A PLAN VIEW DETAIL OF PLAN - SOUNDWALL...soundwall plan and elevation general notes 1 0 6 2 2 b s w...
Transcript of A PLAN VIEW DETAIL OF PLAN - SOUNDWALL...soundwall plan and elevation general notes 1 0 6 2 2 b s w...
BRIDGE SHEET
FILE NUMBER
TOTAL SHEETS
10622-B
96-4-1
STATE OF NEW HAMPSHIREDEPARTMENT OF TRANSPORTATION * BUREAU OF BRIDGE DESIGN
STATE PROJECT
SHEET NO.FEDERAL PROJECT NO.
CHECKED
CHECKED
CHECKED
DATEBY
BTW
BTW
8/04
8/04
BRIDGE NO.TOWN
LOCATION
DESIGNED
DRAWN
QUANTITIES
BY DATEREVISIONS AFTER PROPOSAL
REV. DATE
ISSUE DATE
MANCHESTER
MWS
1/03
CONSULTINGENGINEERS Maine New Hampshire Vermont
email: cld@cldengineers. com www.cldengineers.com
(603) 668-8223 Fax: (603) 668-8802
540 Commercial Street Manchester, NH 03101
Inc.
SOUNDWALL PLAN AND ELEVATION
GENERAL NOTES
1062
2B
SW
D.
DG
N
1/03
SRP
5/03SRP BTW 8/04
218 OF
A000 (270)
ALLARD DRIVE, SECOND STREET, AND TURNER STREET RECONSTRUCTION
96 120
THE BARRIER ON 25’-6"– CHORDS TO THE CURVES.
ON THE CURVES SHOWN. HOWEVER, THE CONTRACTOR MAY CONSTRUCT
6. IT IS INTENDED THAT THE SOUND WALL BARRIERS BE CONSTRUCTED
OF POST SHALL BE 1’-4".
MAXIMUM ALLOWABLE DISTANCE FROM THE TOP OF WALL TO THE TOP
THE TOP OF WALL ELEVATION VARIES ON BOTH SIDES OF A POST THE
THE TOP OF WALL TO TOP OF POST SHALL BE 4". IN THE CASE WHERE
BOTH SIDES OF A POST THE MAXIMUM ALLOWABLE DISTANCE FROM
IN THE CASE WHERE THE TOP OF WALL ELEVATION IS THE SAME ON
5. TRANSITION IN TOP OF WALL ELEVATION SHALL BE AS FOLLOWS:
WITH ANGLE POINTS LESS THAN OR EQUAL TO 20 DEGREES.
HORIZONTALLY ALIGNED TO ACHIEVE PROPOSED WALL ALIGNMENT
PANEL SHALL NOT EXCEED 10 DEGREES. POSTS MAY BE
4. THE ANGLE BETWEEN THE PRECAST CONCRETE POST AND WALL
OF THE TIMBER SOUNDWALL.
3. SEE SHEETS 2, 3 AND 7 0F 21 FOR PLANS SHOWING LAYOUT
2. SEE SPECIAL PROVISION FOR TIMBER REQUIREMENTS.
NECESSARY FOR COMPLETE CONSTRUCTION OF THE WALL AS SHOWN.
BOLTS, NUTS AND WASHERS, AND OTHER ATTACHMENT HARDWARE
POSTS, STEEL BASE PLATES, THREADED REINFORCING, ANCHOR
CONCRETE LEVELING PANEL, CONCRETE GROUT PAD UNDERNEATH
INCLUDE ALL TIMBER, PRECAST CONCRETE POSTS AND PRECAST
1. ITEM 594.2, WOOD PANEL SOUND ABATEMENT WALL SHALL
3’-
6"
4’-
6"
AND CAST-IN-PLACE FOOTING
C PRECAST CONCRETE POST
AND CAST-IN-PLACE FOOTING
C PRECAST CONCRETE POSTL L
12’-9" (TYP.)
2" (MIN.)
CONCRETE BARRIER
CAST-IN-PLACE
JOINT (TYP.)
CONSTRUCTION
SCALE �" = 1’-0"
ELEVATION - SOUNDWALL
BETWEEN POSTS
LEVEL TOP
(TYP.)
(TYP.)
�"
(ITEM 509.2)
SEAL ALL �" GAPS WITH ELASTOMERIC
IN ITEM 594.2)SEALANT (TYP.)(ALL COSTS INCLUDED
LEVELING PANEL
PRECAST CONCRETE
3’-6" 0 CAST-IN-PLACE FOOTING
++8’-
6" _
MI
N.
11’-
6"_
MA
X.
TOP OF BARRIER
PAY LIMITS OF 594.2
TOP OF WALL (SEE
2 AND 3 OF 21)
TABLE BRIDGE SHEET
BRIDGE SHEET 2 AND 3 OF 21)
FINISHED GRADE (SEE TABLE
FINISHED GRADE
6’-4�"–
(TYP.)
NOTE
*
�" (MAX.)
EXPANSION JOINT LAYOUT. SEE GENERAL NOTES.
