Attention: Ms Esther Lee STRUCTURAL DESIGN CERTIFICATE ...€¦ · J2010-0572.004 November 11th...

10
J2010-0572.004 November 11 th 2011 Trina Solar Level 13, Office No. 1315 167 Macquarie Street Sydney NSW 2000 Attention: Ms Esther Lee STRUCTURAL DESIGN CERTIFICATE Project Description: Fixing Centres for Trina Mount II Photovoltaic Mounting System as detailed in Trina Mount II Code Compliance Report (Australia), v1.0 We, Partridge Partners Pty Limited, being professional Structural Engineers within the meaning of the Building Code of Australia, hereby certify that we have reviewed the structural design of the fixing centres for the Trina Mount II Photovoltaic Mounting System as detailed in the tables (Trina Mount II Span Tables, 4 no.) provided in the Trina Mount II Code Compliance Report (Australia)”, v1.0, dated October 31, 2011, and that the calculations used to derive these fixing centres are in accordance with the relevant provisions of the Standard Building Codes, in particular AS/NZS1170.2:2011, and in accordance with accepted engineering practice and principles. This certification is subject to the limitations imposed on the system by the manufacturer and as detailed in the Code Compliance Report. The structural capacities of the system components have been derived by others from testing. This document does not constitute certification of the existing roof structure to which the mounting system is to be fixed. Adequacy of the existing structure should be determined on site by the installer prior to installation. This certificate shall not be construed as relieving the system manufacturer or installer of their responsibilities, liabilities or contractual obligations. Rob O’Reilly BE MIEAust CPEng NPER(Structural) RPEQ For and on Behalf of: Partridge Partners Pty Ltd

Transcript of Attention: Ms Esther Lee STRUCTURAL DESIGN CERTIFICATE ...€¦ · J2010-0572.004 November 11th...

J2010-0572.004

November 11th

2011

Trina Solar

Level 13, Office No. 1315

167 Macquarie Street

Sydney NSW 2000

Attention: Ms Esther Lee

STRUCTURAL DESIGN CERTIFICATE

Project Description: Fixing Centres for Trina Mount II Photovoltaic Mounting

System as detailed in

Trina Mount II Code Compliance Report (Australia), v1.0

We, Partridge Partners Pty Limited, being professional Structural Engineers within the

meaning of the Building Code of Australia, hereby certify that we have reviewed the

structural design of the fixing centres for the Trina Mount II Photovoltaic Mounting

System as detailed in the tables (Trina Mount II Span Tables, 4 no.) provided in the “Trina

Mount II Code Compliance Report (Australia)”, v1.0, dated October 31, 2011, and that the

calculations used to derive these fixing centres are in accordance with the relevant

provisions of the Standard Building Codes, in particular AS/NZS1170.2:2011, and in

accordance with accepted engineering practice and principles.

This certification is subject to the limitations imposed on the system by the manufacturer

and as detailed in the Code Compliance Report. The structural capacities of the system

components have been derived by others from testing. This document does not constitute

certification of the existing roof structure to which the mounting system is to be fixed.

Adequacy of the existing structure should be determined on site by the installer prior to

installation.

This certificate shall not be construed as relieving the system manufacturer or installer of

their responsibilities, liabilities or contractual obligations.

Rob O’Reilly BE MIEAust CPEng NPER(Structural) RPEQ

For and on Behalf of:

Partridge Partners Pty Ltd

October 31, 2011

Trina Mount II Code Compliance Report (Australia)

The attached span tables for Trina Mount II photovoltaic mounting system have been

designed in accordance with the structural requirements of the Australian Standard 1170.2

(AS1170.2:2011).

Trina Mount II consists of Big Feet, Cam Feet, Interlocks, Hybrid Interlocks, and Ground

Lugs that connect the edge frames of photovoltaic modules designed to mate with Trina Mount

II. The system has been analyzed for Trina Mount PV modules with maximum dimensions of

992 mm by 1660 mm. The Leveling Feet may be mounted to the following roof types with the

methods listed:

A. Custom Orb corrugated metal roofing

B. Trimdek metal roofing

• Big Foot mounted to the metal deck and screwed into either wood or metal

battens.

