Guardhouses and Security Booths. Security Station Floor Plan.

22
Guardhouses and Security Booths

Transcript of Guardhouses and Security Booths. Security Station Floor Plan.

Page 1: Guardhouses and Security Booths. Security Station Floor Plan.

Guardhouses and Security Booths

Page 2: Guardhouses and Security Booths. Security Station Floor Plan.

Security Station Security Station Floor PlanFloor Plan

Page 3: Guardhouses and Security Booths. Security Station Floor Plan.

8’ x 8’ – (with or without a trailer)

D

4F2

3030 VERTICALSLIDER (TYP. 6)

2630 VERTICALSLIDER

HVAC UNITMTD. UNDERWINDOW

SHEET VINYLFLOOR COVERING

7'-9"

7'-9

"

FLOOR PLANSCALE: 1/4" = 1'-0"

1

3068 STEEL CLAD WITHKL, GLASS LITE, WIND CHAINAND WOOD JAMB

PC

PANEL MTD.UNDERWINDOW

Page 4: Guardhouses and Security Booths. Security Station Floor Plan.

8’ x 8’ SPECIFICATIONSSTEEL SIDING: TENSILE STRENGTH / MINIMUM

YIELD STRENGTH: 55 KSI

2 x4 SYP #3 OR BETTER @ 16" O.C.

COPPER ROMEX OR NM, NMC, NMSNOTE: CONDUIT TO BE STUBBED THRU WALL /

FLOOR FROM PANEL FOR CONNECTIONBY OWNER TO EXISTING SERVICE.

ROOF:

SIDING:

APPLIED:

CEILING:

EXTERIOR TRIM:

DOORS & WINDOWS:

ELECTRICAL:

ELECTRICAL FIXTURES:

MATERIAL: COLOR: T.B.D.

{ REFER TO DOOR & WINDOW SCHEDULE}

{REFER TO ELECTRICAL PLAN}

LINING:

FOUNDATION:

FLOOR:

BLOCKING & LEVELING BY MORGAN MORGAN WILL UTILIZE TRAILER

JACKS WITH MOUNTING PLATES FORSTABILIZATION OF THE UNIT.

ANY CONCRETE SLAB, GRADE BEAMOR CONCRETE PIERS / FOOTINGSSHALL BE BY OTHERS.

EXTERIOR WALLS:

HVAC:

UNDERSHEATHING: NONE

ROAD LEGAL TRAILER WITH 4-WAY PLUG, 12 GA. GRATEPLATFORM, WITH 1" X 1" SAFETY RAILS.

2" BALL COUPLER WITH HITCH & SAFETY CHAINS ANDRUNNING LIGHTS.

MANUAL PULL OUT STEPS WITH 7" DROP/RISE, 24" WIDE.POWDER COATED BLACK TO MATCH TRAILER FRAME.

OPTIONS AVAILABLE, SUCH AS 5500 WATT GENERATOREQUIPPED, DUAL FUEL ELECTRIC START.

SINGLE JOISTS: SIDEBANDS: SINGLE

DECKING: 5/8" OR BETTER PLYWOOD or ENG.WOOD GLUED & NAILED TO JOIST

ENDBANDS: SINGLE

MATERIAL:

TPO OVER 12" O.S.B..25 VERTICAL RISE PEREVERY 12" RUN

PERMITS: TRANSPORTATION BY MORGAN ALL OTHER BY OWNER

STUDS: 2x4 SYP #3 OR BETTER @ 24" O.C. STUD & CEILING HEIGHT: REFER TO CROSS SECTION

ROOF: R-11 EXTERIOR WALLS: R-11 PARTITION WALLS: R-11 (OPTIONAL) FLOOR: R-11

1/2" VINYL GYPSUM

T.B.D.

STYLE:

ROOFING MATERIAL: PITCH:

ROOF MEMBERS:

MATERIAL:

INSULATION:

FLOOR COVERING: SHEET VINYL ROLL GOODS

VERTICAL

FLAT

PRE PAINTED STEEL

COLOR:

NOTES: DOUBLE STUDS AND HEADERS ATEXTERIOR OPENINGS OVER 48-3/4" AND INTERIORLOAD BEARING WALLS WHERE APPLICABLE.

THRU THE WALL HVAC UNITS OROPTIONAL ROOF MOUNTED UNITS.

2x4 #2 SYP @ 24" O.C.

CLASS A FINISH 1/2" PREDECKCEILING BOARD SUPPORTED BYROSETTES UNDER ROOF MEMBERS

PARTITION WALLS: STUDS: 2x4 SYP #3 OR BETTER @ 24" O.C.

NOTES: DOUBLE STUDS AND HEADERS AT INTERIOROPENINGS OVER 48-3/4" AND INTERIOR LOADBEARING WALLS WHERE APPLICABLE.

PRE PAINTED STEEL (MIN THICKNESS0.0149") OVER WATER-RESISTIVE BARRIER

TRAILER CHASSIS:

SHEATHING: AVAILABLE IN HIGH WIND AREAS.

