Cable Management System

44
8/9/2019 Cable Management System http://slidepdf.com/reader/full/cable-management-system 1/44

Transcript of Cable Management System

Page 1: Cable Management System

8/9/2019 Cable Management System

http://slidepdf.com/reader/full/cable-management-system 1/44

Page 2: Cable Management System

8/9/2019 Cable Management System

http://slidepdf.com/reader/full/cable-management-system 2/44

 Tel: +971 (2) 6448330Fax: +971 (2) 6448322

P.O. Box: 41558Abu Dhabi

Tel: +971 (4) 8858036Fax: +971 (4) 8858658

P.O. Box: 86029Dubai

 Tel: +971 (3) 7224768Fax: +971 (3) 7224769

P.O. Box: 99155Al Ain

 Tel: +971 (7) 2282332Fax: +971 (7) 2282232

P.O. Box: 33239Ras Al khaimah

CONTENTSTable of 

Technical Metal Industrial Co. L.L.C.Tel: +971 (2) 5502025 Fax: +971 (2) 5502024 P.O. Box: 41558 Abu Dhabi U.A.E.

E-mail: [email protected] Web: www.tmi-co.com

About Cable Management System i

Technical Specication X

Metal Framing Systems 43

1Cable Tray System Overview

4Cable Tray Staight System

6Cable Tray Fittings

16Cable Ladder Fittings

27Cable Trunking Fittings

11Cable Ladder System Overview

14Cable Ladder Straight Overview

24Cable Trunking Straight

21Cable Trunking System Overview

56Cable Tray acessories & Connectors

60Cable Ladder acessories & Connectors

63Cable Trunking acessories & Connectors

65Cable Basket acessories & Connectors

70Support System Fasteners

47Post Bases & I- Beam Support

49Struts Fittings

55Cable Tray Covers

59Cable Ladder Covers

65Cable Basket Covers

33Cable Basket System Overview

36Cable Basket Straight

37Cable Cable Basket Fittings

Page 3: Cable Management System

8/9/2019 Cable Management System

http://slidepdf.com/reader/full/cable-management-system 3/44

i

About Cable Management System

TMI Cable Management System offers you a simple, inexpensive method of routing and supporting all types

of light to heavy weight cables. Ideal for all types of commercial, industrial and government applications.

Available in different widths, heights, and lengths, complete line of ttings and accessories provide exibility

to meet installation requirements, also available in Hot Dip Galvanized Steel, Aluminum or Stainless Steel built

to NEMA VE-1, BS and BS EN standards.

Application

Cable Trays quickly proved their worth as a safe, dependable and cost-effective solution to routing and

supporting cables Early on the need for standardization was recognized and NEMA VE-1 Metal Cable Tray

standard was published in the early 1960s. NEMA VE-1 and British Stanards has been updated many times; 

TMI Cable Trays conform to all NEMA VE-1, British Standard, IEC and ASTM standards referring to denitions

of Cable Trays, ttings, connectors and accessories.

Cable Management Systems including Cable Trays and Cable Ladders came of age in the mid-forties. They were

used to support the new armored shielded power cables that were permitted outside the conduit environment.

Utilities and industrial companies initiated the use of mesh and solid trough-style trays for supporting power

and control cable.

Cable Tray have long been a popular choice for effectively supporting and routing cable in the commercial

environment, and faster installation continues to be the most signicant factor inuencing the enhancement of

Cable Tray products.

Fixing

Aluminum Cable Trays are fabricated from structural grade “copper free” (marine grade) Aluminum

extrusions. Aluminum’s excellent corrosion resistance is due to its ability to form an aluminum oxide

lm that when scratched reforms the original protective lm. Aluminum has excellent resistance to

“weathering” in most outdoor applications. Aluminum Cable Tray has excellent corrosion resistance

in many chemical environments. Typically, Aluminum Cable Trays can perform indenitely, with little

or no degradation over time, making it ideal for many chemical and marine environments.

Aluminum

The resistance to chemicals, indoors and outdoors, can best be determined by tests conducted by the

user with exposure to the specic conditions for which it is intended. For further information, contact

Technical Metal Industrial Co. LLC (TMI).

SteelSteel Cable Trays are fabricated from continuous roll-formed structural quality steel. By roll-forming

steel, the mechanical properties are increased allowing the used of a lighter gauge steel to carry the

required load. This reduces the dead weight that must be carried by the supports and the installers.

Using structural quality steel, Technical Metal Industrial Co. LLC (TMI) assures that the material will

meet the minimum yield and tensile strengths of applicable ASTM, NEMA and British Standards. The

corrosion resistance of steel varies widely with coating and alloy.

Stainless Steel

Stainless Steel Cable Trays are fabricated from continuous roll-formed AISI Type 304, AISI Type 316

and AISI Type 316L Stainless Steel which belongs to the group called austenitic Stainless Steels. Like

carbon steel, they exhibit increased strength when cold worked by roll-forming or bending.

Several important conditions could make the use of Stainless Steel imperative. These include long

term maintenance cost, corrosion resistance, appearance and locations where product contamination

is undesirable. Stainless Steel exhibits stable structural properties such as yield strength and high creepstrength at elevated temperatures.

Technical Metal Industrial Co. LLC (TMI) Stainless Steel Cable Trays are welded using Stainless Steel

welding wire to ensure each weldment exhibits the same corrosion resistance characteristic as the base

metal. Localized staining in the weld area or heat affected zone may occur in severe environments.

Specialized shielding gases and low carbon materials are used to minimize carbon contamination

during welding and reduce staining and stress corrosion. Specify passivity after fabrication as per

ASTM A380 to minimize staining, improve aesthetics and further improve corrosion resistance.

Zinc protects steel in two ways. First it protects the steel as a coating and second as a sacricial anode

to repair bare areas such as cut edges, scratches, and gouges. The corrosion protection of zinc is

directly related to its thickness and the environment. This means a 0.2 mil coating will last twice aslong as a 0.1 mil coating in the same environment.

Zinc Coatings

Electro Galvanized ZincElecrogalvanized Zinc (also known as Zinc Plated or electroplated) is the process by which a coating

of zinc is deposited on the steel by electro-deposition from a bath of zinc salts.

A rating of SC3, TMI Standard, provides a minimum zinc coating thickness of 0.5 mils (excluding

threaded rod, which is SC1 = 0.2mils)

II

Page 4: Cable Management System

8/9/2019 Cable Management System

http://slidepdf.com/reader/full/cable-management-system 4/44

Chromium / ZincChromium / Zinc is a corrosion resistant composition, which was developed to protect fastener and

small bulk items for automotive use. The coating applications have since been extended to larger parts

and other markets.

Chromium/Zinc composition is an aqueous coating dispersion containing chromium, proprietary

organic, and zinc ake.

This nish provides 1000 hours protection in salt spray testing as per ASTM B 117, exceeding NEMA

VE-1 requirements by 300%.

When exposed to air and moisture, zinc forms a tough, adherent, protective lm consisting of a mixture

of zinc oxides, hydroxides, and carbonates.

This lm is in itself a barrier coating which slows subsequent corrosive attack on the zinc. This coating

is usually recommended for indoor use in relatively dry areas, as it provides ninety six hours protection

in salt spray testing per ASTM B117.

Pre-Galvanized Zinc(Mill Galvanized, Hot Dip Mill Galvanized or Continuous Hot Dip Galvanized)

Pre-Galvanized steel is produced by coating coils of sheet steel with zinc by continuously rolling

the material through molten zinc at the mills. This is also known as mill galvanized or hot dip mil

galvanized. These coils are then slit to size and fabricated by roll forming, shearing, punching, or

forming to produce Technical Metal Industrial Co. LLC (TMI) pre-galvanized Cable Tray products(GI),

or HDGBF ( Hot Dip Galavanized Before Fabrication)

The G90 specication call for a coating of 90 ounces of zinc per square foot of steel. This results in a

coating of 45 ounces per square foot on each side of the sheet. This is important when comparing this

nish to hot dip galvanized after fabrication.

During fabrication, cut edge and welded areas are not normally zinc coated; however, the zinc near

the uncoated metal becomes a sacricial anode to protect the bare areas after short period of time.

To further insure a quality product, Technical Metal Industrial Co. LLC (TMI) welds all pre-galvanized

Cable Trays with a silicon bronze welding wire allowing only a small heat affected zone to be exposed.

This small area quickly repairs itself by the same process as cut edges.

 Hot Dip Galvanized After Fabrication

(Hot Dip Galvanized or Batch Hot Dip Galvanized)

Hot Dip Galvanized after Fabrication Cable Tray products are fabricated from steel and then completely

immersed in a bath of molten zinc. A metallic bond occurs resulting in a zinc coating that completely

coats all surfaces, including edges and welds.

Another advantage of this method is coating thickness. Cable Trays Hot Dip Galvanized After

Fabrication (HDGAF) have a minimum thickness in accordance to ASTM A123 and BS 1461 (updated

standard of BS 729).

The zinc thickness is controlled by several factors 2 of which are the amount of time each part is

immersed in the molten zinc bath, as well as, the speed of dipping and removal.

The layer of zinc which bonds to steel provides a dual p rotection against corrosion. It protects rst as

an overall barrier coating. If this coating happens to be scratched or gouged, zinc’s secondary defense

is called upon to protect the steel by galvanic action.

Hot Dip Galvanized after Fabrication is recommended for prolonged outdoor exposure and will protect

steel for many years in most outdoor environments and in many aggressive industrial environments.

 

Technical Metal Industrial (TMI) follows the steps below for its Hot Dipped Galvanized Process which

is in compliance with ASTM A123 and BS 1461(updated version of BS 729): 

1. All materials received for Hot Dip Galvanizing are checked for adequacy (For Galvanizing) and

holes drilled in conned spaces as per the International Standards BS 1461, ASTM 123 and 153 to en-

sure the immersion of the structure in the Zinc Bath and to allow the Zinc to reach the internal surfaces

of the Steel. The material is then forwarded to the appropriate cleaning equipment to remove dirt, rust

and paint.

2. The cleaned steel is delivered for Chemical Pre-treatment starting with the degreasing and pickling

operation where it is immersed in one of the six tanks of Hydrochloric Acid (10-15%) solution for a

minimum period of 20 Minutes.

3. After pickling, the steel is rinsed in one of the two fresh water tanks then immersed in running water

tank to ensure the complete removal of the residual acid and iron salts from the operation.

4. The Steel is then lifted to the uxing tank where it is immersed for 3-5 in an aqueous ux solution

of Zinc Ammonium Chloride ( Zn NH4 Cl3), 40% Solution, i.e 28 Degrees Be, to ensure full chemical

bonding between Steel and Zinc during the Galvanizing process.

III IV

Page 5: Cable Management System

8/9/2019 Cable Management System

http://slidepdf.com/reader/full/cable-management-system 5/44

 Atmospheric Corrosion

Atmospheric corrosion occurs when metal is exposed to airborne liquids, solid or gases. Some sources

of atmospheric corrosion are moisture, salt, dirt and sulphuric acid. This form of corrosion is typically

worse outdoors, especially near marine environments.

 Chemical CorrosionChemical corrosion takes place when metal comes in direct contact with corrosive media. Some

factors which affect the severity of chemical corrosion include: chemical concentration level, duration

of contact, frequency of washing and operating temperature.

Storage Corrosion

Wet storage stain (White Rust) is caused by the entrapment of moisture between surfaces of closely

packed and poorly ventilated material for an extended period. Wet storage stain is usually supercial,

having no affect on the properties of the metal.

Light staining normally disappears with weathering. Medium to heavy build up should be removed in

order to allow the formation of normal protective lm. Proper handling and storage will help to assure

stain-fee material. If product arrives wet, it should be unpacked and dried before storage. Dry materialshould be stored in a well ventilated low moisture” environment to avoid condensation formation.

Outdoor storage is undesirable, and should be avoided whenever possible.

Galvanic Corrosion

Galvanic Corrosion occurs when two or more dissimilar metals are in contacts in the presence of an

electrolyte (ie. Moisture). An electrolyte cell is created and the metals form an anode or a cathode

depending on their relative position on the Galvanic Series Table. The anodic material will be the

one to corrode. Whether a material is anodic depends on the relative position of the material. For

example: If zinc and steel are in contact, the zinc acts as the anode and will corrode; the steel acts as

the cathode, and will be protected. If steel and copper are in contact, the steel is now the anode and

will corrode.

The rate at which galvanic corrosion occurs depends on several factors:

The amount and concentration o f electrolyte present in an indoor, d ry environment will have little or

no galvanic corrosion compared to a wet atmosphere.

The relative size of the materials: A small amount of anodic material in contact with a large1.

cathodic material will result in greater corrosion. Likewise, a large anode in contact with a small

cathode will decrease the rate of attack.

The relative position on the Galvanic Series Table: The further apart in the Galvanic Series2.

Table, the greater the potential for corrosion of the anodic material.

Painting Cable Tray

It is typically more cost effective to use an Aluminum or Pre-Galvanized Steel Cable Tray and paint it

after installation, along with the other un-painted building components.

 

Painted Cable Tray is often used in “open ceiling” applications where all the overhead equipment and

structure is painted the same color. In this type of application, additional painting is often necessaryin the eld, after installation, to ensure all of the supporting components, such as hanger rods, clamps

and attaching harware have been painted uniformly. Pre-painted Cable Tray interferes with common

grounding practices, requiring the paint to be removed at splice locations, and / or the addition of

bonding jumpers that were otherwise unnecessary. This additional eld modication not only increases

the installation cost, but causes potential damage to the special painted nish.

Consult painting contractor for proper surface preparation.

Special Paint

Technical Metal Industrial Co. L.L.C. (TMI) Cable Tray and support can be painted or primed to meet

the customer’s requirements. Technical Metal Industrial Co. L.L.C. (TMI) has several colors available,

consult the factory.

If a non-standard color is required the following information needs to be specied.

Type of material preparation (primer, etc.)1.

Type of paint manufacturer and paint number or type of paint with chip.2.

Dry lm thickness.3.

Corrosion

 All metal surfaces are affected by corrosion. Depending on the physical properties of the metal and the

environment to which it is exposed, chemical or Electromechnical corrosion may occur.

5. After uxing the steel is dried and preheated with hot dry air in double heating oven.

6. The Steel is now ready for galvanizing and is dipped in the galvanizing gath holding more than 290

Tonnes of 99.995% SHG ZINC (LME registered) at temperatures of 445-455 Degrees Celsius. Mini-

mum dipping time is 3 minutes for full chemical bonding between Zinc and Steel.

7. Prior to immersion of steel in the galvanizing bath, The molten Zinc surface is “Skimmed” clean of

Zinc Ash to avoid residual coming in contact with Steel during dipping, The same process is repeatedbefore removing the steel from the Galvanizing bath.

8. After Hot Dip Galvanizing and depending on the thickness of steel, the Steel is quenched in water

before nal inspection. Pre-delivery checks are conducted by QC Engineer on the surface and general

nish of the galvanized surface. Instructions are given for cleaning (Zinc Residuals) and rectication

where necessary.

V VI

Page 6: Cable Management System

8/9/2019 Cable Management System

http://slidepdf.com/reader/full/cable-management-system 6/44

   M  o  r  e   A

  n  o   d   i  c

Anodic EndMagnesium

Magnesium Alloys

Zinc

Beryllium

Aluminum- Zinc Alloy (7000 series)

Aluminum (1000 series)

Aluminum – Magnesium- Silicon Alloys (6000 series)

Cadmium

Aluminum- Copper Alloys (2000 series)

Cast Iron, Wrought Iron, Mild Steel

Austenitic Nickel Cast Iron

Type 410 Stainless Steel (active)

Type 316 Stainless Steel (active)

Type 304 Stainless Steel (active)

 Naval Brass, Yellow Brass, Red Brass

Tin

Copper 

Lead – Tin Solders

Admiralty Brass, Aluminum Brass

Manganese Bronze

Silicon BronzeTin Bronze

Type 410 Stainless Steel (passive)

 Nickel- Silver 

Copper Nickel Alloys

Lead

 Nickel – Aluminum Bronze

Silver Solder 

 Nickel 200

Silver 

Type 316 Stainless Steel (passive)

Type 304 Stainless Steel (passive)

Incoloy 825

Hastelloy B

Titanium

Hastelloy C

PlatinumGraphite

Cathodic End

Galvanic Series in Sea Water

R = Recommended

F = May be used under some conditions

NR = Not Recommended

-- = Information not available

The Corrosion data given in this table is for general comparison only. (Reference Corrosion Resistance Tables).

The presence of contaminates in chemical environments can greatly affect the corrosion rate of any material.

Technical Metal Industrial Co. LLC (TMI) strongly suggest that eld ser vice tests or simulated laboratory tests using actual

environmental conditions be conducted in order to determine the proper materials and nishes to be selected.

VII VIII

Page 7: Cable Management System

8/9/2019 Cable Management System

http://slidepdf.com/reader/full/cable-management-system 7/44

Manufacturing Standards

Raw Material Standards

Technical Specification

R = Recommended

F = May be used under some conditions

NR = Not Recommended

-- = Information not available

The Corrosion data given in this table is for general comparison only. (Reference Corrosion Resistance Tables).

The presence of contaminates in chemical environments can greatly affect the corrosion rate of any material.

Technical Metal Industrial Co. LLC (TMI) strongly suggest that eld service tests or simulated laboratory tests using actual

environmental conditions be conducted in order to determine the proper materials and nishes to be selected.

