Current Status of the APS LINAC and SR / Booster Klystron High-Voltage Power Supplies and the 352-MHz RFTS G. Trento, A. Cours Accelerator Systems Division Argonne National Laboratory Work supported by the U.S. Department of Energy, Office of Science, under Contract No. DE-AC02-06CH11357.

Transcript of Current Status of the APS LINAC and SR / Booster Klystron ... · Current Status of the APS LINAC...

Page 1: Current Status of the APS LINAC and SR / Booster Klystron ... · Current Status of the APS LINAC and SR / Booster Klystron High-Voltage Power Supplies and the 352-MHz RFTS G. Trento,

Current Status of the APS LINAC and SR / Booster Klystron High-Voltage Power

Supplies and the 352-MHz RFTS

G. Trento, A. CoursAccelerator Systems DivisionArgonne National LaboratoryWork supported by the U.S. Department of Energy, Office of Science, under Contract No. DE-AC02-06CH11357.

Page 2: Current Status of the APS LINAC and SR / Booster Klystron ... · Current Status of the APS LINAC and SR / Booster Klystron High-Voltage Power Supplies and the 352-MHz RFTS G. Trento,

LINAC Modulator

Advanced Photon Source, Argonne National Laboratory

2

Switch

C

L

Cell 1

C

L

C

L

C

L

Cell 8

Stangenes PT

Thales TH2128

PFN40-kV, 30kJ/sec

E2V Thyratron CX1836A

PLC

2 // N = 8 cells (3.2µH / 44nF)

EPICS

R

Page 3: Current Status of the APS LINAC and SR / Booster Klystron ... · Current Status of the APS LINAC and SR / Booster Klystron High-Voltage Power Supplies and the 352-MHz RFTS G. Trento,

LINAC Modulator System

Advanced Photon Source, Argonne National Laboratory

3

PFN Cabinet Internals Klystron Tank Assembly

Thyratron

Page 4: Current Status of the APS LINAC and SR / Booster Klystron ... · Current Status of the APS LINAC and SR / Booster Klystron High-Voltage Power Supplies and the 352-MHz RFTS G. Trento,

CX1836A Thyratron Operation Lifespan

Advanced Photon Source, Argonne National Laboratory

4

0

5,000

10,000

15,000

20,000

25,000

30,000

35,000

0 5 10 15 20 25 30 35

Ope

ratio

nal H

ours

Historical Tube #

• Unpredictable life span

• Short average life time: 17,300 hrs.

• High tube consumption rate: 2.4 tubes/year

• Growing tube price: $18,300 as of April 2012

• High filament energy consumption: 26,000 kW*hrs./year

• 2012 operating cost: $45,200

• High-voltage triggering pulses: up to 1,500 V

Page 5: Current Status of the APS LINAC and SR / Booster Klystron ... · Current Status of the APS LINAC and SR / Booster Klystron High-Voltage Power Supplies and the 352-MHz RFTS G. Trento,

Thyratron vs. Solid-State Switch

Advanced Photon Source, Argonne National Laboratory

5

Thyratron Solid-State Switch

Peak Forward Voltage, kV 70 48 (60)*

Peak Anode Current, kA 10 7 (10)*

Rate of Rise (di/dt), kA/µs 10 30

Triggering Pulses Up to 1,500 V Fiber-optic

Filament Power, Watts 610 0

* Numbers in the parentheses are for non-repetitive voltage or current.

S56-12 Solid-State Switch

Page 6: Current Status of the APS LINAC and SR / Booster Klystron ... · Current Status of the APS LINAC and SR / Booster Klystron High-Voltage Power Supplies and the 352-MHz RFTS G. Trento,

S56-12 Solid State Switch10K Pulses @1pps, 42 kV and 4500 A

Advanced Photon Source, Argonne National Laboratory

6

Courtesy of H. Sanders

Page 7: Current Status of the APS LINAC and SR / Booster Klystron ... · Current Status of the APS LINAC and SR / Booster Klystron High-Voltage Power Supplies and the 352-MHz RFTS G. Trento,

Thyratron vs. Solid-State Switch cont.

Advanced Photon Source, Argonne National Laboratory

7

Thyratron Solid-State Switch

Unit Price ~ $18,300 US ~ $9,000 US

Average Life Time, hrs. 17,300 Theoretically much longer

Switch Failures per Year 2.4 --

Annual Operating Cost ~ $45,200 (6 RF Stations) Theoretically much better

Triggering Pulses Up to 1,500 V Fiber-optic

Repairable No Yes

Chemical Waste Problems Yes No

Domestic Manufacturer No Yes

S56-12 installed within Modulator L3 has > 9k hours of operation.

