SAVES ENERGY UPTO 60% !ENERGY SAVERENERGY SAVER COOL ARTS-SB
DIGITAL “ADCA”
Payback period - 30 to 45 days
Savings Verified & Monitored by In-built Hour Meters
Completely Automatic Operation
Digital Display of Actual Water Temperature
Independently Settable Motor ON/Motor OFF / Hooter Temp.
Built-in 2 level Water Level Controller
DIN Standard ABS case in Sturdy Wall Mounting Metal Body
4~20mA Output
Safety Time Interlock to avoid frequent Start/Stops
-
Product improvement is a continuous process at Data given in this publication is, therefore, subject to revision.Cogent Controls
ABOUT ADCA
PRINCIPLE OF "ADCA" OPERATION
WHO CAN USE ‘ADCA’?
HOW THE SAVINGS ARE AFFECTED?
ADCA, a sensor based controller that Automatically switches the FAN motor situated on the top of the Cooling Tower ON/OFF, with respect to the temperature ofthe water. This temperature is sensed with a RTD sensor fitted onto the water tank below the cooling tower.
A Cooling Tower works on the principle of forced Fan Cooling(Incuced Draft).The water in the cooling tower is made to flow with a lot of resistance (thru fiberpacks/fills). During that flow the Fan motor sucks the heat out thereby cooling the water to maximum of 1-2 degrees below the external ambient temperature. Afterthe water has cooled to this temperature, the Fan motor continues to run uselessly, as further cooling of water is not possible. It is at this point that ADCA stops theFan motor and restarts only after the temperature of water has increased.
Any Industry using a Cooling Tower for any application, of any Make, of any Capacity, Internally or Externally mounted, with D.O.L or Star Delta Starter Director Gear driven Fan, etc.Our clients include from : Pharma, Chemical, Plastic, Foundaries, Agro, FMCG, Centrallised Air Conditioning / Refrigeration, Textiles,
Cement Plants, Fertiliser Plants, 5 Star Hotels, etc.
The Fan motor runs for the required time only.
The unnecessary running of the FAN motor is thus avoided, thereby saving a lot of ENERGY / POWER & WATER.This results in recurring savings for your company, without sacrificing the cooling efficiency.These are to the tune of up to 60% whereby you recover the cost of ADCA in just 30-45 days !!!
These savings particularly increase during Night shifts, Winter Season, when the load on the Cooling Tower is less etc.
In Industrial enviroments our customers have clocked up to 70% of Electricity savings.Please refer the savings chart for Electricity saved with ADCA.
S A V I N G S C H A R T *
COOL ARTS-SB DIGITAL “ADCA” HELPS YOU SAVE ON YOUR ELECTRICITY
BILLS TO THE TUNE OF UPTO 60% WITH A PAYBACK PERIOD OF JUST 30-45 DAYS
COOL ARTS-SB DIGITAL “ADCA” HELPS YOU SAVE ON YOUR ELECTRICITY
BILLS TO THE TUNE OF UPTO 60% WITH A PAYBACK PERIOD OF JUST 30-45 DAYSCOOL ARTS-SB DIGITAL “ADCA” HELPS YOU SAVE ON YOUR ELECTRICITY
BILLS TO THE TUNE OF UPTO 60% WITH A PAYBACK PERIOD OF JUST 30-45 DAYS
COOL ARTS-SB DIGITAL “ADCA” HELPS YOU SAVE ON YOUR ELECTRICITY
BILLS TO THE TUNE OF UPTO 60% WITH A PAYBACK PERIOD OF JUST 30-45 DAYS
METHOD OF REFERRING THE ABOVE CHART :For e.g. Consider the case of 5 h.p motorNormal consumption of units in 26 days (24 hrs) Rs.9,312.00
Units Consumed in 26 days (24Hrs) 932 unitsAmount @Rs. 4/- per unit (932 X 4) Rs.3,728.00
These figures indicated are am approximate guide line and under testconditions, the savings may vary from case to case basis
With ADCA and savings @60%
Nett Amount saved (9312 - 3728) Rs.5,584.00*
F O R C O N T I N U O U S R U N N I N G O F M O T O R F O R 2 4 H O U R S F O R 2 6 D A Y SMOTOR
CAPACITY
(H.p.)
MOTOR
CAPACITY
(H.p.)
Normal Consumption
(@ Rs. 4/- Unit)
Normal Consumption
(@ Rs. 4/- Unit)
Consumption with ADCA
@ 50% savings (@ Rs. 4/- Unit)
Consumption with ADCA
@ 50% savings (@ Rs. 4/- Unit)
Consumption with ADCA
@ 60% savings (@ Rs. 4/- Unit)
Consumption with ADCA
@ 60% savings (@ Rs. 4/- Unit)
UNITS AMOUNT UNITS UNITSAMOUNT AMOUNTSAVINGS SAVINGS
1.0
5.0
7.5
10.0
20.0
466
2328
3491
4655
9310
1,864.0
9,312.0
13,964.0
18,620.0
37,240.0
233
1164
1746
2328
4655
932.0
4,656.0
6,984.0
9,312.0
18,620.0
932.0
4,656.0
6,984.0
9,312.0
18,620.0
744.0
3,724.0
5,584.0
7,448.0
14,896.0
1,118.0
5,587.0
8,378.0
11,172.0
22,344.0
186
931
1396
1862
3724
The Actual Savings with ADCA can be Monitored & Calculated with built-in Motor ON / Motor OFF Hours meters* The Actual Savings with ADCA can be Monitored & Calculated with built-in Motor ON / Motor OFF Hours meters*
SALIENT FEATURES OF DIGITAL ADCA :Completely Automatic Operation
Continuous Digital Display of Actual Water Temperature
Individually settable MOTOR ON & MOTOR OFF temp. (0-80°C)
(This feature customises ADCA to your system)
Independently settable Hooter(warning) temp. (0-80°C)
(In actual temp. overshoots, the set Hooter temp.its relay operates)
Built-in Water Level Controller for 2 levels ( Upper & Lower)
(Connect to your makeup water pump to control water level)
MOTOR ON & MOTOR OFF Hour meters provided
(Hour meters help you Calculate ,Verify cum Monitor the savings)
Can be connected to Motor of any capacity, with any kind of starter.
