED
M12
cab
le s
et
for i
ndiv
idua
l ass
embl
y in
cl. H
AR
AX
® M
12 M
ale
xxx 1.5 m 21 83 515 4401xxx 3.0 m 21 83 515 4402xxx 5.0 m 21 83 515 4403xxx 7.5 m 21 83 515 4404xxx 10.0 m 21 83 515 4405
xxx 1.5 m 21 83 515 7401 with LEDxxx 3.0 m 21 83 515 7402 with LEDxxx 5.0 m 21 83 515 7403 with LEDxxx 7.5 m 21 83 515 7404 with LEDxxx 10.0 m 21 83 515 7405 with LED
0322
03
M12 System cables, A-codedMating face
A-coding Mating face
acc. to IEC 61 076-2-101
Overview system cables M12Male M12 A-coding, straight
Number of contacts
Cable material: PUR
Ope
n en
d
1.0 m 21 03 514 18012.0 m 21 03 514 18035.0 m 21 03 514 1805
0323
03
21 03 415 240121 03 415 240221 03 415 240321 03 415 240421 03 415 2405
21 03 415 540121 03 415 540221 03 415 540321 03 415 540421 03 415 5405
21 03 415 740121 03 415 740221 03 415 740321 03 415 740421 03 415 7405
Identification PartNo. Drawing Dimensionsinmm
M12 Circular connectors Female straight, male straight
Length: 0.3 m0.6 m1.0 m1.5 m2.0 m
M12 Circular connectors Female angled, male straight
Length: 0.3 m0.6 m1.0 m1.5 m2.0 m
M12 Circular connectors Female angled, with LED, Male straight
Length: 0.3 m0.6 m1.0 m1.5 m2.0 m
Cable sleeve Cable imprint
Cable sleeve Cable imprint
Cable sleeve Cable imprint
Schematic diagram
View mating side
Schematic diagram
View mating side
Schematic diagramView mating side
M12 System cables, A-coded
Further information and data sheets see www.HARTING.com
Mating face
A-coding Mating face
acc. to IEC 61 076-2-101
0324
03
21 03 515 440121 03 515 440221 03 515 440321 03 515 440421 03 515 4405
21 03 515 740121 03 515 740221 03 515 740321 03 515 740421 03 515 7405
Identification PartNo. Drawing Dimensionsinmm
M12 Circular connectors Female angled pre-assembled on one end
Length: 1.5 m3.0 m5.0 m7.5 m
10.0 m
Length: 1.5 m3.0 m5.0 m7.5 m
10.0 m
M12 Circular connectors Female angled, with LED pre-assembled on one end
Schematic diagram
View mating side
Schematic diagram
View mating side
Cable sleeve Cable imprint
Cable sleeve Cable imprint
M12 System cables, A-coded
Further information and data sheets see www.HARTING.com
Mating face
A-coding Mating face
acc. to IEC 61 076-2-101
0325
03
21 83 515 440121 83 515 440221 83 515 440321 83 515 440421 83 515 4405
21 83 515 740121 83 515 740221 83 515 740321 83 515 740421 83 515 7405
21 03 514 1801
21 03 514 1803
21 03 514 1805
Identification PartNo. Drawing Dimensionsinmm
M12 System cables, A-coded
Length: 1.5 m3.0 m5.0 m7.5 m
10.0 m
Length: 1.5 m3.0 m5.0 m7.5 m
10.0 m
Length: 1.0 m
3.0 m
5.0 m
HARAX ® M12 Cable set without LED Delivery range: M12 connector with
individually adaptable cable and HARAX® M12-S
HARAX ® M12 Cable set with LED Delivery range: M12 connector with
individually adaptable cable and HARAX® M12-S
1 x M12 Circular connectors, straight
pre-assembled on one end, 8 poles
Cable sleeve Cable imprint
Cable sleeve Cable imprint
Further information and data sheets see www.HARTING.com
HARAX ® M12-S (21 03 111 1405)
HARAX ® M12-S (21 03 111 1405)
Mating face
A-coding Mating face
acc. to IEC 61 076-2-101
0326
03
21 03 321 1425
Further information and data sheets see www.HARTING.com
M12 Panel feed-through HARAX ® A-coded
Identification Part No. Drawing Dimensions in mm
HARAX ® Panel feed-through
Male 4 poles, A-coding 0.14 - 0.34 mm² / AWG 26 - 22
•Actorandsensorapplications
•Forpanelfeed-throughorPCB,straightversioninIP20orIP67,withorwithoutassembledpigtail
•Available with crimp resp. HARAX® rapid termination
•Quickandeasyassembly
Applications / Advantages
Mating face
A-coding Mating face
acc. to IEC 61 076-2-101
Panel thickness min. 2.5 mm max. 4.5 mm
0327
03
21 03 321 2425
Further information and data sheets see www.HARTING.com
M12 Panel feed-through HARAX ® A-coded
Identification Part No. Drawing Dimensions in mm
HARAX ® Panel feed-through
Female 4 poles, A-coding 0.14 - 0.34 mm² / AWG 26 - 22
Mating face
A-coding Mating face
acc. to IEC 61 076-2-101
Panel thickness min. 2.5 mm max. 4.5 mm
0328
03
21 03 822 1425
21 03 822 1525*
M12 Panel feed-through Crimp
Male 4 poles, A-coding
Male 5 poles, A-coding
M12 Panel feed-through Crimp
M12 Panel feed-through Crimp A-coded
Identification Part No. Drawing Dimensions in mm
Mating face
A-coding Mating face
acc. to IEC 61 076-2-101
Further information and data sheets see www.HARTING.com* UL approval is in preparation
Panel thickness min. 2.5 mm max. 4.5 mm
Panel thickness min. 2.5 mm max. 4.5 mm
0329
03
21 03 822 2425
21 03 822 2525*
M12 Panel feed-through Crimp
Female 4 poles, A-coding
Female 5 poles, A-coding
M12 Panel feed-through Crimp
M12 Panel feed-through Crimp A-coded
Identification Part No. Drawing Dimensions in mm
Mating face
A-coding Mating face
acc. to IEC 61 076-2-101
Further information and data sheets see www.HARTING.com* UL approval is in preparation
Panel thickness min. 2.5 mm max. 4.5 mm
Panel thickness min. 2.5 mm max. 4.5 mm
0330
03
21 03 311 1402
21 03 311 1501
M12 Panel feed-through
Male A-coding, 50 cm conductors, 0.5 mm², 4 poles
Male A-coding, 50 cm conductors, 0.5 mm², 5 poles
M12 Panel feed-through
Further information and data sheets see www.HARTING.com
M12 Panel feed-through A-coded
Identification Part No. Drawing Dimensions in mm
Mating face
A-coding Mating face
acc. to IEC 61 076-2-101
Panel thickness min. 2.0 mm max. 5.0 mm
Panel thickness min. 2.0 mm max. 5.0 mm
0331
03
21 03 311 2400
21 03 311 2501
M12 Panel feed-through
Female A-coding, 50 cm conductors, 0.5 mm², 4 poles
Female A-coding, 50 cm conductors, 0.5 mm², 5 poles
M12 Panel feed-through
Further information and data sheets see www.HARTING.com
M12 Panel feed-through A-coded
Identification Part No. Drawing Dimensions in mm
Mating face
A-coding Mating face
acc. to IEC 61 076-2-101
Panel thickness min. 2.0 mm max. 5.0 mm
Panel thickness min. 2.0 mm max. 5.0 mm
0332
03
21 03 321 1410
21 03 321 1420
21 03 321 1510
21 03 321 1520
Further information and data sheets see www.HARTING.com
M12 PCB adapter A-coded
Identification Part No. Drawing Dimensions in mm
Mating face
A-coding Mating face
acc. to IEC 61 076-2-101
M12 PCB adapterMale, A-coding, straight
M12 PCB adapterMale, A-coding, straight
4 poles, IP20
4 poles, IP67
5 poles, IP20
5 poles, IP67
Technical characteristics: M12 PCB adapterDegree of protection IP20, IP67
(mated and locked)
Rated current max. 4 A (dependant on PCB layout)
Rated voltage 50 V
Mating cycles max. 100
Limiting temperature -40 °C … +85 °C
Temperature during connection -5 °C … +50 °C
Termination PIH
Contact material Copper alloy
Contact plating (mating side) Au over Ni
Insulator material PA
0333
03
21 03 321 6410
21 03 321 6420*
21 03 321 6510
21 03 321 6520
21 03 311 2801
M12 PCB adapter A-coded
Identification Part No. Drawing Dimensions in mm
Mating face
A-coding Mating face
acc. to IEC 61 076-2-101
M12 PCB adapterFemale, A-coding, straight
M12 PCB adapterFemale, A-coding, straight
M12 PCB adapterFemale, A-coding, straight
4 poles, IP20
4 poles, IP67
5 poles, IP20
5 poles, IP67
8 poles, IP67
Further information and data sheets see www.HARTING.com* UL approval is in preparation
0334
03
21 03 321 1518*
21 03 321 1818*
21 03 301 1000
21 03 301 1001
M12 PCB adapter, shielded
Male 5 poles, A-coding
8 poles, A-coding
for rear mounting
for front mounting
Housing
M12 PCB adapter shielded A-coded
Identification Part No. Drawing Dimensions in mm
Mating face
A-coding Mating face
acc. to IEC 61 076-2-101
Further information and data sheets see www.HARTING.com* UL approval is in preparation
0335
03
21 03 321 2518*
21 03 321 2818*
21 03 301 2000
21 03 301 2001
M12 PCB adapter, shielded
Female 5 poles, A-coding
8 poles, A-coding
for rear mounting
for front mounting
Housing
M12 PCB adapter shielded A-coded
Identification Part No. Drawing Dimensions in mm
Mating face
A-coding Mating face
acc. to IEC 61 076-2-101
Further information and data sheets see www.HARTING.com* UL approval is in preparation
0336
03
09 99 000 0501
21 03 321 9400
09 99 000 0531
09 67 000 3576 09 67 000 8576 09 67 000 5576
09 67 000 347609 67 000 8476 09 67 000 5476
09 99 000 0382
09 99 000 0646
09 99 000 0384
21 03 030 1400
Identification PartNo. Drawing
M12 Accessories
Crimping toolfor M12 Crimp
Accessories M12 Crimp
Locator
D-Sub single contacts (500 mating cycles)
turned male contacts AWG 22 - 18 / 0.33 - 0.82 mm² AWG 24 - 20 / 0.25 - 0.52 mm² AWG 26 - 22 / 0.13 - 0.33 mm²
turned female contacts AWG 22 - 18 / 0.33 - 0.82 mm² AWG 24 - 20 / 0.25 - 0.52 mm² AWG 26 - 22 / 0.13 - 0.33 mm²
aAWG 22 - 18 1.34AWG 24 - 20 1.13AWG 26 - 22 0.88
M12 dynamometric screwdriver
Tightening torque 0.6 Nm
for M12-S
for M12 Slim design
for M12-L
Further information and data sheets see www.HARTING.com
SW 13
SW 15
SW 17
HARTING M12 T-Coupler
D-Sub contacts
Part number AWG Tool settings
09 67 000 3x76
18 6
20 6
22 5
09 67 000 8x76 20, 22, 24 6
09 67 000 5x76 22, 24, 26 6
M12-male moving load
A-coding
0337
03
21 01 000 0018
21 01 010 201121 01 010 2001
21 01 010 201521 01 010 2007
21 01 010 2017
21 01 000 0003
Accessories M12
Lock nut
M12 Accessories
Identification Part No. Drawing Dimensions in mm
Seal M12-Sfor 2.9 - 4.0 mm cable Øfor 4 - 5.1 mm cable Ø
Seal M12-L unshieldedfor 4.7 - 6 mm cable Øfor 6 - 8 mm cable Ø
Set of seals M12-L shieldedfor 4.5 - 5.4 mm cable Øfor 5.4 - 7.2 mm cable Øfor 7.2 - 8.8 mm cable Ø
Cap M12for IP65 / IP67Seals material VitonPlastic cap for female
Further information and data sheets see www.HARTING.com
0338
03
21 01 000 0033
21 01 000 0038
21 01 000 0030
21 01 000 0031
M12 Accessories
Identification Part No. Drawing Dimensions in mm
Cap metal M12for IP65 / IP67 M12 metal cap for male side with cord
Cap metal M12for IP65 / IP67 M12 metal cap for male side with cable clip
Cap metal M12for IP65 / IP67 M12 metal cap for female side with cord
Cap metal M12for IP65 / IP67 M12 metal cap for female side with cable clip
Further information and data sheets see www.HARTING.com
0339
03
M12 Circular connectors
Directory Page
3.2 B-coded – Solutions for Profibus applications
o Technical characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 03.40
Cable connectors
• HARAX ® M12 L shielded . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 03.42
• M12Crimp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 03.44
• Systemcables. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 03.46
Deviceconnectors
• Panel feed-through . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 03.50
• PCBadapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 03.56
o Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 03.60
0340
03Type M12 B-coded HARAX ® M12 L
shielded M12 Crimp
General data
Conductor cross section 0.25 - 0.34 mm² AWG 24-22
0.13 - 0.75 mm² AWG 26-18
Diameter of individual strands ≥0.1mm X
Conductor insulation material PVC, Zell-PE X
Conductor diameter 2 - 2.6 mm 2.0 - 2.3 mm
Cable diameter 7.0 - 8.8 mm 4 poles: 4.5 - 8.8 mm5 poles: 4.5 - 8.8 mm
Temperature range -40 °C … +85 °C -40 °C … +85 °C
Temperature during connection -5 °C … +50 °C -5 °C … +50 °C
Degree of protection IP65 / IP67 IP67
Mating cycles 100 500
Tightening torque connector / hexagonal wrench 0.6 Nm / SW 17 0.5 Nm / SW 17
Electrical characteristics
Rated current 4 A 4 A
Rated voltage 32 V 250 V
Rated impulse voltage 1.5 kV 1.5 kV
Contact resistance 10mΩ 10mΩ
Insulation resistance 108Ω 108Ω
Pollution degree 3 3
Overvoltage category 3 3
Isolation group 1 1
Materials
Contact material Brass Brass
Contact plating Gold Gold
Contact carrier material PA unreinforced PA
Housing material PA unreinforced PA
Technical characteristics M12 – B-coding
Specifications IEC 60 352-4
Approval
M12 B-codingMating face
B-coding Mating face
acc. to IEC 61 076-2-101
Further information and data sheets see www.HARTING.com
0341
03
Technical characteristics M12 – B-codingCurrent carrying capacity The current carrying capacity is limited by maximum temperature of materials for inserts and contacts
including terminals. The current capacity-curve is valid for continuous, not interruptet current-loaded contacts of connectors when simultaneous power on all contacts is given, without exceeding the maximum temperature.
