1 © Nokia Siemens Networks Flexi FCM & FSP LTE SW installation check active OS check active bootline on FCM OSE check Linux version on FCM Linux flash Linux to the inactive FCM bootline Install the Application SW to FCM check active OS upgrade needed Install the Application SW to FCM upgrade not needed START R&D package installation check active bootline on FSP1 flash Linux to the inactive FSP1 bootline Install Application SW to FSP1 flash Linux to the other (now inactive) FSP1 bootline repeat these steps for FSP2 and FSP3 if existing repeat this step for FSP2 and FSP3 if existing Start puttibatti SW installation check Linux version on FSPs upgrade needed upgrade not needed Install Application SW to FSP1 Install Application SW to FSP2 & FSP3 if existing Start puttibatti SW installation flash Linux to the other (now inactive) FCM bootline steps depending on the FSMx version FSMD: FSP1+3 FSME: FSP1+2+3

description

Flexi FCM&FSP LTE SW Installation

Transcript of 31_Flexi FCM&FSP LTE SW Installation_v1.1

Page 1: 31_Flexi FCM&FSP LTE SW Installation_v1.1

1 © Nokia Siemens Networks

Flexi FCM & FSP LTE SW installation

check active

OS

check active bootline on FCM

OSE

check Linux version on

FCM

Linux

flash Linux to the inactive FCM bootline

Install the Application SW to FCMcheck active

OS

upgrade needed

Install the Application SW to FCM

upgrade not needed

START R&D package

installation

check active bootline on FSP1

flash Linux to the inactive FSP1 bootline

Install Application SW to FSP1

flash Linux to the other (now inactive) FSP1 bootline

repeat these steps for FSP2 and FSP3

if existing

repeat this step for FSP2and FSP3 if existing

Start puttibatti SW installation

check Linux version on

FSPs

upgradeneeded

upgradenot needed

Install Application SW to FSP1

Install Application SW to FSP2 & FSP3 if existing

Start puttibatti SW installation

flash Linux to the other (now inactive) FCM bootline

steps depending on the FSMx versionFSMD: FSP1+3FSME: FSP1+2+3

Page 2: 31_Flexi FCM&FSP LTE SW Installation_v1.1

2 © Nokia Siemens Networks

Flexi FCM & FSP LTE SW installation

First puttibattiinstallation?

Run flash_erase batch files for FCM and FSPs and then copy R&D package

application SW to FCM and FSPs

Yes

Run phase 3 batch files for

FCM and FSPs

No

Is LN1.0_18.32-2 or newer installed

Start puttibattipackage

installation

FCM and FSP SW upgrade finished

Go back to R&D package installation and install a newer R&D software

package

NoYes

Yes

Run step 1 batch files

Run step 2 batch files

Perform passive file system format

Run step 3 batch files

FCM and FSP SW upgrade finished