filtratio echnologies FTP SERIES CARTRIDGE FILTERS …PRFV)(eng).pdf · filtration technologies 7...

8
® filtration technologies FTP SERI ES CARTRI DGE F I LTERS (GRP F I LTER HOUSI NG) The permanent filtering solution

Transcript of filtratio echnologies FTP SERIES CARTRIDGE FILTERS …PRFV)(eng).pdf · filtration technologies 7...

Page 1: filtratio echnologies FTP SERIES CARTRIDGE FILTERS …PRFV)(eng).pdf · filtration technologies 7 Project Country Capacity m3/day Shuqaiq II IWPP Saudi Arabia 240,000 ETAP Abrera

®

filtration technologies

FTP SERIES CARTRIDGEFILTERS(GRP FILTERHOUSING)

The permanentfiltering solution

Page 2: filtratio echnologies FTP SERIES CARTRIDGE FILTERS …PRFV)(eng).pdf · filtration technologies 7 Project Country Capacity m3/day Shuqaiq II IWPP Saudi Arabia 240,000 ETAP Abrera

2 filtration technologies

ftp series cartridge filters (grp)

■ Perfect corrosion resistance behaviour.■ Reduced maintenance during its life span.■ Excellent quality/price ratio, above all in

filters for treating large flows.■ High resistance when treating waters

with a high degree of salinity.■ Versatility in design for different pressures.

Advantages

Standard materials

IntroductionFluytec GRP (Glass Fibre Reinforced Polyester) cartridge filters provide optimal behaviour with water of various degrees of salinity, reducing the maintenance needed in these conditions and optimizing the installation cost of filtering equipment.

General review of Double Flange Filter.

The bodies of these filters are designed according to the Ad-Merkblatt design code from pressure vessels and are made according to the 97/23 CE S. S.3.3 European Standard for Pressure Filters.

The standard pressure is 6 bar and it is possible to design equipment for different nominal pressures to order.

The internal parts in contact with the water are of various plastics and, when of metal, are suitably plasticised. The seals are O-rings and are designed for easy replacement and maintenance.

The bodies have a natural internal finish while externally they are covered with a twin component paint and finished with a top coat of paint.

All the main connections for the fluid inlet and outlet and the vent and drain are designed with flanges.

The equipment is anchored at the base with Carbon Steel legs, each with a hole for anchoring studs, not supplied by the manufacturer.

General description

View of top opening of Double Flange Filter.

Body: GRP

FF plate: GRP / PVC

Legs: Coated CS *

External bolts: AISI 304*

Internal parts: PVC

O-ring: EPDM*

*Other materials available.

Page 3: filtratio echnologies FTP SERIES CARTRIDGE FILTERS …PRFV)(eng).pdf · filtration technologies 7 Project Country Capacity m3/day Shuqaiq II IWPP Saudi Arabia 240,000 ETAP Abrera

3filtration technologies

ftp series cartridge filters (grp)

Page 4: filtratio echnologies FTP SERIES CARTRIDGE FILTERS …PRFV)(eng).pdf · filtration technologies 7 Project Country Capacity m3/day Shuqaiq II IWPP Saudi Arabia 240,000 ETAP Abrera

4 filtration technologies

ftp series cartridge filters (grp)

Traditional double flange type cartridge filters with 40 to 100 cartridges.

These filters have inlet and outlet connections on the side of the body consisting of two flanges, an upper one, also called the closure, and a low one at the bottom, on which the cartridges are housed.

1. FTP Medium Flow series

Cartridge installation

■ Possibility of equipping with a lifting arm.

Options

The bottom of the cartridge is located on the guide pipe, the base of which has a perimeter flange to seal the bottom end of the cartridge - Figure 1 -. The top is closed with a part exclusively designed and manufactured by Fluytec called “teat” which is pressed against the

cartridge by the spring between it and the top and/or filter lid - Figures 2 and 3 -.

This system ensures the perfect sealing of the cartridge, making it impossible for the fluid to pass through any place other than the filtering medium (the end purpose of the filter) - Figure 4 -.

Model ADN B C H L N1/N2

DNQdesignm3/hour

No. cartridges

L cartridges

80 FTP-4 FL 750 485 1,365 2,140 595 200 208 80 1,000

80 FTP-5 FL 750 485 1,490 2,390 595 200 260 80 1,250

90 FTP-4 FL 800 500 1,405 2,175 625 200 234 90 1,000

90 FTP-5 FL 800 500 1,530 2,425 675 250 292 90 1,250

• Measurements in mm.

• Measurements for a design pressure of 6 bar. Other measurements/flows to order.

• Design flows calculated for a flow rate of 0.65 m³/h for every 10” of cartridge.

