CORROSION - INSULATION THERMAL INSULATION AND CORROSION CONTROLS COATING Superior Products for Superior Results | Copyright © 2012 Superior Products International II | All rights reserved. KEVIN KIM Technical Sales Director 53235, R/No.401, B&B, JaeSan-Ro, 4-2, Geojae-si, KyeongNam, SouthKorea. www.spiinkorea.co.kr [email protected] Superior Products International In KOREA CO.,LTD.

Transcript of Entire SPI KOREA PPT KOREAN 10052019 KOREA...IMO A. 653 (16) -Flame Spread Test for Bulkhead, Wall,...

Page 1: Entire SPI KOREA PPT KOREAN 10052019 KOREA...IMO A. 653 (16) -Flame Spread Test for Bulkhead, Wall, and Ceiling Linings MSC.41 (64) -Toxic Gas Generation, Used Colorimetric Gas Detector

CORROSION - INSULATIONTHERMAL INSULATION AND CORROSION CONTROLS COATING

Superior Products for Superior Results | Copyright © 2012 Superior Products International II | All rights reserved.

KEVIN KIM Technical Sales Director

53235, R/No.401, B&B, JaeSan-Ro, 4-2,

Geojae-si, KyeongNam, SouthKorea.

www.spiinkorea.co.kr

[email protected]

Superior Products International In KOREA CO.,LTD.

Page 2: Entire SPI KOREA PPT KOREAN 10052019 KOREA...IMO A. 653 (16) -Flame Spread Test for Bulkhead, Wall, and Ceiling Linings MSC.41 (64) -Toxic Gas Generation, Used Colorimetric Gas Detector

WHO IS SPI KOREA ?

CORROSION - INSULATION

SPI KOREA

미국 본사설립 1989

본사 : 미국 켄자스 위치 대표 제품

SUPER THERM, HPC, HT, RUST GRIP, ENAMO GRIP

아시아지사 : 경남 거제 NASA 공동 세라믹 공동과제 개발 참여

WHAT DOES SPI DO?

부식방지 페인트 개발공급 단열, 차열 방지 페인트 개발 공급 유지보수 절감 대체 페인트 개발 공급 보온제 하부 부식의 근원이 되는 보온 대체 페인트 개발 공급

Page 3: Entire SPI KOREA PPT KOREAN 10052019 KOREA...IMO A. 653 (16) -Flame Spread Test for Bulkhead, Wall, and Ceiling Linings MSC.41 (64) -Toxic Gas Generation, Used Colorimetric Gas Detector

WHAT DOES SPI DO?

차열,차단 특수 도료 공급태양열(복사,대류,전도)의HEAT CONTROL

부식 방지 특수

CORROSION - INSULATION

내화 특수도료 공급7시간이상 건축자재 보호

부식 방지 특수도료 공급샌드 블라스트없이 원코팅10년-15년 내구성

에너지 절감특수도료 공급20%-60% (평균 40%절감)

CUI 제거 대체 가능특수도료 공급보온제 제거로 CUI(보온제부식)으로 인한 유지보수비 절감

유지보수 비용 절감도료 공급보온제 대체단열제(에너지 효율

Page 4: Entire SPI KOREA PPT KOREAN 10052019 KOREA...IMO A. 653 (16) -Flame Spread Test for Bulkhead, Wall, and Ceiling Linings MSC.41 (64) -Toxic Gas Generation, Used Colorimetric Gas Detector

CORROSION - INSULATIONSPI KOREA PRODUCTS

CORROSION

RUST GRIP®

Moist Metal Grip

Enamo Grip 5000

Lining Kote

Enamo Grip

CORROSION

CONTROL PAINT

SUPER THERM ®

Epoxotherm

Omega Fire™

HEAT BLOCK & FIRE

CONTROL PAINT

INSULATION

CONTROL PAINTOmega Fire™

HPC-HT/HPC®

Epoxotherm

HSC™ Coating

CONTROL PAINT

Page 5: Entire SPI KOREA PPT KOREAN 10052019 KOREA...IMO A. 653 (16) -Flame Spread Test for Bulkhead, Wall, and Ceiling Linings MSC.41 (64) -Toxic Gas Generation, Used Colorimetric Gas Detector

CORROSION - INSULATIONPRODUCTS KEY FEATURES

RUST GRIP ®

3코팅 시스템을 1코팅 시스템으로 대체

작업성 및 경제적 효과 상승 (60%)

경화속도 및 빠른 반응속도로 작업성 상승.

철판 표면 모공으로 침투 후 팽창 및 화학적 반응.

인장강도 및 강도 증가 (6780psi-3주후).

와이트 샌드 블러스트 불 필요.