Cable Tray System Nema VE 1

BS / IEC 61537

Cable Ladder System Nema VE 1

BS / IEC 61537

Cable Trunking System BS 50085

Cable Basket System

Galvanized Steel BS EN 10346:2009 ( formerly BS EN 10142:1991, formely BS

4678) coating type: Z120, Z180 & Z275ASTM A 653/A653M

BS EN 10088-2:2005 (which was direct equivalent to formerly

BS 1449:Part 2:1983 in Grade 304 2B FINISH)

ASTM A240/A240M in Grade 304 2B FINISH

Stainless Steel

Aluminum ASTM B 209 M

Mild Steel Mild Steel: BS EN 10149-3

As per manufacturer standard.Epoxy Coating

BS 6497:1984Powder Coating to

Hot dipped Galvanizing

(After fabrication) to

BS EN ISO 1461:1999 (formerly BS 729)

ASTM A123/A123 M , A 153/A153 M

IX X

Corrosion Guide Cable Tray Material 

Chemical  Stainless Type 316Stainless Type 304 Aluminum 

Hot Warm Cold Hot Warm Cold Hot Warm Cold R R 

R --

R  

R R 

--R 

R  

R R 

R R 

R  

FR 

F--

R  

R R 

--R 

R  

R R 

R R 

R  

 NR  NR 

 NR R 

-- 

F NR 

 NR R 

-- 

R  NR 

 NR R 

R  

Lactic Acid 10%Lead Acetate 5%

Magnesium Chloride 1%Magnesium Hydroxide

Magnesium Nitrate 5%

--R R R R  

--R R R R  

R R R R R  

--R F

 NR R  

--R R 

 NR R  

R R R 

 NR R  

 NR  NR 

F NR 

R  

 NR  NR 

R FR  

 NR  NR 

R R R  

 Nickel Chloride Nitric Acid 15%Oleic AcidOxalic Acid 10%Phenol CP

 NR R R R R  

FR R R R  

R R R R R  

R --R R R  

R R R R R  

R R R R R  

 NR  NR 

--R R  

 NR FFR R  

 NR R FR R  

Phosphoric Acid 50%Potassium Bromide 100%Potassium Carbonate 100%Potassium Choride5%Potassium Dichromate

R R 

R R R  

R R 

R R R  

R R 

R R R  

R R 

R R R  

R R 

R R R  

R R 

R R R  

 NR R 

R R F 

 NR R 

R R F 

 NR R 

R R R  

Potassium Hydroxide 50%Potassium Nitrate 50%

Potassium Sulfate 5%Propyl AlcoholSodium Acetate 20%

R R R R  

R R R R  

R R R R  

R R R R  

R R R R  

R R R R  

F

FF

 NR  NR  

F

FF

 NR  NR  

R R R 

 NR  

Sodium Bisulfate 10%

Sodium BorateSodium Carbonate 18%Sodium Chloride 5%Sodium Hydroxide 50%

--R R 

R R  

--R R 

R R  

R R R 

R R  

--R R 

R R  

--R R 

R R  

FR R 

R R  

FR R 

FR  

FR R 

R R  

R R R 

R R  

Sodium Hypochlorite 5%Sodium Nitrate 100%Sodium Nitrite 100%

Sodium Sulfate 100%Sodium Thiosulfate

R --

 NR  NR  NR  

R --

 NR  NR  NR  

R R 

 NR  NR  NR  

R  NR  NR  NR  NR  

R  NR  NR  NR  NR  

R F

 NR  NR  NR  

R --

 NR  NR  NR  

R  NR  NR  NR  NR  

R  NR  NR  NR  NR  

Sulfur Dioxide (Dry)Sulfuric Acid 5%Sulfuric Acid 10%Sulfuric Acid 50%Sulfuric Acid 75-98%

FR R R R  

R R R R R  

R R R R R  

--R R R 

 NR  

--R R R F 

R R R R R  

-- NR  NR 

F NR  

 NR  NR  NR 

FR  

 NR  NR 

FFF 

Sulfuric Acid 98-100%Tannic Acid 10 & 50%Tartaric Acid 10 & 50%Vinegar Zinc Chloride 5 & 20%

R R  

R R  

R R  

R R  

R R  

R R  

 NR  NR  

 NR  NR  

FF 

Zinc NitrateZinc Sulfate

Page 8: Cable Management System

8/9/2019 Cable Management System

http://slidepdf.com/reader/full/cable-management-system 8/44

Cable Tray System Overview

1 2

External Riser

Straight Reducer

Tee Horizontal

Cross Horizontal

Internal Riser

Cable Tray Straight

Bend 450

Bend 900

Page 9: Cable Management System

8/9/2019 Cable Management System

http://slidepdf.com/reader/full/cable-management-system 9/443

Cable Tray Straight - Ordering Guide (CT)

CT-HD-I-300-50-2-3000

Material Type•Cable Tray

Finishing

• HDG

• GI

• AL

• SS4

• SS6

• SS6L

C.T TYPE

• Inside Flange (SI)

• Outside Flange (SO)

• Plain Type(SP)

• 900 Outside Type(SN)

Length of Tray

Steel Thickness

Side Height

Width

Outside 900 Edge Type

Remarks

* Thickness is minimum recommended as per TMI manufacturing standard.

* Heights available are standard, other heights are available as special request.

* Standard Couplers size is 180mm x side height of Tray.

* Standard Hardware M6 Bolts for Cable Tray with M6 Nuts and Washer.

* Cable Tray Length is TMI manufacturing standard, other Lengths can be provided upon request.

* Length available are standard, other length (6000 mm) are available as special request.

Plain Type

Remarks

* Thickness is minimum recommended as per TMI manufacturing standard.

* Heights available are standard, other heights are available as special request.

* Standard Couplers size is 180mm x side height of Tray.

* Standard Hardware M6 Bolts for Cable Tray with M6 Nuts and Washer.

* Cable Tray Length is TMI manufacturing standard, other Lengths can be provided upon request.

* Length available are standard, other length (6000 mm) are available as special request.

1.0/1.2/1.5/2.0

1.0/1.2/1.5/2.0

1.0/1.2/1.5/2.0

1.0/1.2/1.5/2.0

1.0/1.2/1.5/2.0

1.2/1.5/2.0

1.2/1.5/2.01.2/1.5/2.0

1.5/2.0

1.5/2.0

1.5/2.0

1.5/2.0

2.00

2.00

2.00

2.00

2.00

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

Steel Type Tray Type Height mm Thickness mm Length mm PerformanceWidth mm

50 / 25

75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

2440/3000

2440/3000

2440/3000

2440/3000

2440/3000

2440/3000

2440/3000

2440/3000

2440/3000

2440/3000

2440/3000

2440/3000

2440/3000

2440/3000

2440/3000

2440/3000

1200

    L   i  g   h   t   D  u   t  y   i  s   1 .   0

   /   1 .   2  m  m

    T   h   i  c   k  n  e  s  s

    M  e   d   i  u  m    D

  u   t  y   i  s   1 .   5  m  m    T   h   i  c   k  n  e  s  s

    H  e  a  v  y   D  u   t  y   i  s   2 .   0

   /   2 .   5  m  m

    T   h   i  c   k  n  e  s  s

50

75

100

150

200

225

250

300

400

450

500

600

750

800

900

1050

1200

 SP

 SP

 SP

 SP

 SP

 SP

 SP

 SP

 SP

 SP

 SP

 SP

 SP

 SP

 SP

 SP

 SP

   S   L   O   T   2   0  x   7

   L   E   N   G   T   H

WIDTH

THICKNESS

HEIGHT

4

Cable Trays Straight

1.0/1.2/1.5/2.0

1.0/1.2/1.5/2.0

1.0/1.2/1.5/2.0

1.0/1.2/1.5/2.0

1.2/1.5/2.0

1.2/1.5/2.0

1.2/1.5/2.0

1.5/2.0

1.5/2.0

1.5/2.0

1.5/2.0

2.00

2.00

2.00

2.00

2.00

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

Steel Type Tray Type Height mm Thickness mm Length mm PerformanceWidth mm

75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

2440/3000

2440/3000

2440/3000

2440/3000

2440/3000

2440/3000

2440/3000

2440/3000

2440/3000

2440/3000

2440/3000

2440/3000

2440/3000

2440/3000

2440/3000

1200

75

100

150

200

225

250

300

400

450

500

600

750

800

900

1050

1200

SO

SO

SO

SO

SO

SO

SO

SO

SO

SO

SO

SO

SO

SO

SO

SO

    L   i  g   h   t   D  u   t  y   i  s   1 .   0

   /   1 .   2  m  m    T

   h   i  c   k  n  e  s  s

    M  e   d   i  u  m    D

  u   t  y   i  s   1 .   5  m  m    T

   h   i  c   k  n  e  s  s

    H

  e  a  v  y   D  u   t  y   i  s   2 .   0

   /   2 .   5  m  m    T

   h   i  c   k  n  e  s  s

   S   L   O   T   2   0  x   7

   L   E   N   G   T   H

WIDTH

THICKNESS

HEIGHT

Cable Tray Fittings - Ordering Guide (CT)

Finishing • HDG• GI• AL• SS4• SS6• SS6L

Material Type •Cable Tray

CT-HD-IR-300-50-2-RS

Fittings • Internal Riser (IR)• Cross Horizontal (CH)• Tee Horizontal (TH)• Bend 900 (B90)• Bend 450 (B45)• Reducer Straight (RS)• Reducer left (RL)• Reducer Right (RR)• Internal Riser (IR)• External Riser (ER)• Unequal Tee (UT)

Radius/Standard...etc

Side Height

Width

Steel Thickness

Page 10: Cable Management System

8/9/2019 Cable Management System

http://slidepdf.com/reader/full/cable-management-system 10/44

Inside Flange Type

Remarks

* Thickness is minimum recommended as per TMI manufacturing standard.

* Heights available are standard, other heights are available as special request.

* Standard Couplers size is 180mm x side height of Tray.

* Standard Hardware M6 Bolts for Cable Tray with M6 Nuts and Washer.

* Cable Tray Length is TMI manufacturing standard, other Lengths can be provided upon request.

* Length available are standard, other length (6000 mm) are available as special request.

Outside Flange Type

Remarks

* Thickness is minimum recommended as per TMI manufacturing standard.

* Heights available are standard, other heights are available as special request.

* Standard Couplers size is 180mm x side height of Tray.

* Standard Hardware M6 Bolts for Cable Tray with M6 Nuts and Washer.

* Cable Tray Length is TMI  manufacturing standard, other Lengths can be provided upon request.

* Length available are standard, other length (6000 mm) are available as special request.

   S   L   O   T   2   0  x   7

   L   E   N   G   T   H

WIDTH

THICKNESS

HEIGHT

   S   L   O   T   2   0  x   7

   L   E   N   G   T   H

WIDTH

THICKNESS

HEIGHT

5

    L   i  g   h   t   D  u   t  y   i  s   1 .   0

   /   1 .   2  m  m    T

   h   i  c   k  n  e  s  s

    M  e   d   i  u  m    D

  u   t  y   i  s

   1 .   5  m  m    T

   h   i  c   k  n  e  s  s

    H  e  a  v  y   D  u   t  y   i  s   2 .   0

   /   2 .   5  m  m    T

   h   i  c   k  n  e  s  s

Cable Trays Fittings

1.0/1.2/1.5/2.0

1.0/1.2/1.5/2.0

1.0/1.2/1.5/2.0

1.0/1.2/1.5/2.0

1.0/1.2/1.5/2.0

1.2/1.5/2.0

1.2/1.5/2.0

1.2/1.5/2.0

1.5/2.0

1.5/2.0

1.5/2.0

1.5/2.0

2.00

2.00

2.00

2.00

2.00

Cross Horizontal

Remarks

* Thickness is minimum recommended as per TMI manufacturing standard.

* Heights available are standard, other heights are available as special request.

* Standard Couplers size is 180mm x side height of Tray. ( Reference ________ page____ 

* Standard Hardware M6 Bolts for Cable Tray with M6 Nuts and Washer. Ref._____

* Model represents the inside ange type. Other anges available upon request as per below.

* Equal cross A=B=C=D=Width.

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

Steel Type AccessoryTray Type Thickness mm PerformanceHeightmmWidth mm

50 / 25

75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/

75 /

50 /

25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

50

75

100

150

200

225

250

300

400

450

500

600

750

800

900

1050

1200

SI

SI

SI

SI

SI

SI

SI

SI

SI

SI

SI

SI

SI

SI

SI

SI

SI

CH

CH

CH

CH

CH

CH

CHCH

CH

CH

CH

CH

CH

CH

CH

CH

CH

Outside Flange (SO) Inside Flange (SI)Outside 900 (SN) Plain (SP)

SLOT 20x7

WIDTH

THICKNESS

HEIGHT

    L   i  g   h   t   D  u   t  y   i  s   1 .   0

   /   1 .   2  m  m

    T   h   i  c   k  n  e  s  s

    M  e   d   i  u  m    D

  u   t  y   i  s   1 .   5  m  m

    T   h   i  c   k  n  e  s  s

    H  e  a  v  y   D  u   t  y   i  s   2 .   0

   /   2 .   5  m  m    T

   h   i  c   k  n  e  s  s

* Unequal cross A,B,C,D will be as per specication.

A

D

C

B

6

1.0/1.2/1.5/2.0

1.0/1.2/1.5/2.0

1.0/1.2/1.5/2.0

1.0/1.2/1.5/2.0

1.2/1.5/2.0

1.2/1.5/2.0

1.2/1.5/2.0

1.5/2.0

1.5/2.0

1.5/2.0

1.5/2.0

2.00

2.00

2.00

2.00

2.00

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

Steel Type Tray Type Height mm Thickness mm Length mm PerformanceWidth mm

75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

2440/3000

2440/3000

2440/3000

2440/3000

2440/3000

2440/3000

2440/3000

2440/3000

2440/3000

2440/3000

2440/3000

2440/3000

2440/3000

2440/3000

2440/3000

1200

75

100

150

200

225

250

300

400

450

500

600

750

800

900

1050

1200

SI

SI

SI

SI

SI

SI

SI

SI

SI

SI

SI

SI

SI

SI

SI

SI

1.0/1.2/1.5/2.0

1.0/1.2/1.5/2.0

1.0/1.2/1.5/2.0

1.0/1.2/1.5/2.0

1.2/1.5/2.0

1.2/1.5/2.0

1.2/1.5/2.0

1.5/2.0

1.5/2.0

1.5/2.0

1.5/2.0

2.00

2.00

2.00

2.00

2.00

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6LHD/GI/AL/SS4/SS6/SS6L

Steel Type Tray Type Height mm Thickness mm Length mm PerformanceWidth mm

75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25100/ 75 /50 / 25

2440/3000

2440/3000

2440/3000

2440/3000

2440/3000

2440/3000

2440/3000

2440/3000

2440/3000

2440/3000

2440/3000

2440/3000

2440/3000

2440/3000

2440/30001200

75

100

150

200

225

250

300

400

450

500

600

750

800

900

10501200

SN

SN

SN

SN

SN

SN

SN

SN

SN

SN

SN

SN

SN

SN

SNSN

    L   i  g   h   t   D  u   t  y   i  s   1 .   0

   /   1 .   2  m  m    T

   h   i  c   k  n  e  s  s

    M  e   d   i  u  m    D

  u   t  y   i  s   1 .   5  m  m    T

   h   i  c   k  n  e  s  s

    H  e  a  v  y   D  u   t  y   i  s   2 .   0

   /   2 .   5  m  m    T

   h   i  c   k  n  e  s  s

   W   I   D   T   H

WIDTH

THICKNESS

    L   i  g   h   t   D  u   t  y   i  s   1 .   0

   /   1 .   2  m  m    T

   h   i  c   k  n  e  s  s

    M  e

   d   i  u  m    D

  u   t  y   i  s   1 .   5  m  m    T

   h   i  c   k  n  e  s  s

    H  e  a

  v  y   D  u   t  y   i  s   2 .   0

   /   2 .   5  m  m    T

   h   i  c   k  n  e  s  s

Outside Flange (SO) Inside Flange (SI)Outside 900 (SN) Plain (SP)

1.0/1.2/1.5/2.0

1.0/1.2/1.5/2.0

1.0/1.2/1.5/2.0

1.0/1.2/1.5/2.0

1.0/1.2/1.5/2.0

1.2/1.5/2.0

1.2/1.5/2.0

1.2/1.5/2.0

1.5/2.0

1.5/2.0

1.5/2.0

1.5/2.0

2.00

2.00

2.00

2.00

2.00

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

Steel Type AccessoryTray Type Thickness mm PerformanceHeightmmWidth mm

50 / 25

75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

50

75

100

150

200

225

250

300

400

450

500

600

750

800

900

1050

1200

SI

SI

SI

SI

SI

SI

SI

SI

SI

SI

SI

SI

SI

SI

SI

SI

SI

TH

TH

TH

TH

TH

TH

TH

TH

TH

TH

TH

TH

TH

TH

TH

TH

TH

Remarks

* Thickness is minimum recommended as per TMI  manufacturing standard.

* Heights available are standard, other heights are available as special request.

* Standard Couplers size is 180mm x side height of Tray. ( Reference ________ page____ 

* Standard Hardware M6 Bolts for Cable Tray with M6 Nuts and Washer. Ref._____ 

* Model represents the inside ange type. Other anges available upon request as per below.

Tee Horizontal

* Unequal tee A,B,C will be as per specication.

* Equal tee A=B=C=Width.