SHEET 10 OF 21 FOR CONSTRUCTION JOINT AND
SOUNDWALL BARRIER REINFORCMENT PLAN, BRIDGE
THESE DISTANCES MAY VARY SLIGHTLY. SEE THE
* DUE TO THE CURVATURE OF THE SOUNDWALL BARRIER
SCALE �" = 1’-0"
WALL PANEL
2 x 8 TIMBER
PRECAST CONCRETE POST
CONCRETE BARRIER
CAST-IN-PLACE
PLAN - SOUNDWALL
2 x 4 STRONG-BACKS
JOINT (TYP.)
CONSTRUCTION
(TYP.)
A
A
(TYP.)
PLATE
POST BASE
AND 1/3 POINTS
BACK AT PANEL ENDS
INSTALL FRONT AND FOOTING (TYP.)
CAST-IN-PLACE
25’-6"–*
12’-9"
3’-
6"
3’-0"
1’-6" (TYP.)
1’-0"
4’-4"
ANCHOR BOLTS
GROUT PAD
VARIES
SCALE �" = 1’-0"
AND CAST-IN-PLACE FOOTING
C PRECAST CONCRETE POSTL
DETAIL B
POST BASE PLATE (SEAL AROUND
(TYP.)
2’-2"
L
TO B I-293 AND C SB ON-RAMPL L
VARIES
WORK TO BE PERFORMED
PROJECT 10622-C
UNDER CONSTRUCTION
1’-0"
(TYP.)
SECTION A-A
GIVEN TO HERE
PROFILE FINISHED GRADE EL.
1’-0"
(TYP.)
(ITEM 206.1)
EXISTING GROUND
APPROXIMATE
- CUT SECTION
2 x 4 STRONG-BACKS
2 x 8 WALL PANELS
B SOUNDWALL
L
GROUND - FILL SECTION
APPROXIMATE EXISTING
FOOTING (ITEM 509.2)
3’-6" 0 CAST-IN-PLACE
EMBANKMENT-IN-PLACE
PAY LIMITS OF
(COST INCLUDED IN ITEM 594.2)
PRECAST CONCRETE POST
TO B TURNER STEET, B BATH STREET,
WALKER STREET
B SCHOOL STREET, AND B DRIVE TO L L
L
IN ITEM 594.2)
SEALANT. (ALL COSTS INCLUDED
CONCRETE POST WITH ELASTOMERIC
(F)(ITEM 203.6)
BARRIER (ITEM 520.01)
CAST-IN-PLACE CONCRETE
STRUCTURE EXCAVATION
PAY LIMITS OF COMMON
LEVELING PANEL
PRECAST CONCRETE
SHALL BE MADE PRIOR TO PRESSURE TREATMENT)
SHALL BE CUT AT A 45 DEGREE ANGLE. THIS CUT
10d NAILS PER PANEL. TOP OF STRONG-BACKS
OTHER PANELS NAIL USING 2 STAINLESS STEEL
BOLTS AT TOP AND BOTTOM WALL PANELS. AT
(CONNECT USING �" 0 GALVANIZED CARRIAGE
2 x 4 STRONG-BACKS
PANEL - POST CONNECTION
PLAN VIEW DETAIL OF
SCALE 3" = 1’-0"
WALL PANEL
2 x 8 TIMBER
�"
2 x 3 WOOD WALL CAP
SPLITTING)
ELIMINATE ANY
AND PREDRILLED TO
NAILED 1’-0" O.C.
(THE CAP SHALL BE
DETAIL B
SCALE 3" = 1’-0"
BRIDGE SHEET
FILE NUMBER
TOTAL SHEETS
10622-B
96-4-1
STATE OF NEW HAMPSHIREDEPARTMENT OF TRANSPORTATION * BUREAU OF BRIDGE DESIGN
STATE PROJECT
SHEET NO.FEDERAL PROJECT NO.
CHECKED
CHECKED
CHECKED
DATEBY
BTW
BTW
8/04
8/04
BRIDGE NO.TOWN
LOCATION
DESIGNED
DRAWN
QUANTITIES
BY DATEREVISIONS AFTER PROPOSAL
REV. DATE
ISSUE DATE
MANCHESTER
MWS
1/03
CONSULTINGENGINEERS Maine New Hampshire Vermont
email: cld@cldengineers. com www.cldengineers.com
(603) 668-8223 Fax: (603) 668-8802
540 Commercial Street Manchester, NH 03101
Inc.
SOUNDWALL PLAN AND ELEVATION
GENERAL NOTES
1062
2B
SW
D.
DG
N
1/03
SRP
5/03SRP BTW 8/04
218 OF
A000 (270)
ALLARD DRIVE, SECOND STREET, AND TURNER STREET RECONSTRUCTION
96 120
THE BARRIER ON 25’-6"– CHORDS TO THE CURVES.
ON THE CURVES SHOWN. HOWEVER, THE CONTRACTOR MAY CONSTRUCT
6. IT IS INTENDED THAT THE SOUND WALL BARRIERS BE CONSTRUCTED
OF POST SHALL BE 1’-4".