The attached tables define maximum Leveling Foot spacing requirements for a range of

Terrain Categories, Wind Regions, roof zones, and roof pitches. The attachment spacing values

in the tables are calculated based on allowable upward, downward, and lateral load values.

These load values are determined from manufacturer provided test data for independently

manufactured products, first principle calculations, and tests conducted using a calibrated load

cell. The tables are based on the conditions illustrated in the attached sketches and listed

below:

1. Terrain Categories 1, 2, 3, and 4 as defined by AS1170.2:2011.

2. Roof wind zones Interior, Edge 1, Edge 2, and Corner as defined by AS1170.2:2011.

3. Maximum Roof Height is 10 meters and roof pitch is between 0ᵒ (flat) and 45ᵒ

(12:12). See tables for specific slope subsets [0-14ᵒ (flat to 3:12), >14-27ᵒ (>3:12 to

6:12), >27-37ᵒ (>6:12 to 9:12), >37-45ᵒ (>9:12 to 12:12)]. For average roof heights

greater than 10 meters contact Trina Solar for reduced spans.

4. Modules installed in “landscape” orientation have the long sides of the modules

parallel to the battens that run across the roof slope. Modules installed in “portrait”

orientation have the long sides of the modules running perpendicular to the battens

and parallel to the roof slope (see sheet 4). In both module orientations, the Big Feet

and Interlocks are positioned on the module edges that run with the slope of the

roof, perpendicular to the battens.

v1.0

October 31, 2011

5. The Importance Level is 2.

6. Building is not located on a bluff or near the top of a hill (i.e. Topographic Multiplier

= 1.0 per AS1170.2:2011).

7. Direction multiplier is equal to 1.0 (i.e. any direction).

8. Shielding multiplier is equal to 1.0 (i.e. no shielding).

9. The bottom of the “Rockit” is a maximum of 25mm above the top of the leveling

foot as shown on sheet 5.

10. The tables apply to roofs with Custom Orb or Trimdek metal roofing and wood or

metal battens.

11. Timber battens must have a minimum thickness of 35mm and be from joint group J4

or better. Steel battens must have a minimum thickness of 0.75mm and be Grade

550 or better.

12. Fasteners are always located at the crest of the roof sheet.

13. For timber battens, use 6.3mm diameter 14G timber screws with a minimum

embedment of 35mm. For steel battens use 6.3mm diameter 14G steel or Tek

screws.

14. EPDM pads or equivalent method shall be installed between the roof cladding and

the Big Foot to assist in waterproofing and provide galvanic separation.

15. Installer is responsible for verifying that all assumptions and limitations are met

when applying the attached foot spacing tables.

16. Conditions outside the assumptions and limitations listed and illustrated for the

attached tables may be feasible, but shall be designed in consultation with Trina

Solar, and, where appropriate, reviewed by a licensed professional engineer. Refer

to the Trina Solar online design tool (trinamount-design.com) for additional design

parameters.

17. If attachments are made to every batten, the existing framing shall be deemed to be

adequate to support that additional loading of the PV system. If battens are skipped,

the installer shall determine the requirement to engage a structural engineer to

determine the adequacy of the existing framing to support the additional loading

due to skipping battens.

v1.0

v1.0

v1.0

v1.0

Roof Zone Interior Edge 1 Edge 2 Corner Interior Edge 1 Edge 2 Corner Interior Edge 1 Edge 2 Corner Interior Edge 1 Edge 2 Corner