Automatic switch over to Manual mode in Emergency(By pass)
RTD sensor with extension rod and fixing brackets provided
Can be fixed with your existing MOTOR & STARTER
DIN Instrument in Sturdy Metal body to suit Industrial environment
Optional 4~20mA O/p. and Motor Time Interlock for additional safety
configeration
Completely Automatic Operation
Continuous Digital Display of Actual Water Temperature
Individually settable MOTOR ON & MOTOR OFF temp. (0-80°C)
(This feature customises ADCA to your system)
Independently settable Hooter(warning) temp. (0-80°C)
(In actual temp. overshoots, the set Hooter temp.its relay operates)
Built-in Water Level Controller for 2 levels ( Upper & Lower)
(Connect to your makeup water pump to control water level)
MOTOR ON & MOTOR OFF Hour meters provided
(Hour meters help you Calculate ,Verify cum Monitor the savings)
Can be connected to Motor of any capacity, with any kind of starter.
Automatic switch over to Manual mode in Emergency(By pass)
RTD sensor with extension rod and fixing brackets provided
Can be fixed with your existing MOTOR & STARTER
DIN Instrument in Sturdy Metal body to suit Industrial environment
Optional 4~20mA O/p. and Motor Time Interlock for additional safety
configeration
TECHNICAL SPECIFICATIONS
Auxiliary Supply : 230 VAC/110 VAC, 50Hz ±15%
Power Consumption : 13.8 VA (max.)
Temp. Display : 1.0”, 7 segment LED, (3 Digits)
Display Accuracy : ± 1 Digit
Setting Range : 0-80°C
O/p Relay Ratings : 5A @ 230 VAC (Resistive)
Sensor for Temp. : RTD - Pt100 - 3 wire
Sensor for WLC : SS 304 prods
Time Interlock : Adjustable 0-18 minutes - optional
4-20mA O/p. : 4mA ~ 0°C and 20mA ~ 50°C - optional
Mounting :Panel(96*96) / Wall mounting
Weight : 2600 gms.
Dimensions (mm) : 200 (h) x 200(d) x145 (w)
S1REDS1
RED
1 2 3 4 5 6 7 8 9
NO4 C4
WATER PUMPWATER PUMP
SENSOR - RTD -Pt100SENSOR - RTD -Pt100
AUX. SUPPLYAUX. SUPPLY
L N E NC3C1 C3NC1
10 11 12 13 14 15 16 17 18
HOOTER/OVERLOADHOOTER/
OVERLOAD
NO2 NC2
H/MOFFH/MOFF
H/MONH/MON
C.T-FAN
230V
S2WH.S2
WH.S3
WH.S3
WH.P1
REFP1
REFP2L.LP2L.L
P2U.LP2U.L
WATER LEVEL SENSORSWATER LEVEL SENSORS
NC4
+ –+ –4 - 20mA O/p.4 - 20mA O/p.
Manufactured by :
Cogent Controls205, Vinay Industrial. Estate., Chincholi Bunder Link Road,Malad-W, Mumbai - 400 064 Tel: 28750421/20Email: [email protected] /[email protected] : www.cogentcontrols.com
/ColorImageDict > /JPEG2000ColorACSImageDict > /JPEG2000ColorImageDict > /AntiAliasGrayImages false /DownsampleGrayImages true /GrayImageDownsampleType /Bicubic /GrayImageResolution 300 /GrayImageDepth -1 /GrayImageDownsampleThreshold 1.50000 /EncodeGrayImages true /GrayImageFilter /DCTEncode /AutoFilterGrayImages true /GrayImageAutoFilterStrategy /JPEG /GrayACSImageDict > /GrayImageDict > /JPEG2000GrayACSImageDict > /JPEG2000GrayImageDict > /AntiAliasMonoImages false /DownsampleMonoImages true /MonoImageDownsampleType /Bicubic /MonoImageResolution 1200 /MonoImageDepth -1 /MonoImageDownsampleThreshold 1.50000 /EncodeMonoImages true /MonoImageFilter /CCITTFaxEncode /MonoImageDict > /AllowPSXObjects false /PDFX1aCheck false /PDFX3Check false /PDFXCompliantPDFOnly false /PDFXNoTrimBoxError true /PDFXTrimBoxToMediaBoxOffset [ 0.00000 0.00000 0.00000 0.00000 ] /PDFXSetBleedBoxToMediaBox true /PDFXBleedBoxToTrimBoxOffset [ 0.00000 0.00000 0.00000 0.00000 ] /PDFXOutputIntentProfile () /PDFXOutputCondition () /PDFXRegistryName (http://www.color.org) /PDFXTrapped /Unknown
/Description >>> setdistillerparams> setpagedevice