Eplan Electric p8 Basic 2

download Eplan Electric p8 Basic 2

of 211

Transcript of Eplan Electric p8 Basic 2

  • 5/26/2018 Eplan Electric p8 Basic 2

    1/211

    EPLAN electric P8 training by Sysnet Controls Sdn. Bhd.http://www.eplan.com.my/

    Version 1.7.12

    Basic Training

    Date : 10thSeptember 2007 14thSeptember 2007Venue : Sysnet Controls Sdn Bhd Training Room

  • 5/26/2018 Eplan Electric p8 Basic 2

    2/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 1/213

    Day 1 ..........................................Error! Bookmark not defined.Installation ..................................Error! Bookmark not defined.Project ........................................Error! Bookmark not defined.

    Opening a project .................................Error! Bookmark not defined.Project management ............................Error! Bookmark not defined.

    User interface ............................Error! Bookmark not defined.Creating / Configuring a workspace .....Error! Bookmark not defined.Saving a new workspace ...................... Error! Bookmark not defined.Changing the key assignment for a command ....Error! Bookmark notdefined.Creating an own icon and linking it to an action ..Error! Bookmark notdefined.Transferring user-specific settings to a different computer in thenetwork .................................................Error! Bookmark not defined.Inserting a symbol ................................ Error! Bookmark not defined.Exercise ................................................ Error! Bookmark not defined.Symbol selection navigator ..................Error! Bookmark not defined.Pair cross-reference or contact image at motor overload switch ..Error!Bookmark not defined.Notes Pad ............................................. Error! Bookmark not defined.

    Day 2 ..........................................Error! Bookmark not defined.New project ................................Error! Bookmark not defined.Changing the project structure ..Error! Bookmark not defined.GED ...........................................Error! Bookmark not defined.

    Hyperlink/image ....................................Error! Bookmark not defined.External documents ..............................Error! Bookmark not defined.Texts .....................................................Error! Bookmark not defined.Drawing a graphic ................................ Error! Bookmark not defined.Layer management ..............................Error! Bookmark not defined.

    Part / Device selection ...............Error! Bookmark not defined.Part selection ........................................Error! Bookmark not defined.

    Device selection ...................................Error! Bookmark not defined.

    Part management ......................Error! Bookmark not defined.Inserting a device .................................Error! Bookmark not defined.Generating a type .................................Error! Bookmark not defined.Writing back cable conductor data .......Error! Bookmark not defined.Synchronizing the parts database ........Error! Bookmark not defined.

  • 5/26/2018 Eplan Electric p8 Basic 2

    3/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 2/213

    Device list .............................................Error! Bookmark not defined.Setting a user-defined part selection (project-specific) .................Error!Bookmark not defined.Management Parts selection ................Error! Bookmark not defined.

    Management Parts management ......... Error! Bookmark not defined.Notes Pad ............................................. Error! Bookmark not defined.

    New function in Terminals navigator ........Error! Bookmark notdefined.Unplaced functions ....................Error! Bookmark not defined.Interconnecting devices .............Error! Bookmark not defined.Connected functions ..................Error! Bookmark not defined.Function types ...........................Error! Bookmark not defined.

    Moving a main function and synchronizing data..Error! Bookmark not

    defined.Macro techniques ......................Error! Bookmark not defined.

    Window macro ......................................Error! Bookmark not defined.Symbol macro ...................................... Error! Bookmark not defined.Page macro ..........................................Error! Bookmark not defined.Drag-and-drop ......................................Error! Bookmark not defined.Macro project / Macro variants .............Error! Bookmark not defined.Modifying a macro variant in the schematic ........Error! Bookmark notdefined.

    Updating the macro ..............................Error! Bookmark not defined.Placeholder texts ..................................Error! Bookmark not defined.Notes Pad ............................................. Error! Bookmark not defined.

    Day 4 ..........................................Error! Bookmark not defined.Numbering .................................Error! Bookmark not defined.

    Cable numbering with source / target ...Error! Bookmark not defined.Plugs ....................................................Error! Bookmark not defined.DT numbering .......................................Error! Bookmark not defined.

    Interruption points ......................Error! Bookmark not defined.

    Interruption point navigator ...................Error! Bookmark not defined.Modifying the interruption point symbol Error! Bookmark not defined.

    Diagonal "Exercise project TYP01" ..........Error! Bookmark notdefined.Bundle ........................................Error! Bookmark not defined.Potential / signal ........................Error! Bookmark not defined.Connection numbering ..............Error! Bookmark not defined.

  • 5/26/2018 Eplan Electric p8 Basic 2

    4/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 3/213

    Numbering only for a specific potential or signal .Error! Bookmark notdefined.How can I number only the connections for a group of DTs (forexample -F)? ........................................Error! Bookmark not defined.

    Contact image ............................Error! Bookmark not defined.Setting up personal properties ...Error! Bookmark not defined.Changing the zoom, pan and scroll functions of the mouse...................................................Error! Bookmark not defined.

    Notes Pad ............................................. Error! Bookmark not defined.

    Day 5..........................................Error! Bookmark not defined.Tips and tricks ............................Error! Bookmark not defined.

    Finding the next free counter ................Error! Bookmark not defined.Placing a DT without the Properties dialog box opening ..............Error!

    Bookmark not defined.Predefinition of the identifiers ...............Error! Bookmark not defined.Part selection with filter to identifier ......Error! Bookmark not defined.Sorting the terminals as drawn in the schematic (EPLAN 5 sortingsetting: ..................................................Error! Bookmark not defined.Terminal on left) ...................................Error! Bookmark not defined.Displaying property numbers ................Error! Bookmark not defined.Renaming property designations ..........Error! Bookmark not defined.Check runs / Message management ....Error! Bookmark not defined.Report generation .................................Error! Bookmark not defined.

    Creating ......... Error! Bookmark notdefined.Drawing a terminal strip with motorand placing a dynamic terminaldiagram form on the page ...... Error!Bookmark not defined.

  • 5/26/2018 Eplan Electric p8 Basic 2

    5/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 4/213

    Updating the output when openingthe page ......... Error! Bookmark not

    defined.Labeling ......... Error! Bookmark notdefined.Outputting a bill of materials to MSExcelError! Bookmark not defined.

    Data transfer .........................................Error! Bookmark not defined.

    Entire project . Error! Bookmark notdefined.Importing individual master data........ Error! Bookmark not defined.

    Notes Pad ............................................. Error! Bookmark not defined.

  • 5/26/2018 Eplan Electric p8 Basic 2

    6/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 5/213

    1. PROJECT MANAGEMENT DATABASE

    Project management displayed all the information contained in a project. Here you

    can manage your project files such as:

    a) Import / Export project.b) Back up / Restore project.c) Creating Basic Project.d) Creating Project Template.e) Sending Project via email.f) Compress and Reorganize project.g) Opening, rename, copying and delete project.h) Editing Project Properties.i) Outputting Project Information.

    PROJECT > MANAGEMENT

    Import / Export project.

    Eplan project can be import and export ( in .epj format) in the project management.

    To import a project

    Project > Management > Organize > Import

  • 5/26/2018 Eplan Electric p8 Basic 2

    7/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 6/213

    Looks for a .epj format files and click Open

    Select OK

    Process of importing

  • 5/26/2018 Eplan Electric p8 Basic 2

    8/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 7/213

    Here you go, your newly imported project

    To export a project

    Project > Management > Choose A Project > Organize > Export

  • 5/26/2018 Eplan Electric p8 Basic 2

    9/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 8/213

    Choose the directory where you want to output you exported project. Press OK afteryou choose the directories.

    Eplan project exported.

  • 5/26/2018 Eplan Electric p8 Basic 2

    10/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 9/213

    Back up / Restore project.

    To back up a project

    Project > Management > Choose A Project > Organize > Back up

    Select the method you want use to back up your files and the medium where youwant your back up to be stored. Press OK when you done.