Page 8: Current Status of the APS LINAC and SR / Booster Klystron ... · Current Status of the APS LINAC and SR / Booster Klystron High-Voltage Power Supplies and the 352-MHz RFTS G. Trento,

28KV PFN WAVEFORMThyratron versus Solid-State Switch

Advanced Photon Source, Argonne National Laboratory

8

Modulator 4 Thyratron. Modulator 3 Solid-State.

VPFN

VPRIVPRI

VPFN

Page 9: Current Status of the APS LINAC and SR / Booster Klystron ... · Current Status of the APS LINAC and SR / Booster Klystron High-Voltage Power Supplies and the 352-MHz RFTS G. Trento,

PFN CapacitorOriginal Exceeded 100x Lifetime Specification

Advanced Photon Source, Argonne National Laboratory

9

Old & New PFN Capacitor

Page 10: Current Status of the APS LINAC and SR / Booster Klystron ... · Current Status of the APS LINAC and SR / Booster Klystron High-Voltage Power Supplies and the 352-MHz RFTS G. Trento,

Modulator Control System

Advanced Photon Source, Argonne National Laboratory

10

Old: Allen-Bradley Controller• Obsolete PLC hardware & chipset.• Obsolete cathode ray tube HMI. • Obsolete PLC software.• Obsolete HMI software.• Communication protocol no longer

supported by EPICS.

New: Automation Direct Controller• New PLC hardware & chipset.• LCD HMI – long lasting.• Current PLC low cost software.• Free HMI software.• EPICS supported driver.• Low cost hardware.

Page 11: Current Status of the APS LINAC and SR / Booster Klystron ... · Current Status of the APS LINAC and SR / Booster Klystron High-Voltage Power Supplies and the 352-MHz RFTS G. Trento,

Modulator Control System cont.

Advanced Photon Source, Argonne National Laboratory

11

Old: Allen-Bradley Controller• Limited amount of information

transmitted PLC↔EPICS, quantity128 - 16 bit words.

• Table transfer - discrete and integers (16 bit).

• Open Frame.

New: Automation Direct Controller• Large amount of information transmitted

via floating point (32 bit) and discrete.• Microprocessor monitored by EPICS.• RF Group standardized PLC.• Chassis construction with filtered

connectors.• Last unit installed May 2014.

Page 12: Current Status of the APS LINAC and SR / Booster Klystron ... · Current Status of the APS LINAC and SR / Booster Klystron High-Voltage Power Supplies and the 352-MHz RFTS G. Trento,

Advanced Photon Source, Argonne National Laboratory

12

2MW DC POWER SYSTEM FOR SR / BOOSTER116k 150k Hours of Operation

Page 13: Current Status of the APS LINAC and SR / Booster Klystron ... · Current Status of the APS LINAC and SR / Booster Klystron High-Voltage Power Supplies and the 352-MHz RFTS G. Trento,

Motorized Fused Disconnect

Advanced Photon Source, Argonne National Laboratory

13

• Unit available from OEM.• Specified to operate 750 X

prior to maintenance.• Installation completed 11/2011.

• OEM disavowed knowledge of its existence yet sold replacement parts at a premium price.

• Obsolete.• Averaged 2 failures / year after sacrificial rollers installed.

This actually increased reliability!• Concrete foundation deteriorated and sourced moisture to

GPO3. • Violent open / close action wore out the mechanical

components.

Old- ABB New - SQD

Page 14: Current Status of the APS LINAC and SR / Booster Klystron ... · Current Status of the APS LINAC and SR / Booster Klystron High-Voltage Power Supplies and the 352-MHz RFTS G. Trento,

Transformer / Rectifier Analysis

Advanced Photon Source, Argonne National Laboratory

14

RF5 TR SET OIL

0 3 2

173142

0 0 0

247

120

0

50

100

150

200

250

300

Apr-01 Sep-02 Jan-04 May-05 Oct-06 Feb-08

Date

Dis

solv

ed G

as A

naly

sis

Ethylene (ppm) Acetylene (ppm)

Dissolved Gas AnalysisAcetylene – severe arcing activitiesEthylene – overheated oil

Page 15: Current Status of the APS LINAC and SR / Booster Klystron ... · Current Status of the APS LINAC and SR / Booster Klystron High-Voltage Power Supplies and the 352-MHz RFTS G. Trento,

RF5 Service Report

Advanced Photon Source, Argonne National Laboratory

15

• 1 Failed capacitor.• Qty. 4 Damaged 16-Ω, 300-W resistors.• Loose transformer ground connection.• Carbon deposit on components and walls.• Loose transformer core block hardware. • ~1% of diodes damaged.

