90BF6D645B4C4EDCBB155354B3FEE58F.ashx
-
Upload
freakyboys -
Category
Documents
-
view
19 -
download
3
description
Transcript of 90BF6D645B4C4EDCBB155354B3FEE58F.ashx
-
Sample & Assay Technologies
PCR From Setup to Cleanup
A beginners guide with useful tips and tricks
-
2 www.qiagen.com BRO PCR beginner hints 05/2013
Guidelines for PCRPCR amplification is performed routinely and thousands of PCR protocols have been developed,
yet researchers still encounter technical difficulties with PCR experiments and often fail to obtain
specific amplification products. Although there are several different challenges (e.g., smearing, low
yield, and nonspecific amplification), there are two main reasons for PCR failure or poor results:
the specificity of the reaction and template secondary structure.
PCR is both a thermodynamic and an enzymatic process. Successful PCR requires amplification
and detection under optimal conditions and each reaction component can affect the result. The
annealing step is critical for high PCR specificity. When primers anneal to the template with high
specificity, this leads to high yields of specific PCR products and increases the sensitivity of the
amplification reaction. However, due to the high primer concentration in the reaction, primers
will also hybridize to non-complementary sequences with mismatches. If the primers anneal
to the template sequence with low specificity, amplification of nonspecific PCR products and
primerdimers may occur. Factors critical in successful PCR include primer design and the reaction
chemistry used.
PCR primer designOptimal primer sequences and appropriate primer concentrations are essential for maximal
specificity and efficiency in PCR. The PCR section of the QIAGEN Protocols and Applications
Guide provides more information about primer design.
The following points should be considered when designing PCR primers and are common to all
types of PCR:
Melting temperature (Tm) calculation: 2C x (A+T) + 4C x (G+C)
Avoid complementarity in the 23 bases at the 3' end of the primer pairs
Avoid mismatches between the 3' end of the primer and the template
Avoid runs of 3 or more Cs or Gs at the 3' end of the primer
Avoid complementarity within primers and between the primer pair
PCR
The invention of the polymerase chain reaction (PCR) by K. Mullis and co-workers in 1985 revolutionized molecular biology
and molecular medicine. Major research areas, such as biomarker discovery, gene regulation, and cancer research, are
challenging todays PCR technologies with more demanding requirements. These include the need for increased throughput,
higher assay sensitivity, and reliable data analysis. Assay development and evaluation, reproducibility of data, and time to
result are still major problems encountered by researchers.
-
BRO PCR beginner hints 05/2013 Sample & Assay Technologies 3
Avoid a T as ultimate base at the 3' end
Ensure primer sequence is unique for the template sequence
Use a concentration of 0.11.0 M of each primer. For many applications,a primer
concentration of 0.2 M will be sufficient
Lyophilized primers should be dissolved in a small volume of distilled water or TE to make a
concentrated stock solution. Prepare small aliquots of working solutions containing 10 pmol/l to
avoid repeated thawing and freezing. Store all primer solutions at 20C. Primer quality can be
checked on a denaturing polyacrylamide gel; a single band should be seen.
PCR conditionsThe primer and Mg2+ concentration in the PCR buffer and annealing temperature of the reaction
may need to be optimized for each primer pair for efficient PCR. In addition, PCR efficiency can
be improved by additives that promote DNA polymerase stability and processivity or increase
hybridization stringency, and by using strategies that reduce nonspecific primertemplate
interactions. Use of high-purity reagents is also essential for successful PCR, especially for
amplification of rare templates, for example, single copy genes in genomic DNA or pathogenic
viral DNA sequences in genomic DNA isolated from an infected organism.
Inclusion of control reactions is essential for monitoring the success of PCR reactions. Wherever
possible, a positive control should be included to check that the PCR conditions used can
successfully amplify the target sequence. As PCR is extremely sensitive, requiring only a few copies
of target template, a negative control containing no template DNA should always be included to
ensure that the solutions used for PCR have not become contaminated with the template DNA.
Primer annealing specificity and PCR buffersIn PCR, annealing occurs between the primers and complementary DNA sequences in the template.
Primer annealing must be specific for successful amplification. Due to the high concentration of
primers necessary for efficient hybridization during short annealing times, primers can anneal to
non-complementary sequences. Amplification of products from nonspecific annealing competes
with specific amplification and may drastically reduce the yield of the specific product.
The success of PCR largely depends on maintaining a high ratio of specific to nonspecific annealing
of the primer molecules. Annealing is primarily influenced by the components of the PCR buffer (in
particular the cations) and annealing temperature. Special cation combinations can maintain high
primer annealing specificity over a broad range of annealing temperatures. This eliminates the
need for optimization of annealing temperatures for each individual primertemplate system and
also allows the use of non-ideal PCR assays with different primer annealing temperatures.
Tip: PCR setup should be performed in a separate area from PCR analysis to ensure that reagents used for PCR do not become contaminated with PCR products. Similarly, pipets used for analysis of PCR products should never be used for setting up PCR.
-
4 www.qiagen.com BRO PCR beginner hints 05/2013
A balanced combination of cations promotes specific primer annealing
Cations in commonly used PCR buffers bind to the negatively charged
phosphate groups on the DNA backbone and thereby neutralize these
negative charges. This weakens the electrorepulsive forces between the
DNA template and primer molecule leading to more stable hybridization
of the primer. Most commercially available PCR buffers contain only one
monovalent cation, K+, which stabilizes both specific and nonspecific
primer annealing. This often results in smearing and nonspecific DNA
amplification, which leads to lower product yields. QIAGEN has found
that the balanced combination of K+ and NH4+ used in all QIAGEN
PCR buffers provided with all QIAGEN PCR enzyme and master mix kits
strongly increases primer annealing specificity. The improved specificity
is caused by ammonium ions destabilizing the weak hydrogen bonds at
mismatched bases (Figures 1 and 2).
Discover more about optimized PCR conditions with QIAGENs PCR Kits.
Annealing temperatureThe optimal primer annealing temperature is dependent on the base
composition (i.e., the proportion of A, T, G, and C nucleotides), primer
concentration, and ionic reaction environment. Therefore annealing
temperature needs to be optimized for each primer pair.
Magnesium ion concentrationMagnesium ions are a critical DNA polymerase cofactor necessary for
enzyme activity. Mg2+ binds to DNA, primers, and nucleotides contained
in the amplification reaction. The Mg2+ concentration is generally
higher than that of dNTPs and primers, and some optimization may be
necessary for different template and primer concentrations. A higher than
optimal concentration of Mg2+ can stabilize nonspecific binding and is
often indicated by decreased yields of specific PCR products and the
appearance of background smear or other PCR artifacts.
Figure 1. Animation on QIAGENs unique PCR buffer
system. Watch the video on www.qiagen.com/PCR-video.