Control and test procedures according to DIN IEC 60 512-5.
Rat
ed c
urre
nt [A
]
Ambient temperature [oC]
M12-L 1 = Wire gauge 0.34 mm² 3 poles, 4 poles 2 = Wire gauge 0.75 mm²
Rat
ed c
urre
nt [A
]
Ambient temperature [oC]
M12, Crimp 1 = Wire gauge 0.34 mm² / 0.5 mm²
Further information and data sheets see www.HARTING.com
M12 B-coding
0342
03
21 03 241 1301
Further information and data sheets see www.HARTING.com
M12 HARAX ® B-coded
Identification Part No. Drawing Dimensions in mm
HARAX ® M12-L, shielded
Male 2 poles, B-coding 0.25 - 0.34 mm² / AWG 24 - 22
•B-codingforfieldbussystemse.g.Profibus,DeviceNetorCANopen
•Availablewithcrimpresp.HARAX ® rapid termination, or as overmoulded system cable in various lengths
•Shieldingbythehood
•Easyhandling,quickassembly
Applications / Advantages
Mating face
B-coding Mating face
acc. to IEC 61 076-2-101
0343
03
21 03 241 2301
Further information and data sheets see www.HARTING.com
M12 HARAX ® B-coded
Identification Part No. Drawing Dimensions in mm
HARAX ® M12-L, shielded
Female 2 poles, B-coding 0.25 - 0.34 mm² / AWG 24 - 22
Mating face
B-coding Mating face
acc. to IEC 61 076-2-101
0344
03
21 03 841 1505
Further information and data sheets see www.HARTING.com
M12 Crimp B-coded
Identification Part No. Drawing Dimensions in mm
M12 Crimp
Mating face
B-coding Mating face
acc. to IEC 61 076-2-101
Male 5 poles, B-coding
0345
03
21 03 841 2505
Further information and data sheets see www.HARTING.com
M12 Crimp B-coded
Identification Part No. Drawing Dimensions in mm
M12 Crimp
Mating face
B-coding Mating face
acc. to IEC 61 076-2-101
Female 5 poles, B-coding
0346
03Rated voltage max. 125 V AC/ DC
Rated current / contact max. 4 A
Locking Screw locking M12 x 1 mm, self securing
Recommended tightening torque 0.6 Nm
Temperature range (male) °C -25 °C … +85 °C, dependant on connected conductor
Degree of protection IP67
Number of wires / wire gauge 1 x 2 x diameter 0.64 mm
Conductor insulation PUR (rd, gn)
Arrangement of insulated strands 19 x 0.13 mm
Sheath PUR (UL/CSA)
Outer diameter appr. 7.8 mm
Bending radius bewegt 15 x outer diameter
Temperature range °C (applicate with fixed cable) -30 °C … + 80 °C
Technical characteristics
Further information and data sheets see www.HARTING.com
M12 System cables, B-codingMating face
B-coding Mating face
acc. to IEC 61 076-2-101
0347
03Overview system cables M12
M12 System cables, B-codingMating face
B-coding Mating face
acc. to IEC 61 076-2-101
Male M12 B-codingstraight angled
Number of contacts
Cable material: PUR Cable material: PUR
Fem
ale
M12 st
raig
ht
0.3 m 21 03 449 4301 xxx 0.6 m 21 03 449 4302 xxx 1.0 m 21 03 449 4303 xxx 1.5 m 21 03 449 4304 xxx 2.0 m 21 03 449 4305 xxx
angl
ed
xxx 0.3 m 21 03 449 6301xxx 0.6 m 21 03 449 6302xxx 1.0 m 21 03 449 6303xxx 1.5 m 21 03 449 6304xxx 2.0 m 21 03 449 6305
Ope
n en
d
1.5 m 21 03 549 1301 1.5 m 21 03 549 3301 3.0 m 21 03 549 1302 3.0 m 21 03 549 3302 5.0 m 21 03 549 1303 5.0 m 21 03 549 3303 7.5 m 21 03 549 1304 7.5 m 21 03 549 330410.0 m 21 03 549 1305 10.0 m 21 03 549 3305
Female M12 B-codingstraight angled
Number of contacts
Cable material: PUR Cable material: PUR
Ope
n en
d
1.5 m 21 03 549 2301 1.5 m 21 03 549 4301 3.0 m 21 03 549 2302 3.0 m 21 03 549 4302 5.0 m 21 03 549 2303 5.0 m 21 03 549 4303 7.5 m 21 03 549 2304 7.5 m 21 03 549 430410.0 m 21 03 549 2305 10.0 m 21 03 549 4305
0348
03
21 03 549 130121 03 549 130221 03 549 130321 03 549 130421 03 549 1305
21 03 549 330121 03 549 330221 03 549 330321 03 549 330421 03 549 3305
Schirm
rot 4
grün2
Schirm
rot 4
grün2
M12 System cables, B-coding
M12 Circular connectors, Male, straight pre-assembled on one end,
useable as trailing cable
Length: 1.5 m3.0 m5.0 m7.5 m
10.0 m
Length: 1.5 m3.0 m5.0 m7.5 m
10.0 m
M12 Circular connectors, Male, angled pre-assembled on one end,
useable as trailing cable
Identification PartNo. Darstellung
Schematic diagram
Schematic diagramgreenred
shielding
greenred
shielding
Further information and data sheets see www.HARTING.com
Mating face
B-coding Mating face
acc. to IEC 61 076-2-101
0349
03
21 03 449 430121 03 449 430221 03 449 430321 03 449 430421 03 449 4305
21 03 449 630121 03 449 630221 03 449 630321 03 449 630421 03 449 6305
21 03 549 430121 03 549 430221 03 549 430321 03 549 430421 03 549 4305
21 03 549 230121 03 549 230221 03 549 230321 03 549 230421 03 549 2305
Schirm
rot 4
grün2
4
2
4
2
Schirm
Schirm
rot 4
grün2
4
2
4
2
Schirm
Identification PartNo. Darstellung
M12 Circular connectors, Male, straight Female, straight pre-assembled on one end,
useable as trailing cable
Length: 0.3 m0.6 m1.0 m1.5 m2.0 m
Length: 0.3 m0.6 m1.0 m1.5 m2.0 m
M12 Circular connectors, Male, angled Female, angled pre-assembled on one end,
useable as trailing cable
M12 Circular connectors, Female, straight pre-assembled on one end,
useable as trailing cable
Length: 1.5 m3.0 m5.0 m7.5 m
10.0 m
Schematic diagram
Schematic diagram
Schematic diagram
Schematic diagram
M12 Circular connectors, Female, angled pre-assembled on one end,
useable as trailing cable
Length: 1.5 m3.0 m5.0 m7.5 m
10.0 m
M12 System cables, B-coding
shielding
shielding
greenred
shielding
greenred
shielding
Further information and data sheets see www.HARTING.com
Mating face
B-coding Mating face
acc. to IEC 61 076-2-101
0350
03
21 03 341 1425
Further information and data sheets see www.HARTING.com
M12 Panel feed-through HARAX ® B-coded
Identification Part No. Drawing Dimensions in mm
HARAX ® Panel feed-through
Male 2 poles and shielding, B-coding 0.25 - 0.34 mm² / AWG 24 - 22
Cable diameter: 7 - 8.8 mm
•B-codingforfieldbussystemse.g.Profibus,DeviceNetorCANopen
•For panel feed-through or PCB, straight version in IP20 or IP67, with or without assembled pigtail
•Available with crimp resp. HARAX® rapid termination
•Quickandeasyassembly
Applications / Advantages
Mating face
B-coding Mating face
acc. to IEC 61 076-2-101
Panel thickness min. 2.5 mm max. 4.5 mm
0351
03
21 03 341 2425
Further information and data sheets see www.HARTING.com
M12 Panel feed-through HARAX ® B-coded
Identification Part No. Drawing Dimensions in mm
HARAX ® Panel feed-through
Female 2 poles and shielding, B-coding 0.25 - 0.34 mm² / AWG 24 - 22
Cable diameter: 7 - 8.8 mm
Mating face
B-coding Mating face
acc. to IEC 61 076-2-101
Panel thickness min. 2.5 mm max. 4.5 mm
0352
03
21 03 841 1525
M12 Panel feed-through Crimp
Male 5 poles, B-coding
Further information and data sheets see www.HARTING.com
M12 Panel feed-through Crimp B-coded
Identification Part No. Drawing Dimensions in mm
Mating face
B-coding Mating face
acc. to IEC 61 076-2-101
Panel thickness min. 2.5 mm max. 4.5 mm
0353
03
21 03 841 2525
M12 Panel feed-through Crimp
Female 5 poles, B-coding
Further information and data sheets see www.HARTING.com
M12 Panel feed-through Crimp B-coded
Identification Part No. Drawing Dimensions in mm
Mating face
B-coding Mating face
acc. to IEC 61 076-2-101
Panel thickness min. 2.5 mm max. 4.5 mm
0354
03
21 03 339 1301
21 03 330 1300
M12 Panel feed-through
Male B-coding, 20 cm conductors, 0.25 mm²
Further information and data sheets see www.HARTING.com
M12 Panel feed-through B-coded
Identification Part No. Drawing Dimensions in mm
Mating face
B-coding Mating face
acc. to IEC 61 076-2-101
M12-male/female panel feed-through
B-coding
Rated voltage 24 V AC/DC
Thread M16 x 1.5
Panel thickness min. 2.0 mm max. 5.0 mm
Panel thickness min. 2.0 mm max. 5.0 mm
0355
03
21 03 339 2301
M12 Panel feed-through
Female B-coding, 20 cm conductors, 0.25 mm²
Further information and data sheets see www.HARTING.com
M12 Panel feed-through B-coded
Identification Part No. Drawing Dimensions in mm
Mating face
B-coding Mating face
acc. to IEC 61 076-2-101
Panel thickness min. 2.0 mm max. 5.0 mm
0356
03
21 03 341 1505
Further information and data sheets see www.HARTING.com
M12 PCB adapter B-coded
Identification Part No. Drawing Dimensions in mm
Mating face
M12 PCB adapterMale, B-coding, straight
5 poles, IP20
B-coding Mating face
acc. to IEC 61 076-2-101
Technical characteristics: M12 PCB adapterDegree of protection IP20, IP67
(mated and locked)
Rated current max. 4 A (dependant on PCB layout)
Rated voltage 50 V
Mating cycles max. 100
Limiting temperature -40 °C … +85 °C
Temperature during connection -5 °C … +50 °C
Termination PIH
Contact material Copper alloy
Contact plating (mating side) Au over Ni
Insulator material PA
0357
03
21 03 341 2505
Further information and data sheets see www.HARTING.com
M12 PCB adapter B-coded
Identification Part No. Drawing Dimensions in mm
Mating face
M12 PCB adapterFemale, B-coding, straight
5 poles, IP20
B-coding Mating face
acc. to IEC 61 076-2-101
0358
03
21 03 341 1518*
21 03 301 1000
21 03 301 1001
M12 PCB adapter, shielded
Male 5 poles, B-coding
for rear mounting
for front mounting
Housing
M12 PCB adapter shielded B-coded
Identification Part No. Drawing Dimensions in mm
Mating face
B-coding Mating face
acc. to IEC 61 076-2-101
Further information and data sheets see www.HARTING.com* UL approval is in preparation
0359
03
21 03 341 2518*
21 03 301 2000
21 03 301 2001
M12 PCB adapter, shielded
Female 5 poles, B-coding
for rear mounting
for front mounting
Housing
M12 PCB adapter shielded B-coded
Identification Part No. Drawing Dimensions in mm
Mating face
B-coding Mating face
acc. to IEC 61 076-2-101
Further information and data sheets see www.HARTING.com* UL approval is in preparation
0360
03
09 99 000 0501
09 99 000 0531
09 67 000 3576 09 67 000 8576 09 67 000 5576
09 67 000 347609 67 000 8476 09 67 000 5476
09 99 000 0382
09 99 000 0384
21 01 000 0003
Identification PartNo. Drawing
M12 Accessories
Crimping toolfor M12 Crimp
Accessories M12 Crimp
Locator
D-Sub single contacts (500 mating cycles)
turned male contacts AWG 22-18 / 0.33-0.82 mm² AWG 24-20 / 0.25-0.52 mm² AWG 26-22 / 0.13-0.33 mm²
turned female contacts AWG 22-18 / 0.33-0.82 mm² AWG 24-20 / 0.25-0.52 mm² AWG 26-22 / 0.13-0.33 mm²
aAWG 22-18 1.34AWG 24-20 1.13AWG 26-22 0.88
M12 dynamometric screwdriver
Tightening torque 0.6 Nm
for M12-S
for M12-L
Cap M12for IP65 / IP67Seals material VitonPlastic cap for female
Further information and data sheets see www.HARTING.com
SW 13
SW 17
D-Sub contacts
Part number AWG Tool settings
09 67 000 3x76
18 6
20 6
22 5
09 67 000 8x76 20, 22, 24 6
09 67 000 5x76 22, 24, 26 6
0361
03
21 01 000 0033
21 01 000 0038
21 01 000 0030
21 01 000 0031
M12 Accessories
Identification Part No. Drawing Dimensions in mm
Cap metal M12for IP65 / IP67 M12 metal cap for male side with cord
Cap metal M12for IP65 / IP67 M12 metal cap for male side with cable clip
Cap metal M12for IP65 / IP67 M12 metal cap for female side with cord
Cap metal M12for IP65 / IP67 M12 metal cap for female side with cable clip
Further information and data sheets see www.HARTING.com
0362
03
21 01 000 0018
21 01 010 201521 01 010 2007
21 01 010 2017
21 03 030 1300
21 03 341 6401
Accessories M12
Lock nut
M12 Accessories
Identification Part No. Drawing Dimensions in mm
Seal M12-L unshieldedfor 4.7 - 6 mm cable Øfor 6 - 8 mm cable Ø
Set of seals M12-L shieldedfor 4.5 - 5.4 mm cable Øfor 5.4 - 7.2 mm cable Øfor 7.2 - 8.8 mm cable Ø
M12-male moving load
B-coding
Further information and data sheets see www.HARTING.com
HARTING M12 T-Coupler
0363
03
M12 Circular connectors
Directory Page
3.3 D-coded – Solutions for Ethernet applications
o Technical characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 03.64
Cableconnectors • HARAX ® M12 L shielded . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 03.66 • M12Crimp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 03.68 • M12preLink® . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 03.71 • System cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 03.73
Deviceconnectors • Panelfeed-through . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 03.78 • PCBadapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 03.86
o Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 03.91
0364
03Type M12 D-coded HARAX ® M12 L
shielded M12 Crimp M12 preLink®
General data
Conductor cross section
0.14 - 0.34 mm²AWG 26-220.34 - 0.5 mm²AWG 22-20
0.13 - 0.75 mm²AWG 26-18
0.10 - 0.34 mm²AWG 27-22
Diameter of individual strands ≥0.1mm X ≥0.1mm
Conductor insulation material PVC/PE X PVC/PE
Conductor diameter 1.2 - 2.0 mm 2.0 - 2.3 mm 0.8 - 1.6 mm
Cable diameter 4.5 - 8.8 mm 4 poles: 4.5 - 8.8 mm5 poles: 4.5 - 8.8 mm 6.3 - 6.7 mm
Temperature range -40 °C … +85 °C -40 °C … +85 °C -40 °C … +85 °C
Temperature during connection -5 °C … +50 °C -5 °C … +50 °C –
Degree of protection IP65 / IP67 IP67 IP65
Mating cycles 100 500 250
Tightening torque connector / Hexagonal wrench 0.6 Nm / SW 17 0.6 Nm / SW 17 0.6 Nm / SW 17
Electrical characteristics
Rated current 4 A 4 A 1 A
Rated voltage 50 V 250 V 48 V
Rated impulse voltage 1.5 kV 1.5 kV 1.5 kV
Contact resistance 10mΩ 10mΩ 10mΩ
Insulation resistance 108Ω 108Ω 108Ω
Pollution degree 3 3 3
Overvoltage category 3 3 3
Isolation group 1 1 –
Transmission performance (Category) Cat. 5 Cat. 5 Cat. 5
Materials
Contact material Brass Brass Brass
Contact plating Gold Gold Gold
Contact carrier material PA unreinforced PA –
Housing material PA unreinforced PA Zinc die-cast
Technical characteristics M12 – D-coding
M12 D-codingMating face
D-coding Mating face
acc. to IEC 61 076-2-101
Further information and data sheets see www.HARTING.com
Specifications IEC 60 352-4
Approval
0365
03
Current carrying capacity The current carrying capacity is limited by maximum temperature of materials for inserts and contacts including terminals. The current capacity-curve is valid for continuous, not interruptet current-loaded contacts of connectors when simultaneous power on all contacts is given, without exceeding the maximum temperature.