Virgen del Milagro desalination plant, Mazarrón (Murcia).

2

4

1

3

AL

H

B

C

Page 5: filtratio echnologies FTP SERIES CARTRIDGE FILTERS …PRFV)(eng).pdf · filtration technologies 7 Project Country Capacity m3/day Shuqaiq II IWPP Saudi Arabia 240,000 ETAP Abrera

5filtration technologies

ftp series cartridge filters (grp)

Traditional double flange type cartridge filters with 120 to 400 cartridges.

These filters have inlet and outlet connections on the side of the body consisting of two flanges, an upper one, also called the closure, and a low one at the bottom, on which the cartridges are housed.

2. FTP HighFlow series: double flange

■ Possibility of equipping with a lifting arm.■ Possibility of equipping with inlet and

outlet elbows.

Options

Cartridge installationThe bottom of the cartridge is located on the guide pipe, the base of which has a perimeter flange to seal the bottom end of the cartridge - Figure 1 -. The top is closed with a part exclusively designed and manufactured by Fluytec called “teat” which is pressed against the

cartridge by the spring between it and the top and/or filter lid - Figures 2 and 3 -.

This system ensures the perfect sealing of the cartridge, making it impossible for the fluid to pass through any place other than the filtering medium (the end purpose of the filter) - Figure 4 -.

2

4

1

3

Installation in Abrera, Barcelona.

Model ADN B C H L N1/N2

DNQdesignm3/hour

No. cartridges

L cartridges

100 FTP-4 FL 850 750 1,850 2,650 690 250 260 100 1,000

100 FTP-5 FL 850 750 1,975 2,900 690 250 325 100 1,000

120 FTP-4 FL 925 750 1,870 2,680 670 250 312 120 1,000

120 FTP-5 FL 925 750 1,995 2,930 670 250 390 120 1,250

135 FTP-4 FL 950 750 1,880 2,700 750 250 351 135 1,000

135 FTP-5 FL 950 750 2,005 2,950 750 250 438 135 1,250

150 FTP-4 FL 1,000 750 1,910 2,760 780 250 390 150 1,000

150 FTP-5 FL 1,000 750 2,035 3,010 780 250 487 150 1,250

180 FTP-4 FL 1,100 750 1,945 2,820 820 250 468 180 1,000

180 FTP-5 FL 1,100 875 2,235 3,230 820 300 585 180 1,250

215 FTP-4 FL 1,200 875 2,135 3,030 920 300 559 215 1,000

215 FTP-5 FL 1,200 950 2,335 3,350 920 350 698 215 1,250

240 FTP-4 FL 1,300 950 2,215 3,130 970 350 624 240 1,000

240 FTP-5 FL 1,300 950 2,340 3,380 970 350 780 240 1,250

280 FTP-4 FL 1,400 950 2,245 3,185 1,020 350 728 280 1,000

280 FTP-5 FL 1,400 1,050 2,470 3,535 1,020 400 910 280 1,250

330 FTP-4 FL 1,500 1,050 2,375 3,345 1,075 400 858 330 1,000

330 FTP-5 FL 1,500 1,050 2,500 3,595 1,075 400 1,072 330 1,250

360 FTP-4 FL 1,600 1,050 2,405 3,400 1,125 400 936 360 1,000

360 FTP-5 FL 1,600 1,050 2,530 3,650 1,125 400 1,170 360 1,250

• Measurements in mm.

• Measurements for a design pressure of 6 bar. Other measurements/flows to order.

• Design flows calculated for a flow rate of 0.65 m³/h for every 10” of cartridge.

AL

H

B

C

Page 6: filtratio echnologies FTP SERIES CARTRIDGE FILTERS …PRFV)(eng).pdf · filtration technologies 7 Project Country Capacity m3/day Shuqaiq II IWPP Saudi Arabia 240,000 ETAP Abrera

6 filtration technologies

ftp series cartridge filters (grp)

Cartridge filters with sword system and single flange for high flows.

Filters consisting of a body with a single flange in which the inlet connection is at the bottom while the outlet is in the top lid of the filter.

The false bottom plate on the flange is the support from which the swords hang.

3. FTP HighFlow series:swords system

The filter cartridges are mounted on swords, supports with their heads screwed into the false bottom plate and with a nut threaded onto their tops to seal the cartridge - Figure 1 -.

The lower plastic grille gives the filter pack the necessary rigidity to prevent the

cartridges from breaking due to internal vibration - Figure 2 -. With an additional false bottom plate and set of swords, a filter pack can be prepared on site while the other is operating, thus reducing the equipment’s downtime - Figure 3 - .

Cartridge installation

Installation in Águilas, Murcia.

