CLIENT: OCEANRIG VESSEL: CORCOVADO · rp-qt-127b rev.0 content section 01 – executive summary...
Transcript of CLIENT: OCEANRIG VESSEL: CORCOVADO · rp-qt-127b rev.0 content section 01 – executive summary...
RP-QT-127B Rev.0
QUALITECH INSPEÇÃO, REPARO E MANUTENÇÃO LTDA.
GENERAL NDT INSPECTION
CLIENT: OCEANRIG
VESSEL: CORCOVADO
PO N°: ORBRZ-0055-2015 WO N°: 1173-4
Date: 28/12/2015 Version: Original Volume: 1 of 1
RP-QT-127B Rev.0
CONTENT
SECTION 01 – EXECUTIVE SUMMARY REPORT
SECTION 02 – 232.145 – MPI/LOAD TEST REPORT – TEMPORARY PADEYE WBTS1
SECTION 03 – 312.171 – MPI REPORT – DEAD LINE ANCHOR MAIN WELL AFT
SECTION 04 – 312.271 – MPI REPORT – DEAD LINE ANCHOR AUX WELL FWD
SECTION 05 – 331.200 – MPI REPORT – RAM BLOCK BOP LOWER PART
SECTION 06 – 334.911 – MPI / LP REPORT – DIVERTER RUNNING TOOL
SECTION 07 – 3335.321 – MPI / EC REPORT – RISER SPIDER DOGS
SECTION 08 – 335.935.005 – MPI / EC REPORT – RISER RUNNING TOOL #1
SECTION 09 – 335.935.010 – MPI / EC REPORT – RISER RUNNING TOOL #2
SECTION 10 – 341.235 – MPI REPORT – HYDRARACKER GRIPPER HEAD
SECTION 11 – 361.300 – MPI/UT REPORT – KNUCKLE BOOM #3 CYLINDER BRACKET
SECTION 12 – 361.400 – MPI/UT REPORT – KNUCKLE BOOM #4 CYLINDER BRACKET
SECTION 13 – 361.425.015 – CERTIFICATE OF THOROUGH EXAMINATION – KBC#4 WIRE ROPE
SECTION 14 – 365.135.012 – CERTIFICATE OF THOROUGH EXAMINATION – MOONPOOL WINCH #6
WIRE ROPE
SECTION 15 – 455 – CERTIFICATE OF THOROUGH EXAMINATION – RISER BRIDLE WIRE ROPE
SECTION 16 – 455 – CERTIFICATE OF THOROUGH EXAMINATION – SWIVEL HOOKS
SECTION 17 – 503.745 – PHOTOGRAPHIC REPORT – DERRICK SALA BLOCK
SECTION 18 – 721.111.031 – PHOTOGRAPHIC REPORT – SEA CHEST VENT LINE
SECTION 19 – 813.500 – PHOTOGRAPHIC REPORT – 8” BELLOWS FLEXIBLE FLANGE
SECTION 20 – TECHNICIAN CERTIFICATE
SECTION 21 – COMPANY CERTIFICATE
Page 1 of 3
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev.4
MAGNETIC PARTICLE INSPECTION REPORT
Client: Ocean Rig Location: Corcovado (NS-40) Report Number: MPI-1173-051
P.O. Nr: ORBRZ-0055-2015 Qualitech WO: 1173 Inspection Procedure: PI-QT-003 Rev.2
SFI Code: 232.145 Client WO: 2015-09233 Surface: Acceptable
Equipment Description: Temporary Pad Eye for WBTS1. Qty: 1 SWL: 1 Ton
Serial Number: N/A Reference Drawing N°: N/A
Specification: AWS D1.1 Material: Carbon Steel Manufacture: Unknown
Comment: Area Inspected: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical area of the Temporary Pad Eyes for WBTS1. Result: No defects were found at time of inspection. Conclusion: Acceptable to the Specification. Recommendations: Authorized for use. Continuation Attached: Yes
Name / Qualification: Allan Paulino Siqueira
ASNT LII MT-3001 R1
Signed / Stamp:
Date of Inspection: November 16th, 2015
Approved By:
Equipment/Magnetization
Magnetization Technique
Coil
Magnetization : Longitudinal Current Flow : Alternating
Ligth Type:
x Natural Artificial
x Yoke Pull 10lbs
Yes Pole Spacing:
4” to 6 “
Ilumination:1200 lux
Flux Indicator:
Berthold x Burmah Strip
Equipment Description: MY-2 Voltage: 110V Serial No:1303093
Test Method
Test Medium Dry X Colour Wet Wet Fluorescent
Particle Type: RW222
Contrast Type: 104
Antifoaming Type: 787
Black Light Unit: N/A
FL/Sample AT:
X
UV:0,1 to 0,4L
Visible:0,4 to 1,2L
Batch No:
Maker: Metal Check
Maker: Metal Check
Maker: Metal Check
Model: N/A
Batch Nr: 9884
Batch Nr: 7863
Batch Nr: 8733
Serial Nr: N/A
Page 2 of 3
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev.4
MAGNETIC PARTICLE INSPECTION REPORT
Client: Ocean Rig Report Number: MPI-1173-051
P.O. Nr: ORBRZ-0055-2015 WO: 1173 Location: Corcovado (NS-40)
Item: Temporary Pad Eyes for WBTS1. Inspection Details: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical area of the Temporary Pad Eyes for WBTS1.
Name / Qualification: Allan Paulino Siqueira
ASNT LII MT-3001 R1
Signed / Stamp:
Date of Inspection: November 16th, 2015
Approved By:
Page 1 of 1
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-122B Rev.2
LOAD TEST REPORT
Client: Ocean Rig Location: Corcovado NS-40 CERTIFICATE NO: LT-1173-001
P.O. Nr: ORBRZ-0055-2015 WO: 1173 Client PMS Number:
SFI Code: 232.145 Client WO: 2015-09233
Date of Test: 16th, Nov 2015 Date recommended for Next Test: 15th, Nov 2016
Equipment: Jacking Kit Serial Number: QT-2716
Manufacture: Power Team / DeWit 10000 psi Material: Carbon Steel
Specification: BS EN 13001 Reference Drawing N°: N/A
I certify on behalf of Company, association or engineer named below that on 16 November 2015, the items described were tested and thereafter examined and were found to be free from cracks, flaws or other defects in accordance with the standard.
Name / Qualification: Allan P. Siqueira
ASNT L.II / IRATA L.I
Signed / Stamp: Date of Inspection: 16th, November 2015
Approved By:
Test Details
Serial Number Description of Equipment Location SWL Proof Load
N/A Temporary Pad Eye for WBTS1 WBTS1 1 ton 50% Over the SWL
Page 1 of 2
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev.4
MAGNETIC PARTICLE INSPECTION REPORT
Client: Ocean Rig Location: Corcovado (NS-40) Report Number: MPI-1173-057
P.O. Nr: ORBRZ-0055-2015 Qualitech WO: 1173 Inspection Procedure: PI-QT-003 Rev.2
SFI Code: 312.171 Client WO: 2015-08664 Surface: Acceptable
Equipment Description: Deadline Anchor, Main Well AFT. Qty: 1 SWL: 200.000 lbs
Serial Number: E-200-NOV2009-66 Reference Drawing N°: V3434
Specification: ASTM E-709 Material: Carbon Steel Manufacture: NOV
Comment: Area Inspected: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical area of the Deadline Anchor, Main Well AFT. Result: No defects were found at time of inspection. Conclusion: Acceptable to the Specification. Recommendations: Authorized for use. Continuation Attached: Yes
Name / Qualification: Allan Paulino Siqueira
ASNT LII MT-3001 R1
Signed / Stamp:
Date of Inspection: November 19th, 2015
Approved By:
Equipment/Magnetization
Magnetization Technique
Coil
Magnetization : Longitudinal Current Flow : Alternating
Ligth Type:
x Natural Artificial
x Yoke Pull 10lbs
Yes Pole Spacing:
4” to 6 “
Ilumination:1200 lux
Flux Indicator:
Berthold x Burmah Strip
Equipment Description: MY-2 Voltage: 110V Serial No:1303093
Test Method
Test Medium Dry X Colour Wet Wet Fluorescent
Particle Type: RW222
Contrast Type: 104
Antifoaming Type: 787
Black Light Unit: N/A
FL/Sample AT:
x
UV:0,1 to 0,4L
Visible:0,4 to 1,2L
Batch No:
Maker: Metal Check
Maker: Metal Check
Maker: Metal Check
Model: N/A
Batch Nr: 9884
Batch Nr: 7863
Batch Nr: 8733
Serial Nr: N/A
Page 2 of 2
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev.4
MAGNETIC PARTICLE INSPECTION REPORT
Client: Ocean Rig Report Number: MPI-1173-057
P.O. Nr: ORBRZ-0055-2015 WO: 1173 Location: Corcovado (NS-40)
Item: Deadline Anchor, Main Well AFT. Inspection Details: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical area of the Deadline Anchor, Main Well AFT.
Name / Qualification: Allan Paulino Siqueira
ASNT LII MT-3001 R1
Signed / Stamp:
Date of Inspection: November 19th, 2015
Approved By:
Page 1 of 2
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev.4
MAGNETIC PARTICLE INSPECTION REPORT
Client: Ocean Rig Location: Corcovado (NS-40) Report Number: MPI-1173-056
P.O. Nr: ORBRZ-0055-2015 Qualitech WO: 1173 Inspection Procedure: PI-QT-003 Rev.2
SFI Code: 312.271 Client WO: 2015-08665 Surface: Acceptable
Equipment Description: Deadline Anchor, Aux Well FWD. Qty: 1 SWL: 200.000 lbs
Serial Number: E-200-NOV2009-67 Reference Drawing N°: V3435
Specification: ASTM E-709 Material: Carbon Steel Manufacture: NOV
Comment: Area Inspected: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical area of the Deadline Anchor, Aux Well FWD. Result: No defects were found at time of inspection. Conclusion: Acceptable to the Specification. Recommendations: Authorized for use. Continuation Attached: Yes
Name / Qualification: Allan Paulino Siqueira
ASNT LII MT-3001 R1
Signed / Stamp:
Date of Inspection: November 19th, 2015
Approved By:
Equipment/Magnetization
Magnetization Technique
Coil
Magnetization : Longitudinal Current Flow : Alternating
Ligth Type:
x Natural Artificial
x Yoke Pull 10lbs
Yes Pole Spacing:
4” to 6 “
Ilumination:1200 lux
Flux Indicator:
Berthold x Burmah Strip
Equipment Description: MY-2 Voltage: 110V Serial No:1303093
Test Method
Test Medium Dry X Colour Wet Wet Fluorescent
Particle Type: RW222
Contrast Type: 104
Antifoaming Type: 787
Black Light Unit: N/A
FL/Sample AT:
x
UV:0,1 to 0,4L
Visible:0,4 to 1,2L
Batch No:
Maker: Metal Check
Maker: Metal Check
Maker: Metal Check
Model: N/A
Batch Nr: 9884
Batch Nr: 7863
Batch Nr: 8733
Serial Nr: N/A
Page 2 of 2
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev.4
MAGNETIC PARTICLE INSPECTION REPORT
Client: Ocean Rig Report Number: MPI-1173-056
P.O. Nr: ORBRZ-0055-2015 WO: 1173 Location: Corcovado (NS-40)
Item: Deadline Anchor, Aux Well FWD. Inspection Details: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical area of the Deadline Anchor, Aux Well FWD.
