Datasheet
YCS-230V Cabin Control Unit
DS_YCS-230V_2.0.doc Page 1 of 4 01.08.2012
Index
1 Cabin Control Unit functions......................................................................................................................... 1
2 Technical specifications: .............................................................................................................................. 1
3 Available YCS-230 models ........................................................................................................................... 2
4 Mounting dimensions .................................................................................................................................. 3
5 Mounting suggestion ................................................................................................................................... 4
6 DALI interface ............................................................................................................................................ 4
1 Cabin Control Unit functions
Light dimmer outputs.(Dual Dimmer version: 5 Dimmers) Relay outputs. (Non dimmable On/Off switching for lights or auxiliary 230V equipment) Heater / Fan coil supply / Dual Dimmer: (Dual heater supply or A/C fan and valve control or 2 dimmers.) Room temperature sensor. 5 control button inputs. Lantic Link (Interface to Lantic LCD Touch panel control) DALI Link (optional) 115VAC configuration optional
2 Technical specifications:
Dimmer outputs: - 3 Dimmer outputs (Short-circuit protected) (6way TB) Max 3x400W @ 230Vac
Max 3x300W @ 115Vac Relay outputs: - 2 Relay Outputs (4way TB) Max 4A each Light On/Off: - 5 Contact inputs to control dimmers and relays (10pins of 12way TB) Room Temperature sensor: - Input for room temperature sensor (2pins of 12way TB) Heater outputs (YCS-230H version only): - 2 Outputs for controlling heater (4way TB) Max: 6A 110-250Vac
Datasheet
YCS-230V Cabin Control Unit
DS_YCS-230V_2.0.doc Page 2 of 4 01.08.2012
Fan Coil Output (YCS-230F version only): - 1 A/C Fan output and 1 Valve output (4way TB) Max: 6A 110-250Vac Dimmer outputs: - 2 Dimmer outputs (Short-circuit protected) (4way TB) Max 2x400W @ 230Vac
Max 2x300W @ 115Vac Network: - Lantic Link (for interconnecting LCD touch panels, YCS server, CCS relays other YCS-230s) (4way TB) RS-485 - Optional DALI link (for controlling DALI compatible devices) (2way TB) Power Inputs: - Separate power inputs for Dimmers, Relays and Heater/Fan Coil (3 x 2way TB) Maximum ambient temperature: <40 C/104F
Standby power consumption with one LCD panel: ~15W. Maximum power consumption @115VAC (full load on all outputs): ~3200W. (3 supply feeds) Maximum power consumption @230VAC (full load on all outputs): ~5800W. (3 supply feeds) Mains supply: Internal selection between 115VAC & 230VAC. Maximum heat generation: ~50W. Net Weight: model YCS-230H+YCS230F+YCS230-D5: 2.6 kg.
3 Available YCS-230 models
Lantic Order No: Product Description 1512 YCS-230 (3 dimmers only) 1513 YCS-230-Heater 1514 YCS-230-Fancoil 1517 YCS-230-D5 (Dual dimmer) All Systems must be accessible for maintenance Front View:
Datasheet
YCS-230V Cabin Control Unit
DS_YCS-230V_2.0.doc Page 3 of 4 01.08.2012
Bottom View:
Top View:
4 Mounting dimensions
Datasheet
YCS-230V Cabin Control Unit
DS_YCS-230V_2.0.doc Page 4 of 4 01.08.2012
5 Mounting suggestion
6 DALI interface
The Dali Link is a two wire interface for third party dimmer modules. The Dali Link is located on PL15 on the YCS unit. It is mandatory that an external +24V power supply is connected as displayed in below example.