CSEPRO Multiprotection Series
06 07
186 5C 0EI
SCADA Compatible
1A/5A50/60Hz
Site Selectable
LogicProgramming
6-DigitalInput
& Outputs
Metering&
Control
Event, Fault&
OscilloscopicRecord
CE TT IOO NRP FeederMotor
GeneratorTransformer
W x H x D125.5x156x233
mm
THE CSEPRO RANGE OFFERS COMPREHENSIVE PROTECTION SOLUTIONS AT ALL POWER SYSTEM LEVELS SUCH AS :
Transformer Management
Feeder Management
Stand Alone Breaker Fail Protection
Directional/Non-Directional Overcurrent
Load shedding Protection
Motor Management
> Transmission Generation and Distribution
> Industrial
l
l
l
l
l
l
Customer Benefitsl
l
l
l
l
l
50/60Hz Nominal Frequency (Site Selectable)
Wide Range Auxiliary Supply (No options required while ordering)
Self CT shorting Modular Design
Wide range of communication protocols
One single configuration software – Designer Suit-M6
1A/5A Rated CT (Site Selectable)
CSEProF Series F120
CSEPRO- Distribution/Feeder Protection Series F
F200 F220 F240 F260 F300 F400 F500ANSI
CT Inputs - 4 5 4 4 4 - 4
VT inputs 4 - - - 3 3 4 4
Opto Inputs (max) 4 6 4 6 4 6 6 6
Output Contacts (max) 4 6 4 6 6 6 6 6
Function Keys/Hotkeys llll l l ll
Interlocking Logic - - - - - l ll
Protection
3 Phase overcurrent 50/51P - lll l l - l
Ground fault 50/51N - lll l l - l
Phase directional 67P - - - - l - - -
Ground Fault directional 67N - - - - l - - -
Sensitive Earthfault 50/51SN - - l- - - - -
Restricted earthfault 64 - - ll - l - l
Voltage controlled overcurrent 51V - - - - - l - l
Negative sequence overcurrent 46 - lll l l - l
Thermal overload 49 - lll l l - l
Undercurrent 37 - - - l - - - l
Over/Under voltage 27/59 l- - - - l ll
Residual over voltage 59N l- - - - l ll
Negative sequence overvoltage 47 l- - - - l ll
Over/Under frequency 81O/U - - - - - - ll
Rate of change of frequency 87R - - - - - - ll
Circuit breaker failure 50BF llll l l ll
Autoreclose 79 ll- l - l ll
Broken conductor 46BC - lll l l - l
Cold load pick-up - lll l l - l
Inrush blocking - lll l l - l
Trip Circuit Supervision 74TC llll l l ll
Communication
Front (USB) lll l l ll
Rs485 Modbus lll l l ll
Modbus on Fiber Optics
RJ45 Modbus TCP/IP
IEC60870-5-103 on Fiber Optics
RJ45 IEC60870-5-101
RS485 IEC60870-5-103
RJ45-IEC61850
SNTP-Time Synch-RJ45
Webserver on RJ45
l
Optional-Based on Ordering Information
lllll l ll
lllll l ll
lllll l ll
lllll l ll
lllll l ll
lllll l ll
lllll l ll
lllll l ll
l
1312
CSEPROF500CSEP F500 provides a complete Feeder protection solution with voltage current & frequency monitoring. With IEC61850 communication , the unit becomes suitable for SCADA.
RO
CSEPROF Series offers 8 variants for Feeder protection. Based on application & cost, user can select the different model in current, voltage & frequency protection range.
CSEPROF240CSEP F240 is a multi protection over-current relay with REF & Auto recloser feature.
RO