■ Replacement of complete filter pack.■ Optimizing of filtering cross section.■ Economical manufacture.■ Possibility of equipping with inlet and

outlet elbows.

Advantages

21

3

Replacement of filter pack.

Model ADN

B H N1/N2DN

Qdesignm3/hour

No.cartridges

L cartridges

120 FTP-4 B 900 750 3,040 250 312 120 1,000

120 FTP-5 B 900 750 3,285 250 390 120 1,250

120 FTP-7 B 900 875 3,960 300 546 120 1,750

150 FTP-4 B 1,000 750 3,095 250 390 150 1,000

150 FTP-5 B 1,000 750 3,345 250 487 150 1,250

150 FTP-7 B 1,000 875 4,020 300 682 150 1,750

180 FTP-4 B 1,100 750 3,140 250 468 180 1,000

180 FTP-5 B 1,100 875 3,615 300 585 180 1,250

180 FTP-7 B 1,100 950 4,140 350 819 180 1,750

240 FTP-4 B 1,200 875 3,410 300 624 240 1,000

240 FTP-5 B 1,200 950 3,735 350 780 240 1,250

240 FTP-7 B 1,200 1,050 4,285 400 1,092 240 1,750

270 FTP-4 B 1,300 875 3,435 300 702 270 1,000

270 FTP-5 B 1,300 950 3,760 350 877 270 1,250

270 FTP-7 B 1,300 1,050 4,310 400 1,228 270 1,750

310 FTP-4 B 1,400 950 3,565 350 806 310 1,000

310 FTP-5 B 1,400 1,050 3,910 400 1,007 310 1,250

310 FTP-7 B 1,400 1,150 4,465 450 1,410 310 1,750

360 FTP-4 B 1,500 950 3,615 350 936 360 1,000

360 FTP-5 B 1,500 1,050 3,965 400 1,170 360 1,250

360 FTP-7 B 1,500 1,300 4,665 500 1,638 360 1,750

400 FTP-4 B 1,600 1,050 3,765 400 1,040 400 1,000

400 FTP-5 B 1,600 1,150 4,115 450 1,300 400 1,250

400 FTP-7 B 1,600 1,300 4,715 500 1,820 400 1,750

• Measurements in mm.

• Measurements for design pressure of 6 bar; other measurements/flows to order.

A

H

B

Page 7: filtratio echnologies FTP SERIES CARTRIDGE FILTERS …PRFV)(eng).pdf · filtration technologies 7 Project Country Capacity m3/day Shuqaiq II IWPP Saudi Arabia 240,000 ETAP Abrera

7filtration technologies

Project Country Capacity m3/day

Shuqaiq II IWPP Saudi Arabia 240,000

ETAP Abrera Spain 220,000

Rabigh IWPP Saudi Arabia 220,000

Al Dur Bahrain 214,000

UDEM Ténès Algeria 200,000

Águilas Guadalentín Spain 200,000

Hamma SWRO Algeria 200,000

Sant Joan Despí Spain 190,000

Perth II SWRO, phase 1 Australia 153,000

Barka II SWRO Oman 153,000

Perth II SWRO, phase 2 Australia 153,000

Trinidad and Tobago SWRO Trinidad and Tobago 130,000

Bahía de Palma SWRO Spain 68,000

WTP for Steel Plant Turkey 65,000

Aruba SWRO Netherlands Antilles 57,120

Tía Juana Venezuela 48,000

Harley SWRO USA 40,000

Ouargla BWRO Algeria 40,000

Sta. Bárbara IDAM Curaçao 25,000

Marsa Matrouth SWRO Egypt 24,000

Copiapó SWRO Chile 18,000

Mossel Bay SWRO South Africa 15,000

ftp series cartridge filters (grp)

Fluytec filters process 12,000,000 m3 per day in installations worldwide, making it the leader in the national market and with an increasing international presence.

The following table shows some references for Fluytec projects, reflecting its worldwide presence.

Fluytec references

Fluytec installations in various parts of the world.

Page 8: filtratio echnologies FTP SERIES CARTRIDGE FILTERS …PRFV)(eng).pdf · filtration technologies 7 Project Country Capacity m3/day Shuqaiq II IWPP Saudi Arabia 240,000 ETAP Abrera

Camino de Sakoni, 18 • 48950 Erandio - Vizcaya (Spain) • T: (+34) 94 467 61 50 • F: (+34) 94 467 61 [email protected] • www.fluytec.com

Sub

ject

to c

hang

e w

ithou

t not

ice.

See our Website for other design criteria

Fluytec solutions worldwide

■ FTI series cartridge filters (SS, CS)■ FTPV series cartridge filters (PVC)■ …

Other products in this range:

v.4