Figure 2. NH4+ and K+ cations in QIAGEN PCR buffers
increases specific primer annealing.
K+ binds to the phosphate groups (P) on the DNA backbone, stabilizing the annealing of the primers to the template. NH4
+, which exists both as the ammonium ion and as ammonia under thermal-cycling conditions, can interact with the hydrogen bonds between the bases (B), destabilizing principally the weak hydrogen bonds at mismatched bases. The combined effect of the two cations maintains the high ratio of specific to non-specific primertemplate binding over a wide temperature range.
NH3 + H+
DestabilizationNH4+
Stabilization Stabilization
Weak hydrogen band (e.g., between C and T nucleotides)Strong hydrogen band (e.g., between A and T nucleotides)
B H
H
H
H
P
K+
P P
P
B B
B
K+
K+
K+
Tip: There is no need to calculate annealing temperature when using
QIAGEN PCR kits, as they work over a wide temperature range!
-
BRO PCR beginner hints 05/2013 Sample & Assay Technologies 5
PCR additivesVarious PCR additives or enhancers are available for improving PCR results. It is claimed that these reagents relieve secondary
DNA structure (e.g., hairpin loops in GC-rich regions or in long amplification products), lower template melting temperature,
enhance enzyme processivity, stabilize DNA polymerases, or prevent attachment of polymerases to plasticware.
Commonly used PCR additives include dimethyl sulfoxide (DMSO), bovine serum albumin (BSA), and glycerol.
Tip: Q Solution QIAGENs PCR enhancer for difficult templates is found in: QIAGEN Multiplex PCR kits, Type-it kits, QIAGEN Fast Cycling PCR kits, QIAGEN LongRange PCR Kit, HotStar HiFidelity PCR Kits, and with all standard DNA polymerases.
Q-Solution
This innovative PCR additive facilitates amplification of difficult templates
by modifying the melting behavior of DNA. Use of this unique reagent
will often enable or improve suboptimal PCR. Unlike DMSO and other
PCR additives, Q-Solution is used at a defined working concentration
with any primertemplate system and is not toxic (Figure 3).
Loading dyesQIAGENs PCR kits are supplied with CoralLoad PCR Buffer, which
has all of the advantages of QIAGEN PCR Buffer, but can also be used
to directly load the PCR reaction onto an agarose gel without the need
for an additional gel loading buffer. CoralLoad PCR Buffer provides
the same high PCR specificity and minimal reaction optimization as the
conventional QIAGEN PCR Buffer. Additionally, it contains two marker
dyes an orange dye and a red dye that facilitate estimation of
DNA migration distance and optimization of agarose gel run time (see
Figure 5 on page 13). The buffer ensures improved pipetting visibility
and enables direct loading of PCR products onto a gel, for enhanced
convenience. Since the PCR results are colored for convenience, for
some sensitive downstream applications, it may be necessary to clean
up the DNA (see pages 2028 for more information).
Figure 3. Influence of Q-Solution on PCR success. A 4.8 kb fragment was amplified in standard reactions using TopTaq DNA Polymerase with or without Q-Solution. M: marker. Specific amplification was achieved only in reactions containing Q-Solution.
M with Q-Solution without Q-Solution
4.8 kb
-
6 www.qiagen.com BRO PCR beginner hints 05/2013
QIAGEN solution: QIAGEN DNA Taq Polymerase for standard and specialized PCR applications
Primer sequence:
Avoid degeneracy in the 3 nucleotides at the 3' end, i.e., if possible
use Met- or Trp-encoding triplets at the 3' end
To increase primertemplate binding efficiency, reduce degeneracy
by allowing some mismatches between the primer and template,
especially towards the 5' end, but not the 3' end
Try to design primers with less than 4-fold degeneracy at any given
position
Primer concentration:
Begin PCR with a primer concentration of 0.2 M
In case of poor PCR efficiency, increase primer concentrations in
increments of 0.25 M until satisfactory results are obtained
Enzymes used in PCRSeveral types of thermostable DNA polymerases are available for use in
PCR, providing a choice of enzymatic properties.
Taq DNA polymerase, isolated from the eubacterium Thermus aquaticus,
is the most commonly used enzyme for standard end-point PCR. The
robustness of this enzyme allows its use in many different PCR assays.
However, as this enzyme is active at room temperature, it is necessary to
perform reaction setup on ice to avoid nonspecific amplification.
A number of modifications of the original PCR polymerase Taq DNA
polymerase are now available for different downstream application
needs, such as hot-start, single-cell, high-fidelity, or multiplex PCR. With
an average error rate of 1 in 10,000 nucleotides, Taq DNA polymerase
and its variants are less accurate than thermostable enzymes of DNA
polymerase family B.
Guidelines for degenerate primer design and usePCR primer sequences are often deduced from amino acid sequences if the exact nucleotide sequence of their target is
unknown. However, because of the degeneracy of the genetic code, the deduced sequences may vary at one or more
positions. A common solution in these cases is to use a degenerate primer, which is a mixture of similar primers that have
different bases at the variable positions. Using degenerate primers can lead to difficulties optimizing PCR assays: within
a degenerate primer mixture only a limited number of primer molecules are complementary to the template; the melting
temperature (Tm) of primer sequences may vary significantly; and the sequences of some primers can be complementary
to those of others. For these reasons, amplification conditions are required that minimize nonspecific primertemplate and
primerprimer interactions. The following guidance may help when designing and using degenerate primers.
-
BRO PCR beginner hints 05/2013 Sample & Assay Technologies 7
However, due to its versatility, Taq DNA polymerase is still the enzyme
of choice for most routine applications and when used with a stringent
hot-start, is suitable for several challenging PCR applications.
Hot-start DNA polymeraseWhen amplification reaction setup is performed at room temperature,
primers can bind nonspecifically to each other, forming primerdimers.
During amplification cycles, primerdimers can be extended to produce
nonspecific products, which reduces specific product yield. For more
challenging PCR applications, the use of hot-start PCR is crucial for
successful specific results. To produce hot-start DNA polymerases,
Taq DNA polymerase activity can be inhibited at lower temperatures
with antibodies or, more effectively, with chemical modifiers that form
covalent bonds with amino acids in the polymerase. The chemical
modification leads to complete inactivation of the polymerase until the
covalent bonds are broken during the initial heat activation step. In
contrast, in antibody-mediated hot-start procedures, antibodies bind to
the polymerase by relatively weak non-covalent forces, which leaves
some polymerase molecules in their active state. This sometimes leads
to nonspecific primer extension products that can be further amplified
during PCR. These products appear as smearing or incorrectly sized
fragments when run on an agarose gel.