Terrain Category

1 1800 1550 1100 N/A 1800 1280 950 N/A 1300 850 N/A N/A 790 320 N/A N/A

2 1800 1800 1470 740 1800 1620 1200 620 1640 1080 770 N/A 1000 660 N/A N/A

2.5 1800 1800 1700 1100 1800 1800 1440 950 1800 1300 960 N/A 1200 790 590 N/A

3 1800 1800 1800 1420 1800 1800 1760 1160 1800 1590 1180 700 1470 970 720 N/A

4 1800 1800 1800 1690 1800 1800 1800 1430 1800 1800 1450 960 1800 1190 890 590

1 1800 1760 1370 1370 1800 1510 1120 920 1540 1010 630 630 940 620 N/A N/A

2 1800 1800 1690 1680 1800 1800 1420 1150 1800 1280 950 790 1190 780 580 490

2.5 1800 1800 1800 1800 1800 1800 1710 1360 1800 1530 1140 940 1420 940 700 590

3 1800 1800 1800 1800 1800 1800 1800 1640 1800 1800 1390 1130 1740 1150 850 710

4 1800 1800 1800 1800 1800 1800 1800 1800 1800 1800 1720 1370 1800 1410 1050 870

1 1800 1760 1370 1370 1800 1510 1120 930 1540 1010 630 630 940 620 N/A N/A

2 1800 1800 1690 1680 1800 1800 1420 1150 1800 1280 950 790 1190 780 580 490

2.5 1800 1800 1800 1800 1800 1800 1710 1370 1800 1530 1140 940 1420 940 700 590

3 1800 1800 1800 1800 1800 1800 1800 1650 1800 1800 1390 1130 1740 1150 850 710

4 1800 1800 1800 1800 1800 1800 1800 1800 1800 1800 1720 1380 1800 1410 1050 870

1 1800 1760 1370 1250 1800 1510 1120 830 1540 1010 630 550 940 620 N/A N/A

2 1800 1800 1690 1550 1800 1800 1420 1030 1800 1280 950 700 1190 780 580 440

2.5 1800 1800 1800 1740 1800 1800 1710 1230 1800 1530 1140 840 1420 940 700 520

3 1800 1800 1800 1800 1800 1800 1800 1480 1800 1800 1390 1010 1740 1150 850 630

4 1800 1800 1800 1800 1800 1800 1800 1800 1800 1800 1720 1230 1800 1410 1050 770

1 1800 1240 920 610 1160 760 560 370 770 510 380 250 470 310 230 N/A

2 1800 1580 1170 760 1470 960 710 470 980 640 480 310 600 390 290 190

2.5 1800 1800 1410 920 1780 1160 860 560 1180 770 570 380 710 470 350 230

3 1800 1800 1730 1130 1800 1420 1050 690 1440 940 700 460 880 580 430 280

4 1800 1800 1800 1390 1800 1760 1300 850 1790 1170 860 570 1080 710 530 350

1 1800 1480 1090 860 1380 900 670 550 910 600 450 370 560 370 270 230

2 1800 1800 1390 1070 1750 1140 850 680 1160 760 560 470 700 460 350 290

2.5 1800 1800 1670 1260 1800 1370 1020 810 1400 910 680 560 850 560 410 350

3 1800 1800 1800 1510 1800 1690 1250 970 1720 1120 830 670 1040 680 510 420

4 1800 1800 1800 1800 1800 1800 1540 1180 1800 1380 1020 820 1280 840 620 510

1 1800 1480 1090 870 1380 900 670 550 910 600 450 380 560 370 270 230

2 1800 1800 1390 1080 1750 1140 850 690 1160 760 560 470 700 460 350 290

2.5 1800 1800 1670 1270 1800 1370 1020 810 1400 910 680 560 850 560 410 350

3 1800 1800 1800 1520 1800 1690 1250 980 1720 1120 830 670 1040 680 510 420

4 1800 1800 1800 1800 1800 1800 1540 1190 1800 1380 1020 820 1280 840 620 520

1 1800 1480 1090 780 1380 900 670 490 910 600 450 330 560 370 270 210

2 1800 1800 1390 970 1750 1140 850 610 1160 760 560 420 700 460 350 260

2.5 1800 1800 1670 1150 1800 1370 1020 730 1400 910 680 500 850 560 410 310

3 1800 1800 1800 1380 1800 1690 1250 880 1720 1120 830 600 1040 680 510 380

4 1800 1800 1800 1670 1800 1800 1540 1070 1800 1380 1020 730 1280 840 620 460

Trina Mount II Span TablesTable 1-- Max Spacing for the Big Foot with 3 Screws into Custom Orb Roofing with Wooden Battens

Module

OrientationRoof Pitch

Wind Region A Wind Region B Wind Region C Wind Region D

>2

7 t

o 3

7

(>6

:12

to

9:1

2)

>3

7 t

o 4

5

(>9

:12

to

12

:12

)

