Doc Duis In1

download Doc Duis In1

of 16

Transcript of Doc Duis In1

  • 8/18/2019 Doc Duis In1

    1/16

    w w w . d u i s a . c o m

    E m e r g e n c y l i g h t i n g

  • 8/18/2019 Doc Duis In1

    2/16

    Duisa was founded in 1999focusing its activities on thedevelopment of new products inthe emergency lighting andsignalling sector.

    Duisa focussies on theinnovation and quality and thishas allowed it to contribute to

    the creation of competitivetechnical solutions for a moreand more demanding market, likethe emergency lighting whichinvolves people’s safety.

    From the beginning, Duisa hasbeen principally characterized byits vocation for exporting,providing the necessary meansto the adaptation to the newneeds and demands of themarket. At the moment itoperates in different countries allaround the world.

  • 8/18/2019 Doc Duis In1

    3/16

    Product developmentcharacterized by theaccomplishment of thefollowing requirements:

    Installation costs and electricity

    consumption savings: use of cooltechnology.

    Quick-fix connection systememploying a base plate for easyinstallation.

    Charging system based on low-heatcapacitive impedance whichincreases the power of the installation,saving electricity costs.

    Durability, long life:

    manufactured with first-class

    materials

    “Polycarbonate” plastic material which

    complies with the European normativeEN-60598-2-22 relating to the glowwire test 850º

    Top brand f luorescent lampsguaranteeing a long life.

    High temperature Ni-CD rechargeablebatteries.

    Mains present / Battery charging LEDindicators.

     Aesthetic image: Wide range of

    models with various fitting

    options

    Surface, Recessed and Flushmounted in walls and ceilings.

    Various finishing trimsSealed protection for Series eco-ES.

    Compact dimensiones adapting toany environment

    Environmentally friendly:

    Developed and manufactured

    following the EcoDesign criteria

    Halogen free printed circuits.

    Low-weight due to absence of inputtransformer.

    Less consumption and automaticpower factor correction due to its“cool technology”

    1

  • 8/18/2019 Doc Duis In1

    4/16

    245

            8        2

    56

    50

    100

    150

    200

    250

    -0º-20º 20º

    -40º 40º

    -60º 60º

    -80º 80º

    PL 9W

    Vertical cut-offHorizontal cut-off

    cd/Klm

    50

    100

    150

    200

    250-20º 20º

    -40º 40º

    -60º 60º

    -80º 80º

    -0º

    Photometric curves

    FL 6W

    Vertical cut-offHorizontal cut-off

    cd/Klm

    (1) See reference D-eco Series

    D-eco (1)

     All models come with On/Off pushbuttons as standard.Should you require remote control then please add a “T” to the endof the reference code.

    D-eco 40

    D-eco 70

    D-eco 100

    D-eco 160D-eco 240

    D-eco 300

    D-eco 350

    D-eco 90 - 2

    D-eco 60 - 3

    Reference Lumens

    40

    70

    100

    160220

    300

    360

    100

    70

    Lamp

    FL 6 W

    FL 6 W

    FL 6 W

    FL 6 WFL 6 W

    PL 9 W

    PL 9 W

    FL 6 W

    FL 6 W

     Autonomy

    1 h.

    1 h.

    1 h.

    1 h.1 h.

    1 h.

    1 h.

    2 h.

    3 h.

    Per Pack 

    20 units

    20 units

    20 units

    20 units20 units

    20 units

    20 units

    20 units

    20 units

    DescriptionReference

    Remote control

    Emergency sign (1) (2)

    50 TE

    EC...(1) See references D-eco on page 12

    (2) Special signs available on request.

     Accesories

    Colour

    Grey

    Green

    D-eco Series

    surface

    D-eco2

  • 8/18/2019 Doc Duis In1

    5/16

  • 8/18/2019 Doc Duis In1

    6/16

    flush in ceiling

    Hole required:

    258 mm. x 88 mm.

    269

            1        0        6

    258

            2

    88

    269

            1        0        6

    2

    70

    flush in wall

    D-eco (1) + AETB D-eco

    (1) See reference D-eco Series on page 2

    (1) See reference D-eco Series on page 2

    D-eco (1) + AEPB D-eco

    50

    100

    150

    200

    250

    -0º-20º 20º

    -40º 40º

    -60º 60º

    -80º 80º

    PL 9W

    Vertical cut-offHorizontal cut-off

    cd/Klm

    50

    100

    150

    200

    250-20º 20º

    -40º 40º

    -60º 60º

    -80º 80º

    -0º

    Photometric curves

    FL 6W

    Vertical cut-offHorizontal cut-off

    cd/Klm

    DescriptionReference

    Remote control

    Wall flush mounting accesory.Wall flush mounting accesory.