High-fidelity DNA polymeraseUnlike standard DNA polymerases (such as Taq DNA polymerase), high-
fidelity PCR enzymes generally provide a 3' to 5' exonuclease activity for
removing incorrectly incorporated bases. High-fidelity PCR enzymes are
ideally suited to applications requiring a low error rate, such as cloning,
sequencing, and site-directed mutagenesis. However, if the enzyme is
not provided in a hot-start version, the 3' to 5' exonuclease activity
can degrade primers during PCR setup and the early stages of PCR.
Nonspecific priming caused by shortened primers can result in smearing
on a gel or amplification failure especially when using low amounts of
template. It should be noted that the proofreading function often causes
high-fidelity enzymes to work more slowly than other DNA polymerases.
In addition, the A-addition function required for direct UA- or TA-cloning
is strongly reduced, resulting in the need for blunt-end cloning with lower
ligation and transformation efficiency.
QIAGEN solution: HotStarTaq Plus DNA Polymerase for fast and highly specific amplification in all applications
QIAGEN solution: HotStar HiFidelity Polymerase Kit the only high-fidelity kit producing sticky ends for simple UA/TA cloning procedures for highly sensitive and reliable high-fidelity hot-start PCR
-
8 www.qiagen.com BRO PCR beginner hints 05/2013
Tip: Proofreading DNA polymerases contain an inherent 3' to 5' exonuclease activity that removes base-pair mismatches. Adding a small amount of a proofreading DNA polymerase to the PCR mixture therefore significantly improves the amplification efficiency of longer PCR products.
Optimizing 3' to 5' exonuclease activityTaq DNA Polymerase introduces more errors into the PCR product while
copying the template than do so-called proofreading DNA polymerases.
Once a mismatch occurs during synthesis, Taq DNA polymerase will
either extend the mismatched strand or fall off the template strand,
leading to mutated or incomplete PCR products, respectively. Although
this does not generally affect PCR efficiency when amplifying shorter
PCR fragments, amplification of longer PCR products can be significantly
impaired by mismatches introduced during DNA synthesis.
PCR cycling In theory, each PCR cycle doubles the amount of amplicon in the
reaction. Therefore, 10 cycles multiply the amplicon by a factor of
~1000 and so on.
Each PCR cycle consists of template denaturation, primer annealing, and
primer extension. If the temperatures for annealing and extension are
similar, these two processes can be combined. Each stage of the cycle
must be optimized in terms of time and temperature for each template
and primer pair combination.
After the required number of cycles has been completed (see the PCR
section of the QIAGEN Protocols and Applications Guide for more
information about cycle numbers), the amplified product may be
analyzed or used in downstream applications.
-
BRO PCR beginner hints 05/2013 Sample & Assay Technologies 9
QIAGEN solution: QIAGEN LongRange PCR Kit for sensitive and accurate long-range PCR up to 20 kb
Amplification of long PCR productsAmplification of PCR products longer than 34 kb is often compromised
by nonspecific primer annealing, suboptimal cycling conditions, and
secondary structures in the DNA template. Lengthy optimization is often
necessary, by varying factors such as cycling conditions, primer and
dNTP concentrations, and special additives.
Optimizing cycling conditionsWhile depurination is usually not a problem in standard PCR, it can
significantly influence the amplification of longer PCR fragments. This
is because longer templates are proportionally more depurinated than
shorter ones. For this reason, very short denaturation steps of only 10
seconds give higher yields and no background smearing compared
to denaturation steps of 30 seconds or 1 minute (which leads to PCR
failure; Figure 4). Extensive depurination is also observed during the final
extension step. Therefore, using a lower extension temperature of 68C
instead of 72C dramatically improves yield of longer amplification
products.
The PCR section of the QIAGEN Protocols and Applications Guide
provides more information about cycling conditions for longer PCR
products.
7.3 kb
M 1 2 3 M 72C 68CA B
Figure 4. Effect of cycling conditions. To illustrate the effects of prolonged heating of the DNA template or the DNA polymerase, three different PCR cycling programs were used to amplify a 7.3 kb fragment of the human interleukin 9 receptor gene. 1: Each PCR cycle had a 60-second denaturation step at 94C. 2: A reaction mixture containing Taq DNA Polymerase but lacking the template DNA was incubated at 94C for 30 minutes; the template DNA was then added and the PCR cycling program started, using 10-second 94C denaturation steps. 3: The PCR cycling program was comparable to 2, except that there was no additional prior incubation. The 7.3 kb PCR product could only be amplified when the temperature of the extension step was lowered from 72C to 68C. M: markers. Results from duplicate PCR amplifications are shown.
B
A
-
10 www.qiagen.com BRO PCR beginner hints 05/2013
Frequently asked questions
How can I tell if I have primerdimers in my PCR reaction?
In non-quantitative endpoint PCR, primerdimers will appear as a more or less faint smear on an
agarose gel, below the product band of interest.
Must I use CoralLoad Gel loading dye when using QIAGENs HotStarTaq Plus DNA Polymerase?
No. HotStarTaq Plus DNA Polymerase is supplied with conventional QIAGEN PCR Buffer and
CoralLoad PCR Buffer in separate vials. Both buffers minimize nonspecific amplification products,
primerdimers, and background.
CoralLoad PCR Buffer has all of the advantages of QIAGEN PCR Buffer, but can also be used to
directly load the PCR reaction onto an agarose gel without the need to add a gel loading buffer.
How comparable is CoralLoad gel loading dye contained in various QIAGEN PCR Kits to Sigma
Red?
CoralLoad gel tracking dye contained in Taq, HotStarTaq Plus, TopTaq DNA Polymerase and
TopTaq Master Mix Kits separates into 2 fragment-size dependent colors (orange and red) when
loaded onto an agarose gel. Sigma Red buffer only has one color which is harder to visualize.
PCR troubleshooting
Comments and suggestions
Little or no product or product is multi-banded
Pipetting error or missing reagent Repeat the PCR. Check the concentrations and storage conditions of reagents, including primers and dNTP mix.
Suboptimal PCR cycling conditions Using the same cycling conditions, repeat the PCR using Q-Solution.
Primer concentration not optimal or primers degraded
Repeat the PCR with different primer concentrations from 0.10.5 M of each primer (in 0.1 M increments). In particular, when performing highly sensitive PCR, check for possible degradation of the primers on a denaturing polyacrylamide gel.
-
BRO PCR beginner hints 05/2013 Sample & Assay Technologies 11
PCR troubleshooting
Comments and suggestions
Problems with starting template Check the concentration, storage conditions, and quality of the starting template. If necessary, make new serial dilutions of template nucleic acid from stock solutions and repeat the PCR.
Mg2+ concentration not optimal Perform PCR with different final concentrations of Mg2+ from 1.55.0 mM (in 0.5 mM increments) using a 25 mM MgCl2 solution.
