AppliChem © 2010 1/42 There is another top address in Darmstadt! ExitusPlus™ Technology ...

43
AppliChem © 2010 1/42 There is another top address in Darmstadt! ExitusPlus™ Technology Contamination by Nucleic Acids Decontamination of Nucleic Acids RNase-ExitusPlus maxXbond

Transcript of AppliChem © 2010 1/42 There is another top address in Darmstadt! ExitusPlus™ Technology ...

Page 1: AppliChem © 2010 1/42 There is another top address in Darmstadt! ExitusPlus™ Technology  Contamination by Nucleic Acids  Decontamination of Nucleic Acids.

AppliChem © 2010 1/42

There is another top address in Darmstadt!

ExitusPlus™ Technology

Contamination by Nucleic Acids

Decontamination of Nucleic Acids

RNase-ExitusPlus

maxXbond

Page 2: AppliChem © 2010 1/42 There is another top address in Darmstadt! ExitusPlus™ Technology  Contamination by Nucleic Acids  Decontamination of Nucleic Acids.

AppliChem © 2010 2/42

There is another top address in Darmstadt!

Regeneration of Nucleic Acid Purification Matrices

Page 3: AppliChem © 2010 1/42 There is another top address in Darmstadt! ExitusPlus™ Technology  Contamination by Nucleic Acids  Decontamination of Nucleic Acids.

AppliChem © 2010 3/42

There is another top address in Darmstadt!

• based on ExitusPlus technology

• for the multiple use of DNA-binding columns

maxXbond

Page 4: AppliChem © 2010 1/42 There is another top address in Darmstadt! ExitusPlus™ Technology  Contamination by Nucleic Acids  Decontamination of Nucleic Acids.

AppliChem © 2010 4/42

There is another top address in Darmstadt!

RG1

RG2

centrifugation

degrades nucleic acids

incubation(30 minutes)

removes residues

maxXbond

Page 5: AppliChem © 2010 1/42 There is another top address in Darmstadt! ExitusPlus™ Technology  Contamination by Nucleic Acids  Decontamination of Nucleic Acids.

AppliChem © 2010 5/42

There is another top address in Darmstadt!

• Quality testing I: DNA purity after regeneration

maxXbond

Page 6: AppliChem © 2010 1/42 There is another top address in Darmstadt! ExitusPlus™ Technology  Contamination by Nucleic Acids  Decontamination of Nucleic Acids.

AppliChem © 2010 6/42

There is another top address in Darmstadt!

• Quality testing II: Binding capacity after regeneration

maxXbond

Page 7: AppliChem © 2010 1/42 There is another top address in Darmstadt! ExitusPlus™ Technology  Contamination by Nucleic Acids  Decontamination of Nucleic Acids.

AppliChem © 2010 7/42

There is another top address in Darmstadt!

• Quality testing III: Sequencing after regenereation

maxXbond

Page 8: AppliChem © 2010 1/42 There is another top address in Darmstadt! ExitusPlus™ Technology  Contamination by Nucleic Acids  Decontamination of Nucleic Acids.

AppliChem © 2010 8/42

There is another top address in Darmstadt!

• Quality testing IV: Stability testing after regenereationno residual RG1 on the columns

linearized plasmid DNA

maxXbond

Page 9: AppliChem © 2010 1/42 There is another top address in Darmstadt! ExitusPlus™ Technology  Contamination by Nucleic Acids  Decontamination of Nucleic Acids.

AppliChem © 2010 9/42

There is another top address in Darmstadt!

For the small ones (Mini columns) pure Silica matrices

... and the larger ones (Midi, Maxi, Mega, Giga)

AX = Anion eXchanger

• The small difference with the big consequences:

maxXbond

Page 10: AppliChem © 2010 1/42 There is another top address in Darmstadt! ExitusPlus™ Technology  Contamination by Nucleic Acids  Decontamination of Nucleic Acids.

AppliChem © 2010 10/42

There is another top address in Darmstadt!

