An incident is just the tip of the iceberg, a sign of a ...cidm.in/pdf/Day1/3.pdf · OISD-STD -244:...

11
16122019 1 www.pahwametaltech.co.in © Pahwa MetalTech Private Limited Safety of People and Assets Working in Environments Containing Inflammable Liquids and Gases 1 Chemical and Industrial Disaster Management 5-6 December 2019 | Gangtok, Sikkim Presented By: Lalit Kumar Pahwa Managing Director Pahwa MetalTech Private Limited [email protected] www.pahwametaltech.co.in © Pahwa MetalTech Private Limited 2 An incident is just the tip of the iceberg, a sign of a much larger problem below the surface

Transcript of An incident is just the tip of the iceberg, a sign of a ...cidm.in/pdf/Day1/3.pdf · OISD-STD -244:...

Page 1: An incident is just the tip of the iceberg, a sign of a ...cidm.in/pdf/Day1/3.pdf · OISD-STD -244: Storage and Handling of Petroleum Products at Depots & Terminals. OISD – 144

16‐12‐2019

1

www.pahwametaltech.co.in© Pahwa MetalTech Private Limited

Safety of People and Assets Working in Environments Containing Inflammable Liquids and Gases

1

Chemical and Industrial Disaster Management5-6 December 2019 | Gangtok, Sikkim

Presented By: Lalit Kumar PahwaManaging Director Pahwa MetalTech Private [email protected]

www.pahwametaltech.co.in© Pahwa MetalTech Private Limited 2

An incident is just the tip of the iceberg, a sign of a much larger problem below the surface

Page 2: An incident is just the tip of the iceberg, a sign of a ...cidm.in/pdf/Day1/3.pdf · OISD-STD -244: Storage and Handling of Petroleum Products at Depots & Terminals. OISD – 144

16‐12‐2019

2

www.pahwametaltech.co.in© Pahwa MetalTech Private Limited

Blast in Annpara D Power Station

3

A massive explosion at the generator-turbine of the500 Megawatt unit (Unit 7) of Annpara D power stationon November 13, 2019.

Unattended hydrogen leak from the generator wasidentified prima facie as a major trigger.

It was not attended by shutting the plant andthere was anticipation that it can be fixedwithout shutting the unit.

Some workers who were unaware of the leakwere trying to fix some dirt blocks and loosenuts and bearings in the generator.

Non-(spark-proof) spanners andequipment could have triggered sparks.

https://www.downtoearth.org.in/news/energy/blast-in-anpara-d-power-station-67746 , 14 November 2019Source:

www.pahwametaltech.co.in© Pahwa MetalTech Private Limited

OSHA inspection # 2272953

Two employees were assigned the job of tending a 100 gallon (water jacket)reactor kettle of methyl methacrylate in the mixing room.

Employee #1 used a metal wrench (visegrips) to pry open the cover of akettle. The wrench handle struck the angle iron support for the agitatormotor, producing a spark.

Employee #2 noticed the spark, which was immediately followed by amassive “fire ball”. Both employees were engulfed in the fireball.

The investigation states that non-sparking tools were not provided forthe employees. All three employees received first, and second degreeburns on their face, arms and abdomen.

Employee #2 also received some third-degree burns.

4

Page 3: An incident is just the tip of the iceberg, a sign of a ...cidm.in/pdf/Day1/3.pdf · OISD-STD -244: Storage and Handling of Petroleum Products at Depots & Terminals. OISD – 144

16‐12‐2019

3

www.pahwametaltech.co.in© Pahwa MetalTech Private Limited

OSHA inspection #102826625

Employee #1 worked for a company that cleans paints andreplaces valves of Propane gas cylinders.

Before removing an old valve, Employee #1 would open the valveto let the residual gas leak out on the loading dock. Where therewere large quantity of cylinders.

Employee #1 had an accumulation of a gas and air mixture aroundhis work area. The vapors were ignited either by a spark fromthe metal screwdriver he was using to open a damaged valve.

There was a fire and explosion. The employee sustained 2nd and3rd degree burns on the lower half of his body and washospitalized.

5

www.pahwametaltech.co.in© Pahwa MetalTech Private Limited

OSHA inspection #124728437

Employee #1 and a coworker, both maintenancemechanics, were working in a 30 inch by 36 inchmanhole at a gas station.

Employee #1 was trying to change a fuel pump,while the coworker watched from outside themanhole.

Employee #1 was using an Allen wrench toloosen the bolts on the fuel pump lead when hecreated a spark that ignited the gas fumes in themanhole, causing an explosion.

Employee #1 suffered burns to his face, hands,arms and legs in the explosion and washospitalized.