MAXIMUM ALLOWABLE DISTANCE FROM THE TOP OF WALL TO THE TOP
THE TOP OF WALL ELEVATION VARIES ON BOTH SIDES OF A POST THE
THE TOP OF WALL TO TOP OF POST SHALL BE 4". IN THE CASE WHERE
BOTH SIDES OF A POST THE MAXIMUM ALLOWABLE DISTANCE FROM
IN THE CASE WHERE THE TOP OF WALL ELEVATION IS THE SAME ON
5. TRANSITION IN TOP OF WALL ELEVATION SHALL BE AS FOLLOWS:
WITH ANGLE POINTS LESS THAN OR EQUAL TO 20 DEGREES.
HORIZONTALLY ALIGNED TO ACHIEVE PROPOSED WALL ALIGNMENT
PANEL SHALL NOT EXCEED 10 DEGREES. POSTS MAY BE
4. THE ANGLE BETWEEN THE PRECAST CONCRETE POST AND WALL
OF THE TIMBER SOUNDWALL.
3. SEE SHEETS 2, 3 AND 7 0F 21 FOR PLANS SHOWING LAYOUT
2. SEE SPECIAL PROVISION FOR TIMBER REQUIREMENTS.
NECESSARY FOR COMPLETE CONSTRUCTION OF THE WALL AS SHOWN.
BOLTS, NUTS AND WASHERS, AND OTHER ATTACHMENT HARDWARE
POSTS, STEEL BASE PLATES, THREADED REINFORCING, ANCHOR
CONCRETE LEVELING PANEL, CONCRETE GROUT PAD UNDERNEATH
INCLUDE ALL TIMBER, PRECAST CONCRETE POSTS AND PRECAST
1. ITEM 594.2, WOOD PANEL SOUND ABATEMENT WALL SHALL
DATE:
SAMPLE PLAN
USING DETAILS.CLOSELY REVIEW BEFORE
MAY NOT BE CURRENT.NOTE: DETAILS AND NOTES
08-2004
PROJECT. FOR EACHDESIGNED BE
ANCHORAGE SYSTEM SHALLNOTE: BARRIER MOUNTED
manchester.dgn Default 11/14/2013 8:52:59 AM �n18abh�
BRIDGE SHEET
FILE NUMBER
TOTAL SHEETS
10622-B
96-4-1
9 21
STATE OF NEW HAMPSHIREDEPARTMENT OF TRANSPORTATION * BUREAU OF BRIDGE DESIGN
STATE PROJECT
SHEET NO.FEDERAL PROJECT NO.
CHECKED
CHECKED
CHECKED
DATEBY
BTW
BTW
8/04
8/04
BRIDGE NO.
DESIGNED
DRAWN
QUANTITIES
BY DATEREVISIONS AFTER PROPOSAL
REV. DATE
ISSUE DATE
MANCHESTER
SWP
MWS
1/03
TOWN
LOCATION
CONSULTINGENGINEERS Maine New Hampshire Vermont
email: cld@cldengineers. com www.cldengineers.com
(603) 668-8223 Fax: (603) 668-8802
540 Commercial Street Manchester, NH 03101
Inc.
10
622
BS
WD.
DG
N
FOOTING NOTES
BARRIER NOTES
1/03
1.
2.
3.
4.
OF
SWP 5/03 BTW 8/04
A000 (270)
ALL CONCRETE SURFACES, EXCEPT AS NOTED.
ALL REINFORCING STEEL SHALL BE A MINIMUM 6" CLEAR FROM
CONSTRUCTION OF THE SOUNDWALL FOUNDATION.
UTILITY RELOCATION WORK SHALL BE COMPLETED BEFORE
OF FILL SHALL BE IN ACCORDANCE WITH 203.3.7 AND 203.3.8.
TO CONSTRUCTING THE SHAFTS. PLACEMENT AND COMPACTION
EXISTING GROUND, THE EMBANKMENT SHALL BE BUILT PRIOR
WHERE FILL EMBANKMENT IS TO BE CONSTRUCTED ABOVE THE
NECESSARY WILL BE PAID FOR UNDER ITEM 509.3.
ITEM 509.2, DRILLED SHAFTS. REMOVAL OF OBSTRUCTIONS AS
SECTION 509, DRILLED SHAFTS. PAYMENT SHALL BE INCLUDED IN
SHALL BE IN ACCORDANCE WITH THE SPECIAL PROVISION FOR
CONCRETE AND REINFORCING REQUIREMENTS FOR THE FOOTING
FOOTING EXCAVATION AND CONSTRUCTION METHODS, ALONG WITH
97 120
ALLARD DRIVE, SECOND STREET, AND TURNER STREET RECONSTRUCTION
FROM ALL CONCRETE SURFACES.
3. ALL REINFORCING STEEL SHALL BE A MINIMUM 3" CLEAR
JOINT.