Lan

dsc

ap

e

0 t

o 1

4

de

gre

es

(Fla

t

to 3

:12

)

>1

4 t

o 2

7

(>3

:12

to

6:1

2)

>2

7 t

o 3

7

(>6

:12

to

9:1

2)

>3

7 t

o 4

5

(>9

:12

to

12

:12

)

Po

rtra

it

0 t

o 1

4

de

gre

es

(Fla

t

to 3

:12

)

>1

4 t

o 2

7

(>3

:12

to

6:1

2)

v1.0

Roof Zone Interior Edge 1 Edge 2 Corner Interior Edge 1 Edge 2 Corner Interior Edge 1 Edge 2 Corner Interior Edge 1 Edge 2 Corner

Terrain Category

1 1800 1390 1030 N/A 1300 850 630 N/A 860 570 N/A N/A 530 320 N/A N/A

2 1800 1770 1300 740 1650 1080 800 530 1090 720 530 N/A 670 440 N/A N/A

2.5 1800 1800 1570 1030 1800 1290 960 630 1310 860 640 N/A 800 530 390 N/A

3 1800 1800 1800 1260 1800 1590 1170 770 1610 1060 780 520 980 640 480 N/A

4 1800 1800 1800 1560 1800 1800 1450 950 1800 1300 970 640 1210 790 590 390

1 1800 1650 1220 1220 1540 1010 750 750 1020 670 500 500 620 410 N/A N/A

2 1800 1800 1550 1550 1800 1280 950 950 1300 850 630 630 790 520 390 390

2.5 1800 1800 1800 1800 1800 1540 1140 1140 1560 1020 760 760 950 620 460 460

3 1800 1800 1800 1800 1800 1800 1390 1390 1800 1250 930 930 1160 760 570 570

4 1800 1800 1800 1800 1800 1800 1730 1730 1800 1550 1150 1150 1430 940 700 700

1 1800 1650 1220 1220 1540 1010 750 750 1020 670 500 500 620 410 N/A N/A

2 1800 1800 1550 1550 1800 1280 950 950 1300 850 630 630 790 520 390 390

2.5 1800 1800 1800 1800 1800 1540 1140 1140 1560 1020 760 760 950 620 460 460

3 1800 1800 1800 1800 1800 1800 1390 1390 1800 1250 930 930 1160 760 570 570

4 1800 1800 1800 1800 1800 1800 1730 1730 1800 1550 1150 1150 1430 940 700 700

1 1800 1650 1220 1220 1540 1010 750 750 1020 670 500 500 620 410 N/A N/A

2 1800 1800 1550 1550 1800 1280 950 950 1300 850 630 630 790 520 390 390

2.5 1800 1800 1800 1740 1800 1540 1140 1140 1560 1020 760 760 950 620 460 460

3 1800 1800 1800 1800 1800 1800 1390 1390 1800 1250 930 930 1160 760 570 570

4 1800 1800 1800 1800 1800 1800 1730 1730 1800 1550 1150 1150 1430 940 700 700

1 1270 830 610 400 770 500 370 250 510 340 250 N/A 310 210 N/A N/A