    Ceiling flush mounting accesory.Ceiling flush mounting accesory.

    Emergency sign (1) (2)

    50 TE

    AEPB D-ecoAEPGP D-eco

    AETB D-ecoAETGP D-eco

    EC...

     Accesories

    Colour

    Grey

    WhiteSilver grey (RAL9006)

    WhiteSilver grey (RAL9006)

    Green

    (1) See references D-eco on page 12

    (2) Special signs available on request.

    D-eco Series

    D-eco4

  • 8/18/2019 Doc Duis In1

    7/16

  • 8/18/2019 Doc Duis In1

    8/16

     All models come wi th On/Off pushbuttons as standard.Should you require remote control then please add a “T” to the endof the reference code.

    eco 40

    eco 70

    eco 100

    eco 160

    eco 240

    eco 300

    eco 350eco 90 - 2

    eco 60 - 3

    Reference Lumens

    40

    70

    100

    160

    220

    300

    360

    100

    70

    Lamp

    FL 6 W

    FL 6 W

    FL 6 W

    FL 6 W

    FL 6 W

    PL 9 W

    PL 9 W

    FL 6 W

    FL 6 W

     Autonomy

    1 h.

    1 h.

    1 h.

    1 h.

    1 h.

    1 h.

    1 h.

    2 h.

    3 h.

    Per Pack 

    20 units

    20 units

    20 units

    20 units

    20 units

    20 units

    20 units

    20 units

    20 units

    245

    54

            8        2

    Photometric curves

    40

    80

    120

    160

    200

    0º20º

    40º

    -20º

    -40º

    60º

    80º

    -60º

    -80º

    Vertical cut-offHorizontal cut-off

    cd/Klm

    280

    240

    FL 6W

    PL 9W

    40

    80

    120

    160

    200

    20º

    40º

    -20º

    -40º

    60º

    80º

    -60º

    -80º

    Vertical cut-offHorizontal cut-off

    cd/Klm

    280

    240

    (1) See reference eco Series

    DescriptionReference

    Remote control

    Emergency sign (1) (2)

    50 TE

    EC...

     Accessories

    Colour

    Grey

    Green

    surface

    eco  (1)

    (1) See references eco  on page 12

    (2) Special signs available on request.

    eco Series

    eco6

  • 8/18/2019 Doc Duis In1

    9/16

  • 8/18/2019 Doc Duis In1

    10/16

    recessed in wall

    recessed in ceiling

    eco Series

    (1) See reference eco  Series on page 6

    eco  (1) + ATB eco + eco DBC

    (1) See references eco  Series on page 6

    eco  (1)+ APB eco

    (1) See reference eco  Series on page 6

    eco  (1)+ ATB eco

    Reference

    Remote control

    Emergency sign (1) (2)

    Double sided diffuser

    Ceiling recessing accessory

    Description

    50 TE

    EC...

    eco DBC

    ATB ecoATC ecoATN ecoATO eco

    APB ecoAPC ecoAPN ecoAPO eco

    Wall recessing accessory

    Grey

    Green

    Opal

    WhiteChromeNickelGold

    Colour

    WhiteChromeNickelGold

     Accesories

    (1) See references eco  on page 12

    (2) Special signs available on request.

    eco 8

  • 8/18/2019 Doc Duis In1

    11/16

  • 8/18/2019 Doc Duis In1

    12/16

    sealed

    sealed recessed

    Photometric curves

    40

    80

    120

    160

    200

    0º20º

    40º

    -20º

    -40º

    60º

    80º

    -60º

    -80º

    Vertical cut-offHorizontal cut-off

    cd/Klm

    280

    240

    FL 6W

    PL 9W

    40

    80

    120

    160

    200

    20º

    40º

    -20º

    -40º

    60º

    80º

    -60º

    -80º

    Vertical cut-offHorizontal cut-off

    cd/Klm

    280

    240

    (1) See reference eco-ES Series

    eco-ES (1)

    (1) See reference eco-ES Series

    eco-ES (1) + APES eco

    Reference Description

    50 TE

    APES eco

    EC...