25’-6". EVERY THIRD JOINT SHALL BE AN EXPANSION
2. JOINTS IN BARRIER SHALL BE SPACED AT APPROXIMATE
CONCRETE CLASS AA, ITEM 520.01.
1. CONCRETE FOR CAST-IN-PLACE BARRIER SHALL BE
SOUNDWALL BARRIER AND FOOTING DETAILS
14’-0"
2"
CONCRETE BARRIER
CAST-IN-PLACE
ELEVATION - FOOTING
(MIN.)
SCALE �" = 1’-0"
LC CAST-IN-PLACE FOOTING
3’-6"
1’-0"GRADE
FINISHED
#5
BA
RS
AT 1’-0"
2’-11"
6"
(MI
N.)
(SHAFTS NO. 1 - 63)
î
ELEVATION - FOOTING
SCALE �" = 1’-0"
12’-0"
2"
CONCRETE BARRIER
CAST-IN-PLACE
(MIN.)
LC CAST-IN-PLACE FOOTING
3’-6"
1’-0"GRADE
FINISHED
#5
BA
RS
AT 1’-0"
2’-11"
6"
(MI
N.)
(SHAFTS NO. 64 - 131)
î
3’-6"
4’-4"
3’-0"
5"
(TYP.)
3"
(TYP.)
TYPICAL BARRIER SECTION
(TYP.)
7"
3" REVEAL
2’-8"
10"R
84 -00’-00"
55°-00’-00"
SCALE 1" = 1’-0"
(TYP.)
1’-0"
C CAST-IN-PLACE BARRIERL
FOOTING
3’-6" 0 CAST-IN-PLACE
(MIN.)
2"
1’-6"
(TYP.)
(SILANE-SILOXANE)(F)(ITEM 534.3)
PAY LIMITS OF WATER REPELLENT
(ITEM 520.01)
CONCRETE CLASS AA
(T
YP.)
R 1"
SCALE �" = 1’-0"
1’-5" 1’-5"1’-6"
2’-9"
2’-9"
3"
CONCRETE BARRIER
CAST-IN-PLACE
CONCRETE BARRIER
CAST-IN-PLACE
3"
(TYP.)
SECTION THROUGH JOINT
KEY
ELEVATION
EXPANSION JOINT
LOCATION OF
BARRIER SHEAR KEY DETAIL AT EXPANSION JOINT
SCALE �" = 1’-0"
PLAN FOOTING
3’-6"
7’-10" PERIMETER
2’-6" DIAMETER
AT 1’-0"
#5 BARS
PERIMETER
EVENLY AROUND
11 - #9 BARS SPACED
LA
P
= 1’-8"
ALL AROUND
6" CLR.
SCALE 1" = 1’-0"
#7SB1-#7SB5 AT 11�"
1’-11"
(MIN.)
#7SB1-#7SB5 AT 10"
#5SB6 AT 12"
#5SB7 AT 12"
TYPICAL BARRIER REINFORCING SECTION
AT 11�
" (
TY
P.)
#7
SB1-#7
SB
5 (
EF)
�"
�"
1�"
LOCATION OF
�" x�" ELASTOMERIC
�" �" �"
SCALE 1" = 3"
IN ITEM 520.01)
SEALANT (COST INCLUDED
�" CORK (COST INCLUDED
IN ITEM 520.01)
JOINT
EXPANSION
EXPANSION JOINT DETAIL
�"
1"
LOCATION OF
�" �"
SCALE 1" = 3"
CONSTRUCTION JOINT DETAIL
JOINT
CONSTRUCTION
BRIDGE SHEET
FILE NUMBER
TOTAL SHEETS
10622-B
96-4-1
9 21
STATE OF NEW HAMPSHIREDEPARTMENT OF TRANSPORTATION * BUREAU OF BRIDGE DESIGN
STATE PROJECT
SHEET NO.FEDERAL PROJECT NO.
CHECKED
CHECKED
CHECKED
DATEBY
BTW
BTW
8/04
8/04
BRIDGE NO.
DESIGNED
DRAWN
QUANTITIES
BY DATEREVISIONS AFTER PROPOSAL
REV. DATE
ISSUE DATE
MANCHESTER
SWP
MWS
1/03
TOWN
LOCATION
CONSULTINGENGINEERS Maine New Hampshire Vermont
email: cld@cldengineers. com www.cldengineers.com
(603) 668-8223 Fax: (603) 668-8802
540 Commercial Street Manchester, NH 03101
Inc.
10
622
BS
WD.
DG
N
FOOTING NOTES
BARRIER NOTES
1/03
1.
2.
3.
4.
OF
SWP 5/03 BTW 8/04
A000 (270)
ALL CONCRETE SURFACES, EXCEPT AS NOTED.
ALL REINFORCING STEEL SHALL BE A MINIMUM 6" CLEAR FROM
CONSTRUCTION OF THE SOUNDWALL FOUNDATION.
UTILITY RELOCATION WORK SHALL BE COMPLETED BEFORE
OF FILL SHALL BE IN ACCORDANCE WITH 203.3.7 AND 203.3.8.