Control and test procedures according to DIN IEC 60 512-5.
Rat
ed c
urre
nt [A
]
Ambient temperature [oC]
M12-L 1 = Wire gauge 0.34 mm² 3 poles, 4 poles 2 = Wire gauge 0.75 mm²
Rat
ed c
urre
nt [A
]
Ambient temperature [oC]
M12, Crimp 1 = Wire gauge 0.34 mm² / 0.5 mm²
Further information and data sheets see www.HARTING.com
M12 D-coding
Technical characteristics M12 – D-coding
Technical characteristics M12 – D-coding, PCB adapter
Rat
ed c
urre
nt [A
]
Rat
ed c
urre
nt [A
]
Ambient temperature [oC] Ambient temperature [oC]
M12, D-coding, straight, female, 4 poles Wire gauge 0.5 mm²
M12, D-coding, angled, female, 4 poles Wire gauge AWG 22
0366
03
21 03 281 1405
21 03 282 1405
Further information and data sheets see www.HARTING.com
M12 HARAX ® D-coded
Identification Part No. Drawing Dimensions in mm
HARAX ® M12-L, shielded
Male 4 poles, D-coding 0.14 - 0.34 mm², AWG 26 - 22
Male 4 poles, D-coding 0.34 - 0.5 mm², AWG 22 - 20
•D-codingforEthernet/Profinetapplications
•Robustdesign
•360°shieldingtermination
•TransmissionperformanceCat.5
Applications / Advantages
Mating face
D-coding Mating face
acc. to IEC 61 076-2-101
0367
03
21 03 281 2405
21 03 282 2405
Further information and data sheets see www.HARTING.com
M12 HARAX ® D-coded
Identification Part No. Drawing Dimensions in mm
HARAX ® M12-L, shielded
Female 4 poles, D-coding 0.14 - 0.34 mm², AWG 26 - 22
Female 4 poles, D-coding 0.34 - 0.5 mm², AWG 22 - 20
Mating face
D-coding Mating face
acc. to IEC 61 076-2-101
0368
03
21 03 882 1405
21 03 882 1415
Further information and data sheets see www.HARTING.com
M12 Crimp D-coded
Identification Part No. Drawing Dimensions in mm
M12 Crimp, shielded
Male 4 poles, D-coding
Male 4 poles, D-coding
Mating face
D-coding Mating face
acc. to IEC 61 076-2-101
0369
03
21 03 881 1405*
21 03 882 3405*
M12 Crimp D-coded
Identification Part No. Drawing Dimensions in mm
M12 Crimp Slim design, shielded
M12 Crimp, shielded
Male 4 poles, D-coding Cable: 4.4 - 8.8 mm
outer diameter
Male 4 poles, D-coding angled
Mating face
D-coding Mating face
acc. to IEC 61 076-2-101
Further information and data sheets see www.HARTING.com* UL approval is in preparation
0370
03
21 03 882 2405
Further information and data sheets see www.HARTING.com
M12 Crimp D-coded
Identification Part No. Drawing Dimensions in mm
M12 Crimp, shielded
Female 4 poles, D-coding
Mating face
D-coding Mating face
acc. to IEC 61 076-2-101
0371
03
20 82 005 1214
20 82 000 1210
20 82 000 0001
20 82 000 0003
20 82 000 9901
Further information and data sheets see www.HARTING.com
M12 preLink ® D-coded
Identification Part No. Drawing Dimensions in mm
Mating face
D-coding Mating face
acc. to IEC 61 076-2-101
preLink ® terminal module(Pack with 10 pieces) terminal block with IDC termination
Number of contacts: 8
Conductor cross section: AWG 22/23 (24) solid and stranded
Conductor diameter: Ø 1.3 - 1.6 mmColour: yellow
Conductor cross section: AWG 26/27 solid and stranded
Conductor diameter: Ø 0.8 - 1.1 mmColour: white
preLink ® M12 housing
preLink ® M12 male moduleMale 4 poles, D-coding
Assembly tool
0372
03
Notes
0373
03Technical characteristics
Pre-assembled and tested system cables for structured cabling of industrial
Ethernet networks, based on M12 Circular connectors, D-coded
Cable type: Shielded Twisted Pair Standard Cable
Mating interface: M12 D-coded acc. to IEC 61 076-2-101
Transmission performance acc. to ISO/IEC 11801:2002: Class D, 100% tested
Degree of protection IP65 / IP67 (when mated)
Pin assignment
Signal Function Conductor colourPROFInet®
Contact assignment
TD+ Transmission Data+ Yellow 1
TD- Transmission Data- Orange 3
RD+ Receiver Data+ White 2
RD- Receiver Data- Blue 4
Further information and data sheets see www.HARTING.com
M12 System cables, D-codingMating face
D-coding Mating face
acc. to IEC 61 076-2-101
0374
03Overview system cables M12
M12 System cables, D-codingMating face
D-coding Mating face
acc. to IEC 61 076-2-101
Male M12 D-codingstraight
Number of contacts
Cable material: PUR Cable material: PVC
Mal
e M
12
stra
ight
1.0 m 21 03 485 1401 09 48 222 2004 010* 1.0 m 09 47 222 2002
09 48 222 2003 010*
1.5 m 21 03 485 1451 09 48 222 2004 015* 1.5 m 09 47 222 2003
09 48 222 2003 015*
3.0 m 21 03 485 1403 09 48 222 2004 030* 3.0 m 09 47 222 2005
09 48 222 2003 030*
5.0 m 21 03 485 1405 09 48 222 2004 050* 5.0 m 09 47 222 2006
09 48 222 2003 050*
7.5 m 21 03 485 1457 09 48 222 2004 075* 7.5 m 09 47 222 2022
09 48 222 2003 075*
10.0 m 21 03 485 1410 09 48 222 2004 100* 10.0 m 09 47 222 2011
09 48 222 2003 100*
20.0 m 21 03 485 1420 09 48 222 2004 200* 20.0 m 09 47 222 2013
09 48 222 2003 200*
Ope
n en
d
1.0 m 21 03 585 1401 09 48 220 0004 010* 1.0 m 09 47 220 0002
09 48 220 0003 010*
1.5 m 21 03 585 1451 09 48 220 0004 015* 1.5 m 09 47 220 0003
09 48 220 0003 015*
3.0 m 21 03 585 1403 09 48 220 0004 030* 3.0 m 09 47 220 0005
09 48 220 0003 030*
5.0 m 21 03 585 1405 09 48 220 0004 050* 5.0 m 09 47 220 0006
09 48 220 0003 050*
7.5 m 21 03 585 1457 09 48 220 0004 075* 7.5 m 09 47 220 0022
09 48 220 0003 075*
10.0 m 21 03 585 1410 09 48 220 0004 100* 10.0 m 09 47 220 0011
09 48 220 0003 100*
20.0 m 21 03 585 1420 09 48 220 0004 200* 20.0 m 09 47 220 0013
09 48 220 0003 200*
* Mid 2014 the part numbers beginning with 21 03 … or 09 47 … will be replaced by the part numbers beginning with 09 48 ... The former part numbers will be set to status inactive. Please use only the part numbers beginning with 09 48 … for your order.
0375
03Overview system cables M12
M12 System cables, D-codingMating face
D-coding Mating face
acc. to IEC 61 076-2-101
Male M12 D-codingangled
Number of contacts
Cable material: PUR Cable material: PVC
Mal
e M
12
angl
ed
1.0 m 21 03 485 3401 09 48 808 0004 010* 1.0 m 09 47 808 0002
09 48 808 0003 010*
1.5 m 21 03 485 3451 09 48 808 0004 015* 1.5 m 09 47 808 0003
09 48 808 0003 015*
3.0 m 21 03 485 3403 09 48 808 0004 030* 3.0 m 09 47 808 0005
09 48 808 0003 030*
5.0 m 21 03 485 3405 09 48 808 0004 050* 5.0 m 09 47 808 0006
09 48 808 0003 050*
7.5 m 21 03 485 3457 09 48 808 0004 075* 7.5 m 09 47 808 0022
09 48 808 0003 075*
10.0 m 21 03 485 3410 09 48 808 0004 100* 10.0 m 09 47 808 0011
09 48 808 0003 100*
20.0 m 21 03 485 3420 09 48 808 0004 200* 20.0 m 09 47 808 0013
09 48 808 0003 200*
Ope
n en
d
1.0 m 21 03 585 3401 09 48 800 0004 010* 1.0 m 09 47 800 0002
09 48 800 0003 010*
1.5 m 21 03 585 3451 09 48 800 0004 015* 1.5 m 09 47 800 0003
09 48 800 0003 015*
3.0 m 21 03 585 3403 09 48 800 0004 030* 3.0 m 09 47 800 0005
09 48 800 0003 030*
5.0 m 21 03 585 3405 09 48 800 0004 050* 5.0 m 09 47 800 0006
09 48 800 0003 050*
7.5 m 21 03 585 3457 09 48 800 0004 075* 7.5 m 09 47 800 0022
09 48 800 0003 075*
10.0 m 21 03 585 3410 09 48 800 0004 100* 10.0 m 09 47 800 0011
09 48 800 0003 100*
20.0 m 21 03 585 3420 09 48 800 0004 200* 20.0 m 09 47 800 0013
09 48 800 0003 200*
* Mid 2014 the part numbers beginning with 21 03 … or 09 47 … will be replaced by the part numbers beginning with 09 48 ... The former part numbers will be set to status inactive. Please use only the part numbers beginning with 09 48 … for your order.