요구에 따라 하도 및 상도로도 사용 가능.

SUPER THERM ®

높은 차열효과로 에너지 절감.

탱크내 부식유발 될 수 있는 증기 및 결로 방지 .

복사열 흡수 차단으로 표면 온도 상승 차단.

대류로 인한 실내 온도 상승 저하.

공기와 습도의 차단으로 부식 방지 .

최대 70%에너지 절감효과.

Page 6: Entire SPI KOREA PPT KOREAN 10052019 KOREA...IMO A. 653 (16) -Flame Spread Test for Bulkhead, Wall, and Ceiling Linings MSC.41 (64) -Toxic Gas Generation, Used Colorimetric Gas Detector

CORROSION - INSULATION

HPC / HPC-HT

PRODUCTS KEY FEATURES

보온제 및 자케팅 대체 가능 파이프, Heat Exchanger 등 단가 효과 보온제 제거와 같은 업무 불필요.

유지보수 시 셧다운이 필요없음.

상온 650도씨까지 적용 가능.

보온제 적용이 불가한 형태의 적용 가능.

SAVES UP TO 80%

Page 7: Entire SPI KOREA PPT KOREAN 10052019 KOREA...IMO A. 653 (16) -Flame Spread Test for Bulkhead, Wall, and Ceiling Linings MSC.41 (64) -Toxic Gas Generation, Used Colorimetric Gas Detector

HEAT CONTROL COATINGS

단열, 차열 컨트롤 도료제품군 Super Therm®

Epoxotherm Epoxotherm

Omega Fire™

Page 8: Entire SPI KOREA PPT KOREAN 10052019 KOREA...IMO A. 653 (16) -Flame Spread Test for Bulkhead, Wall, and Ceiling Linings MSC.41 (64) -Toxic Gas Generation, Used Colorimetric Gas Detector

★SUPERTHERM® INTRO

HEAT CONTROL COATINGS

수축 & 팽창방지와수압에 대한 내구성

태양빛 96%이상 차단 적외선 및 복사열수압에 대한 내구성

뛰어남

태양빛 96%이상 차단 적외선 및 복사열99.5% , 방사율 91%복사열로인한 실내 대류낮아 AC비용절감 가능

방음 효과 뛰어남50%이상 감소

가연성 테스트 : NASA “A” Class 판정, “0” = BURN 유해가스방출 : 최고등급“K” Class

뛰어나 내곰팡이 기능과월등한 습도 침투 차단

가능 HSC/HPC의 제품으로 내부에전달된 대류, 전도의 상승온도로부터내부 시설의 설비를 더욱 더 보호

Page 9: Entire SPI KOREA PPT KOREAN 10052019 KOREA...IMO A. 653 (16) -Flame Spread Test for Bulkhead, Wall, and Ceiling Linings MSC.41 (64) -Toxic Gas Generation, Used Colorimetric Gas Detector

3 FORMS OF HEAT TRANSFER

HEAT CONTROL COATINGS

에너지 절달의 3가지 타입

3 FORMS OF HEAT TRANSFER

열전도대류

복사열

■ 열관류 율 K (kcal/㎡.h.℃)열관류는 벽과 같은 고체를 통하여 공기층에서공기층으로 열이 전하여 지는 것으로1㎡의 면적을 1℃의 온도차로 단위시간당 흐르는 열량을열관류율이라 합니다.

■ 열전도율 λ (kcal/㎡.h.℃) 열전도는 재료의 앞쪽 표면에서 뒷쪽 표면으로 열이전달하는 것으로 두께 1m, 면적1㎡인 재료의 앞쪽표면에서 뒷쪽 표면으로 1℃의 온도차로 1시간동안전달된 열량을 열전도율이라 합니다.(재료별 열성능비교표 참조)비교표 참조)참조 : 유리의 열전도율은 1.022 (W/m℃), 발포폴리스티렌의 열전도율은 0.033 (W/m℃)

■ 열저항 R (㎡.h.℃/kcal) 고체 내부의 한 지점에서 다른 한 지점까지 열량이통과할 때 이 통과 열량에 대한 저항의 정도를열저항이라 합니다

Page 10: Entire SPI KOREA PPT KOREAN 10052019 KOREA...IMO A. 653 (16) -Flame Spread Test for Bulkhead, Wall, and Ceiling Linings MSC.41 (64) -Toxic Gas Generation, Used Colorimetric Gas Detector

★SUPERTHERM® INTRO

HEAT CONTROL COATINGS

NASA가 개발한 특수한 세라믹 미립자로 수용성의 백색 열차단 코팅재

장비 소음을 차단하여 방음효과 환경 제공 실내 온도 저감으로 임직원의 보다 낳은 실내 휴식 환경 제공 투자 리턴 1.06 년 (13 months).