Name / Qualification: Allan Paulino Siqueira
ASNT LII MT-3001 R1
Signed / Stamp:
Date of Inspection: November 19th, 2015
Approved By:
Page 1 of 6
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev.4
MAGNETIC PARTICLE INSPECTION REPORT
Client: Ocean Rig Location: Corcovado (NS-40) Report Number: MPI-1173-058
P.O. Nr: ORBRZ-0055-2015 Qualitech WO: 1173 Inspection Procedure: PI-QT-003 Rev.2
SFI Code: 331.200 Client WO: 2015-07573 Surface: Acceptable
Equipment Description: RAM Block – BOP Lower Part Qty: 1 set SWL: N/A
Serial Number: 2001-2398-515 & 2001-2398-516 Reference Drawing N°:
Specification: ASTM E-709 Material: Carbon Steel Manufacture: NOV
Comment: Area Inspected: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical area of the Ram Block – BOP Lower Part. Result: No defects were found at time of inspection. Conclusion: Acceptable to the Specification. Recommendations: Authorized for use. Continuation Attached: Yes
Name / Qualification: Allan Paulino Siqueira
ASNT LII MT-3001 R1
Signed / Stamp:
Date of Inspection: November 20th, 2015
Approved By:
Equipment/Magnetization
Magnetization Technique
Coil
Magnetization : Longitudinal Current Flow : Alternating
Ligth Type:
x Natural Artificial
x Yoke Pull 10lbs
Yes Pole Spacing:
4” to 6 “
Ilumination:1200 lux
Flux Indicator:
Berthold x Burmah Strip
Equipment Description: MY-2 Voltage: 110V Serial No:1303093
Test Method
Test Medium Dry X Colour Wet Wet Fluorescent
Particle Type: RW222
Contrast Type: 104
Antifoaming Type: 787
Black Light Unit: N/A
FL/Sample AT:
X
UV:0,1 to 0,4L
Visible:0,4 to 1,2L
Batch No:
Maker: Metal Check
Maker: Metal Check
Maker: Metal Check
Model: N/A
Batch Nr: 9884
Batch Nr: 7863
Batch Nr: 8733
Serial Nr: N/A
Page 2 of 6
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev.4
MAGNETIC PARTICLE INSPECTION REPORT
Client: Ocean Rig Report Number: MPI-1173-058
P.O. Nr: ORBRZ-0055-2015 WO: 1173 Location: Corcovado (NS-40)
Item: Ram Block – BOP Lower Part. Inspection Details: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical area of the Ram Block – BOP Lower Part.
Informations: 18 ¾’’ 15000
W/O: 3204658 P/N: 20012363
Name / Qualification: Allan Paulino Siqueira
ASNT LII MT-3001 R1
Signed / Stamp:
Date of Inspection: November 20th, 2015
Approved By:
Page 3 of 6
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev.4
MAGNETIC PARTICLE INSPECTION REPORT
Client: Ocean Rig Location: Corcovado (NS-40) Report Number: MPI-1173-059
P.O. Nr: ORBRZ-0055-2015 Qualitech WO: 1173 Inspection Procedure: PI-QT-003 Rev.2
SFI Code: 331.200 Client WO: 2015-07573 Surface: Acceptable
Equipment Description: RAM Block – BOP Lower Part Qty: 1 set SWL: N/A
Serial Number: 20012091-1549 & 20012091-1550 Reference Drawing N°:
Specification: ASTM E-709 Material: Carbon Steel Manufacture: NOV
Comment: Area Inspected: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical area of the Ram Block – BOP Lower Part. Result: No defects were found at time of inspection. Conclusion: Acceptable to the Specification. Recommendations: Authorized for use. Continuation Attached: Yes
Name / Qualification: Allan Paulino Siqueira
ASNT LII MT-3001 R1
Signed / Stamp:
Date of Inspection: November 20th, 2015
Approved By:
Equipment/Magnetization
Magnetization Technique
Coil
Magnetization : Longitudinal Current Flow : Alternating
Ligth Type:
x Natural Artificial
x Yoke Pull 10lbs
Yes Pole Spacing:
4” to 6 “
Ilumination:1200 lux
Flux Indicator:
Berthold x Burmah Strip
Equipment Description: MY-2 Voltage: 110V Serial No:1303093
Test Method
Test Medium Dry X Colour Wet Wet Fluorescent
Particle Type: RW222
Contrast Type: 104
Antifoaming Type: 787
Black Light Unit: N/A
FL/Sample AT:
X
UV:0,1 to 0,4L
Visible:0,4 to 1,2L
Batch No:
Maker: Metal Check
Maker: Metal Check
Maker: Metal Check
Model: N/A
Batch Nr: 9884
Batch Nr: 7863
Batch Nr: 8733
Serial Nr: N/A
Page 4 of 6
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev.4
MAGNETIC PARTICLE INSPECTION REPORT
Client: Ocean Rig Report Number: MPI-1173-059
P.O. Nr: ORBRZ-0055-2015 WO: 1173 Location: Corcovado (NS-40)
Item: Ram Block – BOP Lower Part. Inspection Details: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical area of the Ram Block – BOP Lower Part.
Informations: 18 – 5 / 10 / 15M 5 - 7 +NN
W/O: 3149699 P/N: 20012093
Name / Qualification: Allan Paulino Siqueira
ASNT LII MT-3001 R1
Signed / Stamp:
Date of Inspection: November 20th, 2015
Approved By:
Page 5 of 6
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev.4
MAGNETIC PARTICLE INSPECTION REPORT
Client: Ocean Rig Location: Corcovado (NS-40) Report Number: MPI-1173-060
P.O. Nr: ORBRZ-0055-2015 Qualitech WO: 1173 Inspection Procedure: PI-QT-003 Rev.2
SFI Code: 331.200 Client WO: 2015-07573 Surface: Acceptable
Equipment Description: RAM Block – BOP Lower Part Qty: 1 set SWL: N/A
Serial Number: RJ082 Reference Drawing N°:
Specification: ASTM E-709 Material: Carbon Steel Manufacture: NOV
Comment: Area Inspected: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical area of the Ram Block – BOP Lower Part. Result: No defects were found at time of inspection. Conclusion: Acceptable to the Specification. Recommendations: Authorized for use. Continuation Attached: Yes
Name / Qualification: Allan Paulino Siqueira
ASNT LII MT-3001 R1
Signed / Stamp:
Date of Inspection: November 20th, 2015
Approved By:
Equipment/Magnetization
Magnetization Technique
Coil
Magnetization : Longitudinal Current Flow : Alternating
Ligth Type:
x Natural Artificial
x Yoke Pull 10lbs
Yes Pole Spacing:
4” to 6 “
Ilumination:1200 lux
Flux Indicator:
Berthold x Burmah Strip
Equipment Description: MY-2 Voltage: 110V Serial No:1303093
Test Method
Test Medium Dry X Colour Wet Wet Fluorescent
Particle Type: RW222
Contrast Type: 104
Antifoaming Type: 787
Black Light Unit: N/A
FL/Sample AT:
X
UV:0,1 to 0,4L
Visible:0,4 to 1,2L
Batch No:
Maker: Metal Check
Maker: Metal Check
Maker: Metal Check
Model: N/A
Batch Nr: 9884
Batch Nr: 7863
Batch Nr: 8733
Serial Nr: N/A
Page 6 of 6
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev.4
MAGNETIC PARTICLE INSPECTION REPORT
Client: Ocean Rig Report Number: MPI-1173-060
P.O. Nr: ORBRZ-0055-2015 WO: 1173 Location: Corcovado (NS-40)
Item: Ram Block – BOP Lower Part. Inspection Details: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical area of the Ram Block – BOP Lower Part.
Informations: 18 – 5M NXT 18 – 10 NXT
W/O: 3176910 P/N: 20012093
Name / Qualification: Allan Paulino Siqueira
ASNT LII MT-3001 R1
Signed / Stamp:
Date of Inspection: November 20th, 2015
Approved By:
Page 1 of 2
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev.4
MAGNETIC PARTICLE INSPECTION REPORT
Client: Ocean Rig Location: Corcovado (NS-40) Report Number: MPI-1173-055
P.O. Nr: ORBRZ-0055-2015 Qualitech WO: 1173 Inspection Procedure: PI-QT-003 Rev.2
SFI Code: 334.911 Client WO: 2015-07476 Surface: Acceptable
Equipment Description: Diverter Running Tool. Qty: 1 set SWL: N/A
Serial Number: 133 Reference Drawing N°: N/A
Specification: ASTM E-709 Material: Carbon Steel Manufacture: NOV
Comment: Area Inspected: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical area of the Diverter Running Tool. Result: No defects were found at time of inspection. Conclusion: Acceptable to the Specification. Recommendations: Authorized for use. Continuation Attached: Yes
Name / Qualification: Allan Paulino Siqueira
ASNT LII MT-3001 R1
Signed / Stamp:
Date of Inspection: November 18th, 2015
Approved By:
Equipment/Magnetization
Magnetization Technique
Coil
Magnetization : Longitudinal Current Flow : Alternating
Ligth Type:
x Natural Artificial
x Yoke Pull 10lbs
Yes Pole Spacing:
4” to 6 “
Ilumination:1200 lux
Flux Indicator:
Berthold x Burmah Strip
Equipment Description: MY-2 Voltage: 110V Serial No:1303093
Test Method
Test Medium Dry X Colour Wet Wet Fluorescent
Particle Type: RW222
Contrast Type: 104
Antifoaming Type: 787
Black Light Unit: N/A
FL/Sample AT:
X
UV:0,1 to 0,4L
Visible:0,4 to 1,2L
Batch No:
Maker: Metal Check
Maker: Metal Check
Maker: Metal Check
Model: N/A
Batch Nr: 9884
Batch Nr: 7863
Batch Nr: 8733
Serial Nr: N/A
Page 2 of 2
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev.4
MAGNETIC PARTICLE INSPECTION REPORT
Client: Ocean Rig Report Number: MPI-1173-055
P.O. Nr: ORBRZ-0055-2015 WO: 1173 Location: Corcovado (NS-40)
Item: Diverter Running Tool. Inspection Details: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical area of the Diverter Running Tool.
Shaft P/N: 20026654 Dogs P/N: 20026088
Name / Qualification: Allan Paulino Siqueira
ASNT LII MT-3001 R1
Signed / Stamp:
Date of Inspection: November 18th, 2015
Approved By:
Page 1 of 2
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-102B Rev.3
LIQUID PENETRANT INSPECTION REPORT
Client: Ocean Rig Date: November 18th, 15 Qualitech WO: 1173 Report Number: LPI-1173-003
P.O. Nr: ORBRZ-0055-2015 Location: Corcovado Inspection Procedure: PI-QT-004 Rev.1
SFI Code: 334.911 Client WO: 2015-07476 Surface: Acceptable
Equipment Description: Diverter Running Tool Housing. Qty: 4 Housings Size: N/A
Serial Number: 133 Reference Drawing N°:
Specification: ASME Section V Material: Stainless Steel Manufacture: NOV
Comment: Area Inspected: As per clients request a Visual and Liquid penetrating Inspection was carried out on 100% off the accessible critical and stress areas of the Diverter Running Tool Housing. Result: No defects were found at time of inspection Conclusion: Acceptable to Specification Recommendations: Authorized for use Continuation Attached: Yes
Name / Qualification: Flavio Madureira
ABENDI SNQC: 3670
Signed / Stamp:
Date of Inspection: November 18th, 2015
Approved By:
Test Method
Test Medium x Visible Fluorescent
Penetrant Type: VP-30 Water Washable:x
Solvent removable :
Post emulsifier :
Batch Nr:
Cleaner type: Water
Developer: D-70
Black Light Unit: N/A
Maker: Metal Check
Maker: N/A
Maker: Metal Check
Maker: N/A
Batch Nr: 20890
Batch Nr:
Batch Nr: 21035
Serial Nr:
Component Temp: ≥4ᵒC to ≤40ᵒC Dwell Time: ≥10 min to≤60min Dev. Time: ≥10 min to ≤60min
UV-A Irradiance: uw/cm2 Ambient Light Level: 1500 LUX
Page 2 of 2
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-102B Rev.3
LIQUID PENETRANT INSPECTION REPORT
Client: Ocean Rig Report Number: LPI-1173-003
P.O. Nr: ORBRZ-0055-2015 WO: 1173 Location: Corcovado
Item: Diverter Running Tool Housing. Inspection Details: As per clients request a Visual and Liquid penetrating Inspection was carried out on 100% off the accessible critical and stress areas of the Diverter Running Tool Housing.