2 1630 1050 780 510 980 640 470 310 650 430 320 210 400 260 N/A N/A

2.5 1800 1270 940 610 1180 770 570 370 780 510 380 250 470 310 230 N/A

3 1800 1570 1150 750 1460 950 700 460 960 630 470 310 580 380 280 N/A

4 1800 1800 1430 930 1800 1170 860 570 1190 780 570 380 720 470 350 230

1 1520 980 730 730 920 600 440 440 610 400 300 300 370 240 N/A N/A

2 1800 1250 920 920 1170 760 560 560 770 500 370 370 470 310 230 230

2.5 1800 1520 1110 1110 1410 910 680 680 930 610 450 450 560 370 270 270

3 1800 1800 1370 1370 1750 1130 830 830 1140 740 550 550 690 450 340 340

4 1800 1800 1710 1710 1800 1400 1030 1030 1420 920 680 680 850 560 410 410

1 1520 980 730 730 920 600 440 440 610 400 300 300 370 240 N/A N/A

2 1800 1250 920 920 1170 760 560 560 770 500 370 370 470 310 230 230

2.5 1800 1520 1110 1110 1410 910 680 680 930 610 450 450 560 370 270 270

3 1800 1800 1370 1370 1750 1130 830 830 1140 740 550 550 690 450 340 340

4 1800 1800 1710 1710 1800 1400 1030 1030 1420 920 680 680 850 560 410 410

1 1520 980 730 730 920 600 440 440 610 400 300 300 370 240 N/A N/A

2 1800 1250 920 920 1170 760 560 560 770 500 370 370 470 310 230 230

2.5 1800 1520 1110 1110 1410 910 680 680 930 610 450 450 560 370 270 270

3 1800 1800 1370 1370 1750 1130 830 830 1140 740 550 550 690 450 340 340

4 1800 1800 1710 1670 1800 1400 1030 1030 1420 920 680 680 850 560 410 410

Trina Mount II Span Tables

Po

rtra

it

0 t

o 1

4

de

gre

es

(Fla

t

to 3

:12

)

>1

4 t

o 2

7

(>3

:12

to

6:1

2)

>2

7 t

o 3

7

(>6

:12

to

9:1

2)

>3

7 t

o 4

5

(>9

:12

to

12

:12

)

Wind Region D

Table 2-- Max Spacing for the Big Foot with 2 Screws into Custom Orb Roofing or Trimdek with Wooden Battens

Module

OrientationRoof Pitch

Wind Region B Wind Region CWind Region ALa

nd

sca

pe

0 t

o 1

4

de

gre

es

(Fla

t

to 3

:12

)

>1

4 t

o 2

7

(>3

:12

to

6:1

2)

>2

7 t

o 3

7

(>6

:12

to

9:1

2)

>3

7 t

o 4

5

(>9

:12

to

12

:12

)

v1.0

Roof Zone Interior Edge 1 Edge 2 Corner Interior Edge 1 Edge 2 Corner Interior Edge 1 Edge 2 Corner Interior Edge 1 Edge 2 Corner