  • 5/26/2018 Eplan Electric p8 Basic 2

    11/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 10/213

    Saving Method

    Store Additionally Backing up copies the project to the target data

    medium. In other words, the project remainsavailable in exactly the same form.

    File Off for external processing The file-off function is used to copy the project tothe target data medium for additional external

    editing or modification. The original project is then

    locked to prevent any modifications being made to

    it. Thus, only the filed-off project can be changed.

    You can, however, open the original project on a

    read only basis.

    Archive Archiving is used to file completed projects to atarget data medium. The entire original project is

    deleted from the current hard disk, leaving only an

    information file. Archived projects are also

    identified by a special symbol in the project

    selection windows.

    Press OK

  • 5/26/2018 Eplan Electric p8 Basic 2

    12/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 11/213

    Process Of backing up

    Your selected project has successfully been back up.

  • 5/26/2018 Eplan Electric p8 Basic 2

    13/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 12/213

    To restore a project

    Project > Management > Organize > Restore

    Select the directory where you saved your back up files then press OK

  • 5/26/2018 Eplan Electric p8 Basic 2

    14/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 13/213

    Press yes to overwrite the existing files with the back up files.

    Process of restoring the files

    Press OK

  • 5/26/2018 Eplan Electric p8 Basic 2

    15/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 14/213

    Creating Basic Project.

    When you create a basic project from an existing project, the pages and all project-specific settings are saved in the basic project. A basic project has the ebp suffix.

    When you create a project from a basic project, the following settings from the basicproject are adopted in the new project:

    All project related settings. Project related settings are the settings underOptions > Settings > Projects > "Project name".Schemes for the page and device structure.

    All pages. All pages in the basic project are adopted in the new project. Sincethe pages are adopted you cannot change the page structure in the newly

    created project.

    Project > Management > Choose A Project > Extra > Create Basic Project

  • 5/26/2018 Eplan Electric p8 Basic 2

    16/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 15/213

    Create a new name for your project template and click save.

    Project template

    When you create a project template from an existing project, all project-specificsettings and the schemes for the project structure are saved. A project template hasthe ept suffix.

    When you create a project from a project template, the following data and settingsare adopted:

    All project related settings. Project related settings are the settings underOptions > Settings > Projects > "Project name".Schemes for the page and device structure. Since no pages are adopted fromthe project template, you can change both the page and device structure inthe newly created project.

  • 5/26/2018 Eplan Electric p8 Basic 2

    17/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 16/213

    Project > Management > Choose A Project > Extra > Create Project Template.

    Create a new name for your project template and click save

  • 5/26/2018 Eplan Electric p8 Basic 2

    18/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 17/213

    Sending Project via email.

    Project > Management > Choose A Project > Organize > Send By Email

    Click Yes

  • 5/26/2018 Eplan Electric p8 Basic 2

    19/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 18/213

    Process of sending e-mail.

    Link to e-mail account. Type in the e-mail address and sent

  • 5/26/2018 Eplan Electric p8 Basic 2

    20/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 19/213

    Compress and Reorganize project.

    This function irretrievably removes any deleted pages from the project and removes

    gaps in the database. The project can be examined at the same time for dataconsistency.

    To compress a project.

    Project > Management > Choose A Project > Organize > Compress

  • 5/26/2018 Eplan Electric p8 Basic 2

    21/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 20/213

    Click Yes

    Click Yes

    Process of compressing project

  • 5/26/2018 Eplan Electric p8 Basic 2

    22/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 21/213

    Click Close

    To reorganize the project

    Project > Management > Choose A Project > Organize > Reorganize

  • 5/26/2018 Eplan Electric p8 Basic 2

    23/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 22/213

    Click Yes

    Process of reorganize the project.

  • 5/26/2018 Eplan Electric p8 Basic 2

    24/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 23/213

    Opening, rename, copying and delete project

    Opening a project

    Project > Management > Choose A Project > Organize > Open

  • 5/26/2018 Eplan Electric p8 Basic 2

    25/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 24/213

    Renaming a project

    Project > Management > Choose A Project > Organize > Rename

    Type in a new project name.

    Your project has been rename

  • 5/26/2018 Eplan Electric p8 Basic 2

    26/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 25/213

    Copying a project

    Project > Management > Choose A Project > Organize > Copy

  • 5/26/2018 Eplan Electric p8 Basic 2

    27/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 26/213

    Click OK

    Your project has been copied to a new files.

  • 5/26/2018 Eplan Electric p8 Basic 2

    28/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 27/213

    Deleting a project

    Project > Management > Choose A Project > Organize > Delete

    Click Yes to all

  • 5/26/2018 Eplan Electric p8 Basic 2

    29/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 28/213

    Editing Project Properties.

    Project > Management > Choose A Project > Edit

    Change your properties accordingly and click save after the modification.

  • 5/26/2018 Eplan Electric p8 Basic 2

    30/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 29/213

    Outputting project information

    Project > Management > Choose A Project > Extra > Output Project

    Information

    Click OK

  • 5/26/2018 Eplan Electric p8 Basic 2

    31/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 30/213

    Overview Of report.

  • 5/26/2018 Eplan Electric p8 Basic 2

    32/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 31/213

    2. PLOT FRAMES

    Defines the logical structure of the schematic, that is, the assignment of a plot frame

    to a page determines the header, page size, and the division into rows and columns.There are additional special texts available, the row and column texts.

    Copying Existing Plot Frames

    Utilities > Master data > Plot frame > Copy

  • 5/26/2018 Eplan Electric p8 Basic 2

    33/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 32/213

    Select the plot frame you want to copy, create a new name youre your copied plotframe and then click open.

  • 5/26/2018 Eplan Electric p8 Basic 2

    34/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 33/213

    Creating New Plot Frames

    Utilities > Master data > Plot frame > New

  • 5/26/2018 Eplan Electric p8 Basic 2

    35/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 34/213

    Create a new name for your Plot Frame and Click Save.

    Set the setting for your new plot frame and click OK

    To create what

  • 5/26/2018 Eplan Electric p8 Basic 2

    36/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 35/213

    To displayed information in the plot frame, go to

    Insert > Special Text > Project Properties/ Page Properties

    By pressing the icon, you can choose the properties available.

  • 5/26/2018 Eplan Electric p8 Basic 2

    37/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 36/213

    Choose the properties you want to displayed and click OK

  • 5/26/2018 Eplan Electric p8 Basic 2

    38/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 37/213

    Make sure the properties you choose is correct. Then Press OK

    Place where you want the properties to be appear in the plot frame.

  • 5/26/2018 Eplan Electric p8 Basic 2

    39/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 38/213

    Once the plot frames is completed, just close the screen. Its auto save.

    3. Symbols

    Utilities > Master data > Symbol library > New

    Firstly, if you are created a symbol in the totally new symbol libraries, follow the step as

    below. If you want to create a symbol in a existing symbol libraries, ignore step 1, 2 and 3

    below.

  • 5/26/2018 Eplan Electric p8 Basic 2

    40/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 39/213

    Create a name for your symbol libraries

    Click OK

  • 5/26/2018 Eplan Electric p8 Basic 2

    41/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 40/213

    To create a new symbol,

    Utilities > Master data > Symbol > New

    Select a variant for the symbol and click OK

  • 5/26/2018 Eplan Electric p8 Basic 2

    42/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 41/213

    Type in a symbol name and the symbol description and click the icon to definethe symbol categories.

  • 5/26/2018 Eplan Electric p8 Basic 2

    43/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 42/213

    Select the category your symbol will fall into. Let said that I want to create a coil, goto Coils, contacts, and protective circuits, select the appropriate attributes for theparticular symbols.

  • 5/26/2018 Eplan Electric p8 Basic 2

    44/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 43/213

    Select OK

  • 5/26/2018 Eplan Electric p8 Basic 2

    45/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 44/213

    The button is the insertion point of the symbol, you can used the free graphicsdrawing to help you to designed the symbol.