    Remote control

    Wall recessing accessory

    Emergency sign (1) (2)

    Colour

    Grey

    Inox

    Green

     All models come with On/Off pushbuttons as standard.Should you require remote control then please add a “T” to the endof the reference code.

    eco-ES 40

    eco-ES 70

    eco-ES 100

    eco-ES 160

    eco-ES 240eco-ES 300

    eco-ES 350

    eco-ES 90 - 2

    eco-ES 60 - 3

    Reference Lumens

    40

    70

    100

    160

    220300

    360

    100

    70

    Lamp

    FL 6 W

    FL 6 W

    FL 6 W

    FL 6 W

    FL 6 WPL 9 W

    PL 9 W

    FL 6 W

    FL 6 W

     Autonomy

    1 h.

    1 h.

    1 h.

    1 h.

    1 h.1 h.

    1 h.

    2 h.

    3 h.

    Per Pack 

    12 units

    12 units

    12 units

    12 units

    12 units12 units

    12 units

    12 units

    12 units

     Accesories

    (1) See references eco on page 12

    (2) Special signs available on request.

    eco-ES Series

    eco

    10

  • 8/18/2019 Doc Duis In1

    13/16

  • 8/18/2019 Doc Duis In1

    14/16

    Technical characteristics

    • Feed voltage: 230V-50 Hz or110/120V-60 Hz.

    • Autonomous, with non-permanentstand-by.

    • Protection level for Series D-eco andeco: IP 22 IK 04. Class II

    • Suitable for direct mounting onnormally flammable surfaces. F

    • Rechargeable high-temperature NiCdsealed accumulators.

    • Battery charge time: 24 hours.• Deep discharge battery protection.• Overcurrent protection.• Switches over to emergency when

    the mains supply drops to 70% of itsnominal value.

    • Mains present / Battery Chargingindicators using bright, long-life LEDs(approx. 100.000 hours).

    • Front panel On/Off pushbuttons asstandard.

    • Remote control option. Suitable to be

    placed in a DIN 46277/3 rail,EN 50022 of an electric panel. Itswidth is equivalent to 4 standardmagnetothermal switches.

    • Simulated mains failure test.• Surface, Recessed and Flush

    mounted in walls and ceilings.• Sealed Eco protection for the Series

    eco-ES.Protection level: IP 65 IK 07. Surfaceand recessed mounted in wall

    • Quick-fix connection system on allmodels employing a base plate for aneasy installation.

    • Four possible power inlets, three sideones for tubes and one rear one.

    • Terminals for connecting wires of up

    to 2 x 2,5 mm2 per pole.• Quick-fit, screw-free recessing boxes.

    Emergency sign

    Complies with standards

    EN 60598-2-22EN 55015EN 61000-3-2EN 61547

    Complies with Low Voltage 2006/95/EC,Electromagnetic Compatibility2004/108/EC and RoHS 2002/95/ECDirectives.

    D-eco: Ref.: EC0112

    eco: Ref .: EC0012

    D-eco: Ref.: EC0113

    eco: Ref .: EC0013

    D-eco: Ref.: EC0129

    eco: Ref .: EC0029

    D-eco: Ref.: EC0124

    eco: Ref .: EC0024

    EXIT

    D-eco: Ref.: EC0115

    eco: Ref .: EC0015

    D-eco: Ref.: EC0116

    eco: Ref .: EC0016

    D-eco: Ref.: EC0117

    eco: Ref .: EC0017

    D-eco: Ref.: EC0110

    eco: Ref .: EC0010

    SALIDAD-eco: Ref.: EC0114

    eco: Ref .: EC0014

    12

  • 8/18/2019 Doc Duis In1

    15/16

  • 8/18/2019 Doc Duis In1

    16/16

    www.duisa.com • e-mail:[email protected]

    Duisa, S.A. reserves the right to make alterations to the specifications without prior notification. Edition 1 - Revision 0. 25-02-08

    E m e r g e n c y l i g h t i n g

    DUISA, S.A. c/Ibarredi, 6 - Pol. Ind. Júndiz - Apdo. 5.008 - 01015 VITORIA (Spain)

    Tel.: 0034 945 29 21 40 • Fax: 034 945 29 03 57