FOTO
Name / Qualification:
Flavio Madureira ABENDI SNQC: 3670
Signed / Stamp:
Date of Inspection: November 18th, 2015
Approved By:
Page 1 of 2
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev.4
MAGNETIC PARTICLE INSPECTION REPORT
Client: Ocean Rig Location: Corcovado (NS-40) Report Number: MPI-1173-052
P.O. Nr: ORBRZ-0055-2015 Qualitech WO: 1173 Inspection Procedure: PI-QT-003 Rev.2
SFI Code: 335.321 Client WO: 2015-07570 Surface: Acceptable
Equipment Description: Riser Spider Dogs. Qty: 4 SWL: N/A
Serial Number: V3475 / ABS: 11532100 Reference Drawing N°: N/A
Specification: ASTM E-709 Material: Carbon Steel Manufacture: NOV
Comment: Area Inspected: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical area of the Riser Spider Dogs. Result: No defects were found at time of inspection. Conclusion: Acceptable to the Specification. Recommendations: Authorized for use. Continuation Attached: Yes
Name / Qualification: Allan Paulino Siqueira
ASNT LII MT-3001 R1
Signed / Stamp:
Date of Inspection: November 17th, 2015
Approved By:
Equipment/Magnetization
Magnetization Technique
Coil
Magnetization : Longitudinal Current Flow : Alternating
Ligth Type:
x Natural Artificial
x Yoke Pull 10lbs
Yes Pole Spacing:
4” to 6 “
Ilumination:1200 lux
Flux Indicator:
Berthold x Burmah Strip
Equipment Description: MY-2 Voltage: 110V Serial No:1303093
Test Method
Test Medium Dry X Colour Wet Wet Fluorescent
Particle Type: RW222
Contrast Type: 104
Antifoaming Type: 787
Black Light Unit: N/A
FL/Sample AT:
X
UV:0,1 to 0,4L
Visible:0,4 to 1,2L
Batch No:
Maker: Metal Check
Maker: Metal Check
Maker: Metal Check
Model: N/A
Batch Nr: 9884
Batch Nr: 7863
Batch Nr: 8733
Serial Nr: N/A
Page 2 of 2
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev.4
MAGNETIC PARTICLE INSPECTION REPORT
Client: Ocean Rig Report Number: MPI-1173-052
P.O. Nr: ORBRZ-0055-2015 WO: 1173 Location: Corcovado (NS-40)
Item: Riser Spider Dogs. Inspection Details: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical area of the Riser Spider Dogs.
Name / Qualification: Allan Paulino Siqueira
ASNT LII MT-3001 R1
Signed / Stamp:
Date of Inspection: November 17th, 2015
Approved By:
Page 1 of 2
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-104B Rev.2
EDDY CURRENT INSPECTION REPORT
Client: Ocean Rig Date: November 17th,2015 Qualitech WO: 1173 Report Number: ECI-1173-006
P.O. Nr: ORBRZ-0055-2015 Location: Corcovado Inspection Procedure: PI-QT-005 Rev.2
SFI Code: 335.321 Client WO: 2015-07570 Surface: Acceptable
Probes Probes Serial No Frequency Gain Phase Calibration
Absolute 501257/02 135KHz-250Khzl 30dB 240 Deg 3 dB for every 0.5 mm of Coating
Bridge 603059 100KHz 46dB 130 Deg 1mm Slot to FSH
NOTE: Compensations made for variable geometry and paint thickness.
Equipment Description: Riser Spider Structural Welds.
Serial Number: V3475 / ABS: 11532100 Size: N/A
Manufacture: NOV Material: Carbon Steel Qty: 8
Specification: BSI BS EN1711 Reference Drawing N°: N/A
Comment: Area Inspected: As per clients request a Visual and Eddy Current Inspection was carried out on 100% of the accessible critical weld area of the Riser Spider Structural Welds. Result: No surface defects were found at time of inspection Conclusion: Acceptable to the Specification. Recommendations: Authorized for use Continuation Attached: Yes
Name / Qualification: Allan Paulino Siqueira
ASNT LII ET-4322 R1 / IRATA
Signed / Stamp:
Date of Inspection: November 17th, 2015
Approved By:
Equipments
Page 2 of 2
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-104B Rev.2
EDDIE CURRENT INSPECTION REPORT
Client: Ocean Rig Report Number: ECI-1173-006
P.O. Nr: ORBRZ-0055-2015 WO: 1173 Location: Corcovado
Item: Riser Spider Structural Welds. Inspection Details: As per clients request a Visual and Eddy Current Inspection was carried out on 100% of the accessible critical weld area of the Riser Spider Structural Welds. FOTO
Name / Qualification: Allan Paulino Siqueira
ASNT LII ET-4322 R1 / IRATA
Signed / Stamp:
Date of Inspection: November 17th, 2015
Approved By:
Page 1 of 2
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev.4
MAGNETIC PARTICLE INSPECTION REPORT
Client: Ocean Rig Location: Corcovado (NS-40) Report Number: MPI-1173-053
P.O. Nr: ORBRZ-0055-2015 Qualitech WO: 1173 Inspection Procedure: PI-QT-003 Rev.2
SFI Code: 335.935.005 Client WO: 2015-08452 Surface: Acceptable
Equipment Description: Riser Running Tool #1. Qty: 1 SWL: N/A
Serial Number: C335.935.005 Reference Drawing N°: N/A
Specification: ASTM E-709 Material: Carbon Steel Manufacture: NOV
Comment: Area Inspected: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical area of the Riser Running Tool #1. Result: No defects were found at time of inspection. Conclusion: Acceptable to the Specification. Recommendations: Authorized for use. Continuation Attached: Yes
Name / Qualification: Allan Paulino Siqueira
ASNT LII MT-3001 R1
Signed / Stamp:
Date of Inspection: November 18th, 2015
Approved By:
Equipment/Magnetization
Magnetization Technique
Coil
Magnetization : Longitudinal Current Flow : Alternating
Ligth Type:
x Natural Artificial
x Yoke Pull 10lbs
Yes Pole Spacing:
4” to 6 “
Ilumination:1200 lux
Flux Indicator:
Berthold x Burmah Strip
Equipment Description: MY-2 Voltage: 110V Serial No:1303093
Test Method
Test Medium Dry X Colour Wet Wet Fluorescent
Particle Type: RW222
Contrast Type: 104
Antifoaming Type: 787
Black Light Unit: N/A
FL/Sample AT:
X
UV:0,1 to 0,4L
Visible:0,4 to 1,2L
Batch No:
Maker: Metal Check
Maker: Metal Check
Maker: Metal Check
Model: N/A
Batch Nr: 9884
Batch Nr: 7863
Batch Nr: 8733
Serial Nr: N/A
Page 2 of 2
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev.4
MAGNETIC PARTICLE INSPECTION REPORT
Client: Ocean Rig Report Number: MPI-1173-053
P.O. Nr: ORBRZ-0055-2015 WO: 1173 Location: Corcovado (NS-40)
Item: Riser Running Tool #1. Inspection Details: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical area of the Riser Running Tool #1.
Running Tool #1 Dogs have not been disassembled for Inspection Name / Qualification: Allan Paulino Siqueira
ASNT LII MT-3001 R1
Signed / Stamp:
Date of Inspection: November 18th, 2015
Approved By:
Page 1 of 2
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev.4
MAGNETIC PARTICLE INSPECTION REPORT
Client: Ocean Rig Location: Corcovado (NS-40) Report Number: MPI-1173-054
P.O. Nr: ORBRZ-0055-2015 Qualitech WO: 1173 Inspection Procedure: PI-QT-003 Rev.2
SFI Code: 335.935.010 Client WO: 2015-08453 Surface: Acceptable
Equipment Description: Riser Running Tool #2. Qty: 1 SWL: N/A
Serial Number: C335.935.010 Reference Drawing N°: N/A
Specification: ASTM E-709 Material: Carbon Steel Manufacture: NOV
Comment: Area Inspected: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical area of the Riser Running Tool #2. Result: No defects were found at time of inspection. Conclusion: Acceptable to the Specification. Recommendations: Authorized for use. Continuation Attached: Yes
Name / Qualification: Allan Paulino Siqueira
ASNT LII MT-3001 R1
Signed / Stamp:
Date of Inspection: November 18th, 2015
Approved By:
Equipment/Magnetization
Magnetization Technique
Coil
Magnetization : Longitudinal Current Flow : Alternating
Ligth Type:
x Natural Artificial
x Yoke Pull 10lbs
Yes Pole Spacing:
4” to 6 “
Ilumination:1200 lux
Flux Indicator:
Berthold x Burmah Strip
Equipment Description: MY-2 Voltage: 110V Serial No:1303093
Test Method
Test Medium Dry X Colour Wet Wet Fluorescent
Particle Type: RW222
Contrast Type: 104
Antifoaming Type: 787
Black Light Unit: N/A
FL/Sample AT:
X
UV:0,1 to 0,4L
Visible:0,4 to 1,2L
Batch No:
Maker: Metal Check
Maker: Metal Check
Maker: Metal Check
Model: N/A
Batch Nr: 9884
Batch Nr: 7863
Batch Nr: 8733
Serial Nr: N/A
Page 2 of 2
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev.4
MAGNETIC PARTICLE INSPECTION REPORT
Client: Ocean Rig Report Number: MPI-1173-054
P.O. Nr: ORBRZ-0055-2015 WO: 1173 Location: Corcovado (NS-40)
Item: Riser Running Tool #2. Inspection Details: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical area of the Riser Running Tool #2.
Running Tool #2 Dogs have not been disassembled for Inspection Name / Qualification: Allan Paulino Siqueira
ASNT LII MT-3001 R1
Signed / Stamp:
Date of Inspection: November 18th, 2015
Approved By:
Page 1 of 2
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev.4
MAGNETIC PARTICLE INSPECTION REPORT
Client: Ocean Rig Location: Corcovado (NS-40) Report Number: MPI-1173-060
P.O. Nr: ORBRZ-0055-2015 Qualitech WO: 1173 Inspection Procedure: PI-QT-003 Rev.2
SFI Code: 341.235 Client WO: 2015-04101 Surface: Acceptable
Equipment Description: Main Arm Gripper Head 3 ½’’ – 13 5/8’’ Hydra Racker Aux Well. Qty: 1 SWL: N/A
Serial Number: V3416 Reference Drawing N°:
Specification: AWS D1.1 Material: Carbon Steel Manufacture: NOV
Comment: Area Inspected: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical area of the Main Arm Gripper Head 3 ½’’ – 13 5/8’’ Hydra Racker Aux. Well FWD. Result: No defects were found at time of inspection. Conclusion: Acceptable to the Specification. Recommendations: Authorized for use. Continuation Attached: Yes
Name / Qualification: Allan Paulino Siqueira
ASNT LII MT-3001 R1
Signed / Stamp:
Date of Inspection: November 26th, 2015
Approved By:
Equipment/Magnetization
Magnetization Technique
Coil
Magnetization : Longitudinal Current Flow : Alternating
Ligth Type:
x Natural Artificial
x Yoke Pull 10lbs
Yes Pole Spacing:
4” to 6 “
Ilumination:1200 lux
Flux Indicator:
Berthold x Burmah Strip
Equipment Description: MY-2 Voltage: 110V Serial No:1303093
Test Method
Test Medium Dry X Colour Wet Wet Fluorescent
Particle Type: RW222
Contrast Type: 104
Antifoaming Type: 787
Black Light Unit: N/A
FL/Sample AT:
X
UV:0,1 to 0,4L
Visible:0,4 to 1,2L
Batch No:
Maker: Metal Check
Maker: Metal Check
Maker: Metal Check
Model: N/A
Batch Nr: 9884
Batch Nr: 7863
Batch Nr: 8733
Serial Nr: N/A
Page 2 of 2
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev.4
MAGNETIC PARTICLE INSPECTION REPORT
Client: Ocean Rig Report Number: MPI-1173-060
P.O. Nr: ORBRZ-0055-2015 WO: 1173 Location: Corcovado (NS-40)
Item: Main Arm Gripper Head 3 ½’’ – 13 5/8’’ Hydra Racker Aux. Well FWD. Inspection Details: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical area of the Main Arm Gripper Head 3 ½’’ – 13 5/8’’ Hydra Racker Aux. Well FWD.