Enzyme concentration too low Use 2.5 units of Taq DNA Polymerase per 100 l reaction.
Incorrect annealing temperature or time Decrease annealing temperature by 2C increments. Annealing time should be between 30 and 60 s. Difficulties in determining the optimal annealing temperature can often be overcome by performing touchdown PCR.
Incorrect denaturation temperature or time Denaturation should be at 94C for 3060 s. or time Ensure that a prolonged initial denaturation is performed as described in the protocols.
Hot start may be necessary Try using the hot-start procedure supplied with QIAGEN Taq DNA Polymerase, or for greater specificity, try using HotStarTaq DNA Polymerase.
Primer design not optimal Review primer design
PCR overlaid with mineral oil when using a thermal cycler with a heated lid
When performing PCR in a thermal cycler using a thermal cycler with a heated lid that is switched on, do not overlay the PCR samples with mineral oil, as this may decrease the yield of PCR product.
Product is smeared
Hot start may be necessary Try using the hot-start procedure supplied with QIAGEN Taq DNA Polymerase, or for greater specificity, try using HotStarTaq DNA Polymerase.
-
12 www.qiagen.com BRO PCR beginner hints 05/2013
PCR troubleshooting
Comments and suggestions
Too much starting template Check the concentration and storage conditions of the starting template. Make serial dilutions of template nucleic acid from stock solutions. Perform PCR using serial dilutions.
Carry-over contamination If the negative-control PCR (without template DNA) shows a PCR product or a smear, exchange all reagents. Use disposable tips containing hydrophobic filters to minimize cross-contamination. Set up all reaction mixtures in an area separate from that used for DNA preparation or PCR product analysis.
Enzyme concentration too high Use 2.5 units of Taq DNA Polymerase per 100 l reaction.
Too many cycles Reduce the number of cycles in increments of 3 cycles.
Mg2+ or primer concentration/design not optimal or primers degraded
See above section for these problems.
PCR of long fragments from genomic DNA Follow the specific protocols provided for amplification of long PCR products.
-
BRO PCR beginner hints 05/2013 Sample & Assay Technologies 13
Agarose gel analysis
Agarose gel analysis enables quick and easy quantification of DNA,
especially for small DNA fragments (such as PCR products). As little
as 20 ng DNA can be detected by agarose gel electrophoresis with
ethidium bromide staining. The DNA sample is run on an agarose gel
alongside known amounts of DNA of the same or a similar size. The
amount of sample DNA loaded can be estimated by comparison of the
band intensity with the standards either visually or using a scanner or
imaging system. Be sure to use standards of roughly the same size as
the fragment of interest to ensure reliable estimation of the DNA quantity,
since large fragments interchelate more dye than small fragments and
give a greater band intensity.
CoralLoad PCR Buffer, included in all QIAGEN PCR kits, can be used to
directly load the PCR reaction onto an agarose gel separate addition
of a gel loading buffer is not required. CoralLoad PCR Buffer provides
the same high PCR specificity and minimal reaction optimization as the
conventional QIAGEN PCR Buffer. Additionally, it contains two marker
dyes an orange dye and a red dye that facilitate estimation of
DNA migration distance and optimization of agarose gel run time
(Figure 5). The buffer ensures improved pipetting visibility and enables
direct loading of PCR products onto a gel, for enhanced convenience.
More precise agarose gel quantification can be achieved by densitometric
measurement of band intensity and comparison with a standard curve
generated using DNA of a known concentration. In most experiments the
effective range for comparative densitometric quantification is between
20 and 100 ng.
A B
Figure 5. CoralLoad PCR Buffer. The buffer contains gel-tracking dyes for easier pipetting, enabling immediate gel loading of PCR samples and easy visualization of DNA migration.
B
A
Tip: The amount of DNA used for densitometric quantification should fall within the linear range of the standard curve.
-
14 www.qiagen.com BRO PCR beginner hints 05/2013
Running an agarose gel
Agarose gel electrophoresis allows analysis of DNA fragments between 0.1 and 25 kb
(e.g., genomic DNA digested with a frequently cutting restriction endonuclease), while pulse-
field gel electrophoresis enables analysis of DNA fragments up to 10,000 kb (e.g., undigested
genomic DNA or genomic DNA digested with rare cutting restriction endonucleases). The amount
of genomic DNA loaded onto a gel depends on the application, but in general, loading of too
much DNA should be avoided as this will result in smearing of the DNA bands on the gel.
Gel loading buffer must be added to the samples before loading and serves three main purposes:
To increase the density of the samples to ensure that they sink into the wells on loading
To add color to the samples through use of dyes such as bromophenol blue or xylene cyanol,
facilitating loading
To allow tracking of the electrophoresis due to co-migration of the dyes with DNA fragments
of a specific size
Molecular-weight markers should always be included on a gel to enable analysis of DNA fragment
sizes in the samples.
Preparation of samples1. Add 1 volume of gel loading buffer to 6 volumes DNA sample and mix.
Samples should always be mixed with gel loading buffer prior to loading on a gel.
Ensure that no ethanol is present in the samples, as this will cause samples to float out of the
wells on loading.
Tip: Do not use sample volumes close to the capacity of the wells, as
samples may spill over into adjacent wells during loading.
Tip: Be sure that all samples have the same buffer composition. High
salt concentrations, for example in some restriction buffers, will
retard the migration of the DNA fragments.
Tip: If CoralLoad is used, gel loading buffer is not required, as the
CoralLoad performs this job!
-
BRO PCR beginner hints 05/2013 Sample & Assay Technologies 15
Agarose gel electrophoresis1. Apply samples in gel loading buffer to the wells of the gel.
Prior to sample loading, remove air bubbles from the wells by rinsing them with
electrophoresis buffer.
2. Connect the electrodes so that the DNA will migrate towards the anode (positive electrode).
3. Turn on the power supply and run the gel at 170 V with a switch interval of 540 s until the
dyes have migrated an appropriate distance. This will depend on the size of DNA being
analyzed, the concentration of agarose in the gel, and the separation required.
Tip: Make sure that the entire gel is submerged in the electrophoresis
buffer.
Tip: To load samples, insert the pipet tip deep into the well and expel
the liquid slowly. Take care not to break the agarose with the
pipet tip.
Tip: Once samples are loaded, do not move the gel tray/tank as this
may cause samples to float out of the wells.
Tip: Be sure to always include at least one lane of appropriate
molecular-weight markers.
Tip: Electrophoresis apparatus should always be covered to protect
against electric shocks.
Tip: Avoid use of very high voltages which can cause trailing and
smearing of DNA bands in the gel, particularly with high-
molecular-weight DNA.
Tip: Monitor the temperature of the buffer periodically during the run.
If the buffer becomes heated, reduce the voltage.