C

B

ASLOT20x7

Page 11: Cable Management System

8/9/2019 Cable Management System

http://slidepdf.com/reader/full/cable-management-system 11/447 8

   S   L   O   T   2   0  x   7

1.0/1.2/1.5/2.0

1.0/1.2/1.5/2.0

1.0/1.2/1.5/2.0

1.0/1.2/1.5/2.0

1.0/1.2/1.5/2.0

1.2/1.5/2.0

1.2/1.5/2.0

1.2/1.5/2.0

1.5/2.0

1.5/2.0

1.5/2.0

1.5/2.0

2.00

2.00

2.00

2.00

2.00

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

Steel Type AccessoryTray Type Thickness mm PerformanceHeightmmWidth mm

50 / 25

75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

50

75

100

150

200

225

250

300

400

450

500

600

750

800

900

1050

1200

SI

SI

SI

SI

SI

SI

SI

SI

SI

SI

SI

SI

SI

SI

SI

SI

SI

B45

B45

B45

B45

B45

B45

B45

B45

B45

B45

B45

B45

B45

B45

B45

B45

B45

Bend 450

Remarks

* Thickness is minimum recommended as per TMI manufacturing standard.

* Heights available are standard, other heights are available as special request.

* Standard Couplers size is 180mm x side height of Tray.

* Standard Hardware M6 Bolts for Cable Tray with M6 Nuts and Washer.

* Model represents the inside ange type. Other anges available upon request as per below.

Outside Flange (SO) Inside Flange (SI)Outside 900 (SN) Plain (SP)WIDTH

THICKNESS

    L   i  g   h   t   D  u   t  y   i  s   1 .   0

   /   1 .   2  m  m    T

   h   i  c   k  n  e  s  s

    M  e   d   i  u  m    D

  u   t  y   i  s   1 .   5

  m  m    T

   h   i  c   k  n  e  s  s

    H  e  a  v  y   D  u   t  y   i  s   2 .   0

   /   2 .

   5  m  m    T

   h   i  c   k  n  e  s  s

1.0/1.2/1.5/2.0

1.0/1.2/1.5/2.0

1.0/1.2/1.5/2.0

1.0/1.2/1.5/2.0

1.0/1.2/1.5/2.0

1.2/1.5/2.0

1.2/1.5/2.0

1.2/1.5/2.0

1.5/2.0

1.5/2.0

1.5/2.0

1.5/2.0

2.00

2.00

2.00

2.00

2.00

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

Steel Type AccessoryTray Type Thickness mm PerformanceHeightmmWidth mm

50 / 25

75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

50

75

100

150

200

225

250

300

400

450

500

600

750

800

900

1050

1200

SI

SI

SI

SI

SI

SI

SI

SI

SI

SI

SI

SI

SI

SI

SI

SI

SI

B90

B90

B90

B90

B90

B90

B90

B90

B90

B90

B90

B90

B90

B90

B90

B90

B90

Bend 900

Remarks

* Thickness is minimum recommended as per TMI manufacturing standard.

* Heights available are standard, other heights are available as special request.

* Standard Couplers size is 180mm x side height of Tray.

* Standard Hardware M6 Bolts for Cable Tray with M6 Nuts and Washer.

* Model represents the inside ange type. Other anges available upon request as per below.

Outside Flange (SO) Inside Flange (SI)Outside 900 (SN) Plain (SP)

THICKNESS

   S   L   O   T   2   0  x   7

WIDTH

    L   i  g   h   t   D  u   t  y   i  s   1 .   0

   /   1 .   2  m  m    T

   h   i  c   k  n  e  s  s

    M  e   d   i  u  m    D

  u   t  y   i  s   1 .   5  m  m    T

   h   i  c   k  n  e  s  s

    H  e  a  v  y   D  u   t  y   i  s   2 .   0

   /   2 .   5  m  m    T

   h   i  c   k  n  e  s  s

1.0/1.2/1.5/2.0

1.0/1.2/1.5/2.0

1.0/1.2/1.5/2.0

1.0/1.2/1.5/2.0

1.0/1.2/1.5/2.0

1.2/1.5/2.0

1.2/1.5/2.0

1.2/1.5/2.0

1.5/2.0

1.5/2.0

1.5/2.0

1.5/2.0

2.00

2.00

2.00

2.00

2.00

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

Steel Type AccessoryTray Type Thickness mm PerformanceHeightmmWidth mm

50 / 25

75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

SI

SI

SI

SI

SI

SI

SI

SI

SI

SI

SI

SI

SI

SI

SI

SI

SI

RS

RS

RS

RS

RS

RS

RS

RS

RS

RS

RS

RS

RS

RS

RS

RS

RS

50

75

100

150

200

225

250

300

400

450

500

600

750

800

900

1050

1200

Reducer Straight

Remarks

* Thickness is minimum recommended as per TMI manufacturing standard.

* Heights available are standard, other heights are available as special request.

* Standard Couplers size is 180mm x side height of Tray.

* Standard Hardware M6 Bolts for Cable Tray with M6 Nuts and Washer.

* Model represents the inside ange type. Other anges available upon request as per below.

Outside Flange (SO) Inside Flange (SI)Outside 900 (SN) Plain (SN)

SLOT 20x7

WIDTH

WIDTH

THICKNESS

HEIGHT

    L   i  g   h   t   D  u   t  y   i  s   1 .   0

   /   1 .   2  m  m    T

   h   i  c   k  n  e  s  s

    M  e   d   i  u  m    D

  u   t  y   i  s   1 .   5  m  m    T

   h   i  c   k  n  e  s  s

    H  e  a  v  y   D  u   t  y   i  s   2 .   0

   /   2 .   5  m  m

    T   h   i  c   k  n  e  s  s

A

B

* A= 50 mm to 1000 mm and B= 75 mm to 1200 mm, B will remain always greater than A.

1.0/1.2/1.5/2.0

1.0/1.2/1.5/2.0

1.0/1.2/1.5/2.0

1.0/1.2/1.5/2.0

1.0/1.2/1.5/2.0

1.2/1.5/2.0

1.2/1.5/2.0

1.2/1.5/2.0

1.5/2.0

1.5/2.0

1.5/2.0

1.5/2.0

2.00

2.00

2.00

2.00

2.00

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

Steel Type AccessoryTray Type Thickness mm PerformanceHeightmmWidth mm

50 / 25

75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

SI

SI

SI

SI

SI

SI

SI

SI

SI

SI

SI

SI

SI

SI

SI

SI

SI

RL

RL

RL

RL

RL

RL

RL

RL

RL

RL

RL

RL

RL

RL

RL

RLRL

50

75

100

150

200

225

250

300

400

450

500

600

750

800

900

1050

1200

Reducer Left

Remarks

* Thickness is minimum recommended as per TMI manufacturing standard.

* Heights available are standard, other heights are available as special request.

* Standard Couplers size is 180mm x side height of Tray.

* Standard Hardware M6 Bolts for Cable Tray with M6 Nuts and Washer.

* Model represents the inside ange type. Other anges available upon request as per below.

Outside Flange (SO) Inside Flange (SI)Outside 900 (SO) Plain (SN)

   S   L   O   T   2   0  x   7

WIDTH

WIDTH

THICKNESS

HEIGHT

    L   i  g   h   t   D  u   t  y   i  s   1 .   0

   /   1 .   2  m  m    T

   h   i  c   k  n  e  s  s

    M  e   d   i  u  m    D

  u   t  y   i  s   1 .   5  m  m    T

   h   i  c   k  n  e  s  s

    H  e  a  v  y   D  u   t  y   i  s   2 .   0

   /   2 .   5  m  m    T

   h   i  c   k  n  e  s  s

A

B

* A= 50 mm to 1000 mm and B= 75 mm to 1200 mm, B will remain always greater than A.

Page 12: Cable Management System

8/9/2019 Cable Management System

http://slidepdf.com/reader/full/cable-management-system 12/449 10

1.0/1.2/1.5/2.0

1.0/1.2/1.5/2.0

1.0/1.2/1.5/2.0

1.0/1.2/1.5/2.0

1.0/1.2/1.5/2.0

1.2/1.5/2.0

1.2/1.5/2.0

1.2/1.5/2.0

1.5/2.0

1.5/2.0

1.5/2.0

1.5/2.0

2.00

2.00

2.00

2.00

2.00

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

Steel Type AccessoryTray Type Thickness mm PerformanceHeightmmWidth mm

50 / 25

75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

50

75

100

150

200

225

250

300

400

450

500

600

750

800

900

1050

1200

SI

SI

SI

SI

SI

SI

SI

SI

SI

SI

SI

SI

SI

SI

SI

SI

SI

ER

ER

ER

ER

ER

ER

ER

ER

ER

ER

ER

ER

ER

ER

ER

ER

ER

Remarks

* Thickness is minimum recommended as per TMI  manufacturing standard.

* Heights available are standard, other heights are available as special request.

* Standard Couplers size is 180mm x side height of Tray.

* Standard Hardware M6 Bolts for Cable Tray with M6 Nuts and Washer.

* Model represents the inside fange type. Other fanges available upon request as per below.

External Riser

Outside Flange (SO) Inside Flange (SI)Outside 900 (SN) Plain (SP)

   S   L   O   T   2   0  x   7

WIDTHTHICKNESS

HEIGHT

    L   i  g   h   t   D  u   t  y   i  s   1 .   0

   /   1 .   2  m  m    T

   h   i  c   k  n  e  s  s

    M  e   d   i  u  m    D

  u   t  y   i  s   1 .   5  m  m    T

   h   i  c   k  n  e  s  s

    H  e  a  v  y   D  u   t  y   i  s   2 .   0

   /   2 .   5  m  m    T

   h   i  c   k  n  e  s  s

Outside Flange (SO) Inside Flange (SI)Outside 900 (SN) Plain (SP)

1.0/1.2/1.5/2.0

1.0/1.2/1.5/2.0

1.0/1.2/1.5/2.0

1.0/1.2/1.5/2.0

1.0/1.2/1.5/2.0

1.2/1.5/2.0

1.2/1.5/2.0

1.2/1.5/2.0

1.5/2.0

1.5/2.0

1.5/2.0

1.5/2.0

2.00

2.00

2.00

2.00

2.00

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

Steel Type AccessoryTray Type Thickness mm PerformanceHeightmmWidth mm

50 / 25

75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

50

75

100

150

200

225

250

300

400

450

500

600

750

800

900

1050

1200

SI

SI

SI

SI

SI

SI

SI

SI

SI

SI

SI

SI

SI

SI

SI

SI

SI

IR

IR

IR

IR

IR

IR

IR

IR

IR

IR

IR

IR

IR

IR

IR

IR

IR

Internal Riser

Remarks

* Thickness is minimum recommended as per TMI manufacturing standard.

* Heights available are standard, other heights are available as special request.

* Standard Couplers size is 180mm x side height of Tray

* Standard Hardware M6 Bolts for Cable Tray with M6 Nuts and Washer

* Model represents the inside ange type. Other anges available upon request as per below.

   S   L   O   T   2   0  x

   7

WIDTH

   H   E   I   G   H

   T

    L   i  g   h   t   D  u   t  y   i  s   1 .   0

   /   1 .   2  m  m    T   h   i  c   k  n  e  s  s

    M  e   d   i  u  m    D

  u   t  y   i  s   1 .   5  m  m    T

   h   i  c   k  n  e  s  s

    H  e  a  v  y   D  u   t  y   i  s   2 .   0

   /   2 .   5  m  m    T

   h   i  c   k  n  e  s  s

1.0/1.2/1.5/2.0

1.0/1.2/1.5/2.0

1.0/1.2/1.5/2.0

1.0/1.2/1.5/2.0

1.0/1.2/1.5/2.0

1.2/1.5/2.0

1.2/1.5/2.0

1.2/1.5/2.0

1.5/2.0

1.5/2.0

1.5/2.0

1.5/2.0

2.00

2.00

2.00

2.00

2.00

50

75

100

150

200

225

250

300

400

450

500

600

750

800

900

1050

1200

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

Steel Type AccessoryTray Type Thickness mm PerformanceHeightmmWidth mm

50 / 25

75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

SI

SI

SI

SI

SI

SI

SI

SI

SI

SI

SI

SI

SI

SI

SI

SI

SI

RR

RR

RR

RR

RR

RR

RR

RR

RR

RR

RR

RR

RR

RR

RR

RR

RR

50

75

100

150

200

225

250

300

400

450

500

600

750

800

900

1050

1200

X y

Reducer Right

Remarks

* Thickness is minimum recommended as per TMI manufacturing standard.

* Heights available are standard, other heights are available as special request.

* Standard Couplers size is 180mm x side height of Tray.

* Standard Hardware M6 Bolts for Cable Tray with M6 Nuts and Washer.

* Model represents the inside ange type. Other anges available upon request as per below.

Outside Flange (SO) Inside Flange (SI)Outside 900 (SO) Plain (SN)

   S   L   O   T   2   0  x   7

WIDTH

WIDTHTHICKNESS

HEIGHT

    L   i  g   h   t   D  u   t  y   i  s   1 .   0

   /   1 .   2  m  m 

   T   h   i  c   k  n  e  s  s

    M  e   d   i  u  m    D

  u   t  y   i  s   1 .   5  m  m    T

   h   i  c   k  n  e  s  s

    H  e  a  v  y   D  u   t  y   i  s   2 .   0

   /   2 .   5  m  m    T

   h   i  c   k  n  e  s  s

A

B

* A= 50 mm to 1000 mm and B= 75 mm to 1200 mm, B will remain always greater than A.

Page 13: Cable Management System

8/9/2019 Cable Management System

http://slidepdf.com/reader/full/cable-management-system 13/44

Cable Ladder System Overview

11 12

Bend 450

Tee Horizontal

Tee Horizontal

Sub Divider

Straight Reducer

Cross Horizontal

Internal Riser

Straight Ladder

Straight Ladder

Bend 90°

Page 14: Cable Management System

8/9/2019 Cable Management System

http://slidepdf.com/reader/full/cable-management-system 14/4413

CL-HD-I-300-50-2-3000

C.L Type

• NC Type(NC)

• OC Type(OC)

• OG Type (OG)

• Z Type (Z)

Length ofLadder

Steel Thickness

Side Height

Width

Cable Ladder Straight - Ordering Guide (CL)

Cable Ladder Fittings - Ordering Guide (CL)

Finishing • HDG• GI• AL• SS4• SS6• SS6L

Material Type •Cable Ladder

CL-HD-IR-300-50-2-RS

Fittings • Internal Riser (IR)• Cross Horizontal (CH)• Tee Horizontal (TH)• Bend 900 (B90)• Bend 450 (B45)• Reducer Straight (RS)• Reducer left (RL)• Reducer Right (RR)• Internal Riser (IR)• External Riser (ER)• Unequal Tee (UT)

Radius/Standard...etc

Side Height

Width

Steel Thickness

1.0

1.2

1.2

1.2

1.5

1.5

1.5

1.5

2.0

2.0

2.0

2.0

2.5

2.5

2.5

2.5

2.5

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

Steel Type Tray Type Height mm Thickness mm Length mmWidth mm

50

50/75

50/75/100

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000

2440/3000

50

75

100

150

200

225

250

300

400

450

500

600

750

800

900

1050

1200

NC

NC

NC

NC

NC

NC

NCNC

NC

NC

NC

NC

NC

NC

NC

NC

NC

Performance

NC Type

Remarks

* Thickness is minimum recommended as per TMI manufacturing standard.

* Heights available are standard, other heights are available as special request.

* Useful depth is 25mm less than height in the schedule above.

* Standard Couplers size is 100 mm x side height of Ladder.

* Standard Hardware M8 Bolts for Cable Tray with M8 Nuts and Washer.

   S   L   O   T   2   0  x   7

   H   E   I   G   H   T

WIDTH LENGTH

THICKNESSOC Type

Remarks

* Thickness is minimum recommended as per TMI manufacturing standard.

* Heights available are standard, other heights are available as special request.

* Useful depth is 25mm less than height in the schedule above.

* Standard Couplers size is 100 mm x side height of Ladder.

* Standard Hardware M8 Bolts for Cable Tray with M8 Nuts and Washer.

   H   E   I   G   H   T

   S   L   O   T   2   0  x   7

WIDTH LENGTH

THICKNESS

1.0

1.2

1.2

1.2

1.5

1.5

1.5

1.5

2.0

2.0

2.0

2.0

2.5

2.5

2.5

2.5

2.5

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

Steel Type Tray Type Height mm Thickness mm Length mmWidth mm

50

50/75

50/75/100

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000

2440/3000

50

75

100

150

200

225

250

300

400

450

500

600

750

800

900

1050

1200

OC

OC

OC

OC

OC

OC

OC

OC

OC

OC

OC

OC

OC

OC

OCOC

OC

Performance

Cable Ladder Straight

    L   i  g   h   t   D  u   t  y   i  s   1 .   0

   /   1 .   2  m  m

    T   h   i  c   k  n  e  s  s

    M  e   d   i  u  m    D

  u   t  y   i  s   1 .   5  m  m    T

   h   i  c   k  n  e  s  s

    H  e  a  v  y   D  u   t  y   i  s   2 .   0

   /   2 .   5  m  m

    T   h   i  c   k  n  e  s  s

    L   i  g   h   t   D  u   t  y   i  s   1 .   0

   /   1 .   2  m  m    T

   h   i  c   k  n  e  s  s

    M  e   d   i  u  m    D

  u   t  y   i  s   1 .   5  m  m    T

   h   i  c   k  n  e  s  s

    H  e  a  v  y   D  u   t  y   i  s   2 .   0

   /   2 .   5  m  m    T

   h   i  c   k  n  e  s  s

   3   0   0

   3   4   1

   3   0   0

   3   4   1

Material Type

•Cable Ladder

Finishing

• HDG

• GI

• AL

• SS4

• SS6

• SS6L

14

Page 15: Cable Management System

8/9/2019 Cable Management System

http://slidepdf.com/reader/full/cable-management-system 15/44

1.0

1.2

1.2

1.2

1.5

1.5

1.5

1.5

2.0

2.0

2.0

2.0

2.5

2.5

2.5

2.5

2.5

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

Steel Type Tray Type Height mm Thickness mm Length mmWidth mm

50

50/75

50/75/100

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/15050/75/100/125/150

50/75/100/125/150

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000

2440/3000

50

75

100

150

200

225

250

300

400

450

500

600

750

800

900

1050

1200

Z

Z

Z

Z

Z

Z

Z

Z

Z

Z

Z

Z

Z

Z

Z

Z

Z

Performance

Z Type

Remarks

* Thickness is minimum recommended as per TMI  manufacturing standard.