WE DO NOT INSPECTED THE PINS AND PAD EYE BECAUSE THE OPERATIONS OF THE RIG WE LOOK FORWARD TO THE NEXT OPPORTUNITY TO CONTINUE THE INSPECTION
Name / Qualification: Allan Paulino Siqueira
ASNT LII MT-3001 R1
Signed / Stamp:
Date of Inspection: November 26th, 2015
Approved By:
Page 1 of 2
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev.4
MAGNETIC PARTICLE INSPECTION REPORT
Client: Ocean Rig Location: Corcovado (NS-40) Report Number: MPI-1173-059
P.O. Nr: ORBRZ-0055-2015 Qualitech WO: 1173 Inspection Procedure: PI-QT-003 Rev.2
SFI Code: 361.300 Client WO: 2015-09323 Surface: Acceptable
Equipment Description: KBC#3 Boom Cylinder Bracket. Qty: 2 Brackets SWL: N/A
Serial Number: V3456 Reference Drawing N°:
Specification: AWS D1.1 Material: Carbon Steel Manufacture: NOV
Comment: Area Inspected: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical area of the KBC#3 Boom Cylinder Bracket. Result: No defects were found at time of inspection. Conclusion: Acceptable to the Specification. Recommendations: Authorized for use. Continuation Attached: Yes
Name / Qualification: Allan Paulino Siqueira
ASNT LII MT-3001 R1
Signed / Stamp:
Date of Inspection: November 26th, 2015
Approved By:
Equipment/Magnetization
Magnetization Technique
Coil
Magnetization : Longitudinal Current Flow : Alternating
Ligth Type:
x Natural Artificial
x Yoke Pull 10lbs
Yes Pole Spacing:
4” to 6 “
Ilumination:1200 lux
Flux Indicator:
Berthold x Burmah Strip
Equipment Description: MY-2 Voltage: 110V Serial No:1303093
Test Method
Test Medium Dry X Colour Wet Wet Fluorescent
Particle Type: RW222
Contrast Type: 104
Antifoaming Type: 787
Black Light Unit: N/A
FL/Sample AT:
X
UV:0,1 to 0,4L
Visible:0,4 to 1,2L
Batch No:
Maker: Metal Check
Maker: Metal Check
Maker: Metal Check
Model: N/A
Batch Nr: 9884
Batch Nr: 7863
Batch Nr: 8733
Serial Nr: N/A
Page 2 of 2
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev.4
MAGNETIC PARTICLE INSPECTION REPORT
Client: Ocean Rig Report Number: MPI-1173-059
P.O. Nr: ORBRZ-0055-2015 WO: 1173 Location: Corcovado (NS-40)
Item: KBC#3 Boom Cylinder Bracket. Inspection Details: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical area of the KBC#3 Boom Cylinder Bracket.
Name / Qualification: Allan Paulino Siqueira
ASNT LII MT-3001 R1
Signed / Stamp:
Date of Inspection: November 26th, 2015
Approved By:
Page 1 of 2
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 01C, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-225B Rev. 0
ULTRASONIC REPORT – WELDING - AWS
Client: Ocean Rig Location: Corcovado Report Number: UR-1173-039
P.O. Nr: ORBRZ-0055-2015 WO: 1173 Inspection Procedure PI-QT-006
SFI Code:361.300 Client WO:2015-09324 Reference Standard: AWS D1.1
Reference Drawing: MPI-1173-029 Thickness: 50 mm Welding Metal: Carbon steel Item: KBC#3 Knuckle Boom Cylinder Bracket
Reference block: V2 Surface: Acceptable
WPS: N/A Metal Base: Carbon steel
Comment: Area Inspected: As per clients request a Visual and Ultrasonic inspection was carried out on 100% of the accessible critical area of the KBC#3 Knuckle Boom Cylinder Bracket. Result: No defects were found on time of inspection. Conclusion: Acceptable to Specification. Recommendations: Continue the use. Continuation Attached: Yes
Name / Qualification: Arthur Limeira PCN#: 325529
UT Lv 2 - 3.1 & 3.2
Signed / Stamp:
Date of Inspection:
26/11/2015
Approved By:
TESTING EQUIPMENT
Manufacturer: Olympus Model: Epoch LT Serial Number: 060077601 TRANSDUCER CALIBRATION RECORD
Type
Model:
Serial Number:
Dimensions (mm)
Real Angle
Freq. (MHz)
Surface Detection
Tickness Block (mm) GP (dB) PT (dB) GV (dB)
Double Crystal
Straight Beam WKCD-10 30867 10 5 MHz TOP BWE 40 dB 0 dB 40 dB
Angle MA-45 212766 8X9 45° 4 MHz WELD 50 dB +6 dB 62 dB
Angle MA-60 212072 8X9 60° 4 MHz WELD 50 dB +6 dB 62 dB
Angle
Page 2 of 2
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 01C, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-225B Rev. 0
ULTRASONIC REPORT – WELDING - AWS
Client: Ocean Rig Report Number: UR-1173-038
P.O. Nr: ORBRZ-0055-2015 WO: 1173 Location: Corcovado
Item: KBC#3 Knuckle Boom Cylinder Bracket.
Inspection Details: As per clients request a Visual and Ultrasonic Inspection was carried out on 100% of the accessible critical area of the KBC#3 Knuckle Boom Cylinder Bracket.
Looking from AFT to FWD:
Left side Right side
Work Order: 2015-09323
Tech Acc: 361.300
Name / Qualification:
Arthur Limeira PCN#: 325529
UT Lv 2 - 3.1 & 3.2
Signed/Stamp:
Date of Inspection: 26/11/2015
Approved By:
Page 1 of 11
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev.4
MAGNETIC PARTICLE INSPECTION REPORT
Client: Ocean Rig Location: Corcovado (NS-40) Report Number: MPI-1173-029
P.O. Nr: N/A Qualitech WO: 1173 Inspection Procedure: PI-QT-003 Rev.2
SFI Code: 361-400 Client WO: 2015-09324 Surface: Brushed
Equipment Description: Knuckle Weld Boom Crane #4 Qty: 1 Size: 85t
Serial Number: V3457-2210 Reference Drawing N°: N/A
Specification: AWS D1.1 Material: Carbon Steel Manufacture: NOV
Comment: Area Inspected: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical area of the Knuckle Weld Boom Crane #4. Result: Cracks were found at time of inspection on Both Side. Conclusion: No Acceptable to the Specification. Recommendations: Repair following procedures NOV. Continuation Attached: Yes
Name / Qualification: Bruno Cerri
SNT/MT-3276
Signed / Stamp:
Date of Inspection: 16/10/2015
Approved By:
Equipment/Magnetization
Magnetization Technique
Coil
Magnetization : Longitudinal Current Flow : Alternating
Ligth Type:
x Natural Artificial
x Yoke Pull 10lbs
Yes Pole Spacing:
4” to 6 “
Ilumination:1200 lux
Flux Indicator:
Berthold x Burmah Strip
Equipment Description: MY-2 Voltage: 110V Serial No:1303093
Test Method
Test Medium Dry X Colour Wet Wet Fluorescent
Particle Type: RW222
Contrast Type: 104
Antifoaming Type: 787
Black Light Unit: N/A
FL/Sample AT:
X
UV:0,1 to 0,4L
Visible:0,4 to 1,2L
Batch No:
Maker: Metal Check
Maker: Metal Check
Maker: Metal Check
Model: N/A
Batch Nr: 9884
Batch Nr: 7863
Batch Nr: 8733
Serial Nr: N/A
Page 2 of 11
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev.4
MAGNETIC PARTICLE INSPECTION REPORT
Client: Petrobras Report Number: MPI-1173-029
P.O. Nr: N/A WO: 1173 Location: Corcovado (NS-40)
Item: Knuckle Weld Boom Crane #4 Inspection Details: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical area of the Knuckle Weld Boom Crane #4 and Cracks were found at time of inspection.
Right Side
Looking AFT to FOWARD
Name / Qualification:
Bruno Cerri SNT/MT-3276
Signed / Stamp:
Date of Inspection: 16/10/2015
Approved By:
Page 3 of 11
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev.4
MAGNETIC PARTICLE INSPECTION REPORT
Client: Petrobras Report Number: MPI-1173-029
P.O. Nr: N/A WO: 1173 Location: Corcovado (NS-40)
Item: Knuckle Weld Boom Crane #4 Inspection Details: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical area of the Knuckle Weld Boom Crane #4, cracks were found at time of inspection
Left Side
Looking AFT to FOWARD
Name & Qualification:
Bruno Cerri SNT/MT-3276
Signed/Stamp:
Date of Inspection: 16/10/2015
Approved By:
Page 4 of 11
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev.4
MAGNETIC PARTICLE INSPECTION REPORT
Client: Ocean Rig Location: Corcovado (NS-40) Report Number: MPI-1173-029
P.O. Nr: N/A Qualitech WO: 1173 Inspection Procedure: PI-QT-003 Rev.2
SFI Code: 361-400 Client WO: 2015-09324 Surface: Brushed
Equipment Description: Knuckle Weld Boom Crane #4 (After Removed Crack)
Qty: 1 Size: 85t
Serial Number: V3457-2210 Reference Drawing N°: N/A
Specification: AWS D1.1 Material: Carbon Steel Manufacture: NOV
Comment: Area Inspected: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical area of the Knuckle Weld Boom Crane #4 (After Removed Crack). Result: No defects were found at time of inspection. Conclusion: Acceptable to the Specification. Recommendations: Authorized for use. Continuation Attached: Yes
Name / Qualification: Bruno Cerri
SNT/MT-3276
Signed / Stamp:
Date of Inspection: 08/11/2015
Approved By:
Equipment/Magnetization
Magnetization Technique
Coil
Magnetization : Longitudinal Current Flow : Alternating
Ligth Type:
x Natural Artificial
x Yoke Pull 10lbs
Yes Pole Spacing:
4” to 6 “
Ilumination:1200 lux
Flux Indicator:
Berthold x Burmah Strip
Equipment Description: MY-2 Voltage: 110V Serial No:1303093
Test Method
Test Medium Dry X Colour Wet Wet Fluorescent
Particle Type: RW222
Contrast Type: 104
Antifoaming Type: 787
Black Light Unit: N/A
FL/Sample AT:
X
UV:0,1 to 0,4L
Visible:0,4 to 1,2L
Batch No:
Maker: Metal Check
Maker: Metal Check
Maker: Metal Check
Model: N/A
Batch Nr: 9884
Batch Nr: 7863
Batch Nr: 8733
Serial Nr: N/A
Page 5 of 11
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev.4
MAGNETIC PARTICLE INSPECTION REPORT
Client: Petrobras Report Number: MPI-1173-029
P.O. Nr: N/A WO: 1173 Location: Corcovado (NS-40)
Item: Knuckle Weld Boom Crane #4 (After Removed Crack). Inspection Details: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical area of the Knuckle Weld Boom Crane #4 (After Removed Crack).
Right Side
Looking AFT to FOWARD
Name & Qualification:
Bruno Cerri SNT/MT-3276
Signed/Stamp:
Date of Inspection: 08/11/2015
Approved By:
Page 6 of 11
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev.4
MAGNETIC PARTICLE INSPECTION REPORT
Client: Petrobras Report Number: MPI-1173-029
P.O. Nr: N/A WO: 1173 Location: Corcovado (NS-40)
Item: Knuckle Weld Boom Crane #4 (After Removed Crack).Inspection Details: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical area of the Knuckle Weld Boom Crane #4 (After Removed Crack).