Tip: Melting of an agarose gel during the electrophoresis is a sign that
the buffer may have been incorrectly prepared or has become
exhausted during the run.
Tip: For very long runs, e.g., overnight runs, use a pump to recycle
the buffer.
-
16 www.qiagen.com BRO PCR beginner hints 05/2013
Pulse-field gel electrophoresis
1. Apply samples in gel loading buffer to the wells of the gel.
2. Connect the electrodes so that the DNA will migrate towards the anode (positive electrode).
3. Turn on the power supply and run the gel at 170 V with a switch interval of 540 s until the
dyes have migrated an appropriate distance. This will depend on the size of DNA being
analyzed, the concentration of agarose in the gel, and the separation required.
Tip: Monitor the temperature of the buffer periodically during the
run. If the buffer becomes overheated, reduce the voltage.
Tip: Melting of an agarose gel during the electrophoresis is a sign
that the buffer may have been incorrectly prepared or has
become exhausted during the run.
Tip: For very long runs, e.g., overnight runs, use a pump to recycle
the buffer.
Tip: Pulse-field gel electrophoresis uses high voltages, so TBE buffer,
which has greater buffering capacity than TAE buffer, should be
used.
Tip: Prior to sample loading, remove air bubbles from the wells by
rinsing them with electrophoresis buffer.
Tip: Make sure that the entire gel is submerged in the running buffer.
Tip: To load samples, insert the pipet tip deep into the well and
expel the liquid slowly. Take care not to break the agarose with
the pipet tip.
Tip: Once samples are loaded, do not move the gel tray/tank as this
may cause samples to float out of the wells.
Tip: Be sure to always include at least one lane of appropriate
molecular-weight markers.
Tip: Electrophoresis apparatus should always be covered to protect
against electric shocks.
-
BRO PCR beginner hints 05/2013 Sample & Assay Technologies 17
QIAGEN solutions for gel electrophoresis
Visual analysis of the gel
Staining
To allow visualization of the DNA samples, agarose gels are stained with an appropriate dye,
e.g., QIAGENs Coral Load PCR Buffer or Gel Pilot DNA Loading Dye. GelPilot DNA Loading
Dye is a high-quality gel-loading buffer for analysis of DNA samples using electrophoresis.
GelPilot DNA Loading Dye contains 3 different marker dyes (bromophenol blue, xylene cyanol,
and orange G) for reliable estimation of DNA migration distance and subsequent optimization of
gel run time.
One other common dye is the intercalating fluorescent dye ethidium bromide, which can be
added either before or after the electrophoresis.
Addition of ethidium bromide prior to electrophoresis add ethidium bromide at a
concentration of 0.5 g/ml to the melted and subsequently cooled agarose, that is, just before
pouring the gel. Mix the agaroseethidium bromide solution well to avoid localized staining.
Addition of ethidium bromide after electrophoresis soak the gel in a 0.5 g/ml solution of
ethidium bromide (in water or electrophoresis buffer) for 3040 minutes.
Tips for handling ethidium bromide:
Stock solutions of ethidium bromide (generally 10 mg/ml) should be stored at 4C in a dark
bottle or bottle wrapped in aluminum foil
Rinse the gel with buffer or water before examining it to remove excess ethidium bromide
Staining buffer can be saved and re-used
Gel Pilot Agarose Products for separation
of nucleic acid fragments by electrophoresis
Gel Pilot DNA Molecular Weight Markers
for easy and accurate sizing of DNA fragments
Gel Pilot DNA Loading Dye for safe and
convenient loading and tracking of DNA
samples on electrophoretic gels
Note: Ethidium bromide is a powerful mutagen and is very toxic. Wear gloves and take appropriate safety precautions when handling. Use of nitrile gloves is recommended as latex gloves may not provide full protection. After use, ethidium bromide solutions should be decontaminated as described in commonly used manuals.
-
18 www.qiagen.com BRO PCR beginner hints 05/2013
Tip: UV light can damage the eyes and skin. Always wear suitable eye and face protection when working with a UV light source.
Tip: UV light damages DNA. If DNA fragments are to be extracted from the gel, use a lower intensity UV source if possible and minimize exposure of the DNA to the UV light.
Avoid the use of ethidium bromide entirely by using CoralLoad PCR Buffer, found in the following QIAGEN kits:
QIAGEN Multiplex PCR Plus Kit
QIAGEN Fast Cycling PCR Kit
QIAGEN LongRange PCR Kit
HotStarTaq Plus DNA Polymerase
HotStarTaq Plus Master Mix Kit
VisualizationEthidium bromideDNA complexes display increased fluorescence compared to the dye in
solution. This means that illumination of a stained gel under UV light (254366 nm) allows bands
of DNA to be visualized against a background of unbound dye. The gel image can be recorded
by taking a Polaroid photograph or using a gel documentation system.
Frequently asked questions
Why does my DNA sample float out of the slot when loading it onto an agarose gel?
DNA fragments purified with the QIAGEN DNA cleanup systems, (e.g., the QIAquick PCR
Purification Kit, the MinElute Reaction Cleanup Kit, the QIAEX II Gel Extraction Kit, etc.) may
float out of the loading wells of agarose gels due to residual ethanol carried over from the wash
step with Buffer PE (despite the addition of glycerol-containing loading buffer).
Use any of the following options to remove residual ethanol from the eluate:
Re-purify the sample using a QIAquick or MinElute column or QIAEX II resin
Incubate the eluate at 56C for 10 min to evaporate the ethanol
Dry down the sample in a vacuum centrifuge, and resuspend the pellet in a small volume of
sterile water
How should gels be cast with the GelPilot Agarose so that optimal resolution is achieved?
When using the GelPilot Agarose, gels should be cast 34 mm thick for optimal resolution of DNA
fragments. We also recommend the use of a thin comb (1 mm) to obtain sharper DNA bands.
Taq DNA Polymerase
Taq PCR Core Kit
TopTaq DNA Polymerase
TopTaq Master Mix Kit
-
BRO PCR beginner hints 05/2013 Sample & Assay Technologies 19
How much DNA should be loaded per well of an agarose gel?
The amount of DNA per well is variable. The least amount of DNA that can be detected with
ethidium bromide is 10 ng. DNA amounts of up to 100 ng per well will result in a sharp,
clean band on an ethidium-bromidestained gel. We recommend using GelPilot Agarose for
separation of amplified products using agarose gel electrophoresis.
What voltage should be used to run an agarose gel with the GelPilot Agarose?
We recommend running agarose gels at 410 volts/cm under horizontal electrophoretic
conditions. Higher voltage may result in band streaking, while lower voltage may result in reduced
mobility of small (
-
20 www.qiagen.com BRO PCR beginner hints 05/2013
Does QIAGEN have protocols for multiple extractions of DNA fragments from agarose gels?