* Heights available are standard, other heights are available as special request.

* Useful depth is 25mm less than height in the schedule above.

* Standard Couplers size is 100 mm x side height of Ladder.

* Standard Hardware M8 Bolts for Cable Tray with M8 Nuts and Washer.

1.0

1.2

1.2

1.2

1.5

1.5

1.5

1.5

2.0

2.0

2.0

2.0

2.5

2.5

2.5

2.5

2.5

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6LHD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

Steel Type Tray Type Height mm Thickness mm Length mmWidth mm

50

50/75

50/75/100

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/60002440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000

2440/3000

50

75

100

150

200

225

250300

400

450

500

600

750

800

900

1050

1200

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

Performance

OG Type

Remarks

* Thickness is minimum recommended as per TMI  manufacturing standard.

* Heights available are standard, other heights are available as special request.

* Useful depth is 25mm less than height in the schedule above.

* Standard Couplers size is 100 mm x side height of Ladder.

* Standard Hardware M8 Bolts for Cable Tray with M8 Nuts and Washer.

   H   E   I   G   H   T

   S   L   O   T   2   0  x   7

WIDTH LENGTH

THICKNESS

   H   E   I   G   H   T

   S   L   O   T   2   0  x   7

WIDTH LENGTH

THICKNESS

    L   i  g   h   t   D  u   t  y   i  s   1 .   0

   /   1 .   2  m  m

    T   h   i  c   k  n  e  s  s

    M  e   d   i  u  m    D

  u   t  y   i  s   1 .   5  m  m    T

   h   i  c   k  n  e  s  s

    H  e  a  v  y   D  u   t  y   i  s   2 .   0

   /   2 .   5  m  m

    T   h   i  c   k  n  e  s  s

    L   i  g   h   t   D  u   t  y   i  s   1 .   0

   /   1 .   2  m  m    T

   h   i  c   k  n  e  s  s

    M  e   d   i  u  m    D

  u   t  y   i  s   1 .   5  m  m    T

   h   i  c   k  n  e  s  s

    H  e  a  v  y   D  u   t  y   i  s   2 .   0

   /   2 .   5  m  m    T

   h   i  c   k  n  e  s  s

   3   0   0

   3   4   1

   3   0   0

   3   4   1

Cable Ladder-Fittings

WIDTH

HEIGHT

16

1.0

1.2

1.2

1.2

1.5

1.5

1.5

1.5

2.0

2.0

2.0

2.0

2.5

2.5

2.5

2.5

2.5

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

Steel Type AccessoryTray Type

50

75

100

150

200

225

250

300

400

450

500

600

750

800

900

1050

1200

Thickness mmHeightmmWidth mm

50

50/75

50/75/100

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

CH

CH

CH

CH

CH

CH

CH

CH

CH

CH

CH

CH

CH

CH

CH

CH

CH

Performance

Cross Horizontal

NC Type (NC) Z Type (Z)O C T yp e ( OC ) O G T yp e ( OG ) SLOT 20x7

    L   i  g   h   t   D  u   t  y   i  s   1 .   0

   /   1 .   2  m

  m    T

   h   i  c   k  n  e  s  s

    M  e   d   i  u  m    D

  u   t  y   i  s   1 .   5  m  m    T

   h   i  c   k  n  e  s  s

    H  e  a  v  y   D  u   t  y   i  s   2 .   0

   /   2 .   5  m

  m    T

   h   i  c   k  n  e  s  s

Remarks

* Thickness is minimum recommended as per TMI  manufacturing standard.

* Heights available are standard, other heights are available as special request.

* Useful depth is 25mm less than height in the schedule above.

* Standard Couplers size is 100 mm x side height of Ladder.

* Standard Hardware M8 Bolts for Cable Tray with M8 Nuts and Washer.

* Model represents the OG type. Other anges available upon request as per below.

* Unequal cross A,B,C,D will be as per specication.

* Equal cross A=B=C=D=Width.

1.0

1.2

1.2

1.2

1.5

1.5

1.5

1.5

2.0

2.0

2.0

2.0

2.5

2.5

2.5

2.5

2.5

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

Steel Type AccessoryTray Type

50

75

100

150

200

225

250

300

400

450

500

600

750

800

900

1050

1200

Thickness mmHeightmmWidth mm

50

50/75

50/75/100

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

TH

TH

TH

TH

TH

TH

TH

TH

TH

TH

TH

TH

TH

TH

TH

TH

TH

Performance

Tee Horizontal

NC Type (NC) Z Type (Z)O C T yp e ( OC ) O G T yp e ( OG )

WIDTH   L   i  g   h   t   D  u   t  y   i  s   1 .   0

   /   1 .   2  m  m    T

   h   i  c   k  n  e  s  s

    M  e   d   i  u  m    D

  u   t  y   i  s   1 .   5  m  m    T

   h   i  c   k  n  e  s  s

    H  e  a  v  y   D  u   t  y   i  s   2 .   0

   /   2 .   5  m  m    T

   h   i  c   k  n  e  s  s

Remarks

* Thickness is minimum recommended as per TMI  manufacturing standard.

* Heights available are standard, other heights are available as special request.

* Useful depth is 25mm less than height in the schedule above.

* Standard Couplers size is 100 mm x side height of Ladder.

* Standard Hardware M8 Bolts for Cable Tray with M8 Nuts and Washer.

* Model represents the OG type. Other anges available upon request as per below.

* Unequal cross A,B,C,D will be as per specication.

* Equal cross A=B=C=D=Width.

A

D

C

B

 T   H I     C  K  N E   S   S  

HEIGHT

   S   L   O   T   2   0  x   7

C

B

A

   T   H   I   C   K   N   E   S   S

15

Page 16: Cable Management System

8/9/2019 Cable Management System

http://slidepdf.com/reader/full/cable-management-system 16/44

1.0

1.2

1.2

1.2

1.5

1.5

1.5

1.5

2.0

2.0

2.0

2.0

2.5

2.5

2.5

2.5

2.5

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

Steel Type AccessoryTray Type

50

75

100

150

200

225

250

300

400

450

500

600

750

800

900

1050

1200

Thickness mmHeightmmWidth mm

50

50/75

50/75/100

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

B45

B45

B45

B45

B45

B45

B45

B45

B45

B45

B45

B45

B45

B45

B45

B45

B45

Performance

1.0

1.2

1.2

1.2

1.5

1.5

1.5

1.5

2.0

2.0

2.0

2.0

2.5

2.5

2.5

2.5

2.5

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

Steel Type AccessoryTray Type

50

75

100

150

200

225

250

300

400

450

500

600

750

800

900

1050

1200

Thickness mmHeightmmWidth mm

50

50/75

50/75/100

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

B90

B90

B90

B90

B90

B90

B90

B90

B90

B90

B90

B90

B90

B90

B90

B90

B90

Performance

Bend 450

Remarks

* Thickness is minimum recommended as per TMI manufacturing standard.

* Heights available are standard, other heights are available as special request.

* Useful depth is 25mm less than height in the schedule above.

* Standard Couplers size is 100 mm x side height of Ladder.

* Standard Hardware M8 Bolts for Cable Tray with M8 Nuts and Washer.

* Model represents the OG type. Other anges available upon request as per below.

Remarks

* Thickness is minimum recommended as per TMI manufacturing standard.

* Heights available are standard, other heights are available as special request.

* Useful depth is 25mm less than height in the schedule above.

* Standard Couplers size is 100 mm x side height of Ladder.

* Standard Hardware M8 Bolts for Cable Tray with M8 Nuts and Washer.

* Model represents the OG type. Other anges available upon request as per below.

Bend 900

NC Type (NC) Z Type (Z)O C T yp e ( OC ) O G T yp e ( OG )

NC Type (NC) Z Type (Z)O C T yp e ( OC ) O G T yp e ( OG )

   T   H   I   C   K   N   E   S   S

   T   H   I   C   K   N   E   S   S

HEIGHT

SLOT 20x7

HEIGHT

   S   L   O   T   2   0  x   7   W

   I   D   T   H

   W   I   D   T   H

1.0

1.2

1.2

1.2

1.5

1.5

1.5

1.5

2.0

2.0

2.0

2.0

2.5

2.5

2.5

2.5

2.5

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

Steel Type AccessoryTray Type Thickness mmHeightmmWidth mm

50

50/75

50/75/100

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

RR

RR

RR

RR

RR

RR

RR

RR

RR

RR

RR

RR

RR

RR

RR

RRRR

50

75

100

150

200

225

250

300

400

450

500

600

750

800

900

1050

1200

Performance

1.0

1.2

1.2

1.2

1.5

1.5

1.5

1.5

2.0

2.0

2.0

2.0

2.5

2.5

2.5

2.5

2.5

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

Steel Type AccessoryTray Type Thickness mmHeightmmWidth mm

50

50/75

50/75/100

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

RS

RS

RS

RS

RS

RS

RS

RS

RSRS

RS

RS

RS

RS

RS

RS

RS

50

75

100

150

200

225

250

300

400

450

500

600

750

800

900

1050

1200

Performance

Reducer Straight

Remarks

* Thickness is minimum recommended as per TMI manufacturing standard.

* Heights available are standard, other heights are available as special request.

* Useful depth is 25mm less than height in the schedule above.

* Standard Couplers size is 100 mm x side height of Ladder.

* Standard Hardware M8 Bolts for Cable Tray with M8 Nuts and Washer.

* Model represents the OG type. Other anges available upon request as per below.

Remarks

* Thickness is minimum recommended as per TMI manufacturing standard.

* Heights available are standard, other heights are available as special request.

* Useful depth is 25mm less than height in the schedule above.

* Standard Couplers size is 100 mm x side height of Ladder.

* Standard Hardware M8 Bolts for Cable Tray with M8 Nuts and Washer.

* Model represents the OG type. Other anges available upon request as per below.

Reducer Right

NC Type (NC) Z Type (Z)O C T yp e ( OC ) O G T yp e ( OG )

NC Type (NC) Z Type (Z)O C T yp e ( OC ) O G T yp e ( OG )

   H   E   I   G   H   T

THICKNESS

   H   E   I   G   H   T

WIDTH

WIDTH

THICKNESS

SLOT 20x7

WIDTH

WIDTH

SLOT 20x7

17 18

    L   i  g   h   t   D  u   t  y   i  s   1 .   0   /

   1 .   2  m  m    T

   h   i  c   k  n  e  s  s

    M  e   d   i  u  m    D

  u   t  y   i  s   1

 .   5  m  m    T

   h   i  c   k  n  e  s  s

    H  e  a  v  y   D  u   t  y   i  s   2 .   0   /

   2 .   5  m  m    T

   h   i  c   k  n  e  s  s

    L   i  g   h   t   D  u   t  y   i  s   1 .   0

   /   1 .   2  m  m    T

   h   i  c   k  n  e  s  s

    M  e   d   i  u  m    D

  u   t  y   i  s   1 .   5  m  m    T

   h   i  c   k  n  e  s  s

    H  e  a  v  y   D  u   t  y   i  s   2 .   0

   /   2 .   5  m  m    T

   h   i  c   k  n  e  s  s

    L   i  g   h   t   D  u   t  y   i  s   1 .   0   /

   1 .   2  m  m    T

   h   i  c   k  n  e  s  s

    M  e   d   i  u  m    D

  u   t  y   i  s   1

 .   5  m  m    T

   h   i  c   k  n  e  s  s

    H  e  a  v  y   D  u   t  y   i  s   2 .   0   /

   2 .   5  m  m    T

   h   i  c   k  n  e  s  s

    L   i  g   h   t   D  u   t  y   i  s   1 .   0

   /   1 .   2  m  m    T

   h   i  c   k  n  e  s  s

    M  e   d   i  u  m    D

  u   t  y   i  s   1 .   5  m  m    T

   h   i  c   k  n  e  s  s

    H  e  a  v  y   D  u   t  y   i  s   2 .   0

   /   2 .   5  m  m    T

   h   i  c   k  n  e  s  s

A

B* A= 50 mm to 1000 mm and B= 75 mm to 1200 mm, B will remain always greater than A.

* A= 50 mm to 1000 mm and B= 75 mm to 1200 mm, B will remain always greater than A.

A

B

Page 17: Cable Management System

8/9/2019 Cable Management System

http://slidepdf.com/reader/full/cable-management-system 17/44

1.0

1.2

1.2

1.2

1.5

1.5

1.5

1.5

2.0

2.0

2.0

2.0

2.5

2.5

2.5

2.5

2.5

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

Steel Type AccessoryTray Type

50

75

100

150

200

225

250

300

400

450

500

600

750

800

900

1050

1200

Thickness mmHeightmmWidth mm

50

50/75

50/75/100

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

ER

ER

ER

ER

ER

ER

ER

ER

ER

ER

ER

ER

ER

ER

ER

ER

ER

Performance

Reducer Left

Remarks

* Thickness is minimum recommended as per TMI manufacturing standard.

* Heights available are standard, other heights are available as special request.

* Useful depth is 25mm less than height in the schedule above.

* Standard Couplers size is 100 mm x side height of Ladder.

* Standard Hardware M8 Bolts for Cable Tray with M8 Nuts and Washer.

* Model represents the OG type. Other anges available upon request as per below.

Remarks

* Thickness is minimum recommended as per TMI manufacturing standard.

* Heights available are standard, other heights are available as special request.

* Useful depth is 25mm less than height in the schedule above.

* Standard Couplers size is 100 mm x side height of Ladder.

* Standard Hardware M8 Bolts for Cable Tray with M8 Nuts and Washer.

* Model represents the OG type. Other anges available upon request as per below.

External Riser

NC Type (NC) Z Type (Z)O C T yp e ( OC ) O G T yp e ( OG )

NC Type (NC) Z Type (Z)O C T yp e ( OC ) O G T yp e ( OG )

WIDTH

WIDTH

SLOT 20x7

   H   E   I   G   H   T

THICKNESS

WIDTH

   S   L   O   T   2   0  x   7

HEIGHT

   T   H   I   C   K   N   E   S   S

1.0

1.2

1.2

1.2

1.5

1.5

1.5

1.5

2.0

2.0

2.0

2.0

2.5

2.5

2.5

2.5

2.5

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

Steel Type AccessoryTray Type Thickness mmHeightmmWidth mm

50

50/75

50/75/100

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

RS

RS

RS

RS

RS

RS

RS

RS

RSRS

RS

RS

RS

RS

RS

RS

RS

50

75

100

150

200

225

250

300

400

450

500

600

750

800

900

1050

1200

50

75

100

150

200

225

250

300

400

450

500

600

750

800

900

1050

1200

X yPerformance

50

75

100

150

200

225

250

300

400

450

500

600

750

800

900

1050

1200

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

Steel Type AccessoryTray Type Thickness mm PerformanceHeightmmWidth mm

50 / 25

75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

100/ 75 /50 / 25

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

UT

UT

UT

UT

UT

UT

UT

UT

UT

UT

UT

UT

UT

UT

UT

UT

UT

1.0

1.2

1.2

1.2

1.5

1.5

1.5

1.5

2.0

2.0

2.0

2.0

2.5

2.5

2.5

2.5

2.5

50

75

100

150

200

225

250

300

400

450

500

600

750

800

900

1050

1200

X y

Internal Riser

Remarks

* Thickness is minimum recommended as per TMI manufacturing standard.

* Heights available are standard, other heights are available as special request.

* Useful depth is 25mm less than height in the schedule above.

* Standard Couplers size is 100 mm x side height of Ladder.

* Standard Hardware M8 Bolts for Cable Tray with M8 Nuts and Washer.

* Model represents the OG type. Other anges available upon request as per below.

Remarks

* Thickness is minimum recommended as per TMI manufacturing standard.

* Heights available are standard, other heights are available as special request.

* Useful depth is 25mm less than height in the schedule above.

* Standard Couplers size is 100 mm x side height of Ladder.

* Standard Hardware M8 Bolts for Cable Tray with M8 Nuts and Washer.

* Model represents the OG type. Other anges available upon request as per below.