    Example of a designed symbols.

    Free Graphics Drawing

  • 5/26/2018 Eplan Electric p8 Basic 2

    46/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 45/213

    Now right click on top frame toolbar and activate the symbol editor toolbar.

    the connection point for the symbol.

    Symbol Editor Toolbar

  • 5/26/2018 Eplan Electric p8 Basic 2

    47/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 46/213

    To displayed the properties such as technical characteristics, counter, identifierwhen you insert your symbol in your design in future,

    Insert > Properties Text

    Or

    In theplacement of properties dialog, press the button.

  • 5/26/2018 Eplan Electric p8 Basic 2

    48/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 47/213

    Choose what are the properties you want to displayed and click OK.

  • 5/26/2018 Eplan Electric p8 Basic 2

    49/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 48/213

    Once OK

    Press the OK button.

  • 5/26/2018 Eplan Electric p8 Basic 2

    50/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 49/213

    To have different variants in the symbol

    Go to Utilities > Master Data > Symbol > New Variant.

    Choose the variant you want and click OK

  • 5/26/2018 Eplan Electric p8 Basic 2

    51/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 50/213

    Select how you want the new variant to be rotated. Example Variant A rotated by 90 0.Continue the same step for different type of variant.

  • 5/26/2018 Eplan Electric p8 Basic 2

    52/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 51/213

    Click the button if you have satisfied with your symbol.

    Now go to

    Option > Setting > Projects > Project Name > Management > Symbol Libraries

  • 5/26/2018 Eplan Electric p8 Basic 2

    53/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 52/213

    Press the button,

  • 5/26/2018 Eplan Electric p8 Basic 2

    54/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 53/213

    Select the symbol libraries and click Open.

    Press OK

  • 5/26/2018 Eplan Electric p8 Basic 2

    55/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 54/213

    Now go to

    Insert > Symbol

    Press the button,

    Press button,

  • 5/26/2018 Eplan Electric p8 Basic 2

    56/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 55/213

    Type In the symbol libraries name and the description name, Click OK once youhave finished.

  • 5/26/2018 Eplan Electric p8 Basic 2

    57/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 56/213

    Now pressed the button in the value column.

    Tick in the newly created symbol libraries. Press OK after you have completed

  • 5/26/2018 Eplan Electric p8 Basic 2

    58/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 57/213

    Press OK

    Here you go, your newly created symbol.

  • 5/26/2018 Eplan Electric p8 Basic 2

    59/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 58/213

    4. Forms

    Copying Existing Forms

    Utilities > Master Data > Form > Copy.

  • 5/26/2018 Eplan Electric p8 Basic 2

    60/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 59/213

    Select the type of form type.

  • 5/26/2018 Eplan Electric p8 Basic 2

    61/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 60/213

    Select the form you want to copy and click Open.

    Create a name for your form.

  • 5/26/2018 Eplan Electric p8 Basic 2

    62/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 61/213

    If you want to modified the text properties;

    Insert > Special text > Project properties or Page properties.

    Choose what information you want to displayed by pressing the button.

  • 5/26/2018 Eplan Electric p8 Basic 2

    63/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 62/213

    Select the type of properties you want to displayed in the form, click OK after youhave selected the properties

  • 5/26/2018 Eplan Electric p8 Basic 2

    64/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 63/213

    Press OK

    Click where you the properties text to be displayed when you generate the report onthe future.

  • 5/26/2018 Eplan Electric p8 Basic 2

    65/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 64/213

    Close the window after you have done with your modification.

    Creating New Forms

    Utilities > Master Data > Form > New

  • 5/26/2018 Eplan Electric p8 Basic 2

    66/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 65/213

    Select the type of form you want to modified,

    Create a new name for your form. Click saveafter you have done with your setting.

  • 5/26/2018 Eplan Electric p8 Basic 2

    67/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 66/213

    Free Graphics Line Toolbar

    Change the setting accordingly and click OK after you have done with your setting.

    Use the free graphics line toolbar to design your form.

  • 5/26/2018 Eplan Electric p8 Basic 2

    68/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 67/213

    To insert the text properties, go to

    Insert > Special text > Project Properties / Page Properties

    Click the to choose the properties you want to displayed when you generate theform.

  • 5/26/2018 Eplan Electric p8 Basic 2

    69/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 68/213

    Select the properties you want to output and click OK

  • 5/26/2018 Eplan Electric p8 Basic 2

    70/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 69/213

    Press OK

    Place where you want to output in the form.

  • 5/26/2018 Eplan Electric p8 Basic 2

    71/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 70/213

    Close the window after you have modified the form.

    Defining Form Properties

    Form type:

    Select the desired form type from the drop-down list (such as "Terminal connectiondiagram", "Table of contents", "Order list", etc.). This property defines the type ofform. Each form type is assigned a particular ID. This is used internally to generatethe list of properties available (placeholder texts) that can be used during the editingof the form. Thus each form has a specific list of available fields. The form type ID isalso used to generate the list of forms which are available in the "Reports" dialog forthe generation of a particular document. For instance, if you want to generate adevice tag list, only the forms present which are designated as device tag list formsare offered for selection.

    Property name / Value list:

    The available properties are displayed depending on the selected category. Some ofthem, for example "Company code" and "Modification date" have already beenassigned values that can't be changed. Others, for example "Description" and"Version", can be assigned values or their existing values can be changed.

    The following properties are particularly important:

    Name (form, plot frame): "Data" category, file name, write-protectedDescription (form, plot frame): "Data" category, string (multi-lingual)

    Plot frame to edit form: "Settings" category, stringForm handling: "Settings" category, drop-down list; specifies the form as astatic or dynamic form.Regenerate main sub-header: "Settings" category, special dialogNumber of columns / rows: "Settings" category, integer; maximum number ofcolumns / rows generated on a pageColumn width / row height: "Settings" category, decimal (in "mm"); specifiesthe width of columns / height of rows in the form.

  • 5/26/2018 Eplan Electric p8 Basic 2

    72/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 71/213

    Form structure: "Settings" category, drop-down list; order in which rows andcolumns are filled in. The process always starts in the upper left. "By row"means that first all cells of a row are filled in before switching to the next row.In this case, bridges are displayed vertically. "By column" means that first allcells of a column are filled in before switching to the next column. In this case,

    bridges are displayed horizontally.Dynamic row adjustment: "Settings" category, check box. If indirect propertiesare indexed with 0, then the values for all (meaningful) indices are printedtogether. This is generally done using one-row lists separated by semicolons.In forms, however, you have the option of printing these values asindependent elements (rows / columns).Example: Indirect goal.Name(0) gives M1;M2;X1:2. If dynamic rowadjustment is activated, then these four target names are printed one underthe other.Jumpers: Height of first level: "Settings" category, decimal (in "mm"); height ofa jumper in the first level in the terminal diagram. The distance to the next

    jumper is defined by the property "Jumpers: Spacing".Jumpers: Distance: "Settings" category, decimal (in "mm"); distance betweentwo jumpers in neighboring levels. (The height of the first jumper is defined bythe property "Jumpers: Height of first level".)Jumpers: Radius of connecting points: "Settings" category, decimal (in "mm");since the nodes of jumpers are graphically shown in the terminal diagram witha small filled circle, you specify the radius of this circle with this property (insoftware coordinates). (Start and end "legs" don't have dots.)Jumpers: Radius for nodes: "Settings" category, decimal (in "mm"); if jumpersare shown graphically in the terminal diagram, then a small filled circle is seton the base line on each "leg" of the jumper. The radius of this circle is

    specified with this property (in software coordinates).Jumpers: Height of external wire jumper: "Settings" category, decimal (in"mm"); height of an internal / external jumper in the first level in the terminaldiagram. If the matching property is not set, this is used instead of "Jumpers:height of first level".Jumpers: Height of internal / external wire jumper: "Settings" category,decimal (in "mm"); distance between two internal / external wire jumpers inneighboring levels. If the property is not set, "Jumpers: distance" is used.Format for automatic page description: "Settings" category, special dialog;format for the page description automatically assigned when generatingreport lists.