Page 5: Guardhouses and Security Booths. Security Station Floor Plan.

8’ x 12’ With or Without a Trailer

D

4030 VERTICALSLIDER (TY P. 5)

HVAC UNITMTD. UNDERWINDOW

SHEET VINY L FLOOR COVERING

11'-9"7

'-9

"

FLOOR PLANSCALE: 1/4" = 1'-0"

2

4F2 4F2

3068 STEEL CLAD WITHKL, GLASS LITE, WIND CHAINAND WOOD JAMB

2630 VERTICALSLIDER

PC

BUILT-IN DESK

Page 6: Guardhouses and Security Booths. Security Station Floor Plan.

“8’ x 12’ SPECIFICATIONS”STEEL SIDING: TENSILE STRENGTH / MINIMUM

YIELD STRENGTH: 55 KSI

2 x4 SYP #3 OR BETTER @ 16" O.C.

COPPER ROMEX OR NM, NMC, NMSNOTE: CONDUIT TO BE STUBBED THRU WALL /

FLOOR FROM PANEL FOR CONNECTIONBY OWNER TO EXISTING SERVICE.

ROOF:

SIDING:

APPLIED:

CEILING:

EXTERIOR TRIM:

DOORS & WINDOWS:

ELECTRICAL:

ELECTRICAL FIXTURES:

MATERIAL: COLOR: T.B.D.

{ REFER TO DOOR & WINDOW SCHEDULE}

{REFER TO ELECTRICAL PLAN}

LINING:

FOUNDATION:

FLOOR:

BLOCKING & LEVELING BY MORGAN MORGAN WILL UTILIZE TRAILER

JACKS WITH MOUNTING PLATES FORSTABILIZATION OF THE UNIT.

ANY CONCRETE SLAB, GRADE BEAMOR CONCRETE PIERS / FOOTINGSSHALL BE BY OTHERS.

EXTERIOR WALLS:

HVAC:

UNDERSHEATHING: NONE

ROAD LEGAL TRAILER WITH 4-WAY PLUG, 12 GA. GRATEPLATFORM, WITH 1" X 1" SAFETY RAILS.

2" BALL COUPLER WITH HITCH & SAFETY CHAINS ANDRUNNING LIGHTS.

MANUAL PULL OUT STEPS WITH 7" DROP/RISE, 24" WIDE.POWDER COATED BLACK TO MATCH TRAILER FRAME.

OPTIONS AVAILABLE, SUCH AS 5500 WATT GENERATOREQUIPPED, DUAL FUEL ELECTRIC START.

SINGLE JOISTS: SIDEBANDS: SINGLE

DECKING: 5/8" OR BETTER PLYWOOD or ENG.WOOD GLUED & NAILED TO JOIST

ENDBANDS: SINGLE

MATERIAL:

TPO OVER 12" O.S.B..25 VERTICAL RISE PEREVERY 12" RUN

PERMITS: TRANSPORTATION BY MORGAN ALL OTHER BY OWNER

STUDS: 2x4 SYP #3 OR BETTER @ 24" O.C. STUD & CEILING HEIGHT: REFER TO CROSS SECTION

ROOF: R-11 EXTERIOR WALLS: R-11 PARTITION WALLS: R-11 (OPTIONAL) FLOOR: R-11

1/2" VINYL GYPSUM

T.B.D.

STYLE:

ROOFING MATERIAL: PITCH:

ROOF MEMBERS:

MATERIAL:

INSULATION:

FLOOR COVERING: SHEET VINYL ROLL GOODS

VERTICAL

FLAT

PRE PAINTED STEEL

COLOR:

NOTES: DOUBLE STUDS AND HEADERS ATEXTERIOR OPENINGS OVER 48-3/4" AND INTERIORLOAD BEARING WALLS WHERE APPLICABLE.

THRU THE WALL HVAC UNITS OROPTIONAL ROOF MOUNTED UNITS.

2x4 #2 SYP @ 24" O.C.

CLASS A FINISH 1/2" PREDECKCEILING BOARD SUPPORTED BYROSETTES UNDER ROOF MEMBERS

PARTITION WALLS: STUDS: 2x4 SYP #3 OR BETTER @ 24" O.C.

NOTES: DOUBLE STUDS AND HEADERS AT INTERIOROPENINGS OVER 48-3/4" AND INTERIOR LOADBEARING WALLS WHERE APPLICABLE.

PRE PAINTED STEEL (MIN THICKNESS0.0149") OVER WATER-RESISTIVE BARRIER

TRAILER CHASSIS:

SHEATHING: AVAILABLE IN HIGH WIND AREAS.

Page 7: Guardhouses and Security Booths. Security Station Floor Plan.