TO CONSTRUCTING THE SHAFTS. PLACEMENT AND COMPACTION
EXISTING GROUND, THE EMBANKMENT SHALL BE BUILT PRIOR
WHERE FILL EMBANKMENT IS TO BE CONSTRUCTED ABOVE THE
NECESSARY WILL BE PAID FOR UNDER ITEM 509.3.
ITEM 509.2, DRILLED SHAFTS. REMOVAL OF OBSTRUCTIONS AS
SECTION 509, DRILLED SHAFTS. PAYMENT SHALL BE INCLUDED IN
SHALL BE IN ACCORDANCE WITH THE SPECIAL PROVISION FOR
CONCRETE AND REINFORCING REQUIREMENTS FOR THE FOOTING
FOOTING EXCAVATION AND CONSTRUCTION METHODS, ALONG WITH
97 120
ALLARD DRIVE, SECOND STREET, AND TURNER STREET RECONSTRUCTION
FROM ALL CONCRETE SURFACES.
3. ALL REINFORCING STEEL SHALL BE A MINIMUM 3" CLEAR
JOINT.
25’-6". EVERY THIRD JOINT SHALL BE AN EXPANSION
2. JOINTS IN BARRIER SHALL BE SPACED AT APPROXIMATE
CONCRETE CLASS AA, ITEM 520.01.
1. CONCRETE FOR CAST-IN-PLACE BARRIER SHALL BE
SOUNDWALL BARRIER AND FOOTING DETAILS
PROJECT. FOR EACHDESIGNED BE
ANCHORAGE SYSTEM SHALLNOTE: BARRIER MOUNTED
USING DETAILS.CLOSELY REVIEW BEFORE
MAY NOT BE CURRENT.NOTE: DETAILS AND NOTES
DATE:
SAMPLE PLAN
08-2004
manchester.dgn Default 11/14/2013 8:53:22 AM �n18abh�
BRIDGE SHEET
FILE NUMBER
TOTAL SHEETS
10622-B
96-4-1
STATE OF NEW HAMPSHIREDEPARTMENT OF TRANSPORTATION * BUREAU OF BRIDGE DESIGN
STATE PROJECT
SHEET NO.FEDERAL PROJECT NO.
CHECKED
CHECKED
CHECKED
DATEBY
BTW
BTW
8/04
8/04
BRIDGE NO.
DESIGNED
DRAWN
QUANTITIES
BY DATEREVISIONS AFTER PROPOSAL
REV. DATE
ISSUE DATE
MANCHESTER
SWP
MWS
1/03
TOWN
LOCATION
CONSULTINGENGINEERS Maine New Hampshire Vermont
email: cld@cldengineers. com www.cldengineers.com
(603) 668-8223 Fax: (603) 668-8802
540 Commercial Street Manchester, NH 03101
Inc.
1062
2B
SW
D.
DG
N
POST NOTES
CONNECTION NOTES
1/03
OF
SWP 5/03 BTW 8/04
11 21
PRECAST CONCRETE PANEL NOTES
TO PREVENT GAPS.
BE FREE FROM PITS OR HOLES AND SHALL BE CAST SMOOTH
FREE OF DEFECTS. THE TOP OF LEVELING PANEL SHALL
2. THE LEVELING PANELS SHALL BE 4" THICK AND SHALL BE
28 DAY COMPRESSIVE STRENGTH OF 4000 PSI.
SPECIFICATIONS. CONCRETE SHALL HAVE A MINIMUM
REQUIRMENTS OF SECTION 520 OF THE STANDARD
1. ALL CONCRETE FOR LEVELING PANELS SHALL MEET THE
A000 (270) 99 120
SOUNDWALL DETAILS
ALLARD DRIVE, SECOND STREET, AND TURNER STREET RECONSTRUCTION
THE POST.
OF THE THREADS SHALL EXTEND BEYOND THE BOTTOM OF
BE THREADED TO THE SPECIFIED SIZE. 3.5 INCHES
LAST 4 INCHES OF THE REINFORCING STEEL SHALL
MEET THE REQUIREMENTS OF SECTION 550.2.5. THE
3. EXCEPT AS NOTED, VERTICAL REINFORCING BARS SHALL
TIE BARS MAY BE EPOXY COATED OR GALVANIZED.
SECTION 544 OF THE NHDOT STANDARD SPECIFICATIONS.
GALVANIZED, AND SHALL MEET THE REQUIREMENTS OF
2. ALL STEEL REINFORCING SHALL BE GRADE 60 STEEL,
STRENGTH OF 4000 PSI.
CONCRETE SHALL HAVE A MINIMUM 28 DAY COMPRESSIVE
OF SECTION 520 OF THE STANDARD SPECIFICATIONS.
1. ALL CONCRETE FOR POSTS SHALL MEET THE REQUIREMENTS
HIGH STRENGTH, NON-SHRINK GROUT.