Left Side
Looking AFT to FOWARD
Name & Qualification:
Bruno Cerri SNT/MT-3276
Signed/Stamp:
Date of Inspection: 08/11/2015
Approved By:
Page 7 of 11
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev.4
MAGNETIC PARTICLE INSPECTION REPORT
Client: Ocean Rig Location: Corcovado (NS-40) Report Number: MPI-1173-029
P.O. Nr: N/A Qualitech WO: 1173 Inspection Procedure: PI-QT-003 Rev.2
SFI Code: 361-400 Client WO: 2015-09324 Surface: Brushed
Equipment Description: Knuckle Weld Boom Crane #4 (After Re-Weld)
Qty: 1 Size: 85t
Serial Number: V3457-2210 Reference Drawing N°: N/A
Specification: AWS D1.1 Material: Carbon Steel Manufacture: NOV
Comment: Area Inspected: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical area of the Knuckle Weld Boom Crane #4 (After Re-Weld). Result: No defects were found at time of inspection. Conclusion: Acceptable to the Specification. Recommendations: Authorized for use. Continuation Attached: Yes
Name / Qualification: Bruno Cerri
SNT/MT-3276
Signed / Stamp:
Date of Inspection: 08/11/2015
Approved By:
Equipment/Magnetization
Magnetization Technique
Coil
Magnetization : Longitudinal Current Flow : Alternating
Ligth Type:
x Natural Artificial
x Yoke Pull 10lbs
Yes Pole Spacing:
4” to 6 “
Ilumination:1200 lux
Flux Indicator:
Berthold x Burmah Strip
Equipment Description: MY-2 Voltage: 110V Serial No:1303093
Test Method
Test Medium Dry X Colour Wet Wet Fluorescent
Particle Type: RW222
Contrast Type: 104
Antifoaming Type: 787
Black Light Unit: N/A
FL/Sample AT:
X
UV:0,1 to 0,4L
Visible:0,4 to 1,2L
Batch No:
Maker: Metal Check
Maker: Metal Check
Maker: Metal Check
Model: N/A
Batch Nr: 9884
Batch Nr: 7863
Batch Nr: 8733
Serial Nr: N/A
Page 8 of 11
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev.4
MAGNETIC PARTICLE INSPECTION REPORT
Client: Petrobras Report Number: MPI-1173-029
P.O. Nr: N/A WO: 1173 Location: Corcovado (NS-40)
Item: Knuckle Weld Boom Crane #4 (After Re-Weld). Inspection Details: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical area of the Knuckle Weld Boom Crane #4 (After Re-Weld).
Right Side
Looking AFT to FOWARD
Name & Qualification:
Bruno Cerri SNT/MT-3276
Signed/Stamp:
Date of Inspection: 08/11/2015
Approved By:
Page 9 of 11
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev.4
MAGNETIC PARTICLE INSPECTION REPORT
Client: Ocean Rig Location: Corcovado (NS-40) Report Number: MPI-1173-029
P.O. Nr: N/A Qualitech WO: 1173 Inspection Procedure: PI-QT-003 Rev.2
SFI Code: 361-400 Client WO: 2015-09324 Surface: Brushed
Equipment Description: Knuckle Weld Boom Crane #4 (Bracket Weld) Qty: 1 Size: 85t
Serial Number: V3457-2210 Reference Drawing N°: N/A
Specification: AWS D1.1 Material: Carbon Steel Manufacture: NOV
Comment: Area Inspected: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical area of the Knuckle Weld Boom Crane #4 (Bracket Weld). Result: No defects were found at time of inspection. Conclusion: Acceptable to the Specification. Recommendations: Authorized for use. Continuation Attached: Yes
Name / Qualification: Bruno Cerri
SNT/MT-3276
Signed / Stamp:
Date of Inspection: 09/11/2015
Approved By:
Equipment/Magnetization
Magnetization Technique
Coil
Magnetization : Longitudinal Current Flow : Alternating
Ligth Type:
x Natural Artificial
x Yoke Pull 10lbs
Yes Pole Spacing:
4” to 6 “
Ilumination:1200 lux
Flux Indicator:
Berthold x Burmah Strip
Equipment Description: MY-2 Voltage: 110V Serial No:1303093
Test Method
Test Medium Dry X Colour Wet Wet Fluorescent
Particle Type: RW222
Contrast Type: 104
Antifoaming Type: 787
Black Light Unit: N/A
FL/Sample AT:
X
UV:0,1 to 0,4L
Visible:0,4 to 1,2L
Batch No:
Maker: Metal Check
Maker: Metal Check
Maker: Metal Check
Model: N/A
Batch Nr: 9884
Batch Nr: 7863
Batch Nr: 8733
Serial Nr: N/A
Page 10 of 11
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev.4
MAGNETIC PARTICLE INSPECTION REPORT
Client: Petrobras Report Number: MPI-1173-029
P.O. Nr: N/A WO: 1173 Location: Corcovado (NS-40)
Item: Knuckle Weld Boom Crane #4 (Bracket Weld) Inspection Details: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical area of the Knuckle Weld Boom Crane #4 (Bracket Weld)
Right Side
Looking AFT to FOWARD
Name & Qualification:
Bruno Cerri SNT/MT-3276
Signed/Stamp:
Date of Inspection: 09/11/2015
Approved By:
Page 11 of 11
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-097B Rev.4
MAGNETIC PARTICLE INSPECTION REPORT
Client: Petrobras Report Number: MPI-1173-029
P.O. Nr: N/A WO: 1173 Location: Corcovado (NS-40)
Item: Knuckle Weld Boom Crane #4 (Bracket Weld) Inspection Details: As per clients request a Visual and Magnetic Particle Inspection was carried out on 100% of the accessible critical area of the Knuckle Weld Boom Crane #4 (Bracket Weld)
Left Side
Looking AFT to FOWARD
Name & Qualification:
Bruno Cerri SNT/MT-3276
Signed/Stamp:
Date of Inspection: 09/11/2015
Approved By:
Page 1 of 1
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240 www.qualitechirm.com
Quality for safety RP-QT-117B Rev.3
PHOTOGRAPHIC INSPECTION REPORT
Client: Ocean Rig Location: Corcovado Report Number: PIR-1173-013
P.O. Nr: ORBRZ-0055-2015 WO: 1173 Reference Document: N/A
SFI Code: 361.400 Client WO: 2015-09324
Item: KBC#4 Boom Cylinder Bracket.
Details: Visual Survey Inspection was carried out on the KBC#4 Boom Cylinder Bracket.
Corrective Action: Redo welds or repair affected Areas.
New Welds out of the required procedure with the following defects and failures:
Welds without finishing, lot of pores and Lack of Fusion
Name / Qualification: Allan Paulino Siqueira
ASNT II / IRATA I
Signed / Stamp:
Date of Inspection: November 21th,2015
Approved By:
Page 1 of 2
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 01C, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-225B Rev. 0
ULTRASONIC REPORT – WELDING - AWS
Client: Ocean Rig Location: Corcovado Report Number: UR-1173-038
P.O. Nr: ORBRZ-0055-2015 WO: 1173 Inspection Procedure PI-QT-006
SFI Code:361.400 Client WO:2015-09324 Reference Standard: AWS D1.1
Reference Drawing: MPI-1173-029 Thickness: 50 mm Welding Metal: Carbon steel Item: KBC#4 Knuckle Boom Cylinder Bracket
Reference block: V2 Surface: Acceptable
WPS: N/A Metal Base: Carbon steel
Comment: Area Inspected: As per clients request a Visual and Ultrasonic inspection was carried out on 100% of the accessible critical area of the Knuckle Boom Crane #4 Result: It has been found indication of LACK OF FUSION on the welds at the plates in both sides. Conclusion: Not Acceptable to Specification. Recommendations: Repair Area where LACK OF FUSION was detected. Continuation Attached: Yes
Name / Qualification: Arthur Limeira PCN#: 325529
UT Lv 2 - 3.1 & 3.2
Signed / Stamp:
Date of Inspection:
20/11/2015
Approved By:
TESTING EQUIPMENT
Manufacturer: Olympus Model: Epoch LT Serial Number: 060077601 TRANSDUCER CALIBRATION RECORD
Type
Model:
Serial Number:
Dimensions (mm)
Real Angle
Freq. (MHz)
Surface Detection
Tickness Block (mm) GP (dB) PT (dB) GV (dB)
Double Crystal
Straight Beam WKCD-10 30867 10 5 MHz TOP BWE 40 dB 0 dB 40 dB
Angle MA-45 212766 8X9 45° 4 MHz WELD 50 dB +6 dB 62 dB
Angle MA-60 212072 8X9 60° 4 MHz WELD 50 dB +6 dB 62 dB
Angle
Page 2 of 2
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box 01C, Anil, Jacarepaguá – RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-225B Rev. 0
ULTRASONIC REPORT – WELDING - AWS
Client: Ocean Rig Report Number: UR-1173-038
P.O. Nr: ORBRZ-0055-2015 WO: 1173 Location: Corcovado
Item: KBC#4 Knuckle Boom Cylinder Bracket.
Inspection Details: As per clients request a Visual and Ultrasonic Inspection was carried out on 100% of the accessible critical area of the KBC#4 Knuckle Boom Cylinder Bracket.
Looking from AFT to FWD:
Left side Right side
LACK OF FUSION 30 MM, LOCATED 45 MM DEEP LACK OF FUSION 25 MM, LOCATED 45 MM DEEP
THE DEVICE SHOWING THE INDICATION
Work Order: 2015-09324 Tech Acc: 361.400
Name / Qualification:
Arthur Limeira PCN#: 325529
UT Lv 2 - 3.1 & 3.2
Signed/Stamp:
Date of Inspection: 20/11/2015
Approved By:
Page 1 of 1
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-169B Rev.2
CERTIFICATE OF THOROUGH EXAMINATION
Certificate Number: CTE-1173-055
Customer: Ocean Rig Color Code: Green
Location: Corcovado Inspection Procedure: PI-QT-011
SFI Code: 361.425.015 Client WO: 2015-06908
Date of Examination: 22/11/2015 Manufacture: BRIDON
Date of Next Examination: 21/11/2016 Equipment Status: Approved
Identity No Description & Detail Of Equipment Location SWL Test Proof
Load
82656/1-1-1
WIRE ROPE FITTED WITH SOLID THIMBLE K5 8’’ WITH 66MM HOLE DIA
BY FSET OTHER END FUSED AND TAPERED
KBC #4
PORT/AFT
21.6
TONNES
N/A
Previously tested by the manufacturer
General Comment: NO DEFECT FOUND AT TIME OF INSPECTION
I certify on behalf of the firm, Company, association or technician named below that the items described herein were tested and thereafter examined and were found to be free from cracks, flaws or other defects
Name / Qualification: Allan Paulino Siqueira
ASNT II / IRATA
Signed / Stamp:
Date of Inspection: November 22th, 2015
Approved by:
This certification or Report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacture, seller, supplier repairer, or operator of any warranty, express or implied and Qualitech. Liability shall be limited to the acs and omissions of it's employees, agents and subcontractors. Under no circumstances shall Qualitech be liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse of or any defect in material, machinery, equipment, or other items other than defects in items actually inspected by Qualitech and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by Qualitech and which are covered by this certificate or report. The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to Qualitech personnel. The report does not purport to list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as a guideline only. No responsibility is assumed for the control or correction of conditions.