8’ x 16’ with Restroom– With or Without a Trailer

2.5 GAL. INSTAN.WTR. HEATER

HVAC UNITMTD. ABOVECOUNTER TOP

SHEET VINYLFLOOR COVERING

15'-9"7'

-9"

FLOOR PLANSCALE: 1/4" = 1'-0"

3

4F2 4F2

6'-3"

4030 VERTICALSLIDER (TYP. 4)

BAR SINK INCOUNTER (NO BASE)

BUILT-IN DESK

3068 STEEL CLAD WITHKL, GLASS LITE, WIND CHAINAND WOOD JAMB

220V30A

2630 VERTICALSLIDER

PC

Page 8: Guardhouses and Security Booths. Security Station Floor Plan.

“8’ x 16’- SPECIFICATIONSSTEEL SIDING: TENSILE STRENGTH / MINIMUM

YIELD STRENGTH: 55 KSI

2 x4 SYP #3 OR BETTER @ 16" O.C.

COPPER ROMEX OR NM, NMC, NMSNOTE: CONDUIT TO BE STUBBED THRU WALL /

FLOOR FROM PANEL FOR CONNECTIONBY OWNER TO EXISTING SERVICE.

ROOF:

SIDING:

APPLIED:

CEILING:

EXTERIOR TRIM:

DOORS & WINDOWS:

ELECTRICAL:

ELECTRICAL FIXTURES:

MATERIAL: COLOR: T.B.D.

{ REFER TO DOOR & WINDOW SCHEDULE}

{REFER TO ELECTRICAL PLAN}

LINING:

FOUNDATION:

FLOOR:

BLOCKING & LEVELING BY MORGAN MORGAN WILL UTILIZE TRAILER

JACKS WITH MOUNTING PLATES FORSTABILIZATION OF THE UNIT.

ANY CONCRETE SLAB, GRADE BEAMOR CONCRETE PIERS / FOOTINGSSHALL BE BY OTHERS.

EXTERIOR WALLS:

HVAC:

PLUMBING:

UNDERSHEATHING: NONE

ROAD LEGAL TRAILER WITH 4-WAY PLUG, 12 GA. GRATEPLATFORM, WITH 1" X 1" SAFETY RAILS.

2" BALL COUPLER WITH HITCH & SAFETY CHAINS ANDRUNNING LIGHTS.

MANUAL PULL OUT STEPS WITH 7" DROP/RISE, 24" WIDE.POWDER COATED BLACK TO MATCH TRAILER FRAME.

OPTIONS AVAILABLE, SUCH AS 5500 WATT GENERATOREQUIPPED, DUAL FUEL ELECTRIC START.

SINGLE JOISTS: SIDEBANDS: SINGLE

DECKING: 5/8" OR BETTER PLYWOOD or ENG.WOOD GLUED & NAILED TO JOIST

ENDBANDS: SINGLE

MATERIAL:

TPO OVER 12" O.S.B..25 VERTICAL RISE PEREVERY 12" RUN

PERMITS: TRANSPORTATION BY MORGAN ALL OTHER BY OWNER

STUDS: 2x4 SYP #3 OR BETTER @ 24" O.C. STUD & CEILING HEIGHT: REFER TO CROSS SECTION

ROOF: R-11 EXTERIOR WALLS: R-11 PARTITION WALLS: R-11 (OPTIONAL) FLOOR: R-11

1/2" VINYL GYPSUM

T.B.D.

STYLE:

ROOFING MATERIAL: PITCH:

ROOF MEMBERS:

MATERIAL:

INSULATION:

FLOOR COVERING: SHEET VINYL ROLL GOODS

VERTICAL

FLAT

PRE PAINTED STEEL

COLOR:

NOTES: DOUBLE STUDS AND HEADERS ATEXTERIOR OPENINGS OVER 48-3/4" AND INTERIORLOAD BEARING WALLS WHERE APPLICABLE.

THRU THE WALL HVAC UNITS OROPTIONAL ROOF MOUNTED UNITS.

2x4 #2 SYP @ 24" O.C.

CLASS A FINISH 1/2" PREDECKCEILING BOARD SUPPORTED BYROSETTES UNDER ROOF MEMBERS

PARTITION WALLS: STUDS: 2x4 SYP #3 OR BETTER @ 24" O.C.

NOTES: DOUBLE STUDS AND HEADERS AT INTERIOROPENINGS OVER 48-3/4" AND INTERIOR LOADBEARING WALLS WHERE APPLICABLE.

PRE PAINTED STEEL (MIN THICKNESS0.0149") OVER WATER-RESISTIVE BARRIER

DWV LINES: PVC OR OTHER APPROVEDWATER MATERIAL LINES.

WATER SUPPLY LINES: PEX OR OTHERAPPROVED WATER MATERIAL LINES.

NOTE: PLUMBING STUBBED THROUGHFLOOR FOR CONNECTION TO ABLACK/GRAY WATER HOLDING TANK MTD.UNDERNEATH THE FLOOR JOISTS ANDBETWEEN SIDEBANDS OF THE UNIT.

