05 t1 y t2 contrast

43
HOME in conclusion: T1 relates to magnetisation T2 relates to signal signal generation

Transcript of 05 t1 y t2 contrast

Page 1: 05 t1 y t2 contrast

THOME

in conclusion:

• T1 relates to magnetisation

• T2 relates to signal

signal generation

Page 2: 05 t1 y t2 contrast

THOME

nuclei, protons and spins

longitudinal relaxation T1

transverse relaxation T2

excitation and relaxation

relation between T1 and T2

signal generation

Page 3: 05 t1 y t2 contrast

THOME

0time

100

Longitudinal and TransverseRelaxation:

90o

signal generationrelation between T1 and T2

Page 4: 05 t1 y t2 contrast

THOME

0time

100

Longitudinale and TransversaleRelaxation: at the same moment

90o

magnetisation

signal

signal generationrelation between T1 and T2

Page 5: 05 t1 y t2 contrast

THOME

short T1

0time

100

90o 90o

signal generationrelation between T1 and T2

Page 6: 05 t1 y t2 contrast

THOME

short T1

short T2

0time

100

90o 90o

signal generationrelation between T1 and T2

Page 7: 05 t1 y t2 contrast

THOME

long T1

0time

100

90o 90o

signal generationrelation between T1 and T2

Page 8: 05 t1 y t2 contrast

THOME

long T1

long T2

0time

100

90o 90o

signal generationrelation between T1 and T2

Page 9: 05 t1 y t2 contrast

THOME

0time

100

90o

repetition time

TR90o

signal generationrelation between T1 and T2

Page 10: 05 t1 y t2 contrast

THOME

0time

100

90o 90o

echo time

TE

signal generationrelation between T1 and T2

Page 11: 05 t1 y t2 contrast

THOME

0time

100

90o 90o

signal generationrelation between T1 and T2

Page 12: 05 t1 y t2 contrast

THOME

0time

100

90o 90o

signal generationrelation between T1 and T2

Page 13: 05 t1 y t2 contrast

THOME

0time

100

90o 90o

signal generationrelation between T1 and T2

Page 14: 05 t1 y t2 contrast

THOME

signal generationrelation between T1 and T2

T1 contrast

Page 15: 05 t1 y t2 contrast

THOME

time

90o

longitudinal relaxation = magnetisation

signal generationT1 contrast

Page 16: 05 t1 y t2 contrast

THOME

time

90o

magnetisation cannot be measured!

signal generationT1 contrast

Page 17: 05 t1 y t2 contrast

THOME

time

90o

signal generationT1 contrast

Page 18: 05 t1 y t2 contrast

THOME

time

90o 90o

signal generationT1 contrast

Page 19: 05 t1 y t2 contrast

THOME

time

90o 90o

grey

white

signal generationT1 contrast

Page 20: 05 t1 y t2 contrast

THOME

time

90o 90o

grey

white

signal generationT1 contrast

Page 21: 05 t1 y t2 contrast

THOME

time

90o 90o

grey

white

signal generationT1 contrast

Page 22: 05 t1 y t2 contrast

THOME

time

90o 90o

grey

white

signal generationT1 contrast

Page 23: 05 t1 y t2 contrast

THOME

TE 10 ms TE 30 ms TE 40 ms

TR 400 ms

signal generationT1 contrast

Page 24: 05 t1 y t2 contrast

THOME

T1 weighted images:

TR short

TE short

< 600 ms

< 25 ms

signal generationT1 contrast

Page 25: 05 t1 y t2 contrast

THOME

Fat bright

bone marrow

white matter

musclegrey

body fluids

bone

air black

grey matter

TR < 600 ms TE < 25 ms

i.v.contrast

signal generationT1 contrast

Page 26: 05 t1 y t2 contrast

THOME

signal generationT1 contrast

Page 27: 05 t1 y t2 contrast

THOME

Glioblastoma

T1 T1 with Gadolinium

signal generationT1 contrast

Page 28: 05 t1 y t2 contrast

THOME

signal generationT1 contrast

Page 29: 05 t1 y t2 contrast

THOME

T2 contrast

signal generationrelation between T1 and T2

Page 30: 05 t1 y t2 contrast

THOME

time

90o 90o

signal generationT2 contrast

Page 31: 05 t1 y t2 contrast

THOME

time

90o 90o

signal generationT2 contrast

Page 32: 05 t1 y t2 contrast

THOME

time

90o 90o

signal generationT2 contrast

Page 33: 05 t1 y t2 contrast

THOME

time

90o 90o

signal generationT2 contrast

Page 34: 05 t1 y t2 contrast

THOME

time

90o

signal generationT2 contrast

Page 35: 05 t1 y t2 contrast

THOME

time

90o

signal generationT2 contrast

Page 36: 05 t1 y t2 contrast

THOME

time

90o

signal generationT2 contrast

Page 37: 05 t1 y t2 contrast

THOME

time

90o

signal generationT2 contrast

Page 38: 05 t1 y t2 contrast

THOME

TR 2500 ms

TE 20 msTE 60 ms

TE 100 ms

TE 140 ms

signal generationT2 contrast

Page 39: 05 t1 y t2 contrast

THOME

T2 weighted images:

TR long

TE long

> 1800 ms

> 80 ms

signal generationT2 contrast

Page 40: 05 t1 y t2 contrast

THOME

signal generationT2 contrast

Page 41: 05 t1 y t2 contrast

THOME

signal generationT2 contrast

Page 42: 05 t1 y t2 contrast

THOME

T1 T1 + KM

T2

signal generationT2 contrast

Page 43: 05 t1 y t2 contrast

THOME

signal generationT2 contrast