• Indication of DNA contaminations of new columns

van der Zee & Crielaad (2002) Journal of Clinical Microbiology 40, 1126

Evans et al. (2003) Journal of Clinical Microbiology, 41, 3452-3453

Remco et al. (2004) EMS Immunology and Medical Microbiology 42, 249-253

Detection of contamination with Legionella -DNA

DNA contamination leads to false-positive findings

maxXbond

Page 11: AppliChem © 2010 1/42 There is another top address in Darmstadt! ExitusPlus™ Technology  Contamination by Nucleic Acids  Decontamination of Nucleic Acids.

AppliChem © 2010 11/42

There is another top address in Darmstadt!

• Refill Buffer Set for maxXbond regenerated columns maxXmore

AppliChem's 5* Star buffer set (S1 - S5)optimized for maxXbond-regenerated columns

- all buffers ready-to-use- no edition of ethanol required- storage at ambient temperature

Page 12: AppliChem © 2010 1/42 There is another top address in Darmstadt! ExitusPlus™ Technology  Contamination by Nucleic Acids  Decontamination of Nucleic Acids.

AppliChem © 2010 12/42

There is another top address in Darmstadt!

• Refill Buffer Set for maxXbond AX regenerated columns

maxXmore AX

AppliChem's 6* Star buffer set (SM1 - SM6)optimized for maxXbond AX-regenerated columns

- all buffers ready-to-use- no addition of ethanol required- storage at ambient temperature

Page 13: AppliChem © 2010 1/42 There is another top address in Darmstadt! ExitusPlus™ Technology  Contamination by Nucleic Acids  Decontamination of Nucleic Acids.

AppliChem © 2010 13/42

There is another top address in Darmstadt!

Conta-Conta-minationmination

Page 14: AppliChem © 2010 1/42 There is another top address in Darmstadt! ExitusPlus™ Technology  Contamination by Nucleic Acids  Decontamination of Nucleic Acids.

AppliChem © 2010 14/42

There is another top address in Darmstadt!

o In all biological laboratories

• Nucleic acids are everywhere

Contamination by Nucleic Acids

o In the environment

Page 15: AppliChem © 2010 1/42 There is another top address in Darmstadt! ExitusPlus™ Technology  Contamination by Nucleic Acids  Decontamination of Nucleic Acids.

AppliChem © 2010 15/42

There is another top address in Darmstadt!

o Cloning

o PCR

o Transformation

o Genomic DNA Isolation

o Plasmid DNA Isolation

Contamination by Nucleic Acids

Page 16: AppliChem © 2010 1/42 There is another top address in Darmstadt! ExitusPlus™ Technology  Contamination by Nucleic Acids  Decontamination of Nucleic Acids.

AppliChem © 2010 16/42

There is another top address in Darmstadt!

• Aerosols after autoclaving

Contamination by Nucleic Acids

• Aerosols during pipetting

• Aerosols during centrifugation

• Personell, environment, ventilation

• Reagents, kits, water, plastic ware

• Spills during handling

Page 17: AppliChem © 2010 1/42 There is another top address in Darmstadt! ExitusPlus™ Technology  Contamination by Nucleic Acids  Decontamination of Nucleic Acids.

AppliChem © 2010 17/42

There is another top address in Darmstadt!

• are detectable

Contamination by Nucleic Acids

• lead to false positive results

• may be harmful

Page 18: AppliChem © 2010 1/42 There is another top address in Darmstadt! ExitusPlus™ Technology  Contamination by Nucleic Acids  Decontamination of Nucleic Acids.

AppliChem © 2010 18/42

There is another top address in Darmstadt!

DecontaDecontaminationmination

Page 19: AppliChem © 2010 1/42 There is another top address in Darmstadt! ExitusPlus™ Technology  Contamination by Nucleic Acids  Decontamination of Nucleic Acids.

AppliChem © 2010 19/42

There is another top address in Darmstadt!

• UV light

Decontamination of Nucleic Acids

• Chemical reagents

• Thermal destruction

Page 20: AppliChem © 2010 1/42 There is another top address in Darmstadt! ExitusPlus™ Technology  Contamination by Nucleic Acids  Decontamination of Nucleic Acids.

AppliChem © 2010 20/42

There is another top address in Darmstadt!