THE UNITS WILL HAVE A POTABLE WATERTANK MTD. IN THE SAME CAVITY AREAUNDER THE BUILDING.

PLUMBING FIXTURES: {REFER TO PLUMBING PLAN}

TRAILER CHASSIS:

SHEATHING: AVAILABLE IN HIGH WIND AREAS.

Page 9: Guardhouses and Security Booths. Security Station Floor Plan.

8.5’ x 17’ With RestroomWith or Without a Trailer

8'-5

"

16'-9"

6'-3" 9'-214"

3'-1

0" BUILT-IN DESK2630 VERTICALSLIDER

HVAC UNITMTD. ABOVECOUNTER TOP

OPTIONALMICROWAVE ANDUNDER THE COUNTERSMALL FRIG.

4030 VERTICALSLIDER (TYP. 5)

SHEETVINYLFLOORCOVERING

PC

4F2 4F2

220V30A

3068 STEEL CLAD WITHKL, GLASS LITE, WINDCHAIN AND WOOD JAMB

Page 10: Guardhouses and Security Booths. Security Station Floor Plan.

“8’-6” X 17’- SPECIFICATIONS”STEEL SIDING: TENSILE STRENGTH / MINIMUM

YIELD STRENGTH: 55 KSI

2 x4 SYP #3 OR BETTER @ 16" O.C.

COPPER ROMEX OR NM, NMC, NMSNOTE: CONDUIT TO BE STUBBED THRU WALL /

FLOOR FROM PANEL FOR CONNECTIONBY OWNER TO EXISTING SERVICE.

ROOF:

SIDING:

APPLIED:

CEILING:

EXTERIOR TRIM:

DOORS & WINDOWS:

ELECTRICAL:

ELECTRICAL FIXTURES:

MATERIAL: COLOR: T.B.D.

{ REFER TO DOOR & WINDOW SCHEDULE}

{REFER TO ELECTRICAL PLAN}

LINING:

FOUNDATION:

FLOOR:

BLOCKING & LEVELING BY MORGAN MORGAN WILL UTILIZE TRAILER

JACKS WITH MOUNTING PLATES FORSTABILIZATION OF THE UNIT.

ANY CONCRETE SLAB, GRADE BEAMOR CONCRETE PIERS / FOOTINGSSHALL BE BY OTHERS.

EXTERIOR WALLS:

HVAC:

PLUMBING:

UNDERSHEATHING: NONE

ROAD LEGAL TRAILER WITH 4-WAY PLUG, 12 GA. GRATEPLATFORM, WITH 1" X 1" SAFETY RAILS.

2" BALL COUPLER WITH HITCH & SAFETY CHAINS ANDRUNNING LIGHTS.

MANUAL PULL OUT STEPS WITH 7" DROP/RISE, 24" WIDE.POWDER COATED BLACK TO MATCH TRAILER FRAME.

OPTIONS AVAILABLE, SUCH AS 5500 WATT GENERATOREQUIPPED, DUAL FUEL ELECTRIC START.

SINGLE JOISTS: SIDEBANDS: SINGLE

DECKING: 5/8" OR BETTER PLYWOOD or ENG.WOOD GLUED & NAILED TO JOIST

ENDBANDS: SINGLE

MATERIAL:

TPO OVER 12" O.S.B..25 VERTICAL RISE PEREVERY 12" RUN

PERMITS: TRANSPORTATION BY MORGAN ALL OTHER BY OWNER

STUDS: 2x4 SYP #3 OR BETTER @ 24" O.C. STUD & CEILING HEIGHT: REFER TO CROSS SECTION

ROOF: R-11 EXTERIOR WALLS: R-11 PARTITION WALLS: R-11 (OPTIONAL) FLOOR: R-11

1/2" VINYL GYPSUM

T.B.D.

STYLE:

ROOFING MATERIAL: PITCH:

ROOF MEMBERS:

MATERIAL:

INSULATION:

FLOOR COVERING: SHEET VINYL ROLL GOODS

VERTICAL

FLAT

PRE PAINTED STEEL

COLOR:

NOTES: DOUBLE STUDS AND HEADERS ATEXTERIOR OPENINGS OVER 48-3/4" AND INTERIORLOAD BEARING WALLS WHERE APPLICABLE.

THRU THE WALL HVAC UNITS OROPTIONAL ROOF MOUNTED UNITS.

2x4 #2 SYP @ 24" O.C.

CLASS A FINISH 1/2" PREDECKCEILING BOARD SUPPORTED BYROSETTES UNDER ROOF MEMBERS

PARTITION WALLS: STUDS: 2x4 SYP #3 OR BETTER @ 24" O.C.

NOTES: DOUBLE STUDS AND HEADERS AT INTERIOROPENINGS OVER 48-3/4" AND INTERIOR LOADBEARING WALLS WHERE APPLICABLE.