Sub Divider

NC Type (NC) Z Type (Z)O C T yp e ( OC ) O G T yp e ( OG )

NC Type (NC) Z Type (Z)O C T yp e ( OC ) O G T yp e ( OG )

HEIGHT

WIDTH

   T   H   I   C   K   N   E   S   S

   S   L   O   T   2   0  x   7

HEIGHT WIDTH

THICKNESS

   S   L   O   T   2   0  x   7

1.0

1.2

1.2

1.2

1.5

1.5

1.5

1.5

2.0

2.0

2.0

2.0

2.5

2.5

2.5

2.5

2.5

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

Steel Type AccessoryTray Type

50

75

100

150

200

225

250

300

400

450

500

600

750

800

900

1050

1200

Thickness mmHeightmmWidth mm

50

50/75

50/75/100

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

50/75/100/125/150

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

OG

IR

IR

IR

IR

IR

IR

IR

IR

IRIR

IR

IR

IR

IR

IR

IR

IR

Performance

19 20

    L   i  g   h   t   D  u   t  y   i  s   1 .   0

   /   1 .   2  m  m    T

   h   i  c   k  n  e  s  s

    M  e   d   i  u  m    D

  u   t  y   i  s   1 .   5  m  m    T

   h   i  c   k  n  e  s  s

    H  e  a  v  y   D  u   t  y   i  s   2 .   0

   /   2 .   5  m  m    T

   h   i  c   k  n  e  s  s

    L   i  g   h   t   D  u   t  y   i  s   1 .   0   /

   1 .   2  m  m    T

   h   i  c   k  n  e  s  s

    M  e   d   i  u  m    D

  u   t  y   i  s   1

 .   5  m  m    T

   h   i  c   k  n  e  s  s

    H  e  a  v  y   D  u   t  y   i  s   2 .   0   /

   2 .   5  m  m    T

   h   i  c   k  n  e  s  s

    L   i  g   h   t   D  u   t  y   i  s   1 .   0

   /   1 .   2  m  m    T

   h   i  c   k  n  e  s  s

    M  e   d   i  u  m    D

  u   t  y   i  s   1 .   5  m  m    T

   h   i  c   k  n  e  s  s

    H  e  a  v  y   D  u   t  y   i  s   2 .   0

   /   2 .   5  m  m    T

   h   i  c   k  n  e  s  s

    L   i  g   h   t   D  u   t  y   i  s   1 .   0   /

   1 .   2  m  m    T

   h   i  c   k  n  e  s  s

    M  e   d   i  u  m    D

  u   t  y   i  s   1

 .   5  m  m    T

   h   i  c   k  n  e  s  s

    H  e  a  v  y   D  u   t  y   i  s   2 .   0   /

   2 .   5  m  m    T

   h   i  c   k  n  e  s  s

* A= 50 mm to 1000 mm and B= 75 mm to 1200 mm, B will remain always greater than A.

A

B

Page 18: Cable Management System

8/9/2019 Cable Management System

http://slidepdf.com/reader/full/cable-management-system 18/44

Cable Trunking System Overview

Equal Tee

Elbow 900

Elbow 450

Elbow 450

Equal Cross

900 Bend Inside Cover

Straight Reducer

Elbow 900

Straight Reducer

900 Bend Inside Cover

Straight Trunking

21 22

Page 19: Cable Management System

8/9/2019 Cable Management System

http://slidepdf.com/reader/full/cable-management-system 19/44

STN Type

Remarks

* Thickness is minimum recommended as per TMI manufacturing standard.

* Heights available are standard, other heights are available as special request.

* Standard Couplers size is 100mm x side height of Trunking.

* Standard Hardware M6 Bolts for Cable Tray with M6 Nuts and Washer.

* Cable Trunking Length is TMI manufacturing standard, other Lengths can be provided upon request.

1.0

1.0

1.2

1.5

1.5

1.5

2.0

2.0

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

GI

GI

GI

GI

GI

GI

GI

GI

Steel Type Tray Type Thickness mm Length mmHeightmmWidth mm

75 / 50

75 /50 

50/100

50/100/150

50/100/150

50/100/150

50/100/150

50/100/150

50

75

100

150

200

225

250

300

STN

STN

STN

STN

STN

STN

STN

STN

Performance

SLOT 12x7

   H   E   I   G   H   T

WIDTH

   L   E   N   G   T   H

    L   i  g   h

   t   D  u   t  y   i  s   1 .   0

   /   1 .   2  m  m    T

   h   i  c   k  n  e  s  s

    M  e   d   i  u  m    D

  u   t  y   i  s   1 .   5  m  m    T

   h   i  c   k  n  e  s  s

    H  e  a  v

  y   D  u   t  y   i  s   2 .   0

   /   2 .   5  m  m    T

   h   i  c   k  n  e  s  s

Cable Trunking Straight

Cable Trunking Straight - Ordering Guide (CR)

CR-HD-I-300-50-2-3000

Material Type

•Cable Trunking

Finishing

• HDG

• GI

• SS4

• AL

C.R TYPE

• STN Type (STN)

• DTN Type (DTN)• MTN Type (MTN)

Length ofTrunking

Steel Thickness

Side Height

Width

Finishing 

• HDG• GI

• AL

• SS4

Material Type •Cable Trunking

CR-HD-IR-300-50-2

Fittings 

• Bend 900 (B90 + TC,IC, OC)

• Bend 450 (B45 + TC,IC, OC)

• Tee Horizontal (TH + TC,IC, OC)

• Cross Top Cover (CHTC)

• Reducer Straight (RS)

• Ply Mouth (CTIC)

Side Height

Width

Steel Thickness

Cable Trunkng Fittings - Ordering Guide (CR)

23 24

Page 20: Cable Management System

8/9/2019 Cable Management System

http://slidepdf.com/reader/full/cable-management-system 20/44

   L   E   N   G   T   H

DTN Type

* Thickness is minimum recommended as per TMI  manufacturing standard.

* Heights available are standard, other heights are available as special request.

* Standard Couplers size is 100 mm x side height of Trunking.

* Standard Hardware M6 Bolts for Cable Tray with M6 Nuts and Washer.

* Cable Trunking Length is TMI manufacturing standard, other Lengths can be provided upon request.

   H   E   I   G   H   T

WIDTH

LENGTHSLOT 12x7

1.2

1.5

1.5

2.0

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

GI

GI

GI

GI

Steel Type Tray Type Thickness mm Length mmHeightmmWidth mm

50/100

50/100/150

50/100/150

50/100/150

100

  150

200

300

DTN

DTN

DTN

DTN

Performance

    L   i  g   h

   t   D  u   t  y   i  s   1 .   0

   /   1 .   2  m  m    T

   h   i  c   k  n  e  s  s

    M  e

   d   i  u  m    D

  u   t  y   i  s   1 .   5  m  m    T

   h   i  c   k  n  e  s  s

    H  e  a  v  y   D  u   t  y   i  s   2 .   0

   /   2 .   5  m  m    T

   h   i  c   k  n  e  s  s

   L   E   N   G   T   H

MTN Type

* Thickness is minimum recommended as per TMI manufacturing standard.

* Heights available are standard, other heights are available as special request.

* Standard Couplers size is 100 mm x side height of Trunking.

* Standard Hardware M6 Bolts for Cable Tray with M6 Nuts and Washer.

* Cable Trunking Length is TMI manufacturing standard, other Lengths can be provided upon request.

   H   E   I   G   H   T

WIDTH SLOT 12x7

    L   i  g   h

   t   D  u   t  y   i  s   1 .   0

   /   1 .   2  m  m    T

   h   i  c   k  n  e  s  s

    M  e   d   i  u  m    D

  u   t  y   i  s   1 .   5  m  m    T

   h   i  c   k  n  e  s  s

    H  e  a  v  y   D  u   t  y   i  s   2 .   0

   /   2 .   5  m  m    T

   h   i  c   k  n  e  s  s

1.5

1.5

2.0

2.0

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

GI

GI

GI

GI

Steel Type Tray Type Thickness mm Length mmHeightmmWidth mm

50/100/150

50/100/150

 50/100/150

50/100/150

150

  225

300

450

MTN

MTN

MTN

MTN

Performance

25 26

Page 21: Cable Management System

8/9/2019 Cable Management System

http://slidepdf.com/reader/full/cable-management-system 21/44

Cable Trunking- Fittings

STN Type DTN Type MTN Type

GI

GI

GI

GI

GI

GI

GI

GI

S te el T y pe T ra y Ty pe A cc es so ry

1.0

1.0

1.2

1.5

1.5

1.5

2.0

2.0

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

Thickness mm Length mmHeightmmWidth mm

75

75 /50 

50/100

50/100/150

50/100/150

50/100/150

50/100/150

50/100/150

50

75

100

150

200

225

250

300

STN

STN

STN

STN

STN

STN

STNSTN

B90TC

B90TC

B90TC

B90TC

B90TC

B90TC

B90TCB90TC

Performance

Bend 900 Top Cover

Remarks

* Thickness is minimum recommended as per TMI manufacturing standard.

* Heights available are standard, other heights are available as special request.

* Standard Couplers size is 100 mm x side height of Trunking.

* Standard Hardware M8 Bolts for Cable Tray with M6 Nuts and Washer.

* Model represents the MTN type. Other anges available upon request as per below.

SLOT 12x7

HEIGHT   T   H   I   C   K   N   E   S   S

   W   I   D   T   H

    L   i  g   h   t   D  u   t  y   i  s   1 .   0

   /   1 .   2  m  m    T

   h   i  c   k  n  e  s  s

    M  e   d

   i  u  m    D

  u   t  y   i  s   1 .   5  m  m    T

   h   i  c   k  n  e  s  s

    H  e  a  v  y   D  u   t  y   i  s   2 .   0

   /   2 .   5  m  m    T

   h   i  c   k  n  e  s  s

STN Type DTN Type MTN Type

GI

GI

GI

GI

GI

GI

GI

GI

S tee lType Tray Type Accessory

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

1.0

1.0

1.2

1.5

1.5

1.5

2.0

2.0

Thickness mm Length mmHeightmmWidth mm

 50

75 /50 

50/100

50/100/150

50/100/150

50/100/150

50/100/150

50/100/150

50

75

100

150

200

225

250

300

STN

STN

STN

STN

STN

STN

STN

STN

B90IC

B90IC

B90IC

B90IC

B90IC

B90IC

B90IC

B90IC

Performance

Bend 900 Inside Cover

Remarks

* Thickness is minimum recommended as per TMI  manufacturing standard.

* Heights available are standard, other heights are available as special request.

* Standard Couplers size is 100 mm x side height of Trunking.

* Standard Hardware M8 Bolts for Cable Tray with M6 Nuts and Washer.

* Model represents the MTN type. Other anges available upon request as per below.

WIDTH

   S   L   O   T   1   2  x   7

   H   E   I   G   H   T

    L   i  g   h   t   D  u   t  y   i  s   1 .   0

   /   1 .   2  m  m    T

   h   i  c   k  n  e  s  s

    M  e   d   i  u  m    D

  u   t  y   i  s   1 .   5  m  m    T

   h   i  c   k  n  e  s  s

    H  e  a  v  y   D  u   t  y   i  s   2 .   0

   /   2 .   5  m  m    T

   h   i  c   k  n  e  s  s

STN Type DTN Type MTN Type

GI

GI

GI

GI

GI

GI

GI

GI

S te el T y pe T ra y Ty pe A cc es so ry

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

1.0

1.0

1.2

1.5

1.5

1.5

2.0

2.0

Thickness mm Length mmHeightmmWidth mm

  50

75 /50 

50/100

50/100/150

50/100/150

50/100/150

50/100/150

50/100/150

50

75

100

150

200

225

250

300

STN

STN

STN

STN

STN

STN

STN

STN

B90OC

B90OC

B90OC

B90OC

B90OC

B90OC

B90OC

B90OC

Performance

Bend 900 Outside Cover

Remarks

* Thickness is minimum recommended as per TMI  manufacturing standard.

* Heights available are standard, other heights are available as special request.

* Standard Couplers size is 100 mm x side height of Trunking.

* Standard Hardware M8 Bolts for Cable Tray with M6 Nuts and Washer.

* Model represents the MTN type. Other anges available upon request as per below.

   H   E   I   G   H   T

   S   L   O   T   1   2  x   7

   T   H   I   C   K   N   E   S   S

WIDTH

    L   i  g   h

   t   D  u   t  y   i  s   1 .   0

   /   1 .   2  m  m    T

   h   i  c   k  n  e  s  s

    M  e   d   i  u  m    D

  u   t  y   i  s   1 .   5  m  m    T

   h   i  c   k  n  e  s  s

    H  e  a  v  y   D  u   t  y   i  s   2 .   0

   /   2 .   5  m  m    T

   h   i  c   k  n  e  s  s

STN Type DTN Type MTN Type

GI

GI

GI

GI

GI

GI

GI

GI

S te el T yp e T ra y Ty pe A cc es s or y

1.0

1.0

1.2

1.5

1.5

1.5

2.0

2.0

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

Thickness mm Length mmHeightmmWidth mm

50

75 /50 

50/100

50/100/150

50/100/150

50/100/150

50/100/150

50/100/150

50

75

100

150

200

225

250

300

STN

STN

STN

STN

STN

STN

STN

STN

B45TC

B45TC

B45TC

B45TC

B45TC

B45TC

B45TC

B45TC

Performance

Bend 450 Top Cover

Remarks

* Thickness is minimum recommended as per TMI  manufacturing standard.

* Heights available are standard, other heights are available as special request.

* Standard Couplers size is 100 mm x side height of Trunking.

* Standard Hardware M8 Bolts for Cable Tray with M6 Nuts and Washer.* Model represents the MTN type. Other anges available upon request as per below.

HEIGHT

SLOT 12x7

   W   I   D   T   H

   T   H   I   C   K   N   E   S   S

    L   i  g   h   t   D  u   t  y   i  s   1 .   0

   /   1 .   2  m  m    T

   h   i  c   k  n  e  s  s

    M  e   d   i  u  m    D

  u   t  y   i  s   1 .   5  m  m    T

   h   i  c   k  n  e  s  s

    H  e  a  v  y   D  u   t  y   i  s   2 .   0

   /   2 .   5  m  m    T

   h   i  c   k  n  e  s  s

27 28

Page 22: Cable Management System

8/9/2019 Cable Management System

http://slidepdf.com/reader/full/cable-management-system 22/44

STN Type DTN Type MTN Type

GI

GI

GI

GI

GI

GI

GI

GI

S te el T y pe T ra y Ty pe A cc es so ry

1.0

1.0

1.2

1.5

1.5

1.5

2.0

2.0

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

Thickness mm Length mmHeightmmWidth mm

  50

75 /50 

50/100

50/100/150

50/100/150

50/100/150

50/100/150

50/100/150

50

75

100

150

200

225

250

300

STN

STN

STN

STN

STN

STN

STN

STN

B45OC

B45OC

B45OC

B45OC

B45OC

B45OC

B45OC

B45OC

Performance

Bend 450 Outside Cover

Remarks

* Thickness is minimum recommended as per TMI manufacturing standard.

* Heights available are standard, other heights are available as special request.

* Standard Couplers size is 100 mm x side height of Trunking.

* Standard Hardware M6 Bolts for Cable Tray with M8 Nuts and Washer.

* Model represents the MTN type. Other anges available upon request as per below.

WIDTH

S   L  O  T    1  2  x  7   

   T   H   I  C   K   N

   E   S   S

   H   E   I   G   H   T

    L   i  g   h   t   D  u   t  y   i  s   1 .   0

   /   1 .   2  m  m    T

   h   i  c   k  n  e  s  s

    M  e   d   i  u  m    D

  u   t  y   i  s   1 .   5  m  m    T

   h   i  c   k  n  e  s  s

    H  e  a  v  y   D  u   t  y   i  s   2 .   0

   /   2 .   5  m  m    T

   h   i  c   k  n  e  s  s

STN Type DTN Type MTN Type

GI

GI

GI

GI

GI

GI

GI

GI

S te el T yp e T ra y Ty pe A cc es so ry

1.0

1.0

1.2

1.5

1.5

1.5

2.0

2.0

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

Thickness mm Length mmHeightmmWidth mm

  50

75 /50 

50/100

50/100/150

50/100/150

50/100/150

50/100/150

50/100/150

50

75

100

150

200

225

250

300

STN

STN

STN

STN

STN

STN

STN

STN

CTTC

CTTC

CTTC

CTTC

CTTC

CTTC

CTTC

CTTC

Performance

Tee Top Cover

Remarks

* Thickness is minimum recommended as per TMI manufacturing standard.

* Heights available are standard, other heights are available as special request.

* Standard Couplers size is 100 mm x side height of Trunking.

* Standard Hardware M6 Bolts for Cable Tray with M8 Nuts and Washer.

* Model represents the MTN type. Other anges available upon request as per below.

WIDTH

   W   I   D   T   H

   S   L   O   T   1   2  x   7

HEIGHT

    L   i  g   h   t   D  u   t  y   i  s   1 .   0

   /   1 .   2  m  m    T

   h   i  c   k  n  e  s  s

    M  e

   d   i  u  m    D

  u   t  y   i  s   1 .   5  m  m    T

   h   i  c   k  n  e  s  s

    H  e  a  v  y   D  u   t  y   i  s   2 .   0

   /   2 .   5  m  m    T

   h   i  c   k  n  e  s  s

STN Type DTN Type MTN Type

GI

GI

GI

GI

GI

GI

GI

GI

S te el T yp e T ra y Ty pe A cc es s or y

1.0

1.0

1.2

1.5

1.5

1.5

2.0

2.0

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

Thickness mm Length mmHeightmmWidth mm

 50

75 /50 

50/100

50/100/150

50/100/150

50/100/150

50/100/150

50/100/150

50

75

100

150

200

225

250

300

STN

STN

STN

STN

STN

STN

STN

STN

CTIC

CTIC

CTIC

CTIC

CTIC

CTIC

CTIC

CTIC

Performance

Tee Inside Cover

Remarks

* Thickness is minimum recommended as per TMI manufacturing standard.

* Heights available are standard, other heights are available as special request.

* Standard Couplers size is 100 mm x side height of Trunking.* Standard Hardware M6 Bolts for Cable Tray with M8 Nuts and Washer.

* Model represents the MTN type. Other anges available upon request as per below.