Decontamination of Nucleic Acids

• no method is 100 % safe

• all methods destroy equipment

• some simply doesn‘t work

Page 21: AppliChem © 2010 1/42 There is another top address in Darmstadt! ExitusPlus™ Technology  Contamination by Nucleic Acids  Decontamination of Nucleic Acids.

AppliChem © 2010 21/42

There is another top address in Darmstadt!

o strong mineralic acids and bases

except for bleach not very effective

Decontamination of Nucleic Acids

• chemical reagents

o peroxides

o azides

o hypochlorite ("bleach")

o organic solvents (toxic fumes)

Page 22: AppliChem © 2010 1/42 There is another top address in Darmstadt! ExitusPlus™ Technology  Contamination by Nucleic Acids  Decontamination of Nucleic Acids.

AppliChem © 2010 22/42

There is another top address in Darmstadt!

Description Hazard Symbol UN Class/PG

DNA-ExitusPlus / IF - -

DNA ZAP C

RNase ZAP Xi UN3267 8/III

DNA away Xi

RNase away Xi UN1824 8/II

DNA-erase Xi

RNase-erase Xi

DNA-OFF Xn

RNase-OFF Xn

DNA-Remover C, N

LTK007 (Xn)

DNA-Decontamination Reagent Xi

Roti-Nukleinsäurefrei Xi

bleach C UN1791 8/II

Decontamination of Nucleic Acids

• chemical reagents

Page 23: AppliChem © 2010 1/42 There is another top address in Darmstadt! ExitusPlus™ Technology  Contamination by Nucleic Acids  Decontamination of Nucleic Acids.

AppliChem © 2010 23/42

There is another top address in Darmstadt!

• aqueous solution* or powder

• all components biodegradable

• synergistic action of biomolecules and a mild acid

• low concentration of all ingredients

• noncorrosive, nontoxic

• very effective, especially at elevated temperatures

Decontamination of Nucleic Acids

* contains < 10 % of alcohol

Exi†usPlus™ technology

Page 24: AppliChem © 2010 1/42 There is another top address in Darmstadt! ExitusPlus™ Technology  Contamination by Nucleic Acids  Decontamination of Nucleic Acids.

AppliChem © 2010 24/42

There is another top address in Darmstadt!

• with / without color indicatorDNA-ExitusPlus™ only

• active as long as not dried up

• simply remove by wiping off

Decontamination of Nucleic Acids

Page 25: AppliChem © 2010 1/42 There is another top address in Darmstadt! ExitusPlus™ Technology  Contamination by Nucleic Acids  Decontamination of Nucleic Acids.

AppliChem © 2010 25/42

There is another top address in Darmstadt!

M 1 kb DNA ladder

K control (sterile H2O)

X1 DNA-OFF™

X2 DNA-ZAP™

X3 0.25 M NaOH, 0.5 % SDS

X4 DNA-Away™

D DNA-Exitus™ (discont.)

D+ DNA-ExitusPlus™

D+ DNA-ExitusPlus™

(10 min incubation)

M 1 kb DNA ladder

M K X1 X2 X3 X4 D D+ D+ M

- 500 bp

- 1000 bp

- 50 bp

Incubation 3 min 10 min

Decontamination of Nucleic Acids• Quality control

Page 26: AppliChem © 2010 1/42 There is another top address in Darmstadt! ExitusPlus™ Technology  Contamination by Nucleic Acids  Decontamination of Nucleic Acids.

AppliChem © 2010 26/42

There is another top address in Darmstadt!

X2 H2O X3 D+ X4

silver with gold cover

silver

stainless steel

aluminium

copper

zinc

X2, X3, X4: competitors, D+: DNA-ExitusPlus

Decontamination of Nucleic Acids• Quality control

Page 27: AppliChem © 2010 1/42 There is another top address in Darmstadt! ExitusPlus™ Technology  Contamination by Nucleic Acids  Decontamination of Nucleic Acids.

AppliChem © 2010 27/42

There is another top address in Darmstadt!

• Aerosols during pipetting

• Aerosols during centrifugation

• Aerosols after autoclaving

• Spills during handling

• Reagents, kits, water, plastic ware

• Personell, environment, ventilation

Contamination by Nucleic Acids

Page 28: AppliChem © 2010 1/42 There is another top address in Darmstadt! ExitusPlus™ Technology  Contamination by Nucleic Acids  Decontamination of Nucleic Acids.