PRE PAINTED STEEL (MIN THICKNESS0.0149") OVER WATER-RESISTIVE BARRIER

DWV LINES: PVC OR OTHER APPROVEDWATER MATERIAL LINES.

WATER SUPPLY LINES: PEX OR OTHERAPPROVED WATER MATERIAL LINES.

NOTE: PLUMBING STUBBED THROUGHFLOOR FOR CONNECTION TO ABLACK/GRAY WATER HOLDING TANK MTD.UNDERNEATH THE FLOOR JOISTS ANDBETWEEN SIDEBANDS OF THE UNIT.

THE UNITS WILL HAVE A POTABLE WATERTANK MTD. IN THE SAME CAVITY AREAUNDER THE BUILDING.

PLUMBING FIXTURES: {REFER TO PLUMBING PLAN}

TRAILER CHASSIS:

SHEATHING: AVAILABLE IN HIGH WIND AREAS.

Page 11: Guardhouses and Security Booths. Security Station Floor Plan.

8’ x 13’(With or Without a Trailer)

2'-0" 3'-0"

8'-0

"

8'-0"

FLOOR PLANSCALE: 1/4" = 1'-0"

5

COUNTER

BOLLARD

BOLLARD

DUAL FLOODLIGHTS (TYP. 4)

HVACUNDERWINDOW

3030 VERTICALSLIDER (TYP. 4)

2030 VERTICALSLIDER (TYP. 3)

QUAD

QUAD

D

GENERATOR

ELEVATIONSCALE: 3/8" = 1'-0"

5A

ELEVATIONSCALE: 3/8" = 1'-0"

5B

3068 STEEL CLAD WITHKL, GLASS LITE, WINDCHAIN AND WOOD JAMB

Page 12: Guardhouses and Security Booths. Security Station Floor Plan.

“8’ X 13’ - SPECIFICATIONSSTEEL SIDING: TENSILE STRENGTH / MINIMUM

YIELD STRENGTH: 55 KSI

2 x4 SYP #3 OR BETTER @ 16" O.C.

COPPER ROMEX OR NM, NMC, NMSNOTE: CONDUIT TO BE STUBBED THRU WALL /

FLOOR FROM PANEL FOR CONNECTIONBY OWNER TO EXISTING SERVICE.

ROOF:

SIDING:

APPLIED:

CEILING:

EXTERIOR TRIM:

DOORS & WINDOWS:

ELECTRICAL:

ELECTRICAL FIXTURES:

MATERIAL: COLOR: T.B.D.

{ REFER TO DOOR & WINDOW SCHEDULE}

{REFER TO ELECTRICAL PLAN}

LINING:

FOUNDATION:

FLOOR:

BLOCKING & LEVELING BY MORGAN MORGAN WILL UTILIZE TRAILER

JACKS WITH MOUNTING PLATES FORSTABILIZATION OF THE UNIT.

ANY CONCRETE SLAB, GRADE BEAMOR CONCRETE PIERS / FOOTINGSSHALL BE BY OTHERS.

EXTERIOR WALLS:

HVAC:

UNDERSHEATHING: NONE

ROAD LEGAL TRAILER WITH 4-WAY PLUG, 12 GA. GRATEPLATFORM, WITH 1" X 1" SAFETY RAILS.

2" BALL COUPLER WITH HITCH & SAFETY CHAINS ANDRUNNING LIGHTS.

MANUAL PULL OUT STEPS WITH 7" DROP/RISE, 24" WIDE.POWDER COATED BLACK TO MATCH TRAILER FRAME.

OPTIONS AVAILABLE, SUCH AS 5500 WATT GENERATOREQUIPPED, DUAL FUEL ELECTRIC START.

SINGLE JOISTS: SIDEBANDS: SINGLE

DECKING: 5/8" OR BETTER PLYWOOD or ENG.WOOD GLUED & NAILED TO JOIST

ENDBANDS: SINGLE

MATERIAL:

TPO OVER 12" O.S.B..25 VERTICAL RISE PEREVERY 12" RUN

PERMITS: TRANSPORTATION BY MORGAN ALL OTHER BY OWNER

STUDS: 2x4 SYP #3 OR BETTER @ 24" O.C. STUD & CEILING HEIGHT: REFER TO CROSS SECTION

ROOF: R-11 EXTERIOR WALLS: R-11 PARTITION WALLS: R-11 (OPTIONAL) FLOOR: R-11

1/2" VINYL GYPSUM

T.B.D.

STYLE:

ROOFING MATERIAL: PITCH:

ROOF MEMBERS:

MATERIAL:

INSULATION:

FLOOR COVERING: SHEET VINYL ROLL GOODS

VERTICAL

FLAT

PRE PAINTED STEEL

COLOR:

NOTES: DOUBLE STUDS AND HEADERS ATEXTERIOR OPENINGS OVER 48-3/4" AND INTERIORLOAD BEARING WALLS WHERE APPLICABLE.

THRU THE WALL HVAC UNITS OROPTIONAL ROOF MOUNTED UNITS.