0376
03
21 03 485 140121 03 485 145121 03 485 140321 03 485 140521 03 485 145721 03 485 141021 03 485 1420
21 03 585 140121 03 585 145121 03 585 140321 03 585 140521 03 585 145721 03 585 141021 03 585 1420
21 03 485 340121 03 485 345121 03 485 340321 03 485 340521 03 485 345721 03 485 341021 03 485 3420
21 03 585 340121 03 585 345121 03 585 340321 03 585 340521 03 585 345721 03 585 341021 03 585 3420
* other lengths on request
1 x M12 Circular connectors, D-coding, PUR, straight
2 x M12 Circular connectors, D-coding, PUR, straight
Length*: 1.0 m1.5 m
3.0 m 5.0 m
7.5 m10.0 m20.0 m
Length*: 1.0 m1.5 m
3.0 m 5.0 m
7.5 m10.0 m20.0 m
Length*: 1.0 m1.5 m
3.0 m 5.0 m
7.5 m10.0 m20.0 m
Length*: 1.0 m1.5 m
3.0 m 5.0 m
7.5 m10.0 m20.0 m
Cable: AWG 22 / 0.34 mm²
Cable: AWG 22 / 0.34 mm²
Identification PartNo. Drawing Dimensionsinmm
1 x M12 Circular connectors, D-coding, PUR, angled
2 x M12 Circular connectors, D-coding, PUR, angled
Cable: AWG 22 / 0.34 mm²
Cable: AWG 22 / 0.34 mm²
M12 System cables, D-coding
Further information and data sheets see www.HARTING.com
0377
03
09 47 222 200209 47 222 200309 47 222 200509 47 222 200609 47 222 202209 47 222 201109 47 222 2013
09 47 220 000209 47 220 000309 47 220 000509 47 220 000609 47 220 002209 47 220 001109 47 220 0013
09 47 808 000209 47 808 000309 47 808 000509 47 808 000609 47 808 002209 47 808 001109 47 808 0013
09 47 800 000209 47 800 000309 47 800 000509 47 800 000609 47 800 002209 47 800 001109 47 800 0013
* other lengths on request
1 x M12 Circular connectors, D-coding, PVC, straight
2 x M12 Circular connectors, D-coding, PVC, straight
Length*: 1.0 m1.5 m
3.0 m 5.0 m
7.5 m10.0 m20.0 m
Length*: 1.0 m1.5 m
3.0 m 5.0 m
7.5 m10.0 m20.0 m
Length*: 1.0 m1.5 m
3.0 m 5.0 m
7.5 m10.0 m20.0 m
Length*: 1.0 m1.5 m
3.0 m 5.0 m
7.5 m10.0 m20.0 m
Cable: AWG 22 / 0.34 mm²
Cable: AWG 22 / 0.34 mm²
Identification PartNo. Drawing Dimensionsinmm
1 x M12 Circular connectors, D-coding, PVC, angled
2 x M12 Circular connectors, D-coding, PVC, angled
Cable: AWG 22 / 0.34 mm²
Cable: AWG 22 / 0.34 mm²
M12 System cables, D-coding
Further information and data sheets see www.HARTING.com
0378
03
21 03 381 1425
Further information and data sheets see www.HARTING.com
M12 Panel feed-through HARAX ® D-coded
Identification Part No. Drawing Dimensions in mm
HARAX ® Panel feed-through
Male 4 poles, D-coding 0.14 - 0.34 mm² / AWG 26 - 22
•D-codingforEthernet/Profinetapllications
•PatentHARAX® fast termination
•Robustdesign
•360°shieldingtermination
•TransmissionperformanceCat.5
Applications / Advantages
Mating face
D-coding Mating face
acc. to IEC 61 076-2-101
Panel thickness min. 2.5 mm max. 4.5 mm
0379
03
21 03 381 2425
Further information and data sheets see www.HARTING.com
M12 Panel feed-through HARAX ® D-coded
Identification Part No. Drawing Dimensions in mm
HARAX ® Panel feed-through
Female 4 poles, D-coding 0.14 - 0.34 mm² / AWG 26 - 22
Mating face
D-coding Mating face
acc. to IEC 61 076-2-101
Panel thickness min. 2.5 mm max. 4.5 mm
0380
03
21 03 882 1425
Further information and data sheets see www.HARTING.com
M12 Panel feed-through Crimp D-coded
Identification Part No. Drawing Dimensions in mm
M12 Panel feed-through Crimp
Male 4 poles, D-coding
Mating face
D-coding Mating face
acc. to IEC 61 076-2-101
Panel thickness min. 2.5 mm max. 4.5 mm
0381
03
21 03 882 2425
Further information and data sheets see www.HARTING.com
M12 Panel feed-through Crimp D-coded
Identification Part No. Drawing Dimensions in mm
M12 Panel feed-through Crimp
Female 4 poles, D-coding
Mating face
D-coding Mating face
acc. to IEC 61 076-2-101
Panel thickness min. 2.5 mm max. 4.5 mm
0382
03
21 03 371 1403
Further information and data sheets see www.HARTING.com
M12 Panel feed-through D-coded
Identification Part No. Drawing Dimensions in mm
M12 Panel feed-through
Male D-coding 50 cm conductors, AWG 22, 4 poles
Mating face
D-coding Mating face
acc. to IEC 61 076-2-101
Panel thickness min. 2.0 mm max. 5.0 mm
0383
03
21 03 371 2403
Further information and data sheets see www.HARTING.com
M12 Panel feed-through D-coded
Identification Part No. Drawing Dimensions in mm
M12 Panel feed-through
Female D-coding 50 cm conductors, AWG 22, 4 poles
Mating face
D-coding Mating face
acc. to IEC 61 076-2-101
Panel thickness min. 2.0 mm max. 5.0 mm
0384
03
21 03 381 4400
21 03 381 4401*
21 03 381 2400
21 03 381 2401*
21 03 371 1420
M12 Panel feed-through D-coded
Identification Part No. Drawing Dimensions in mm
M12 Female-RJ45 Panel feed-through
M12 Female-RJ45 Panel feed-through
M12 Male-RJ45 Adapter
4 poles, D-coding angled
4 poles, D-coding straight
4 poles, D-coding straight (coupler, without thread in the termination area)
Mating face
D-coding Mating face
acc. to IEC 61 076-2-101
Further information and data sheets see www.HARTING.com* UL approval is in preparation
Panel thickness min. 2.1 mm max. 4.5 mm
Panel thickness min. 2.1 mm max. 4.5 mm
0385
03
21 03 381 6405
21 03 381 6401*
21 01 000 0036
Further information and data sheets see www.HARTING.com
M12 Panel feed-through D-coded
Identification Part No. Drawing Dimensions in mm
M12 Gender Changer Female-Female
M12 Gender Changer Female-Female
4 poles, D-coding Cat. 5
4 poles, D-coding Cat. 5
Mating face
D-coding Mating face
acc. to IEC 61 076-2-101
Further information and data sheets see www.HARTING.com* UL approval is in preparation
Wall bracket
0386
03
21 03 371 1400
Further information and data sheets see www.HARTING.com
M12 PCB adapter D-coded
Identification Part No. Drawing Dimensions in mm
Mating face
D-coding Mating face
acc. to IEC 61 076-2-101
M12 PCB adapterMale, D-coding, straight
4 poles, IP67
Technical characteristics: M12 PCB adapter D-coded angledDegree of protection IP20, IP67
(mated and locked)
Rated current max. 4 A (dependant on PCB layout)
Rated voltage 50 V
Mating cycles max. 100
Limiting temperature -40 °C … +85 °C
Temperature during connection -5 °C … +50 °C
Termination Reflow
Contact material Copper alloy
Contact plating (mating side) Au over Ni
Insulator material LCP
0387
03
21 03 371 2415
21 03 381 6410
21 03 381 6420
Further information and data sheets see www.HARTING.com
M12 PCB adapter D-coded
Identification Part No. Drawing Dimensions in mm
Mating face
D-coding Mating face
acc. to IEC 61 076-2-101
M12 PCB adapterFemale, D-coding, straight
4 poles, IP67
4 poles, IP20
4 poles, IP67
0388
03
21 03 381 44101)
21 03 381 44112)
21 03 381 44301)
21 03 381 44121)
21 03 381 44132)
21 03 381 44321)
Identification Part No. Drawing Dimensions in mm
M12 PCB adapterFemale, D-coding, angled, 4 poles
without fixing hole
with fixing hole
1) Cable direction to the right
2) Cable direction to the bottom
Further information and data sheets see www.HARTING.com
M12 PCB adapter D-codedMating face
D-coding Mating face
acc. to IEC 61 076-2-101
IP20
IP20
IP67
IP20
IP20
IP67
0389
03
21 03 381 1418*
21 03 301 1000
21 03 301 1001
M12 PCB adapter, shielded
Male 4 poles, D-coding
for rear mounting
for front mounting
Housing
M12 PCB adapter shielded D-coded
Identification Part No. Drawing Dimensions in mm
Mating face
D-coding Mating face
acc. to IEC 61 076-2-101
Further information and data sheets see www.HARTING.com* UL approval is in preparation
0390
03
21 03 381 2418*
21 03 301 2000
21 03 301 2001
M12 PCB adapter, shielded
Female 4 poles, D-coding
for rear mounting
for front mounting
Housing
M12 PCB adapter shielded D-coded
Identification Part No. Drawing Dimensions in mm
Mating face
D-coding Mating face
acc. to IEC 61 076-2-101
Further information and data sheets see www.HARTING.com* UL approval is in preparation
0391
03
09 99 000 0501
09 99 000 0531
21 01 000 0018
09 67 000 3576 09 67 000 8576 09 67 000 5576
09 67 000 347609 67 000 8476 09 67 000 5476
21 01 010 2017
09 99 000 0646
09 99 000 0384
Identification PartNo. Drawing
M12 Accessories
Crimping toolfor M12 Crimp
Accessories M12 Crimp
Accessories M12
Locator
Lock nut
D-Sub single contacts (500 mating cycles)
turned male contacts AWG 22-18 / 0.33-0.82 mm² AWG 24-20 / 0.25-0.52 mm² AWG 26-22 / 0.13-0.33 mm²
turned female contacts AWG 22-18 / 0.33-0.82 mm² AWG 24-20 / 0.25-0.52 mm² AWG 26-22 / 0.13-0.33 mm²
aAWG 22-18 1.34AWG 24-20 1.13AWG 26-22 0.88
Set of seals M12-L shieldedfor 4.5 - 5.4 mm cable Øfor 5.4 - 7.2 mm cable Øfor 7.2 - 8.8 mm cable Ø
M12 dynamometric screwdriver
Tightening torque 0.6 Nm
for M12 Slim design
for M12-L
Further information and data sheets see www.HARTING.com
SW 15
SW 17
D-Sub contacts
Part number AWG Tool settings
09 67 000 3x76
18 6
20 6
22 5
09 67 000 8x76 20, 22, 24 6
09 67 000 5x76 22, 24, 26 6
0392
03
21 01 000 0033
21 01 000 0038
21 01 000 0030
21 01 000 0031
21 01 000 0003
M12 Accessories
Cap M12for IP65 / IP67Seals material VitonPlastic cap for female
Further information and data sheets see www.HARTING.com
Identification Part No. Drawing Dimensions in mm
Cap metal M12for IP65 / IP67 M12 metal cap for male side with cord
Cap metal M12for IP65 / IP67 M12 metal cap for male side with cable clip
Cap metal M12for IP65 / IP67 M12 metal cap for female side with cord
Cap metal M12for IP65 / IP67 M12 metal cap for female side with cable clip
0401
04
M12 Circular connectors
Directory Page
4. har-speed M12 data connectors
4.1 X-coded – Solutions for high-speed applications
o Technical characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 04.02
Cableconnectors • har-speed M12 connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 04.05 • System cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 04.06
Deviceconnectors • har-speed M12 Panel feed-through . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 04.07 • har-speed PCB connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 04.09
o Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 04.13
0402
04
Type M12 X-coded har-speed M12 har-speed M12 Slim design
General data
Conductor cross section 0.08 - 0.25 mm²AWG 28-23
Diameter of individual strands –
Conductor insulation material –
Conductor diameter 0.33 - 0.61 mm
Cable diameter 4.5 - 8.8 mm
Temperature range -40 °C … +85 °C
Temperature during connection -5 °C … +50 °C
Degree of protection IP65 / IP67
Mating cycles 500
Tightening torque connector / hexagonal wrench 0.6 Nm / SW 15
Electrical characteristics
Rated current 0.5 A
Rated voltage 48 V
Rated impulse voltage 1.5 kV
Contact resistance 15mΩ
Insulation resistance 108Ω
Pollution degree 3
Overvoltage category 3
Isolation group 1
Transmission performance (Category) Cat. 6A
Materials
Contact material Brass
Contact plating Gold
Contact carrier material LCP
Housing material ZP410
Technical characteristics M12 – X-coding
M12 X-codingMating face
X-coding Mating face
acc. to IEC 61 076-2-101
Specifications IEC 60 352-4
Approval
Further information and data sheets see www.HARTING.com* UL approval is in preparation
0403
04
Technical characteristics M12 – X-codingCurrent carrying capacity The current carrying capacity is limited by maximum temperature of materials for inserts and contacts
including terminals. The current capacity-curve is valid for continuous, not interruptet current-loaded contacts of connectors when simultaneous power on all contacts is given, without exceeding the maximum temperature.