최대 에너지 절감 : 40% 실내 에너지 절감.

70%이상 대류 이동 감소(코팅표면과 피도물 사이에 공기층을 형성하여 열, 냉기의 이동 차단)

아크릴수지, 우레탄수지와 4종류의 세라믹 화합물 태양빛 95.5%이상 차단 적외선 및 복사열 99.5% , 방사율 91%

Page 11: Entire SPI KOREA PPT KOREAN 10052019 KOREA...IMO A. 653 (16) -Flame Spread Test for Bulkhead, Wall, and Ceiling Linings MSC.41 (64) -Toxic Gas Generation, Used Colorimetric Gas Detector

자외선 차단

★SUPERTHERM® WINDOWS OF RADIATION HEAT

HEAT CONTROL COATINGS

95%이상 차단자외선 (UV) : 99%차단3% of total energy

Responsible for sunburn

가시광선 (VIS) : 92%차단40% of total energy Visible light (Short Wave)

적외선 (IR) : 99.5%차단57% of total energy Felt as heat(Long Wave)

Page 12: Entire SPI KOREA PPT KOREAN 10052019 KOREA...IMO A. 653 (16) -Flame Spread Test for Bulkhead, Wall, and Ceiling Linings MSC.41 (64) -Toxic Gas Generation, Used Colorimetric Gas Detector

NASA Technology Transfer Agreement

★SUPERTHERM® 기술 이전 동의서

HEAT CONTROL COATINGS

NASA Technology Transfer Agreement - Reference # 2617 [1995]

Page 13: Entire SPI KOREA PPT KOREAN 10052019 KOREA...IMO A. 653 (16) -Flame Spread Test for Bulkhead, Wall, and Ceiling Linings MSC.41 (64) -Toxic Gas Generation, Used Colorimetric Gas Detector

단열효과 지붕으로부터 침투 열량 70% - 90% 저감1

HEAT CONTROL COATINGS

★SUPERTHERM® 특징(1)

국제 선급인증 DNV ABS

Super Therm 0.18mm코팅(7mils) = 155mm Fiberglass

태양 복사열 반사 적외선 복사열 반사율(99.5%)1

유연성 ASTM E1737 180 degree bend passed1

내화성(NASA) CLASS “A” , Flame spread “0” , Smoke “0”1

국제 선급인증 노르웨이 (DNV), 미국ABS선급 취득1

IMO 인증 International Marine Organization 인증1

IMO A. 653 (16) - Flame Spread Test for Bulkhead, Wall, and Ceiling LiningsMSC.41 (64) - Toxic Gas Generation, Used Colorimetric Gas Detector Tubes, Met All Toxic Gas Requirements

NASA 불연성, 가연성 테스트 : NHB 8060 1B/ NASA “A” Class 판정, “0” = BURN 유해가스방출 : NHB 8060 1C : 시험결과 최고등급 “K” Class

인장강도 TENSILE TEST : 444psi (3.06 Mpa) 1

인장강도 테스트 : 0.041 Thickness ASTM D412

접착력 PULL OFF TEST : 115.2psi (0.79 Mpa) 1

ADHESION ASTM D4541

Page 14: Entire SPI KOREA PPT KOREAN 10052019 KOREA...IMO A. 653 (16) -Flame Spread Test for Bulkhead, Wall, and Ceiling Linings MSC.41 (64) -Toxic Gas Generation, Used Colorimetric Gas Detector

HEAT CONTROL COATINGS

코팅 내구성 20-25년1

★SUPERTHERM® 특징(2)

방음효과 최대 68% 방음효과 / STC50 1

냉,난방비 절감 K=0.019 w/mk1

UV/SALT SPRAY ASTM 5894(5000hours 통과) 1

일본 소니 40,000m2의 경우 1.06 YEAR (13 months) 투자비 회수.

에너지절감 공무부의 검증 – 특정하우스 지붕 테스트결과 2.2 YEARS 회수 일반적인 에너지 절감 : 40% 절감효과

안전성 USDA 미국 농무성 식품안전위생검사부의 승인 득1

미국 North West 연구소 시험결과 : 염수분무시험등 기타 test 에도 ‘매우 좋음’ 평가 (11년 상당)미국 소비자(K-Teck社) 의견 “도장 시 성능효과를 10년 이후에도 발휘, 개·보수 필요가 없는 도료임

안전성 USDA 미국 농무성 식품안전위생검사부의 승인 득1

식품위생상 전혀 문제가 없어 식품공장, 유제품공장과 축산시설 등의 내벽에도 사용 가능일본 수질분석시험에서도 전혀 무해함 증명“USGBC Gold Certificate”