2x4 #2 SYP @ 24" O.C.

CLASS A FINISH 1/2" PREDECKCEILING BOARD SUPPORTED BYROSETTES UNDER ROOF MEMBERS

PARTITION WALLS: STUDS: 2x4 SYP #3 OR BETTER @ 24" O.C.

NOTES: DOUBLE STUDS AND HEADERS AT INTERIOROPENINGS OVER 48-3/4" AND INTERIOR LOADBEARING WALLS WHERE APPLICABLE.

PRE PAINTED STEEL (MIN THICKNESS0.0149") OVER WATER-RESISTIVE BARRIER

TRAILER CHASSIS:

Page 13: Guardhouses and Security Booths. Security Station Floor Plan.

8.5’ x 14’ With Restroom(With or Without a Trailer)

PC2068 INTERIOR HOLLOWCORE DOOR WITH PRIV.LOCK AND WOOD JAMB

13'-9"

8'-

5"

EXTERIOR MTD.PANEL BOX

FLOOR PLANSCALE: 1/4" = 1'-0"

6

4F2

SHEET VINYL ROLLGOODS ON FLOORTHRU OUT BLDG.

3030 VERTICALSLIDER (TYP. 6)

BUILT-IN DESK

COUNTER

2.5 GAL.INSTAN.WTR. HTR.

3068 STEEL CLAD WITHKL, GLASS LITE, WIND CHAINAND WOOD JAMB

HVAC UNITMTD. ABOVECOUNTER TOP

D

Page 14: Guardhouses and Security Booths. Security Station Floor Plan.

“8’-6” X 14’ – SPECIFICATIONS”STEEL SIDING: TENSILE STRENGTH / MINIMUM

YIELD STRENGTH: 55 KSI

2 x4 SYP #3 OR BETTER @ 16" O.C.

COPPER ROMEX OR NM, NMC, NMSNOTE: CONDUIT TO BE STUBBED THRU WALL /

FLOOR FROM PANEL FOR CONNECTIONBY OWNER TO EXISTING SERVICE.

ROOF:

SIDING:

APPLIED:

CEILING:

EXTERIOR TRIM:

DOORS & WINDOWS:

ELECTRICAL:

ELECTRICAL FIXTURES:

MATERIAL: COLOR: T.B.D.

{ REFER TO DOOR & WINDOW SCHEDULE}

{REFER TO ELECTRICAL PLAN}

LINING:

FOUNDATION:

FLOOR:

BLOCKING & LEVELING BY MORGAN MORGAN WILL UTILIZE TRAILER

JACKS WITH MOUNTING PLATES FORSTABILIZATION OF THE UNIT.

ANY CONCRETE SLAB, GRADE BEAMOR CONCRETE PIERS / FOOTINGSSHALL BE BY OTHERS.

EXTERIOR WALLS:

HVAC:

PLUMBING:

UNDERSHEATHING: NONE

ROAD LEGAL TRAILER WITH 4-WAY PLUG, 12 GA. GRATEPLATFORM, WITH 1" X 1" SAFETY RAILS.

2" BALL COUPLER WITH HITCH & SAFETY CHAINS ANDRUNNING LIGHTS.

MANUAL PULL OUT STEPS WITH 7" DROP/RISE, 24" WIDE.POWDER COATED BLACK TO MATCH TRAILER FRAME.

OPTIONS AVAILABLE, SUCH AS 5500 WATT GENERATOREQUIPPED, DUAL FUEL ELECTRIC START.

SINGLE JOISTS: SIDEBANDS: SINGLE

DECKING: 5/8" OR BETTER PLYWOOD or ENG.WOOD GLUED & NAILED TO JOIST

ENDBANDS: SINGLE

MATERIAL:

TPO OVER 12" O.S.B..25 VERTICAL RISE PEREVERY 12" RUN

PERMITS: TRANSPORTATION BY MORGAN ALL OTHER BY OWNER

STUDS: 2x4 SYP #3 OR BETTER @ 24" O.C. STUD & CEILING HEIGHT: REFER TO CROSS SECTION

ROOF: R-11 EXTERIOR WALLS: R-11 PARTITION WALLS: R-11 (OPTIONAL) FLOOR: R-11

1/2" VINYL GYPSUM

T.B.D.

STYLE:

ROOFING MATERIAL: PITCH:

ROOF MEMBERS:

MATERIAL:

INSULATION:

FLOOR COVERING: SHEET VINYL ROLL GOODS

VERTICAL

FLAT

PRE PAINTED STEEL

COLOR:

NOTES: DOUBLE STUDS AND HEADERS ATEXTERIOR OPENINGS OVER 48-3/4" AND INTERIORLOAD BEARING WALLS WHERE APPLICABLE.

THRU THE WALL HVAC UNITS OROPTIONAL ROOF MOUNTED UNITS.

2x4 #2 SYP @ 24" O.C.