Control and test procedures according to DIN IEC 60 512-5.
har-speed M12 8 poles
har-speed M12 PCB adapter
Further information and data sheets see www.HARTING.com
M12 X-coding
0404
04
Notes
0405
04
21 03 881 5805
21 03 881 1805
Further information and data sheets see www.HARTING.com
har-speed M12 X-coded
Identification Part No. Drawing Dimensions in mm
har-speed M12
har-speed M12 Slim design
Male straight version 8 poles, Cat. 6A Cable diameter: 4.5 - 8.8 mm
Male straight version 8 poles, Cat. 6A Cable diameter: 4.5 - 8.8 mm
•High-SpeedEthernetapplicationsforprocessautomatization,e.g.camerasystemforprocess control in the production
•MaxiumumdataratesthroughtheconfigurationofthecontactsinconformancewithEthernet technology. Transfer class EA for 1 and 10 Gigabit
•Perfectshieldingthroughpairedshieldingofthecontacts
•Overmouldedsystemcablesinvariouslengths
Applications / Advantages
Mating face
X-coding Mating face
acc. to IEC 61 076-2-101
0406
04
21 03 483 180121 03 483 180321 03 483 180521 03 483 180721 03 483 1810
21 03 483 585021 03 483 580121 03 483 585121 03 483 580221 03 483 5852
har-speed M12 System cables X-coded
Identification PartNo. Drawing Dimensionsinmm
har-speed M12 System cables
single ended overmoulded system cable
double ended overmoulded system cable
Length: 1 m3 m5 m7 m
10 m
Length: 0.5 m1.0 m1.5 m2.0 m2.5 m
Further information and data sheets see www.HARTING.com
Mating face
X-coding Mating face
acc. to IEC 61 076-2-101
0407
04
21 03 381 2800
21 03 381 4800
Further information and data sheets see www.HARTING.com
har-speed M12 Panel feed-through X-coded
Identification Part No. Drawing Dimensions in mm
Mating face
har-speed M12 Adapter M12-RJ45
straight, Cat. 6A
angled, Cat. 6A
X-coding Mating face
acc. to IEC 61 076-2-101
Panel thickness min. 2.1 mm max. 4.5 mm
Panel thickness min. 2.1 mm max. 4.5 mm
0408
04
21 03 381 6815
21 01 000 0036
Further information and data sheets see www.HARTING.com
har-speed M12 Panel feed-through X-coded
Identification Part No. Drawing Dimensions in mm
Mating face
X-coding Mating face
acc. to IEC 61 076-2-101
Gender changer, Cat. 6A
Wall bracket
0409
04
21 03 381 2802
21 03 381 2803
21 03 381 4802
Further information and data sheets see www.HARTING.com
har-speed M12 PCB adapter X-coded
Identification Part No. Drawing Dimensions in mm
Mating face
X-coding Mating face
acc. to IEC 61 076-2-101
har-speed M12 PCB adapter
Female, X-coding, straight, Cat. 6A for front mounting
har-speed M12 PCB adapter
Female, X-coding, straight, Cat. 5 for front mounting
har-speed M12 PCB adapter
Female, X-coding, angled, Cat. 6A for front mounting
0410
04
21 03 381 2804
21 03 381 2805
21 03 381 2809
21 03 381 4804
Further information and data sheets see www.HARTING.com
har-speed M12 PCB adapter X-coded
Identification Part No. Drawing Dimensions in mm
X-coding Mating face
acc. to IEC 61 076-2-101
har-speed M12 PCB adapter
Female, X-coding, straight, Cat. 6A for rear mounting
har-speed M12 PCB adapter
Female, X-coding, straight, Cat. 5 for rear mounting
har-speed M12 PCB adapter
Female, X-coding, angled, Cat. 6A for rear mounting
Mating face
0411
04
21 03 381 2806
21 03 381 2807
21 03 301 2000
21 03 301 2001
har-speed M12 PCB adapter
Female 8 poles, X-codingCat. 6A
Female 8 poles, X-codingCat. 5
for rear mounting
for front mounting
Housing
Further information and data sheets see www.HARTING.com
har-speed M12 PCB adapter X-coded
Identification Part No. Drawing Dimensions in mm
X-coding Mating face
acc. to IEC 61 076-2-101
Mating face
0412
04
21 03 381 2801
har-speed M12 PCB adapter X-coded
Identification Part No. Drawing Dimensions in mm
Mating face
X-coding Mating face
acc. to IEC 61 076-2-101
har-speed M12 PCB adapter
Female, X-coding, straight, Cat. 6A for front mounting
Further information and data sheets see www.HARTING.com
0413
04
09 99 000 0501
09 99 000 0525
21 01 000 0018
21 01 100 9014
21 01 100 9019
09 99 000 0646
Identification PartNo. Drawing
har-speed M12 Accessories
Crimping toolfor har-speed M12
Accessories har-speed M12
Accessories M12
Locator
Lock nut
Single contacts (500 mating cycles)
har-speed M12 contacts AWG 28-24 / 0.08-0.22 mm²
har-speed M12 contacts AWG 26-23 / 0.13-0.25 mm²
Further information and data sheets see www.HARTING.com
M12 dynamometric screwdriver
Tightening torque 0.6 Nm
for M12 Slim design SW 15
har-speed contacts
Part number AWG Tool settings
21 01 100 9014
28 3
26 4
24 5
21 01 100 9019
26 4
24 5
23 5
0414
04
21 01 000 0033
21 01 000 0038
21 01 000 0030
21 01 000 0031
21 01 000 0003
har-speed M12 Accessories
Identification Part No. Drawing Dimensions in mm
Cap metal M12for IP65 / IP67 M12 metal cap for male side with cord
Cap metal M12for IP65 / IP67 M12 metal cap for male side with cable clip
Cap metal M12for IP65 / IP67 M12 metal cap for female side with cord
Cap metal M12for IP65 / IP67 M12 metal cap for female side with cable clip
Cap M12for IP65 / IP67Seals material VitonPlastic cap for female
Further information and data sheets see www.HARTING.com
0501
05
M8 / M12 Circular connectors
Directory Page
5. 7/8” HARAX ®
5.1 7/8” HARAX ®-Power-Circular connectors
o Technical characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 05.02
Cableconnectors • 7/8” HARAX ® Male . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 05.04 • 7/8”HARAX ® Female . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 05.05 • Systemcables. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 05.06
Deviceconnectors • Panel feed-through . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 05.10
o Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 05.12
0502
05
Technical characteristics 7/8“ HARAX ®
Specifications IEC 60 352-4 DIN 61 984
Approval , VDE
Type 7/8“ HARAX ®
General data
Conductor cross section 0.75 - 1.5 mm² AWG 18-16
Diameter of individual strands ≥0.15mm
Conductor insulation material PVC, PP, TPE
Conductor diameter ≤2.8mm
Cable diameter 6.8 - 9.5 mm (black) 9 - 12.5 mm (grey)
Temperature range -40 °C … +85 °C
Temperature during connection -5 °C … +50 °C
Degree of protection IP65 / IP67
Mating cycles 100
Recommended tightening torque / Hexagonal wrench 1.5 Nm / SW 22
Electrical characteristics
Rated current 10 A
Rated voltage 230 V / 400 V
Rated impulse voltage 4.8 kV
Contact resistance 10mΩ
Insulation resistance 108Ω
Pollution degree 3
Overvoltage category 3
Isolation group 1
Materials
Contact material Copper alloy
Contact plating Gold
Contact carrier material TPU, PA
Housing material TPU, zinc die-cast, PA
Mating face
Further information and data sheets see www.HARTING.com
Mating face acc. to IEC 61 076-2-101
7/8“ HARAX ®
0503
05
Further information and data sheets see www.HARTING.com
Technical characteristics – System cables, 7/8“ HARAX ®Degree of protection IP67
Temperature range apllies to moved cable -20 °C … +80 °C cables permanently installed -50 °C … +80 °C
Rated current max. 8 A every contact (+40 °C)
Rated voltage 230 / 400 V
Rated impulse voltage 3 kV
Pollution degree 3
Material group Category I acc. to IEC 60 664-1
Cable data
Jacket material PUR
Jacket colour grey
Wire isolation TPM
Wire colours brown, white, blue, black, green/yellow
Wire gauge 5 x 1.5 mm²
Standards UL / CSA
Technical characteristics 7/8“ HARAX ®Current carrying capacity The current carrying capacity is limited by maximum temperature of materials for inserts and contacts
including terminals. The current capacity-curve is valid for continuous, not interruptet current-loaded contacts of connectors when simultaneous power on all contacts is given, without exceeding the maximum temperature.
Control and test procedures according to DIN IEC 60 512-5.
Rat
ed c
urre
nt [A
]
Ambient temperature [oC]
7/8“ 1 = Wire gauge 0.75 mm² / 1.5 mm²
7/8“ HARAX ®
0504
05
21 04 116 1505
Further information and data sheets see www.HARTING.com
Identification Part No. Drawing Dimensions in mm
7/8“ HARAX ® Male
•The reliable connector for power applications
•PatentHARAX® fast termination
•Overmouldedsystemcablesinvariouslengths
•Robustdesign,quickassembly
Applications / Advantages
Mating face
Mating face acc. to IEC 61 076-2-101
7/8“ HARAX ®
0505
05
21 04 116 2505
Further information and data sheets see www.HARTING.com
Identification Part No. Drawing Dimensions in mm
Mating face
Mating face acc. to IEC 61 076-2-101
7/8“ HARAX ® Female
7/8“ HARAX ®
0506
05
7/8’’ System cablesMating face
Mating face acc. to IEC 61 076-2-101
Degree of protection IP67
Temperature range applies to moved cable -20 °C … +80 °C cables permanently installed -50 °C … +80 °C
Rated current max. 8 A every contact (+40 °C)
Rated voltage 230 / 400 V
Rated impulse voltage 3 kV
Pollution degree 3
Material group Category I acc. to IEC 60 664-1
Cable data
Jacket material PUR
Jacket colour grey
Wire isolation TPM
Wire colours brown, white, blue, black, green/yellow
Wire gauge 5 x 1.5 mm²
Standards UL / CSA
Technical characteristics
0507
05
7/8’’ System cablesMating face
Mating face acc. to IEC 61 076-2-101
Overview system cables 7/8“Male 7/8“
straight angled
Number of contacts
Cable material: PUR Cable material: PUR
Fem
ale
7/8“
stra
ight
0.3 m 21 04 416 1501 xxx
0.6 m 21 04 416 1502 xxx
1.0 m 21 04 416 1503 xxx
1.5 m 21 04 416 1504 xxx
2.0 m 21 04 416 1505 xxx
angl
ed
xxx 0.3 m 21 04 416 3501
xxx 0.6 m 21 04 416 3502
xxx 1.0 m 21 04 416 3503
xxx 1.5 m 21 04 416 3504
xxx 2.0 m 21 04 416 3505
Female 7/8“
straight angled
Number of contacts
Cable material: PUR Cable material: PUR
Ope
n en
d
1.5 m 21 04 516 2501 1.5 m 21 04 516 4501
3.0 m 21 04 516 2502 3.0 m 21 04 516 4502
5.0 m 21 04 516 2503 5.0 m 21 04 516 4503
7.5 m 21 04 516 2504 7.5 m 21 04 516 4504
10.0 m 21 04 516 2505 10.0 m 21 04 516 4505
0508
05
21 04 516 2302
21 04 516 1402
7/8’’ System cables
Identification PartNo. Drawing Dimensionsinmm
Overmoulded cordsets 7/8’’ Female straight 3 poles
Length: 2.0 m
Length: 2.0 m
Overmoulded cordsets 7/8’’ Male straight 4 poles
Schematic diagram
Schematic diagram
View mating side
View mating side
Further information and data sheets see www.HARTING.com
0509
05
21 04 516 250121 04 516 250221 04 516 250321 04 516 250421 04 516 2505
21 04 416 150121 04 416 150221 04 416 150321 04 416 150421 04 416 1505
21 04 516 450121 04 516 450221 04 516 450321 04 516 450421 04 516 4505
21 04 416 350121 04 416 350221 04 416 350321 04 416 350421 04 416 3505
7/8’’ System cables
Identification PartNo. Drawing Dimensionsinmm
Overmoulded cordsets 7/8’’ Female straight 5 poles Length: 1.5 m
3.0 m5.0 m7.5 m
10.0 m
Length: 0.3 m0.6 m1.0 m1.5 m2.0 m
Length: 1.5 m3.0 m5.0 m7.5 m
10.0 m
Length: 0.3 m0.6 m1.0 m1.5 m2.0 m
Overmoulded cordsets 7/8’’ Male-Female straight 5 poles
Overmoulded cordsets 7/8’’ Female angled 5 poles
Overmoulded cordsets 7/8’’ Male-Female angled 5 poles
Schematic diagram
Schematic diagram
Schematic diagram
Schematic diagram
View mating side
View mating side
View mating side
View mating side
Further information and data sheets see www.HARTING.com
0510
05
21 04 316 1305
21 04 316 1505
500
Mating face
Mating face acc. to IEC 61 076-2-101
7/8“ Panel feed-through 20 cm conductors, AWG 18, 1 mm², 3 poles
7/8“ Panel feed-through 50 cm conductors, AWG 18, 1 mm², 5 poles
7/8“ Panel feed-through
Identification Part No. Drawing Dimensions in mm
Further information and data sheets see www.HARTING.com
Male
Male
0511
05
21 04 316 2505
21 04 316 2400
500
Mating face
Mating face acc. to IEC 61 076-2-101
7/8“ Panel feed-through
Identification Part No. Drawing Dimensions in mm
7/8“ Panel feed-through 50 cm conductors, AWG 18, 1 mm², 5 poles
7/8“ Panel feed-through 20 cm conductors, AWG 18, 1 mm², 4 poles
Further information and data sheets see www.HARTING.com
Female
Female
0512
05
21 01 000 0020
09 99 000 0395
7/8“ Accessories
Identification Part No. Drawing Dimensions in mm
Lock nut Pg 13.5nickel plated
7/8“ dynamometric screwdriver
Tightening torque 1.5 Nm
for 7/8“
Further information and data sheets see www.HARTING.com
SW 23
0601
06
M8 / M12 Circular connectors
Directory Page
6. HARAX ® Panel feed-through
6.1 HARAX ® Panel feed-through
o Technical characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 06.02
Cableconnectors • HARAX ® Pg 13.5 / M20 Panel feed-through . . . . . . . . . . . . . . . . . . . . . . . . 06.04
o Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 06.05
0602
06
Technical characteristics Panel feed-through
Specifications IEC 60 352-4 DIN 61 984
Approval , VDE
HARAX ® Panel feed-through
Type HARAX ® Pg 13.5/M20 Panel feed-through
General data
Conductor cross section 0.75 - 1.5 mm² AWG 18 - 16
Diameter of individual strands ≥0.2mm
Conductor insulation material PVC, PP, TPE
Conductor diameter ≤2.8mm
Cable diameter 6 - 9 mm
Temperature range -25 °C … +85 °C
Temperature during connection -5 °C … +50 °C
Degree of protection IP67
Mating cycles 100
Recommended tightening torque 8 Nm
Electrical characteristics
Rated current 16 A
Rated voltage 230 V / 400 V
Rated impulse voltage 4 KV
Contact resistance 10mΩ
Insulation resistance 108Ω
Pollution degree 3
Overvoltage category 3
Isolation group 1
Materials
Contact material Copper alloy
Contact plating Gold
Contact carrier material TPU, PA
Housing material TPU, PA
Further information and data sheets see www.HARTING.com
0603
06
Further information and data sheets see www.HARTING.com
HARAX ® Panel feed-through
Technical characteristics Panel feed-throughCurrent carrying capacity The current carrying capacity is limited by maximum temperature of materials for inserts and contacts
including terminals. The current capacity-curve is valid for continuous, not interruptet current-loaded contacts of connectors when simultaneous power on all contacts is given, without exceeding the maximum temperature.