7. GROUT THE AREAS UNDERNEATH THE POSTS WITH APPROVED
COST SUBSIDIARY TO ITEM 594.2.
ELASTOMERIC SEALANT AFTER POST INSTALLATION. ALL
6. HOLES IN BASE PLATES SHALL BE FILLED FLUSH WITH
SHALL BE PROPERLY STORED.
AND AASHTO M111 (ASTM A123). GALVANIZED MATERIAL
FABRICATION IN CONFORMANCE TO AASHTO M232 (ASTM A153)
5. ALL STEEL COMPONENTS SHALL BE GALVANIZED AFTER
CONCRETE BARRIER PRIOR TO GROUTING.
4. ANCHOR BOLTS SHALL EXTEND 7" BEYOND THE TOP OF THE
EXCEPT AS NOTED.
SECTION 550.2.5 OF THE NHDOT STANDARD SPECIFICATIONS,
3. ANCHOR BOLTS SHALL BE FABRICATED IN ACCORDANCE WITH
AND WASHERS SHALL BE GALVANIZED.
OF ASTM F436 AND SHALL BE MADE OF HARDENED STEEL. NUTS
SHALL BE TYPE 1 WASHERS AND SHALL MEET THE REQUIREMENTS
2. NUTS SHALL CONFORM TO ASTM A563, GRADE A. THE WASHERS
SHALL BE ASTM A572, GRADE 50 GALVANIZED.
OF SECTION 550 OF THE STANDARD SPECIFICATIONS. STEEL
1. THE STEEL FOR THE BASE PLATE SHALL MEET THE REQUIREMENTS
1’-4"
5�
"
4�
"
(T
YP.)
1’-2"
OUTSIDE CORNERS)
�" CHAMFER (TYP.
(T
YP.)
3"
(TYP.)
POST DETAIL
(T
YP.)
SCALE 2" = 1’-0"
(TYPICAL ALL POSTS)
= �
R
(TYP.)
�"
(TYP.)(TYP.)(TYP.) (TYP.)
3" 4"4" 3"
(THREADED TO 1" DIA.)
#9 BARS (TYP.)
(TYP.)
3"
#3 TIE BARS (TYP.)
VERTICALLY)
(SPACE AT 1’-0"
10"
1’-6"
2’-0�
"
1�" x 18" x 24�"
BASE PLATE
7�
"10"
4"5"
9"
2�
"
POST BOLTS (TYP.)
1�" HOLES FOR
1�" x 2�"
ANCHOR BOLTS (TYP.)
SLOTTED HOLES FOR
(T
YP.)
(TYP.) (TYP.)
(TYP.)
BASE PLATE DETAIL
C C
SCALE 2" = 1’-0"
(T
YP.)
1’-6"
SECTION C-C
1�"
SCALE 2" = 1’-0"
BAR (GALVANIZED)
#9 STEEL REINFORCING
7" CUT OR
ROLLED THREADS
1"
SCALE 3" = 1’-0"
ANCHOR BOLT DETAIL
(APPROX.)
1�" O.D.3’-0"
BARRIER
CONCRETE
(TYP.)
ANCHOR BOLT
BASE PLATE
GROUT PAD
AND WASHERS
ANCHOR NUTS
SCALE 2" = 1’-0"
CONNECTION DETAIL
4�
"
POST REINFORCING
7"
3�"
6�
"�
"
1�"
�"
MOST WALL PANEL
NO TONGUE IN UPPER
APPROXIMATELY �" LARGER
SCALE 1" = 1"
TIMBER WALL PANEL DETAIL
�"
IN LOWERMOST PANEL)
CONSTRUCTION (NO GROOVE
THAN TONGUE FOR EASE OF
SCALE �" = 1’-0"
12’-0"
4�"
TO SLOPE OF GRADE
VARIES ACCORDING
5"
(TYP.)
(TYP.)
2 x 4 STRONG-BACKS
WALL PANELS
2 X 8 TIMBER
PANEL ON CONCRETE BARRIER
TYPICAL PRECAST CONCRETE LEVELING 4" x 4" (W6 x W6)
WELDED WIRE FABRIC
BARRIER
SLOPE OF CONCRETE
VARIES TO MATCH
TOP OF THE PRECAST CONCRETE
PRECAST CONCRETE POSTS.
TRUE AND LEVEL BETWEEN THE
LEVELING PANEL SHALL BE SET
(MIN.)
8�"
(TYP.)
4�"
NOTE: PANEL IS 4" THICK
2�"
1"
_
1�
"
PANEL SHALL HAVE NO TONGUE
GROOVE, UPPERMOST WALL
NOTE: WALL CAP SHALL HAVE NO
+
1�
"1�
"
1" = 2"
WALL CAP DETAILS
ELEVATION VIEW END VIEW
PLAN VIEW
25°-00’-00"
1�
"
BRIDGE SHEET
FILE NUMBER
TOTAL SHEETS
10622-B
96-4-1
STATE OF NEW HAMPSHIREDEPARTMENT OF TRANSPORTATION * BUREAU OF BRIDGE DESIGN
STATE PROJECT
SHEET NO.FEDERAL PROJECT NO.