CLASS A FINISH 1/2" PREDECKCEILING BOARD SUPPORTED BYROSETTES UNDER ROOF MEMBERS

PARTITION WALLS: STUDS: 2x4 SYP #3 OR BETTER @ 24" O.C.

NOTES: DOUBLE STUDS AND HEADERS AT INTERIOROPENINGS OVER 48-3/4" AND INTERIOR LOADBEARING WALLS WHERE APPLICABLE.

PRE PAINTED STEEL (MIN THICKNESS0.0149") OVER WATER-RESISTIVE BARRIER

DWV LINES: PVC OR OTHER APPROVEDWATER MATERIAL LINES.

WATER SUPPLY LINES: PEX OR OTHERAPPROVED WATER MATERIAL LINES.

NOTE: PLUMBING STUBBED THROUGHFLOOR FOR CONNECTION TO ABLACK/GRAY WATER HOLDING TANK MTD.UNDERNEATH THE FLOOR JOISTS ANDBETWEEN SIDEBANDS OF THE UNIT.

THE UNITS WILL HAVE A POTABLE WATERTANK MTD. IN THE SAME CAVITY AREAUNDER THE BUILDING.

PLUMBING FIXTURES: {REFER TO PLUMBING PLAN}

TRAILER CHASSIS:

SHEATHING: AVAILABLE IN HIGH WIND AREAS.

Page 15: Guardhouses and Security Booths. Security Station Floor Plan.

6’ x 14’ With Restroom (With or Without a Trailer)

PC

2068 INTERIOR HOLLOWCORE DOOR WITH PRIV.LOCK AND WOOD JAMB

13'-9"

6'-0

"

FLOOR PLANSCALE: 1/4" = 1'-0"

7

4F2

SHEET VINYL ROLLGOODS ON FLOORTHRU OUT BLDG.

3030 VERTICALSLIDER (TYP. 4)

BUILT-INDESK

8'-812"

ROOFMTD. HVACUNIT

4'-0"

3068 STEEL CLAD WITHKL, GLASS LITE, WINDCHAIN AND WOOD JAMB

Page 16: Guardhouses and Security Booths. Security Station Floor Plan.

“6’ X 14’ - SPECIFICATIONSSTEEL SIDING: TENSILE STRENGTH / MINIMUM

YIELD STRENGTH: 55 KSI

2 x4 SYP #3 OR BETTER @ 16" O.C.

COPPER ROMEX OR NM, NMC, NMSNOTE: CONDUIT TO BE STUBBED THRU WALL /

FLOOR FROM PANEL FOR CONNECTIONBY OWNER TO EXISTING SERVICE.

ROOF:

SIDING:

APPLIED:

CEILING:

EXTERIOR TRIM:

DOORS & WINDOWS:

ELECTRICAL:

ELECTRICAL FIXTURES:

MATERIAL: COLOR: T.B.D.

{ REFER TO DOOR & WINDOW SCHEDULE}

{REFER TO ELECTRICAL PLAN}

LINING:

FOUNDATION:

FLOOR:

BLOCKING & LEVELING BY MORGAN MORGAN WILL UTILIZE TRAILER

JACKS WITH MOUNTING PLATES FORSTABILIZATION OF THE UNIT.

ANY CONCRETE SLAB, GRADE BEAMOR CONCRETE PIERS / FOOTINGSSHALL BE BY OTHERS.

EXTERIOR WALLS:

HVAC:

PLUMBING:

UNDERSHEATHING: NONE

ROAD LEGAL TRAILER WITH 4-WAY PLUG, 12 GA. GRATEPLATFORM, WITH 1" X 1" SAFETY RAILS.

2" BALL COUPLER WITH HITCH & SAFETY CHAINS ANDRUNNING LIGHTS.

MANUAL PULL OUT STEPS WITH 7" DROP/RISE, 24" WIDE.POWDER COATED BLACK TO MATCH TRAILER FRAME.

OPTIONS AVAILABLE, SUCH AS 5500 WATT GENERATOREQUIPPED, DUAL FUEL ELECTRIC START.

SINGLE JOISTS: SIDEBANDS: SINGLE

DECKING: 5/8" OR BETTER PLYWOOD or ENG.WOOD GLUED & NAILED TO JOIST

ENDBANDS: SINGLE

MATERIAL:

TPO OVER 12" O.S.B..25 VERTICAL RISE PEREVERY 12" RUN

PERMITS: TRANSPORTATION BY MORGAN ALL OTHER BY OWNER

STUDS: 2x4 SYP #3 OR BETTER @ 24" O.C. STUD & CEILING HEIGHT: REFER TO CROSS SECTION

ROOF: R-11 EXTERIOR WALLS: R-11 PARTITION WALLS: R-11 (OPTIONAL) FLOOR: R-11

1/2" VINYL GYPSUM

T.B.D.