Page 1 of 1
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-169B Rev.2
CERTIFICATE OF THOROUGH EXAMINATION
Certificate Number: CTE-1173-064
Customer: Ocean Rig Color Code: Green
Location: Corcovado Inspection Procedure: PI-QT-011
SFI Code: 365.135.021 Client WO: 2015-09351
Date of Examination: 24/11/2015 Manufacture: CERTEX
Date of Next Examination: 23/11/2016 Equipment Status: Approved
Identity No Description & Detail Of Equipment Location SWL Test Proof
Load
453703/3-4 WIRE ROPE
19MM 6X36 IWRC GALV RHO
SOCKET CLOSED ¾’’ 18-19MM
Moon Pool
Utility Winch #6
5 TON N/A
Previously tested by the manufacturer
General Comment: NO DEFECT FOUND AT TIME OF INSPECTION
I certify on behalf of the firm, Company, association or technician named below that the items described herein were tested and thereafter examined and were found to be free from cracks, flaws or other defects
Name / Qualification: Allan Paulino Siqueira
ASNT II / IRATA
Signed / Stamp:
Date of Inspection: November 24th, 2015
Approved by:
This certification or Report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacture, seller, supplier repairer, or operator of any warranty, express or implied and Qualitech. Liability shall be limited to the acs and omissions of it's employees, agents and subcontractors. Under no circumstances shall Qualitech be liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse of or any defect in material, machinery, equipment, or other items other than defects in items actually inspected by Qualitech and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by Qualitech and which are covered by this certificate or report. The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to Qualitech personnel. The report does not purport to list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as a guideline only. No responsibility is assumed for the control or correction of conditions.
Page 1 of 2
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-169B Rev.2
CERTIFICATE OF THOROUGH EXAMINATION
Certificate Number: CTE-1173-065
Customer: Ocean Rig Color Code: Green
Location: Corcovado Inspection Procedure: PI-QT-011
SFI Code: 455 Client WO: 2015-08327
Date of Examination: 25/11/2015 Manufacture: CERTEX
Date of Next Examination: 24/11/2016 Equipment Status: Approved
Identity No Description & Detail Of Equipment Location SWL Test Proof
Load
447842-1 WIRE ROPE
48MM 6X36 IWRC GALV
RING 60.6.OF
KAUSE K2 12’’
S322 A SWIVEL KROK 30T
RF MERKEBRIKKE 30 CERTEX
RISER BRIDLE
43 TON N/A
Previously tested by the manufacturer
General Comment: NO DEFECT FOUND AT TIME OF INSPECTION
I certify on behalf of the firm, Company, association or technician named below that the items described herein were tested and thereafter examined and were found to be free from cracks, flaws or other defects
Name / Qualification: Allan Paulino Siqueira
ASNT II / IRATA
Signed / Stamp:
Date of Inspection: November 25th, 2015
Approved by:
This certification or Report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacture, seller, supplier repairer, or operator of any warranty, express or implied and Qualitech. Liability shall be limited to the acs and omissions of it's employees, agents and subcontractors. Under no circumstances shall Qualitech be liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse of or any defect in material, machinery, equipment, or other items other than defects in items actually inspected by Qualitech and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by Qualitech and which are covered by this certificate or report. The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to Qualitech personnel. The report does not purport to list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as a guideline only. No responsibility is assumed for the control or correction of conditions.
Page 2 of 2
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-169B Rev.2
CERTIFICATE OF THOROUGH EXAMINATION
Certificate Number: CTE-1173-066
Customer: Ocean Rig Color Code: Green
Location: Corcovado Inspection Procedure: PI-QT-011
SFI Code: 455 Client WO: 2015-08327
Date of Examination: 25/11/2015 Manufacture: CERTEX
Date of Next Examination: 24/11/2016 Equipment Status: Approved
Identity No Description & Detail Of Equipment Location SWL Test Proof
Load
447842-2 WIRE ROPE
48MM 6X36 IWRC GALV
RING 60.6.OF
KAUSE K2 12’’
S322 A SWIVEL KROK 30T
RF MERKEBRIKKE 30 CERTEX
RISER BRIDLE
43 TON N/A
Previously tested by the manufacturer
General Comment: NO DEFECT FOUND AT TIME OF INSPECTION
I certify on behalf of the firm, Company, association or technician named below that the items described herein were tested and thereafter examined and were found to be free from cracks, flaws or other defects
Name / Qualification: Allan Paulino Siqueira
ASNT II / IRATA
Signed / Stamp:
Date of Inspection: November 25th, 2015
Approved by:
This certification or Report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacture, seller, supplier repairer, or operator of any warranty, express or implied and Qualitech. Liability shall be limited to the acs and omissions of it's employees, agents and subcontractors. Under no circumstances shall Qualitech be liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse of or any defect in material, machinery, equipment, or other items other than defects in items actually inspected by Qualitech and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by Qualitech and which are covered by this certificate or report. The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to Qualitech personnel. The report does not purport to list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as a guideline only. No responsibility is assumed for the control or correction of conditions.
Page 1 of 8
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-169B Rev.2
CERTIFICATE OF THOROUGH EXAMINATION
Certificate Number: CTE-1173-056
Customer: Ocean Rig Color Code: Green
Location: Corcovado Inspection Procedure: PI-QT-011
SFI Code: 455 Client WO: 2015-09352
Date of Examination: 23/11/2015 Manufacture: Crosby
Date of Next Examination: 22/11/2016 Equipment Status: Approved
Identity No Description & Detail Of Equipment Location SWL Test Proof
Load
SHK-1
CROSBY ORIGINAL CERTIFICATE
CCI-2015111600303
SWIVEL HOOK SHUR-LOC WITH ROLLER BEARING
½’’ 13MM
GR-100 / G10
LIFTING LOCKER
STBD/FWD
15000 lbs N/A
Previously tested by the manufacturer
General Comment: NO DEFECT FOUND AT TIME OF INSPECTION
I certify on behalf of the firm, Company, association or technician named below that the items described herein were tested and thereafter examined and were found to be free from cracks, flaws or other defects
Name / Qualification: Allan Paulino Siqueira
ASNT II / IRATA
Signed / Stamp:
Date of Inspection: November 23th, 2015
Approved by:
This certification or Report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacture, seller, supplier repairer, or operator of any warranty, express or implied and Qualitech. Liability shall be limited to the acs and omissions of it's employees, agents and subcontractors. Under no circumstances shall Qualitech be liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse of or any defect in material, machinery, equipment, or other items other than defects in items actually inspected by Qualitech and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by Qualitech and which are covered by this certificate or report. The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to Qualitech personnel. The report does not purport to list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as a guideline only. No responsibility is assumed for the control or correction of conditions.
Page 2 of 8
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-169B Rev.2
CERTIFICATE OF THOROUGH EXAMINATION
Certificate Number: CTE-1173-057
Customer: Ocean Rig Color Code: Green
Location: Corcovado Inspection Procedure: PI-QT-011
SFI Code: 455 Client WO: 2015-09352
Date of Examination: 23/11/2015 Manufacture: Crosby
Date of Next Examination: 22/11/2016 Equipment Status: Approved
Identity No Description & Detail Of Equipment Location SWL Test Proof
Load
SHK-2
CROSBY ORIGINAL CERTIFICATE
CCI-2015111600303
SWIVEL HOOK SHUR-LOC
½’’ 13MM
GR-100 / G10
LIFTING LOCKER
STBD/FWD
15000 lbs N/A
Previously tested by the manufacturer
General Comment: NO DEFECT FOUND AT TIME OF INSPECTION
I certify on behalf of the firm, Company, association or technician named below that the items described herein were tested and thereafter examined and were found to be free from cracks, flaws or other defects
Name / Qualification: Allan Paulino Siqueira
ASNT II / IRATA
Signed / Stamp:
Date of Inspection: November 23th, 2015
Approved by:
This certification or Report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacture, seller, supplier repairer, or operator of any warranty, express or implied and Qualitech. Liability shall be limited to the acs and omissions of it's employees, agents and subcontractors. Under no circumstances shall Qualitech be liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse of or any defect in material, machinery, equipment, or other items other than defects in items actually inspected by Qualitech and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by Qualitech and which are covered by this certificate or report. The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to Qualitech personnel. The report does not purport to list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as a guideline only. No responsibility is assumed for the control or correction of conditions.
Page 3 of 8
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-169B Rev.2
CERTIFICATE OF THOROUGH EXAMINATION
Certificate Number: CTE-1173-058
Customer: Ocean Rig Color Code: Green
Location: Corcovado Inspection Procedure: PI-QT-011
SFI Code: 455 Client WO: 2015-09352
Date of Examination: 23/11/2015 Manufacture: Crosby
Date of Next Examination: 22/11/2016 Equipment Status: Approved
Identity No Description & Detail Of Equipment Location SWL Test Proof
Load
SHK-3
CROSBY ORIGINAL CERTIFICATE
CCI-2015111600303
SWIVEL HOOK SHUR-LOC
½’’ 13MM
GR-100 / G10
LIFTING LOCKER
STBD/FWD
15000 lbs N/A
Previously tested by the manufacturer
General Comment: NO DEFECT FOUND AT TIME OF INSPECTION
I certify on behalf of the firm, Company, association or technician named below that the items described herein were tested and thereafter examined and were found to be free from cracks, flaws or other defects
Name / Qualification: Allan Paulino Siqueira
ASNT II / IRATA
Signed / Stamp:
Date of Inspection: November 23th, 2015
Approved by:
This certification or Report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacture, seller, supplier repairer, or operator of any warranty, express or implied and Qualitech. Liability shall be limited to the acs and omissions of it's employees, agents and subcontractors. Under no circumstances shall Qualitech be liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse of or any defect in material, machinery, equipment, or other items other than defects in items actually inspected by Qualitech and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by Qualitech and which are covered by this certificate or report. The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to Qualitech personnel. The report does not purport to list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as a guideline only. No responsibility is assumed for the control or correction of conditions.
Page 4 of 8
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-169B Rev.2
CERTIFICATE OF THOROUGH EXAMINATION
Certificate Number: CTE-1173-059
Customer: Ocean Rig Color Code: Green
Location: Corcovado Inspection Procedure: PI-QT-011
SFI Code: 455 Client WO: 2015-09352
Date of Examination: 23/11/2015 Manufacture: Crosby
Date of Next Examination: 22/11/2016 Equipment Status: Approved
Identity No Description & Detail Of Equipment Location SWL Test Proof
Load
SHK-4
CROSBY ORIGINAL CERTIFICATE
CCI-2015111600303
SWIVEL HOOK SHUR-LOC
½’’ 13MM
GR-100 / G10
LIFTING LOCKER
STBD/FWD
15000 lbs N/A
Previously tested by the manufacturer
General Comment: NO DEFECT FOUND AT TIME OF INSPECTION
I certify on behalf of the firm, Company, association or technician named below that the items described herein were tested and thereafter examined and were found to be free from cracks, flaws or other defects
Name / Qualification: Allan Paulino Siqueira
ASNT II / IRATA
Signed / Stamp:
Date of Inspection: November 23th, 2015
Approved by:
This certification or Report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacture, seller, supplier repairer, or operator of any warranty, express or implied and Qualitech. Liability shall be limited to the acs and omissions of it's employees, agents and subcontractors. Under no circumstances shall Qualitech be liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse of or any defect in material, machinery, equipment, or other items other than defects in items actually inspected by Qualitech and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by Qualitech and which are covered by this certificate or report. The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to Qualitech personnel. The report does not purport to list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as a guideline only. No responsibility is assumed for the control or correction of conditions.