Terrain Category

1 1800 1370 1010 N/A 1280 840 620 N/A 510 330 N/A N/A 310 200 N/A N/A

2 1800 1740 1280 740 1620 1060 790 520 640 420 310 N/A 390 260 N/A N/A

2.5 1800 1800 1550 1010 1800 1270 940 620 770 510 380 N/A 470 310 230 N/A

3 1800 1800 1800 1240 1800 1560 1160 760 950 620 460 300 580 380 280 N/A

4 1800 1800 1800 1540 1800 1800 1430 940 1180 770 570 370 710 470 350 230

1 1800 1630 1200 1200 1510 990 740 740 600 400 290 290 370 240 N/A N/A

2 1800 1800 1530 1530 1800 1260 930 930 760 500 370 370 460 300 230 230

2.5 1800 1800 1800 1800 1800 1510 1120 1120 920 600 450 450 560 370 270 270

3 1800 1800 1800 1800 1800 1800 1370 1370 1130 740 550 550 680 450 330 330

4 1800 1800 1800 1800 1800 1800 1700 1700 1410 910 670 670 850 550 410 410

1 1800 1630 1200 1200 1510 990 740 740 600 400 290 290 370 240 N/A N/A

2 1800 1800 1530 1530 1800 1260 930 930 760 500 370 370 460 300 230 230

2.5 1800 1800 1800 1800 1800 1510 1120 1120 920 600 450 450 560 370 270 270

3 1800 1800 1800 1800 1800 1800 1370 1370 1130 740 550 550 680 450 330 330

4 1800 1800 1800 1800 1800 1800 1700 1700 1410 910 670 670 850 550 410 410

1 1800 1630 1200 1200 1510 990 740 740 600 400 290 290 370 240 N/A N/A

2 1800 1800 1530 1530 1800 1260 930 930 760 500 370 370 460 300 230 230

2.5 1800 1800 1800 1740 1800 1510 1120 1120 920 600 450 450 560 370 270 270

3 1800 1800 1800 1800 1800 1800 1370 1370 1130 740 550 550 680 450 330 330

4 1800 1800 1800 1800 1800 1800 1700 1700 1410 910 670 670 850 550 410 410

1 1250 810 600 400 760 500 370 240 300 200 N/A N/A N/A N/A N/A N/A

2 1600 1040 760 500 960 630 470 310 380 250 N/A N/A 230 N/A N/A N/A

2.5 1800 1250 920 600 1160 760 560 370 460 300 220 N/A 280 N/A N/A N/A

3 1800 1550 1130 740 1440 930 690 450 570 370 270 N/A 340 220 N/A N/A

4 1800 1800 1410 910 1790 1150 850 560 700 460 340 220 420 280 200 N/A

1 1500 970 710 710 900 590 440 440 360 230 N/A N/A 220 N/A N/A N/A

2 1800 1230 910 910 1150 750 550 550 450 300 220 220 270 N/A N/A N/A

2.5 1800 1490 1100 1100 1390 900 670 670 550 360 260 260 330 220 N/A N/A

3 1800 1800 1350 1350 1720 1110 820 820 670 440 320 320 410 270 200 200

4 1800 1800 1690 1690 1800 1380 1010 1010 840 540 400 400 500 330 240 240

1 1500 970 710 710 900 590 440 440 360 230 N/A N/A 220 N/A N/A N/A

2 1800 1230 910 910 1150 750 550 550 450 300 220 220 270 N/A N/A N/A

2.5 1800 1490 1100 1100 1390 900 670 670 550 360 260 260 330 220 N/A N/A

3 1800 1800 1350 1350 1720 1110 820 820 670 440 320 320 410 270 200 200

4 1800 1800 1690 1690 1800 1380 1010 1010 840 540 400 400 500 330 240 240

1 1500 970 710 710 900 590 440 440 360 230 N/A N/A 220 N/A N/A N/A

2 1800 1230 910 910 1150 750 550 550 450 300 220 220 270 N/A N/A N/A

2.5 1800 1490 1100 1100 1390 900 670 670 550 360 260 260 330 220 N/A N/A

3 1800 1800 1350 1350 1720 1110 820 820 670 440 320 320 410 270 200 200

4 1800 1800 1690 1670 1800 1380 1010 1010 840 540 400 400 500 330 240 240

Trina Mount II Span TablesTable 3-- Max Spacing for the Big Foot with 3 Screws into Custom Orb Roofing with Metal Battens

Module

OrientationRoof Pitch

Wind Region A Wind Region B Wind Region C Wind Region DLa

nd

sca

pe

0 t

o 1

4

de

gre

es

(Fla

t

to 3

:12

)

>1

4 t

o 2

7

(>3

:12

to

6:1

2)

>2

7 t

o 3

7

(>6

:12

to

9:1

2)

>3

7 t

o 4

5

(>9

:12

to

12

:12

)

Po

rtra

it

0 t

o 1

4

de

gre

es

(Fla

t

to 3

:12

)

>1

4 t

o 2

7

(>3

:12

to

6:1

2)

>2

7 t

o 3

7

(>6

:12

to

9:1

2)

>3

7 t

o 4

5

(>9

:12

to

12

:12

)

v1.0

Roof Zone Interior Edge 1 Edge 2 Corner Interior Edge 1 Edge 2 Corner Interior Edge 1 Edge 2 Corner Interior Edge 1 Edge 2 Corner