Page 16: Current Status of the APS LINAC and SR / Booster Klystron ... · Current Status of the APS LINAC and SR / Booster Klystron High-Voltage Power Supplies and the 352-MHz RFTS G. Trento,

May 2014 Maintenance Period – RF2

Advanced Photon Source, Argonne National Laboratory

16

TR Set capacitor bank removal.

4 Failed Capacitors.

Page 17: Current Status of the APS LINAC and SR / Booster Klystron ... · Current Status of the APS LINAC and SR / Booster Klystron High-Voltage Power Supplies and the 352-MHz RFTS G. Trento,

May 2014 Maintenance Period – RF3

Advanced Photon Source, Argonne National Laboratory

17

• Plagued by intermittent crowbars during 2014-1.• Oil Acetylene Content = 878ppm.• Root Cause: poor banana jack / plug mechanical connection.

RF3 TR Set diode stack connector fault.

Page 18: Current Status of the APS LINAC and SR / Booster Klystron ... · Current Status of the APS LINAC and SR / Booster Klystron High-Voltage Power Supplies and the 352-MHz RFTS G. Trento,

Radiation Aged Tetrode Cable

Advanced Photon Source, Argonne National Laboratory

18

• Caused intermittent mod-anode regulation.

Insulation Damaged

Mod-Anode Tank Internals

Page 19: Current Status of the APS LINAC and SR / Booster Klystron ... · Current Status of the APS LINAC and SR / Booster Klystron High-Voltage Power Supplies and the 352-MHz RFTS G. Trento,

2-MW DC KPS Control Interface

Advanced Photon Source, Argonne National Laboratory

19

Old: Manufacture Design• Obsolete boards and ICs. • 486 PC running Windows95 GUI. • Proprietary E²PROM program.• GPIB communication error.• No longer supported by OEM.

New: Automation Direct Controller• Same details as LINAC Modulator

Controller.• Installation complete.

Page 20: Current Status of the APS LINAC and SR / Booster Klystron ... · Current Status of the APS LINAC and SR / Booster Klystron High-Voltage Power Supplies and the 352-MHz RFTS G. Trento,

Crowbar Ignitron Trigger5C22 JAN8613 S33A-4

Advanced Photon Source, Argonne National Laboratory

20

Vendor’s test data 16 kV @3.2 kApk

Page 21: Current Status of the APS LINAC and SR / Booster Klystron ... · Current Status of the APS LINAC and SR / Booster Klystron High-Voltage Power Supplies and the 352-MHz RFTS G. Trento,

352-MHz RFTS Line Diagram

Advanced Photon Source, Argonne National Laboratory

21

Page 22: Current Status of the APS LINAC and SR / Booster Klystron ... · Current Status of the APS LINAC and SR / Booster Klystron High-Voltage Power Supplies and the 352-MHz RFTS G. Trento,

Pulsed-Mode Conditioning Principle

Advanced Photon Source, Argonne National Laboratory

22

SignalGenerator

InterlockSwitch

Manual Attenuator RF Switch

4-40dBVoltage Control

Attenuator

Pulse Generator

Klystron Circulator Cavity

Cold CathodeGauge

Power Monitor

Added for test.

RF Conditioning - The objective is always to “touch” surface area with RF; “burn” particulates and induce controlled gas layers desorption (they enhance the secondary electron emission coefficient and cause “local desorption outbursts” which could facilitate arcing events). -Mircea Stirbet

Page 23: Current Status of the APS LINAC and SR / Booster Klystron ... · Current Status of the APS LINAC and SR / Booster Klystron High-Voltage Power Supplies and the 352-MHz RFTS G. Trento,

Methodology

Advanced Photon Source, Argonne National Laboratory

23

20 us / 20 ms pulses

50 us / 20 ms pulses

500 us / 20 ms pulses CW

Pulse length of 20-50-100-200-500us-1-2-5-10ms with fixed repetition time of 20 ms and finally CW

time

Power

• Regulate rf power as a function of vacuum.• Apply a longer repetition rate than the vacuum reading delay.• Reduce average power and minimize energy delivered to an unconditioned coupler

with rf pulses, then increase duration.