슬레이드 지붕 수명 연장 노후화된 슬레이드 지붕 강도 회복1

15년 이상 사용한 슬레이드 지붕(허용 하중 270kg)에 Super Therm 시공 시 신제품 준하는 강도(365kg) 회복25년 사용한 슬레이트 지붕(허용 하중 160kg)에 Super Therm 시공 시 강도 295kg로 향상 (84.7%개선)

Page 15: Entire SPI KOREA PPT KOREAN 10052019 KOREA...IMO A. 653 (16) -Flame Spread Test for Bulkhead, Wall, and Ceiling Linings MSC.41 (64) -Toxic Gas Generation, Used Colorimetric Gas Detector

★SUPERTHERM® 특징(3)

HEAT CONTROL COATINGS

실내,외 모두 사용 가능

높은 수압 및 강풍의 내구성 검증

일액형 Water Boned Type

단, 원코팅으로 68%이상의 열전도율 검증

18년이후 도장 솔실율 8% (200DFT)

37 DFT정도만 손실

18년이후 도장 기능저하율 10%이내

ASTM C 1326 테스트검증

60도

47도

57도

42도

ASTM C 1326 테스트검증

Guarded Hot Box test. SUPER THERM®

(두께 250(DFT)

Page 16: Entire SPI KOREA PPT KOREAN 10052019 KOREA...IMO A. 653 (16) -Flame Spread Test for Bulkhead, Wall, and Ceiling Linings MSC.41 (64) -Toxic Gas Generation, Used Colorimetric Gas Detector

Approved and accepted as an

energy star partner for saving energyThe Florida Department of

Environmental Protection is the

state’s

INSULATION CONTROL COATINGS

★SPI CERTIFICATES

ECAP-CUL-1-03 - ENERGY CONSERVATION ASSISTANCE PROGRAM

United States Department of Agriculture

DNV AUDIT

AND DNV COMPLIANT

CRRC(Cool Roof Rating Council)

Leadership in Energy &

Environmental Design

American Bureau of Shipping

National Aeronautics &

Space Administration

American Society for

Testing and Materials

SBCCI (Southern Building Code

Congress International

FACTORY MUTUAL APPROVAL

State of California bureau of

Home Furnishing and Thermal

Insulation

ECAP-CUL-1-03 - ENERGY

CONSERVATION ASSISTANCE

PROGRAM

GOVERNMENT OF

SOUTH AUSTRALIA

AND DNV COMPLIANT

Canadian Food Inspection Agency

ICC consolidates approvals

Environmental Design

International Conference

of Building Officials

MBDC Cradle to Cradle

GOLD CERTIFICATION

China Center for Technical

Testing of Non-Metallic Materials

for Ship Building, China Ship-

Building Corporation.

Page 17: Entire SPI KOREA PPT KOREAN 10052019 KOREA...IMO A. 653 (16) -Flame Spread Test for Bulkhead, Wall, and Ceiling Linings MSC.41 (64) -Toxic Gas Generation, Used Colorimetric Gas Detector

SPI CORROSION CONTROL COATINGS

CERTIFICATIONS AND REGISTRATIONS

테스트 및 인증기관

Page 18: Entire SPI KOREA PPT KOREAN 10052019 KOREA...IMO A. 653 (16) -Flame Spread Test for Bulkhead, Wall, and Ceiling Linings MSC.41 (64) -Toxic Gas Generation, Used Colorimetric Gas Detector

SPI CORROSION CONTROL COATINGS

CERTIFICATIONS AND REGISTRATIONS

테스트 및 인증기관

Page 19: Entire SPI KOREA PPT KOREAN 10052019 KOREA...IMO A. 653 (16) -Flame Spread Test for Bulkhead, Wall, and Ceiling Linings MSC.41 (64) -Toxic Gas Generation, Used Colorimetric Gas Detector

SPI CORROSION CONTROL COATINGS

★SUPERTHERM® 테스트인증

No. 비고 인증항목 시험결과

1 수증기 통과 E 96 합격(0.01 미만)

2 내 균열성(금속, 고무 표면에서) D 522합격

(25mm, 6mm bend)

3 인장강도 D 412합격(1mm 두께에서

931 kg/cm2

4 Section(723.2 / 723.3) BOCA 합격

5 Flame Spread E 84 89

합격

6 Smoke Spread "0"6 Smoke Spread "0"

7 열전도성 C 177 합격

8 내열, 열전도성 C 411 합격

9 염수분무 D 1654 합격(2,000시간)