Terrain Category

1 1400 910 670 N/A 850 560 410 N/A 340 220 N/A N/A 200 N/A N/A N/A

2 1790 1160 850 560 1080 700 520 340 430 280 210 N/A 260 N/A N/A N/A

2.5 1800 1400 1030 670 1300 850 630 410 510 340 250 N/A 310 200 N/A N/A

3 1800 1730 1270 830 1610 1040 770 500 630 410 310 200 380 250 N/A N/A

4 1800 1800 1580 1020 1800 1290 950 620 790 510 380 250 470 310 230 N/A

1 1670 1080 800 800 1010 660 490 490 400 260 N/A N/A 240 N/A N/A N/A

2 1800 1380 1020 1020 1280 840 620 620 510 330 250 250 310 200 N/A N/A

2.5 1800 1670 1230 1230 1550 1010 740 740 610 400 300 300 370 240 N/A N/A

3 1800 1800 1510 1510 1800 1240 910 910 750 490 360 360 450 300 220 220

4 1800 1800 1800 1800 1800 1540 1130 1130 940 610 450 450 560 370 270 270

1 1670 1080 800 800 1010 660 490 490 400 260 N/A N/A 240 N/A N/A N/A

2 1800 1380 1020 1020 1280 840 620 620 510 330 250 250 310 200 N/A N/A

2.5 1800 1670 1230 1230 1550 1010 740 740 610 400 300 300 370 240 N/A N/A

3 1800 1800 1510 1510 1800 1240 910 910 750 490 360 360 450 300 220 220

4 1800 1800 1800 1800 1800 1540 1130 1130 940 610 450 450 560 370 270 270

1 1670 1080 800 800 1010 660 490 490 400 260 N/A N/A 240 N/A N/A N/A

2 1800 1380 1020 1020 1280 840 620 620 510 330 250 250 310 200 N/A N/A

2.5 1800 1670 1230 1230 1550 1010 740 740 610 400 300 300 370 240 N/A N/A

3 1800 1800 1510 1510 1800 1240 910 910 750 490 360 360 450 300 220 220

4 1800 1800 1800 1800 1800 1540 1130 1130 940 610 450 450 560 370 270 270

1 830 540 400 260 500 330 240 N/A 200 N/A N/A N/A N/A N/A N/A N/A

2 1070 690 510 330 640 420 310 200 250 N/A N/A N/A N/A N/A N/A N/A

2.5 1300 830 610 400 770 500 370 240 300 200 N/A N/A N/A N/A N/A N/A

3 1620 1030 750 490 960 620 460 300 380 240 N/A N/A 230 N/A N/A N/A

4 1800 1290 940 610 1190 770 570 370 470 300 220 N/A 280 N/A N/A N/A

1 1000 640 470 470 600 390 290 290 240 N/A N/A N/A N/A N/A N/A N/A

2 1280 820 600 600 760 500 370 370 300 200 N/A N/A N/A N/A N/A N/A

2.5 1560 990 730 730 920 600 440 440 360 240 N/A N/A 220 N/A N/A N/A

3 1800 1230 900 900 1140 740 540 540 450 290 210 210 270 N/A N/A N/A

4 1800 1550 1120 1120 1430 920 670 670 560 360 270 270 330 220 N/A N/A

1 1000 640 470 470 600 390 290 290 240 N/A N/A N/A N/A N/A N/A N/A

2 1280 820 600 600 760 500 370 370 300 200 N/A N/A N/A N/A N/A N/A

2.5 1560 990 730 730 920 600 440 440 360 240 N/A N/A 220 N/A N/A N/A

3 1800 1230 900 900 1140 740 540 540 450 290 210 210 270 N/A N/A N/A

4 1800 1550 1120 1120 1430 920 670 670 560 360 270 270 330 220 N/A N/A

1 1000 640 470 470 600 390 290 290 240 N/A N/A N/A N/A N/A N/A N/A

2 1280 820 600 600 760 500 370 370 300 200 N/A N/A N/A N/A N/A N/A

2.5 1560 990 730 730 920 600 440 440 360 240 N/A N/A 220 N/A N/A N/A

3 1800 1230 900 900 1140 740 540 540 450 290 210 210 270 N/A N/A N/A

4 1800 1550 1120 1120 1430 920 670 670 560 360 270 270 330 220 N/A N/A

Trina Mount II Span TablesTable 4-- Max Spacing for the Big Foot with 2 Screws into Custom Orb Roofing or Trimdek with Metal Battens

Module

OrientationRoof Pitch

Wind Region A Wind Region B Wind Region C Wind Region DLa

nd

sca

pe

0 t

o 1

4

de

gre

es

(Fla

t

to 3

:12

)

>1

4 t

o 2

7

(>3

:12

to

6:1

2)

>2

7 t

o 3

7

(>6

:12

to

9:1

2)

>3

7 t

o 4

5

(>9

:12

to

12

:12

)

Po

rtra

it

0 t

o 1

4

de

gre

es

(Fla

t

to 3

:12

)

>1

4 t

o 2

7

(>3

:12

to

6:1

2)

>2

7 t

o 3

7

(>6

:12

to

9:1

2)

>3

7 t

o 4

5

(>9

:12

to

12

:12

)

v1.0