Control and test procedures according to DIN IEC 60 512-5.
Rat
ed c
urre
nt [A
]
Ambient temperature [oC]
Pg 13.5 3 poles
1 = Wire gauge 0.75 mm²
2 = Wire gauge 1.5 mm²
Rat
ed c
urre
nt [A
]
Ambient temperature [oC]
Pg 13.5 / M20 4 poles
1 = Wire gauge 0.75 mm²
2 = Wire gauge 1.5 mm²
0604
06
21 01 130 1013
21 01 130 1023
21 01 130 1223
21 01 130 3013
21 01 130 3023
21 01 130 3233
21 01 140 1023
21 01 140 3023
21 01 140 1323
21 01 140 3333
21 01 141 1023
21 01 141 3023
21 01 141 1323
21 01 141 3333
HARAX ® Pg 13.5 / M20 Panel feed-through
Identification Part No. Drawing Dimensions in mm
HARAX ® Pg 13.5 / 3 contacts with faston blades
HARAX ® Pg 13.5 / 3 contacts with solder termination
HARAX ® Pg 13.5 / 3 contacts with pre-assembled pigtail cable, I = 500 mm, 1.5 mm²
HARAX ® Pg 13.5 / 2 + PE with faston blades
HARAX ® Pg 13.5 / 2 + PE with solder termination
HARAX ® Pg 13.5 / 2 + PE with pre-assembled pigtail cable, I = 500 mm, 1.5 mm²
HARAX ® Pg 13.5 / 4 contacts with solder termination
HARAX ® Pg 13.5 / 3 + PE with solder termination
HARAX ® Pg 13.5 / 4 contacts with pre-assembled pigtail cable, l = 500 mm, 1.5 mm²
HARAX ® Pg 13.5 / 3 + PE with pre-assembled pigtail cable, l = 500 mm, 1.5 mm²
HARAX ® M20 / 4 contacts with solder termination
HARAX ® M20 / 3 + PE with solder termination
HARAX ® M20 / 4 contacts with pre-assembled pigtail cable, l = 500 mm, 1.5 mm²
HARAX ® M20 / 3 + PE with pre-assembled pigtail cable, l = 500 mm, 1.5 mm²
Further information and data sheets see www.HARTING.com
View: Mating side
View: Mating side
View: Mating side
View: Mating side
0605
06
21 01 010 0001
21 01 000 0008
21 01 000 0007
21 01 000 0039
21 01 010 0006
Further information and data sheets see www.HARTING.com
HARAX ® Panel feed-through Accessories
Identification Part No. Drawing Dimensions in mm
Termination element M12 HARAX ® Pg 9 3 contacts
Screw cap, splice ring, seal
Lock nut Pg 9
Lock nut Pg 13.5, SW 27
Lock nut Pg 13.5, SW 24
Termination element M12 HARAX ® Pg 9 4 contacts
Screw cap, splice ring, seal
0606
06
Notes
0701
07
M8 / M12 Circular connectors
Directory Page
7. INOX – Solutions for extreme demands
7.1 M12 INOX
o Technical characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 07.02
Cableconnectors • M12-LINOX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 07.04
0702
07
Technical characteristics M12 INOX
Specifications IEC 60 352-4 IEC 60 068-2-52:1996, severity level 4
Type M12 INOX V4A HARAX ® M12-L 4 poles M12 Crimp
General data
Conductor cross section 0.34 - 0.75 mm² AWG 22 - 18
0.14 - 0.75 mm² AWG 26 - 18
Diameter of individual strands ≥0.1mm X
Conductor insulation material PVC X
Conductor diameter 1.6 - 2.0 mm 2.0 - 2.6 mm 2.0 - 2.3 mm
Cable diameter 6 - 8 mm 4.5 - 8.8 mm
Temperature range -40 °C … +85 °C -40 °C … +85 °C
Temperature during connection -5 °C … +50 °C -5 °C … +50 °C
Degree of protection IP65 / IP67 IP67
Mating cycles 100 500
Tightening torque connector / hexagonal wrench 0.6 Nm / SW 17 0.6 Nm / SW 17
Electrical characteristics
Rated current 6 A 4 A
Rated voltage 50 V 250 V
Rated impulse voltage 1.5 kV 1.5 kV
Contact resistance 10mΩ 10mΩ
Insulation resistance 108Ω 108Ω
Pollution degree 3 3
Overvoltage category 3 3
Isolation group 1 1
Materials
Contact material Brass Brass
Contact plating Gold Gold
Contact carrier material PA unreinforced PA
Housing material V4A V4A
Further information and data sheets see www.HARTING.com
M12 INOX
0703
07
Technical characteristics M12 INOXCurrent carrying capacity The current carrying capacity is limited by maximum temperature of materials for inserts and contacts
including terminals. The current capacity-curve is valid for continuous, not interruptet current-loaded contacts of connectors when simultaneous power on all contacts is given, without exceeding the maximum temperature.
Control and test procedures according to DIN IEC 60 512-5.
Rat
ed c
urre
nt [A
]
Ambient temperature [oC]
M12-L 1 = Wire gauge 0.34 mm² 4 poles 2 = Wire gauge 0.75 mm²
Rat
ed c
urre
nt [A
]
Ambient temperature [oC]
M12, Crimp 1 = Wire gauge 0.34 mm² / 0.5 mm²
Further information and data sheets see www.HARTING.com
M12 INOX
0704
07
21 03 822 2535
21 03 222 2435
Further information and data sheets see www.HARTING.com
M12 INOX
Identification Part No. Drawing Dimensions in mm
M12-L Crimp INOX
HARAX ® M12-L INOX
Female, A-coding, straight version 5 poles
Female, A-coding, straight version 4 poles
•Designed for rough outdoor applications in harsh environments
•MaterialV4A
•Available with crimp resp. HARAX® rapid termination
•Extremerobustdesign,quickassembly
Applications / Advantages
Mating faces
A-coding 4 poles
A-coding 5 poles
Mating faces acc. to IEC 61 076-2-101
0705
07
21 03 882 1435
21 03 841 1535
Further information and data sheets see www.HARTING.com
M12 INOX
Identification Part No. Drawing Dimensions in mm
M12-L Crimp INOX
Male, D-coding, straight version 4 poles
Male, B-coding, straight version 5 poles
Mating faces
B-coding D-coding
Mating faces acc. to IEC 61 076-2-101
Be
09 47 220 0002 03.74 09 47 220 0002 03.77 09 47 220 0003 03.74 09 47 220 0003 03.77 09 47 220 0005 03.74 09 47 220 0005 03.77 09 47 220 0006 03.74 09 47 220 0006 03.77 09 47 220 0011 03.74 09 47 220 0011 03.77 09 47 220 0013 03.74 09 47 220 0013 03.77 09 47 220 0022 03.74 09 47 220 0022 03.77
09 47 222 2002 03.74 09 47 222 2002 03.77 09 47 222 2003 03.74 09 47 222 2003 03.77 09 47 222 2005 03.74 09 47 222 2005 03.77 09 47 222 2006 03.74 09 47 222 2006 03.77 09 47 222 2011 03.74 09 47 222 2011 03.77 09 47 222 2013 03.74 09 47 222 2013 03.77 09 47 222 2022 03.74 09 47 222 2022 03.77
09 47 800 0002 03.75 09 47 800 0002 03.77 09 47 800 0003 03.75 09 47 800 0003 03.77 09 47 800 0005 03.75 09 47 800 0005 03.77 09 47 800 0006 03.75 09 47 800 0006 03.77 09 47 800 0011 03.75 09 47 800 0011 03.77 09 47 800 0013 03.75 09 47 800 0013 03.77 09 47 800 0022 03.75 09 47 800 0022 03.77
09 47 808 0002 03.75 09 47 808 0002 03.77 09 47 808 0003 03.75 09 47 808 0003 03.77 09 47 808 0005 03.75 09 47 808 0005 03.77 09 47 808 0006 03.75 09 47 808 0006 03.77 09 47 808 0011 03.75 09 47 808 0011 03.77 09 47 808 0013 03.75 09 47 808 0013 03.77 09 47 808 0022 03.75 09 47 808 0022 03.77
09 48 220 0003 010 03.74 09 48 220 0003 015 03.74 09 48 220 0003 030 03.74 09 48 220 0003 050 03.74 09 48 220 0003 075 03.74 09 48 220 0003 100 03.74 09 48 220 0003 200 03.74 09 48 220 0004 010 03.74 09 48 220 0004 015 03.74 09 48 220 0004 030 03.74 09 48 220 0004 050 03.74
09 48 220 0004 075 03.74 09 48 220 0004 100 03.74 09 48 220 0004 200 03.74
09 48 222 2003 010 03.74 09 48 222 2003 015 03.74 09 48 222 2003 030 03.74 09 48 222 2003 050 03.74 09 48 222 2003 075 03.74 09 48 222 2003 100 03.74 09 48 222 2003 200 03.74 09 48 222 2004 010 03.74 09 48 222 2004 015 03.74 09 48 222 2004 030 03.74 09 48 222 2004 050 03.74 09 48 222 2004 075 03.74 09 48 222 2004 100 03.74 09 48 222 2004 200 03.74
09 48 800 0003 010 03.75 09 48 800 0003 015 03.75 09 48 800 0003 030 03.75 09 48 800 0003 050 03.75 09 48 800 0003 075 03.75 09 48 800 0003 100 03.75 09 48 800 0003 200 03.75 09 48 800 0004 010 03.75 09 48 800 0004 015 03.75 09 48 800 0004 030 03.75 09 48 800 0004 050 03.75 09 48 800 0004 075 03.75 09 48 800 0004 100 03.75 09 48 800 0004 200 03.75
09 48 808 0003 010 03.75 09 48 808 0003 015 03.75 09 48 808 0003 030 03.75 09 48 808 0003 050 03.75 09 48 808 0003 075 03.75 09 48 808 0003 100 03.75 09 48 808 0003 200 03.75 09 48 808 0004 010 03.75 09 48 808 0004 015 03.75 09 48 808 0004 030 03.75 09 48 808 0004 050 03.75 09 48 808 0004 075 03.75 09 48 808 0004 100 03.75 09 48 808 0004 200 03.75
09 67 000 3476 03.36 09 67 000 3476 03.60 09 67 000 3476 03.91 09 67 000 3576 03.36 09 67 000 3576 03.60 09 67 000 3576 03.91 09 67 000 5476 03.36 09 67 000 5476 03.60 09 67 000 5476 03.91 09 67 000 5576 03.36 09 67 000 5576 03.60 09 67 000 5576 03.91 09 67 000 8476 03.36 09 67 000 8476 03.60 09 67 000 8476 03.91 09 67 000 8576 03.36 09 67 000 8576 03.60 09 67 000 8576 03.91
09 99 000 0380 02.12 09 99 000 0382 03.36
09 99 000 0382 03.60 09 99 000 0384 03.36 09 99 000 0384 03.60 09 99 000 0384 03.91 09 99 000 0395 05.12 09 99 000 0501 03.36 09 99 000 0501 03.60 09 99 000 0501 03.91 09 99 000 0501 04.13 09 99 000 0525 04.13 09 99 000 0531 03.36 09 99 000 0531 03.60 09 99 000 0531 03.91 09 99 000 0646 03.36 09 99 000 0646 03.91 09 99 000 0646 04.13
20 82 000 0001 03.71 20 82 000 0003 03.71 20 82 000 1210 03.71 20 82 000 9901 03.71
20 82 005 1214 03.71
21 01 000 0003 03.37 21 01 000 0003 03.60 21 01 000 0003 03.92 21 01 000 0003 04.14 21 01 000 0007 06.05 21 01 000 0008 06.05 21 01 000 0018 03.37 21 01 000 0018 03.62 21 01 000 0018 03.91 21 01 000 0018 04.13 21 01 000 0020 05.12 21 01 000 0030 03.38 21 01 000 0030 03.61 21 01 000 0030 03.92 21 01 000 0030 04.14 21 01 000 0031 03.38 21 01 000 0031 03.61 21 01 000 0031 03.92 21 01 000 0031 04.14 21 01 000 0033 03.38 21 01 000 0033 03.61 21 01 000 0033 03.92 21 01 000 0033 04.14 21 01 000 0036 03.85 21 01 000 0036 04.08 21 01 000 0038 03.38 21 01 000 0038 03.61 21 01 000 0038 03.92 21 01 000 0038 04.14 21 01 000 0039 06.05
21 01 010 0001 06.05 21 01 010 0006 06.05 21 01 010 2001 03.37 21 01 010 2005 02.12 21 01 010 2007 03.37 21 01 010 2007 03.62 21 01 010 2008 02.12 21 01 010 2011 03.37 21 01 010 2013 02.12 21 01 010 2015 03.37 21 01 010 2015 03.62 21 01 010 2016 02.12 21 01 010 2017 03.37
21 01 010 2017 03.62 21 01 010 2017 03.91
21 01 100 9014 04.13 21 01 100 9019 04.13
21 01 130 1013 06.04 21 01 130 1023 06.04 21 01 130 1223 06.04 21 01 130 3013 06.04 21 01 130 3023 06.04 21 01 130 3233 06.04
21 01 140 1023 06.04 21 01 140 1323 06.04 21 01 140 3023 06.04 21 01 140 3333 06.04 21 01 140 5081 03.10 21 01 140 5091 03.11
21 01 141 1023 06.04 21 01 141 1323 06.04 21 01 141 3023 06.04 21 01 141 3333 06.04
21 02 151 1305 02.06 21 02 151 1405 02.06 21 02 151 2305 02.07 21 02 151 2405 02.07
21 02 159 1305 02.05