Page 5 of 8
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-169B Rev.2
CERTIFICATE OF THOROUGH EXAMINATION
Certificate Number: CTE-1173-060
Customer: Ocean Rig Color Code: Green
Location: Corcovado Inspection Procedure: PI-QT-011
SFI Code: 455 Client WO: 2015-09352
Date of Examination: 23/11/2015 Manufacture: Crosby
Date of Next Examination: 22/11/2016 Equipment Status: Approved
Identity No Description & Detail Of Equipment Location SWL Test Proof
Load
SHK-5
CROSBY ORIGINAL CERTIFICATE
CCI-2015111600303
SWIVEL HOOK SHUR-LOC
½’’ 13MM
GR-100 / G10
LIFTING LOCKER
STBD/FWD
15000 lbs N/A
Previously tested by the manufacturer
General Comment: NO DEFECT FOUND AT TIME OF INSPECTION
I certify on behalf of the firm, Company, association or technician named below that the items described herein were tested and thereafter examined and were found to be free from cracks, flaws or other defects
Name / Qualification: Allan Paulino Siqueira
ASNT II / IRATA
Signed / Stamp:
Date of Inspection: November 23th, 2015
Approved by:
This certification or Report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacture, seller, supplier repairer, or operator of any warranty, express or implied and Qualitech. Liability shall be limited to the acs and omissions of it's employees, agents and subcontractors. Under no circumstances shall Qualitech be liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse of or any defect in material, machinery, equipment, or other items other than defects in items actually inspected by Qualitech and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by Qualitech and which are covered by this certificate or report. The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to Qualitech personnel. The report does not purport to list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as a guideline only. No responsibility is assumed for the control or correction of conditions.
Page 6 of 8
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-169B Rev.2
CERTIFICATE OF THOROUGH EXAMINATION
Certificate Number: CTE-1173-061
Customer: Ocean Rig Color Code: Green
Location: Corcovado Inspection Procedure: PI-QT-011
SFI Code: 455 Client WO: 2015-09352
Date of Examination: 23/11/2015 Manufacture: Crosby
Date of Next Examination: 22/11/2016 Equipment Status: Approved
Identity No Description & Detail Of Equipment Location SWL Test Proof
Load
SHK-6
CROSBY ORIGINAL CERTIFICATE
CCI-2015111600303
SWIVEL HOOK SHUR-LOC
½’’ 13MM
GR-100 / G10
LIFTING LOCKER
STBD/FWD
15000 lbs N/A
Previously tested by the manufacturer
General Comment: NO DEFECT FOUND AT TIME OF INSPECTION
I certify on behalf of the firm, Company, association or technician named below that the items described herein were tested and thereafter examined and were found to be free from cracks, flaws or other defects
Name / Qualification: Allan Paulino Siqueira
ASNT II / IRATA
Signed / Stamp:
Date of Inspection: November 23th, 2015
Approved by:
This certification or Report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacture, seller, supplier repairer, or operator of any warranty, express or implied and Qualitech. Liability shall be limited to the acs and omissions of it's employees, agents and subcontractors. Under no circumstances shall Qualitech be liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse of or any defect in material, machinery, equipment, or other items other than defects in items actually inspected by Qualitech and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by Qualitech and which are covered by this certificate or report. The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to Qualitech personnel. The report does not purport to list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as a guideline only. No responsibility is assumed for the control or correction of conditions.
Page 7 of 8
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-169B Rev.2
CERTIFICATE OF THOROUGH EXAMINATION
Certificate Number: CTE-1173-062
Customer: Ocean Rig Color Code: Green
Location: Corcovado Inspection Procedure: PI-QT-011
SFI Code: 455 Client WO: 2015-09352
Date of Examination: 23/11/2015 Manufacture: Crosby
Date of Next Examination: 22/11/2016 Equipment Status: Approved
Identity No Description & Detail Of Equipment Location SWL Test Proof
Load
SHK-7
CROSBY ORIGINAL CERTIFICATE
CCI-2015111600303
SWIVEL HOOK SHUR-LOC
½’’ 13MM
GR-100 / G10
LIFTING LOCKER
STBD/FWD
15000 lbs N/A
Previously tested by the manufacturer
General Comment: NO DEFECT FOUND AT TIME OF INSPECTION
I certify on behalf of the firm, Company, association or technician named below that the items described herein were tested and thereafter examined and were found to be free from cracks, flaws or other defects
Name / Qualification: Allan Paulino Siqueira
ASNT II / IRATA
Signed / Stamp:
Date of Inspection: November 23th, 2015
Approved by:
This certification or Report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacture, seller, supplier repairer, or operator of any warranty, express or implied and Qualitech. Liability shall be limited to the acs and omissions of it's employees, agents and subcontractors. Under no circumstances shall Qualitech be liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse of or any defect in material, machinery, equipment, or other items other than defects in items actually inspected by Qualitech and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by Qualitech and which are covered by this certificate or report. The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to Qualitech personnel. The report does not purport to list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as a guideline only. No responsibility is assumed for the control or correction of conditions.
Page 8 of 8
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240
www.qualitechirm.com Quality for safety
RP-QT-169B Rev.2
CERTIFICATE OF THOROUGH EXAMINATION
Certificate Number: CTE-1173-063
Customer: Ocean Rig Color Code: Green
Location: Corcovado Inspection Procedure: PI-QT-011
SFI Code: 455 Client WO: 2015-09352
Date of Examination: 23/11/2015 Manufacture: Crosby
Date of Next Examination: 22/11/2016 Equipment Status: Approved
Identity No Description & Detail Of Equipment Location SWL Test Proof
Load
SHK-8
CROSBY ORIGINAL CERTIFICATE
CCI-2015111600303
SWIVEL HOOK SHUR-LOC
½’’ 13MM
GR-100 / G10
LIFTING LOCKER
STBD/FWD
15000 lbs N/A
Previously tested by the manufacturer
General Comment: NO DEFECT FOUND AT TIME OF INSPECTION
I certify on behalf of the firm, Company, association or technician named below that the items described herein were tested and thereafter examined and were found to be free from cracks, flaws or other defects
Name / Qualification: Allan Paulino Siqueira
ASNT II / IRATA
Signed / Stamp:
Date of Inspection: November 23th, 2015
Approved by:
This certification or Report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacture, seller, supplier repairer, or operator of any warranty, express or implied and Qualitech. Liability shall be limited to the acs and omissions of it's employees, agents and subcontractors. Under no circumstances shall Qualitech be liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse of or any defect in material, machinery, equipment, or other items other than defects in items actually inspected by Qualitech and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by Qualitech and which are covered by this certificate or report. The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to Qualitech personnel. The report does not purport to list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as a guideline only. No responsibility is assumed for the control or correction of conditions.
Page 1 of 1
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240 www.qualitechirm.com
Quality for safety RP-QT-117B Rev.3
PHOTOGRAPHIC INSPECTION REPORT
Client: Ocean Rig Location: Corcovado Report Number: PIR-1173-016
P.O. Nr: ORBRZ-0055-2015 WO: 1173 Reference Document: N/A
SFI Code: 503.745 Client WO: 2015-09366
Item: Derrick Sala Block.
Details: Replacement of the Retractable Lifeline 53m from the Derrick Main Well PORT/AFT.
Corrective Action: Preventive Maintenance.
OLD SALA BLOCK
NEW SALA BLOCK
Name / Qualification: Allan Paulino Siqueira
ASNT II / IRATA I
Signed / Stamp:
Date of Inspection: November 26th,2015
Approved By:
Page 1 of 1
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240 www.qualitechirm.com
Quality for safety RP-QT-117B Rev.3
PHOTOGRAPHIC INSPECTION REPORT
Client: Ocean Rig Location: Corcovado Report Number: PIR-1173-014
P.O. Nr: ORBRZ-0055-2015 WO: 1173 Reference Document: N/A
SFI Code: 721.111.031 Client WO: 2015-09346
Item: Sea Chest Vent Line Gasket.
Details: FWD Aux Machinery space Sea Chests Vent Line leak to be fixed.
Corrective Action: Preventive Maintenance.
Was performed the removal of Old Gasket and installed the New one as requested
Name / Qualification: Allan Paulino Siqueira
ASNT II / IRATA I
Signed / Stamp:
Date of Inspection: November 21th,2015
Approved By:
Page 1 of 1
Qualitech Inspeção, Reparo e Manutenção Ltda. Estrada do Engenho D’Água,1330, Box01-C, Anil, Jacarepaguá–RJ – Brasil CEP 22765-240 www.qualitechirm.com
Quality for safety RP-QT-117B Rev.3
PHOTOGRAPHIC INSPECTION REPORT
Client: Ocean Rig Location: Corcovado Report Number: PIR-1173-015
P.O. Nr: ORBRZ-0055-2015 WO: 1173 Reference Document: N/A
SFI Code: 813.500 Client WO: 2015-09369
Item: 8’’ Bellow Flexible Flange for Fire Line.
Details: Replacement of the damaged 8’’ Bellow Flexible Flange.
Corrective Action: Preventive Maintenance.
New 8’’ Bellow with Flanges fitted and also new Gaskets and Bolts
Name / Qualification: Allan Paulino Siqueira
ASNT II / IRATA I
Signed / Stamp:
Date of Inspection: November 24th,2015
Approved By:
Damaged Equipment that
was replaced
Sr. Allan Paulino Siqueira Mr. Allan Paulino Siqueira
Certificado Nº. ET - 4322 R1
Certificate Nr. ET - 4322 R1
É qualificado como Nível II no ensaio de Correntes Parasitas de acordo com os requisitos da Pratica Escrita da Qualitech PI QT 10 Rev.1 baseado na Prática Recomendada SNT-TC 1A (Ed. 2006) da ASNT.
Is qualified as Level II in Eddy Current testing according to the requirements of Qualitech
Written Practice PI QT 10 Rev. 1 based in recommended practice SNT-TC-1A (2006 edition) of ASNT.
Data da Certificação: 01 de Fevereiro 2013(IRM) Certification Date: Fevereiro 01st 2013 (IRM)
Recertificado em: Outubro de 2014 (R1) Recertificated in: October 2014 (R1)
Validade: Outubro de 2018 Validity: October 2018
Transferido para Qualitech em: Outubro de 2014
Transferred to Qualitech in: October 2014
_________________________ _________________________ Marco Antonio M. de Guido Leonardo Torres
Nível III ASNT nº. 85594 Qualitech Inspeção, Reparo e Manutenção Ltda.
Este certificado é válido por um período de cinco anos contados à partir da data acima, salvo cancelamento ou revogação em data anterior e perderá sua validade quando o nomeado deixar de ser funcionário da Qualitech Inspeção, Reparo e Manutenção Ltda.
This certificate is valid for a period of five years from the above date of signature, unless terminated or revoked at an earlier data, and it is automatically terminated when the above named ceases to be an employee of Qualitech Inspeção, Reparo e Manutenção Ltda.
Sr. Allan Paulino Siqueira Mr. Allan Paulino Siqueira
Certificado Nº. MT - 3001 R1
Certificate Nr. MT - 3001 R1
É qualificado como Nível II no ensaio de Partículas Magnéticas de acordo com os requisitos da Pratica Escrita da Qualitech PI QT 10 Rev.1 baseado na Prática Recomendada SNT-TC 1A (Ed. 2006) da ASNT.
Is qualified as Level II in Magnetic Particle testing according to the requirements of Qualitech
Written Practice PI QT 10 Rev. 1 based in recommended practice SNT-TC-1A (2006 edition) of ASNT.
Data da Certificação: 08 de Outubro 2010(IRM) Certification Date: October 08th 2010(IRM)
Recertificado em: Outubro de 2014 (R1) Recertificated in: October 2014 (R1)
Validade: Outubro de 2016 Validity: October 2016
Transferido para Qualitech em: Outubro de 2014
Transferred to Qualitech in: October 2014
_________________________ _________________________ Marco Antonio M. de Guido Leonardo Torres
Nível III ASNT nº. 85594 Qualitech Inspeção, Reparo e Manutenção Ltda.
Este certificado é válido por um período de cinco anos contados à partir da data acima, salvo cancelamento ou revogação em data anterior e perderá sua validade quando o nomeado deixar de ser funcionário da Qualitech Inspeção, Reparo e Manutenção Ltda.
This certificate is valid for a period of five years from the above date of signature, unless terminated or revoked at an earlier data, and it is automatically terminated when the above named ceases to be an employee of Qualitech Inspeção, Reparo e Manutenção Ltda.
