ETT-15 DATA SHEET - N00325 Temperature Transducer Pt100, Cu10 and Resistance Page 1/4 August 2008 Characteristics Electronic transducer for mounting in panels or machines. This transducer is properly designed for conversion of voltage or ohmic resistance into a direct voltage or current signal. It can be used also for temperature measuring by means of two-wire or three wire thermocouples and thermo resistances. The input signal is converted in a proportional, aligned or not aligned output signal, which is independent of the load. Galvanic isolation between input and output signals. Sensor break protection device. The output signal is compatible for connection of various instruments, such as: analogical or digital indicators, graph records, controllers, analogical digital converters and others. Application Industrial ovens Engines Heat treatment Transformers TAP position Technical data (NBR 8145) Input Ohmic resistance Two-wire or three-wire thermo resistance Teletransmitter with potentiometer Current sensor Pt100: 1mA. Cu: 5mA. Resistance; according field Auxiliary power supply (Uax) Universal. 85 … 265Vac / 90 … 300Vdc consumption ~ 4VA. 20…60Vac/Vdc consumption ~ 4VA. Output: 0 … 1mA RC 10 kΩ 0 … 5mA RC 2 kΩ 0 … 10mA RC 1kΩ 0 … 20mA RC 500 Ω 4… 20mA RC 500 Ω 0 … 10V RC 500 Ω 1 … 5V RC 500 Ω Sensor break protection device: When the sensor break, the output will be saturated in end of scale (standard version). Optional: Saturation in the beginning of scale. Influence magnitudes Error limit 0,5% (standard), 0,25% (optional) Reference conditions Input: 0…100% Auxiliary power supply: Uax ± 2% Ambient temperature: 25°C ±2K Heat time: ± 20 min. Linearity deviation 0,2% (included in error limit) Temperature 0,2%/10 K; rated temperature 25°C (Optional 0,1%/10K for Pt100) Auxiliary power supply 0,05% within the permitted tolerance range for the supply voltage External magnetic fields Radio frequency interference 0,5% for field intensity of 0,4 kA/m 0,5% between 27…460MHz at a distance of 1 m power 1 W Electrical test Voltage test Uax. 85V : 2,5kV/1 min ; 60Hz (for all circuits mutually). Uax. 60V: 1,5kV/1 min ; 60Hz (for all circuits mutually).

description

WERE

Transcript of ETT15EN

Page 1: ETT15EN

ETT-15 DATA SHEET - N00325

Temperature Transducer Pt100, Cu10 and Resistance

Page 1/4 August 2008

Characteristics Electronic transducer for mounting in panels or machines. This transducer is properly designed for conversion of voltage or ohmic resistance into a direct voltage or current signal. It can be used also for temperature measuring by means of two-wire or three wire thermocouples and thermo resistances. The input signal is converted in a proportional, aligned or not aligned output signal, which is independent of the load. Galvanic isolation between input and output signals. Sensor break protection device. The output signal is compatible for connection of various instruments, such as: analogical or digital indicators, graph records, controllers, analogical digital converters and others. Application Industrial ovens Engines Heat treatment Transformers TAP position Technical data (NBR 8145) Input

Ohmic resistance Two-wire or three-wire thermo resistance Teletransmitter with potentiometer Current sensor Pt100: ≤ 1mA.

Cu: ≤ 5mA. Resistance; according field

Auxiliary power supply (Uax)

Universal. 85 … 265Vac / 90 … 300Vdc consumption ~ 4VA. 20…60Vac/Vdc consumption ~ 4VA.

Output: 0 … 1mA RC ≤ 10 kΩ

0 … 5mA RC ≤ 2 kΩ 0 … 10mA RC ≤ 1kΩ 0 … 20mA RC ≤ 500 Ω 4… 20mA RC ≤ 500 Ω 0 … 10V RC ≥500 Ω 1 … 5V RC ≥ 500 Ω

Sensor break protection device: When the sensor break, the output will be saturated in end of scale (standard version). Optional: Saturation in the beginning of scale. Influence magnitudes Error limit 0,5% (standard),

0,25% (optional) Reference conditions

Input: 0…100%

Auxiliary power

supply: Uax ± 2%

Ambient temperature: 25°C ±2K Heat time: ± 20 min. Linearity deviation ≤ 0,2%

(included in error limit) Temperature ≤ 0,2%/10 K;

rated temperature 25°C (Optional 0,1%/10K for Pt100)

Auxiliary power supply ≤ 0,05% within the permitted tolerance range for the supply voltage

External magnetic fields Radio frequency interference

≤ 0,5% for field intensity of 0,4 kA/m ≤ 0,5% between 27…460MHz at a distance of 1 m power 1 W

Electrical test Voltage test Uax. ≥ 85V : 2,5kV/1 min ; 60Hz

(for all circuits mutually). Uax. ≤ 60V: 1,5kV/1 min ; 60Hz (for all circuits mutually).