STYLE:

ROOFING MATERIAL: PITCH:

ROOF MEMBERS:

MATERIAL:

INSULATION:

FLOOR COVERING: SHEET VINYL ROLL GOODS

VERTICAL

FLAT

PRE PAINTED STEEL

COLOR:

NOTES: DOUBLE STUDS AND HEADERS ATEXTERIOR OPENINGS OVER 48-3/4" AND INTERIORLOAD BEARING WALLS WHERE APPLICABLE.

THRU THE WALL HVAC UNITS OROPTIONAL ROOF MOUNTED UNITS.

2x4 #2 SYP @ 24" O.C.

CLASS A FINISH 1/2" PREDECKCEILING BOARD SUPPORTED BYROSETTES UNDER ROOF MEMBERS

PARTITION WALLS: STUDS: 2x4 SYP #3 OR BETTER @ 24" O.C.

NOTES: DOUBLE STUDS AND HEADERS AT INTERIOROPENINGS OVER 48-3/4" AND INTERIOR LOADBEARING WALLS WHERE APPLICABLE.

PRE PAINTED STEEL (MIN THICKNESS0.0149") OVER WATER-RESISTIVE BARRIER

DWV LINES: PVC OR OTHER APPROVEDWATER MATERIAL LINES.

WATER SUPPLY LINES: PEX OR OTHERAPPROVED WATER MATERIAL LINES.

NOTE: PLUMBING STUBBED THROUGHFLOOR FOR CONNECTION TO ABLACK/GRAY WATER HOLDING TANK MTD.UNDERNEATH THE FLOOR JOISTS ANDBETWEEN SIDEBANDS OF THE UNIT.

THE UNITS WILL HAVE A POTABLE WATERTANK MTD. IN THE SAME CAVITY AREAUNDER THE BUILDING.

PLUMBING FIXTURES: {REFER TO PLUMBING PLAN}

TRAILER CHASSIS:

SHEATHING: AVAILABLE IN HIGH WIND AREAS.

Page 17: Guardhouses and Security Booths. Security Station Floor Plan.

Security Station Floor Security Station Floor PlanPlan

Page 18: Guardhouses and Security Booths. Security Station Floor Plan.

Security StationSecurity Station

Page 19: Guardhouses and Security Booths. Security Station Floor Plan.
Page 20: Guardhouses and Security Booths. Security Station Floor Plan.

“Trailer Mounted Option”Trailer HighlightsRadial tires: 6 lug hub, ST225/75/R15 LRDGross vehicle weight rating (GVW) of 10,000 lbs (18-20' trailer) or 15,000 lbs (24' trailer)All axles have brakesBuilding FootprintActual Trailer Width: 8'6"Trailer Bed Width: 6'11"5/8"DIA. Zinc plated all-threaded rods, on corners (8)Minimum tongue length of 4'Trailer ElementsExterior Structure: HSS 5x2x.120Interior Structure: C3"x3.5 per linear footThreaded Rod Yield Strength: 45ksi, handles load of 8,900 lbsDexter Spring 5,200 lb axleFlashing: 22 gauge galvanized steel sheetTowing Specs7 Blade Trailer Connector for electrical wiringStandard 2 - 5/16” ball hitchSafety chains: rated for 7,600 lbs. eachOther ItemsHitch Jack: rated to hold 2,000 lbsScissor Leveling Jacks (4)The trailer finish is a 2 part process with an epoxy primer and a urethane top coatBracket-mounted trailer lights for easy removal during building & reapplication after construction, with incandescent bulbs (8)

Page 21: Guardhouses and Security Booths. Security Station Floor Plan.

“Options Available”All Models

Winco HPS6000HE - 5500 Watt Dual Fuel Generator with Electric Start Honda Engine. Bi-Fuel Carburetor and Gas Regulator

• Versatile generator runs on natural gas or gasoline• 11-HP Electric Start Honda Engine• Premium-quality, fuel-efficient engine with low oil protection• Standard electric start w/ battery rack and cables• Battery not included; Group 20 or 24HL 300CCA(Not Included)• Dual element air filter reduces maintenance• Brushless Alternator• Inherent voltage regulation protects electronics from surges• Less than 6% THD (Total Harmonic Distortion)• 100% copper windings, NEMA Class F insulation• NOTICE: BI-FUEL STARTING• Bi-Fuel generators operating on vapor fuel ( NG)• Must be started using the electric start system provided.• You cannot hand crank the unit fast enough to develop the proper• Vacuum to make the vapor fuel system work.• WHEN USING VAPOR FUEL NEVER USE THE CHOKE• Use of the choke will prevent air and fuel from properly mixing.• Recommended Battery - Group 20 or 24HL 300CCA(Not Included)

Page 22: Guardhouses and Security Booths. Security Station Floor Plan.

24 hour Emergency number 214-697-3543

12700 Hillcrest Rd.Dallas ,TX. 752301-972-864-7341

FAX 1-972-864-7313

A Founding Member of the Modular Building Institute

morganbuildingsystems.com