Yes. Follow the Supplementary Protocol High-throughput gel extractions using the QIAquick 96
PCR Purification Kit (QQ03). Contact QIAGEN Technical Services for this protocol.
My sample does not give a fluorescent signal. How do I know whether this is because the PCR did
not work or because the target is not expressed?
Use a control sample in which the gene of interest is definitely expressed. PCR products that span
the region to be amplified in the real-time experiment can also be used as a positive control.
Check by agarose gel electrophoresis that the amplification reaction was successful. The quality
of the starting template and the integrity of the reagents can be determined by amplifying a
housekeeping gene, such as GAPDH or HPRT.
* Efficient separation of PCR products differing in size by about 20 bp is usually possible using standard molecular-biologygrade agarose. For separation of fragments that differ in size by less than 20 bp, we recommend using high-resolution agarose, for example MetaPhor agarose (FMC Bioproducts). For more information, visit www.cambrex.com.
Please see the QIAGEN Multiplex PCR Handbook for additional information and for details on successful multiplex PCR using the QIAGEN Multiplex PCR Kit.
Maximum size of fragments Concentration of agarose
>200 bp
2000 bp 1.3%>100200 bp 1000 bp 1.41.6%
>50100 bp 750 bp 1.72.0%
2050 bp 500 bp 2.53.0%
-
BRO PCR beginner hints 05/2013 Sample & Assay Technologies 21
Cleanup
DNA cleanupOne of the most common tasks in molecular biology is cleaning up nucleic acids from varied matrices to remove buffer salts,
enzymes, or other substances that may affect downstream applications, such as cloning, sequencing, microarray analysis,
or amplification. There are 3 main areas of DNA cleanup:
Cleanup from enzymatic reactions, e.g., PCR
Nucleotide removal
Gel extraction and cleanup
A number of cleanup kits are available for different starting samples and downstream application needs. QIAquick and
MinElute kits contain a silica membrane assembly for binding of DNA in high-salt buffer and elution with low-salt buffer or
water. The purification procedure removes primers, nucleotides, enzymes, mineral oil, salts, agarose, ethidium bromide,
and other impurities from DNA samples (Figure 6, next page). Silica-membrane technology eliminates the problems and
inconvenience associated with loose resins and slurries. Specialized binding buffers are optimized for specific applications
and promote selective adsorption of DNA molecules within particular size ranges.
Cleanup solutions from QIAGEN:
QIAquick PCR Purification Kit for purification of up to 10 g PCR products >100 bp. DNA
of up to 10 kb is purified using a simple and fast bind-wash-elute procedure and an elution
volume of 3050 l.
QIAquick Gel Extraction Kit for purification of DNA fragments from gels (up to 400 mg
slices) or enzymatic reactions. DNA ranging from 70 bp to 10 kb is purified using a simple
and fast bind-wash-elute procedure and an elution volume of 3050 l.
QIAquick Nucleotide Removal Kit for up to 10 g oligonucleotide (1740mers) and DNA
(40 bp to 10 kb) cleanup from enzymatic reactions. The process uses just three easy steps!
MinElute PCR Purification Kit for purification of up to 5 g PCR products (70 bp to 4 kb) in
low elution volumes using a very simple procedure.
MinElute Gel Extraction Kit for purification of DNA fragments of 70 bp 4 kb from up to
400 mg gel slices. The spin columns are designed to allow elution in very small volumes (as
little as 10 l), delivering high yields of highly concentrated DNA.
MinElute Reaction Cleanup Kit for cleanup of up to 5 g DNA (70 bp to 4 kb) from
enzymatic reactions. The kit enables very low elution volumes and uses a fast procedure with
easy handling.
QIAEX II Gel Extraction Kit for purification of DNA fragments (40 bp to 50 kb) from gels
and solutions. QIAEX II Suspension is added to solutions or solubilized agarose gel slices and
binds DNA in the presence of chaotropic salts before washing and elution.
-
22 www.qiagen.com BRO PCR beginner hints 05/2013
Maaa bbbM
2000 bp
500 bp
20 mer100 bp
Figure 6. Analysis of PCR products before (b) and after (a) purification using the QIAquick PCR Purification Kit. Samples were analyzed on a 1% TAE agarose gel. M: markers.
The advantages of silica-membrane technology include:
Yielding high-purity nucleic acids for use in most downstream
applications
Fast and inexpensive
No silica-slurry carry over, no alcohol precipitation
QIAGENs QIAquick and MinElute cleanup system use a simple bind-
wash-elute procedure (Figure 7). Sample mixtures are applied to the
spin column (in some applications, this includes a buffer that contains a
pH indicator; allowing easy determination of the optimal pH for DNA
binding see Figure 8).
Nucleic acids adsorb to the silica membrane in the high-salt conditions
provided by the buffer. Impurities are washed away and pure DNA is
eluted with a small volume of low-salt buffer provided or water, ready to
use in all subsequent applications.
Vacuum
Vacuum
QIAquick and MinElute Procedure
PCR or otherenzymatic reaction orsolubilized gel slice
Pure DNA fragment
QIAcube
From solutions 5minFrom gels 15min
Figure 7. QIAquick and MinElute procedure. In addition to spin columns, manual and automated high-throughput kits are also available.
Optimal pH pH too High
Figure 8. pH Indicator Dye. Indicator enables easy checking of the optimal pH. Indicator dye in solubilization and binding buffers (Buffer QG and Buffer PB) identifies optimal pH for DNA binding.
-
BRO PCR beginner hints 05/2013 Sample & Assay Technologies 23
DNA yield and concentrationDNA yield depends on the following 3 factors:
Elution buffer volume
How the buffer is applied to the column
Incubation time of the buffer on the column
To completely cover the QIAquick/MinElute membrane, use 100200 l elution buffer. This ensures
maximum yield, even when not applied directly to the center of the membrane. Elution with
50 l requires the buffer to be added directly to the center of the membrane, and if elution is done
with the minimum recommended volume of 30 l, an additional 1 minute incubation is required
for optimal yield. DNA will be up to 1.7 times more concentrated if the column is incubated for
1 minute with 30 l of elution buffer, than if it is eluted in 50 l without incubation.
The kits vary depending on the type of reaction and DNA fragment size (e.g., PCR products, gel
extraction, enzymatic reactions, nucleotide removal, dye terminator removal) and the required
elution volume.
Tip: Depending on the application, fragment size, etc. it is advisable to use a specialized kit for optimal results. Please consult Tables 1 and 2 to find the kit that best meets your needs.