10 곰팡이 번식/ 오염물 축적 D 3274 Excellent

11코팅필름의 태양빛 반사율

JIS A575995%

코팅필름의 적외선 반사율 99.5%

Page 20: Entire SPI KOREA PPT KOREAN 10052019 KOREA...IMO A. 653 (16) -Flame Spread Test for Bulkhead, Wall, and Ceiling Linings MSC.41 (64) -Toxic Gas Generation, Used Colorimetric Gas Detector

SPI CORROSION CONTROL COATINGS

★SUPERTHERM® ASTM TESTING

**별첨자료 참조

Page 21: Entire SPI KOREA PPT KOREAN 10052019 KOREA...IMO A. 653 (16) -Flame Spread Test for Bulkhead, Wall, and Ceiling Linings MSC.41 (64) -Toxic Gas Generation, Used Colorimetric Gas Detector

APPLICATION INSTRUCTION

SURFACE PREPARATION 표면처리 TSP (tri-sodium-phosphate), 또는 시트러스로 표면 클린링

HEAT CONTROL COATINGS

표면처리 TSP (tri-sodium-phosphate), 또는 시트러스로 표면 클린링 WATER JETTING(NACE No.6 / sspc-sp12) @ 3500 psi

도포전 표면의 건조상태이어야 한다.

NITRATES LEVEL 5-10 mcg/cm2, Sulfatees : 5-10mcg/cm2, chlorides : 3-

5mcg/cm2

기존 도장의 표면 도포시 glossed or shiny의 표면은 샌딩작업으로기본적인 프로파일을 생성하고 도포하여야만 한다.

POT LIFE 4-7hr at 70°F (21°C) at 60%(RH)

HARD CURE TIME Tack-free - 30-60 minutes to : (21°C) at 40% RH Tack-free - 30-60 minutes to : (21°C) at 40% RH

Overcoat : 2시간 (21°C) at 40% RH

Fully cures – in 21days : (21°C) at 40% RH

APPLICATION (1.5 gallons/minute at 3,300 psi) : TIP- 0.029 - 0.033 tip

Page 22: Entire SPI KOREA PPT KOREAN 10052019 KOREA...IMO A. 653 (16) -Flame Spread Test for Bulkhead, Wall, and Ceiling Linings MSC.41 (64) -Toxic Gas Generation, Used Colorimetric Gas Detector

TECHNICAL DATA

PHYSICAL DATA

HEAT CONTROL COATINGS

DESCRIPTION일핵형 타입Water-Borne Combination

TYPICAL USEROOF

HVAC SYSTEMS

TANKS

SPHRES

STORAGE SYSTEMS

PHYSICAL DATAVOLUME SOLIDS : By weight 66% / By volume 61% TO TACK FREE : 30-60분(21°C) OVERCOAT WINDOW : 2 hr or less at 70°F (21°C) LEAD AND CHROMATE FREE Cures by evaporationNET WEIGHT : 11.88 lbs. per gallon

VEHICLE TYPE : Urethane / Acrylic Blend MOISTURE-CURE POLYURETHANE SHELF LIFE : Up to 5 years ONE COMPONENT COATING ; No curing agent needed VOC LEVEL : 21 grams/liter

VISCOSITY : 105 – 110KUSTORAGE SYSTEMS

APPLICATION METHODS16Mils wet(400microns)

9Mils dry(225microns)

VISCOSITY : 105 – 110KU

PH : 8.5-9.0

TEMPERATUREMaximum Surface Temperature when applying; 150°F (65°C)

Minimum Surface Temperature when applying; 50°F (5°C)

Maximum Surface Temperature after curing; 325°F (149°C)

Page 23: Entire SPI KOREA PPT KOREAN 10052019 KOREA...IMO A. 653 (16) -Flame Spread Test for Bulkhead, Wall, and Ceiling Linings MSC.41 (64) -Toxic Gas Generation, Used Colorimetric Gas Detector

★SUPERTHERM® 에너지 절감 효과(1)

HEAT CONTROL COATINGS

MITSUBISHI -기와 지붕 3,200m2MITSUBISHI -기와 지붕 3,200m2

Page 24: Entire SPI KOREA PPT KOREAN 10052019 KOREA...IMO A. 653 (16) -Flame Spread Test for Bulkhead, Wall, and Ceiling Linings MSC.41 (64) -Toxic Gas Generation, Used Colorimetric Gas Detector

HEAT CONTROL COATINGS

도시바 EMI 고텐바공장 -기와 지붕 6,000m2

★SUPERTHERM® 에너지 절감 효과(2)

도시바 EMI 고텐바공장 -기와 지붕 6,000m2

투자 회수 3.6년

★ ★★ ★

Page 25: Entire SPI KOREA PPT KOREAN 10052019 KOREA...IMO A. 653 (16) -Flame Spread Test for Bulkhead, Wall, and Ceiling Linings MSC.41 (64) -Toxic Gas Generation, Used Colorimetric Gas Detector