    Assignment 'Index to graphic': "Settings" category, special dialog;configuration property which assigns each graphic an index value; theselection of graphics is this done in the "Fixed graphic" placeholder by givingthe index value.

    Assignment: Function definition to graphic: "Settings" category, special dialog;assignment of a terminal type number to a symbol variant. Used whengenerating a page in order to create a fixed symbol graphic.

  • 5/26/2018 Eplan Electric p8 Basic 2

    73/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 72/213

    Connection diagram: Suppress jumper targets: "Settings" category, integer;determines what type of jumper targets is not to be displayed in connectionpoint diagrams:0 = Show all jumper targets1 = Hide saddle jumper targets, show wire jumper targets

    2 = Suppress saddle and wire jumper targets.Connection diagram: Number of graphical levels (internal / external):Category "Settings", IntegerConnection diagram: New row in the case of graphical overlapping: "Settings"category, check box; if this property is set, then in case of overlapping ofgraphical views in connection diagrams, a new row is started or an empty rowinserted. An overlap occurs when one of the relevant graphics layers does notcontain the same device as the next record on the same level. More compactviews can be implemented in connection diagrams in this way. The properties"Connection diagram: Number of graphical levels (internal) / (external)" mustbe set correctly.

    Structure identifier overview: "Settings" category, drop-down list for selectionof structure identifiers to be displayed in the form.Combine multi-level terminals: "Settings" category, check box; useful forterminal line-up diagrams.

    Assignment of property / value to graphic: "Settings" category, special dialog;assignment of a property and / or value to a symbol variant.Jumper display: "Settings "category, drop-down list (line, angle)Jumpers: Line thickness: "Settings" category, decimal (in "mm")Jumpers: Number of levels: Category "Settings", IntegerNumber of cables...: Category "Settings", integerCable distance...: "Settings" category, decimal (in "mm")

    Horizontal symbol distance: "Settings" category, decimalNumber of adjacent symbols: "Settings" category, integer "1-X"Grid: "Settings " category, string (default: 4 mm)Modification date (manual): "Revision" category, dateVersion: "Revision" category, stringCompany code: "Data" category, string, write-protected

  • 5/26/2018 Eplan Electric p8 Basic 2

    74/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 73/213

    Dynamic Forms

    Form in which the graphics can be changed (e.g., the number of lines: only those

    are displayed which have data filled in, no empty ones), that is, the graphics areadapted to the actual number of lines. In this kind of form, header, data, and footerscan also be determined within one page.

    Check the form to be modified

  • 5/26/2018 Eplan Electric p8 Basic 2

    75/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 74/213

    Copy and paste in the same place, then rename to another form name, eg F04.f03

  • 5/26/2018 Eplan Electric p8 Basic 2

    76/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 75/213

    Highlight the unwanted table, delete it.

    Click on the page, Open the page properties,(shift + D)Go to properties and change the setting as follows:

    1) Columns change to : 1 ( 1 column)2) Horizontal symbols : 25 (cross-ref space)3) Number of adjacent : 20 (component in a row)4) Form handling : Dynamic (auto lines)

  • 5/26/2018 Eplan Electric p8 Basic 2

    77/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 76/213

    Go to form and edit the properties of the forms

    Change the form accordingly .

  • 5/26/2018 Eplan Electric p8 Basic 2

    78/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 77/213

  • 5/26/2018 Eplan Electric p8 Basic 2

    79/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 78/213

    Draw a normal lines

    From the Data area, Click the area that require repeated.

  • 5/26/2018 Eplan Electric p8 Basic 2

    80/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 79/213

    Then close and proceed as below.

  • 5/26/2018 Eplan Electric p8 Basic 2

    81/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 80/213

    5. Bus Topologies

  • 5/26/2018 Eplan Electric p8 Basic 2

    82/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 81/213

    6. Location Box

    Adding Location Boxes

    Everything inside a location box is allocated to a different DIN group from that whichis defined in the page properties. The components then have the same relationshipto the location box as they normally have to the page. This assumption of the DTalso occurs if only identifier blocks like installation and location are entered in acomponent in the location box.

    Insert > Box / connection point / mounting panel > Location box

    Draw the rectangle representing the box.

  • 5/26/2018 Eplan Electric p8 Basic 2

    83/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 82/213

    Enter the item data in the location box specific Properties dialog.

  • 5/26/2018 Eplan Electric p8 Basic 2

    84/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 83/213

    In the Identifier tab, click [...] in the Full DT field.

    Accept the default for the DT or make new entries for the identifier blocks ifyou would like to modify the structure.

    Click [OK].

  • 5/26/2018 Eplan Electric p8 Basic 2

    85/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 84/213

    Click OK

  • 5/26/2018 Eplan Electric p8 Basic 2

    86/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 85/213

    Specify the position for the new identifier in the Place identifiersdialog usingthe buttons then click OK

  • 5/26/2018 Eplan Electric p8 Basic 2

    87/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 86/213

    7. Multi-User Access

  • 5/26/2018 Eplan Electric p8 Basic 2

    88/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 87/213

    8. User Rights Management

    Managing Users

    The rights management allows you to create users and assign them to particularuser groups. You can also subsequently edit or delete users.

    Create users

    Utilities > Rights management

    To the left of the Rights management dialog, select the User folder, and click[New].

  • 5/26/2018 Eplan Electric p8 Basic 2

    89/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 88/213

    In the User dialog, enter a name and short description of the new user.

    You can assign a password in the Password field. To avoid typing errors onentry, you must enter the password a second time into the Confirm passwordfield.

    Click [OK].

    Assign the user to one or more groups as described in the section "EditingUsers".

  • 5/26/2018 Eplan Electric p8 Basic 2

    90/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 89/213

    Edit users

    Utilities > Rights management

    To the left of the Rights management dialog, select the User folder.

  • 5/26/2018 Eplan Electric p8 Basic 2

    91/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 90/213

    Select a (self-defined) user name in the right-hand field and click [Edit].

    In the User dialog, change the name, description and password and then click[OK].

  • 5/26/2018 Eplan Electric p8 Basic 2

    92/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 91/213

    Delete users

    Utilities > Rights management

    To the left of the Rights management dialog, select the User folder.

  • 5/26/2018 Eplan Electric p8 Basic 2

    93/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 92/213

    Select a (self-defined) user name in the right-hand field and click [Delete].

  • 5/26/2018 Eplan Electric p8 Basic 2

    94/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 93/213

    Assign users to groups

    Utilities > Rights management

    In the Rights management dialog, click the plus sign next to the User folderto open the folder and select a user name.

  • 5/26/2018 Eplan Electric p8 Basic 2

    95/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 94/213

    Select the check box corresponding to the user groups for which you wish theuser to be a member of.

    Managing User Groups

    The rights management allows you to create user groups and assign particularediting rights to them. You can also subsequently edit or delete user groups.

    Create user groups

    Utilities > Rights management

    To the left of the Rights Management dialog, select the Groups folder, andclick [New].

  • 5/26/2018 Eplan Electric p8 Basic 2

    96/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 95/213

    In the Group dialog, enter a name and short description of the allowed editingrights of the new user group.

    Click [OK].

    Assign editing rights to the group as described under "Editing user groups".

  • 5/26/2018 Eplan Electric p8 Basic 2

    97/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 96/213

    Edit user groups

    Utilities > Rights management

    To the left of the Rights management dialog, select the Group folder.

    Select a (self-defined) user group in the right-hand field and click [Edit]. In theGroup dialog, change the name or description. Click [OK].