CHECKED
CHECKED
CHECKED
DATEBY
BTW
BTW
8/04
8/04
BRIDGE NO.
DESIGNED
DRAWN
QUANTITIES
BY DATEREVISIONS AFTER PROPOSAL
REV. DATE
ISSUE DATE
MANCHESTER
SWP
MWS
1/03
TOWN
LOCATION
CONSULTINGENGINEERS Maine New Hampshire Vermont
email: cld@cldengineers. com www.cldengineers.com
(603) 668-8223 Fax: (603) 668-8802
540 Commercial Street Manchester, NH 03101
Inc.
1062
2B
SW
D.
DG
N
POST NOTES
CONNECTION NOTES
1/03
OF
SWP 5/03 BTW 8/04
11 21
PRECAST CONCRETE PANEL NOTES
TO PREVENT GAPS.
BE FREE FROM PITS OR HOLES AND SHALL BE CAST SMOOTH
FREE OF DEFECTS. THE TOP OF LEVELING PANEL SHALL
2. THE LEVELING PANELS SHALL BE 4" THICK AND SHALL BE
28 DAY COMPRESSIVE STRENGTH OF 4000 PSI.
SPECIFICATIONS. CONCRETE SHALL HAVE A MINIMUM
REQUIRMENTS OF SECTION 520 OF THE STANDARD
1. ALL CONCRETE FOR LEVELING PANELS SHALL MEET THE
A000 (270) 99 120
SOUNDWALL DETAILS
ALLARD DRIVE, SECOND STREET, AND TURNER STREET RECONSTRUCTION
THE POST.
OF THE THREADS SHALL EXTEND BEYOND THE BOTTOM OF
BE THREADED TO THE SPECIFIED SIZE. 3.5 INCHES
LAST 4 INCHES OF THE REINFORCING STEEL SHALL
MEET THE REQUIREMENTS OF SECTION 550.2.5. THE
3. EXCEPT AS NOTED, VERTICAL REINFORCING BARS SHALL
TIE BARS MAY BE EPOXY COATED OR GALVANIZED.
SECTION 544 OF THE NHDOT STANDARD SPECIFICATIONS.
GALVANIZED, AND SHALL MEET THE REQUIREMENTS OF
2. ALL STEEL REINFORCING SHALL BE GRADE 60 STEEL,
STRENGTH OF 4000 PSI.
CONCRETE SHALL HAVE A MINIMUM 28 DAY COMPRESSIVE
OF SECTION 520 OF THE STANDARD SPECIFICATIONS.
1. ALL CONCRETE FOR POSTS SHALL MEET THE REQUIREMENTS
HIGH STRENGTH, NON-SHRINK GROUT.
7. GROUT THE AREAS UNDERNEATH THE POSTS WITH APPROVED
COST SUBSIDIARY TO ITEM 594.2.
ELASTOMERIC SEALANT AFTER POST INSTALLATION. ALL
6. HOLES IN BASE PLATES SHALL BE FILLED FLUSH WITH
SHALL BE PROPERLY STORED.
AND AASHTO M111 (ASTM A123). GALVANIZED MATERIAL
FABRICATION IN CONFORMANCE TO AASHTO M232 (ASTM A153)
5. ALL STEEL COMPONENTS SHALL BE GALVANIZED AFTER
CONCRETE BARRIER PRIOR TO GROUTING.
4. ANCHOR BOLTS SHALL EXTEND 7" BEYOND THE TOP OF THE
EXCEPT AS NOTED.
SECTION 550.2.5 OF THE NHDOT STANDARD SPECIFICATIONS,
3. ANCHOR BOLTS SHALL BE FABRICATED IN ACCORDANCE WITH
AND WASHERS SHALL BE GALVANIZED.
OF ASTM F436 AND SHALL BE MADE OF HARDENED STEEL. NUTS
SHALL BE TYPE 1 WASHERS AND SHALL MEET THE REQUIREMENTS
2. NUTS SHALL CONFORM TO ASTM A563, GRADE A. THE WASHERS
SHALL BE ASTM A572, GRADE 50 GALVANIZED.
OF SECTION 550 OF THE STANDARD SPECIFICATIONS. STEEL
1. THE STEEL FOR THE BASE PLATE SHALL MEET THE REQUIREMENTS
DATE:
SAMPLE PLAN
08-2004
PROJECT. FOR EACHDESIGNED BE
ANCHORAGE SYSTEM SHALLNOTE: BARRIER MOUNTED
USING DETAILS.CLOSELY REVIEW BEFORE
MAY NOT BE CURRENT.NOTE: DETAILS AND NOTES
manchester.dgn Default 11/14/2013 8:53:43 AM �n18abh�
BRIDGE SHEET
FILE NUMBER
TOTAL SHEETS
10622-B
96-4-1
STATE OF NEW HAMPSHIREDEPARTMENT OF TRANSPORTATION * BUREAU OF BRIDGE DESIGN
STATE PROJECT
SHEET NO.FEDERAL PROJECT NO.