Page 24: Current Status of the APS LINAC and SR / Booster Klystron ... · Current Status of the APS LINAC and SR / Booster Klystron High-Voltage Power Supplies and the 352-MHz RFTS G. Trento,

RFTS Conditioning Method Comparisonto Achieve 100-kW CW

CW ONLY FPC ID# Conditioning Hours

ANL-B01 453

ANL-22 496

ANL-23 473

Pulsed CWComponent Conditioning Hours

FPC C2 48

Tuner ANL-09 54

FPC ANL-25 44

FPC ANL-26 53

Advanced Photon Source, Argonne National Laboratory

24

Page 25: Current Status of the APS LINAC and SR / Booster Klystron ... · Current Status of the APS LINAC and SR / Booster Klystron High-Voltage Power Supplies and the 352-MHz RFTS G. Trento,

FPC Prototype & RFTS 200-kW CW Commissioning

Advanced Photon Source, Argonne National Laboratory

25

vacuum

rf power

VCA process

RFTS Shielding -TLD Deep Dose 11 mR/h at door/window.

Page 26: Current Status of the APS LINAC and SR / Booster Klystron ... · Current Status of the APS LINAC and SR / Booster Klystron High-Voltage Power Supplies and the 352-MHz RFTS G. Trento,

S38 Cavity Pressure Run 2013-2 Machine Start-up

Advanced Photon Source, Argonne National Laboratory

26

Vacuum Trip Levels are 5e-8 Torr.

Page 27: Current Status of the APS LINAC and SR / Booster Klystron ... · Current Status of the APS LINAC and SR / Booster Klystron High-Voltage Power Supplies and the 352-MHz RFTS G. Trento,

S38 Component 100-kW Test Results

Advanced Photon Source, Argonne National Laboratory

27

• Conditioning terminated at 82kW @1mS pulse.

• RF Fingers and Bellow temperatures > 100° C (US, DS and Aisle), not during operation(?).

• No finger stock found in cavities (?).

C1 Mechanical Tuner ANL-21 C2 Mechanical Tuner ANL-13 would not achieve vacuum < 3.5x10-8 Torryet conditioned to 100kW CW.

C1 FPC MTM-11 no issues.C1 HOM Damper 535ED-05 no issues.

C2 FPC ANL-21

• Prior arcing noted & continued.

Page 28: Current Status of the APS LINAC and SR / Booster Klystron ... · Current Status of the APS LINAC and SR / Booster Klystron High-Voltage Power Supplies and the 352-MHz RFTS G. Trento,

Advanced Photon Source, Argonne National Laboratory

28

ReferencesCours A., Trento G., “Replacing Thyratron in the APS LINAC Modulators with Solid-State Switches and Allen-Bradley Controllers with AD PLC”, RF-TN-2013-011.

Sander H., Glidden S., “Compact, High Current, High Voltage Solid State Switches for Accelerator Application”, Applied Pulsed Power, 2014.

Montesinos E. (CERN); Trento G. (ANL-APS), “Optimal RF Conditioning of the Advanced Photon Source (APS) Fundamental Power Coupler”, CERN-ATS-Note-2013-031 TECH.

Trento G., Bromberek D., Morrison L., “Sector 38 Cavity Tuners and High Order Mode Damper RF Test Stand Conditioning Results”, RF-TN-2013-012.

AcknowledgementOur gratitude goes to ASD-RF Group &ADM, AES-MOM & MED and ANL-HP personnel for their efforts.ASD-RF: Roy Agner, Mike Douell, Mike Drackley, Bruce Epperson, Tim Jonasson, Dave Meyer

and Mark Moser.AES-MOM: Cheryl Giacomi, Mark Martens, Wayne Michalek, CJ Sarne and Robert Wilson.AES-MED: Andre McKenzie and John Pace.ANL-HP: David Fieramosca, Lauren Gagan and John Vacca.ASD-ADM: Jim Lang

Page 29: Current Status of the APS LINAC and SR / Booster Klystron ... · Current Status of the APS LINAC and SR / Booster Klystron High-Voltage Power Supplies and the 352-MHz RFTS G. Trento,

Thank you for your attention.

Questions?