6

Page 4: An incident is just the tip of the iceberg, a sign of a ...cidm.in/pdf/Day1/3.pdf · OISD-STD -244: Storage and Handling of Petroleum Products at Depots & Terminals. OISD – 144

16‐12‐2019

4

www.pahwametaltech.co.in© Pahwa MetalTech Private Limited

Major Fire at Tank Wagon Siding

7

A major fire broke out in one of the tank wagon decantation railwaysiding of Oil Company during the first fortnight of January 2015.

While unloading was in progress, contractor workmen noticed that MSwas leaking from the flange joint connecting tank wagon unloadingheader and unloading hose of one of the MS tank wagon. The spilledMS was being collected in a bucket.

Without closing the bottom valve and master valve of the MS tankwagon, contract worker tried to tighten the bolt of the flange joint with aspanner to arrest the leakage.

During the process of tightening, the spanner slipped & fell downresulting in generation of spark. The MS vapors immediately caughtfire due to the spark and subsequently the MS tank wagon wasengulfed by the fire.

https://www.oisd.gov.in/Image/GetCaseStudyAttachment?caseStudyID=17Source:

www.pahwametaltech.co.in© Pahwa MetalTech Private Limited

Fire incident at a CCR Unit

8

A major fire took place in CCR (Continuous Catalytic Reformer)unit at level transmitter (LT) of the 2nd stage suction Knock-OutDrum (KOD) of Net Gas Compressor.

Cause of Fire:Passing of valve(s) from KOD-03, which was at a pressure of15 Kg/cm2 (g) at the level troll, resulted in accumulation of H2into the level troll. In fact KOD-03 was isolated by closing asingle valve without any positive isolation.

Opening of the flange on the drain line resulted in release of H2and Naphtha from the level troll which caught fire either byauto-ignition or due to generation of spark whilehammering the line by not using (non-sparking tools) to de-choke the line.

https://www.oisd.gov.in/Image/GetCaseStudyAttachment?caseStudyID=9Source:

Page 5: An incident is just the tip of the iceberg, a sign of a ...cidm.in/pdf/Day1/3.pdf · OISD-STD -244: Storage and Handling of Petroleum Products at Depots & Terminals. OISD – 144

16‐12‐2019

5

www.pahwametaltech.co.in© Pahwa MetalTech Private Limited

In all the cases highlighted there was loss of assets and human lives or grievous injuries.

Post accident audit of all cases identified one common reason - Non-Sparking Hand Tools were not used.

9

www.pahwametaltech.co.in© Pahwa MetalTech Private Limited

Industry Standards

10

OSHA Standards

Explosives & Blasting Agents 1910.109

Surface transportation of explosives 1926.902

Loading of explosives or blasting agents 1926.905

Spray Painting 1910.153

Criteria for Design & Construction of Spray Booths 1926.66

Substance data sheet Benzene 1910.1028

NFPA (National Fire Protection Association)

NFPA 51B: Standard for Fire Prevention During Welding, Cutting,

and Other Hot Work Projects.

NFPA 59A: Standard for the Production, Storage and Handling of

Liquified Natural Gas (LNG) governs the site selection, design,

construction, and fire protection of LNG Plants.

NFPA 69: Standard on Explosion Prevention Systems offers

definitive guidance on explosion, protection and prevention

systems.

NFPA 306: Standard for the Control of Gas Hazards on Vessels.

NFPA 53:2004: Materials, Equipments, And Systems used in

Oxygen- Enriched Atmospheres

NFPA 430:2004: Storage of Liquid and Solid Oxidizers

NFPA 704: Standard Systems for the identifications of the Hazard

of Materials for Emergency Response

NFPA 2: Hydrogen Technologies Code

OISD (Oil Industry Safety Directorate) Standards

OISD-STD -192: Safety Practices during Construction specifies working confined space.

OISD-STD -244: Storage and Handling of Petroleum Products at Depots & Terminals.

OISD – 144 : Liquefied Petroleum Gas (LPG) Installations

OISD-GDN- 207: Specify use of non-sparking tools in Demolishing activity in hazardous atmosphere.

OISD STD – 118 LLayouts for Oil and Gas Installations. OISD-RP-158 : Recommended Practices on Storage and Handling

of Bulk Liquefied Petroleum Gas

Page 6: An incident is just the tip of the iceberg, a sign of a ...cidm.in/pdf/Day1/3.pdf · OISD-STD -244: Storage and Handling of Petroleum Products at Depots & Terminals. OISD – 144

16‐12‐2019

6

www.pahwametaltech.co.in© Pahwa MetalTech Private Limited

Video (Click)

11

www.pahwametaltech.co.in© Pahwa MetalTech Private Limited

Over 1500+Standard Non-SparkingTools

Standard Products

12

Page 7: An incident is just the tip of the iceberg, a sign of a ...cidm.in/pdf/Day1/3.pdf · OISD-STD -244: Storage and Handling of Petroleum Products at Depots & Terminals. OISD – 144

16‐12‐2019

7

www.pahwametaltech.co.in© Pahwa MetalTech Private Limited

QTi® Bottom & Star Valve Wrench

13

Copper Titanium QTi® Star Valve Wrench is a customized non-sparking toolwhich was designed ergonomically and developed to easily and safely operatevalves mounted on the underside of the belly of a railway wagon and valvesmounted at the kerbside at storage locations. This well engineered tool meets along felt need of the users for a safe, strong and ergonomic non-sparking tool.

www.pahwametaltech.co.in© Pahwa MetalTech Private Limited

QTi® Top Valve Wrench

14

Copper Titanium QTi® Top Valve Wrench is a special non-sparkingtool which was developed to operate the Master Valve BTPN railwaywagons.