  • 5/26/2018 Eplan Electric p8 Basic 2

    98/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 97/213

    Delete user groups

    Utilities > Rights management

    To the left of the Rights management dialog, select the Group folder. Select a(self-defined) user group in the right-hand field and click [Delete].

  • 5/26/2018 Eplan Electric p8 Basic 2

    99/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 98/213

    Assign editing rights to groups

    in the Rights management dialog, click the plus sign next to the Group folder

    to open the folder and select a user group.

    Select the check box in front of the user groups in which the current user is tobe a member. Click the plus sign to open the subordinate rights. Click [OK].

  • 5/26/2018 Eplan Electric p8 Basic 2

    100/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 99/213

    Logging on or Changing Users

    Log on users

    The Logon dialog is automatically displayed when EPLAN starts.

    Enter the user name and password and click [OK].

    Switch users

    Select the menu item Project > Switch user.

    Enter the user name and password into the Logon dialog and click [OK].

  • 5/26/2018 Eplan Electric p8 Basic 2

    101/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 100/213

    9. Revision Management

    Completing Projects and Pages

    In EPLAN, projects can be completed at any time. The project is then write-protectedand can no longer be changed. A completed project is stored in the project directory

    with the extension *.elr.

    Select the menu item Utilities > Revision control > Complete project.

    Click [Yes] in the message window in order to use the comments on therevision as the description for the page modification. (If you click [No], theprocess will be canceled, and you can complete the pages manually).

    Complete pages

    Select the project or the modified pages in the page overview, and select themenu item Utilities > Revision control > Complete pages.

  • 5/26/2018 Eplan Electric p8 Basic 2

    102/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 101/213

    Generating Revisions

    Utilities > Revision control > Generate revision

    In the Generate revision dialog, enter a name for the revision in the Revisionname field. In the Commentfield you can enter a short description of the revision,but the field may also be left blank. Click [OK].

  • 5/26/2018 Eplan Electric p8 Basic 2

    103/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 102/213

    Generating Comparison Projects

    Utilities > Revision control > Generate comparison project

    In the Generate comparison project dialog, enter a name for the comparisonproject in the Project name field.

    In the Comment field you can enter a short description of the comparisonproject, but the field may also be left blank.

    Select the check box Generate temporary comparison project if you wouldlike to generate a non-write-protected project that you can delete again later.

    Click [OK].

  • 5/26/2018 Eplan Electric p8 Basic 2

    104/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 103/213

    Comparing Projects

    Differences between two projects are registered by comparing particular properties

    with one another. In the Compare projects dialog, you can determine whichprojects will be compared. The properties to be compared are determined in theComparisonsettings dialog. If the value of the properties is identical for twoprojects, then no difference is registered between them.

    Select the desired project in the page navigator and select the menu itemUtilities > Revision control > Compare projects.

    In the Compare projects dialog, select the check box Show only associatedcomparison projects.

    In the list, select Compare with to select the comparison project you wouldlike to compare with the currently opened project.

    In the Comparison settingsfield, select the scheme which determines thesettings for the comparison. (If you have not stored your own schemes, then

    only the standard scheme will be offered here. In this case create a newscheme by Specifying comparison settings.)

    In the Text field, enter the text to be used to mark the revision changes in theproperties.

    Click [OK].

  • 5/26/2018 Eplan Electric p8 Basic 2

    105/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 104/213

    Removing Revision Markers

    You can remove revision markers created via change tracking or a project

    comparison from the project separately.

    Utilities > Revision control > Delete revision markers

    In the Delete revision markers dialog, select which markers you would like to

    delete: Check the corresponding check boxes. Click OKafter you have done

  • 5/26/2018 Eplan Electric p8 Basic 2

    106/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 105/213

    Removing Write Protection

    Completed projects and comparison project are always write-protected. Only

    temporary comparison projects are not write-protected. However, it is possible toremove the write protection if necessary.

    Utilities > Revision control > Remove write protection

  • 5/26/2018 Eplan Electric p8 Basic 2

    107/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 106/213

    10. Translation

    Setting Up Translation Database

    Opening a Dictionary

    As standard, EPLAN dictionaries are stored in the ..\Translation directory.Select Utilities > Translation > Edit dictionary > Management tab.

  • 5/26/2018 Eplan Electric p8 Basic 2

    108/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 107/213

    Click [...] next to the Dictionaries field.

    Select the directory where the dictionary is located. Select the Microsoft Access-

    Datenbanken (*.mdb)file type and then select the desired file.

  • 5/26/2018 Eplan Electric p8 Basic 2

    109/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 108/213

    Creating a Dictionary

    You can create and manage multiple dictionaries. Select the appropriate dictionary

    for each of your projects.

    Utilities > Translation > Edit dictionary > Management tab

    Select [Extras] > New.

  • 5/26/2018 Eplan Electric p8 Basic 2

    110/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 109/213

    To create a new database for the dictionary, enter a file name into the File

    name field and select the Microsoft Access databases (*.mdb) file type.

    Click [Save].

  • 5/26/2018 Eplan Electric p8 Basic 2

    111/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 110/213

    Add dictionary language

    In the Management tab, use [...] to select the dictionary to which you wish to

    add a dictionary language.

    Click (New) next to the Dictionary language field.

  • 5/26/2018 Eplan Electric p8 Basic 2

    112/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 111/213

    One after the other, select all of the languages that should be available in thedictionary.

  • 5/26/2018 Eplan Electric p8 Basic 2

    113/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 112/213

    Delete dictionary language

    In the Management tab, use [...] to select the dictionary from which you wish

    to remove a dictionary language.

    Select a language in the Dictionary languages field.

  • 5/26/2018 Eplan Electric p8 Basic 2

    114/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 113/213

    Click (Delete).

  • 5/26/2018 Eplan Electric p8 Basic 2

    115/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 114/213

    Language Translation

    Utilities > Translation > Settings

  • 5/26/2018 Eplan Electric p8 Basic 2

    116/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 115/213

    In the project tabs, under display column, select new button

  • 5/26/2018 Eplan Electric p8 Basic 2

    117/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 116/213

  • 5/26/2018 Eplan Electric p8 Basic 2

    118/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 117/213

    To export full sentences select the Translate whole sentences only checkbox.

    To export individual words deselect the Translate whole sentences onlycheck box.

  • 5/26/2018 Eplan Electric p8 Basic 2

    119/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 118/213

    Exporting missing word

  • 5/26/2018 Eplan Electric p8 Basic 2

    120/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 119/213

    Create a file name, select the location where you want the files to be saved and clickSave

    Select the language files

  • 5/26/2018 Eplan Electric p8 Basic 2

    121/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 120/213

    Importing Text Into Database

    Once you have translate the output files,

    Go to Utilities > Translation > Edit Dictionary

  • 5/26/2018 Eplan Electric p8 Basic 2

    122/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 121/213

    Now, under management tab, go to Extra > Import

  • 5/26/2018 Eplan Electric p8 Basic 2

    123/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 122/213

    Select the translated files and click Open.

    Select the reference language

  • 5/26/2018 Eplan Electric p8 Basic 2

    124/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 123/213

    Auto Correct / Auto Complete

    AutoComplete:

    If the check box is selected, words will be automatically completed while you type.

    Utilities > Translation > Setting

  • 5/26/2018 Eplan Electric p8 Basic 2

    125/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 124/213

    Under User tab, In the Input column, select AutoComplete

  • 5/26/2018 Eplan Electric p8 Basic 2

    126/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 125/213

    AutoCorrect:

    If the check box is selected, all of the words that you have specified in the AutoCorrect tab

    will be replaced in the first display language by their replacement text.

    Utilities > Translation > Setting

  • 5/26/2018 Eplan Electric p8 Basic 2

    127/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 126/213

    Under User tab, In the Input column, select AutoCorrect.

  • 5/26/2018 Eplan Electric p8 Basic 2

    128/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 127/213

    11. Advance Setting

    In the Settings dialog, you can view and edit all settings for the Project, User,

    Workstation, or Company categories.