HEAT CONTROL COATINGS

★SUPERTHERM® 에너지 절감 효과(3)

일본시공업체 이후 에너지 절감 효과일본시공업체 이후 에너지 절감 효과

Page 26: Entire SPI KOREA PPT KOREAN 10052019 KOREA...IMO A. 653 (16) -Flame Spread Test for Bulkhead, Wall, and Ceiling Linings MSC.41 (64) -Toxic Gas Generation, Used Colorimetric Gas Detector

기존 보온제 SUPER THERM®

★SUPERTHERM® vs Fiberglass

HEAT CONTROL COATINGS

기존 보온제 SUPER THERM®

열전도만 고려됨 열전도, 대류, 복사열 고려됨

100% 열 흡수후, 빠른 열전달 사전 열흡수 전 95%차단

수명에 따른 노화 빠름 장기 수명 고려

섭시 75도에서 테스트 필드 테스트를 통한 검증섭시 75도에서 테스트 필드 테스트를 통한 검증

설치에 따른 두께 손실 큼 두께 225 micron DFT

습도, 에어에 따른 영향 큼 습도, 에어등으로부터 완전 차단

Page 27: Entire SPI KOREA PPT KOREAN 10052019 KOREA...IMO A. 653 (16) -Flame Spread Test for Bulkhead, Wall, and Ceiling Linings MSC.41 (64) -Toxic Gas Generation, Used Colorimetric Gas Detector

The load

★SUPERTHERM® SYSTEMS DOE TESTED Table # 1

FLORIDA RESSIDENTUAL HOUSING

HEAT CONTROL COATINGS

The load producing

components tested are as follows;

TYPE OF SYSTEM

BTUPER SQUARE FOOT PER

HOUR

SOLAR GAIN

INSIDE SURFACE

TEMPERATURERECORDED

APPROXIMATE

R-VALUEAPPROXIMATE

U-VALUE

TOTALBTU / THERMAL

LOAD

&UV ABSORBTON

STANDARDROOF

206 145 Max. 22.0 0.045206 / 145

98.0

CERAMIC COATING

ROOF85 118 Max.

19.0Reflectance Equivalent

0.27085 / 118

03.0

System loads as testedTotal roof load with no retrofit 226,600 btu’s \ hour.Retrofitted roof load 93,500 btu’s \ hour.Savings from retrofit 133,100 btu’s \per hour.Reduced enviromental impact 66 pounds of power plant emmisions / hr.

Page 28: Entire SPI KOREA PPT KOREAN 10052019 KOREA...IMO A. 653 (16) -Flame Spread Test for Bulkhead, Wall, and Ceiling Linings MSC.41 (64) -Toxic Gas Generation, Used Colorimetric Gas Detector

★SUPERTHERM® GCC TESTING

HEAT CONTROL COATINGS

Page 29: Entire SPI KOREA PPT KOREAN 10052019 KOREA...IMO A. 653 (16) -Flame Spread Test for Bulkhead, Wall, and Ceiling Linings MSC.41 (64) -Toxic Gas Generation, Used Colorimetric Gas Detector

★SUPERTHERM® GCC TESTING

HEAT CONTROL COATINGS

Page 30: Entire SPI KOREA PPT KOREAN 10052019 KOREA...IMO A. 653 (16) -Flame Spread Test for Bulkhead, Wall, and Ceiling Linings MSC.41 (64) -Toxic Gas Generation, Used Colorimetric Gas Detector

★SUPERTHERM® TESTING (1)

FLORIDA DOE OFFICE TESTING

HEAT CONTROL COATINGS

U.S. DEPARTMENT OF ENERGY

• 에너지 흡수에서 46 to 52% 차이• 실내온도 22F 더 낮은온도 확인• 외부온도 47F 더 낮은온도 확인• 내부 습도율 28.5% 더 드라이 확인

Page 31: Entire SPI KOREA PPT KOREAN 10052019 KOREA...IMO A. 653 (16) -Flame Spread Test for Bulkhead, Wall, and Ceiling Linings MSC.41 (64) -Toxic Gas Generation, Used Colorimetric Gas Detector

FLORIDA DOE OFFICE TESTING

HEAT CONTROL COATINGS

★SUPERTHERM® TESTING (2)

U.S. DEPARTMENT OF ENERGY

백색페인트 vs Super Therm®

• 80 BTU/SF/HR – Super Therm®

• 235 BTU/SF/HR – 백색페인트• 두 시험 보온제 적용은

R-13 Insulation으로 적용• 26%-30% 에너지 절감효과 확인

FIBERGLASS vs Super Therm®

Fiberglass : 3” rated 0.53 BTU K value.