QIAquick PCR Purication Kit QIAquick Nucleotide Removal Kit QIAquick Gel Extraction Kit
For DNA cleanup from thefollowing reactions:
YES no noYES
cDNA synthesisAlkaline phosphatase YES YES
YESKinase:DNase, nuclease digestion YES YES
no YES noYES
OligonucleotidesDNA fragments YES YES
YES YES YESYES
Nick translationLigation YES YES
YESPCRRandom priming
no noYES YES YES
YES YES YES
YESTailing:Restriction digestion YES YES
DNA fragments
Recovery:Specications
Oligonucleotides no YES no
100 bp 10 kb 40 bp 10 kb 70 bp 10 kb
dsDNAOligonucleotides 1740mers
Removal:
-
24 www.qiagen.com BRO PCR beginner hints 05/2013
Frequently asked questions
How can I ensure that I have the right pH?
The binding buffer contains a pH indicator, allowing easy determination of the optimal pH for
DNA binding (see Figure 8).
Binding buffer PB and binding and solubilization buffer QG are specially optimized for use with
the QIAquick silica membrane. Buffer QG contains an integrated pH Indicator, while an optional
pH Indicator can be added to Buffer PB allowing easy determination of the optimal pH for DNA
binding. DNA adsorption requires a pH 7.5, and the pH Indicator in the buffers will appear
yellow in this range. If the pH is >7.5, which can occur if during agarose gel electrophoresis, the
electrophoresis buffer had been used repeatedly or incorrectly prepared, or if the buffer used in an
enzymatic reaction is strongly basic and has a high buffering capacity, the binding mixture turns
orange or violet. This means that the pH of the sample exceeds the buffering capacity of Buffer
PB or QG and DNA adsorption will be inefficient. In these cases, the pH of the binding mixture
can easily be corrected by addition of a small volume of 3 M sodium acetate, pH 5.0, before
proceeding with the protocol.
DNA cleanup application Elution volume20 l
10 l
Gel extraction
3050 l
10 l
QIAquick PCRPurication Kits
QIAquick PCRPurication Kits
QIAEX II GelExtraction Kit
MinElute PCRPurication Kit
MinElute PCRPurication Kit
MinElute 96 UFPCR Purication Kit
MinElute 96 UFPCR Purication Kit
QIAquick GelExtraction Kit
QIAquick GelExtraction Kit
QIAquick GelExtraction Kit
QIAEX II GelExtraction Kit
QIAEX II GelExtraction Kit
QIAEX II GelExtraction Kit
QIAEX II GelExtraction Kit
MinElute GelExtraction Kit
MinElute GelExtraction Kit
QIAquick DNACleanup System
QIAquick DNACleanup System
QIAEX II GelExtraction Kit
MinElute ReactionCleanup Kit
MinElute ReactionCleanup Kit
QIAquickNucleotideRemoval Kit
QIAquickNucleotideRemoval Kit
QIAquickNucleotideRemoval Kit
n.a.30200 l
Cleanup fromenzymatic reactions
Nucleotide removal
n.a.: Not applicable.
Table 2. Cleanup overview
-
BRO PCR beginner hints 05/2013 Sample & Assay Technologies 25
What is the small band below my fragment of interest on an agarose gel after DNA cleanup using
QIAquick?
Occasionally, DNA fragments eluted from the silica matrix of QIAquick, MinElute, or QIAEX
II Kits will contain denatured single-stranded DNA (ssDNA), appearing as a smaller band on
an analytical gel. Under certain conditions, chaotropic agents (present in all silica-based DNA
purification methods) can denature DNA fragments. This is a rare event that may be influenced by
sequence characteristics such as the presence of inverted repeats or AT-rich stretches.
Because salt and buffering agents promote renaturation of DNA strands, the following tips are
recommended:
Use the eluted DNA to prepare your downstream enzymatic reaction, but omit the enzyme.
Incubate the reaction mix at 95C for 2 minutes to reanneal the ssDNA, and allow the tube to
cool slowly to room temperature before adding the enzyme and proceeding
Alternatively, the DNA can be eluted from the silica-gel membrane or resin in 10 mM Tris buffer
containing 10 mM NaCl. However, the salt concentration of the eluate must then be taken into
consideration in downstream applications.
Can I use the QIAquick PCR Purification Kit for restriction enzyme cleanup?
Yes. The QIAquick PCR Purification Kit has been used to clean up fragments between 100 bp and
10 kb from a wide range of enzymatic reactions, removing salts, buffers, enzymes, nucleotides,
and primers smaller than 40 nucleotides. Reactions that can be cleaned up with the QIAquick PCR
Purification Kit include restriction digests, random priming, ligase, kinase, phosphatase, nuclease,
nick translation, and cDNA synthesis reactions.
Do you have information about the cleanup of single-stranded DNA (ssDNA) with QIAquick
columns?
As a rule of thumb, single-stranded DNA binds to silica with approximately half the affinity of
a double-stranded DNA fragment of the same length under the buffer conditions used in the
QIAquick and MinElute Kits. Even though no systematic experimental data exists, we expect
thatrecovery of ssDNA fragments of approximately 200 nucleotides and belowwill not be very
efficient after cleanup using the QIAquick PCR Purification Kit or MinElute PCR Purification Kit.
By comparison, it should be possible to purify fragments longer than 140 nucleotides using the
QIAquick Gel Extraction Kit.
Note that recovery of single strand DNA is influenced to some degreealso by factors such asbase
composition and secondary structure. It has to be determined empirically by the researcher if
cleanup of single-stranded DNA with QIAquick columns yields satisfactory results.
-
26 www.qiagen.com BRO PCR beginner hints 05/2013
Are Buffer PB of the QIAquick PCR Purification Kit and Buffer QG of the QIAquick Gel Extraction
Kit interchangeable?
Buffer PB of the QIAquick PCR Purification Kit cannot be used to extract DNA from agarose gels.
However, Buffer QG of the QIAquick Gel Extraction Kit can be used to remove salt and proteins
from enzymatic reactions by adding 3 volumes of Buffer QG and 1 volume of isopropanol to the
reaction and proceeding with step 6 of the Gel Extraction Spin Protocol in the QIAquick Spin
Handbook. See the QIAquick Spin Handbookfor a list of reactions which can be cleaned up with
the various QIAquick kits.
I bound an 11 kb DNA fragment to a QIAquick column; is it completely lost?
Larger DNA fragments bind more tightly to the QIAquick columns. It is difficult to predict whether
a DNA fragment larger than 10 kb can be efficiently recovered, because this depends on base
composition as well as fragment size. If the fragment is only a few kb larger than the 10 kb limit,
it can be helpful to heat the elution buffer EB to 60C and let it incubate on the column for a few
minutes before centrifuging. However, please note that it will become less likely to recover your
sample the larger the fragment size is. As we cannot guarantee recovery of fragments larger than
the maximum cutoff size, we do not recommend purifying such fragments using QIAquick Kits.
