Date
MY HOME LIGHT AND AUTOMATION
2Division Appareillage et Système Résidentiels
ApartmentVilla
My home SCS bus system was designed with:system dimension and features for houses (residential)installation method close to the traditional installationaesthetic integrated with wd and des offer
Introduction
3Division Appareillage et Système Résidentiels
L
System compositionNOT ONE GENERAL CENTRAL UNIT
NO CENTRALIZED CONFIGURATION
Power supplyControls
N
Actuators
Loads
27V BUS
4Division Appareillage et Système Résidentiels
SCS bus characteristics27V D.C. NOT POLARIZED POWER SUPPLY AND DIGITAL DATA
Sender
Receiver
Information0 1 0 1 0 1 0 1 0 1 0 1
L230V
N
System composition
5Division Appareillage et Système Résidentiels
Catalogue
USER INTERFACES
ACTUATORS(ON/OFF)
DIMMERS
INTERFACES
ACCESSORIES
6Division Appareillage et Système Résidentiels
SOME MH DEVICE ARE IN COMMON WITH LM SYSTEM.
FOR THIS REASON YOU CAN USE THE LM CONFIGURATION RULES AND SYSTEM LIMITS.
Catalogue
7Division Appareillage et Système Résidentiels
Incandescent
Discharge
Halogen
Fluorescent
LED
Motors ON/OFF
Motors up/downright/left
Loads typology driven: most of the typology
Catalogue
8Division Appareillage et Système Résidentiels
Configuration
9Division Appareillage et Système Résidentiels
Relating to different products or different choices there are 2 main types of configuration:
PHYSICAL CONFIGURATION USING JUMPERSGreen for the address and the blue ones are for functioning mode.
VIRTUAL CONFIGURATIONAvailable ONLY for automation and temperature control system. It is a
SW able to configure the devices through the gateway (MH200N, F454).
Configuration
10Division Appareillage et Système Résidentiels
3° Level
Project & Download:ONLY for Lighting Management.
1° Level
PhysicalUsing jumpers.
81 addresses
A=0-9PL=1-9
Configuration
2° Level
175 addresses
A=0-10PL=0-15
Virtual
11Division Appareillage et Système Résidentiels
Actuator addressing mode
The addresses of the actuator depending by the configuration of the site A and PL.
For each area it is possible to set a max of 9 PL for each Area (max 9).In order to link an actuator to a group, it is necessary to add a jumper in the site G (group).
Socket Jumpers Notes
[A] AreaActuator address
From11 to 99Numeric jumpers 1÷9
[PL] Light point
[M] Mode From 1÷4 Numeric and blue jumpers 1÷9 [G] Group Group address Numeric Jumpers from 1 to 9
Physical configuration
12Division Appareillage et Système Résidentiels
Addressing and control type
Also the control devices have the configuration sockets A and PL in order to set the receiver of the messages (actuators).
Physical configuration
13Division Appareillage et Système Résidentiels
Physical configuration
POINT -POINT CONTROLDirect control to one actuator identified by a “room number” and a “light point number”.
ROOM CONTROLDirect control to all the actuatorsidentified by the same room number (site A).
14Division Appareillage et Système Résidentiels
Physical configuration
GROUP CONTROLDirect control to all the actuatorswhich perform particular functionseven if they belong to differentrooms and are identified by the same“group number”.
15Division Appareillage et Système Résidentiels
Physical configuration
GENERAL CONTROLDirect control to all the system actuators
16Division Appareillage et Système Résidentiels
CONFIGURATION EXAMPLE
Physical configuration
17Division Appareillage et Système Résidentiels
The functioning mode
Physical configuration
18Division Appareillage et Système Résidentiels
The blue jumpers (including also some numbers) are used for the mode of work.
Physical configuration
19Division Appareillage et Système Résidentiels
Controls operation modes
Light functioning modes:
ON timed command
ON command
OFF command
Pushbutton command
ON / OFF command
Automatism functioning modes:
UP / DOWN bistable command
UP / DOWN monostable command
Jumpers
PUL
ON
OFF
O/I
M
1-8
Physical configuration
20Division Appareillage et Système Résidentiels
Physical configuration
CONTROLS for Scheduler
21Division Appareillage et Système Résidentiels
Enable
Disable
Enable/disable
Timed ON 2 sec - 10 min
Blinking (from 0,5 to 5 sec)
Set the adjustment level (dimmer) (from 10 to 90 %)
Scenario recall (from 1 to 9)
SOFT START and SOFT STOP
Recall and program of the scenario module (from 1 to 16)
Door lock control
Sound diffusion control
Timed ON (from 5 sec to 99 min 45 sec)
Auxiliary input management
The “SPEcial” functioning modality
Physical configuration
22Division Appareillage et Système Résidentiels
Using the Virtual Configuration , there are the same configuration rules of the physical one, but there are also some improvement:
Example: F411/4
Physical configuration Virtual configuration
APL1PL2PL3PL4M
A1PL1M1
A2PL2M2
A3PL3M3
A4PL4M4
One area for all the PL.Also the mode of work is
in commonEach PL can became independent from the
others
Virtual configuration
23Division Appareillage et Système Résidentiels
PC Connections Gateway Systems
Web Server - F454
Scheduler- MH200N
Suitcase 3504 o 3503N
Ethe
rnet
cab
le
Virtual configuration
24Division Appareillage et Système Résidentiels
With devices with ID and VIRT labels
Virtual configuration
Devices description
Reference number
Configuration
25Division Appareillage et Système Résidentiels
Basic scenarios configuration
EASY SCENARIOS WITH LIGHTS AND MOTORS
4 scenarios per Unit (command)16 scenarios per DIN module (memory)Configure the device (physical-virtual)Customizable by the end-user (push & learn)
Easy to set-upPush & Learn
Modulo scenari.wmv
Scenario module
4 scenarios command
26Division Appareillage et Système Résidentiels
Memory module
SAVE THE SYSTEM STATE IN BLACK-OUT SITUATION
• It needs an A/PL address• To save address it can be used in area 0
A=PL=
• 1 module for every system
(phisical extension included)
PL
A
1 to 9
0
Memory module
Easy to set-upPush & Learn
Modulo memoria.wmv
27Division Appareillage et Système Résidentiels
INSTALLATION RULES AND
LIMITS
28Division Appareillage et Système Résidentiels
System limits
DISTANCE
ABSORPTION
ADDRESSES LOGICAL LIMITS
PHYSICAL LIMITS
Installation rules and limits
29Division Appareillage et Système Résidentiels
Free BUS cabling topology
Star connections Free connection
Just one rule: no closed ring!
Installation rules and limits
PHYSICAL LIMITS
30Division Appareillage et Système Résidentiels
Power supply Actuator Control
250m MAX 500m MAX
Installation rules and limits
PHYSICAL LIMITS
31Division Appareillage et Système Résidentiels
9 Areas
9 PL for every area
9 x 9 = 81 addresses
LOGICAL LIMITS
Installation rules and limits
Using physical configuration
9 Groups
32Division Appareillage et Système Résidentiels
11 Areas
16 PL for every area
(16 x 11)- 1 = 175 addresses
LOGICAL LIMITS
Installation rules and limits
The address 00 doesn’t exist
Using virtual configuration
255 Groups