21 02 454 5301 02.09 21 02 454 5301 02.10 21 02 454 5302 02.09 21 02 454 5302 02.10 21 02 454 5303 02.09 21 02 454 5303 02.10 21 02 454 5304 02.09 21 02 454 5304 02.10 21 02 454 5305 02.09 21 02 454 5305 02.10 21 02 454 7301 02.09 21 02 454 7301 02.10 21 02 454 7302 02.09 21 02 454 7302 02.10 21 02 454 7303 02.09 21 02 454 7303 02.10 21 02 454 7304 02.09 21 02 454 7304 02.10 21 02 454 7305 02.09 21 02 454 7305 02.10
21 02 554 4301 02.09 21 02 554 4301 02.11 21 02 554 4302 02.09 21 02 554 4302 02.11 21 02 554 4303 02.09 21 02 554 4303 02.11 21 02 554 4304 02.09 21 02 554 4304 02.11 21 02 554 4305 02.09 21 02 554 4305 02.11 21 02 554 7301 02.09 21 02 554 7301 02.11 21 02 554 7302 02.09 21 02 554 7302 02.11 21 02 554 7303 02.09 21 02 554 7303 02.11 21 02 554 7304 02.09 21 02 554 7304 02.11
21 02 554 7305 02.09 21 02 554 7305 02.11
21 03 030 1300 03.62 21 03 030 1400 03.36
21 03 111 1405 03.08 21 03 111 2405 03.09
21 03 112 1405 03.08 21 03 112 2405 03.09
21 03 121 1801 03.14 21 03 121 2801 03.15
21 03 212 1305 03.12 21 03 212 1306 03.12 21 03 212 1400 03.12 21 03 212 1407 03.12 21 03 212 2305 03.13 21 03 212 2306 03.13 21 03 212 2400 03.13 21 03 212 2407 03.13
21 03 221 1405 03.14 21 03 221 2405 03.15
21 03 222 2435 07.04
21 03 241 1301 03.42 21 03 241 2301 03.43
21 03 272 1505 03.12 21 03 272 2505 03.13
21 03 281 1405 03.66 21 03 281 2405 03.67
21 03 282 1405 03.66 21 03 282 2405 03.67
21 03 301 1000 03.34 21 03 301 1000 03.58 21 03 301 1000 03.89 21 03 301 1001 03.34 21 03 301 1001 03.58 21 03 301 1001 03.89 21 03 301 2000 03.35 21 03 301 2000 03.59 21 03 301 2000 03.90 21 03 301 2000 04.11 21 03 301 2001 03.35 21 03 301 2001 03.59 21 03 301 2001 03.90 21 03 301 2001 04.11
21 03 311 1402 03.30 21 03 311 1501 03.30 21 03 311 2400 03.31 21 03 311 2501 03.31 21 03 311 2801 03.33
21 03 321 1410 03.32 21 03 321 1420 03.32 21 03 321 1425 03.26 21 03 321 1510 03.32 21 03 321 1518 03.34 21 03 321 1520 03.32
List of part numbers
Part No. Page Part No. Page Part No. Page Part No. Page Part No. Page
Be
21 03 321 1818 03.34 21 03 321 2425 03.27 21 03 321 2518 03.35 21 03 321 2818 03.35 21 03 321 6410 03.33 21 03 321 6420 03.33 21 03 321 6510 03.33 21 03 321 6520 03.33 21 03 321 9400 03.36
21 03 330 1300 03.54
21 03 339 1301 03.54 21 03 339 2301 03.55
21 03 341 1425 03.50 21 03 341 1505 03.56 21 03 341 1518 03.58 21 03 341 2425 03.51 21 03 341 2505 03.57 21 03 341 2518 03.59 21 03 341 6401 03.62
21 03 371 1400 03.86 21 03 371 1403 03.82 21 03 371 1420 03.84 21 03 371 2403 03.83 21 03 371 2415 03.87
21 03 381 1418 03.89 21 03 381 1425 03.78 21 03 381 2400 03.84 21 03 381 2401 03.84 21 03 381 2418 03.90 21 03 381 2425 03.79 21 03 381 2800 04.07 21 03 381 2801 04.12 21 03 381 2802 04.09 21 03 381 2803 04.09 21 03 381 2804 04.10 21 03 381 2805 04.10 21 03 381 2806 04.11 21 03 381 2807 04.11 21 03 381 2809 04.10 21 03 381 4400 03.84 21 03 381 4401 03.84 21 03 381 4410 03.88 21 03 381 4411 03.88 21 03 381 4412 03.88 21 03 381 4413 03.88 21 03 381 4430 03.88 21 03 381 4432 03.88 21 03 381 4800 04.07 21 03 381 4802 04.09 21 03 381 4804 04.10 21 03 381 6401 03.85 21 03 381 6405 03.85 21 03 381 6410 03.87 21 03 381 6420 03.87 21 03 381 6815 04.08
21 03 415 2401 03.21 21 03 415 2401 03.23 21 03 415 2402 03.21 21 03 415 2402 03.23 21 03 415 2403 03.21 21 03 415 2403 03.23 21 03 415 2404 03.21 21 03 415 2404 03.23 21 03 415 2405 03.21 21 03 415 2405 03.23 21 03 415 5401 03.21
21 03 415 5401 03.23 21 03 415 5402 03.21 21 03 415 5402 03.23 21 03 415 5403 03.21 21 03 415 5403 03.23 21 03 415 5404 03.21 21 03 415 5404 03.23 21 03 415 5405 03.21 21 03 415 5405 03.23 21 03 415 7401 03.21 21 03 415 7401 03.23 21 03 415 7402 03.21 21 03 415 7402 03.23 21 03 415 7403 03.21 21 03 415 7403 03.23 21 03 415 7404 03.21 21 03 415 7404 03.23 21 03 415 7405 03.21 21 03 415 7405 03.23
21 03 449 4301 03.47 21 03 449 4301 03.49 21 03 449 4302 03.47 21 03 449 4302 03.49 21 03 449 4303 03.47 21 03 449 4303 03.49 21 03 449 4304 03.47 21 03 449 4304 03.49 21 03 449 4305 03.47 21 03 449 4305 03.49 21 03 449 6301 03.47 21 03 449 6301 03.49 21 03 449 6302 03.47 21 03 449 6302 03.49 21 03 449 6303 03.47 21 03 449 6303 03.49 21 03 449 6304 03.47 21 03 449 6304 03.49 21 03 449 6305 03.47 21 03 449 6305 03.49
21 03 483 1801 04.06 21 03 483 1803 04.06 21 03 483 1805 04.06 21 03 483 1807 04.06 21 03 483 1810 04.06 21 03 483 5801 04.06 21 03 483 5802 04.06 21 03 483 5850 04.06 21 03 483 5851 04.06 21 03 483 5852 04.06
21 03 485 1401 03.74 21 03 485 1401 03.76 21 03 485 1403 03.74 21 03 485 1403 03.76 21 03 485 1405 03.74 21 03 485 1405 03.76 21 03 485 1410 03.74 21 03 485 1410 03.76 21 03 485 1420 03.74 21 03 485 1420 03.76 21 03 485 1451 03.74 21 03 485 1451 03.76 21 03 485 1457 03.74 21 03 485 1457 03.76 21 03 485 3401 03.75 21 03 485 3401 03.76 21 03 485 3403 03.75 21 03 485 3403 03.76 21 03 485 3405 03.75 21 03 485 3405 03.76 21 03 485 3410 03.75
21 03 485 3410 03.76 21 03 485 3420 03.75 21 03 485 3420 03.76 21 03 485 3451 03.75 21 03 485 3451 03.76 21 03 485 3457 03.75 21 03 485 3457 03.76
21 03 514 1801 03.22 21 03 514 1801 03.25 21 03 514 1803 03.22 21 03 514 1803 03.25 21 03 514 1805 03.22 21 03 514 1805 03.25
21 03 515 4401 03.21 21 03 515 4401 03.24 21 03 515 4402 03.21 21 03 515 4402 03.24 21 03 515 4403 03.21 21 03 515 4403 03.24 21 03 515 4404 03.21 21 03 515 4404 03.24 21 03 515 4405 03.21 21 03 515 4405 03.24 21 03 515 7401 03.21 21 03 515 7401 03.24 21 03 515 7402 03.21 21 03 515 7402 03.24 21 03 515 7403 03.21 21 03 515 7403 03.24 21 03 515 7404 03.21 21 03 515 7404 03.24 21 03 515 7405 03.21 21 03 515 7405 03.24
21 03 549 1301 03.47 21 03 549 1301 03.48 21 03 549 1302 03.47 21 03 549 1302 03.48 21 03 549 1303 03.47 21 03 549 1303 03.48 21 03 549 1304 03.47 21 03 549 1304 03.48 21 03 549 1305 03.47 21 03 549 1305 03.48 21 03 549 2301 03.47 21 03 549 2301 03.49 21 03 549 2302 03.47 21 03 549 2302 03.49 21 03 549 2303 03.47 21 03 549 2303 03.49 21 03 549 2304 03.47 21 03 549 2304 03.49 21 03 549 2305 03.47 21 03 549 2305 03.49 21 03 549 3301 03.47 21 03 549 3301 03.48 21 03 549 3302 03.47 21 03 549 3302 03.48 21 03 549 3303 03.47 21 03 549 3303 03.48 21 03 549 3304 03.47 21 03 549 3304 03.48 21 03 549 3305 03.47 21 03 549 3305 03.48 21 03 549 4301 03.47 21 03 549 4301 03.49 21 03 549 4302 03.47 21 03 549 4302 03.49 21 03 549 4303 03.47 21 03 549 4303 03.49 21 03 549 4304 03.47
21 03 549 4304 03.49 21 03 549 4305 03.47 21 03 549 4305 03.49
21 03 585 1401 03.74 21 03 585 1401 03.76 21 03 585 1403 03.74 21 03 585 1403 03.76 21 03 585 1405 03.74 21 03 585 1405 03.76 21 03 585 1410 03.74 21 03 585 1410 03.76 21 03 585 1420 03.74 21 03 585 1420 03.76 21 03 585 1451 03.74 21 03 585 1451 03.76 21 03 585 1457 03.74 21 03 585 1457 03.76 21 03 585 3401 03.75 21 03 585 3401 03.76 21 03 585 3403 03.75 21 03 585 3403 03.76 21 03 585 3405 03.75 21 03 585 3405 03.76 21 03 585 3410 03.75 21 03 585 3410 03.76 21 03 585 3420 03.75 21 03 585 3420 03.76 21 03 585 3451 03.75 21 03 585 3451 03.76 21 03 585 3457 03.75 21 03 585 3457 03.76
21 03 812 1405 03.16 21 03 812 1505 03.16 21 03 812 2405 03.18 21 03 812 2505 03.18
21 03 821 1505 03.16
21 03 822 1425 03.28 21 03 822 1525 03.28 21 03 822 2425 03.29 21 03 822 2525 03.29 21 03 822 2535 07.04 21 03 822 3505 03.17 21 03 822 4505 03.19
21 03 841 1505 03.44 21 03 841 1525 03.52 21 03 841 1535 07.05 21 03 841 2505 03.45 21 03 841 2525 03.53
21 03 881 1405 03.69 21 03 881 1805 04.05 21 03 881 5805 04.05
21 03 882 1405 03.68 21 03 882 1415 03.68 21 03 882 1425 03.80 21 03 882 1435 07.05 21 03 882 2405 03.70 21 03 882 2425 03.81 21 03 882 3405 03.69
21 04 116 1505 05.04 21 04 116 2505 05.05
21 04 316 1305 05.10 21 04 316 1505 05.10 21 04 316 2400 05.11 21 04 316 2505 05.11
21 04 416 1501 05.07 21 04 416 1501 05.09 21 04 416 1502 05.07 21 04 416 1502 05.09 21 04 416 1503 05.07 21 04 416 1503 05.09 21 04 416 1504 05.07 21 04 416 1504 05.09 21 04 416 1505 05.07 21 04 416 1505 05.09 21 04 416 3501 05.07 21 04 416 3501 05.09 21 04 416 3502 05.07 21 04 416 3502 05.09 21 04 416 3503 05.07 21 04 416 3503 05.09 21 04 416 3504 05.07 21 04 416 3504 05.09 21 04 416 3505 05.07 21 04 416 3505 05.09
21 04 516 1402 05.08 21 04 516 2302 05.08 21 04 516 2501 05.07 21 04 516 2501 05.09 21 04 516 2502 05.07 21 04 516 2502 05.09 21 04 516 2503 05.07 21 04 516 2503 05.09 21 04 516 2504 05.07 21 04 516 2504 05.09 21 04 516 2505 05.07 21 04 516 2505 05.09 21 04 516 4501 05.07 21 04 516 4501 05.09 21 04 516 4502 05.07 21 04 516 4502 05.09 21 04 516 4503 05.07 21 04 516 4503 05.09 21 04 516 4504 05.07 21 04 516 4504 05.09 21 04 516 4505 05.07 21 04 516 4505 05.09
21 83 515 4401 03.21 21 83 515 4401 03.25 21 83 515 4402 03.21 21 83 515 4402 03.25 21 83 515 4403 03.21 21 83 515 4403 03.25 21 83 515 4404 03.21 21 83 515 4404 03.25 21 83 515 4405 03.21 21 83 515 4405 03.25 21 83 515 7401 03.21 21 83 515 7401 03.25 21 83 515 7402 03.21 21 83 515 7402 03.25 21 83 515 7403 03.21 21 83 515 7403 03.25 21 83 515 7404 03.21 21 83 515 7404 03.25 21 83 515 7405 03.21 21 83 515 7405 03.25
List of part numbers
Part No. Page Part No. Page Part No. Page Part No. Page Part No. Page
HARTING Interface Connectors
People | Power | Partnership
HARTING Industrial Connectors Han®
People | Power | Partnership
HARTING
19 6
People | Power | Partnership
Intelligente Netzwerk-Lösungen
HARTING Coaxial and Metric Connectors
People | Power | Partnership
HARTING Device Connectivity DeviceCon
People | Power | Partnership
HARTING
People | Power | Partnership
35 2
TCA Connectors
HARTING DIN 41 612
People | Power | Partnership
08_9761+9762_HA_Applikationsbros1 1 05.03.2008 12:05:45
Interface Connectors Industrial Connectors Han®
Connectors DIN 41 612
Intelligent Network Solutions
Coaxial and Metric Connectors
Application brochure
TCA Connectors High Speed Backplanes
Sender:
Company:
Department:
Name:
Prename:
Function:
Street:
Postcode/Town:
Country:
Phone:
Fax:
E-Mail:Please send it by post or fax to your local HARTING representatives (see page addresses) or visit us under www.HARTING.com.