SUPER THERM

단면 : 10 DFT(0.31 BTU K value)

양면 : 10 DFT(0.21 BTU K value)

148% BETTER PERFORMANCE

Page 32: Entire SPI KOREA PPT KOREAN 10052019 KOREA...IMO A. 653 (16) -Flame Spread Test for Bulkhead, Wall, and Ceiling Linings MSC.41 (64) -Toxic Gas Generation, Used Colorimetric Gas Detector

SAUDI ARAMCO OIL

HEAT CONTROL COATINGS

★SUPERTHERM® TESTING (3)

SUPER THERM - NG Tank Spheroid 203A Existing Tank – NG Tank Spheroid 203B

SAUDI ARAMCO OIL

TANK FIELDNovember 2013

외부온도

35.1 - 50.9 차이

Page 33: Entire SPI KOREA PPT KOREAN 10052019 KOREA...IMO A. 653 (16) -Flame Spread Test for Bulkhead, Wall, and Ceiling Linings MSC.41 (64) -Toxic Gas Generation, Used Colorimetric Gas Detector

Mitsubishi Related Tank TerminalDaiko Shakai Co., LTD STORAGE TANKS

HEAT CONTROL COATINGS

★SUPERTHERM® PROJECTS

• HOKKO TERMINAL 39 탱크 SUPERTHERM 시공

• 쿨링워터와 추가 전력 절감 효과

• VOC(유해방출율) 저하로 친환경 효과

• 14년간 문제없이 필드 검증

• Mitsubishi 친환경적 차원에서 더욱더 확대 사용적용.

Daiko Shakai Co., LTD

Osaka, Japan

STORAGE TANKS

적용.

Page 34: Entire SPI KOREA PPT KOREAN 10052019 KOREA...IMO A. 653 (16) -Flame Spread Test for Bulkhead, Wall, and Ceiling Linings MSC.41 (64) -Toxic Gas Generation, Used Colorimetric Gas Detector

• 문제점 : 두바이 호텔의 사막 고온으로 AC의과부하 문제와 banquet hall의 온도 상승으로

THE ADDRESS MARINA HOTEL

* RESORTS IN DUBAI

HEAT CONTROL COATINGS

★SUPERTHERM® PROJECTS

과부하 문제와 banquet hall의 온도 상승으로적용 시행

• 해결 : 지붕 및 해당구역 적용@ 250 micron DFT.

• 결과 : 12C 가량 실내 온도 하락(Sept 29th ,2012)

56도 - 43.6도 감소(2년뒤 재측정)

* RESORTS IN DUBAI

Page 35: Entire SPI KOREA PPT KOREAN 10052019 KOREA...IMO A. 653 (16) -Flame Spread Test for Bulkhead, Wall, and Ceiling Linings MSC.41 (64) -Toxic Gas Generation, Used Colorimetric Gas Detector

ROOFING APPLICATION • Slate Roof Insulation Coating Project

HEAT CONTROL COATINGS

★SUPERTHERM® PROJECTS

ROOFING APPLICATION

Nissan Motor Co., LTD

• Slate Roof Insulation Coating Project

• 적용구간– 165,000 m2

Before Cool Therm Application After Cool Therm Application

Page 36: Entire SPI KOREA PPT KOREAN 10052019 KOREA...IMO A. 653 (16) -Flame Spread Test for Bulkhead, Wall, and Ceiling Linings MSC.41 (64) -Toxic Gas Generation, Used Colorimetric Gas Detector

ROOFING APPLICATION • 22% 의 에너지 감소 효율

HEAT CONTROL COATINGS

★SUPERTHERM® PROJECTS

ROOFING APPLICATIONTucson International Airport

Arizona, U.S.

• 22% 의 에너지 감소 효율• +40% HVAC Savings

Before Cool Therm Application After Cool Therm Application

Page 37: Entire SPI KOREA PPT KOREAN 10052019 KOREA...IMO A. 653 (16) -Flame Spread Test for Bulkhead, Wall, and Ceiling Linings MSC.41 (64) -Toxic Gas Generation, Used Colorimetric Gas Detector

SURFACE APPLICATION

HEAT CONTROL COATINGS

★SUPERTHERM® PROJECTS

• 30% 의 에너지 감소 효율SURFACE APPLICATIONSTORAGE TANKS

• 30% 의 에너지 감소 효율

Page 38: Entire SPI KOREA PPT KOREAN 10052019 KOREA...IMO A. 653 (16) -Flame Spread Test for Bulkhead, Wall, and Ceiling Linings MSC.41 (64) -Toxic Gas Generation, Used Colorimetric Gas Detector

BLUE CHIP VESSELMISSISSIPPI, U.S.