HEIGHT

SLOT 12x7

   T   H   I   C   K   N   E   S   S

   W   I   D   T   H

    L   i  g   h   t   D  u   t  y   i  s   1 .   0

   /   1 .   2  m  m    T

   h   i  c   k  n  e  s  s

    M  e   d   i  u  m    D

  u   t  y   i  s   1 .   5  m  m    T

   h   i  c   k  n  e  s  s

    H  e  a  v  y   D  u   t  y   i  s   2 .   0

   /   2 .   5  m  m    T

   h   i  c   k  n  e  s  s

STN Type DTN Type MTN Type

GI

GI

GI

GI

GI

GI

GI

GI

S te el T y pe T ra y Ty pe A cc es so ry

1.0

1.0

1.2

1.5

1.5

1.5

2.0

2.0

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

Thickness mm Length mmHeightmmWidth mm

 50

75 /50 

50/100

50/100/150

50/100/150

50/100/150

50/100/150

50/100/150

50

75

100

150

200

225

250

300

STN

STN

STN

STN

STN

STN

STN

STN

B45IC

B45IC

B45IC

B45IC

B45IC

B45IC

B45IC

B45IC

Performance

Bend 450 Inside Cover

Remarks

* Thickness is minimum recommended as per TMI  manufacturing standard.

* Heights available are standard, other heights are available as special request. *

Standard Couplers size is 100 mm x side height of Trunking.

* Standard Hardware M6 Bolts for Cable Tray with M8 Nuts and Washer.

* Model represents the MTN type. Other anges available upon request as per below.

WIDTH

S   L  O  T    1  2  x  7   

   T   H   I  C   K   N

   E   S   S

   H   E   I   G   H   T

    L   i  g   h

   t   D  u   t  y   i  s   1 .   0

   /   1 .   2  m  m    T

   h   i  c   k  n  e  s  s

    M  e   d   i  u  m    D

  u   t  y   i  s   1 .   5  m  m    T

   h   i  c   k  n  e  s  s

    H  e  a  v  y   D  u   t  y   i  s   2 .   0

   /   2 .   5  m  m    T

   h   i  c   k  n  e  s  s

29 30

Page 23: Cable Management System

8/9/2019 Cable Management System

http://slidepdf.com/reader/full/cable-management-system 23/44

STN Type DTN Type MTN Type

GI

GI

GI

GI

GI

GI

GI

GI

S te el T yp e T ra y Ty pe A cc es so ry

1.0

1.0

1.2

1.5

1.5

1.5

2.0

2.0

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

Thickness mm Length mmHeightmmWidth mm

  50

75 /50 

50/100

50/100/150

50/100/150

50/100/150

50/100/150

50/100/150

50

75

100

150

200

225

250

300

STN

STN

STN

STN

STN

STN

STN

STN

CHTC

CHTC

CHTC

CHTC

CHTC

CHTC

CHTC

CHTC

Performance

Cross Top Cover

Remarks

* Thickness is minimum recommended as per TMI manufacturing standard.

* Heights available are standard, other heights are available as special request.

* Standard Couplers size is 100 mm x side height of Trunking.

* Standard Hardware M6 Bolts for Cable Tray with M8 Nuts and Washer.

* Model represents the MTN type. Other anges available upon request as per below.

   H   E   I   G   H   T

S   L  O  T    1  2  x  7   

   T   H   I  C   K   N

   E   S   S

WIDTH

    L   i  g   h   t   D  u   t  y   i  s   1 .   0

   /   1 .   2  m  m    T

   h   i  c   k  n  e  s  s

    M  e   d   i  u  m    D

  u   t  y   i  s   1 .   5  m  m    T

   h   i  c   k  n  e  s  s

    H  e  a  v  y   D  u   t  y   i  s   2 .   0

   /   2 .   5  m  m    T

   h   i  c   k  n  e  s  s

STN Type DTN Type MTN Type

GI

GI

GI

GI

GI

GI

GI

GI

S te el T yp e T ra y Ty pe A cc es so ry

1.0

1.0

1.2

1.5

1.5

1.5

2.0

2.0

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

Thickness mm Length mmHeightmmWidth mm

  50

75 /50 

50/100

50/100/150

50/100/150

50/100/150

50/100/150

50/100/150

50

75

100

150

200

225

250

300

STN

STN

STN

STN

STN

STN

STN

STN

RS

RS

RS

RS

RS

RS

RS

RS

Performance

Reducer Straight

Remarks

* Thickness is minimum recommended as per TMI  manufacturing standard.

* Heights available are standard, other heights are available as special request.

* Standard Couplers size is 100 mm x side height of Trunking.

* Standard Hardware M6 Bolts for Cable Tray with M8 Nuts and Washer.

* Model represents the MTN type. Other anges available upon request as per below.

50

75

100

150

200

225

250

300

X Y

HEIGHT

THICKNESS

   W   I   D   T   H

   W   I   D   T   H

S LO T  1 2 x 7  

    L   i  g   h   t   D  u   t  y   i  s   1 .   0

   /   1 .   2  m  m    T

   h   i  c   k  n  e  s  s

    M  e

   d   i  u  m    D

  u   t  y   i  s   1 .   5  m  m    T

   h   i  c   k  n  e  s  s

    H  e  a  v  y   D  u   t  y   i  s   2 .   0

   /   2 .   5  m  m    T

   h   i  c   k  n  e  s  s

31

   W   I   D   T   H

STN Type DTN Type MTN Type

GI

GI

GI

GI

GI

GI

GI

GI

S tee lType Tray Type Accessory

1.0

1.0

1.2

1.5

1.5

1.5

2.0

2.0

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

Thickness mm Length mmHeightmmWidth mm

 50

75 /50 

50/100

50/100/150

50/100/150

50/100/150

50/100/150

50/100/150

50

75

100

150

200

225

250

300

STN

STN

STN

STN

STN

STN

STN

STN

CTIC

CTIC

CTIC

CTIC

CTIC

CTIC

CTIC

CTIC

Performance

Ply Mouth

Remarks

* Thickness is minimum recommended as per TMI manufacturing standard.

* Heights available are standard, other heights are available as special request.

* Standard Couplers size is 100 mm x side height of Trunking.

* Standard Hardware M6 Bolts for Cable Tray with M8 Nuts and Washer.

* Model represents the MTN type. Other anges available upon request as per below.   S   L   O   T   1   2  x   7

HEIGHT

   T   H   I   C   K   N   E   S   S

   W   I   D   T   H

    L   i  g   h   t   D  u   t  y   i  s   1 .   0

   /   1 .   2  m  m    T

   h   i  c   k  n  e  s  s

    M  e   d   i  u  m    D

  u   t  y   i  s   1 .   5  m  m    T

   h   i  c   k  n  e  s  s

    H  e  a  v  y   D  u   t  y   i  s   2 .   0

   /   2 .   5  m  m    T

   h   i  c   k  n  e  s  s

STN Type DTN Type MTN Type

GI

GI

GI

GI

GI

GI

GI

GI

S te el T yp e T ra y Ty pe A cc es so ry

1.0

1.0

1.2

1.5

1.5

1.5

2.0

2.0

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

Thickness mm Length mmHeightmmWidth mm

  50

75 /50

50/100

50/100/150

50/100/150

50/100/150

50/100/150

50/100/150

50

75

100

150

200

225

250

300

STN

STN

STN

STN

STN

STN

STN

STN

CTOC

CTOC

CTOC

CTOC

CTOC

CTOC

CTOC

CTOC

Performance

Tee Outside Cover

Remarks

* Thickness is minimum recommended as per TMI manufacturing standard.

* Heights available are standard, other heights are available as special request.

* Standard Couplers size is 100 mm x side height of Trunking.

* Standard Hardware M6 Bolts for Cable Tray with M8 Nuts and Washer.

* Model represents the MTN type. Other anges available upon request as per below.

HEIGHT

   T

   H   I   C   K   N   E   S   S

   W   I   D   T   H

    L   i  g   h   t   D  u   t  y   i  s   1 .   0

   /   1 .   2  m  m    T

   h   i  c   k  n  e  s  s

    M  e

   d   i  u  m    D

  u   t  y   i  s   1 .   5  m  m    T

   h   i  c   k  n  e  s  s

    H  e  a  v  y   D  u   t  y   i  s   2 .   0

   /   2 .   5  m  m    T

   h   i  c   k  n  e  s  s

32

Page 24: Cable Management System

8/9/2019 Cable Management System

http://slidepdf.com/reader/full/cable-management-system 24/44

Cable Basket System Overview

Reducer Left

Cross Horizontal

Tee Horizontal

Offset horizontal Up

Bend 450

Reducer Straight

Internal Riser

Bend 900

Straight Cable Basket

External Riser

Offset horizontal Down

33

Reducer RIght

34

Page 25: Cable Management System

8/9/2019 Cable Management System

http://slidepdf.com/reader/full/cable-management-system 25/44

Cable Basket Sraight

Construction Drawing

4.5

4.5

5.0

HD/GI/SS4/SS6/SS6L/ZN

HD/GI/SS4/SS6/SS6L/ZN

HD/GI/SS4/SS6/SS6L/ZN

Steel Type Tray Type Height mm Wire Diameter mm Length mmWidth mm

30

30

30

3000

3000

3000

150

200

300

CB

CB

CB

Height 30

4.0

4.0

4.0

4.5

5.0

5.0

5.0

5.0

HD/GI/SS4/SS6/SS6L/ZN

HD/GI/SS4/SS6/SS6L/ZN

 HD/GI/SS4/SS6/SS6L/ZN

HD/GI/SS4/SS6/SS6L/ZN

 HD/GI/SS4/SS6/SS6L/ZN

HD/GI/SS4/SS6/SS6L/ZN

HD/GI/SS4/SS6/SS6L/ZN

HD/GI/SS4/SS6/SS6L/ZN

Steel Type Tray Type Height mm Wire Diameter mm Length mmWidth mm

  55

55

55

55

55

55

55

55

3000

3000

3000

3000

3000

3000

3000

3000

100

150

200

300

400

450

500

600

CB

CB

CB

CB

CB

CB

CB

CB

Height 55

4.0

4.0

4.5

5.0

5.0

5.0

HD/GI/SS4/SS6/SS6L/ZN

HD/GI/SS4/SS6/SS6L/ZN

 HD/GI/SS4/SS6/SS6L/ZN

HD/GI/SS4/SS6/SS6L/ZN

 HD/GI/SS4/SS6/SS6L/ZN

HD/GI/SS4/SS6/SS6L/ZN

Steel Type Tray Type Height mm Wire Diameter mm Length mmWidth mm

100

100

  100

  100

  100

100

3000

3000

3000

3000

3000

3000

100

200

300

400

500

600

CB

CB

CB

CB

CB

CB

Height 100

CB-HD-I-300-55-4-3000

Material Type

•Cable Basket

Finishing

• HDG

• GI

• ZN

C.B TYPE• Height 30

• Height 55

• Height 100

Length ofBasket

Wire Diameter

Side Height

Width

35 36

Cable Basket Straight - Ordering Guide (CB)

Page 26: Cable Management System

8/9/2019 Cable Management System

http://slidepdf.com/reader/full/cable-management-system 26/44

Cable Basket-Fittings

Remarks

* The Tee horizontal is made by two straight cable basket sections.

* It is joined by couplers and brackets and available in kits along with the straight sections.

* All width available according to the straight section (100 mm upto 600 mm).

Tee Horizontal

Remarks

* The cross horizontal is made by two straight cable basket sections.

* It is joined by couplers and brackets and available in kits along with the straight sections.

* All width available according to the straight section. (50 mm upto 600 mm).

Cross Horizontal

37

Remarks

* The elbow horizontal 450 is made by two straight cable basket sections.

* It is joined by couplers and brackets and available in kits along with the straight sections.

* All width available according to the straight section (100 mm upto 600 mm).

Elbow Horizontal 450

Remarks

* The elbow horizontal 900 is made by two straight cable basket sections.

* It is joined by couplers and brackets and available in kits along with the straight sections.

* All width available according to the straight section (100 mm upto 600 mm).

Elbow Horizontal 900

38

The Cable Basket Straight Sections along with couplers and hardwares will be supplied to clients as per speci-

cation required.

Fittings will be fabricated on site by clients in accordance with drawings below.

Page 27: Cable Management System

8/9/2019 Cable Management System

http://slidepdf.com/reader/full/cable-management-system 27/44

39 40

Remarks

* The reducer right is made by two straight cable basket sections.

* It is joined by couplers and brackets and available in kits along with the straight sections.

* All width available according to the straight section (100 mm upto 600 mm).

Reducer Right

Remarks

* The reducer left is made by two straight cable basket sections.

* It is joined by couplers and brackets and available in kits along with the straight sections.

* All width available according to the straight section (100 mm upto 600 mm).

Reducer LeftReducer Straight

Remarks

* The reducer straight is made by two straight cable basket sections.

* It is joined by couplers and brackets and available in kits along with the straight sections.

* All width available according to the straight section (100 mm upto 600 mm).

Remarks

* The external riser is made by one straight cable basket sections.

* It is joined by couplers and brackets and available in kits along with the straight sections.

* All width available according to the straight section (100 mm upto 600 mm).

External Riser

Page 28: Cable Management System

8/9/2019 Cable Management System

http://slidepdf.com/reader/full/cable-management-system 28/44

41 42

Remarks

* The offset horizontal up is made by one straight cable basket sections.

* It is joined by couplers and brackets and available in kits along with the straight sections.

* All width available according to the straight section (100 mm upto 600 mm).

Offset Horizontal Up

Remarks

* The internal is made by one straight cable basket sections.

* It is joined by couplers and brackets and available in kits along with the straight sections.

* All width available according to the straight section (100 mm upto 600 mm).

Internal Riser

Remarks

* The offset horizontal down is made by one straight cable basket sections.

* It is joined by couplers and brackets and available in kits along with the straight sections.

* All width available according to the straight section (100 mm upto 600 mm).

Offset Horizontal Down

Page 29: Cable Management System

8/9/2019 Cable Management System

http://slidepdf.com/reader/full/cable-management-system 29/44

Metal Framing Systems - Covers - Accessories - Hardware

Page 30: Cable Management System

8/9/2019 Cable Management System

http://slidepdf.com/reader/full/cable-management-system 30/44

Metal Framing Systems

GI/HD/AL

S te el Ty pe Ma ter ia l Ty pe

1 . 5/ 2 .0 / 2. 5 3 0 00 / 6 00 0

Thickness mm Length mmHeightmmWidth mm

2141CS   P21

Plain Type 21

Remarks

* Thickness is minimum recommended as per TMI manufacturing standard.

GI/HD/AL

S te el Ty pe Ma ter ia l Ty pe

1 . 5/ 2 .0 / 2. 5 3 0 00 / 6 00 0

Thickness mm Length mmHeightmmWidth mm

4141CS   P41

Plain Type 41

Remarks

* Thickness is minimum recommended as per TMI manufacturing standard.

GI/HD/AL

St ee lTy pe M ate ri al Ty pe

1 . 5/ 2 .0 / 2 .5 3 0 0 0/ 6 00 0

Thickness mm Length mmHeightmmWidth mm

4241CS   DP21

Double Plain Type 21

Remarks

* Thickness is minimum recommended as per TMI  manufacturing standard.

GI/HD/AL

St ee lTy pe M ate ri al Ty pe

1 . 5/ 2 .0 / 2 .5 3 0 0 0/ 6 00 0

Thickness mm Length mmHeightmmWidth mm

8241CS   DP41

Double Plain Type 41

Remarks

* Thickness is minimum recommended as per TMI  manufacturing standard.

GI/HD/AL

St ee lTy pe M ate ri al Ty pe

1 . 5/ 2 .0 / 2 .5 3 0 0 0/ 6 00 0

Thickness mm Length mmHeightmmWidth mm

2141CS   S21

Slotted Type 21

Remarks

* Thickness is minimum recommended as per TMI  manufacturing standard.

GI/HD/AL

St ee lTy pe M ate ri al Ty pe

1 . 5/ 2 .0 / 2 .5 3 0 0 0/ 6 00 0

Thickness mm Length mmHeightmmWidth mm

4141CS   S41

Slotted Type 41

Remarks

* Thickness is minimum recommended as per TMI manufacturing standard.

GI/HD/AL

S te el Typ e Ma ter ia l Ty pe

1 . 5 /2 . 0/ 2 .5 3 0 00 / 6 00 0

Thickness mm Length mmHeightmmWidth mm

4241CS   DS21

Double Slotted Type 21

Remarks

* Thickness is minimum recommended as per TMI manufacturing standard.

GI/HD/AL

S te el T yp e M at er ia l Type

1 . 5 /2 . 0/ 2 .5 3 0 00 / 6 00 0

Thickness mm Length mmHeightmmWidth mm

8241CS   DS41

Double Slotted Type 41

Remarks

* Thickness is minimum recommended as per TMI manufacturing standard.

43 44

Page 31: Cable Management System

8/9/2019 Cable Management System

http://slidepdf.com/reader/full/cable-management-system 31/44

45 46

50

75

100

150

200

225

250

300

400

450

500

600

750

800

900

1050

1200

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

Steel Type Accessory WidthLength of CantileverArm

100

125

150

200

250

275

325

350

450

500

550

650

800

850

950

1100

1250

CACT

CACT

CACT

CACT

CACT

CACT

CACT

CACT

CACT

CACT

CACT

CACT

CACT

CACT

CACT

CACT

CACT

Cantilever Arm Cable Tray

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

Steel Type Accessory WidthLength of CantileverArm

100

125

150

200

250

275

325

350

450

500

550

650

800

850

950

1100

1250

CAPSC

CAPSC

CAPSC

CAPSC

CAPSC

CAPSC

CAPSC

CAPSC

CAPSC

CAPSC

CAPSC

CAPSC

CAPSC

CAPSC

CAPSC

CAPSC

CAPSC

Cantilever Arm Plain Single Channel

50

75

100

150

200

225

250

300

400

450

500

600

750

800

900

1050

1200

Remarks

* Base post Thickness is 6 mm.