AppliChem © 2010 28/42

There is another top address in Darmstadt!

Case Study I

Source: http://www.uni-mainz.de/FB/Biologie/Anthropologie/MolA/English/Laboratory/Laboratory.html

Ancient DNA Lab

Contamination by Nucleic Acids

Page 29: AppliChem © 2010 1/42 There is another top address in Darmstadt! ExitusPlus™ Technology  Contamination by Nucleic Acids  Decontamination of Nucleic Acids.

AppliChem © 2010 29/42

There is another top address in Darmstadt!

Sawing Room

DNA ExtractionUV Room

Sample Preparation

PCR Room

Lock II

Lock I

Ancient DNA Lab

Case Study I Contamination by Nucleic Acids

Page 30: AppliChem © 2010 1/42 There is another top address in Darmstadt! ExitusPlus™ Technology  Contamination by Nucleic Acids  Decontamination of Nucleic Acids.

AppliChem © 2010 30/42

There is another top address in Darmstadt!

• Measures to prevent DNA contamination:

o Locks (sealed rooms)

Case Study I Contamination by Nucleic Acids

Ancient DNA Lab

o Separation of pre-PCR and PCR areas: separate rooms

o regular decontamination with DNA-ExitusPlus IF of surfaces and equipment.decontamination of rooms with sodium hypochlorite[e.g. Chlorox]

Page 31: AppliChem © 2010 1/42 There is another top address in Darmstadt! ExitusPlus™ Technology  Contamination by Nucleic Acids  Decontamination of Nucleic Acids.

AppliChem © 2010 31/42

There is another top address in Darmstadt!

State Police Departments

customer statement published as interview (LKA State of Thuringia) in labor&more 0107

• DNA decontamination of 1. surgical instruments & 2. PCR workstations

Case Study II Contamination by Nucleic Acids

Page 32: AppliChem © 2010 1/42 There is another top address in Darmstadt! ExitusPlus™ Technology  Contamination by Nucleic Acids  Decontamination of Nucleic Acids.

AppliChem © 2010 32/42

There is another top address in Darmstadt!

Tissue Sectioning

http:

//p l

ato.

wilm

i ngt

on.e

du/f

acu l

ty/d

troi

ke/M

o use

_ ana

tom

y_01

2.J P

G

Case Study III Contamination by Nucleic Acids

Page 33: AppliChem © 2010 1/42 There is another top address in Darmstadt! ExitusPlus™ Technology  Contamination by Nucleic Acids  Decontamination of Nucleic Acids.

AppliChem © 2010 33/42

There is another top address in Darmstadt!

Seed controlCase Study IV

Contamination by Nucleic Acids

DSV laboratories analyze rape DNA from seeds in high-throughput screening, up to 36 x 96 well plates per day.

Requirements: DNA isolation from single rape seeds (1 - 3 mm diameter); therefore very small amounts of starting material of PCR templates for subsequent PCR. Highest priority: prevention of cross-contamination by DNA.

Page 34: AppliChem © 2010 1/42 There is another top address in Darmstadt! ExitusPlus™ Technology  Contamination by Nucleic Acids  Decontamination of Nucleic Acids.

AppliChem © 2010 34/42

There is another top address in Darmstadt!

Seed controlCase Study IV

Contamination by Nucleic Acids

Multiplex-PCR for identification of species with 3 specific PCR products (arrows).

Appearance of increasing numbers of unspecific PCR products (brackets).

Page 35: AppliChem © 2010 1/42 There is another top address in Darmstadt! ExitusPlus™ Technology  Contamination by Nucleic Acids  Decontamination of Nucleic Acids.

AppliChem © 2010 35/42

There is another top address in Darmstadt!

Seed controlCase Study IV

Contamination by Nucleic Acids

Problem of unspecific PCR products caused false-negative (red arrows) or false-positive results and background (brackets).

Page 36: AppliChem © 2010 1/42 There is another top address in Darmstadt! ExitusPlus™ Technology  Contamination by Nucleic Acids  Decontamination of Nucleic Acids.