ROWAN DRILLING NORTH SEA, U.K.

HEAT CONTROL COATINGS

★SUPERTHERM® PROJECTS

MISSISSIPPI, U.S. NORTH SEA, U.K.

• ABS Class Vessel

• Reduced Heat Load

• Reduced Expansion and Contraction

• Stopped Condensation표면온도 124도 89도

Cecil Provine Offshore Oil Rig

Super Therm® was applied to the Control Room roof on the Cecil Provine

and dropped the surface temperature by 35º (124ºF to 89ºF).

Page 39: Entire SPI KOREA PPT KOREAN 10052019 KOREA...IMO A. 653 (16) -Flame Spread Test for Bulkhead, Wall, and Ceiling Linings MSC.41 (64) -Toxic Gas Generation, Used Colorimetric Gas Detector

★RUST GRIP® PROJECT

SPI CORROSION CONTROL COATINGS

★RUST GRIP® PROJECT

SPI CORROSION CONTROL COATINGS

SUNOCO CHEMICAL OIL TANKS KENOVA, WVNeal Plant in Kenova, West Virginia Neal Plant in Kenova, West Virginia

탱크규격

coated with Rust Grip® and Super Therm®

탱크규격Volume – 30,000 gals.

Length – 75.20 ft.

Outside Diameter – 9.13 ft.

Surface Area – 2,156 sq.ft.

Saddle Surface Area – 100 sq.ft.

Total Surface Area – 2,256 sq.ft.

탱크 내부 온도저하 목적과 부식 방청억제를 위한 작업

Page 40: Entire SPI KOREA PPT KOREAN 10052019 KOREA...IMO A. 653 (16) -Flame Spread Test for Bulkhead, Wall, and Ceiling Linings MSC.41 (64) -Toxic Gas Generation, Used Colorimetric Gas Detector

U.S. RESIDENTIAL NEIGHBORHOOD

Arizona, U.S.COMMERCIAL HVAC

HEAT CONTROL COATINGS

★SUPERTHERM® PROJECTS

Arizona, U.S.

• Moisture barrier

• Sound dampening

• Replaces external paint

• Available in multiple colors

COMMERCIAL HVAC

Page 41: Entire SPI KOREA PPT KOREAN 10052019 KOREA...IMO A. 653 (16) -Flame Spread Test for Bulkhead, Wall, and Ceiling Linings MSC.41 (64) -Toxic Gas Generation, Used Colorimetric Gas Detector

★SUPERTHERM® PROJECTS

HEAT CONTROL COATINGS

TRUCKING REPORTDANVER

적용이후 144F--57F 감소 효과

DANVER

Page 42: Entire SPI KOREA PPT KOREAN 10052019 KOREA...IMO A. 653 (16) -Flame Spread Test for Bulkhead, Wall, and Ceiling Linings MSC.41 (64) -Toxic Gas Generation, Used Colorimetric Gas Detector

INSULATION CONTROL COATINGS

★SPI CLIENTS

TOP COMPANIES USING TOP COMPANIES USING

Rust Grip®

• Mitsubishi

• Nissan

• Panasonic

• General Dynamics

• Hoover Dam

• HEB Grocery Company

• Trucking - Refrigeration

Trailers

• Major Oil Firms - Worldwide

• Halliburton Company

• Drydocks World • Drydocks World

• Vodafone Group PLC

• Home Builders

• U.S. Army

• U.S. Air Force

• U.S. Navy

Page 43: Entire SPI KOREA PPT KOREAN 10052019 KOREA...IMO A. 653 (16) -Flame Spread Test for Bulkhead, Wall, and Ceiling Linings MSC.41 (64) -Toxic Gas Generation, Used Colorimetric Gas Detector

CORROSION - INSULATION

SUPERIOR PRODUCTS INTERNATIONAL IN KOREA CO.,LTD.

KEVIN(KILJAE) KIM Technical Sales Director

53235, R/No.401, B&B, JaeSan-Ro, 4-2,Geojae-si, KyeongNam, SouthKorea.

Office : +82 55 633 9992 / Fax : +82 55 633 6821

Mobile: +82(0)10 6327 2323 / Kakao ID : codiline80 Mobile: +82(0)10 6327 2323 / Kakao ID : codiline80

Email : [email protected] / [email protected]

Website : www.spiinkorea.com

Genuine SPI COATING PRODUCTS can only be purchased from SPI Authorized Representatives displaying

the SPI Authorized Logo.

The Right Coating for Ultimate Protection™

Copyright © 2012 – Superior Products International II, Inc. All rights reserved.