* Other thickness avilable upon request.

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

Steel Type Accessory WidthLength of CantileverArm

100

125

150

200

250

275

325

350

450

500

550

650

800

850

950

1100

1250

CASSC

CASSC

CASSC

CASSC

CASSC

CASSC

CASSC

CASSC

CASSC

CASSC

CASSC

CASSC

CASSC

CASSC

CASSC

CASSC

CASSC

Cantilever Arm Slotted Single Channel

50

75

100

150

200

225

250

300

400

450

500

600

750

800

900

1050

1200

Remarks

* Base post Thickness is 6 mm.

* Other thickness avilable upon request.

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

Steel Type Accessory WidthLength of CantileverArm

100

125

150

200

250

275

325

350

450

500

550

650

800

850

950

1100

1250

CASDC

CASDC

CASDC

CASDC

CASDC

CASDC

CASDC

CASDC

CASDC

CASDC

CASDC

CASDC

CASDC

CASDC

CASDC

CASDC

CASDC

Cantilever Arm Slotted Double Channel

50

75

100

150

200

225

250

300

400

450

500

600

750

800

900

1050

1200

Remarks

* Base post Thickness is 6 mm.

* Other thickness avilable upon request.

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6LHD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

Steel Type Accessory WidthLength of CantileverArm

100

125

150

200

250275

325

350

450

500

550

650

800

850

950

1100

1250

CAPDC

CAPDC

CAPDC

CAPDC

CAPDCCAPDC

CAPDC

CAPDC

CAPDC

CAPDC

CAPDC

CAPDC

CAPDC

CAPDC

CAPDC

CAPDC

CAPDC

Cantilever Arm Plain Double Channel

50

75

100

150

200225

250

300

400

450

500

600

750

800

900

1050

1200

Remarks

* Base post Thickness is 6 mm.

* Other thickness avilable upon request.

Ordering Guide - Metal Framing Systrem

Finishing • HDG

• GI

• AL

Accessory • 21• 41• 42 (D)• 82 (D)

CASDC-HD-41-450-6

Steel Thickness

Length of C.A

CACT•CAPSC

•CASSC

•CAPDC

•CASDC

Material Type

Page 32: Cable Management System

8/9/2019 Cable Management System

http://slidepdf.com/reader/full/cable-management-system 32/44

Post Bases & I- Beam Support

PB - 101 Base post 2 holes

PB - 102 Base post 2 holes

PB - 103 Base post 2 holes double channel

PB - 104 Base post 2 holesdouble channel

HD/GI/SS4/SS6/SS6L

Steel Type Type

BP2H-101

Remarks

* Manufacturing standard Base steel thickness is 6mm.

* Base plate steel other thicknesses available upon request.

HD/GI/SS4/SS6/SS6L

SteelType Type

BP2H-102

Remarks

* Manufacturing standard Base steel thickness is 6mm.

* Base plate steel other thicknesses available upon request.

HD/GI/SS4/SS6/SS6L

Steel Type Type

BPD2H-103

Remarks

* Manufacturing standard Base steel thickness is 6mm.

* Base plate steel other thicknesses available upon request.

HD/GI/SS4/SS6/SS6L

Steel Type Type

BPD2H-104

Remarks

* Manufacturing standard Base steel thickness is 6mm.

* Base plate steel other thicknesses available upon request.

47

PB - 106 Base post 4 holes

HD/GI/SS4/SS6/SS6L

Steel Type Type

BP4H-105

Remarks

* Manufacturing standard Base steel thickness is 6mm.

* Base plate steel other thicknesses available upon request.

PB - 107 Base post 4 holes

HD/GI/SS4/SS6/SS6L

SteelType Type

BP4H-106

Remarks

* Manufacturing standard Base steel thickness is 6mm.

* Base plate steel other thicknesses available upon request.

PB - 108 Base post 4 holes double channel

HD/GI/SS4/SS6/SS6L

Steel Type Type

BPD4H-107

Remarks

* Manufacturing standard Base steel thickness is 6mm.

* Base plate steel other thicknesses available upon request.

PB - 105 Base post 4 holes

HD/GI/SS4/SS6/SS6L

Steel Type Type

BPD4H-108

Remarks

* Manufacturing standard Base steel thickness is 6mm.

* Base plate steel other thicknesses available upon request.

48

Page 33: Cable Management System

8/9/2019 Cable Management System

http://slidepdf.com/reader/full/cable-management-system 33/44

HD/GI/SS4/SS6/SS6L

Steel Type Type Size

M6/M8/M10/M12SSF105

Remarks

* Manufacturing standard of Strut Fittings in accordance with above table, Thickness is 6mm.

* Other sizes available upon request.

SF - 105 U-connector DSP

Struts Fittings

SF - 101 Square Washer

HD/GI/SS4/SS6/SS6L

Steel Type Type Size

M6/M8/M10/M12SSF101

Remarks

* Manufacturing standard of Strut Fittings in accordance with above table, Thickness is 6mm.

* Other sizes available upon request.

SF - 102 Double hole splice plate

HD/GI/SS4/SS6/SS6L

Steel Type Type Size

M6/M8/M10/M12SSF102

Remarks

* Manufacturing standard of Strut Fittings in accordance with above table, Thickness is 6mm.

* Other sizes available upon request.

SF - 103 Triple hole splice plate

HD/GI/SS4/SS6/SS6L

Steel Type Type Size

M6/M8/M10/M12SSF103

Remarks

* Manufacturing standard of Strut Fittings in accordance with above table, Thickness is 6mm.

* Other sizes available upon request.

SF - 104 4 hole splice plate

HD/GI/SS4/SS6/SS6L

SteelType Type Size

M6/M8/M10/M12SSF104

Remarks

* Manufacturing standard of Strut Fittings in accordance with above table, Thickness is 6mm.

* Other sizes available upon request.

49

SF - 107 Corner plate

HD/GI/SS4/SS6/SS6L

Steel Type Type Size

M6/M8/M10/M12SSF107

Remarks

* Manufacturing standard of Strut Fittings in accordance with above table, Thickness is 6mm.

* Other sizes available upon request.

SF - 108 Tee plate

HD/GI/SS4/SS6/SS6L

Steel Type Type Size

M6/M8/M10/M12SSF108

Remarks

* Manufacturing standard of Strut Fittings in accordance with above table, Thickness is 6mm.

* Other sizes available upon request.

SF - 109 Cross plate

HD/GI/SS4/SS6/SS6L

Steel Type Type Size

M6/M8/M10/M12SSF109

Remarks

* Manufacturing standard of Strut Fittings in accordance with above table, Thickness is 6mm.

* Other sizes available upon request.

SF - 110 Gusset plate corner

HD/GI/SS4/SS6/SS6L

SteelType Type Size

M6/M8/M10/M12SSF110

Remarks

* Manufacturing standard of Strut Fittings in accordance with above table, Thickness is 6mm.

* Other sizes available upon request.

50

SF - 106 U-connector

HD/GI/SS4/SS6/SS6L

Steel Type Type Size

M6/M8/M10/M12SSF106

Remarks

* Manufacturing standard of Strut Fittings in accordance with above table, Thickness is 6mm.

* Other sizes available upon request.

Page 34: Cable Management System

8/9/2019 Cable Management System

http://slidepdf.com/reader/full/cable-management-system 34/44

HD/GI/SS4/SS6/SS6L

Steel Type Type Size

M6/M8/M10/M12SSF112

Remarks

* Manufacturing standard of Strut Fittings in accordance with above table, Thickness is 6mm.

* Other sizes available upon request.

SF - 112 Corner angle 2 holes

HD/GI/SS4/SS6/SS6L

Steel Type Type Size

M6/M8/M10/M12SSF114

Remarks

* Manufacturing standard of Strut Fittings in accordance with above table, Thickness is 6mm.

* Other sizes available upon request.

SF - 114 Corner angle 4 holes

HD/GI/SS4/SS6/SS6L

Steel Type Type Size

M6/M8/M10/M12SSF115

Remarks

* Manufacturing standard of Strut Fittings in accordance with above table, Thickness is 6mm.

* Other sizes available upon request.

SF -115 Beam clamp type

HD/GI/SS4/SS6/SS6L

Steel Type Type Size

M6/M8/M10/M12SSF116

Remarks

* Manufacturing standard of Strut Fittings in accordance with above table, Thickness is 6mm.

* Other sizes available upon request.

SF - 116 Beam clamp

HD/GI/SS4/SS6/SS6L

Steel Type Type Size

M6/M8/M10/M12SSF113

Remarks

* Manufacturing standard of Strut Fittings in accordance with above table, Thickness is 6mm.

* Other sizes available upon request.

SF - 113 Corner angle 3 hole

51

HD/GI/SS4/SS6/SS6L

Steel Type Type Size

M6/M8/M10/M12SSF117

Remarks

* Manufacturing standard of Strut Fittings in accordance with above table, Thickness is 6mm.

* Other sizes available upon request.

SF -117 Universal bracket

HD/GI/SS4/SS6/SS6L

Steel Type Type Size

M6/M8/M10/M12SSF118

Remarks

* Manufacturing standard of Strut Fittings in accordance with above table, Thickness is 6mm.

* Other sizes available upon request.

SF - 118 Bend angle bracket

HD/GI/SS4/SS6/SS6L

Steel Type Type Size

M6/M8/M10/M12SSF119

Remarks

* Manufacturing standard of Strut Fittings in accordance with above table, Thickness is 6mm.

* Other sizes available upon request.

SF - 119 Tee angle

HD/GI/SS4/SS6/SS6L

Steel Type Type Size

M6/M8/M10/M12SSF120

Remarks

* Manufacturing standard of Strut Fittings in accordance with above table, Thickness is 6mm.

* Other sizes available upon request.

SF - 120 Gusset angle bracket

52

SF - 111 Gusset plate tee

HD/GI/SS4/SS6/SS6L

Steel Type Type Size

M6/M8/M10/M12SSF111

Remarks

* Manufacturing standard of Strut Fittings in accordance with above table, Thickness is 6mm.

* Other sizes available upon request.

Page 35: Cable Management System

8/9/2019 Cable Management System

http://slidepdf.com/reader/full/cable-management-system 35/44

SF - 121 Corner connection right hand

HD/GI/SS4/SS6/SS6L

Steel Type Type Size

M6/M8/M10/M12SSF121

Remarks

* Manufacturing standard of Strut Fittings in accordance with above table, Thickness is 6mm.

* Other sizes available upon request.

SF - 122 Corner connection left hand

HD/GI/SS4/SS6/SS6L

Steel Type Type Size

M6/M8/M10/M12SSF122

Remarks

* Manufacturing standard of Strut Fittings in accordance with above table, Thickness is 6mm.

* Other sizes available upon request.

SF - 123 U-clamp-21

HD/GI/SS4/SS6/SS6L

SteelType Type Size

M6/M8/M10/M12SSF123

Remarks

* Manufacturing standard of Strut Fittings in accordance with above table, Thickness is 6mm.

* Other sizes available upon request.

SF - 124 U-clamp-41

HD/GI/SS4/SS6/SS6L

Steel Type Type Size

M6/M8/M10/M12SSF124

Remarks

* Manufacturing standard of Strut Fittings in accordance with above table, Thickness is 6mm.

* Other sizes available upon request.

SF - 125 U-clamp-DSP

HD/GI/SS4/SS6/SS6L

Steel Type Type Size

M6/M8/M10/M12SSF125

Remarks

* Manufacturing standard of Strut Fittings in accordance with above table, Thickness is 6mm.

* Other sizes available upon request.

53

SF - 126 Strut connector

HD/GI/SS4/SS6/SS6L

SteelType Type Size

M6/M8/M10/M12SSF126

Remarks

* Manufacturing standard of Strut Fittings in accordance with above table, Thickness is 6mm.

* Other sizes available upon request.

* This strut ttings will be slotted (diamension of slot 20 mmx 7 mm).  

SF - 127 Strut connector 90º

HD/GI/SS4/SS6/SS6L

SteelType Type Size

M6/M8/M10/M12SSF127

Remarks

* Manufacturing standard of Strut Fittings in accordance with above table, Thickness is 6mm.

* Other sizes available upon request.

* This strut ttings will be slotted (diamension of slot 20 mmx 7 mm).  

SF - 128 Strut connector tee

HD/GI/SS4/SS6/SS6L

Steel Type Type Size

M6/M8/M10/M12SSF128

Remarks

* Manufacturing standard of Strut Fittings in accordance with above table, Thickness is 6mm.

* Other sizes available upon request.

* This strut ttings will be slotted (diamension of slot 20 mmx 7 mm).  

SF -129 Strut connector cross

HD/GI/SS4/SS6/SS6L

SteelType Type Size

M6/M8/M10/M12SSF129

Remarks

* Manufacturing standard of Strut Fittings in accordance with above table, Thickness is 6mm.

* Other sizes available upon request.

* This strut ttings will be slotted (diamension of slot 20 mmx 7 mm).  

54

Page 36: Cable Management System

8/9/2019 Cable Management System

http://slidepdf.com/reader/full/cable-management-system 36/44

Cable Tray Covers Cable Tray acessories & Connectors

HD/GI/AL/SS4/SS6/SS6L

Steel Type Accessory Type

RCSO/OS/SP/SI

Remarks

* Thickness is minimum recommended as per TMI  manufacturing standard.

Reducing Connector

Straight Divider

Remarks

* Thickness is minimum recommended as per TMI  manufacturing standard.

HD/GI/AL/SS4/SS6/SS6L

Steel Type Accessory Type

SDSO/OS/SP/SI

HD/GI/AL/SS4/SS6/SS6L

Steel Type Accessory Type

DOSO/OS/SP/SI

Drop Out

Remarks

* Thickness is minimum recommended as per TMI manufacturing standard.

HD/GI/AL/SS4/SS6/SS6L

SteelType Accessory Type

FPSO/OS/SP/SI

Fish Plate

Remarks

* Thickness is minimum recommended as per TMI manufacturing standard.

56

Plain Edged Cover (CTPE) Plain Cover (CTPC)

 Ventilated Edged Cover (CTVE) Ventilated Cover (CTVC)

1.0/1.2/1.5/2.0

1.0/1.2/1.5/2.0

1.0/1.2/1.5/2.0

1.0/1.2/1.5/2.0

1.0/1.2/1.5/2.0

1.2/1.5/2.0

1.2/1.5/2.0

1.2/1.5/2.0

1.5/2.0

1.5/2.0

1.5/2.0

1.5/2.0

2.00

2.00

2.00

2.00

2.00

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

Steel Type Cover Type Height mm Thickness mm Length mm PerformanceWidth mm

50 / 30

50 / 30

50 / 30

50 / 30

50 / 30

50 / 30

50 / 30

50 / 30

50 / 30

50 / 30

50 / 30

50 / 30

50 / 30

50 / 30

50 / 30

50 / 30

50 / 30

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000

2440/3000

2440/3000

2440/3000

1200

50

75

100

150

200

225

250

300

400

450

500

600

750

800

900

1050

1200

VE/VC/PE/PC

VE/VC/PE/PC

VE/VC/PE/PC

VE/VC/PE/PC

VE/VC/PE/PC

VE/VC/PE/PC

VE/VC/PE/PC

VE/VC/PE/PC

VE/VC/PE/PC

VE/VC/PE/PC

VE/VC/PE/PC

VE/VC/PE/PC

VE/VC/PE/PC

VE/VC/PE/PC

VE/VC/PE/PC

VE/VC/PE/PC

VE/VC/PE/PC

Remarks

* Thickness is minimum recommended as per TMI  manufacturing standard.

* Heights available are standard, other heights are available as special request.

* Cable Tray Cover Length is TMI manufacturing standard, other Lengths can be provided upon request.

   L   i  g   h   t   D  u   t  y   i  s   1 .   0

   /   1 .   2  m  m    T

   h   i  c   k  n  e  s  s

    M  e   d   i  u  m    D

  u   t  y   i  s   1 .   5  m  m    T

   h   i  c   k  n  e  s

  s

    H  e  a  v  y   D  u   t  y   i  s   2 .   0

   /   2 .   5  m  m    T

   h   i  c   k  n  e

  s  s

Ordering Guide - Cable Tray Covers

Finishing • HDG

• GI

• AL

CTVE-HD-300-30-2-3000

•CTVE

•CTVC

•CTPE

•CTPC

Material Type

Finishing • HDG

• GI

• AL

• SS4

• SS6

• SS6L

Length of Tray

Steel Thickness

Side Height

Width

55

Page 37: Cable Management System

8/9/2019 Cable Management System

http://slidepdf.com/reader/full/cable-management-system 37/44

Cover Clamp

HD/GI/AL/SS4/SS6/SS6L

Steel Type Accessory Type

CCSO/OS/SP/SI

Remarks

* Thickness is minimum recommended as per TMI  manufacturing standard.

Cover Clamp With Screw

HD/GI/AL/SS4/SS6/SS6L

Steel Type Accessory Type

CCSSO/OS/SP/SI

Remarks

* Thickness is minimum recommended as per TMI  manufacturing standard.

Blind End Plate

HD/GI/AL/SS4/SS6/SS6L

Steel Type Accessory Type

BEPSO/OS/SP/SI

Remarks

* Thickness is minimum recommended as per TMI  manufacturing standard.