    Project Setting

  • 5/26/2018 Eplan Electric p8 Basic 2

    129/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 128/213

    12. System Messages

    Calling up System Messages

    When you open a project, the System messagesdialog lists errors which occurduring the program run in the currently opened project.

    You can open the system messages at any time, even when no project is currentlyopen.

    Utilities > System messages.

  • 5/26/2018 Eplan Electric p8 Basic 2

    130/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 129/213

  • 5/26/2018 Eplan Electric p8 Basic 2

    131/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 130/213

    Storing System Messages

    You can save the displayed system messages as a text file. You define the directory

    for the file in the workstation settings. The file name EplLog.txt is predefined bythe program.

    Select the menu item Utilities > System messages.

  • 5/26/2018 Eplan Electric p8 Basic 2

    132/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 131/213

    Click [Save] in the dialog.

  • 5/26/2018 Eplan Electric p8 Basic 2

    133/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 132/213

    13. Change Of Standard

    Replacing Symbol Libraries and Symbols - Changing Standards

    You can replace basic symbol libraries, symbol libraries, and individual symbols. Thebasic symbol library contains the symbols for the basic symbol preview. Whenexchanging the basic symbol libraries and symbol libraries, the source data is savedin the target project. Individual symbols are replaced there.

    Utilities > Change of standard > Project tab > [Next] > Rotation / mirroringtab > [Next]

    Assign target symbol libraries

    In the Master data tab in the Name column select the symbol library to bereplaced.

  • 5/26/2018 Eplan Electric p8 Basic 2

    134/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 133/213

    Within the same row, click [...] in the New name column.

  • 5/26/2018 Eplan Electric p8 Basic 2

    135/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 134/213

    In the Select Symbol Library dialog, select the symbol library to be used forthe target project and click [Open].

  • 5/26/2018 Eplan Electric p8 Basic 2

    136/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 135/213

    To assign the entire symbol library click [Next] in the Master data tab and dothe same in the Symbols tab.

  • 5/26/2018 Eplan Electric p8 Basic 2

    137/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 136/213

    To assign the source symbol library symbols to the target symbol librarysymbols, select the Individual assignment check box in the Master data taband click [Next].

  • 5/26/2018 Eplan Electric p8 Basic 2

    138/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 137/213

    In the Symbols tab in the Scheme column select an assignment scheme.

    Click [Next].

  • 5/26/2018 Eplan Electric p8 Basic 2

    139/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 138/213

    14. Single Line Diagram / Overview

    Drawing Schematics in Single-line RepresentationFor the single-line display of schematics, you can use pages with a special pagetype. The placed symbols are connected together via autoconnecting. Using aconnection definition point, you can display the number of conductors in the cable.

    You have opened a project.

    Page > New

  • 5/26/2018 Eplan Electric p8 Basic 2

    140/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 139/213

    In the New page dialog, select Schematic single-line from the drop-down listin the Page type field.

  • 5/26/2018 Eplan Electric p8 Basic 2

    141/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 140/213

    Place the symbol

    Select Insert > Symbol.

  • 5/26/2018 Eplan Electric p8 Basic 2

    142/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 141/213

    Select the desired symbol from the Symbol selection dialog then press OK

    Place the symbol on the page in the graphical editor.

  • 5/26/2018 Eplan Electric p8 Basic 2

    143/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 142/213

    Place the connection definition point

    Select Insert > Connection definition point.

  • 5/26/2018 Eplan Electric p8 Basic 2

    144/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 143/213

    Place the connection definition point on the auto connection line betweenthe desired symbols in the graphical editor.

  • 5/26/2018 Eplan Electric p8 Basic 2

    145/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 144/213

    In the Properties dialog, in the Connection definition point tab, enterthe desired data then click OK

  • 5/26/2018 Eplan Electric p8 Basic 2

    146/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 145/213

    Synchronizing Data between Single-Line and Multi-Line Displays

    If you make a change to a multi-line object or a single-line object belonging to one,you can synchronize the objects with one another. You can be sure in this way that

    the change has been transferred to the matching counterpart object.

    1. Select the desired object.

    2. Select the menu item Utilities > Synchronization and, for a multi-line objectselect Multi-line --> single-line and overview, for a single-line object selectSingle-line --> multi-line and overview and for an object in the overview,select Overview--> multi-line and single-line.

  • 5/26/2018 Eplan Electric p8 Basic 2

    147/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 146/213

    Generating Connection

    To number the connection

    Project data > Connections > Numbering > Place

    Choose the type of setting.

  • 5/26/2018 Eplan Electric p8 Basic 2

    148/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 147/213

    Project Data > Connections > Numbering > Enter Designation

    Press OK

  • 5/26/2018 Eplan Electric p8 Basic 2

    149/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 148/213

  • 5/26/2018 Eplan Electric p8 Basic 2

    150/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 149/213

    Connection Setting

    Settings for connection numbering are saved in schemes. This way you can access

    previously specified settings at any time and even change them, if necessary.

    Project data > Connections > Numbering > Settings

    In the Settings: Connection numbering dialog, select a user-defined

    scheme from the drop-down list, or create a new scheme using (New).

  • 5/26/2018 Eplan Electric p8 Basic 2

    151/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 150/213

    In the Filter tab select the check box for the trade and connection type youwant to number. In the Placement tab select where and how often you want to placethe connection definition points on the connections.

  • 5/26/2018 Eplan Electric p8 Basic 2

    152/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 151/213

    In the Designation tab, define the format groups that are to be formattedtogether.

  • 5/26/2018 Eplan Electric p8 Basic 2

    153/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 152/213

    In the Display tab specify formatting for connection designations generated onthe connection definition point. Among these formatting options are, forexample, horizontal and vertical increments of the connection designation from

    the connection line, as well as text color, size, etc. Click OK after you have done.

  • 5/26/2018 Eplan Electric p8 Basic 2

    154/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 153/213

    Creating Format Groups

    Project data > Connections > Numbering > Settings

    In the Settings: Connection numbering dialog, select a user-defined

    scheme from the drop-down list, or create a new scheme using (New).

  • 5/26/2018 Eplan Electric p8 Basic 2

    155/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 154/213

    Move the Designation tab to the foreground and in the toolbar above the

    Format groups field, click (New).

  • 5/26/2018 Eplan Electric p8 Basic 2

    156/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 155/213

    In the Connection numbering: Formats dialog, in the Connection groupfield, select one of the predefined connection groups or the "Browse..." entry.

    If you selected "Browse..." and opened the Device tag list dialog, select oneof the DT's in the project and click [OK].

    In the Extent field specify the range of connections that are to receive thesame format for their connection designations. Select an entry from the dropdownlist.

    In the Available format elements field select a format element and move itover to the right using the arrow button into the list of selected formatelements.

  • 5/26/2018 Eplan Electric p8 Basic 2

    157/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 156/213

    Define the formatting in the subsequent dialog. If desired, you can change thesequence of the formatting elements using the arrow buttons. Click [OK] when youhave done with the setting.

    15. Managing Master Data

    Managing Master DataMaster data files to be edited or stored in the project can be opened in the standarddialog, which is in a default directory. You can specify settings for this via Options >Settings > User > Management > Directories.

    Actual storage and management depends on the type of master data in question, inwhich the program distinguishes between the management of:

    Parts dataFormsPlot framesMacrosSymbol libraries.

    If the specified form / plot frame is not in the master data pool, it can be found usingthe Complete project function and can even be automatically stored. If missingmaster data can't be found in the master data pool, a message is displayed.

  • 5/26/2018 Eplan Electric p8 Basic 2

    158/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 157/213

    Defining Master Data Directories

    Options > Settings > User > Management > DirectoriesThe paths to the required databases and files are defined in the defaults for

    directories when selecting or editing master data. This information is used by certainprogram elements and functions when particular data is required. The settings areuser dependent in order for you to manage and organize your own pool of masterdata.