AppliChem © 2010 36/42

There is another top address in Darmstadt!

Seed controlCase Study IV

Contamination by Nucleic Acids

Measures to prevent contamination:

1. Removal of the autoclave from the neighbouring laboratory

2. Washing out the autoclave, refrigerator and table-top centrifuges with DNA-ExitusPlus IF

3. Regular decontamination with DNA-ExitusPlus IF ofpre-PCR area, PCR workstation, as well as pipetts

Page 37: AppliChem © 2010 1/42 There is another top address in Darmstadt! ExitusPlus™ Technology  Contamination by Nucleic Acids  Decontamination of Nucleic Acids.

AppliChem © 2010 37/42

There is another top address in Darmstadt!

Contamination by Nucleic Acids

• Autoclave-ExitusPlus™

o autoclaves are a main source of contamination

o vapours contain nucleic acids

o incomplete degradation of nucleic acids during autoclaving

o the complete AmpR gene detectable after autoclaving

Page 38: AppliChem © 2010 1/42 There is another top address in Darmstadt! ExitusPlus™ Technology  Contamination by Nucleic Acids  Decontamination of Nucleic Acids.

AppliChem © 2010 38/42

There is another top address in Darmstadt!

Contamination by Nucleic Acids

• Autoclave-ExitusPlus™

Fig. 1: Equal volumes of either water (H2O) or Autoclave-ExitusPlus (D+), respectively, were added to 50 ml cultures of recombinant E. coli and autoclaved at 120°C and 1.2 bar for 20 min.

- 500 bp

- 1000 bp

- ~20 bp

H2O D+ M

930 bp, AmpR-Gen -

M pos. M contr. H2O D+

Fig. 2: PCR analysis of autoclaved E. coli cultures from fig 1.

Page 39: AppliChem © 2010 1/42 There is another top address in Darmstadt! ExitusPlus™ Technology  Contamination by Nucleic Acids  Decontamination of Nucleic Acids.

AppliChem © 2010 39/42

There is another top address in Darmstadt!

typical contamination with RNase

Contamination by Ribonuclease (RNase)

Page 40: AppliChem © 2010 1/42 There is another top address in Darmstadt! ExitusPlus™ Technology  Contamination by Nucleic Acids  Decontamination of Nucleic Acids.

AppliChem © 2010 40/42

There is another top address in Darmstadt!

Lane:1: RNase-ExitusPlus

2: empty slot3: H2O

4: 10 g RNase A5: empty slot

C: untreated total RNA

1, 3, 4 = plus 10 µg RNase A

1, 3, 4 = treatment as indicated

1, 3, 4 = plus 5 µg RNA

4 = plus 10 µg RNase A

Decontamination of Ribonuclease (RNase)

Page 41: AppliChem © 2010 1/42 There is another top address in Darmstadt! ExitusPlus™ Technology  Contamination by Nucleic Acids  Decontamination of Nucleic Acids.

AppliChem © 2010 41/42

There is another top address in Darmstadt!

Decontamination of Ribonuclease (RNase)

Page 42: AppliChem © 2010 1/42 There is another top address in Darmstadt! ExitusPlus™ Technology  Contamination by Nucleic Acids  Decontamination of Nucleic Acids.

AppliChem © 2010 42/42

There is another top address in Darmstadt!

DNA-ExitusPlus™

DNA-ExitusPlus™ IF

surfacedecontamination

Autoclave-ExitusPlus™ additive duringautoclaving

maxXbond™

maxXbond™ AX

columnregeneration

Exi†usPlus™ technology

Decontamination of Nucleic Acids

Page 43: AppliChem © 2010 1/42 There is another top address in Darmstadt! ExitusPlus™ Technology  Contamination by Nucleic Acids  Decontamination of Nucleic Acids.

AppliChem © 2010 43/42

There is another top address in Darmstadt!

• Best price!

• Best activity!

• Most pack sizes (100 ml - 1 L spray; refills)

• Best compatibility! Not harmful!

• Many potential customers

• Consumption 1 L / 10 m²

Decontamination: more sales arguments