The QIAEX II Kit can be used to extract DNA fragments up to 50 kb from agarose or polyacrylamide
gels.
Cleanup troubleshooting
Comments and suggestions
Low or no recovery
Buffer PE did not contain ethanol Ethanol must be added to Buffer PE (concentrate) before use. Repeat procedure with correctly prepared Buffer PE.
Inappropriate elution buffer DNA will only be eluted efficiently in the presence of low-salt buffer (e.g., Buffer EB: 10 mM TrisCl, pH 8.5) or water.
Elution buffer incorrectly dispensed Add elution buffer to the center of the QIAquick membrane to ensure that the buffer completely covers the membrane. This is particularly important when using small elution volumes (30 l).
-
BRO PCR beginner hints 05/2013 Sample & Assay Technologies 27
Cleanup troubleshooting
Comments and suggestions
QIAquick Gel Extraction Kit only
Gel slice incompletely solubilized After addition of Buffer QG to the gel slice, mix by vortexing the tube every 23 min during the 50C incubation. DNA will remain in any undissolved agarose.
pH of electrophoresis buffer too high (binding mixture turns orange or violet)
The electrophoresis buffer has been repeatedly used or incorrectly prepared, resulting in a sample pH that exceeds the buffering capacity of Buffer QG and leads to inefficient DNA binding. Add 10 l of 3 M sodium acetate, pH 5.0, to the sample and mix. The color of the mixture will turn yellow indicating the correct pH for DNA binding. Even for binding mixtures with only small color changes (slight orange color), add the 10 l sodium acetate.
Gel slice was too large 7080% recovery can only be obtained from 400 mg gel (>400 mg) slice per QIAquick column. For gel slices >400 mg, use multiple QIAquick columns.
QIAquick PCR Purification Kit only
Insufficient/no product PCR Estimate DNA recovery by running 10% of PCR product before and after purification on an agarose gel.
QIAquick Gel Extraction Kit and QIAquick PCR Purification Kit only
Cloudy and gelatinous appearance of sample mixture after addition of isopropanol
This may be due to salt precipitation, and will disappear upon mixing the sample. Alternatively, the gel slice may not be completely solubilized. In this case, apply the mixture to the QIAquick column, centrifuge, and then add 0.5 ml Buffer QG to the column. Let stand for 1 min at room temperature (1525C), and then centrifuge and continue with the procedure. This additional wash will solubilize remaining agarose.
Binding mixture turns orange or violet The pH in the sample exceeds the buffer capacity of Buffer QG or PB respectively. Add 20 l of 3 M sodium acetate, pH 5.0, to the sample and mix. The color of the mixture will turn yellow indicating the correct pH for DNA binding. Even for samples with slight color changes (orange color), add 10 l sodium acetate.
-
28 www.qiagen.com BRO PCR beginner hints 05/2013
Cleanup troubleshooting
Comments and suggestions
DNA does not perform well (e.g., in downstream ligation reactions)
Salt concentration in eluate too high Modify the wash step by incubating the column for 5 min at room temperature after adding 750 l of Buffer PE, then centrifuge.
Eluate contains residual ethanol Ensure that the wash flow-through is drained from the collection tube and that the QIAquick column is then centrifuged at 17,900 x g (13,000 rpm) for an additional 1 min.
QIAquick Gel Extraction Kit only
Eluate contaminated with agarose The gel slice is incompletely solubilized or weighs >400 mg. Repeat procedure, including the optional Buffer QG column-wash step.
QIAquick PCR Purification Kit only
Eluate contains primerdimers Primerdimers formed are >20 bp and are not completely removed.After the binding step, wash the QIAquick column with 750 l of a 35% guanidine hydrochloride aqueous solution (35 g in 100 ml). Continue with the Buffer PE wash step and the elution step as in the protocol.
Eluate contains denatured ssDNA, which appears as a smaller smeared band on an analytical gel
Use the eluted DNA to prepare the subsequent enzymatic reaction but omit the enzyme. To reanneal the ssDNA, incubate the reaction mixture at 95C for 2 min, and allow the tube to cool slowly to room temperature. Add the enzyme and proceed as usual. Alternatively, the DNA can be eluted in 10 mM Tris buffer containing 10 mM NaCl. The salt and buffering agent promote the renaturation of DNA strands. However, the salt concentration of the eluate must then be considered for subsequent applications.
-
BRO PCR beginner hints 05/2013 Sample & Assay Technologies 29
Cleanup troubleshooting
Comments and suggestions
DNA does not perform well (e.g., in downstream ligation reactions)
Salt concentration in eluate too high Modify the wash step by incubating the column for 5 min at room temperature after adding 750 l of Buffer PE, then centrifuge.
Eluate contains residual ethanol Ensure that the wash flow-through is drained from the collection tube and that the QIAquick column is then centrifuged at 17,900 x g (13,000 rpm) for an additional 1 min.
QIAquick Gel Extraction Kit only
Eluate contaminated with agarose The gel slice is incompletely solubilized or weighs >400 mg. Repeat procedure, including the optional Buffer QG column-wash step.
QIAquick PCR Purification Kit only
Eluate contains primerdimers Primerdimers formed are >20 bp and are not completely removed.After the binding step, wash the QIAquick column with 750 l of a 35% guanidine hydrochloride aqueous solution (35 g in 100 ml). Continue with the Buffer PE wash step and the elution step as in the protocol.
Eluate contains denatured ssDNA, which appears as a smaller smeared band on an analytical gel
Use the eluted DNA to prepare the subsequent enzymatic reaction but omit the enzyme. To reanneal the ssDNA, incubate the reaction mixture at 95C for 2 min, and allow the tube to cool slowly to room temperature. Add the enzyme and proceed as usual. Alternatively, the DNA can be eluted in 10 mM Tris buffer containing 10 mM NaCl. The salt and buffering agent promote the renaturation of DNA strands. However, the salt concentration of the eluate must then be considered for subsequent applications.
Discover our complete range of PCR products at www.qiagen.com.For up-to-date licensing information and product-specific disclaimers, see the respective QIAGEN
kit handbook or user manual. QIAGEN kit handbooks and user manuals are available at www.
qiagen.com or can be requested from QIAGEN Technical Services or your local distributor.
Trademarks: QIAGEN, QIAEX, QIAquick, BioRobot, CoralLoad, GelPilot, HotStarTaq, Q-Solution, TopTaq, Type-it (QIAGEN Group); Eppendorf (Eppendorf AG); Parafilm (Bemis Company, Inc.); MetaPhor (FMC Bioproducts). Registered names, trademarks, etc. used in this document, even when not specifically marked as such, are not to be considered unpro-tected by law.
2013 QIAGEN, all rights reserved.
-
1075
777
05
/201
3
www.qiagen.com
Sample & Assay Technologies