Page 8: An incident is just the tip of the iceberg, a sign of a ...cidm.in/pdf/Day1/3.pdf · OISD-STD -244: Storage and Handling of Petroleum Products at Depots & Terminals. OISD – 144

16‐12‐2019

8

www.pahwametaltech.co.in© Pahwa MetalTech Private Limited

QTi® Open Wrenches for LPG Filling Handling

15

QTi® Non-Sparking Open Wrenches are specially designedfor Coupling and Decoupling of Loading and Vapour Lines tothe LPG Bulk Tank Truck.

QTi® Open Wrenches are ergonomically designed byoptimizing the tool weight and is provided with a knurledhandle for better grip.

www.pahwametaltech.co.in© Pahwa MetalTech Private Limited

OISD – Emergency/HAZMAT Preparedness Tool Kit

16

Crate Opener- 36 x 230 mm OAL (BW-7004) Claw Hammer- 450 gms (HM-3045) Common Knife- 80 x 185 mm OAL (PK-1104) Deck Scraper- 45 x 300 mm OAL (SX-2045) Spray Booth Scraper- 76 x 235 mm OAL (SX-3076) Flat Screwdriver- 7 x 250 mm OAL (SD-1007) Combination Pliers- 200 mm OAL (PL-1008) Groove Joint Pliers- 300 mm OAL (PL-6012) Philips Screwdriver- #2, 7 x 250 mm OAL (SD-2007) Cutting Shears- 60 x 150 mm OAL (CU-1006) Adjustable Wrench- 24 x 200 mm OAL (AW-1008) Adjustable Wrench- 36 x 300 mm OAL (AW-1012) Pipe Wrench- 56 x 350 mm OAL (PW-1014) Bung Wrench- 300 mm OAL (BW-9004) Long Nose Pliers- 200 mm OAL (PL-2008) Putty Knife- 40 x 200 mm OAL (PK-2040) Shoe Handle Brush- 30 x 255 mm OAL (BR-1004)

Developed 17 Pcs and 11 Pcs Standard HAZMAT/OISD EmergencyPreparedness Kit.

Page 9: An incident is just the tip of the iceberg, a sign of a ...cidm.in/pdf/Day1/3.pdf · OISD-STD -244: Storage and Handling of Petroleum Products at Depots & Terminals. OISD – 144

16‐12‐2019

9

www.pahwametaltech.co.in© Pahwa MetalTech Private Limited

QTi® Digging/Excavation Tools

17

www.pahwametaltech.co.in© Pahwa MetalTech Private Limited

Products Developed for Solid Propellants and Explosives

18

Page 10: An incident is just the tip of the iceberg, a sign of a ...cidm.in/pdf/Day1/3.pdf · OISD-STD -244: Storage and Handling of Petroleum Products at Depots & Terminals. OISD – 144

16‐12‐2019

10

www.pahwametaltech.co.in© Pahwa MetalTech Private Limited 19

Def

ence

& S

pac

eC

he

mic

al

& P

har

ma

Au

to &

A

uto

C

om

p.

Gen

eral

In

du

stry

Oil

& G

as

Our Major Customers

www.pahwametaltech.co.in© Pahwa MetalTech Private Limited

Awards and Recognitions

G.S. Parkhe Award for Innovation in

Entrepreneurship by MCCIA

20

Health & Safety Award by Global Petroleum Show 2019, Canada

Environmentally Friendly MSE by SIDBI & Economic Times India MSE

Awards

Product Innovation Award by Industrial Product Finder

Page 11: An incident is just the tip of the iceberg, a sign of a ...cidm.in/pdf/Day1/3.pdf · OISD-STD -244: Storage and Handling of Petroleum Products at Depots & Terminals. OISD – 144

16‐12‐2019

11

www.pahwametaltech.co.in© Pahwa MetalTech Private Limited

A Global Company from India

21

www.pahwametaltech.co.in© Pahwa MetalTech Private Limited

Contact Us

Office and Manufacturing Unit :

Plot No A-25, Phase-I, MIDC, Chakan, Pune

E-Mail : [email protected]

[email protected]

[email protected]

Phone : +91 84594 82252

Fax : +91 22 6645 9590

Website : www.pahwametaltech.co.in

22

Follow Us On :