Catalogue order information
Please send me further information:
Device Connectivity
Sales Network – worldwide
Afghanistan see United Arab EmiratesAlbania see Eastern EuropeArgentina Condelectric S.A. Hipólito Yrigoyen 2591, 1640 - Martínez Buenos Aires – Argentina Phone +54 11 4836 1053 Fax +54 11 4836 1053 [email protected] see Eastern EuropeAustralia HARTING Pty Ltd Suite 11 / 2 Enterprise Drive Bundoora 3083, AUS-Victoria Phone +61 3 9466 7088 Fax +61 3 9466 7099 [email protected] www.HARTING.com.auAustria HARTING Ges.m.b.H. Deutschstraße 19, A-1230 Wien Phone +431 6162121 Fax +431 6162121-21 [email protected] www.HARTING.atAzerbaijan see Eastern EuropeBahrain see United Arab Emirates
Belgium HARTING N.V./S.A. Z.3 Doornveld 23, B-1731 Zellik Phone +32 2 466 0190 Fax +32 2 466 7855 [email protected] www.HARTING.be
Bosnia and Herzegovina see Eastern Europe
Brazil HARTING Ltda. Rua Major Paladino 128 – Prédio 11 CEP 05307-000 – São Paulo – SP – Brasil Phone +55 11 5035 0073 Fax +55 11 5034 4743 [email protected] www.HARTING.com.br
Brunei see Singapore
Bulgaria see Eastern Europe
Canada HARTING Canada Inc. 8455 Trans-Canada Hwy., Suite 202 St.Laurent,QC,H4S1Z1,Canada Phone 855-659-6653 Fax 855-659-6654 [email protected] www.HARTING.ca
China HARTING (Zhuhai) Manufacturing Co., Ltd. Shanghai Branch, Room 3501- 3503, No.1,HongQiaoRoad,GrandGatewayI Xu Hui District, Shanghai 200030, China Phone +86 21 6386 2200 Fax +86 21 6386 8636 [email protected] www.HARTING.com.cn
Croatia see Eastern Europe
Czech Republic HARTING s.r.o. Mlýnská 2, CZ-160 00 Praha 6 Phone +420 220 380 460 Fax +420 220 380 461 [email protected] www.HARTING.cz
Denmark HARTING ApS Hjulmagervej 4a DK - 7100 Vejle Phone +45 70 25 00 32 Fax +45 75 80 64 99 [email protected] www.HARTING.dk
Tochtergesellschaft / Local subsidiaryFertigungsstätte / Production PlantF & E / R & D
Sales Network – worldwide
Eastern Europe HARTING Eastern Europe GmbH Bamberger Straße 7 D-01187 Dresden Phone +49 351 4361 760 Fax +49 351 436 1770 [email protected] www.HARTING.com
Egypt see United Arab Emirates
Estonia see Eastern Europe
Finland HARTING Oy Teknobulevardi 3-5 FI-01530 Vantaa Phone +358 207 291 510 Fax +358 207 291 511 [email protected] www.HARTING.fi
France HARTING France 181 avenue des Nations, Paris Nord 2 BP 66058 Tremblay en France F-95972 Roissy Charles de Gaulle Cédex Phone +33 1 4938 3400 Fax +33 1 4863 2306 [email protected] www.HARTING.fr
Germany HARTING Deutschland GmbH & Co. KG P.O. Box 2451, D-32381 Minden Simeonscarré 1, D-32427 Minden Phone +49 571 8896 0 Fax +49 571 8896 282 [email protected] www.HARTING.de
Georgia see Eastern Europe
Great Britain HARTING Ltd., Caswell Road Brackmills Industrial Estate GB-Northampton, NN4 7PW Phone +44 1604 827 500 Fax +44 1604 706 777 [email protected] www.HARTING.co.uk
Hong Kong HARTING (HK) Limited Regional Office Asia Pacific 3512 Metroplaza Tower 1 223 Hing Fong Road Kwai Fong, N. T., Hong Kong Phone +852 2423 7338 Fax +852 2480 4378 [email protected] www.HARTING.com.hk
Hungary HARTING Magyarország Kft. Fehérvári út 89-95, H-1119 Budapest Phone +36 1 205 34 64 Fax +36 1 205 34 65 [email protected] www.HARTING.hu
India HARTING India Pvt Ltd 7th Floor (West Wing), Central Square II Unit No.B-19 Part, B 20&21 TVK Industrial Estate Guindy, Chennai - 600032 Phone +91-44-43560415 +91-44-43456262 Fax +91-44-43560417 [email protected] http://www.HARTING.in
Indonesia see Malaysia
Iran see United Arab Emirates
Iraq see United Arab Emirates
Israel COMTEL Israel Electronic Solutions Ltd. Bet Hapamon, 20 Hataas st. P.O.Box 66 Kefar-Saba 44425 Phone +972-9-7677240 Fax +972-9-7677243 [email protected] www.comtel.co.il
Italy HARTING SpA Via Dell‘ Industria 7 I-20090 Vimodrone (Milano) Phone +39 02 250801 Fax +39 02 2650 597 [email protected] www.HARTING.it
Japan HARTING K. K. Yusen Shin-Yokohama 1 Chome Bldg., 2F 1-7-9, Shin-Yokohama, Kohoku Yokohama 222-0033 Japan Phone +81 45 476 3456 Fax +81 45 476 3466 [email protected] www.HARTING.co.jp
Jemen see United Arab Emirates
Jordan see United Arab Emirates
Kazakhstan see Eastern Europe
Kirghizia see Eastern Europe
Korea (South) HARTING Korea Limited #308 Yatap Leaders Building 342-1, Yatap-dong, Bundang-gu Sungnam-City, Kyunggi-do 463-828, Republic of Korea Phone +82 31 781 4615 Fax +82 31 781 4616 [email protected] www.HARTING.co.kr
Kosovo see Eastern Europe
Kuwait see United Arab Emirates
Latvia see Eastern Europe
Lebanon see United Arab Emirates
Lithuania see Eastern Europe
Macedonia see Eastern Europe
Malaysia (Office) HARTING Singapore Pte Ltd Malaysia Branch 11-02 Menara Amcorp Jln. Persiaran Barat 46200 PJ, Sel. D. E., Malaysia Phone +60 3 / 7955 6173 Fax +60 3 / 7955 5126 [email protected]
Montenegro see Eastern Europe
Netherlands HARTING B.V. Larenweg 44 NL-5234 KA ‚s-Hertogenbosch Postbus 3526 NL-5203 DM ‚s-Hertogenbosch Phone +31 736 410 404 Fax +31 736 440 699 [email protected] www.HARTINGbv.nl
New Zealand see Australia
Norway HARTING A/S Østensjøveien 36, N-0667 Oslo Phone +47 22 700 555 Fax +47 22 700 570 [email protected] www.HARTING.no
Oman see United Arab Emirates
Pakistan see United Arab Emirates
Philippines see Malaysia
Sales Network – worldwide
Poland HARTING Polska Sp. z o. o ul.Duńska9 PL-54-427Wrocław Phone +48 71 352 81 71 Fax +48 71 350 42 13 [email protected] www.HARTING.pl
Portugal HARTING Iberia, S. A. Avda. Josep Tarradellas 20-30 4o 6a E-08029 Barcelona Phone +351 219 673 177 Fax +351 219 678 457 [email protected] www.HARTING.es/pt
Qatar see United Arab Emirates
Republic of Moldova see Eastern Europe
Romania HARTING Romania SCS Europa Unita str. 21 550018-Sibiu, Romania Phone +40 369-102 671 Fax +40 369-102 622 [email protected] www.HARTING.com
Russia HARTING ZAO Maliy Sampsoniyevsky prospect 2A 194044 Saint Petersburg, Russia Phone +7 812 327 6477 Fax +7 812 327 6478 [email protected] www.HARTING.ru
Saudi Arabia see United Arab Emirates
Serbia see Eastern Europe
Singapore HARTING Singapore Pte Ltd. 25 International Business Park #04-108 German Centre Singapore 609916 Phone +65 6225 5285 Fax +65 6225 9947 [email protected] www.HARTING.sg
Slovakia HARTING s.r.o. Sales office Slovakia J. Simora 5, SK - 940 52 Nové Zámky Phone +421 356-493 993 Fax +421 356-402 114 [email protected] www.HARTING.sk
Slovenia see Eastern Europe
South Africa HARTING South Africa (Pty) Ltd Ground Floor, Twickenham Building PO Box 67302 Johannesburg (Bryanston) 2021, South Africa Phone +27 (0) 11 575 0017 Fax +27 (0) 11 576 6000 [email protected] www.HARTING.co.za
Spain HARTING Iberia S.A. Avda. Josep Tarradellas 20-30 4o 6a E-08029 Barcelona Phone +34 93 363 84 75 Fax +34 93 419 95 85 [email protected] www.HARTING.es
Sweden HARTING AB Gustavslundsvägen 141 B 4tr S-167 51 Bromma Phone +46 8 445 7171 Fax +46 8 445 7170 [email protected] www.HARTING.se
Switzerland HARTING AG Industriestrasse 26 CH-8604 Volketswil Phone +41 44 908 20 60 Fax +41 44 908 20 69 [email protected] www.HARTING.ch
Syria see United Arab Emirates
Taiwan HARTING Taiwan Ltd. Room 1, 5/F 495 GuangFu South Road RC-110 Taipei, Taiwan Phone +886 2 2758 6177 Fax +886 2 2758 7177 [email protected] www.HARTING.com.tw
Tajikistan see Eastern Europe
Thailand see Malaysia
Turkey HARTINGTURKEIElektronikLtd.Şti. Barbaros Mah. Dereboyu Cad. FesleğenSok. Uphill Towers, A-1b Kat:8 D:45 34746Ataşehir,İstanbul Phone +90 216 688 81 00 Fax +90 216 688 81 01 [email protected] www.HARTING.com.tr
Turkmenistan see Eastern Europe
Ukraine see Eastern Europe
United Arab Emirates HARTING Middle East FZ-LLC Knowledge Village, Block 2A, Office F72 P.O. Box 454372, Dubai United Arab Emirates Phone +971 4 453 9737 Fax +971 4 439 0339 [email protected] www.HARTING.ae
USA HARTING Inc. of North America 1370 Bowes Road USA-Elgin, Illinois 60123 Phone +1 (877) 741-1500 (toll free) Fax +1 (866) 278-0307 (Inside Sales) [email protected] www.HARTING-USA.com
Uzbekistan see Eastern Europe
Vietnam see Singapore
Distributors – worldwide
Digi-Key Corporation: www.digikey.com
Farnell: www.farnell.com
FUTURE Electronics: www.futureelectronics.com
Mouser Electronics: www.mouser.com
RS Components: www.rs-components.com
Other countries and general contact
HARTING Electronics GmbH P.O. Box 1433 32328 Espelkamp - Germany Phone +49 5772/47-97200 Fax +49 5772/47-777 [email protected]
www.HARTING.aewww.HARTING.atwww.HARTING.com.auwww.HARTING.bewww.HARTING.com.brwww.HARTING.cawww.HARTING.chwww.HARTING.com.cnwww.HARTING.czwww.HARTING.dewww.HARTING.dkwww.HARTING.eswww.HARTING-easterneurope.comwww.HARTING.fiwww.HARTING.frwww.HARTING.co.ukwww.HARTING.com.hkwww.HARTING.huwww.HARTING.co.inwww.HARTING.itwww.HARTING.co.jpwww.HARTING.co.krwww.HARTINGbv.nlwww.HARTING.nowww.HARTING.plwww.HARTING.ptwww.HARTING.rowww.HARTING.ruwww.HARTING.sewww.HARTING.sgwww.HARTING.skwww.HARTING.com.trwww.HARTING.com.twwww.HARTING-USA.comwww.HARTING.co.za
MO/
2012
-05-
03/3
.0
98 4
2 91
8 02
01
Vers
ion
18 5
HARTING Technology [email protected]