CHECKED
CHECKED
CHECKED
DATEBY
BTW
BTW
8/04
8/04
BRIDGE NO.
DESIGNED
DRAWN
QUANTITIES
BY DATEREVISIONS AFTER PROPOSAL
REV. DATE
ISSUE DATE
MANCHESTER
SWP
MWS
1/03
TOWN
LOCATION
1/03
OF
SWP 5/03 BTW 8/04
10 21
A000 (270)
CONSULTINGENGINEERS Maine New Hampshire Vermont
email: cld@cldengineers. com www.cldengineers.com
(603) 668-8223 Fax: (603) 668-8802
540 Commercial Street Manchester, NH 03101
Inc.
1062
2B
SW
D.
DG
N
SOUNDWALL BARRIER REINFORCEMENT PLAN
LEGEND
C = CONTRACTION JOINT
E = EXPANSION JOINT
EF = EACH FACE
FF = FAR FACE
NF = NEAR FACE
98 120
ALLARD DRIVE, SECOND STREET, AND TURNER STREET RECONSTRUCTION
16’-11� "
25’-6�" 25’-6�"
8’-6�
"
19’-
0"
6’-6�
"
300 #7SB3 AT 20 LOCATIONS
4’-5"
(TYP.)
34 #5SB7 AT 12" (17 EF)
(MATCH W/ #5SB6 )
34 #5SB6 AT 12" (17 EF)
3328 #5SB7 AT 12" (52 BETWEEN JOINTS, 26 EF)
3328 #5SB6 AT 12" (52 BETWEEN JOINTS, 26 EF)
(MATCH W/ #5SB6 )
SOUNDWALL BASE LINE
NOTE: DIMENSIONS GIVEN ALONG THE
7°-7’-30"
18 #
5SB6
AT 12
" (9
EF)
SOUNDWALL BARRIER REINFORCING PLAN
SCALE �" = 1’-0"
SECTION, SEE SHEET 9 OF 21.
** PLACE PER TYPICAL BARRIER
CC E C
C
E
C
25’-6�" = 791’-1�"
31 SPACES AT
18 #
5SB7
AT 12
"
W/ #
5SB6 )
(9EF)
(MATCH
25’-6�" = 638’-0�"
25 SPACES AT
5 SPACES
AT
BARRIER
STA. 5
16+5
8.80
END OF
SOUNDWALL
BARRIER STA. 500+00
BEGIN SOUNDWALL
BARRIER AND BASE LINE
FACE OF SOUNDWALL
127’-7�
"
25’-
6�"
=
À SHAFT
(TYP.)
2’-2"
3 BOTTOM, 4 TOP) **
15 #7SB1 (4 EF,
3 BOTTOM, 4 TOP) **
(15 PER LOCATION, 4 EF,
(TYP.)
#5SB6
LOCATION, 4 EF, 3 BOTTOM, 4 TOP) **
645 #7SB2 AT 43 LOCATIONS (15 PER
15 #7SB5 AT
4 TOP) **
(4EF, 3 BOTTOM,
3 BOTTOM, 4 TOP) **
15 #7SB4 AT (4EF,
(TYP.)
#5SB7
BRIDGE SHEET
FILE NUMBER
TOTAL SHEETS
10622-B
96-4-1
STATE OF NEW HAMPSHIREDEPARTMENT OF TRANSPORTATION * BUREAU OF BRIDGE DESIGN
STATE PROJECT
SHEET NO.FEDERAL PROJECT NO.
CHECKED
CHECKED
CHECKED
DATEBY
BTW
BTW
8/04
8/04
BRIDGE NO.
DESIGNED
DRAWN
QUANTITIES
BY DATEREVISIONS AFTER PROPOSAL
REV. DATE
ISSUE DATE
MANCHESTER
SWP
MWS
1/03
TOWN
LOCATION
1/03
OF
SWP 5/03 BTW 8/04
10 21
A000 (270)
CONSULTINGENGINEERS Maine New Hampshire Vermont
email: cld@cldengineers. com www.cldengineers.com
(603) 668-8223 Fax: (603) 668-8802
540 Commercial Street Manchester, NH 03101
Inc.
1062
2B
SW
D.
DG
N
SOUNDWALL BARRIER REINFORCEMENT PLAN
LEGEND
C = CONTRACTION JOINT
E = EXPANSION JOINT
EF = EACH FACE
FF = FAR FACE
NF = NEAR FACE
98 120
ALLARD DRIVE, SECOND STREET, AND TURNER STREET RECONSTRUCTION
DATE:
SAMPLE PLAN
08-2004
PROJECT. FOR EACHDESIGNED BE
ANCHORAGE SYSTEM SHALLNOTE: BARRIER MOUNTED
USING DETAILS.CLOSELY REVIEW BEFORE
MAY NOT BE CURRENT.NOTE: DETAILS AND NOTES
manchester.dgn Default 11/14/2013 8:54:09 AM �n18abh