Gun Control Unit - Moog, Inc. · Gun Control Unit GUN CONTROL UNIT_ Moog’s gun control unit is...
Embed Size (px)
Transcript of Gun Control Unit - Moog, Inc. · Gun Control Unit GUN CONTROL UNIT_ Moog’s gun control unit is...

Gun Control Unit
GUN CONTROL UNIT_
Moog’s gun control unit is the most advanced, processor controlled system available for the military’s gun and cannon platforms. This GCU is designed and qualified to MIL-STD-810, MIL-STD-108 and MIL-STD-461/464 requirements. It is also Weapon Systems & Explosive Safety Review Board (WSESRB) certified. It’s first application was for the BAE/Rafael Mk38 Mod 2 remote weapon station for the US Navy. It can easily be modified or upgraded for other gun and cannon applications.
GCU Features• Free-air convection cooled to +71˚C with 500 amps
peak and 250 amps continuous gun motor drive. Higher current drive systems readily accommodated
• Multiple communication bus options available• Performs full diagnostics (BIT) on GCU, cannon and
portions of the weapon station
• Aluminum enclosure and cover. MIL-STD-C-5541/53072 conversion/CARC coatings. Fully sealed and NBC decontamination
• Multiple enclosure and mounting options available

Form 500-719 1010
East Aurora, NY 14052 USA+1.716.652.2000 www.moog.com
© 2010 Moog, Inc . A l l r i gh ts reser ved .
GUN CONTROL UNIT_GUN CONTROL UNIT_
Specifications
DC input voltage 28V per MIL-STD-1275C and MIL-STD-704F
Transient voltages (single fault) 100V surge, 250V spikesReverse voltage protected
EMI/EMC/E3MIL-STD-461E: CE102, CS101, CS114, CS115, cS116, RE102, RS103 MIL-STD-464: lightening, electrical bonding and grounding, upgradeable
for TEMPEST Nuclear weapons INR/EMP hardening, optional
Environmental (MIL-STD-810F)
Temperature: Method 501.4 P-I, Storage, Tst = -51˚ C to 85˚CP-II, Operation, Top = -40˚C to 71˚C
Vibration: Method 514.5 Cat-24, Minimum Integrity Test Vehicle
Shock: Method 516.5-8 40g, 7.5ms
Humidity: Method 507.4 5 cycles, 95% RH
Salt Fog: Method 509.4 5%, 48 hours
Sand & Dust: Method 510.4 P-I and P-II, 6 hrs
Fungus: Method 508.5 28 days
Altitude: Method 500.4 P-I, non-operation; P-II, operation; P-III, rapid decompression
Immersion MIL-STD-108E, Procedure 4.13, 1m, 1 hr
Cleaning 10 gpm, 25"ø nozzle, 1 ft ┴ to LRU
Mechanical
Dimensions (LxWxH) 13" x 8" x 4"
Weight < 16 lbs