    1. In the Projects field of the Settings: Directories dialog, click [...].

    In the Browse for Folder dialog select the desired drive and directory. Click [OK].

    Proceed this way for all further master data types with default directories thatyou would like to change. (The default after installing EPLAN is:\\\. Click [OK].

  • 5/26/2018 Eplan Electric p8 Basic 2

    159/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 158/213

    Master Data: Managing Parts Data

    In addition to the general parts database there is a project-related Parts projectdatabase, in which the parts data used in the project are managed separately. Data

    for a part is taken from the internal parts database and transferred to the project foreach part, even if only the part number is stored on the component in the graphicalediting at the time the part is selected.

    Project data can be synchronized later in both directions with the system masterdata. Furthermore, certain stored parts properties can be removed from the project.

    Synchronize project data with master data

    1. Open the project whose master data is to be synchronized.

    2. Select Utilities > Parts > Current project --> parts database.

  • 5/26/2018 Eplan Electric p8 Basic 2

    160/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 159/213

    Synchronize master data with project data

    1. Open the project whose master data is to be synchronized.

    Select Utilities > Parts > Parts database --> current project.

  • 5/26/2018 Eplan Electric p8 Basic 2

    161/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 160/213

    Delete stored part properties

    1. Open the project whose master data is to be synchronized.

  • 5/26/2018 Eplan Electric p8 Basic 2

    162/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 161/213

    Select Utilities > Parts > Delete stored properties.

    In the Delete stored parts properties dialog, select the Delete check box foreach part property that you would like to delete from the part stored in theproject. Click [OK].

  • 5/26/2018 Eplan Electric p8 Basic 2

    163/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 162/213

    Master Data: Managing Forms

    Forms are edited as individual files and added individually to the project as soon asthey are used in the project. This means: As soon as a form is selected for use in a

    project (e.g. on a page) the selected formif it does not already exist in the projectit is automatically stored. An original form is not deleted from the project whenanother form is selected, but rather it remains embedded even if it is no longer used.

    If the selected form is not in the master data pool it can be found via the menu itemUtilities > Master data > Complete current project and, if necessary,automatically corrected. If missing master data cannot be found in the master datapool, then an appropriate message is displayed.

    Store form in project

    Select Utilities > Master data > Form > Open.

  • 5/26/2018 Eplan Electric p8 Basic 2

    164/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 163/213

    Select the form to be edited in the Open forms dialog.

  • 5/26/2018 Eplan Electric p8 Basic 2

    165/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 164/213

    In the page navigator, select the page to which you would like to assign theform.

  • 5/26/2018 Eplan Electric p8 Basic 2

    166/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 165/213

    Select Popup menu > Properties.

  • 5/26/2018 Eplan Electric p8 Basic 2

    167/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 166/213

    If the Form name property is not yet in the list of properties, click (New)next to the Category field in the Properties group box of the Page propertiesdialog.

  • 5/26/2018 Eplan Electric p8 Basic 2

    168/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 167/213

    In the Property selection dialog select the Form name property. Then press OK

  • 5/26/2018 Eplan Electric p8 Basic 2

    169/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 168/213

    Open the drop-down list in the Value field for the Form name property.

  • 5/26/2018 Eplan Electric p8 Basic 2

    170/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 169/213

    Click [Browse]. Select the changed form in the Select form dialog then pressedOpen. Press OK after you have done with the setting.

  • 5/26/2018 Eplan Electric p8 Basic 2

    171/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 170/213

    If required, you can change the values of the other properties of the page. Click [OK]after you have done with the setting.

  • 5/26/2018 Eplan Electric p8 Basic 2

    172/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 171/213

    Form master data is referenced as follows:All forms used on pagesAll forms stored in the settings for reports (Options > Settings > Projects >

    "Project name" > Reports > Graphical output)All forms saved in the following function types: mounting panel objects,terminal and plug definition texts, cables

    Placed forms (e.g. enclosure legends).

    Master Data: Managing Plot Frames

    Plot frames are edited as individual files and added individually to the project assoon as they are used in the project. This means: As soon as a plot frame isselected for use in a project (e.g. on a page)if it does not already exist in the

    projectit is automatically stored. An original plot frame is not deleted from theproject when another plot frame is selected, but rather it remains embedded even ifit is no longer used.

    If the selected form is not in the master data pool, it can be found via the menu itemUtilities > Master data > Complete current project and, if necessary,automaticallycorrected. If missing master data cannot be found in the master data pool, then anappropriate message is displayed.

    Store plot frame in project

    Select Utilities > Master data > Plot frame > Open.

  • 5/26/2018 Eplan Electric p8 Basic 2

    173/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 172/213

    Select the plot frame to be edited in the Plot frame selectiondialog. Click Open

    In the page navigator, select the page to which you would like to assign theplot frame.

  • 5/26/2018 Eplan Electric p8 Basic 2

    174/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 173/213

    Select Popup menu > Properties.

  • 5/26/2018 Eplan Electric p8 Basic 2

    175/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 174/213

    If the Plot frame name property is not yet in the list of properties, click(New) next to the Category field in the Properties group box of the Pageproperties dialog.

  • 5/26/2018 Eplan Electric p8 Basic 2

    176/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 175/213

    In the Property selection dialog select the Plot frame name property. Click OKafter you have done.

  • 5/26/2018 Eplan Electric p8 Basic 2

    177/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 176/213

    Open the drop-down list in the Value field for the Plot frame name property.

  • 5/26/2018 Eplan Electric p8 Basic 2

    178/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 177/213

    Click [Browse]. Select the changed plot frame in the Select plot frame dialog. Afteryou have selected the frame, click Open. Select OK after you have done with thesetting.

  • 5/26/2018 Eplan Electric p8 Basic 2

    179/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 178/213

    Master Data: Managing Macros

    Macros are broken up in the project as soon as they are inserted. Data is thenundistinguishable from manually inserted individual elements. All data in a macro are

    referenced when stored (except foreign language texts).

    The name of the symbol library from which the macro was generated (drawn) isstored in the macro. This way the macro preview will use the correct symbol libraryfor the display.

    In the operating system layer, macros are individual files that can be sent to endcustomers, for example.

    Master Data: Managing Symbol LibrariesSymbols are compiled, edited, and managed in symbol libraries. The project settings

    (inherited by symbols, e.g. line thickness of the symbol) for the current project areused in managing the symbol libraries.

    Symbol selection (Insert > Symbol) only displays those symbols from the storedsymbol libraries and symbol libraries are identified by name (without the path) inprojects.

    Store symbol libraries (copy to the project)Symbol libraries are added to the project as soon as they are entered into the projectsettings, or they are opened or generated in the project.

    Options > Settings > Projects > "Project name" > Management > SymbolLibraries

    1. In the Settings: Symbol libraries dialog, click [...] in a column below Symbollibraries.

    2. In the Select symbol library dialog select the new symbol library.

    3. Click on [Open].

    4. If you have clicked [...] in the column of an already assigned symbol library,EPLAN checks whether the original symbol library and the newly selected oneare both compatible. If this is not the case, the process will be interrupted witha prompt. If the two symbol libraries are compatible, you have to confirm theexchange in the Exchange symbol libraries dialog. Click [Yes].

  • 5/26/2018 Eplan Electric p8 Basic 2

    180/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 179/213

    5. If you have clicked [...] in an empty column, the storage process isautomatically started.

    6. Select the Synchronize check box if the symbol library should be managed on

    a project basis.

    7. If necessary, change the preceding sign (the default is the first letter of thesymbol library) so that you can differentiate between the symbol libraries in thelist view in the Symbol selection if you select Popup menu > Name withpreceding sign.