Sr. Allan Paulino Siqueira Mr. Allan Paulino Siqueira
Certificado Nº. UT - 3267 ME
Certificate Nr. UT - 3267 R1 ME
É qualificado como Nível II no ensaio de Ultrasson / Medição de Espessura de acordo com os requisitos da Pratica Escrita da Qualitech PI QT 10 Rev.1 baseado na Prática Recomendada SNT-TC 1A (Ed. 2006) da ASNT.
Is qualified as Level II in Ultrasonic / Thickness Measure testing according to the requirements of Qualitech
Written Practice PI QT 10 Rev. 1 based in recommended practice SNT-TC-1A (2006 edition) of ASNT.
Data da Certificação: 24 de Maio 2011(IRM) Certification Date: May 24th 2010(IRM)
Recertificado em: Outubro de 2014 (R1) Recertificated in: October 2014 (R1)
Validade: Maio de 2016 Validity: May 2016
Transferido para Qualitech em: Outubro de 2014
Transferred to Qualitech in: October 2014
_________________________ _________________________ Marco Antonio M. de Guido Leonardo Torres
Nível III ASNT nº. 85594 Qualitech Inspeção, Reparo e Manutenção Ltda.
Este certificado é válido por um período de cinco anos contados à partir da data acima, salvo cancelamento ou revogação em data anterior e perderá sua validade quando o nomeado deixar de ser funcionário da Qualitech Inspeção, Reparo e Manutenção Ltda.
This certificate is valid for a period of five years from the above date of signature, unless terminated or revoked at an earlier data, and it is automatically terminated when the above named ceases to be an employee of Qualitech Inspeção, Reparo e Manutenção Ltda.
Certificamos que Allan Paulino Siqueira participou do Treinamento deAtendimento a NR-34 Item 4 - Curso básico para Trabalhos a Quente -Módulo Geral - nas instalações da QUALITECH INSPEÇÃO, REPAROE MANUTENÇÃO LTDA, no dia 30 de Junho de 2015, carga horária08h.
___________________________Leonardo Torres Martins da SilvaDiretor de OperaçõesCNPJ:17.417.147/0001-84
__________________________________Antônio Carlos Dias PereiraCREA-RJ:1999105764CNPJ:10.848.080/0001-93
RP-QT-086 Rev.0
Rio de Janeiro, 30 de Junho de 2015.Validade: 12 meses
Estudo da NR-34, Item 34.5;b) Identificação de Perigos e Análise de Riscos• Conceitos de Perigos e Riscos;• Técnicas de Identificação de Perigos e Análise de Riscos;• APP e APR - Análise Preliminar de Perigos e Análise Preliminar de Riscos. c)Permissão para Trabalho - PT; d) Limite inferior e superior de explosividade; e) Medidas de Controle no Local de Trabalho • Inspeção Preliminar• Controle de materiais combustíveis e inflamáveis• Proteção Física• Atividades no entorno• Sinalização e Isolamento do Local de Trabalho;• Inspeção Posterior para controle de fontes de igniçãof) Renovação de Ar no Local de Trabalho (Ventilação/Exaustão);g) Rede de Gases (Válvulas e Engates); h) Ergonomia;i) Doenças ocupacionais;ii) j) FISPQ
RP-QT-066 Rev.0
Certificamos que Allan Paulino Siqueira participou do Treinamento deAtendimento a NR-34 Condições e Meio Ambiente de Trabalho naIndústria de Construção e Reparação Naval nas instalações daQUALITECH INSPEÇÃO, REPARO E MANUTENÇÃO LTDA, nodia 22 de setembro de 2015, carga horária 06h.
___________________________Leonardo Torres Martins da SilvaDiretor de OperaçõesCNPJ:17.417.147/0001-84
__________________________________Antônio Carlos Dias PereiraCREA-RJ:1999105764CNPJ:10.848.080/0001-93
RP-QT-086 Rev.0
Rio de Janeiro, 22 de setembro de 2015.Validade: 12 meses
Riscos Inerentes as Atividades:− Divulgação dos Riscos Ocupacionais existentes em cada atividade e suas medidas de controle,Divulgação da Ordem de Serviço conforme NR-01.
Uso adequado de Equipamentos de Proteção Individual – EPI e Equipamento de Proteção ColetivaEPC existentes no estabelecimento:− Movimentação de Carga, equipamentos e acessórios, uso e operacionalidade.− Definição de EPI, Obrigatoriedades quanto ao uso dos mesmos conforme NR-06, Uso correto deEPI’s com exercício prático para Proteção de Cabeça, Tronco; Membros Inferiores e Superiores; Mãos;Pés; Olhos; Facial; Respiratória e Auditiva;− Guarda e higienização dos EPI´s;− Definição de EPC,Informações sobre os tipos de EPC´s existentes nas atividades da Empresa e emUnidades de Contratos e informações sobre o manuseio dos mesmos.
Condições e meio ambiente de trabalho:− Informações sobre Unidades de Contrato;− Regras de Segurança, Saúde e Meio Ambiente para as Atividades Operacionais;− Informações sobre sistemas para Identificação de Riscos e Reconhecimento de Boas Práticas de nossos clientes com exercício prático.
RP-QT-066 Rev.0
Sr. Bruno da Silveira Cerri Mr. Bruno da Silveira Cerri
Certificado Nº. MT - 3276
Certificate Nr. MT - 3276
É qualificado como Nível II no ensaio de Partículas Magnéticas de acordo com os requisitos da Pratica Escrita da Qualitech PI QT 10 Rev.0 baseado na Prática Recomendada SNT-TC 1A (Ed. 2006) da ASNT.
Is qualified as Level II in Magnetic Particle testing according to the requirements of Qualitech
Written Practice PI QT 10 Rev. 0 based in recommended practice SNT-TC-1A (2006 edition) of ASNT.
Data da Certificação: 24 de Maio de 2011 (IRM) Certification Date: May 24th 2011 (IRM)
Validade: Julho de 2018 Validity: July 2018
Transferido para Qualitech em: Julho de 2014
Transferred to Qualitech in: Julho 2014
_________________________ _________________________ Marco Antonio M. de Guido Leonardo Torres
Nível III ASNT nº. 85594 Qualitech Inspeção, Reparo e Manutenção Ltda.
Este certificado é válido por um período de cinco anos contados à partir da data acima, salvo cancelamento ou revogação em data anterior e perderá sua validade quando o nomeado deixar de ser funcionário da Qualitech Inspeção, Reparo e Manutenção Ltda.
This certificate is valid for a period of five years from the above date of signature, unless terminated or revoked at an earlier data, and it is automatically terminated when the above named ceases to be an employee of Qualitech Inspeção, Reparo e Manutenção Ltda.
Sr. Bruno da Silveira Cerri Mr. Bruno da Silveira Cerri
Certificado Nº. UT - 3269
Certificate Nr. UT - 3269
É qualificado como Nível II no ensaio de Ultrassom / Medição de Espessura de acordo com os requisitos da Pratica Escrita da Qualitech PI QT 10 Rev.0 baseado na Prática Recomendada SNT-TC 1A (Ed. 2006) da ASNT.
Is qualified as Level II in Ultrasonic / Thickness Measure testing according to the requirements of Qualitech
Written Practice PI QT 10 Rev. 0 based in recommended practice SNT-TC-1A (2006 edition) of ASNT.
Data da Certificação: 24 de Maio de 2011 (IRM) Certification Date: May 24th 2011 (IRM)
Validade: Maio de 2016 Validity: May 2016
Transferido para Qualitech em: Julho de 2014
Transferred to Qualitech in: Julho 2014
_________________________ _________________________ Marco Antonio M. de Guido Leonardo Torres
Nível III ASNT nº. 85594 Qualitech Inspeção, Reparo e Manutenção Ltda.
Este certificado é válido por um período de cinco anos contados à partir da data acima, salvo cancelamento ou revogação em data anterior e perderá sua validade quando o nomeado deixar de ser funcionário da Qualitech Inspeção, Reparo e Manutenção Ltda.
This certificate is valid for a period of five years from the above date of signature, unless terminated or revoked at an earlier data, and it is automatically terminated when the above named ceases to be an employee of Qualitech Inspeção, Reparo e Manutenção Ltda.
Certificamos que Bruno da Silveira Cerri participou do Treinamento deAtendimento a NR-34 Condições e Meio Ambiente de Trabalho naIndústria de Construção e Reparação Naval nas instalações daQUALITECH INSPEÇÃO, REPARO E MANUTENÇÃO LTDA, nodia 02 de Julho de 2015, carga horária 06h.
___________________________Leonardo Torres Martins da SilvaDiretor de OperaçõesCNPJ:17.417.147/0001-84
__________________________________Antônio Carlos Dias PereiraCREA-RJ:1999105764CNPJ:10.848.080/0001-93
RP-QT-086 Rev.0
Rio de Janeiro, 02 de Julho de 2015.Validade: 12 meses
Riscos Inerentes as Atividades:− Divulgação dos Riscos Ocupacionais existentes em cada atividade e suas medidas de controle,Divulgação da Ordem de Serviço conforme NR-01.
Uso adequado de Equipamentos de Proteção Individual – EPI e Equipamento de Proteção ColetivaEPC existentes no estabelecimento:− Movimentação de Carga, equipamentos e acessórios, uso e operacionalidade.− Definição de EPI, Obrigatoriedades quanto ao uso dos mesmos conforme NR-06, Uso correto deEPI’s com exercício prático para Proteção de Cabeça, Tronco; Membros Inferiores e Superiores; Mãos;Pés; Olhos; Facial; Respiratória e Auditiva;− Guarda e higienização dos EPI´s;− Definição de EPC,Informações sobre os tipos de EPC´s existentes nas atividades da Empresa e emUnidades de Contratos e informações sobre o manuseio dos mesmos.
Condições e meio ambiente de trabalho:− Informações sobre Unidades de Contrato;− Regras de Segurança, Saúde e Meio Ambiente para as Atividades Operacionais;− Informações sobre sistemas para Identificação de Riscos e Reconhecimento de Boas Práticas de nossos clientes com exercício prático.
RP-QT-066 Rev.0
Certificamos que Rennan Gaspar Mendes participou do Treinamentode Atendimento a NR-34 Condições e Meio Ambiente de Trabalho naIndústria de Construção e Reparação Naval nas instalações daQUALITECH INSPEÇÃO, REPARO E MANUTENÇÃO LTDA, nodia 27de Março de 2015, carga horária 06h.
___________________________Leonardo Torres Martins da SilvaDiretor de OperaçõesCNPJ:17.417.147/0001-84
__________________________________Antônio Carlos Dias PereiraCREA-RJ:1999105764CNPJ:10.848.080/0001-93
RP-QT-086 Rev.0
Rio de Janeiro, 27 de Março de 2015.Validade: 12 meses
Riscos Inerentes as Atividades:− Divulgação dos Riscos Ocupacionais existentes em cada atividade e suas medidas de controle,Divulgação da Ordem de Serviço conforme NR-01.
Uso adequado de Equipamentos de Proteção Individual – EPI e Equipamento de Proteção ColetivaEPC existentes no estabelecimento:− Movimentação de Carga, equipamentos e acessórios, uso e operacionalidade.− Definição de EPI, Obrigatoriedades quanto ao uso dos mesmos conforme NR-06, Uso correto deEPI’s com exercício prático para Proteção de Cabeça, Tronco; Membros Inferiores e Superiores; Mãos;Pés; Olhos; Facial; Respiratória e Auditiva;− Guarda e higienização dos EPI´s;− Definição de EPC,Informações sobre os tipos de EPC´s existentes nas atividades da Empresa e emUnidades de Contratos e informações sobre o manuseio dos mesmos.
Condições e meio ambiente de trabalho:− Informações sobre Unidades de Contrato;− Regras de Segurança, Saúde e Meio Ambiente para as Atividades Operacionais;− Informações sobre sistemas para Identificação de Riscos e Reconhecimento de Boas Práticas de nossos clientes com exercício prático.
RP-QT-066 Rev.0