Page 2: ETT15EN

ETT-15 DATA SHEET - N00325

Temperature Transducer Pt100, Cu10 and Resistance

Page 2/4 August 2008

Construction and mounting Housing Base and cover of plastic. Fastening Surface mounting with two screws M4, or

using DIN rail Electrical connection

Frontal terminals for eye and fork type cable shoes.

Protection class (NBR 6146)

IP 50 in housing IP 20 at the connection terminals

Weight 0,3 kg Climatic conditions Operation temperature -20...+60°C Functioning temperature -25...+70°C Transport and storage temp. -40...+80°C Relative humidity 75% of annual average with

light condensation. (others on consult)

Mechanical test Impact Acceleration 30g, during 11ms Vibration Acceleration 2g, frequency 5..150Hz Dimensional Drawing Dimension in mm

Input Signal The sensor input signal is done by 51,52,53 and 54 born. Connection two-wire – Wire resistance. Terminals 51,52 – Place a compensation resistance with ohmic value equal to the line resistance value. Terminals 53,54 – sensor.

Connection three-wire Terminals 51,53 – sensor common point, Terminal 54 – other common point. Obs.: The 3 wires should have the same line resistance.

Output Signal Auxiliary power supply Terminals 61 (+) e 62 (-) Terminals 13 e 14.

Page 3: ETT15EN

ETT-15 DATA SHEET - N00325

Temperature Transducer Pt100, Cu10 and Resistance

Page 3/4 August 2008

Additional Information The following items contain tips and cautions to be observed by the user for a good functional performance, as well as the maintenance of the instrument and the safety of the installation.

Example for measuring the transformer temperature:

Cautions Be sure the voltages and currents to be connected to the instrument are compatible. Loosen all connections from the instrument before removing it from the installation. Mounting Instructions Observe the environment temperature range. At the place of installation, values for vibration, dust, dirt and humidity, which must remain between the limits, established by the protection class of the housing and the climatic group, specified in this data sheet, have to be observed. For fastening on flat area use two M4 screws. For mounting on DIN rail, use the snap-in device on the rear of the instrument. The connections can be made with eye or fork type cable shoes Instructions for Use When connections have been made, switch on the power supply and check at the output the functioning of the transducer.

Temperature Sensor

- Indicators - Graph Records - Controllers - PLCs - Remotes

ETT-15

Transformer

Page 4: ETT15EN

ETT-15 DATA SHEET - N00325

Temperature Transducer Pt100, Cu10 and Resistance

Page 4/4 August 2008

Ordering information Catalog number

TRANSDUCER ETT-15 Case N 0 0 3 2 5

Input Signal Thermoresistance Pt100 (temperature range to be informed) between –200…+850ºC. 01 Measuring Resistance 10 ohm…10Kohm 02 Thermoresistance Cu10 (0-150ºC, or 0-180ºC or 0-200ºC) 03

Auxiliary power supply 20…60 Vca/cc 12 85…265Vac e 90…300Vdc 13

Output Signal 0…1mAcc 1 0…5mAcc 2 0…10mAcc 3 0…20mAcc 4 4…20mAcc 5 0…10Vcc 7 Others (0…1mAcc up to 20mAcc and 0…1Vcc up to 0…15Vcc)

0

Option Class 0,25% ( only for Pt100 and resistance) 1 Normal (Error limit 0,5%) 5

Additional Information Complement (Inform temperature range) C

Normal 1

Example: Transducer ETT15 Case Input signal: Thermoresistance Pt100 0-100ºC Auxiliary power supply: 85…265Vca e 90…300Vcc Output Signal: 4…20mAcc Option: Class 0,25% Additional Information: Normal Code number: N003250113511