    8. Proceed this way for all of the further symbol libraries that you would like tostore in the project.

    9. Click [OK].

    File off symbol libraries (delete from the project)Before deleting a symbol library from the settings, and therefore from the project, thelibrary is checked for symbols that are still used in the project. It is possible to deleteif the symbol library is not being used.

    Options > Settings > Projects > "Project name" > Management > Symbollibraries

    1. In the Settings: Symbol libraries dialog, select the symbol library that you

    would like to delete from the project.

  • 5/26/2018 Eplan Electric p8 Basic 2

    181/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 180/213

    Click (Delete). If symbols from the selected symbol library are still being used inthe project, click [OK] to confirm the prompt.

  • 5/26/2018 Eplan Electric p8 Basic 2

    182/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 181/213

    Master Data: Defining Form Settings

    Master data is stored on a project-related basis and can be synchronized with themaster data pool when opening, saving, or restoring the project. There are project

    settings especially for forms, which you can specify as follows:

    Options > Settings > Projects > "Project name" > Reports > Output to page

    1. In the Settings: Output to page dialog, open the Form drop-down list for thereporting type whose settings you would like to edit.

  • 5/26/2018 Eplan Electric p8 Basic 2

    183/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 182/213

    Click [Browse].

    3. Select the desired form in the Select form dialog. Only the data typeappropriate to the currently selected report type will be displayed under Filesof type.

    4. Select the Preview check box in order to display the graphic for the form thatis selected in the list.

    5. Click [Open].

    6. Select the Project related check box if the form should be managed on a

    project basis..

  • 5/26/2018 Eplan Electric p8 Basic 2

    184/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 183/213

    7. Specify additional settings for the form.

    8. Click [OK].

  • 5/26/2018 Eplan Electric p8 Basic 2

    185/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 184/213

    Synchronizing Master Data

    The master data (e.g. a symbol library) is not referenced, but rather stored in theproject, i.e. copied into the project. The storage of the master data being used thus

    occurs within the Project. Depending on the project settings specified under Options> Settings > Projects > "Project name" > Management > General , Options >Settings > Projects > "Project name" > Management > Symbol libraries, andOptions > Settings > Projects > "Project name" > Reports > Display / outputyou can, if necessary, manually start the synchronization of project master data withthe system-specific data.

    Synchronize individual master data objectsPreconditions:

    You have opened the project whose master data is to be synchronized.You have no editor open for working on master data (Plot frame editor, Form

    editor, etc.).Utilities > Master data > Synchronize current project

  • 5/26/2018 Eplan Electric p8 Basic 2

    186/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 185/213

    1. In the Synchronization of master data dialog click thecolumn heading in the tables in order to sort the data alphanumerically eitherascending or descending by column. For example, if you click the column

    Type, all entries will be sorted and displayed according to the Master datatype.

  • 5/26/2018 Eplan Electric p8 Basic 2

    187/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 186/213

    2. In the Project master data list select the master data objects that you wouldlike to transfer to the system master data. (Multiple selection is possible.)

  • 5/26/2018 Eplan Electric p8 Basic 2

    188/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 187/213

    3. Click .

  • 5/26/2018 Eplan Electric p8 Basic 2

    189/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 188/213

    4. In the System master data list select the master data objects that you wouldlike to transfer to the project master data. (Multiple selection is possible.)

  • 5/26/2018 Eplan Electric p8 Basic 2

    190/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 189/213

    5. Click . Click [Close] after you have done with the setting.

  • 5/26/2018 Eplan Electric p8 Basic 2

    191/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 190/213

    Globally synchronize master data

    Utilities > Master data > Synchronize current project

    1. In the Synchronization of master data dialog select[Update] > Project in order to globally replace all outdated project masterdata with newer system master data.

  • 5/26/2018 Eplan Electric p8 Basic 2

    192/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 191/213

    2. Select [Update] > System to globally replace all outdated system master datawith newer project master data.

    3. Click [Close].

  • 5/26/2018 Eplan Electric p8 Basic 2

    193/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 192/213

    16. Numbering Devices

    Numbering Using PLC data

    Options > Settings > Projects > "Project name" > Devices > Number using PLCdata

  • 5/26/2018 Eplan Electric p8 Basic 2

    194/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 193/213

    1. In the dialog Settings: Number using PLC data select a user-defined

    scheme from the drop-down list, or create a new scheme using (New).

    2. In the Settings: Number using PLC data dialog, click (New) above theFormat groups field.

    3. In the Number using PLC data: Format dialog, select the group of devicesfrom the Group drop-down list for which you want to determine the format.

    You can choose between terminals, pins, and devices.

    4. In the Extent drop-down list, select the scope of numbering for the selectedgroup.

    5. In the Available format elements field select a format element and move itover to the right using into the list of selected format elements.

  • 5/26/2018 Eplan Electric p8 Basic 2

    195/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 194/213

    6. Define the formatting in the subsequent dialog.

    7. If desired, you can change the sequence of the formatting elements using thearrow buttons.

    8. Click [OK].

    Numbering Online

    The online numbering format applies to devices that you newly place in theschematic using the menu item Insert > Symbol. It also applies to copied devicesand devices in newly inserted macros.

    You have opened a project.

    Options > Settings > Projects > "Project name" > Devices > Numbering (online)1. In the Settings: Numbering (online) dialog, click [...] next to the Numberingformat field.

  • 5/26/2018 Eplan Electric p8 Basic 2

    196/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 195/213

    2. To create a numbering format click (New) next to the Scheme field.

    3. Enter a descriptive name into the Name field and click [OK].

  • 5/26/2018 Eplan Electric p8 Basic 2

    197/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 196/213

    4. Change to the DT tab.

    5. To allow all devices in the "General DT" device group to be numbered online,select the General DTcheck box.

    6. Click [...] next to the General DT field.

  • 5/26/2018 Eplan Electric p8 Basic 2

    198/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 197/213

    7. In the Available format elements field of the DT format dialog, select the

    "Counter" format element and click (Move right).

    8. In the Format dialog, in the Minimum number of digits field, enter thenumber of positions to be used for the DT counter and click [OK].

    9. Select all of the desired format elements sequentially. Pay attention to therules for the Online numbering format.

    10. Click [OK].

    11. To define the online numbering for all other device groups and connections,proceed in the same manner in the DT and Connection Points tabs.

  • 5/26/2018 Eplan Electric p8 Basic 2

    199/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 198/213

    12. Click (Save) and then click [OK].

  • 5/26/2018 Eplan Electric p8 Basic 2

    200/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 199/213

    Setting Preceding Signs in Displayed DT

    The displayed DT can be displayed with a prefix, e.g. -M1 or without a prefix e.g. M1.Click [OK].

  • 5/26/2018 Eplan Electric p8 Basic 2

    201/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 200/213

    Numbering Devices Online

    When you insert new devices into the schematic then you can define that thesedevices are to be automatically numbered.

    A DT is determined and assigned online for every device that you insert. Thecounter for DT is incremented by one in the process.

    Options > Settings > Projects > "Project name" > Devices > Numbering (online)

  • 5/26/2018 Eplan Electric p8 Basic 2

    202/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 201/213

    Click [OK].

  • 5/26/2018 Eplan Electric p8 Basic 2

    203/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 202/213

    Number online and set flags

    1. In the dialog Settings: Numbering (online) dialog, in the On insertion ofsymbols group box, select the Number with flag "?" option. Click [OK].

  • 5/26/2018 Eplan Electric p8 Basic 2

    204/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 203/213

    Not Numbering Devices OnlineWhen you insert new devices into the schematic then you can define that thesedevices are not to be automatically numbered.

    Options > Settings > Projects > "Project name" > Devices > Numbering (online)

  • 5/26/2018 Eplan Electric p8 Basic 2

    205/211

    EPLAN ELECTRIC P8 Basic Training

    Sysnet Controls Sdn. Bhd. Page 204/213

    Exclude device groups from numberingDevices that are excluded from the numbering are allocated an identifier and acounter. The counter is no