Dynamic Connector

HD/GI/AL/SS4/SS6/SS6L

Steel Type Accessory Type

DYCSO/OS/SP/SI

Remarks

* Thickness is minimum recommended as per TMI  manufacturing standard.

57

HD/GI/AL/SS4/SS6/SS6L

Steel Type Accessory Type

BJSO/OS/SP/SI

Bonding Jumper

Remarks

* Thickness is minimum recommended as per TMI manufacturing standard.

HD/GI/AL/SS4/SS6/SS6L

Steel Type Material Type

2.0 /1.5 /1.2 / 1.0

Thickness mmHeightmmWidth mm

50/100180SO/OS/SP/SI SC

Remarks

* Thickness is minimum recommended as per TMI  manufacturing standard.

Standard Connector

HD/GI/AL/SS4/SS6/SS6L

Steel Type Material Type

2.0 /1.5 /1.2 / 1.0

Thickness mmHeightmmWidth mm

50/100180S O /O S /S P /S I F G

Remarks

* Thickness is minimum recommended as per TMI manufacturing standard.

Flanged Connector

HD/GI/AL/SS4/SS6/SS6L

Steel Type Material Type

2.0 /1.5 /1.2 / 1.0

Thickness mmHeightmmWidth mm

50/100180SO/OS/SP/SI CSC

Remarks

* Thickness is minimum recommended as per TMI  manufacturing standard.

Angle Standard Connector

HD/GI/AL/SS4/SS6/SS6L

Steel Type Accessory Type

ADCSO/OS/SP/SI

Adjustable Connector

Remarks

* Thickness is minimum recommended as per TMI manufacturing standard.

Bendable Divider

HD/GI/AL/SS4/SS6/SS6L

Steel Type Accessory Type

BDDSO/OS/SP/SI

Remarks

* Thickness is minimum recommended as per TMI  manufacturing standard.

58

Page 38: Cable Management System

8/9/2019 Cable Management System

http://slidepdf.com/reader/full/cable-management-system 38/44

Cable Ladder Covers

59

Cable Ladder accessories & Connectors

Bendable Divider

HD/GI/AL/SS4/SS6/SS6L

Steel Type Accessory Type

BDDNC/OC/OG/Z

Remarks

* Thickness is minimum recommended as per TMI  manufacturing standard.

Drop Out

HD/GI/AL/SS4/SS6/SS6L

Steel Type Accessory Type

DPONC/OC/OG/Z

Remarks

* Thickness is minimum recommended as per TMI  manufacturing standard.

60

Plain Edged Cover (CLPE) Plain Cover (CLPC)

1.0/1.2/1.5/2.0

1.0/1.2/1.5/2.0

1.0/1.2/1.5/2.0

1.0/1.2/1.5/2.0

1.0/1.2/1.5/2.0

1.2/1.5/2.0

1.2/1.5/2.0

1.2/1.5/2.0

1.5/2.0

1.5/2.0

1.5/2.0

1.5/2.0

2.00

2.00

2.00

2.00

2.00

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

HD/GI/AL/SS4/SS6/SS6L

Steel Type Cover Type Height mm Thickness mm Length mm PerformanceWidth mm

 15

 15

 15

 15

 15

 15

 15

 15

 15

 15

 15

 15

 15

 15

 15

 15

 15

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000/6000

2440/3000

2440/3000

2440/3000

2440/3000

1200

50

75

100

150

200

225

250

300

400

450

500

600

750

800

900

1050

1200

VE/VC/PE/PC

VE/VC/PE/PC

VE/VC/PE/PC

VE/VC/PE/PC

VE/VC/PE/PC

VE/VC/PE/PC

VE/VC/PE/PC

VE/VC/PE/PC

VE/VC/PE/PC

VE/VC/PE/PC

VE/VC/PE/PC

VE/VC/PE/PC

VE/VC/PE/PC

VE/VC/PE/PC

VE/VC/PE/PC

VE/VC/PE/PC

VE/VC/PE/PC

 Ventilated Edged Cover (CLVE) Ventilated Cover (CLVC)

Remarks

* Thickness is minimum recommended as per TMI  manufacturing standard.

* Heights available are standard, other heights are available as special request.

* Cable Tray Cover Length is TMI manufacturing standard, other Lengths can be provided upon request.

   L   i  g   h   t   D  u   t  y   i  s   1 .   0

   /   1 .   2  m  m    T

   h   i  c   k  n  e  s  s

    M  e   d   i  u  m    D

  u   t  y   i  s   1 .   5  m  m    T

   h   i  c   k  n  e  s  s

    H  e  a  v  y   D  u   t  y   i  s   2 .   0

   /   2 .   5  m  m    T

   h   i  c

   k  n  e  s  s

Ordering Guide - Cable Ladder Covers

Finishing • HDG

• GI

• AL

CLVE-HD-300-30-2-3000

•CRVE

•CRVC•CRPE

•CRPC

Material Type

Finishing • HDG

• GI

• AL

• SS4

• SS6

• SS6L

Length of Tray

Steel Thickness

Side Height

Width

Cover Clamp

HD/GI/AL/SS4/SS6/SS6L

SteelType Accessory Type

CCSO/OS/SP/SI

Remarks

* Thickness is minimum recommended as per TMI manufacturing standard.

Hold Down Clamp

HD/GI/AL/SS4/SS6/SS6L

Steel Type Accessory Type

HDCSO/OS/SP/SI

Remarks

* Thickness is minimum recommended as per TMI  manufacturing standard.

Guide Clamp

HD/GI/AL/SS4/SS6/SS6L

Steel Type Accessory Type

GCSO/OS/SP/SI

Remarks

* Thickness is minimum recommended as per TMI  manufacturing standard.

Page 39: Cable Management System

8/9/2019 Cable Management System

http://slidepdf.com/reader/full/cable-management-system 39/44

HD/GI/AL/SS4/SS6/SS6L

Steel Type Accessory Type

BJNC/OC/OG/Z

Bonding Jumper

Remarks

* Thickness is minimum recommended as per TMI manufacturing standard.

61

HD/GI/AL/SS4/SS6/SS6L

Steel Type Accessory Type

ADCNC/OC/OG/Z

Adjustable Connector

Remarks

* Thickness is minimum recommended as per TMI manufacturing standard.

HD/GI/AL/SS4/SS6/SS6L

Steel Type Material Type

2.0 /1.5 /1.2 / 1.0

Thickness mmHeightmmWidth mm

50/100180SO/OS/SP/SI SC

Remarks

* Thickness is minimum recommended as per TMI manufacturing standard.

Standard Connector

HD/GI/AL/SS4/SS6/SS6L

Steel Type Material Type

2.0 /1.5 /1.2 / 1.0

Thickness mmHeightmmWidth mm

50/100180SO/OS/SP/SI SC

Remarks

* Thickness is minimum recommended as per TMI manufacturing standard.

Expansion Connector

Blind Endplate

HD/GI/AL/SS4/SS6/SS6L

Steel Type Accessory Type

BEPNC/OC/OG/Z

Remarks

* Thickness is minimum recommended as per TMI manufacturing standard.

Dynamic Connector

HD/GI/AL/SS4/SS6/SS6L

Steel Type Accessory Type

DYCNC/OC/OG/Z

Remarks

* Thickness is minimum recommended as per TMI  manufacturing standard.

62

Double Cover Clamp

HD/GI/AL/SS4/SS6/SS6L

Steel Type Accessory Type

DCCNC/OC/OG/Z

Remarks

* Thickness is minimum recommended as per TMI manufacturing standard.

Page 40: Cable Management System

8/9/2019 Cable Management System

http://slidepdf.com/reader/full/cable-management-system 40/44

GI/HD/AL/SS4

SteelType Accessory Type

SCSTN/DTN/MTN

Remarks

* Thickness is minimum recommended as per TMI manufacturing standard.

Standard Coupler

Cable Trunking accessories & Connectors

Blind End

GI/HD/AL/SS4

Steel Type Accessory Type

BNSTN/DTN/MTN

Remarks

* Thickness is minimum recommended as per TMI manufacturing standard.

GI/HD/AL/SS4

Steel Type Accessory Type

BCSTN/DTN/MTN

Remarks

* Thickness is minimum recommended as per TMI manufacturing standard.

Box Connector

GI/HD/AL/SS4

Steel Type Accessory Type

HANSTN/DTN/MTN

Remarks

* Thickness is minimum recommended as per TMI manufacturing standard.

Hanger

GI/HD/AL/SS4

Steel Type Accessory Type

PRSTN/DTN/MTN

Remarks

* Thickness is minimum recommended as per TMI manufacturing standard.

Pin Racks

63

GI/HD/AL/SS4

Steel Type Accessory Type

WRCSTN/DTN/MTN

Remarks

* Thickness is minimum recommended as per TMI  manufacturing standard.

Wrap around Connector

GI/HD/AL/SS4

SteelType Accessory Type

SEPSTN/DTN/MTN

Remarks

* Thickness is minimum recommended as per TMI manufacturin g standard. `

Separator

64

GI/HD/AL/SS4

Steel Type Accessory Type

OSVSTN/DTN/MTN

Remarks

* Thickness is minimum recommended as per TMI manufacturing standard.

Offset Vertical

Offset Horizontal

GI/HD/AL/SS4

Steel Type Accessory Type

OSHSTN/DTN/MTN

Remarks* Thickness is minimum recommended as per TMI manufacturing standard.

THICKNESS

WIDTH

   H   E   I   G   H   T

Page 41: Cable Management System

8/9/2019 Cable Management System

http://slidepdf.com/reader/full/cable-management-system 41/44

Cable Basket accessories & Connectors

Cable Basket Covers

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

Steel Type Accessory Length mmCoverType

CO

CO

CO

CO

CO

CO

CO

CO

CO

CO

CO

CB

CB

CB

CB

CB

CB

CB

CB

CB

CB

CB

3000

3000

3000

3000

3000

3000

3000

3000

3000

3000

3000

Remarks

* Covers are snap-on type

* All Covers are Solid Type

150

200

300

100

150

200

300

400

450

500

600

Width mm

65

Straight Coupler

HD/GI/SS4/SS6/SS6L

Steel Type Accessory Type

SCCB

Remarks

* Thickness is minimum recommended as per TMI  manufacturing standard.SLOT 20x7

900Coupler

HD/GI/SS4/SS6/SS6L

Steel Type Accessory Type

C90CB

Remarks

* Thickness is minimum recommended as per TMI  manufacturing standard.

SLOT 20x7

SLOT 20x7

450Coupler

HD/GI/SS4/SS6/SS6L

Steel Type Accessory Type

C45CB

Remarks

* Thickness is minimum recommended as per TMI  manufacturing standard.

Self Slicing Coupler

HD/GI/SS4/SS6/SS6L

SteelType Accessory Type

SSCCB

Remarks

* Thickness is minimum recommended as per TMI  manufacturing standard.

SLOT 20x7

Reducer Coupler

HD/GI/SS4/SS6/SS6L

Steel Type Accessory Type

FPRC

Remarks

* Thickness is minimum recommended as per TMI  manufacturing standard.

Divider

HD/GI/SS4/SS6/SS6L

Steel Type Accessory Type

DDCB

Remarks

* Thickness is minimum recommended as per TMI  manufacturing standard.

length Wise Hanger

HD/GI/SS4/SS6/SS6L

Steel Type Accessory Type

LHCB

Remarks

* Thickness is minimum recommended as per TMI  manufacturing standard.

  1  5  0

2  5  

 S L O T  2 8 x 9

Width Wise Hanger

HD/GI/SS4/SS6/SS6L

Steel Type Accessory Type

WHCB

Remarks

* Thickness is minimum recommended as per TMI  manufacturing standard.

5  0  

  2  0  0

 S L O T  2 8 x 9

66

Page 42: Cable Management System

8/9/2019 Cable Management System

http://slidepdf.com/reader/full/cable-management-system 42/44

67

Hanger Bracket

HD/GI/SS4/SS6/SS6L

Steel Type Accessory Type

HBCB

Remarks

* Thickness is minimum recommended as per TMI manufacturing standard.

Ø 9

50mm Type 1 Hanger Bracket

HD/GI/SS4/SS6/SS6L

Steel Type Accessory Type

HB50-101CB

Remarks

* Thickness is minimum recommended as per TMI manufacturing standard.

SLOT 28x950mm Type 2 Hanger Bracket

HD/GI/SS4/SS6/SS6L

Steel Type Accessory Type

HB50-102CB

Remarks

* Thickness is minimum recommended as per TMI manufacturing standard.

SLOT 28x9

41x21 Channel

HD/GI/SS4/SS6/SS6L

SteelType Accessory Type

41x21CCB

Remarks

* Thickness is minimum recommended as per TMI manufacturing standard. Ø 9

41x41 Channel

HD/GI/SS4/SS6/SS6L

Steel Type Accessory Type

41x41CCB

Remarks

* Thickness is minimum recommended as per TMI manufacturing standard.

Ø 9

68

 Type 2 Proled Bracket

HD/GI/SS4/SS6/SS6L

Steel Type Accessory Type

PB-102CB

Remarks

* Thickness is minimum recommended as per TMI  manufacturing standard.

Type 3 Proled Bracket

HD/GI/SS4/SS6/SS6L

Steel Type Accessory Type

PB-103

CB

Remarks

* Thickness is minimum recommended as per TMI  manufacturing standard.

Type 4 Proled Bracket

HD/GI/SS4/SS6/SS6L

SteelType Accessory Type

PB-104CB

Remarks

* Thickness is minimum recommended as per TMI  manufacturing standard.

Type 1 Proled Bracket

HD/GI/SS4/SS6/SS6L

Steel Type Accessory Type

PB-101CB

Remarks

* Thickness is minimum recommended as per TMI  manufacturing standard.

Floor Mount & Support Bracket

HD/GI/SS4/SS6/SS6L

Steel Type Accessory Type

FMSB-102CB

Remarks

* Thickness is minimum recommended as per TMI  manufacturing standard.

Page 43: Cable Management System

8/9/2019 Cable Management System

http://slidepdf.com/reader/full/cable-management-system 43/44

HD/GI/SS4/SS6/SS6L

Steel Type Type Accessory

CSB-102CB

Diametermm

20/26

Conduit and Support Bracket 2

Remarks

* Thickness is minimum recommended as per TMI manufacturing standard.

Junction Box Support Bracket

HD/GI/SS4/SS6/SS6L

Steel Type Accessory Accessory

JBSBCB

Remarks

* Thickness is minimum recommended as per TMI manufacturing standard.

HD/GI/SS4/SS6/SS6L

Steel Type Type Accessory

CSB-103CB

Diametermm

20/25

Conduit and Support Bracket 3

Remarks

* Thickness is minimum recommended as per TMI manufacturing standard.

69

Lighting Support Bracket

HD/GI/SS4/SS6/SS6L

Steel Type Accessory Type

LSBCB

Remarks

* Thickness is minimum recommended as per TMI manufacturing standard.

Conduit and Support Bracket 1

Remarks

* Thickness is minimum recommended as per TMI manufacturing standard.

HD/GI/SS4/SS6/SS6L

Steel Type Type Accessory

CSB-101CB

Diametermm

20/25

Ø 20/25

Ø 20

Ø 20

Ø 25

Ø 25

Support System Fasteners

Lock Washer

HD/GI/SS4/SS6/SS6L   M6/M8/M10/M12

Steel Type SizeType

SSF-WALHD/GI/SS4/SS6/SS6L   M8/M10

Steel Type SizeType

SSF-CB

Carrige BoltPlain Washer

HD/GI/SS4/SS6/SS6L   M6/M8/M10/M12

Steel Type SizeType

SSF-WAP

Nylock Nut

HD/GI/SS4/SS6/SS6L   M8/M10

Steel Type SizeType

SSF-NN HD/GI/SS4/SS6/SS6L   M6/M8/M10/M12

Steel Type SizeType

SSF-U

UnixKeps Nut

HD/GI/SS4/SS6/SS6L   M8/M10

Steel Type SizeType

SSF-KN

Long Spring Nut

HD/GI/SS4/SS6/SS6L   M6/M8/M10/M12

Steel Type SizeType

SSF-LSN HD/GI/SS4/SS6/SS6L   M6/M8/M10/M12

Steel Type SizeType

SSF-SSN

Short Spring Nut

HD/GI/SS4/SS6/SS6L   M6/M8/M10/M12

Steel Type SizeType

SSF-NSN

No Spring Nut

70

Page 44: Cable Management System

8/9/2019 Cable Management System

http://slidepdf.com/reader/full/cable-management-system 44/44

Anchor Bolt

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

M8

M10

M12

Steel Type SizeType

SSF-AB

SSF-AB

SSF-AB

40

50/70/80/100

80/100

 Length mm

Roong Bolt

 HD/GI/SS4/SS6/SS6L

 HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

M6

M8

M10

Steel Type SizeType

SSF-RB

SSF-RB

SSF-RB

12/16/20/25

16/20/25

40

 Length mm

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

HD/GI/SS4/SS6/SS6L

M6

M8

M10

M12

M12

Steel Type SizeType

SSF-HHB

SSF-HHB

SSF-HHB

SSF-HHB

SSF-HHB

12/16/20/25/30/40/60

20/25/30/40

20/25/30/40/50/60/90

40/90

80/100

 Length mm

Hex Head Bolt

Threaded Rod

HD/GI/SS4/SS6/SS6L   M6/M8/M10/M12

Steel Type SizeType

BP2H-101   2/3

 Length m

Threaded Rod Coupler Nut

HD/GI/SS4/SS6/SS6L   M6/M8/M10/M12

Steel Type SizeType

SSF-THRN